{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4801646","name":"Bridger Underground Coal Mine","status":"Abandoned and Sealed","status_date":"2024-04-15","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WY","county":"Sweetwater","nearest_town":"Rock Springs, Wyoming","operator_id":"P00648","operator_name":"Bridger Coal Company","controller_id":"C00514","controller_name":"MidAmerican Energy Holdings Company; IDACORP","district":"M6","office":"Green River WY Field Office","employees":0,"latitude":41.821389,"longitude":-108.330556},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":20319},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4801646","name":"Bridger Underground Coal Mine"},"operator":{"type":"operator","id":"P00648","name":"Bridger Coal Company"},"controller":{"type":"controller","id":"C00514","name":"MidAmerican Energy Holdings Company; IDACORP"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00514","name":"IDACORP et al"},"object":{"type":"mine","id":"4801646","name":"Bridger Underground Coal Mine"},"validFrom":"1950-01-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4801646|C00514|1950-01-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P00648","name":"Bridger Coal Company"},"object":{"type":"mine","id":"4801646","name":"Bridger Underground Coal Mine"},"validFrom":"2004-07-15","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4801646|P00648|2004-07-15|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00514","name":"IDACORP et al"},"object":{"type":"operator","id":"P00648","name":"Bridger Coal Company"},"validFrom":"2004-07-15","validTo":null,"current":true,"derived":true,"evidenceMineId":"4801646","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4801646|P00648|2004-07-15|C00514|1950-01-01|47676"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00514","name":"MidAmerican Energy Holdings Company et al"},"object":{"type":"operator","id":"P00648","name":"Bridger Coal Company"},"validFrom":"2004-07-15","validTo":null,"current":true,"derived":true,"evidenceMineId":"4801646","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4801646|P00648|2004-07-15|C00514|1950-01-01|47677"}}],"coverage":{"historyRecords":2,"edgeCount":4,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":241,"firstDate":"2004-10-06","lastDate":"2021-10-31","metrics":{"daysLost":6817,"injuries":198,"fatalities":2,"recentRows":5,"restrictedDays":2051,"contractorRecords":28},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"210716","DOCUMENT_NO":"220213160029","ACCIDENT_DT":"10/31/2021","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"28","NARRATIVE":"Employee was walking from the tailgate towards the head-gate when employee was stepping from shield 105 to shield 104 a rock fell from in-between the shields and landed on employee's foot. This caused a laceration between the two small toes on right foot and fractured the small toe.","sourceDate":"2021-10-31"},{"SOURCE_ROW_NUMBER":"176318","DOCUMENT_NO":"220212530023","ACCIDENT_DT":"08/16/2021","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Longwall operator, Chock operator, Shear operator, Plow operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Piece of coal hit employee on hand while pulling shield.","sourceDate":"2021-08-16"},{"SOURCE_ROW_NUMBER":"8598","DOCUMENT_NO":"220210890002","ACCIDENT_DT":"03/18/2021","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall from scaffolds, walkways, platforms","OCCUPATION":"Assayer, Geologist, Metallurgist, Engineer, Engineer management","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was removing the tin off of a portable building. When EE went to move EE's lanyard to a different place the tin EE was standing on gave way. The employee fell approximately 12.5ft.","sourceDate":"2021-03-18"},{"SOURCE_ROW_NUMBER":"270864","DOCUMENT_NO":"220210560017","ACCIDENT_DT":"02/16/2021","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Section foreman, Bullgang foreman, Labor foreman, Leadman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was stocking the trays on the roof bolter, when EE's hand was pinched between the mesh rack and the bolt pod. The mesh rack had been set down on an open bundle of bolts. When the plates were removed the bolts shifted allowing the mesh rack to drop down about 1 inch which was enough to pinch the employee's hand.","sourceDate":"2021-02-16"},{"SOURCE_ROW_NUMBER":"72943","DOCUMENT_NO":"220210470008","ACCIDENT_DT":"02/02/2021","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"84","NARRATIVE":"Employee was walking down the belt line when EE stepped into a water hole and twisted EE's knee","sourceDate":"2021-02-02"},{"SOURCE_ROW_NUMBER":"266614","DOCUMENT_NO":"220201770045","ACCIDENT_DT":"06/17/2020","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"D-rings left on hoses got tangled up while pulling down road, Employee went to untangle, lack of communication between driver of vehicle and employee watching cable. Employee got tangled up and drug down road way.","sourceDate":"2020-06-17"},{"SOURCE_ROW_NUMBER":"38686","DOCUMENT_NO":"220201710027","ACCIDENT_DT":"06/11/2020","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Longwall operator, Chock operator, Shear operator, Plow operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Injured employee was working on the longwall face, pulling in shields. As the shearer passed near EE's location the tailgate side drum picked up a large piece of coal, the piece of coal hit the pan and then struck employee on shoulder and foot. Employee has not been able to return to regular job duties.","sourceDate":"2020-06-11"},{"SOURCE_ROW_NUMBER":"30075","DOCUMENT_NO":"220201360011","ACCIDENT_DT":"04/15/2020","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"ELECTRICAL","ACCIDENT_TYPE":"Contact with electrical current","OCCUPATION":"Miner, NEC","NO_INJURIES":"1","DAYS_LOST":"175","NARRATIVE":"Employee had re-set electrical breaker on a belt winder. After re-setting the electrical breaker, employee reached across the control box to turn the pump on when they received an electrical shock. Employee was originally fully released to full duty but recent medical evaluation has placed them on days away from work, therefore, late reporting of this incident.","sourceDate":"2020-04-15"},{"SOURCE_ROW_NUMBER":"262446","DOCUMENT_NO":"220201060007","ACCIDENT_DT":"04/05/2020","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by powered moving object","OCCUPATION":"Miner, NEC","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Contractor was trying to lift a bolter cable in order for a skid-steer to place a pallet of plates. In doing so,the skid-steer ran over the contractors foot. Contractor was placed on restricted duty as of 04/09/2020. Contractor terminated employment as of 04/14/2020.","sourceDate":"2020-04-05"},{"SOURCE_ROW_NUMBER":"55788","DOCUMENT_NO":"220200620014","ACCIDENT_DT":"02/28/2020","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Longwall operator, Chock operator, Shear operator, Plow operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Injured miner was giving directions to another miner as they were using shield #3 to free pan blockage. Injured miner was standing under shield #4 when a piece of rock fell and hit foot. The wound required stitches to close.","sourceDate":"2020-02-28"},{"SOURCE_ROW_NUMBER":"227951","DOCUMENT_NO":"220200360009","ACCIDENT_DT":"01/31/2020","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Miner, NEC","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was carrying old scraper parts, another miner was cutting a lid from a bucket using a knife. The knife slipped as employee walked by, cutting employee's leg. Stitches were required to close the cut.","sourceDate":"2020-01-31"},{"SOURCE_ROW_NUMBER":"115896","DOCUMENT_NO":"220192970031","ACCIDENT_DT":"10/08/2019","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While building crib, employee got hand caught between 2 crib blocks.","sourceDate":"2019-10-08"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2024-04-15","lastDate":"2024-04-15","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":2563,"firstDate":"2004-11-16","lastDate":"2022-06-03","metrics":{"ss":365,"delinquent":2451,"recentRows":54,"paidPenalty":1720666.4,"proposedPenalty":2336979,"currentAssessment":1720820.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2028078","VIOLATION_NO":"9150222","ISSUE_DT":"06/03/2022","CFR_STANDARD_CD":"50.20-7(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"133.00","CURRENT_ASSESSMENT_AMT":"133.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2022-06-03"},{"SOURCE_ROW_NUMBER":"2028034","VIOLATION_NO":"9150249","ISSUE_DT":"10/26/2021","CFR_STANDARD_CD":"75.321(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"125.00","CURRENT_ASSESSMENT_AMT":"125.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-10-26"},{"SOURCE_ROW_NUMBER":"2028033","VIOLATION_NO":"9150248","ISSUE_DT":"10/20/2021","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"146.00","CURRENT_ASSESSMENT_AMT":"146.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-10-20"},{"SOURCE_ROW_NUMBER":"2028032","VIOLATION_NO":"9150247","ISSUE_DT":"10/20/2021","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"146.00","CURRENT_ASSESSMENT_AMT":"146.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-10-20"},{"SOURCE_ROW_NUMBER":"2028031","VIOLATION_NO":"9150246","ISSUE_DT":"10/19/2021","CFR_STANDARD_CD":"75.1719-4(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"187.00","CURRENT_ASSESSMENT_AMT":"187.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-10-19"},{"SOURCE_ROW_NUMBER":"2028030","VIOLATION_NO":"9150245","ISSUE_DT":"10/19/2021","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"328.00","CURRENT_ASSESSMENT_AMT":"328.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-10-19"},{"SOURCE_ROW_NUMBER":"2028029","VIOLATION_NO":"9150242","ISSUE_DT":"10/04/2021","CFR_STANDARD_CD":"75.1106-3(a)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"187.00","CURRENT_ASSESSMENT_AMT":"187.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-10-04"},{"SOURCE_ROW_NUMBER":"2028008","VIOLATION_NO":"9150183","ISSUE_DT":"08/09/2021","CFR_STANDARD_CD":"75.1722(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"187.00","CURRENT_ASSESSMENT_AMT":"187.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-08-09"},{"SOURCE_ROW_NUMBER":"2028007","VIOLATION_NO":"9150182","ISSUE_DT":"08/08/2021","CFR_STANDARD_CD":"75.1909(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"125.00","CURRENT_ASSESSMENT_AMT":"125.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-08-08"},{"SOURCE_ROW_NUMBER":"2028006","VIOLATION_NO":"9030775","ISSUE_DT":"08/03/2021","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"125.00","CURRENT_ASSESSMENT_AMT":"125.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-08-03"},{"SOURCE_ROW_NUMBER":"2028005","VIOLATION_NO":"9030774","ISSUE_DT":"07/27/2021","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"279.00","CURRENT_ASSESSMENT_AMT":"279.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-07-27"},{"SOURCE_ROW_NUMBER":"2028004","VIOLATION_NO":"8541432","ISSUE_DT":"07/11/2021","CFR_STANDARD_CD":"75.380(d)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"416.00","CURRENT_ASSESSMENT_AMT":"416.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-07-11"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":416,"firstDate":"2007-05-08","lastDate":"2022-05-23","metrics":{"appeals":0,"decisions":416,"recentRows":8,"decisionPenalty":903770.4,"originalPenalty":1547707},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"433252","VIOLATION_NO":"8540101","DOCKET_NO":"WEST 2022-0178","DECISION_DT":"05/23/2022","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"133.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2022-05-23"},{"SOURCE_ROW_NUMBER":"428544","VIOLATION_NO":"8541428","DOCKET_NO":"WEST 2022-0003","DECISION_DT":"01/18/2022","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1385.00","DECISION_PENALTY_AMT":"1385.00","JUDGE_FIRST_NAME":"Richard","JUDGE_LAST_NAME":"Manning","sourceDate":"2022-01-18"},{"SOURCE_ROW_NUMBER":"427633","VIOLATION_NO":"8540125","DOCKET_NO":"WEST 2021-0310","DECISION_DT":"12/30/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1006.00","DECISION_PENALTY_AMT":"1006.00","JUDGE_FIRST_NAME":"Richard","JUDGE_LAST_NAME":"Manning","sourceDate":"2021-12-30"},{"SOURCE_ROW_NUMBER":"427632","VIOLATION_NO":"8540124","DOCKET_NO":"WEST 2021-0310","DECISION_DT":"12/30/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"929.00","DECISION_PENALTY_AMT":"208.00","JUDGE_FIRST_NAME":"Richard","JUDGE_LAST_NAME":"Manning","sourceDate":"2021-12-30"},{"SOURCE_ROW_NUMBER":"148863","VIOLATION_NO":"8540123","DOCKET_NO":"WEST 2021-0310","DECISION_DT":"12/30/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"929.00","DECISION_PENALTY_AMT":"929.00","JUDGE_FIRST_NAME":"Richard","JUDGE_LAST_NAME":"Manning","sourceDate":"2021-12-30"},{"SOURCE_ROW_NUMBER":"148563","VIOLATION_NO":"8540127","DOCKET_NO":"WEST 2021-0310","DECISION_DT":"12/30/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"22770.00","DECISION_PENALTY_AMT":"11369.00","JUDGE_FIRST_NAME":"Richard","JUDGE_LAST_NAME":"Manning","sourceDate":"2021-12-30"},{"SOURCE_ROW_NUMBER":"423959","VIOLATION_NO":"8539981","DOCKET_NO":"WEST 2021-0067","DECISION_DT":"07/27/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"918.00","DECISION_PENALTY_AMT":"208.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2021-07-27"},{"SOURCE_ROW_NUMBER":"145891","VIOLATION_NO":"8539982","DOCKET_NO":"WEST 2021-0067","DECISION_DT":"07/27/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"5332.00","DECISION_PENALTY_AMT":"2692.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2021-07-27"},{"SOURCE_ROW_NUMBER":"418250","VIOLATION_NO":"9024341","DOCKET_NO":"WEST 2020-0073","DECISION_DT":"01/15/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"902.00","DECISION_PENALTY_AMT":"631.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2020-01-15"},{"SOURCE_ROW_NUMBER":"140978","VIOLATION_NO":"8487774","DOCKET_NO":"WEST 2020-0002","DECISION_DT":"12/23/2019","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1242.00","DECISION_PENALTY_AMT":"1242.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2019-12-23"},{"SOURCE_ROW_NUMBER":"141078","VIOLATION_NO":"9030416","DOCKET_NO":"WEST 2019-0520","DECISION_DT":"11/06/2019","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1146.00","DECISION_PENALTY_AMT":"891.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2019-11-06"},{"SOURCE_ROW_NUMBER":"135642","VIOLATION_NO":"9026369","DOCKET_NO":"WEST 2019-0028","DECISION_DT":"06/28/2019","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"69400.00","DECISION_PENALTY_AMT":"34700.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2019-06-28"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":7202,"firstDate":"2004-10-20","lastDate":"2022-04-12","metrics":{"recentRows":649,"cpdmSamples":3841,"voidSamples":3143,"validSamples":4059,"maxConcentration":48.044,"concentrationTotal":3543.747},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"414793","CASS_NUM":"51389995","SMP_TAKEN_DT":"4/12/2022","CONC":".061","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"CONTROL FILTER VOID","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2022-04-12"},{"SOURCE_ROW_NUMBER":"2992191","SMP_TAKEN_DT":"11/21/2021","CONC":".139","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HEADGATE OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2021-11-21"},{"SOURCE_ROW_NUMBER":"2736406","SMP_TAKEN_DT":"11/21/2021","CONC":".114","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"MULTIPLE SAMPLES SAME SHIFT","OCC_CD_DESC":"JACK SETTER (LONGWALL)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2021-11-21"},{"SOURCE_ROW_NUMBER":"2310021","SMP_TAKEN_DT":"11/21/2021","CONC":".114","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"JACK SETTER (LONGWALL)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2021-11-21"},{"SOURCE_ROW_NUMBER":"1968255","SMP_TAKEN_DT":"11/21/2021","CONC":".07","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CPDM","sourceDate":"2021-11-21"},{"SOURCE_ROW_NUMBER":"2395083","SMP_TAKEN_DT":"11/20/2021","CONC":".05","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HEADGATE OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2021-11-20"},{"SOURCE_ROW_NUMBER":"2309562","SMP_TAKEN_DT":"11/20/2021","CONC":".029","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CPDM","sourceDate":"2021-11-20"},{"SOURCE_ROW_NUMBER":"2139095","SMP_TAKEN_DT":"11/20/2021","CONC":".414","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"JACK SETTER (LONGWALL)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2021-11-20"},{"SOURCE_ROW_NUMBER":"2736787","SMP_TAKEN_DT":"11/19/2021","CONC":".068","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CPDM","sourceDate":"2021-11-19"},{"SOURCE_ROW_NUMBER":"2651676","SMP_TAKEN_DT":"11/19/2021","CONC":".029","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"HEADGATE OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2021-11-19"},{"SOURCE_ROW_NUMBER":"2566348","SMP_TAKEN_DT":"11/19/2021","CONC":".074","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CPDM","sourceDate":"2021-11-19"},{"SOURCE_ROW_NUMBER":"2225383","SMP_TAKEN_DT":"11/19/2021","CONC":".035","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"JACK SETTER (LONGWALL)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2021-11-19"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":75,"firstDate":"2005-08-25","lastDate":"2021-11-10","metrics":{"linkedIssuances":75},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":417,"firstDate":"2005-12-10","lastDate":"2021-07-10","metrics":{"decisions":416,"ssChanged":96,"recentRows":5,"decisionPenalty":903770.4,"proposedPenalty":1547861},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"159758","CITATION_NO":"8541428","CITATION_ISSUE_DT":"07/10/2021","DOCKET_NO":"WEST 2022-0003","DECISION_DT":"01/18/2022","CFR_STANDARD_CODE":"75.1725(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1385.00","DECISION_PENALTY_AMT":"1385.00","sourceDate":"2021-07-10"},{"SOURCE_ROW_NUMBER":"276949","CITATION_NO":"8540127","CITATION_ISSUE_DT":"06/10/2021","DOCKET_NO":"WEST 2021-0310","DECISION_DT":"12/30/2021","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"22770.00","DECISION_PENALTY_AMT":"11369.00","sourceDate":"2021-06-10"},{"SOURCE_ROW_NUMBER":"103893","CITATION_NO":"8540125","CITATION_ISSUE_DT":"06/09/2021","DOCKET_NO":"WEST 2021-0310","DECISION_DT":"12/30/2021","CFR_STANDARD_CODE":"75.380(d)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1006.00","DECISION_PENALTY_AMT":"1006.00","sourceDate":"2021-06-09"},{"SOURCE_ROW_NUMBER":"48079","CITATION_NO":"8540124","CITATION_ISSUE_DT":"06/09/2021","DOCKET_NO":"WEST 2021-0310","DECISION_DT":"12/30/2021","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"929.00","DECISION_PENALTY_AMT":"208.00","sourceDate":"2021-06-09"},{"SOURCE_ROW_NUMBER":"330575","CITATION_NO":"8540123","CITATION_ISSUE_DT":"06/08/2021","DOCKET_NO":"WEST 2021-0310","DECISION_DT":"12/30/2021","CFR_STANDARD_CODE":"77.1710(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"929.00","DECISION_PENALTY_AMT":"929.00","sourceDate":"2021-06-08"},{"SOURCE_ROW_NUMBER":"47311","CITATION_NO":"8540101","CITATION_ISSUE_DT":"11/16/2020","DOCKET_NO":"WEST 2022-0178","DECISION_DT":"05/23/2022","CFR_STANDARD_CODE":"75.1913(a)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"133.00","DECISION_PENALTY_AMT":".00","sourceDate":"2020-11-16"},{"SOURCE_ROW_NUMBER":"386690","CITATION_NO":"8539981","CITATION_ISSUE_DT":"09/02/2020","DOCKET_NO":"WEST 2021-0067","DECISION_DT":"07/27/2021","CFR_STANDARD_CODE":"75.1725(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"918.00","DECISION_PENALTY_AMT":"208.00","sourceDate":"2020-09-02"},{"SOURCE_ROW_NUMBER":"160026","CITATION_NO":"8539982","CITATION_ISSUE_DT":"09/02/2020","DOCKET_NO":"WEST 2021-0067","DECISION_DT":"07/27/2021","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"5332.00","DECISION_PENALTY_AMT":"2692.00","sourceDate":"2020-09-02"},{"SOURCE_ROW_NUMBER":"46944","CITATION_NO":"9024341","CITATION_ISSUE_DT":"08/25/2019","DOCKET_NO":"WEST 2020-0073","DECISION_DT":"01/15/2020","CFR_STANDARD_CODE":"77.404(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"902.00","DECISION_PENALTY_AMT":"631.00","sourceDate":"2019-08-25"},{"SOURCE_ROW_NUMBER":"328184","CITATION_NO":"8487774","CITATION_ISSUE_DT":"08/01/2019","DOCKET_NO":"WEST 2020-0002","DECISION_DT":"12/23/2019","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1242.00","DECISION_PENALTY_AMT":"1242.00","sourceDate":"2019-08-01"},{"SOURCE_ROW_NUMBER":"446614","CITATION_NO":"9030416","CITATION_ISSUE_DT":"06/18/2019","DOCKET_NO":"WEST 2019-0520","DECISION_DT":"11/06/2019","CFR_STANDARD_CODE":"77.1104","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1146.00","DECISION_PENALTY_AMT":"891.00","sourceDate":"2019-06-18"},{"SOURCE_ROW_NUMBER":"440134","CITATION_NO":"9026369","CITATION_ISSUE_DT":"04/10/2018","DOCKET_NO":"WEST 2019-0028","DECISION_DT":"06/28/2019","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"69400.00","DECISION_PENALTY_AMT":"34700.00","sourceDate":"2018-04-10"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":4718,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":21,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":882,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":20,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2004-07-15","lastDate":"2004-07-15","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":196,"firstDate":"2004-02-17","lastDate":"2022-05-18","metrics":{"inspectors":506,"recentRows":5,"onSiteHours":18165.75,"inspectionHours":34830.25,"inspectionSamples":1960},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"106977","EVENT_NO":"6466942","INSPECTION_BEGIN_DT":"05/18/2022","INSPECTION_END_DT":"08/22/2022","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.75","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2022-05-18"},{"SOURCE_ROW_NUMBER":"1153638","EVENT_NO":"6466923","INSPECTION_BEGIN_DT":"10/01/2021","INSPECTION_END_DT":"12/02/2021","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"117.25","SUM_TOTAL_ON_SITE_HOURS":"74","sourceDate":"2021-10-01"},{"SOURCE_ROW_NUMBER":"700201","EVENT_NO":"6466911","INSPECTION_BEGIN_DT":"07/07/2021","INSPECTION_END_DT":"09/22/2021","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"269","SUM_TOTAL_ON_SITE_HOURS":"162.25","sourceDate":"2021-07-07"},{"SOURCE_ROW_NUMBER":"381293","EVENT_NO":"6469451","INSPECTION_BEGIN_DT":"04/05/2021","INSPECTION_END_DT":"06/28/2021","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"361","SUM_TOTAL_ON_SITE_HOURS":"157","sourceDate":"2021-04-05"},{"SOURCE_ROW_NUMBER":"956075","EVENT_NO":"6462236","INSPECTION_BEGIN_DT":"01/04/2021","INSPECTION_END_DT":"03/25/2021","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"273.75","SUM_TOTAL_ON_SITE_HOURS":"130.5","sourceDate":"2021-01-04"},{"SOURCE_ROW_NUMBER":"311144","EVENT_NO":"6462725","INSPECTION_BEGIN_DT":"10/01/2020","INSPECTION_END_DT":"12/29/2020","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"396.75","SUM_TOTAL_ON_SITE_HOURS":"173.5","sourceDate":"2020-10-01"},{"SOURCE_ROW_NUMBER":"674449","EVENT_NO":"6462228","INSPECTION_BEGIN_DT":"07/01/2020","INSPECTION_END_DT":"09/23/2020","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"6","SUM_TOTAL_INSP_HOURS":"354","SUM_TOTAL_ON_SITE_HOURS":"159.5","sourceDate":"2020-07-01"},{"SOURCE_ROW_NUMBER":"1159897","EVENT_NO":"6462717","INSPECTION_BEGIN_DT":"04/13/2020","INSPECTION_END_DT":"04/14/2020","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"15","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2020-04-13"},{"SOURCE_ROW_NUMBER":"258697","EVENT_NO":"6462716","INSPECTION_BEGIN_DT":"04/07/2020","INSPECTION_END_DT":"06/25/2020","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"428.5","SUM_TOTAL_ON_SITE_HOURS":"217.5","sourceDate":"2020-04-07"},{"SOURCE_ROW_NUMBER":"361639","EVENT_NO":"6466798","INSPECTION_BEGIN_DT":"01/13/2020","INSPECTION_END_DT":"03/03/2020","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"235.5","SUM_TOTAL_ON_SITE_HOURS":"132.5","sourceDate":"2020-01-13"},{"SOURCE_ROW_NUMBER":"63664","EVENT_NO":"6466797","INSPECTION_BEGIN_DT":"01/02/2020","INSPECTION_END_DT":"01/13/2020","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"36","SUM_TOTAL_ON_SITE_HOURS":"18","sourceDate":"2020-01-02"},{"SOURCE_ROW_NUMBER":"794952","EVENT_NO":"6462701","INSPECTION_BEGIN_DT":"11/13/2019","INSPECTION_END_DT":"11/18/2019","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"24","SUM_TOTAL_ON_SITE_HOURS":"9.5","sourceDate":"2019-11-13"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":167,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2022-Q2":{"hours":965,"employees":3,"production":0},"2022-Q1":{"hours":1657,"employees":4,"production":0},"2021-Q4":{"hours":44582,"employees":117,"production":785427},"2021-Q3":{"hours":54489,"employees":110,"production":1010456},"2021-Q2":{"hours":70311,"employees":105,"production":590215},"2021-Q1":{"hours":74465,"employees":115,"production":808801},"2020-Q4":{"hours":71896,"employees":135,"production":494287},"2020-Q3":{"hours":85160,"employees":138,"production":582703},"2020-Q2":{"hours":78618,"employees":140,"production":656013},"2020-Q1":{"hours":79195,"employees":141,"production":691366},"2019-Q4":{"hours":73577,"employees":133,"production":190497},"2019-Q3":{"hours":83290,"employees":136,"production":816040}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":39,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2013":{"hours":661265,"employees":278,"production":4442616},"2014":{"hours":768420,"employees":315,"production":3369731},"2015":{"hours":697899,"employees":308,"production":3090175},"2016":{"hours":613137,"employees":279,"production":1167265},"2017":{"hours":499300,"employees":230,"production":1715801},"2018":{"hours":345251,"employees":169,"production":2210433},"2019":{"hours":303681,"employees":135,"production":2193565},"2020":{"hours":314869,"employees":139,"production":2424369},"2021":{"hours":243847,"employees":112,"production":3194899},"2022":{"hours":2622,"employees":4,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":505,"firstDate":"2004-12-15","lastDate":"2021-09-16","metrics":{"recentRows":26,"doseOver100":105,"actDoseTotal":37732,"pelDoseTotal":26608},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"276407","EVENT_NO":"6466911","SURVEY_DATE":"09/16/2021","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","ACT_DOSE_85":"9","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2021-09-16"},{"SOURCE_ROW_NUMBER":"276406","EVENT_NO":"6466911","SURVEY_DATE":"09/16/2021","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","ACT_DOSE_85":"8","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2021-09-16"},{"SOURCE_ROW_NUMBER":"276405","EVENT_NO":"6466911","SURVEY_DATE":"09/16/2021","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","ACT_DOSE_85":"7","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2021-09-16"},{"SOURCE_ROW_NUMBER":"276404","EVENT_NO":"6466911","SURVEY_DATE":"09/16/2021","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","ACT_DOSE_85":"5","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2021-09-16"},{"SOURCE_ROW_NUMBER":"276403","EVENT_NO":"6466911","SURVEY_DATE":"09/16/2021","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"40","ACT_DOSE_85":"15","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2021-09-16"},{"SOURCE_ROW_NUMBER":"276402","EVENT_NO":"6466911","SURVEY_DATE":"09/15/2021","OCCUPATION_CD_DESC":"ROCK DUSTER","MACHINE_CD":"40","ACT_DOSE_85":"6","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2021-09-15"},{"SOURCE_ROW_NUMBER":"276401","EVENT_NO":"6466911","SURVEY_DATE":"09/15/2021","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"40","ACT_DOSE_85":"112","PEL_DOSE_90":"47","SURVEY_TYPE":"I","sourceDate":"2021-09-15"},{"SOURCE_ROW_NUMBER":"276400","EVENT_NO":"6466911","SURVEY_DATE":"09/15/2021","OCCUPATION_CD_DESC":"FIRE BOSS PRE-SHIFT EXAMINER","MACHINE_CD":"40","ACT_DOSE_85":"9","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2021-09-15"},{"SOURCE_ROW_NUMBER":"276399","EVENT_NO":"6466911","SURVEY_DATE":"09/15/2021","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"40","ACT_DOSE_85":"68","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2021-09-15"},{"SOURCE_ROW_NUMBER":"276398","EVENT_NO":"6466911","SURVEY_DATE":"09/15/2021","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","ACT_DOSE_85":"2","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2021-09-15"},{"SOURCE_ROW_NUMBER":"276397","EVENT_NO":"6466911","SURVEY_DATE":"08/10/2021","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"08","ACT_DOSE_85":"47","PEL_DOSE_90":"31","SURVEY_TYPE":"I","sourceDate":"2021-08-10"},{"SOURCE_ROW_NUMBER":"276396","EVENT_NO":"6466911","SURVEY_DATE":"08/10/2021","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","ACT_DOSE_85":"8","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2021-08-10"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":284,"firstDate":"2005-02-23","lastDate":"2021-10-26","metrics":{"recentRows":25,"voidSamples":34,"maxQuartzPct":24,"validSamples":250,"quartzPctTotal":1489.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"18446","CASSETTE_NO":"58390703","SAMPLE_DT":"10/26/2021","QUARTZ_PCT":"01.3","QUARTZ_MICROGRAMS":"5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2021-10-26"},{"SOURCE_ROW_NUMBER":"166309","CASSETTE_NO":"58390783","SAMPLE_DT":"10/05/2021","QUARTZ_PCT":"01.8","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"HEADGATE OPERATOR","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2021-10-05"},{"SOURCE_ROW_NUMBER":"124840","CASSETTE_NO":"58390813","SAMPLE_DT":"10/05/2021","QUARTZ_PCT":"05.6","QUARTZ_MICROGRAMS":"48","OCC_CODE_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2021-10-05"},{"SOURCE_ROW_NUMBER":"111987","CASSETTE_NO":"58390725","SAMPLE_DT":"10/05/2021","QUARTZ_PCT":"02.6","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"MECHANIC","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2021-10-05"},{"SOURCE_ROW_NUMBER":"30929","CASSETTE_NO":"58390722","SAMPLE_DT":"10/05/2021","QUARTZ_PCT":"03.0","QUARTZ_MICROGRAMS":"36","OCC_CODE_DESC":"JACK SETTER (LONGWALL)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2021-10-05"},{"SOURCE_ROW_NUMBER":"151601","CASSETTE_NO":"58390762","SAMPLE_DT":"07/13/2021","QUARTZ_PCT":"02.2","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"HEADGATE OPERATOR","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2021-07-13"},{"SOURCE_ROW_NUMBER":"151455","CASSETTE_NO":"58390714","SAMPLE_DT":"07/13/2021","QUARTZ_PCT":"02.7","QUARTZ_MICROGRAMS":"9","OCC_CODE_DESC":"MECHANIC","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2021-07-13"},{"SOURCE_ROW_NUMBER":"122210","CASSETTE_NO":"58390713","SAMPLE_DT":"07/13/2021","QUARTZ_PCT":"02.7","QUARTZ_MICROGRAMS":"13","OCC_CODE_DESC":"JACK SETTER (LONGWALL)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2021-07-13"},{"SOURCE_ROW_NUMBER":"92686","CASSETTE_NO":"58390831","SAMPLE_DT":"07/13/2021","QUARTZ_PCT":"03.7","QUARTZ_MICROGRAMS":"21","OCC_CODE_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2021-07-13"},{"SOURCE_ROW_NUMBER":"11504","CASSETTE_NO":"58390706","SAMPLE_DT":"07/13/2021","QUARTZ_PCT":"00.6","QUARTZ_MICROGRAMS":"1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2021-07-13"},{"SOURCE_ROW_NUMBER":"149029","CASSETTE_NO":"58413756","SAMPLE_DT":"04/26/2021","QUARTZ_PCT":"02.1","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2021-04-26"},{"SOURCE_ROW_NUMBER":"79216","CASSETTE_NO":"58413945","SAMPLE_DT":"04/26/2021","QUARTZ_PCT":"01.8","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2021-04-26"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":2610,"firstDate":"2004-11-16","lastDate":"2022-06-03","metrics":{"ss":364,"amountDue":1720820.4,"contested":76,"amountPaid":1720666.4,"recentRows":54,"section104d":5,"unterminated":4,"proposedPenalty":2336979},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"3070217","VIOLATION_NO":"9150222","VIOLATION_ISSUE_DT":"06/03/2022","SIG_SUB":"N","PART_SECTION":"50.20-7(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/03/2022","PROPOSED_PENALTY":"133","AMOUNT_DUE":"133","AMOUNT_PAID":"133","CONTESTED_IND":"N","sourceDate":"2022-06-03"},{"SOURCE_ROW_NUMBER":"3071062","VIOLATION_NO":"9150249","VIOLATION_ISSUE_DT":"10/26/2021","SIG_SUB":"N","PART_SECTION":"75.321(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/26/2021","PROPOSED_PENALTY":"125","AMOUNT_DUE":"125","AMOUNT_PAID":"125","CONTESTED_IND":"N","sourceDate":"2021-10-26"},{"SOURCE_ROW_NUMBER":"3071061","VIOLATION_NO":"9150248","VIOLATION_ISSUE_DT":"10/20/2021","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/20/2021","PROPOSED_PENALTY":"146","AMOUNT_DUE":"146","AMOUNT_PAID":"146","CONTESTED_IND":"N","sourceDate":"2021-10-20"},{"SOURCE_ROW_NUMBER":"3071060","VIOLATION_NO":"9150247","VIOLATION_ISSUE_DT":"10/20/2021","SIG_SUB":"N","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/20/2021","PROPOSED_PENALTY":"146","AMOUNT_DUE":"146","AMOUNT_PAID":"146","CONTESTED_IND":"N","sourceDate":"2021-10-20"},{"SOURCE_ROW_NUMBER":"3071059","VIOLATION_NO":"9150246","VIOLATION_ISSUE_DT":"10/19/2021","SIG_SUB":"N","PART_SECTION":"75.1719-4(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/19/2021","PROPOSED_PENALTY":"187","AMOUNT_DUE":"187","AMOUNT_PAID":"187","CONTESTED_IND":"N","sourceDate":"2021-10-19"},{"SOURCE_ROW_NUMBER":"3071058","VIOLATION_NO":"9150245","VIOLATION_ISSUE_DT":"10/19/2021","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/19/2021","PROPOSED_PENALTY":"328","AMOUNT_DUE":"328","AMOUNT_PAID":"328","CONTESTED_IND":"N","sourceDate":"2021-10-19"},{"SOURCE_ROW_NUMBER":"3071057","VIOLATION_NO":"9150242","VIOLATION_ISSUE_DT":"10/04/2021","SIG_SUB":"N","PART_SECTION":"75.1106-3(a)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/04/2021","PROPOSED_PENALTY":"187","AMOUNT_DUE":"187","AMOUNT_PAID":"187","CONTESTED_IND":"N","sourceDate":"2021-10-04"},{"SOURCE_ROW_NUMBER":"3070616","VIOLATION_NO":"9150183","VIOLATION_ISSUE_DT":"08/09/2021","SIG_SUB":"N","PART_SECTION":"75.1722(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/09/2021","PROPOSED_PENALTY":"187","AMOUNT_DUE":"187","AMOUNT_PAID":"187","CONTESTED_IND":"N","sourceDate":"2021-08-09"},{"SOURCE_ROW_NUMBER":"3070615","VIOLATION_NO":"9150182","VIOLATION_ISSUE_DT":"08/08/2021","SIG_SUB":"N","PART_SECTION":"75.1909(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/09/2021","PROPOSED_PENALTY":"125","AMOUNT_DUE":"125","AMOUNT_PAID":"125","CONTESTED_IND":"N","sourceDate":"2021-08-08"},{"SOURCE_ROW_NUMBER":"3070614","VIOLATION_NO":"9030775","VIOLATION_ISSUE_DT":"08/03/2021","SIG_SUB":"N","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/12/2021","PROPOSED_PENALTY":"125","AMOUNT_DUE":"125","AMOUNT_PAID":"125","CONTESTED_IND":"N","sourceDate":"2021-08-03"},{"SOURCE_ROW_NUMBER":"3070613","VIOLATION_NO":"9030774","VIOLATION_ISSUE_DT":"07/27/2021","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/27/2021","PROPOSED_PENALTY":"279","AMOUNT_DUE":"279","AMOUNT_PAID":"279","CONTESTED_IND":"N","sourceDate":"2021-07-27"},{"SOURCE_ROW_NUMBER":"3070612","VIOLATION_NO":"8541432","VIOLATION_ISSUE_DT":"07/11/2021","SIG_SUB":"Y","PART_SECTION":"75.380(d)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/11/2021","PROPOSED_PENALTY":"416","AMOUNT_DUE":"416","AMOUNT_PAID":"416","CONTESTED_IND":"N","sourceDate":"2021-07-11"}]}],"safety":{"href":"/api/v1/mines/4801646/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4801646/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Criteria—MSHA Form 7000-1, Section D.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-I/part-50/subpart-C/section-50.20-7","part":"50","subchapter":"I","subpart":"C","id":"50.20-7","citation":"30 CFR 50.20-7","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER I—ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND PRODUCTION IN MINES","partHeading":"PART 50—NOTIFICATION, INVESTIGATION, REPORTS AND RECORDS OF ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND COAL PRODUCTION IN MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.321","heading":"Air quality.","id":"75.321","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.321","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The air in areas where persons work or travel, except as specified in paragraph (a)(2) of this section, shall contain at least 19.5 percent oxygen and not more than 0.5 percent carbon dioxide, and the volume and velocity of the air current in these areas shall be sufficient to dilute, render harmless, and carry away flammable, explosive, noxious, and harmful gases, dusts, smoke, and fumes.\n\n(2) The air in areas of bleeder entries and worked-out areas where persons work or travel shall contain at least 19.5 percent oxygen, and carbon dioxide levels shall not exceed 0.5 percent time weighted average and 3.0 percent short term exposure limit.\n\n(b) Notwithstanding the provisions of § 75.322, for the purpose of preventing explosions from gases other than methane, the following gases shall not be permitted to accumulate in excess of the concentrations listed below:\n\n(1) Carbon monoxide (CO)—2.5 percent\n\n(2) Hydrogen (H2)—.80 percent\n\n(3) Hydrogen sulfide (H2 S)—.80 percent\n\n(4) Acetylene (C2 H2)—.40 percent\n\n(5) Propane (C3 H8)—.40 percent\n\n(6) MAPP (methyl-acetylene-propylene-propodiene)—.30 percent","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1725","heading":"Machinery and equipment; operation and maintenance.","id":"75.1725","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1725","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","heading":"Mining machines, cap lamps; requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1719-4","part":"75","subchapter":"O","subpart":"R","id":"75.1719-4","citation":"30 CFR 75.1719-4","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1106-3","heading":"Storage of liquefied and nonliquefied compressed gas cylinders; requirements.","id":"75.1106-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1106-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Liquefied and nonliquefied compressed gas cylinders stored in an underground coal mine shall be:\n\n(1) Clearly marked and identified as to their contents in accordance with Department of Transportation regulations.\n\n(2) Placed securely in storage areas designated by the operator for such purpose, and where the height of the coalbed permits, in an upright position, preferably in specially designated racks, or otherwise secured against being accidently tipped over.\n\n(3) Protected against damage from falling material, contact with power lines and energized electrical equipment, heat from welding, cutting or soldering, and exposure to flammable liquids.\n\n(b) Liquefied and nonliquefied compressed gas cylinders shall not be stored or left unattended in any area inby the last open crosscut of an underground coal mine.\n\n(c) When not in use, the valves of all liquefied and nonliquefied compressed gas cylinders shall be in the closed position, and all hoses shall be removed from the cylinder.\n\n[36 FR 22061, Nov. 19, 1971]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1722","heading":"Mechanical equipment guards.","id":"75.1722","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1722","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1909","heading":"Nonpermissible diesel-powered equipment; design and performance requirements.","id":"75.1909","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-T/section-75.1909","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"T","subpartHeading":"Subpart T—Diesel-Powered Equipment","text":"(a) Nonpermissible diesel-powered equipment, except for the special category of equipment under § 75.1908(d), must be equipped with the following features:\n\n(1) An engine approved under subpart E of part 7 of this title equipped with an air filter sized in accordance with the engine manufacturer's recommendations, and an air filter service indicator set in accordance with the engine manufacturer's recommendations;\n\n(2) At least one portable multipurpose dry chemical type (ABC) fire extinguisher listed or approved by a nationally recognized independent testing laboratory with a 10A:60B:C or higher rating. The fire extinguisher must be located within easy reach of the equipment operator and protected from damage;\n\n(3) A fuel system specifically designed for diesel fuel meeting the following requirements:\n\n(i) A fuel tank and fuel lines that do not leak;\n\n(ii) A fuel tank that is substantially constructed and protected against damage by collision;\n\n(iii) A vent opening that maintains atmospheric pressure in the fuel tank, and that is designed to prevent fuel from splashing out of the vent opening;\n\n(iv) A self-closing filler cap on the fuel tank;\n\n(v) The fuel tank, filler and vent must be located so that leaks or spillage during refueling will not contact hot surfaces;\n\n(vi) Fuel line piping must be either steel-wire reinforced; synthetic elastomer-covered hose suitable for use with diesel fuel that has been tested and has been determined to be fire-resistant by the manufacturer; or metal;\n\n(vii) Fuel line piping must be clamped;\n\n(viii) Primary fuel lines must be located so that fuel line leaks do not contact hot surfaces;\n\n(ix) The fuel lines must be separated from electrical wiring and protected from damage in ordinary use;\n\n(x) A manual shutoff valve must be installed in the fuel system as close as practicable to the tank; and\n\n(xi) A water separator and fuel filter(s) must be provided.\n\n(4) A sensor to monitor the temperature and provide a visual warning of an overheated cylinder head on air-cooled engines;\n\n(5) Guarding to protect fuel, hydraulic, and electric lines when such lines pass near rotating parts or in the event of shaft failure;\n\n(6) Hydraulic tanks, fillers, vents, and lines located to prevent spillage or leaks from contacting hot surfaces;\n\n(7) Reflectors or warning lights mounted on the equipment which can be readily seen in all directions;\n\n(8) A means to direct exhaust gas away from the equipment operator, persons on board the machine, and combustible machine components;\n\n(9) A means to prevent unintentional free and uncontrolled descent of personnel-elevating work platforms; and\n\n(10) A means to prevent the spray from ruptured hydraulic or lubricating oil lines from being ignited by contact with engine exhaust system component surfaces.\n\n(b) Self-propelled nonpermissible diesel-powered equipment must have the following features in addition to those in paragraph (a):\n\n(1) A means to ensure that no stored hydraulic energy that will cause machine articulation is available after the engine is shut down;\n\n(2) A neutral start feature which ensures that engine cranking torque will not be transmitted through the powertrain and cause machine movement on vehicles utilizing fluid power transmissions;\n\n(3) For machines with steering wheels, brake pedals, and accelerator pedals, controls which are of automobile orientation;\n\n(4) An audible warning device conveniently located near the equipment operator;\n\n(5) Lights provided and maintained on both ends of the equipment. Equipment normally operated in both directions must be equipped with headlights for both directions;\n\n(6) Service brakes that act on each wheel of the vehicle and that are designed such that failure of any single component, except the brake actuation pedal or other similar actuation device, must not result in a complete loss of service braking capability;\n\n(7) Service brakes that safely bring the fully loaded vehicle to a complete stop on the maximum grade on which it is operated; and\n\n(8) No device that traps a column of fluid to hold the brake in the applied position shall be installed in any brake system, unless the trapped column of fluid is released when the equipment operator is no longer in contact with the brake activation device.\n\n(c) Self-propelled nonpermissible heavy-duty diesel-powered equipment under § 75.1908(a), except rail-mounted equipment, shall be provided with a supplemental braking system that:\n\n(1) Engages automatically within 5 seconds of the shutdown of the engine;\n\n(2) Safely brings the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(3) Holds the equipment stationary, despite any contraction of brake parts, exhaustion of any nonmechanical source of energy, or leakage;\n\n(4) Releases only by a manual control that does not operate any other equipment function;\n\n(5) Has a means in the equipment operator's compartment to apply the brakes manually without shutting down the engine, and a means to release and reengage the brakes without the engine operating; and\n\n(6) Has a means to ensure that the supplemental braking system is released before the equipment can be trammed, and is designed to ensure the brake is fully released at all times while the equipment is trammed.\n\n(d) Self-propelled nonpermissible light-duty diesel-powered equipment under § 75.1908(b), except rail-mounted equipment, must be provided with a parking brake that holds the fully loaded equipment stationary on the maximum grade on which it is operated despite any contraction of the brake parts, exhaustion of any nonmechanical source of energy, or leakage.\n\n(e) The supplemental and park brake systems required by paragraphs (c) and (d) must be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n(f) Self-propelled personnel-elevating work platforms must be provided with a means to ensure that the parking braking system is released before the equipment can be trammed, and must be designed to ensure the brake is fully released at all times while the equipment is trammed.\n\n(g) Any nonpermissible equipment that discharges its exhaust directly into a return air course must be provided with a power package approved under subpart F of part 7 of this title.\n\n(h) Self-propelled nonpermissible heavy-duty diesel-powered equipment meeting the requirements of § 75.1908(a) must be provided with an automatic fire suppression system meeting the requirements of § 75.1911.\n\n(i) Self-propelled nonpermissible light-duty diesel-powered equipment meeting the requirements of § 75.1908(b) must be provided with an automatic or manual fire suppression system meeting the requirements of § 75.1911.\n\n(j) Nonpermissible equipment that is not self-propelled must have the following features in addition to those listed in paragraph (a):\n\n(1) A means to prevent inadvertent movement of the equipment when parked;\n\n(2) Safety chains or other suitable secondary connections on equipment that is being towed; and\n\n(3) An automatic fire suppression system meeting the requirements of § 75.1911.\n\n[61 FR 55527, Oct. 25, 1996; 62 FR 34641, June 27, 1997]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.380","heading":"Escapeways; bituminous and lignite mines.","id":"75.380","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.380","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Except in situations addressed in § 75.381, § 75.385 and § 75.386, at least two separate and distinct travelable passageways shall be designated as escapeways and shall meet the requirements of this section.\n\n(b) (1) Escapeways shall be provided from each working section, and each area where mechanized mining equipment is being installed or removed, continuous to the surface escape drift opening or continuous to the escape shaft or slope facilities to the surface.\n\n(2) During equipment installation, these escapeways shall begin at the projected location for the section loading point. During equipment removal, they shall begin at the location of the last loading point.\n\n(c) The two separate and distinct escapeways required by this section shall not end at a common shaft, slope, or drift opening, except that multiple compartment shafts or slopes separated by walls constructed of noncombustible material may be used as separate and distinct passageways.\n\n(d) Each escapeway shall be—\n\n(1) Maintained in a safe condition to always assure passage of anyone, including disabled persons;\n\n(2) Clearly marked to show the route and direction of travel to the surface;\n\n(3) Maintained to at least a height of 5 feet from the mine floor to the mine roof, excluding the thickness of any roof support, except that the escapeways shall be maintained to at least the height of the coalbed, excluding the thickness of any roof support, where the coalbed is less than 5 feet. In areas of mines where escapeways pass through doors, the height may be less than 5 feet, provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. In areas of mines developed before November 16, 1992, where escapeways pass over or under overcasts or undercasts, the height may be less than 5 feet provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient height is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(4) Maintained at least 6 feet wide except—\n\n(i) Where necessary supplemental roof support is installed, the escapeway shall not be less than 4 feet wide; or\n\n(ii) Where the route of travel passes through doors or other permanent ventilation controls, the escapeway shall be at least 4 feet wide to enable miners to escape quickly in an emergency, or\n\n(iii) Where the alternate escapeway passes through doors or other permanent ventilation controls or where supplemental roof support is required and sufficient width is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher, or\n\n(iv) Where mobile equipment near working sections, and other equipment essential to the ongoing operation of longwall sections, is necessary during normal mining operations, such as material cars containing rock dust or roof control supplies, or is to be used for the evacuation of miners off the section in the event of an emergency. In any instance, escapeways shall be of sufficient width to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(5) Located to follow the most direct, safe and practical route to the nearest mine opening suitable for the safe evacuation of miners; and\n\n(6) Provided with ladders, stairways, ramps, or similar facilities where the escapeways cross over obstructions.\n\n(7) Provided with a continuous, durable directional lifeline or equivalent device that shall be—\n\n(i) Installed and maintained throughout the entire length of each escapeway as defined in paragraph (b)(1) of this section;\n\n(ii) Flame-resistant in accordance with the requirements of part 18 of this chapter upon replacement of existing lifelines; but in no case later than June 15, 2009;\n\n(iii) Marked with a reflective material every 25 feet;\n\n(iv) Located in such a manner for miners to use effectively to escape;\n\n(v) Equipped with one directional indicator cone securely attached to the lifeline, signifying the route of escape, placed at intervals not exceeding 100 feet. Cones shall be installed so that the tapered section points inby;\n\n(vi) Equipped with one sphere securely attached to the lifeline at each intersection where personnel doors are installed in adjacent crosscuts;\n\n(vii) Equipped with two securely attached cones, installed consecutively with the tapered section pointing inby, to signify an attached branch line is immediately ahead.\n\n(A) A branch line leading from the lifeline to an SCSR cache will be marked with four cones with the base sections in contact to form two diamond shapes. The cones must be placed within reach of the lifeline.\n\n(B) A branch line leading from the lifeline to a refuge alternative will be marked with a rigid spiraled coil at least eight inches in length. The spiraled coil must be placed within reach of the lifeline (see Illustration 1 below).\n\n(e) Surface openings shall be adequately protected to prevent surface fires, fumes, smoke, and flood water from entering the mine.\n\n(f) Primary escapeway. (1) One escapeway that is ventilated with intake air shall be designated as the primary escapeway. The primary escapeway shall have a higher ventilation pressure than the belt entry unless the mine operator submits an alternative in the mine ventilation plan to protect the integrity of the primary escapeway, based on mine specific conditions, which is approved by the district manager.\n\n(2) Paragraphs (f)(3) through (f)(7) of this section apply as follows:\n\n(i) To all areas of a primary escapeway developed on or after November 16, 1992;\n\n(ii) Effective as of June 10, 1997, to all areas of a primary escapeway developed between March 30, 1970 and November 16, 1992; and\n\n(iii) Effective as of June 10, 1997, to all areas of the primary escapeway developed prior to March 30, 1970 where separation of the belt and trolley haulage entries from the primary escapeway existed prior to November 16, 1992.\n\n(3) The following equipment is not permitted in the primary escapeway:\n\n(i) Mobile equipment hauling coal except for hauling coal incidental to cleanup or maintenance of the primary escapeway.\n\n(ii) Compressors, except—\n\n(A) Compressors necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Compressors that are components of equipment such as locomotives and rock dusting machines; and\n\n(C) Compressors of less than five horsepower.\n\n(iii) Underground transformer stations, battery charging stations, substations, and rectifiers except—\n\n(A) Where necessary to maintain the escapeway in safe, travelable condition; and\n\n(B) Battery charging stations and rectifiers and power centers with transformers that are either dry-type or contain nonflammable liquid, provided they are located on or near a working section and are moved as the section advances or retreats.\n\n(iv) Water pumps, except—\n\n(A) Water pumps necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Submersible pumps;\n\n(C) Permissible pumps and associated permissible switchgear;\n\n(D) Pumps located on or near a working section that are moved as the section advances or retreats;\n\n(E) Pumps installed in anthracite mines; and\n\n(F) Small portable pumps.\n\n(4) Mobile equipment operated in the primary escapeway, except for continuous miners and as provided in paragraphs (f)(5), (f)(6), and (f)(7) of this section, shall be equipped with a fire suppression system installed according to §§ 75.1107-3 through 75.1107-16 that is—\n\n(i) Manually operated and attended continuously by a person trained in the systems function and use, or\n\n(ii) A multipurpose dry chemical type capable of both automatic and manual activation.\n\n(5) Personnel carriers and small mobile equipment designed and used only for carrying people and small hand tools may be operated in primary escapeways if—\n\n(i) The equipment is provided with a multipurpose dry chemical type fire suppression system capable of both automatic and manual activation, and the suppression system is suitable for the intended application and is listed or approved by a nationally recognized independent testing laboratory, or,\n\n(ii) Battery powered and provided with two 10 pound multipurpose dry chemical portable fire extinguishers.\n\n(6) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment not provided with a fire suppression system may operate in the primary escapeway if no one is inby except those persons directly engaged in using or moving the equipment.\n\n(7) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment designated and used only as emergency vehicles or ambulances, may be operated in the primary escapeway without fire suppression systems.\n\n(g) Except where separation of belt and trolley haulage entries from designated escapeways did not exist before November 15, 1992, and except as provided in § 75.350(c), the primary escapeway must be separated from belt and trolley haulage entries for its entire length, to and including the first connecting crosscut outby each loading point except when a greater or lesser distance for this separation is specified and approved in the mine ventilation plan and does not pose a hazard to miners.\n\n(h) Alternate escapeway. One escapeway shall be designated as the alternate escapeway. The alternate escapeway shall be separated from the primary escapeway for its entire length, except that the alternate and primary escapeways may be ventilated from a common intake air shaft or slope opening.\n\n(i) Mechanical escape facilities shall be provided and maintained for—\n\n(1) Each shaft that is part of a designated escapeway and is greater than 50 feet in depth; and\n\n(2) Each slope from the coal seam to the surface that is part of a designated escapeway and is inclined more than 9 degrees from the horizontal.\n\n(j) Within 30 minutes after mine personnel on the surface have been notified of an emergency requiring evacuation, mechanical escape facilities provided under paragraph (i) of this section shall be operational at the bottom of shaft and slope openings that are part of escapeways.\n\n(k) Except where automatically activated hoisting equipment is used, the bottom of each shaft or slope opening that is part of a designated escapeway shall be equipped with a means of signaling a surface location where a person is always on duty when anyone is underground. When the signal is activated or the evacuation of persons underground is necessary, the person shall assure that mechanical escape facilities are operational as required by paragraph (j) of this section.\n\n(l)(1) Stairways or mechanical escape facilities shall be installed in shafts that are part of the designated escapeways and that are 50 feet or less in depth, except ladders may be used in shafts that are part of the designated escapeways and that are 5 feet or less in depth.\n\n(2) Stairways shall be constructed of concrete or metal, set on an angle not to exceed 45 degrees from the horizontal, and equipped on the open side with handrails. In addition, landing platforms that are at least 2 feet by 4 feet shall be installed at intervals not to exceed 20 vertical feet on the stairways and equipped on the open side with handrails.\n\n(3) Ladders shall be constructed of metal, anchored securely, and set on an angle not to exceed 60 degrees from the horizontal.\n\n(m) A travelway designed to prevent slippage shall be provided in slope and drift openings that are part of designated escapeways, unless mechanical escape facilities are installed.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 69 FR 17530, Apr. 2, 2004; 71 FR 12269, Mar. 9, 2006; 71 FR 71452, Dec. 8, 2006; 73 FR 80613, Dec. 31, 2008]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4801646","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}