# 30 CFR 75.1403-6 — Criteria—Self-propelled personnel carriers.

- **Chapter:** CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR
- **Subchapter:** SUBCHAPTER O—COAL MINE SAFETY AND HEALTH
- **Part:** PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES
- **Subpart:** Subpart O—Hoisting and Mantrips
- **Snapshot current through:** 2026-08-19
- **Official eCFR:** https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403-6

## Current public text

(a) Each self-propelled personnel carrier should:

(1) Be provided with an audible warning device;

(2) Be provided with a sealed-beam headlight, or its equivalent, on each end;

(3) Be provided with reflectors on both ends and sides.

(b) In addition, each track-mounted self-propelled personnel carrier should:

(1) Be provided with a suitable lifting jack and bar, which shall be secured or carried in a tool compartment;

(2) Be equipped with 2 separate and independent braking systems properly installed and well maintained;

(3) Be equipped with properly installed and well-maintained sanding devices, except that personnel carriers (jitneys), which transport not more than 5 men, need not be equipped with such sanding device;

(4) If an open type, be equipped with guards of sufficient strength and height to prevent personnel from being thrown from such carriers.

## Provenance

- Source: Electronic Code of Federal Regulations, Title 30
- Representation: Realm public-data crosswalk
- Legal status: The eCFR is an editorial compilation; consult the official source before relying on the text.