{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4609667","name":"Willibet Surface Mine","status":"NonProducing","status_date":"2025-05-19","mine_type":"Surface","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Raleigh","nearest_town":"Coal City","operator_id":"0118488","operator_name":"Pocahontas Coal Company LLC,","controller_id":"0085453","controller_name":"Metinvest B V","district":"C04","office":"Beckley Field Office","employees":0,"latitude":37.628056,"longitude":-81.199167},"coverage":{"contributingSources":11,"registeredSources":20,"sourceRows":41},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609667","name":"Willibet Surface Mine"},"operator":{"type":"operator","id":"0118488","name":"Pocahontas Coal Company LLC,"},"controller":{"type":"controller","id":"0085453","name":"Metinvest B V"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"0085453","name":"Metinvest B V"},"object":{"type":"mine","id":"4609667","name":"Willibet Surface Mine"},"validFrom":"2011-06-10","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609667|0085453|2011-06-10|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0118488","name":"Pocahontas Coal Company LLC,"},"object":{"type":"mine","id":"4609667","name":"Willibet Surface Mine"},"validFrom":"2024-01-28","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609667|0118488|2024-01-28|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0085453","name":"Metinvest B V"},"object":{"type":"operator","id":"0118488","name":"Pocahontas Coal Company LLC,"},"validFrom":"2024-01-28","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609667","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609667|0118488|2024-01-28|0085453|2011-06-10|13634"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2025-05-19","lastDate":"2025-05-19","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":4,"firstDate":"2024-12-12","lastDate":"2025-06-05","metrics":{"ss":0,"delinquent":4,"recentRows":4,"paidPenalty":679,"proposedPenalty":679,"currentAssessment":679},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2931762","VIOLATION_NO":"5024531","ISSUE_DT":"06/05/2025","CFR_STANDARD_CD":"77.205(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2025-06-05"},{"SOURCE_ROW_NUMBER":"2931761","VIOLATION_NO":"5024530","ISSUE_DT":"06/05/2025","CFR_STANDARD_CD":"77.205(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2025-06-05"},{"SOURCE_ROW_NUMBER":"2931704","VIOLATION_NO":"9599407","ISSUE_DT":"12/12/2024","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"226.00","CURRENT_ASSESSMENT_AMT":"226.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2024-12-12"},{"SOURCE_ROW_NUMBER":"2931703","VIOLATION_NO":"9599406","ISSUE_DT":"12/12/2024","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2024-12-12"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":11,"firstDate":"2024-12-12","lastDate":"2025-06-09","metrics":{"recentRows":11,"cpdmSamples":0,"voidSamples":0,"validSamples":11,"maxConcentration":0.536,"concentrationTotal":1.921},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1641181","CASS_NUM":"58544098","SMP_TAKEN_DT":"6/9/2025","CONC":".028","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-06-09"},{"SOURCE_ROW_NUMBER":"417389","CASS_NUM":"58544087","SMP_TAKEN_DT":"6/9/2025","CONC":".067","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-06-09"},{"SOURCE_ROW_NUMBER":"220672","CASS_NUM":"58544114","SMP_TAKEN_DT":"6/9/2025","CONC":".536","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-06-09"},{"SOURCE_ROW_NUMBER":"903804","CASS_NUM":"51607525","SMP_TAKEN_DT":"5/8/2025","CONC":".146","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-05-08"},{"SOURCE_ROW_NUMBER":"377882","CASS_NUM":"51607990","SMP_TAKEN_DT":"5/8/2025","CONC":".094","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-05-08"},{"SOURCE_ROW_NUMBER":"1271110","CASS_NUM":"51607957","SMP_TAKEN_DT":"2/20/2025","CONC":".241","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-02-20"},{"SOURCE_ROW_NUMBER":"1144220","CASS_NUM":"51607554","SMP_TAKEN_DT":"2/20/2025","CONC":".071","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-02-20"},{"SOURCE_ROW_NUMBER":"978957","CASS_NUM":"58537947","SMP_TAKEN_DT":"1/30/2025","CONC":".46","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-01-30"},{"SOURCE_ROW_NUMBER":"947241","CASS_NUM":"58537941","SMP_TAKEN_DT":"1/30/2025","CONC":".054","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-01-30"},{"SOURCE_ROW_NUMBER":"1119985","CASS_NUM":"51607627","SMP_TAKEN_DT":"12/12/2024","CONC":".033","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2024-12-12"},{"SOURCE_ROW_NUMBER":"125018","CASS_NUM":"51607544","SMP_TAKEN_DT":"12/12/2024","CONC":".191","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2024-12-12"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"2024-01-28","lastDate":"2024-01-28","metrics":{"recentRows":1,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":5,"firstDate":"2024-10-21","lastDate":"2026-04-01","metrics":{"inspectors":6,"recentRows":5,"onSiteHours":80.25,"inspectionHours":129.25,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"789102","EVENT_NO":"F0170D9","INSPECTION_BEGIN_DT":"04/01/2026","INSPECTION_END_DT":"04/01/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2026-04-01"},{"SOURCE_ROW_NUMBER":"185611","EVENT_NO":"F0170CF","INSPECTION_BEGIN_DT":"02/05/2026","INSPECTION_END_DT":"02/05/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.75","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2026-02-05"},{"SOURCE_ROW_NUMBER":"943860","EVENT_NO":"F00A080","INSPECTION_BEGIN_DT":"09/02/2025","INSPECTION_END_DT":"09/22/2025","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2025-09-02"},{"SOURCE_ROW_NUMBER":"407209","EVENT_NO":"F00A075","INSPECTION_BEGIN_DT":"05/28/2025","INSPECTION_END_DT":"06/12/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"33.25","SUM_TOTAL_ON_SITE_HOURS":"22","sourceDate":"2025-05-28"},{"SOURCE_ROW_NUMBER":"821845","EVENT_NO":"F00A062","INSPECTION_BEGIN_DT":"10/21/2024","INSPECTION_END_DT":"01/30/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"86.25","SUM_TOTAL_ON_SITE_HOURS":"55.75","sourceDate":"2024-10-21"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":7,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2026-Q2":{"hours":2464,"employees":2,"production":0},"2026-Q1":{"hours":1608,"employees":3,"production":0},"2025-Q4":{"hours":0,"employees":0,"production":0},"2025-Q3":{"hours":0,"employees":0,"production":0},"2025-Q2":{"hours":6452,"employees":10,"production":225},"2025-Q1":{"hours":11342,"employees":19,"production":18076},"2024-Q4":{"hours":2410,"employees":19,"production":14206}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":3,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2024":{"hours":2410,"employees":19,"production":14206},"2025":{"hours":17794,"employees":15,"production":18301},"2026":{"hours":4072,"employees":3,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":2,"firstDate":"2025-01-30","lastDate":"2025-01-30","metrics":{"recentRows":2,"doseOver100":0,"actDoseTotal":69,"pelDoseTotal":12},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"272254","EVENT_NO":"F00A062","SURVEY_DATE":"01/30/2025","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"49","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2025-01-30"},{"SOURCE_ROW_NUMBER":"272253","EVENT_NO":"F00A062","SURVEY_DATE":"01/30/2025","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"20","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2025-01-30"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":2,"firstDate":"2025-01-30","lastDate":"2025-06-09","metrics":{"recentRows":2,"voidSamples":0,"maxQuartzPct":2.1,"validSamples":2,"quartzPctTotal":2.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"166591","CASSETTE_NO":"58544114","SAMPLE_DT":"06/09/2025","QUARTZ_PCT":"00.4","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-06-09"},{"SOURCE_ROW_NUMBER":"161299","CASSETTE_NO":"58537947","SAMPLE_DT":"01/30/2025","QUARTZ_PCT":"02.1","QUARTZ_MICROGRAMS":"9","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-01-30"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":4,"firstDate":"2024-12-12","lastDate":"2025-06-05","metrics":{"ss":0,"amountDue":679,"contested":0,"amountPaid":679,"recentRows":4,"section104d":0,"unterminated":0,"proposedPenalty":679},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2998176","VIOLATION_NO":"5024531","VIOLATION_ISSUE_DT":"06/05/2025","SIG_SUB":"N","PART_SECTION":"77.205(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/09/2025","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2025-06-05"},{"SOURCE_ROW_NUMBER":"2998175","VIOLATION_NO":"5024530","VIOLATION_ISSUE_DT":"06/05/2025","SIG_SUB":"N","PART_SECTION":"77.205(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/09/2025","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2025-06-05"},{"SOURCE_ROW_NUMBER":"2998178","VIOLATION_NO":"9599407","VIOLATION_ISSUE_DT":"12/12/2024","SIG_SUB":"N","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/30/2024","PROPOSED_PENALTY":"226","AMOUNT_DUE":"226","AMOUNT_PAID":"226","CONTESTED_IND":"N","sourceDate":"2024-12-12"},{"SOURCE_ROW_NUMBER":"2998177","VIOLATION_NO":"9599406","VIOLATION_ISSUE_DT":"12/12/2024","SIG_SUB":"N","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"12/17/2024","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2024-12-12"}]}],"safety":{"href":"/api/v1/mines/4609667/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609667/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":{"averageEmployees":19,"companyType":"Independent Producer Operator","components":[{"averageEmployees":19,"laborHours":2410,"mineType":"Surface","productionTons":14206}],"county":"Raleigh","laborHours":2410,"mineName":"Willibet Surface Mine","mineType":"Surface","mshaId":"4609667","operatingAddress":"109 Appalachian Drive, Beckley, WV 25801","operatingCompany":"Pocahontas Coal Company Llc,","operationType":"Mine only","productionTons":14206,"reportedRows":1,"sourceUrl":"https://www.eia.gov/coal/data/public/xls/coalpublic2024.xlsx","state":"West Virginia (Southern)","status":"Active, men working, not producing","supplyRegion":"Appalachia Central","union":"","year":2024},"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.205","heading":"Travelways at surface installations.","id":"77.205","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.205","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Safe means of access shall be provided and maintained to all working places.\n\n(b) Travelways and platforms or other means of access to areas where persons are required to travel or work, shall be kept clear of all extraneous material and other stumbling or slipping hazards.\n\n(c) Inclined travelways shall be constructed of nonskid material or equipped with cleats.\n\n(d) Regularly used travelways shall be sanded, salted, or cleared of snow and ice as soon as practicable.\n\n(e) Crossovers, elevated walkways, elevated ramps, and stairways shall be of substantial construction, provided with handrails, and maintained in good condition. Where necessary toeboards shall be provided.\n\n(f) Crossovers shall be provided where it is necessary to cross conveyors.\n\n(g) Moving conveyors shall be crossed only at designated crossover points.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":2}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609667","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}