{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"4800828","name":"Seminoe II Mine","status":"Abandoned","status_date":"2015-05-18","mine_type":"Facility","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WY","county":"Carbon","nearest_town":"Hanna","operator_id":"P17880","operator_name":"Arch Of Wyoming LLC","controller_id":"C15561","controller_name":"Arch Resources Inc","district":"C09","office":"Delta CO Field Office","employees":0,"latitude":41.949722,"longitude":-106.566389},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":1028},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4800828","name":"Seminoe II Mine"},"operator":{"type":"operator","id":"P17880","name":"Arch Of Wyoming LLC"},"controller":{"type":"controller","id":"C15561","name":"Arch Resources Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P17880","name":"Arch Of Wyoming LLC"},"object":{"type":"mine","id":"4800828","name":"Seminoe II Mine"},"validFrom":"1950-01-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4800828|P17880|1950-01-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00012","name":"Ashland Inc et al"},"object":{"type":"mine","id":"4800828","name":"Seminoe II Mine"},"validFrom":"1950-01-01","validTo":"2006-04-04","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4800828|C00012|1950-01-01|2006-04-04"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00012","name":"Ashland Inc et al"},"object":{"type":"operator","id":"P17880","name":"Arch Of Wyoming LLC"},"validFrom":"1950-01-01","validTo":"2006-04-04","current":false,"derived":true,"evidenceMineId":"4800828","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4800828|P17880|1950-01-01|C00012|1950-01-01|43208"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15561","name":"Arch Resources Inc"},"object":{"type":"mine","id":"4800828","name":"Seminoe II Mine"},"validFrom":"2006-04-05","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4800828|C15561|2006-04-05|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15561","name":"Arch Resources Inc"},"object":{"type":"operator","id":"P17880","name":"Arch Of Wyoming LLC"},"validFrom":"2006-04-05","validTo":null,"current":true,"derived":true,"evidenceMineId":"4800828","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4800828|P17880|1950-01-01|C15561|2006-04-05|96087"}}],"coverage":{"historyRecords":2,"edgeCount":5,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":3,"firstDate":"2001-08-06","lastDate":"2009-12-11","metrics":{"daysLost":134,"injuries":1,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"38634","DOCUMENT_NO":"220093550001","ACCIDENT_DT":"12/11/2009","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FIRE","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"The Crusher Motor Control Center and Building was extensively damaged by a fire sometime between the night of December 10 and 7:45 a.m. (time of discovery) on the morning of December 11, 2009.  The fire was essentially out at the time of discovery.  There were no mine personnel on the site at the time of the event.","sourceDate":"2009-12-11"},{"SOURCE_ROW_NUMBER":"47185","DOCUMENT_NO":"220020630046","ACCIDENT_DT":"02/25/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Welder (shop)","NO_INJURIES":"1","DAYS_LOST":"134","NARRATIVE":"EE HAD COMPLETED HIS SHIFT AND WALKED TOHIS PERSONAL VEHICLE IN THE PARKING LOT. WHILE ATTEMPTING TO ENTER HIS VEHICLE, EE SLIPPED ON ICE, FELL AND STRUCK LEFT KNEE ON GROUND.","sourceDate":"2002-02-25"},{"SOURCE_ROW_NUMBER":"51435","DOCUMENT_NO":"220012260013","ACCIDENT_DT":"08/06/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FIRE","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"SMOKE WAS OBSERVED AT THE CRUSHER FACILITY. UPON INVESTIGATION, IT WAS DETERMINED THAT A FIRE WAS BURNING ON THE BELT BETWEEN THE PRIMARY AND SECONDARY CRUSHERS. DUE TO THE CONFINED AREA OF TH E FIRE AND THE PROXIMITY OF A PROFESSIONAL FIRE COMPANY, THE HANNA FIRE DEPARTMENT WAS CALLED TO FIGHT THE BLAZE.","sourceDate":"2001-08-06"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2015-05-18","lastDate":"2015-05-18","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":105,"firstDate":"2000-03-22","lastDate":"2014-10-29","metrics":{"ss":25,"delinquent":100,"recentRows":0,"paidPenalty":16941,"proposedPenalty":17568,"currentAssessment":16941},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1527851","VIOLATION_NO":"8479053","ISSUE_DT":"10/29/2014","CFR_STANDARD_CD":"77.701","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-10-29"},{"SOURCE_ROW_NUMBER":"1527850","VIOLATION_NO":"8479052","ISSUE_DT":"10/22/2014","CFR_STANDARD_CD":"48.29(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-10-22"},{"SOURCE_ROW_NUMBER":"1527849","VIOLATION_NO":"8479051","ISSUE_DT":"10/22/2014","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-10-22"},{"SOURCE_ROW_NUMBER":"1527848","VIOLATION_NO":"8479050","ISSUE_DT":"10/21/2014","CFR_STANDARD_CD":"47.41(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-10-21"},{"SOURCE_ROW_NUMBER":"1527847","VIOLATION_NO":"8479049","ISSUE_DT":"10/16/2014","CFR_STANDARD_CD":"77.1713(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-10-16"},{"SOURCE_ROW_NUMBER":"1526694","VIOLATION_NO":"8478555","ISSUE_DT":"11/05/2013","CFR_STANDARD_CD":"77.1607(n)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-11-05"},{"SOURCE_ROW_NUMBER":"1526338","VIOLATION_NO":"8477952","ISSUE_DT":"07/24/2013","CFR_STANDARD_CD":"77.502-2","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-07-24"},{"SOURCE_ROW_NUMBER":"1526123","VIOLATION_NO":"8478061","ISSUE_DT":"01/08/2013","CFR_STANDARD_CD":"77.412(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-01-08"},{"SOURCE_ROW_NUMBER":"1506172","VIOLATION_NO":"8477533","ISSUE_DT":"01/18/2012","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-01-18"},{"SOURCE_ROW_NUMBER":"1506171","VIOLATION_NO":"8477530","ISSUE_DT":"01/09/2012","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-01-09"},{"SOURCE_ROW_NUMBER":"1506170","VIOLATION_NO":"8477503","ISSUE_DT":"11/22/2011","CFR_STANDARD_CD":"77.205(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"190.00","CURRENT_ASSESSMENT_AMT":"190.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-11-22"},{"SOURCE_ROW_NUMBER":"1506471","VIOLATION_NO":"8469124","ISSUE_DT":"08/02/2011","CFR_STANDARD_CD":"77.400(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"224.00","CURRENT_ASSESSMENT_AMT":"224.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-08-02"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":8,"firstDate":"2004-07-10","lastDate":"2011-07-12","metrics":{"appeals":0,"decisions":8,"recentRows":0,"decisionPenalty":1325,"originalPenalty":2444},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"325403","VIOLATION_NO":"8468151","DOCKET_NO":"WEST 2010-1840","DECISION_DT":"07/12/2011","DECISION_TYPE_CODE_DESC":"Withdrawal","ORIGINAL_PENALTY_AMT":"117.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2011-07-12"},{"SOURCE_ROW_NUMBER":"31699","VIOLATION_NO":"7621696","DOCKET_NO":"WEST 2008-1088","DECISION_DT":"11/18/2009","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Gary","JUDGE_LAST_NAME":"Melick","sourceDate":"2009-11-18"},{"SOURCE_ROW_NUMBER":"31698","VIOLATION_NO":"7621692","DOCKET_NO":"WEST 2008-1088","DECISION_DT":"11/18/2009","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Gary","JUDGE_LAST_NAME":"Melick","sourceDate":"2009-11-18"},{"SOURCE_ROW_NUMBER":"245150","VIOLATION_NO":"7619781","DOCKET_NO":"WEST 2004-416","DECISION_DT":"05/25/2005","DECISION_TYPE_CODE_DESC":"Withdrawal","ORIGINAL_PENALTY_AMT":"375.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2005-05-25"},{"SOURCE_ROW_NUMBER":"3387","VIOLATION_NO":"7619782","DOCKET_NO":"WEST 2004-416","DECISION_DT":"05/25/2005","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"525.00","DECISION_PENALTY_AMT":"175.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2005-05-25"},{"SOURCE_ROW_NUMBER":"244228","VIOLATION_NO":"7619776","DOCKET_NO":"WEST 2004-280","DECISION_DT":"09/27/2004","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"525.00","DECISION_PENALTY_AMT":"525.00","JUDGE_FIRST_NAME":"Richard","JUDGE_LAST_NAME":"Manning","sourceDate":"2004-09-27"},{"SOURCE_ROW_NUMBER":"1909","VIOLATION_NO":"7619775","DOCKET_NO":"WEST 2004-240","DECISION_DT":"08/05/2004","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"177.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Richard","JUDGE_LAST_NAME":"Manning","sourceDate":"2004-08-05"},{"SOURCE_ROW_NUMBER":"3168","VIOLATION_NO":"7619778","DOCKET_NO":"WEST2004-416-1","DECISION_DT":"07/10/2004","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"525.00","DECISION_PENALTY_AMT":"525.00","JUDGE_FIRST_NAME":"Arthur","JUDGE_LAST_NAME":"Amchan","sourceDate":"2004-07-10"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":116,"firstDate":"2000-03-22","lastDate":"2012-06-26","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":6,"validSamples":110,"maxConcentration":14.355,"concentrationTotal":75.646},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"511371","CASS_NUM":"57947645","SMP_TAKEN_DT":"6/26/2012","CONC":".476","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-06-26"},{"SOURCE_ROW_NUMBER":"396329","CASS_NUM":"57946236","SMP_TAKEN_DT":"6/26/2012","CONC":".136","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-06-26"},{"SOURCE_ROW_NUMBER":"47265","CASS_NUM":"57946238","SMP_TAKEN_DT":"6/26/2012","CONC":".501","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-06-26"},{"SOURCE_ROW_NUMBER":"1543577","CASS_NUM":"57946083","SMP_TAKEN_DT":"11/17/2011","CONC":".292","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-11-17"},{"SOURCE_ROW_NUMBER":"945818","CASS_NUM":"57946085","SMP_TAKEN_DT":"11/17/2011","CONC":".166","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-11-17"},{"SOURCE_ROW_NUMBER":"772309","CASS_NUM":"57946084","SMP_TAKEN_DT":"11/17/2011","CONC":".046","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ELECTRICIAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-11-17"},{"SOURCE_ROW_NUMBER":"718143","CASS_NUM":"57946092","SMP_TAKEN_DT":"11/17/2011","CONC":".182","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OILER/GREASER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-11-17"},{"SOURCE_ROW_NUMBER":"1255921","CASS_NUM":"57868598","SMP_TAKEN_DT":"8/22/2011","CONC":".886","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"WATER TRUCK OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-08-22"},{"SOURCE_ROW_NUMBER":"889690","CASS_NUM":"57868581","SMP_TAKEN_DT":"8/22/2011","CONC":".279","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-08-22"},{"SOURCE_ROW_NUMBER":"1494031","CASS_NUM":"57894306","SMP_TAKEN_DT":"3/22/2011","CONC":".083","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-03-22"},{"SOURCE_ROW_NUMBER":"889119","CASS_NUM":"57894307","SMP_TAKEN_DT":"3/22/2011","CONC":".031","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ELECTRICIAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-03-22"},{"SOURCE_ROW_NUMBER":"406313","CASS_NUM":"57894301","SMP_TAKEN_DT":"3/22/2011","CONC":".173","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-03-22"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":1,"firstDate":"2008-07-21","lastDate":"2008-07-21","metrics":{"linkedIssuances":1},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":5,"firstDate":"2003-12-03","lastDate":"2010-08-02","metrics":{"decisions":5,"ssChanged":2,"recentRows":0,"decisionPenalty":275,"proposedPenalty":1217},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"358590","CITATION_NO":"8468151","CITATION_ISSUE_DT":"08/02/2010","DOCKET_NO":"WEST 2010-1840","DECISION_DT":"07/12/2011","CFR_STANDARD_CODE":"62.130(a)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"117.00","DECISION_PENALTY_AMT":".00","sourceDate":"2010-08-02"},{"SOURCE_ROW_NUMBER":"288773","CITATION_NO":"7621696","CITATION_ISSUE_DT":"02/13/2008","DOCKET_NO":"WEST 2008-1088","DECISION_DT":"11/18/2009","CFR_STANDARD_CODE":"77.404(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":".00","sourceDate":"2008-02-13"},{"SOURCE_ROW_NUMBER":"62797","CITATION_NO":"7621692","CITATION_ISSUE_DT":"02/12/2008","DOCKET_NO":"WEST 2008-1088","DECISION_DT":"11/18/2009","CFR_STANDARD_CODE":"77.404(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2008-02-12"},{"SOURCE_ROW_NUMBER":"170137","CITATION_NO":"7619782","CITATION_ISSUE_DT":"12/03/2003","DOCKET_NO":"WEST 2004-416","DECISION_DT":"05/25/2005","CFR_STANDARD_CODE":"77.902","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"525.00","DECISION_PENALTY_AMT":"175.00","sourceDate":"2003-12-03"},{"SOURCE_ROW_NUMBER":"113737","CITATION_NO":"7619781","CITATION_ISSUE_DT":"12/03/2003","DOCKET_NO":"WEST 2004-416","DECISION_DT":"05/25/2005","CFR_STANDARD_CODE":"77.902","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"375.00","DECISION_PENALTY_AMT":".00","sourceDate":"2003-12-03"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":416,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":66,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"1950-01-01","lastDate":"1950-01-01","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":62,"firstDate":"2000-03-07","lastDate":"2014-11-13","metrics":{"inspectors":68,"recentRows":0,"onSiteHours":923.25,"inspectionHours":1867.5,"inspectionSamples":58},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"259413","EVENT_NO":"4483793","INSPECTION_BEGIN_DT":"11/13/2014","INSPECTION_END_DT":"11/13/2014","ACTIVITY_CODE":"E15","ACTIVITY":"Compliance Follow-up Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2014-11-13"},{"SOURCE_ROW_NUMBER":"75321","EVENT_NO":"4483790","INSPECTION_BEGIN_DT":"10/09/2014","INSPECTION_END_DT":"11/04/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"56.25","SUM_TOTAL_ON_SITE_HOURS":"30.5","sourceDate":"2014-10-09"},{"SOURCE_ROW_NUMBER":"1027505","EVENT_NO":"6460151","INSPECTION_BEGIN_DT":"09/17/2014","INSPECTION_END_DT":"09/22/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"23.5","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2014-09-17"},{"SOURCE_ROW_NUMBER":"1129145","EVENT_NO":"4483657","INSPECTION_BEGIN_DT":"10/30/2013","INSPECTION_END_DT":"11/18/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"61.5","SUM_TOTAL_ON_SITE_HOURS":"31.25","sourceDate":"2013-10-30"},{"SOURCE_ROW_NUMBER":"606846","EVENT_NO":"4483596","INSPECTION_BEGIN_DT":"07/10/2013","INSPECTION_END_DT":"08/13/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"59.75","SUM_TOTAL_ON_SITE_HOURS":"33.5","sourceDate":"2013-07-10"},{"SOURCE_ROW_NUMBER":"625928","EVENT_NO":"4483560","INSPECTION_BEGIN_DT":"01/02/2013","INSPECTION_END_DT":"01/10/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"40.75","SUM_TOTAL_ON_SITE_HOURS":"21.75","sourceDate":"2013-01-02"},{"SOURCE_ROW_NUMBER":"77349","EVENT_NO":"4474996","INSPECTION_BEGIN_DT":"06/18/2012","INSPECTION_END_DT":"06/26/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"61","SUM_TOTAL_ON_SITE_HOURS":"36.25","sourceDate":"2012-06-18"},{"SOURCE_ROW_NUMBER":"772967","EVENT_NO":"4474938","INSPECTION_BEGIN_DT":"11/14/2011","INSPECTION_END_DT":"01/23/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"73.25","SUM_TOTAL_ON_SITE_HOURS":"37.5","sourceDate":"2011-11-14"},{"SOURCE_ROW_NUMBER":"229193","EVENT_NO":"4474982","INSPECTION_BEGIN_DT":"08/01/2011","INSPECTION_END_DT":"08/22/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"56.75","SUM_TOTAL_ON_SITE_HOURS":"37.25","sourceDate":"2011-08-01"},{"SOURCE_ROW_NUMBER":"877348","EVENT_NO":"4474927","INSPECTION_BEGIN_DT":"03/21/2011","INSPECTION_END_DT":"03/28/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"50","SUM_TOTAL_ON_SITE_HOURS":"33","sourceDate":"2011-03-21"},{"SOURCE_ROW_NUMBER":"503761","EVENT_NO":"4474828","INSPECTION_BEGIN_DT":"07/28/2010","INSPECTION_END_DT":"08/10/2010","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"76.5","SUM_TOTAL_ON_SITE_HOURS":"42","sourceDate":"2010-07-28"},{"SOURCE_ROW_NUMBER":"148361","EVENT_NO":"4474718","INSPECTION_BEGIN_DT":"03/22/2010","INSPECTION_END_DT":"03/29/2010","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"66.5","SUM_TOTAL_ON_SITE_HOURS":"34.5","sourceDate":"2010-03-22"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":21,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002-Q4":{"hours":10166,"employees":21,"production":66631},"2002-Q3":{"hours":10235,"employees":20,"production":94477},"2002-Q2":{"hours":12166,"employees":22,"production":88864},"2002-Q1":{"hours":11165,"employees":20,"production":8733},"2001-Q4":{"hours":13134,"employees":26,"production":100915},"2001-Q3":{"hours":13700,"employees":26,"production":49936},"2001-Q2":{"hours":12626,"employees":24,"production":101620},"2001-Q1":{"hours":6953,"employees":12,"production":46516},"2000-Q4":{"hours":9914,"employees":19,"production":96023},"2000-Q3":{"hours":9135,"employees":20,"production":152162},"2000-Q2":{"hours":10323,"employees":21,"production":85321},"2000-Q1":{"hours":7698,"employees":14,"production":69277}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":25,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2006":{"hours":31728,"employees":16,"production":0},"2007":{"hours":28078,"employees":14,"production":0},"2008":{"hours":30468,"employees":14,"production":0},"2009":{"hours":28415,"employees":15,"production":0},"2010":{"hours":23411,"employees":11,"production":0},"2011":{"hours":23123,"employees":11,"production":0},"2012":{"hours":23664,"employees":12,"production":0},"2013":{"hours":16606,"employees":8,"production":0},"2014":{"hours":16114,"employees":8,"production":0},"2015":{"hours":7181,"employees":9,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":73,"firstDate":"2001-07-17","lastDate":"2013-11-13","metrics":{"recentRows":0,"doseOver100":3,"actDoseTotal":3043,"pelDoseTotal":1709},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"273427","EVENT_NO":"4483657","SURVEY_DATE":"11/13/2013","OCCUPATION_CD_DESC":"WELDER (SHOP)","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"7","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2013-11-13"},{"SOURCE_ROW_NUMBER":"273426","EVENT_NO":"4483560","SURVEY_DATE":"01/08/2013","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"20","MANUFACTURER_CD":"120","ACT_DOSE_85":"8","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2013-01-08"},{"SOURCE_ROW_NUMBER":"273425","EVENT_NO":"4483560","SURVEY_DATE":"01/08/2013","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"20","MANUFACTURER_CD":"120","ACT_DOSE_85":"3","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2013-01-08"},{"SOURCE_ROW_NUMBER":"273417","EVENT_NO":"4474996","SURVEY_DATE":"06/26/2012","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"25","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2012-06-26"},{"SOURCE_ROW_NUMBER":"273416","EVENT_NO":"4474996","SURVEY_DATE":"06/26/2012","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"46","PEL_DOSE_90":"20","SURVEY_TYPE":"I","sourceDate":"2012-06-26"},{"SOURCE_ROW_NUMBER":"273415","EVENT_NO":"4474996","SURVEY_DATE":"06/26/2012","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"60","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2012-06-26"},{"SOURCE_ROW_NUMBER":"273411","EVENT_NO":"4474938","SURVEY_DATE":"01/10/2012","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"20","MANUFACTURER_CD":"119","ACT_DOSE_85":"11","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2012-01-10"},{"SOURCE_ROW_NUMBER":"273410","EVENT_NO":"4474938","SURVEY_DATE":"01/10/2012","OCCUPATION_CD_DESC":"WELDER (SHOP)","MACHINE_CD":"20","MANUFACTURER_CD":"119","ACT_DOSE_85":"7","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2012-01-10"},{"SOURCE_ROW_NUMBER":"273409","EVENT_NO":"4474938","SURVEY_DATE":"01/10/2012","OCCUPATION_CD_DESC":"OILER/GREASER","MACHINE_CD":"20","MANUFACTURER_CD":"119","ACT_DOSE_85":"46","PEL_DOSE_90":"29","SURVEY_TYPE":"I","sourceDate":"2012-01-10"},{"SOURCE_ROW_NUMBER":"273408","EVENT_NO":"4474938","SURVEY_DATE":"01/10/2012","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"36","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2012-01-10"},{"SOURCE_ROW_NUMBER":"273414","EVENT_NO":"4474982","SURVEY_DATE":"08/03/2011","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"36","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2011-08-03"},{"SOURCE_ROW_NUMBER":"273413","EVENT_NO":"4474982","SURVEY_DATE":"08/03/2011","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"9","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2011-08-03"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":17,"firstDate":"2000-06-22","lastDate":"2011-09-01","metrics":{"recentRows":0,"voidSamples":2,"maxQuartzPct":11.2,"validSamples":15,"quartzPctTotal":82.7},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"96508","CASSETTE_NO":"57868898","SAMPLE_DT":"09/01/2011","QUARTZ_PCT":"07.8","OCC_CODE_DESC":"WATER TRUCK OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"INVALID OR MISSING DATE","sourceDate":"2011-09-01"},{"SOURCE_ROW_NUMBER":"146611","CASSETTE_NO":"57523076","SAMPLE_DT":"12/03/2003","QUARTZ_PCT":"00.3","OCC_CODE_DESC":"MECHANIC","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-12-03"},{"SOURCE_ROW_NUMBER":"132678","CASSETTE_NO":"57523509","SAMPLE_DT":"04/15/2003","QUARTZ_PCT":"02.3","OCC_CODE_DESC":"MECHANIC","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-04-15"},{"SOURCE_ROW_NUMBER":"147676","CASSETTE_NO":"57523495","SAMPLE_DT":"03/12/2003","OCC_CODE_DESC":"COAL TRUCK DRIVER","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"QUARTZ LABORATORY VOID","sourceDate":"2003-03-12"},{"SOURCE_ROW_NUMBER":"32730","CASSETTE_NO":"57523494","SAMPLE_DT":"03/12/2003","QUARTZ_PCT":"04.3","OCC_CODE_DESC":"COAL TRUCK DRIVER","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-03-12"},{"SOURCE_ROW_NUMBER":"130243","CASSETTE_NO":"57426369","SAMPLE_DT":"05/06/2002","QUARTZ_PCT":"08.5","OCC_CODE_DESC":"COAL TRUCK DRIVER","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-05-06"},{"SOURCE_ROW_NUMBER":"130176","CASSETTE_NO":"57426379","SAMPLE_DT":"05/06/2002","QUARTZ_PCT":"08.1","OCC_CODE_DESC":"COAL TRUCK DRIVER","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-05-06"},{"SOURCE_ROW_NUMBER":"131932","CASSETTE_NO":"50574597","SAMPLE_DT":"11/13/2001","QUARTZ_PCT":"11.2","OCC_CODE_DESC":"COAL TRUCK DRIVER","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-11-13"},{"SOURCE_ROW_NUMBER":"141545","CASSETTE_NO":"57338832","SAMPLE_DT":"10/23/2001","QUARTZ_PCT":"10.8","OCC_CODE_DESC":"COAL TRUCK DRIVER","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-10-23"},{"SOURCE_ROW_NUMBER":"47302","CASSETTE_NO":"57338828","SAMPLE_DT":"10/16/2001","QUARTZ_PCT":"01.7","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-10-16"},{"SOURCE_ROW_NUMBER":"103506","CASSETTE_NO":"57326826","SAMPLE_DT":"03/07/2001","QUARTZ_PCT":"07.6","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-03-07"},{"SOURCE_ROW_NUMBER":"11777","CASSETTE_NO":"57326825","SAMPLE_DT":"03/07/2001","QUARTZ_PCT":"03.7","OCC_CODE_DESC":"COAL TRUCK DRIVER","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-03-07"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":106,"firstDate":"2000-03-22","lastDate":"2014-10-29","metrics":{"ss":25,"amountDue":16941,"contested":6,"amountPaid":16941,"recentRows":0,"section104d":1,"unterminated":0,"proposedPenalty":17568},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"3052307","VIOLATION_NO":"8479053","VIOLATION_ISSUE_DT":"10/29/2014","SIG_SUB":"N","PART_SECTION":"77.701","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/13/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-10-29"},{"SOURCE_ROW_NUMBER":"3052306","VIOLATION_NO":"8479052","VIOLATION_ISSUE_DT":"10/22/2014","SIG_SUB":"N","PART_SECTION":"48.29(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/22/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-10-22"},{"SOURCE_ROW_NUMBER":"3052305","VIOLATION_NO":"8479051","VIOLATION_ISSUE_DT":"10/22/2014","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/29/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-10-22"},{"SOURCE_ROW_NUMBER":"3052304","VIOLATION_NO":"8479050","VIOLATION_ISSUE_DT":"10/21/2014","SIG_SUB":"N","PART_SECTION":"47.41(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/21/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-10-21"},{"SOURCE_ROW_NUMBER":"3052303","VIOLATION_NO":"8479049","VIOLATION_ISSUE_DT":"10/16/2014","SIG_SUB":"N","PART_SECTION":"77.1713(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/16/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-10-16"},{"SOURCE_ROW_NUMBER":"3052322","VIOLATION_NO":"8478555","VIOLATION_ISSUE_DT":"11/05/2013","SIG_SUB":"N","PART_SECTION":"77.1607(n)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/05/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-11-05"},{"SOURCE_ROW_NUMBER":"3052279","VIOLATION_NO":"8477952","VIOLATION_ISSUE_DT":"07/24/2013","SIG_SUB":"N","PART_SECTION":"77.502-2","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/24/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-07-24"},{"SOURCE_ROW_NUMBER":"3052223","VIOLATION_NO":"8478061","VIOLATION_ISSUE_DT":"01/08/2013","SIG_SUB":"N","PART_SECTION":"77.412(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/08/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-01-08"},{"SOURCE_ROW_NUMBER":"3052325","VIOLATION_NO":"8477533","VIOLATION_ISSUE_DT":"01/18/2012","SIG_SUB":"N","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/18/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-01-18"},{"SOURCE_ROW_NUMBER":"3052324","VIOLATION_NO":"8477530","VIOLATION_ISSUE_DT":"01/09/2012","SIG_SUB":"N","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/20/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-01-09"},{"SOURCE_ROW_NUMBER":"3052323","VIOLATION_NO":"8477503","VIOLATION_ISSUE_DT":"11/22/2011","SIG_SUB":"Y","PART_SECTION":"77.205(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/22/2011","PROPOSED_PENALTY":"190","AMOUNT_DUE":"190","AMOUNT_PAID":"190","CONTESTED_IND":"N","sourceDate":"2011-11-22"},{"SOURCE_ROW_NUMBER":"3052282","VIOLATION_NO":"8469124","VIOLATION_ISSUE_DT":"08/02/2011","SIG_SUB":"Y","PART_SECTION":"77.400(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/02/2011","PROPOSED_PENALTY":"224","AMOUNT_DUE":"224","AMOUNT_PAID":"224","CONTESTED_IND":"N","sourceDate":"2011-08-02"}]}],"safety":{"href":"/api/v1/mines/4800828/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4800828/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Grounding metallic frames, casings, and other enclosures of electric equipment.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-H/section-77.701","part":"77","subchapter":"O","subpart":"H","id":"77.701","citation":"30 CFR 77.701","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 48.29","heading":"Records of training.","id":"48.29","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-48/subpart-B/section-48.29","part":"48","partHeading":"PART 48—TRAINING AND RETRAINING OF MINERS","subchapter":"H","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","subpart":"B","subpartHeading":"Subpart B—Training and Retraining of Miners Working at Surface Mines and Surface Areas of Underground Mines","text":"(a) Upon a miner's completion of each MSHA approved training program, the operator shall record and certify on MSHA form 5000-23 that the miner has received the specified training. A copy of the training certificate shall be given to the miner at the completion of the training. The training certificates for each miner shall be available at the mine site for inspection by MSHA and for examination by the miners, the miners' representative and State inspection agencies. When a miner leaves the operator's employ, the miner shall be entitled to a copy of his training certificates.\n\n(b) False certification that training was given shall be punishable under section 110 (a) and (f) of the Act.\n\n(c) Copies of training certificates for currently employed miners shall be kept at the mine site for 2 years, or for 60 days after termination of employment.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[43 FR 47459, Oct. 13, 1978, as amended at 47 FR 14706, Apr. 6, 1982; 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1110","heading":"Examination and maintenance of firefighting equipment.","id":"77.1110","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1110","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment shall be continuously maintained in a usable and operative condition. Fire extinguishers shall be examined at least once every 6 months and the date of such examination shall be recorded on a permanent tag attached to the extinguisher.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 47.41","heading":"Requirement for container labels.","id":"47.41","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-47/subpart-E/section-47.41","part":"47","partHeading":"PART 47—HAZARD COMMUNICATION (HazCom)","subchapter":"H","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","subpart":"E","subpartHeading":"Subpart E—Container Labels and Other Forms of Warning","text":"(a) The operator must ensure that each container of a hazardous chemical has a label. If a container is tagged or marked with the appropriate information, it is labeled.\n\n(1) The operator must replace a container label immediately if it is missing or if the hazard information on the label is unreadable.\n\n(2) The operator must not remove or deface existing labels on containers of hazardous chemicals.\n\n(b) For each hazardous chemical produced at the mine, the operator must prepare a container label and update this label with any significant, new information about the chemical's hazards within 3 months of becoming aware of this information.\n\n(c) For each hazardous chemical brought to the mine, the operator must replace an outdated label when a revised label is received from the chemical's manufacturer or supplier. The operator is not responsible for an inaccurate label obtained from the chemical's manufacturer or supplier.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1713","heading":"Daily inspection of surface coal mine; certified person; reports of inspection.","id":"77.1713","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-R/section-77.1713","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) At least once during each working shift, or more often if necessary for safety, each active working area and each active surface installation shall be examined by a certified person designated by the operator to conduct such examinations for hazardous conditions and any hazardous conditions noted during such examinations shall be reported to the operator and shall be corrected by the operator.\n\n(b) If any hazardous condition noted during an examination conducted in accordance with paragraph (a) of this section creates an imminent danger, the person conducting such examination shall notify the operator and the operator shall withdraw all persons from the area affected, except those persons referred to in section 104(d) of the Act, until the danger is abated.\n\n(c) After each examination conducted in accordance with the provisions of paragraph (a) of this section, each certified person who conducted all or any part of the examination required shall enter with ink or indelible pencil in a book approved by the Secretary the date and a report of the condition of the mine or any area of the mine which he has inspected together with a report of the nature and location of any hazardous condition found to be present at the mine. The book in which such entries are made shall be kept in an area at the mine designated by the operator to minimize the danger of destruction by fire or other hazard.\n\n(d) All examination reports recorded in accordance with the provisions of paragraph (c) of this section shall include a report of the action taken to abate hazardous conditions and shall be signed or countersigned each day by at least one of the following persons:\n\n(1) The surface mine foreman;\n\n(2) The assistant superintendent of the mine;\n\n(3) The superintendent of the mine;\n\n(4) The person designated by the operator as responsible for health and safety at the mine; or,\n\n(5) An equivalent mine official.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995; 63 FR 58613, Oct. 30, 1998]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1607","heading":"Loading and haulage equipment; operation.","id":"77.1607","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1607","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Vehicles shall follow at a safe distance; passing shall be limited to areas of adequate clearance and visibility.\n\n(b) Mobile equipment operators shall have full control of the equipment while it is in motion.\n\n(c) Equipment operating speeds shall be prudent and consistent with conditions of roadway, grades, clearance, visibility, traffic, and the type of equipment used.\n\n(d) Cabs of mobile equipment shall be kept free of extraneous materials.\n\n(e) Operators shall sit facing the direction of travel while operating equipment with dual controls.\n\n(f) When an equipment operator is present, men shall notify him before getting on or off equipment.\n\n(g) Equipment operators shall be certain, by signal or other means, that all persons are clear before starting or moving equipment.\n\n(h) Where possible, aerial tramways shall not be started until the tramway operator has ascertained that everyone is in the clear.\n\n(i) Dust control measures shall be taken where dust significantly reduces visibility of equipment operators.\n\n(j) Dippers, buckets, loading booms, or heavy suspended loads shall not be swung over the cabs of haulage vehicles until the drivers are out of the cabs and in safe locations, unless the trucks are designed specifically to protect the drivers from falling material.\n\n(k) Men shall not work or pass under the buckets or booms of loaders in operation.\n\n(l) Tires shall be deflated before repairs on them are started and adequate means shall be provided to prevent wheel locking rims from creating a hazard during tire inflation.\n\n(m) Electrically powered mobile equipment shall not be left unattended unless the master switch is in the off position, all operating controls are in the neutral position, and the brakes are set or other equivalent precautions are taken against rolling.\n\n(n) Mobile equipment shall not be left unattended unless the brakes are set. The wheels shall be turned into a bank or berm, or shall be blocked, when such equipment is parked on a grade.\n\n(o) Lights, flares, or other warning devices shall be posted when parked equipment creates a hazard to vehicular traffic.\n\n(p) Dippers, buckets, scraper blades, and similar movable parts shall be secured or lowered to the ground when not in use.\n\n(q) Shovel trailing cables shall not be moved with the shovel dipper unless cable slings or sleds are used.\n\n(r) Equipment which is to be hauled shall be loaded and protected so as to prevent sliding or spillage.\n\n(s) When moving between work areas, the equipment shall be secured in the travel position.\n\n(t) Any load extending more than 4 feet beyond the rear of the vehicle body should be marked clearly with a red flag by day and a red light at night.\n\n(u) Tow bars shall be used to tow heavy equipment and a safety chain shall be used in conjunction with each tow bar.\n\n(v) Railroad cars shall be kept under control at all times by the car dropper. Cars shall be dropped at a safe rate and in a manner that will insure that the car dropper maintains a safe position while working and traveling around the cars.\n\n(w) Railroad cars shall not be coupled or uncoupled manually from the inside of curves unless the railroad and cars are so designed to eliminate any hazard from coupling or uncoupling cars from inside of curves.\n\n(x) Persons shall wear safety belts when dropping railroad cars.\n\n(y) Railcars shall not be left on sidetracks unless ample clearance is provided for traffic on adjacent tracks.\n\n(z) Parked railcars, unless held effectively by brakes, shall be blocked securely.\n\n(aa) Railroad cars and all trucks shall be trimmed properly when they have been loaded higher than the confines of their cargo space.\n\n(bb) When the entire length of a conveyor is visible from the starting switch, the operator shall visually check to make certain that all persons are in the clear before starting the conveyor. When the entire length of the conveyor is not visible from the starting switch, a positive audible or visible warning system shall be installed and operated to warn persons that the conveyor will be started.\n\n(cc) Unguarded conveyors with walkways shall be equipped with emergency stop devices or cords along their full length.\n\n(dd) Adequate backstops or brakes shall be installed on inclined-conveyor drive units to prevent conveyors from running in reverse if a hazard to personnel would be caused.\n\n(ee) Aerial tram conveyor buckets shall not be overloaded, and feed shall be regulated to prevent spillage.","occurrenceCount":1},{"chapter":"I","heading":"Electric equipment; frequency of examination and testing.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502-2","part":"77","subchapter":"O","subpart":"F","id":"77.502-2","citation":"30 CFR 77.502-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Compressed air systems.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.412","part":"77","subchapter":"O","subpart":"E","id":"77.412","citation":"30 CFR 77.412","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.205","heading":"Travelways at surface installations.","id":"77.205","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.205","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Safe means of access shall be provided and maintained to all working places.\n\n(b) Travelways and platforms or other means of access to areas where persons are required to travel or work, shall be kept clear of all extraneous material and other stumbling or slipping hazards.\n\n(c) Inclined travelways shall be constructed of nonskid material or equipped with cleats.\n\n(d) Regularly used travelways shall be sanded, salted, or cleared of snow and ice as soon as practicable.\n\n(e) Crossovers, elevated walkways, elevated ramps, and stairways shall be of substantial construction, provided with handrails, and maintained in good condition. Where necessary toeboards shall be provided.\n\n(f) Crossovers shall be provided where it is necessary to cross conveyors.\n\n(g) Moving conveyors shall be crossed only at designated crossover points.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.400","heading":"Mechanical equipment guards.","id":"77.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.400","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings; shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Overhead belts shall be guarded if the whipping action from a broken line would be hazardous to persons below.\n\n(c) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(d) Except when testing the machinery, guards shall be securely in place while machinery is being operated.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4800828","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}