{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4609649","name":"JIREH","status":"Active","status_date":"2024-02-01","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Logan","nearest_town":"Omar","operator_id":"P02779","operator_name":"JET COAL COMPANY, INC.","controller_id":"C00996","controller_name":"Anthony  Newsome","district":"C04","office":"Logan WV Field Office","employees":56,"latitude":37.759444,"longitude":-82.011944},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":2702},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609649","name":"JIREH"},"operator":{"type":"operator","id":"P02779","name":"JET COAL COMPANY, INC."},"controller":{"type":"controller","id":"C00996","name":"Anthony  Newsome"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00996","name":"Anthony  Newsome"},"object":{"type":"mine","id":"4609649","name":"JIREH"},"validFrom":"1975-04-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609649|C00996|1975-04-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0150681","name":"John T  Quintrell"},"object":{"type":"mine","id":"4609649","name":"JIREH"},"validFrom":"2021-11-16","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609649|0150681|2021-11-16|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0179673","name":"Pocahontas Processing, LLC"},"object":{"type":"mine","id":"4609649","name":"JIREH"},"validFrom":"2023-04-05","validTo":"2023-11-08","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609649|0179673|2023-04-05|2023-11-08"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0150681","name":"John T  Quintrell"},"object":{"type":"operator","id":"0179673","name":"Pocahontas Processing, LLC"},"validFrom":"2023-04-05","validTo":"2023-11-08","current":false,"derived":true,"evidenceMineId":"4609649","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609649|0179673|2023-04-05|0150681|2021-11-16|31090"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P02779","name":"JET COAL COMPANY, INC."},"object":{"type":"mine","id":"4609649","name":"JIREH"},"validFrom":"2023-11-09","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609649|P02779|2023-11-09|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00996","name":"Anthony  Newsome"},"object":{"type":"operator","id":"P02779","name":"JET COAL COMPANY, INC."},"validFrom":"2023-11-09","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609649","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609649|P02779|2023-11-09|C00996|1975-04-01|51567"}}],"coverage":{"historyRecords":2,"edgeCount":6,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":5,"firstDate":"2025-03-31","lastDate":"2026-07-24","metrics":{"daysLost":500,"injuries":5,"fatalities":0,"recentRows":5,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"25711","DOCUMENT_NO":"220262110019","ACCIDENT_DT":"07/24/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by powered moving object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"44","NARRATIVE":"While in #2 entry waiting on miner, EE set down behind #18 stinger (4 wheeler).  Section boss backed stinger up, and bumped EE with corner of stinger to back. EE was able to finish shift. On Monday 7/27/26  EE went to get x-rayed, they have EE off work till EE follows up with doctor the following week.","sourceDate":"2026-07-24"},{"SOURCE_ROW_NUMBER":"16936","DOCUMENT_NO":"220262110017","ACCIDENT_DT":"06/29/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"82","NARRATIVE":"While leaving mining office, going down office steps EE missed 3rd step from bottom. Lost footing and twisted EE's knee. EE did not fall down was able to catch self. The accident happened 15 minutes prior to shift, EE did work the entire shift after.","sourceDate":"2026-06-29"},{"SOURCE_ROW_NUMBER":"59878","DOCUMENT_NO":"220260890101","ACCIDENT_DT":"03/24/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Struck by rolling or sliding object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","NARRATIVE":"Just after loading shuttle car, miner operator was struck by rib, causing them to fall injuring their left foot. Had x ray done at hospital, showing no fracture, but going to x ray again after swelling goes down to make sure.","sourceDate":"2026-03-24"},{"SOURCE_ROW_NUMBER":"8402","DOCUMENT_NO":"220260890102","ACCIDENT_DT":"03/24/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Struck by rolling or sliding object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","NARRATIVE":"While mining in #3 entry of section. Shuttle car operator was struck by rib burst to left side after being loaded by miner returning to feeder.  Causing several small scratches and cuts to arms and side of face. Employee is going to follow up with a x ray in a few days to make sure no fractures.","sourceDate":"2026-03-24"},{"SOURCE_ROW_NUMBER":"55631","DOCUMENT_NO":"220250970018","ACCIDENT_DT":"03/31/2025","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"374","NARRATIVE":"While roof bolting in #3 left of 0001 MMU, a rib rolled off striking operator, side bolter operator on top side of left forearm and lower left leg. The rib was approximately 1 foot by 6 foot long.  The result of the accident was a fractured lower left leg and several stitches to the top of left forearm.","sourceDate":"2025-03-31"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2024-02-01","lastDate":"2024-02-01","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":233,"firstDate":"2023-06-07","lastDate":"2026-08-13","metrics":{"ss":61,"delinquent":219,"recentRows":233,"paidPenalty":60961,"proposedPenalty":72632,"currentAssessment":71517},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"3001015","VIOLATION_NO":"5133727","ISSUE_DT":"08/13/2026","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-13"},{"SOURCE_ROW_NUMBER":"3001014","VIOLATION_NO":"5133726","ISSUE_DT":"08/13/2026","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-13"},{"SOURCE_ROW_NUMBER":"3001013","VIOLATION_NO":"5133725","ISSUE_DT":"08/13/2026","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-13"},{"SOURCE_ROW_NUMBER":"3001012","VIOLATION_NO":"5133724","ISSUE_DT":"08/13/2026","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-13"},{"SOURCE_ROW_NUMBER":"3001011","VIOLATION_NO":"5133723","ISSUE_DT":"08/13/2026","CFR_STANDARD_CD":"77.410(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-13"},{"SOURCE_ROW_NUMBER":"3001010","VIOLATION_NO":"5133722","ISSUE_DT":"08/13/2026","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-13"},{"SOURCE_ROW_NUMBER":"2941602","VIOLATION_NO":"5099733","ISSUE_DT":"08/12/2026","CFR_STANDARD_CD":"75.807","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-12"},{"SOURCE_ROW_NUMBER":"2941601","VIOLATION_NO":"5099732","ISSUE_DT":"08/12/2026","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"165.00","CURRENT_ASSESSMENT_AMT":"165.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-12"},{"SOURCE_ROW_NUMBER":"3001009","VIOLATION_NO":"5133710","ISSUE_DT":"08/04/2026","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-04"},{"SOURCE_ROW_NUMBER":"3001008","VIOLATION_NO":"5131821","ISSUE_DT":"08/04/2026","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"658.00","CURRENT_ASSESSMENT_AMT":"658.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-04"},{"SOURCE_ROW_NUMBER":"3001007","VIOLATION_NO":"5131820","ISSUE_DT":"08/04/2026","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-08-04"},{"SOURCE_ROW_NUMBER":"2941605","VIOLATION_NO":"5133714","ISSUE_DT":"08/04/2026","CFR_STANDARD_CD":"48.31(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1550.00","CURRENT_ASSESSMENT_AMT":"1550.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-04"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":7,"firstDate":"2024-06-26","lastDate":"2026-02-20","metrics":{"appeals":0,"decisions":7,"recentRows":7,"decisionPenalty":2026,"originalPenalty":3141},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"462336","VIOLATION_NO":"5091980","DOCKET_NO":"WEVA 2026-0094","DECISION_DT":"02/20/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1590.00","DECISION_PENALTY_AMT":"700.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-02-20"},{"SOURCE_ROW_NUMBER":"455203","VIOLATION_NO":"9834737","DOCKET_NO":"WEVA 2025-0174","DECISION_DT":"02/18/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"221.00","DECISION_PENALTY_AMT":"147.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2025-02-18"},{"SOURCE_ROW_NUMBER":"163975","VIOLATION_NO":"9834738","DOCKET_NO":"WEVA 2025-0174","DECISION_DT":"02/18/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"221.00","DECISION_PENALTY_AMT":"147.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2025-02-18"},{"SOURCE_ROW_NUMBER":"453865","VIOLATION_NO":"9833613","DOCKET_NO":"WEVA 2025-0038","DECISION_DT":"02/04/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"305.00","DECISION_PENALTY_AMT":"228.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2025-02-04"},{"SOURCE_ROW_NUMBER":"444547","VIOLATION_NO":"9596333","DOCKET_NO":"WEVA 2024-0078","DECISION_DT":"07/12/2024","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"518.00","DECISION_PENALTY_AMT":"518.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2024-07-12"},{"SOURCE_ROW_NUMBER":"444289","VIOLATION_NO":"9596334","DOCKET_NO":"WEVA 2024-0078","DECISION_DT":"07/12/2024","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"143.00","DECISION_PENALTY_AMT":"143.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2024-07-12"},{"SOURCE_ROW_NUMBER":"446416","VIOLATION_NO":"9590695","DOCKET_NO":"WEVA 2024-0151","DECISION_DT":"06/26/2024","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"143.00","DECISION_PENALTY_AMT":"143.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2024-06-26"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":1605,"firstDate":"2023-06-14","lastDate":"2026-10-07","metrics":{"recentRows":1605,"cpdmSamples":1455,"voidSamples":511,"validSamples":1094,"maxConcentration":2.774,"concentrationTotal":603.557},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2177524","SMP_TAKEN_DT":"10/7/2026","CONC":".297","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"1921868","SMP_TAKEN_DT":"10/7/2026","CONC":".116","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2517099","SMP_TAKEN_DT":"10/6/2026","CONC":".495","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2176152","SMP_TAKEN_DT":"10/6/2026","CONC":".285","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2005564","SMP_TAKEN_DT":"10/6/2026","CONC":".665","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"1750486","SMP_TAKEN_DT":"10/6/2026","CONC":".271","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2858757","SMP_TAKEN_DT":"10/5/2026","CONC":".12","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"2177335","SMP_TAKEN_DT":"10/5/2026","CONC":".153","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"2176408","SMP_TAKEN_DT":"10/5/2026","CONC":".785","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"1751747","SMP_TAKEN_DT":"10/5/2026","CONC":".279","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"2517092","SMP_TAKEN_DT":"9/11/2026","CONC":".619","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-09-11"},{"SOURCE_ROW_NUMBER":"2006695","SMP_TAKEN_DT":"9/11/2026","CONC":".236","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-09-11"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":2,"firstDate":"2023-07-12","lastDate":"2025-12-01","metrics":{"linkedIssuances":2},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":7,"firstDate":"2023-09-05","lastDate":"2025-09-02","metrics":{"decisions":7,"ssChanged":0,"recentRows":7,"decisionPenalty":2026,"proposedPenalty":3141},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"224183","CITATION_NO":"5091980","CITATION_ISSUE_DT":"09/02/2025","DOCKET_NO":"WEVA 2026-0094","DECISION_DT":"02/20/2026","CFR_STANDARD_CODE":"48.31(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1590.00","DECISION_PENALTY_AMT":"700.00","sourceDate":"2025-09-02"},{"SOURCE_ROW_NUMBER":"451637","CITATION_NO":"9834738","CITATION_ISSUE_DT":"11/25/2024","DOCKET_NO":"WEVA 2025-0174","DECISION_DT":"02/18/2025","CFR_STANDARD_CODE":"77.1605(d)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"221.00","DECISION_PENALTY_AMT":"147.00","sourceDate":"2024-11-25"},{"SOURCE_ROW_NUMBER":"281404","CITATION_NO":"9834737","CITATION_ISSUE_DT":"11/25/2024","DOCKET_NO":"WEVA 2025-0174","DECISION_DT":"02/18/2025","CFR_STANDARD_CODE":"77.1605(d)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"221.00","DECISION_PENALTY_AMT":"147.00","sourceDate":"2024-11-25"},{"SOURCE_ROW_NUMBER":"448136","CITATION_NO":"9833613","CITATION_ISSUE_DT":"08/21/2024","DOCKET_NO":"WEVA 2025-0038","DECISION_DT":"02/04/2025","CFR_STANDARD_CODE":"77.1606(c)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"305.00","DECISION_PENALTY_AMT":"228.00","sourceDate":"2024-08-21"},{"SOURCE_ROW_NUMBER":"110161","CITATION_NO":"9590695","CITATION_ISSUE_DT":"11/07/2023","DOCKET_NO":"WEVA 2024-0151","DECISION_DT":"06/26/2024","CFR_STANDARD_CODE":"45.4","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"143.00","DECISION_PENALTY_AMT":"143.00","sourceDate":"2023-11-07"},{"SOURCE_ROW_NUMBER":"219213","CITATION_NO":"9596333","CITATION_ISSUE_DT":"09/05/2023","DOCKET_NO":"WEVA 2024-0078","DECISION_DT":"07/12/2024","CFR_STANDARD_CODE":"77.1605(k)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"518.00","DECISION_PENALTY_AMT":"518.00","sourceDate":"2023-09-05"},{"SOURCE_ROW_NUMBER":"165904","CITATION_NO":"9596334","CITATION_ISSUE_DT":"09/05/2023","DOCKET_NO":"WEVA 2024-0078","DECISION_DT":"07/12/2024","CFR_STANDARD_CODE":"77.1103(d)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"143.00","DECISION_PENALTY_AMT":"143.00","sourceDate":"2023-09-05"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":326,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":80,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2023-04-05","lastDate":"2023-11-09","metrics":{"recentRows":2,"currentOperatorTenures":1,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":41,"firstDate":"2023-06-07","lastDate":"2026-10-01","metrics":{"inspectors":109,"recentRows":41,"onSiteHours":1844.25,"inspectionHours":2464.5,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"454248","EVENT_NO":"7047957","INSPECTION_BEGIN_DT":"10/01/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"24.5","SUM_TOTAL_ON_SITE_HOURS":"19","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"161227","EVENT_NO":"F02B536","INSPECTION_BEGIN_DT":"09/29/2026","INSPECTION_END_DT":"09/30/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"13","sourceDate":"2026-09-29"},{"SOURCE_ROW_NUMBER":"93107","EVENT_NO":"F02293C","INSPECTION_BEGIN_DT":"08/27/2026","INSPECTION_END_DT":"08/27/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1.25","sourceDate":"2026-08-27"},{"SOURCE_ROW_NUMBER":"466369","EVENT_NO":"F022939","INSPECTION_BEGIN_DT":"08/13/2026","INSPECTION_END_DT":"08/13/2026","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"15.5","SUM_TOTAL_ON_SITE_HOURS":"11.5","sourceDate":"2026-08-13"},{"SOURCE_ROW_NUMBER":"337700","EVENT_NO":"F022937","INSPECTION_BEGIN_DT":"08/04/2026","INSPECTION_END_DT":"08/04/2026","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"17.25","SUM_TOTAL_ON_SITE_HOURS":"13","sourceDate":"2026-08-04"},{"SOURCE_ROW_NUMBER":"307938","EVENT_NO":"F00E0D3","INSPECTION_BEGIN_DT":"07/06/2026","INSPECTION_END_DT":"08/24/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"8","SUM_TOTAL_INSP_HOURS":"279.5","SUM_TOTAL_ON_SITE_HOURS":"223.75","sourceDate":"2026-07-06"},{"SOURCE_ROW_NUMBER":"976190","EVENT_NO":"F007655","INSPECTION_BEGIN_DT":"06/11/2026","INSPECTION_END_DT":"06/11/2026","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"9.25","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"568702","EVENT_NO":"F03DF6C","INSPECTION_BEGIN_DT":"04/03/2026","INSPECTION_END_DT":"04/03/2026","ACTIVITY_CODE":"E03","ACTIVITY":"103 (g) Written Notification Hazard Complaint Inspectio","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"7.25","sourceDate":"2026-04-03"},{"SOURCE_ROW_NUMBER":"1050529","EVENT_NO":"7048877","INSPECTION_BEGIN_DT":"04/01/2026","INSPECTION_END_DT":"06/26/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"10","SUM_TOTAL_INSP_HOURS":"360.75","SUM_TOTAL_ON_SITE_HOURS":"281","sourceDate":"2026-04-01"},{"SOURCE_ROW_NUMBER":"874440","EVENT_NO":"F011544","INSPECTION_BEGIN_DT":"03/24/2026","INSPECTION_END_DT":"04/22/2026","ACTIVITY_CODE":"E07","ACTIVITY":"Non-Fatal Accident Investigation","NBR_INSPECTOR":"6","SUM_TOTAL_INSP_HOURS":"91.75","SUM_TOTAL_ON_SITE_HOURS":"60","sourceDate":"2026-03-24"},{"SOURCE_ROW_NUMBER":"1071156","EVENT_NO":"F025BD5","INSPECTION_BEGIN_DT":"03/17/2026","INSPECTION_END_DT":"03/17/2026","ACTIVITY_CODE":"E03","ACTIVITY":"103 (g) Written Notification Hazard Complaint Inspectio","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"11.5","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2026-03-17"},{"SOURCE_ROW_NUMBER":"265943","EVENT_NO":"F00EAFA","INSPECTION_BEGIN_DT":"03/11/2026","INSPECTION_END_DT":"03/11/2026","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2026-03-11"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":26,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2026-Q2":{"hours":21275,"employees":57,"production":80776},"2026-Q1":{"hours":29069,"employees":55,"production":87049},"2025-Q4":{"hours":28202,"employees":62,"production":76206},"2025-Q3":{"hours":31070,"employees":62,"production":97765},"2025-Q2":{"hours":28660,"employees":57,"production":94228},"2025-Q1":{"hours":24263,"employees":60,"production":57100},"2024-Q4":{"hours":18166,"employees":61,"production":67947},"2024-Q3":{"hours":15598,"employees":48,"production":42865},"2024-Q2":{"hours":15893,"employees":52,"production":58358},"2024-Q1":{"hours":22207,"employees":49,"production":29904},"2023-Q4":{"hours":3047,"employees":15,"production":1480},"2023-Q3":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":8,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2023":{"hours":3047,"employees":15,"production":1480},"2024":{"hours":71864,"employees":52,"production":199074},"2025":{"hours":112195,"employees":60,"production":325299},"2026":{"hours":50344,"employees":57,"production":167825}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":45,"firstDate":"2023-06-14","lastDate":"2026-05-28","metrics":{"recentRows":45,"doseOver100":2,"actDoseTotal":2426,"pelDoseTotal":1763},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"272120","EVENT_NO":"7048877","SURVEY_DATE":"05/28/2026","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"40","ACT_DOSE_85":"37","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2026-05-28"},{"SOURCE_ROW_NUMBER":"272119","EVENT_NO":"7048877","SURVEY_DATE":"05/28/2026","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","ACT_DOSE_85":"26","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2026-05-28"},{"SOURCE_ROW_NUMBER":"272118","EVENT_NO":"7048877","SURVEY_DATE":"05/28/2026","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","ACT_DOSE_85":"38","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2026-05-28"},{"SOURCE_ROW_NUMBER":"272117","EVENT_NO":"7048877","SURVEY_DATE":"05/28/2026","OCCUPATION_CD_DESC":"DISPATCHER","MACHINE_CD":"40","ACT_DOSE_85":"11","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2026-05-28"},{"SOURCE_ROW_NUMBER":"272116","EVENT_NO":"7048877","SURVEY_DATE":"05/28/2026","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","ACT_DOSE_85":"33","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2026-05-28"},{"SOURCE_ROW_NUMBER":"272135","EVENT_NO":"F02EB97","SURVEY_DATE":"01/07/2026","OCCUPATION_CD_DESC":"SCOOP OPERATOR","MACHINE_CD":"40","ACT_DOSE_85":"57","PEL_DOSE_90":"33","SURVEY_TYPE":"I","sourceDate":"2026-01-07"},{"SOURCE_ROW_NUMBER":"272134","EVENT_NO":"F02EB97","SURVEY_DATE":"01/07/2026","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"64","PEL_DOSE_90":"47","SURVEY_TYPE":"I","sourceDate":"2026-01-07"},{"SOURCE_ROW_NUMBER":"272133","EVENT_NO":"F02EB97","SURVEY_DATE":"01/07/2026","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"57","PEL_DOSE_90":"31","SURVEY_TYPE":"I","sourceDate":"2026-01-07"},{"SOURCE_ROW_NUMBER":"272132","EVENT_NO":"F02EB97","SURVEY_DATE":"01/07/2026","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"113","PEL_DOSE_90":"89","SURVEY_TYPE":"I","sourceDate":"2026-01-07"},{"SOURCE_ROW_NUMBER":"272131","EVENT_NO":"F02EB97","SURVEY_DATE":"01/07/2026","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"83","PEL_DOSE_90":"68","SURVEY_TYPE":"I","sourceDate":"2026-01-07"},{"SOURCE_ROW_NUMBER":"272130","EVENT_NO":"F02EB97","SURVEY_DATE":"01/07/2026","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","ACT_DOSE_85":"36","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2026-01-07"},{"SOURCE_ROW_NUMBER":"272129","EVENT_NO":"F02EB97","SURVEY_DATE":"01/07/2026","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"86","PEL_DOSE_90":"65","SURVEY_TYPE":"I","sourceDate":"2026-01-07"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":55,"firstDate":"2024-02-27","lastDate":"2026-07-29","metrics":{"recentRows":55,"voidSamples":0,"maxQuartzPct":7.8,"validSamples":55,"quartzPctTotal":218},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"124933","CASSETTE_NO":"58593591","SAMPLE_DT":"07/29/2026","QUARTZ_PCT":"04.4","QUARTZ_MICROGRAMS":"12","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-29"},{"SOURCE_ROW_NUMBER":"120108","CASSETTE_NO":"58593546","SAMPLE_DT":"07/29/2026","QUARTZ_PCT":"06.5","QUARTZ_MICROGRAMS":"17","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-29"},{"SOURCE_ROW_NUMBER":"99848","CASSETTE_NO":"58593577","SAMPLE_DT":"07/29/2026","QUARTZ_PCT":"03.1","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-29"},{"SOURCE_ROW_NUMBER":"149257","CASSETTE_NO":"58593321","SAMPLE_DT":"06/01/2026","QUARTZ_PCT":"03.8","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-06-01"},{"SOURCE_ROW_NUMBER":"137118","CASSETTE_NO":"58593337","SAMPLE_DT":"06/01/2026","QUARTZ_PCT":"05.3","QUARTZ_MICROGRAMS":"18","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-06-01"},{"SOURCE_ROW_NUMBER":"125872","CASSETTE_NO":"58593203","SAMPLE_DT":"06/01/2026","QUARTZ_PCT":"07.8","QUARTZ_MICROGRAMS":"14","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-06-01"},{"SOURCE_ROW_NUMBER":"111173","CASSETTE_NO":"58593648","SAMPLE_DT":"06/01/2026","QUARTZ_PCT":"03.0","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-06-01"},{"SOURCE_ROW_NUMBER":"99991","CASSETTE_NO":"58593663","SAMPLE_DT":"06/01/2026","QUARTZ_PCT":"04.0","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-06-01"},{"SOURCE_ROW_NUMBER":"167984","CASSETTE_NO":"58593649","SAMPLE_DT":"05/28/2026","QUARTZ_PCT":"01.8","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-05-28"},{"SOURCE_ROW_NUMBER":"112725","CASSETTE_NO":"58569365","SAMPLE_DT":"01/07/2026","QUARTZ_PCT":"03.7","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-01-07"},{"SOURCE_ROW_NUMBER":"105294","CASSETTE_NO":"58569369","SAMPLE_DT":"01/07/2026","QUARTZ_PCT":"02.9","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-01-07"},{"SOURCE_ROW_NUMBER":"68621","CASSETTE_NO":"58569574","SAMPLE_DT":"01/07/2026","QUARTZ_PCT":"00.8","QUARTZ_MICROGRAMS":"1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-01-07"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":258,"firstDate":"2023-06-07","lastDate":"2026-10-06","metrics":{"ss":66,"amountDue":71517,"contested":0,"amountPaid":60961,"recentRows":258,"section104d":1,"unterminated":3,"proposedPenalty":72632},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2997689","VIOLATION_NO":"5134921","VIOLATION_ISSUE_DT":"10/06/2026","SIG_SUB":"N","PART_SECTION":"75.1722(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2997688","VIOLATION_NO":"5134920","VIOLATION_ISSUE_DT":"10/06/2026","SIG_SUB":"N","PART_SECTION":"75.604(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2997687","VIOLATION_NO":"5134919","VIOLATION_ISSUE_DT":"10/06/2026","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2997686","VIOLATION_NO":"5134918","VIOLATION_ISSUE_DT":"10/02/2026","SIG_SUB":"Y","PART_SECTION":"75.604(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/02/2026","CONTESTED_IND":"N","sourceDate":"2026-10-02"},{"SOURCE_ROW_NUMBER":"2997685","VIOLATION_NO":"5134917","VIOLATION_ISSUE_DT":"10/02/2026","SIG_SUB":"N","PART_SECTION":"75.515","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-10-02"},{"SOURCE_ROW_NUMBER":"2997684","VIOLATION_NO":"5134916","VIOLATION_ISSUE_DT":"10/02/2026","SIG_SUB":"N","PART_SECTION":"75.1107-13(g)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-10-02"},{"SOURCE_ROW_NUMBER":"2997683","VIOLATION_NO":"5134915","VIOLATION_ISSUE_DT":"10/02/2026","SIG_SUB":"N","PART_SECTION":"75.1719-1(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-10-02"},{"SOURCE_ROW_NUMBER":"2997682","VIOLATION_NO":"5134914","VIOLATION_ISSUE_DT":"10/02/2026","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-10-02"},{"SOURCE_ROW_NUMBER":"2997681","VIOLATION_NO":"5134912","VIOLATION_ISSUE_DT":"10/01/2026","SIG_SUB":"Y","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/01/2026","CONTESTED_IND":"N","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"2997680","VIOLATION_NO":"5134911","VIOLATION_ISSUE_DT":"10/01/2026","SIG_SUB":"N","PART_SECTION":"75.333(c)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/01/2026","CONTESTED_IND":"N","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"2997679","VIOLATION_NO":"5134910","VIOLATION_ISSUE_DT":"10/01/2026","SIG_SUB":"Y","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/02/2026","CONTESTED_IND":"N","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"2997678","VIOLATION_NO":"5134909","VIOLATION_ISSUE_DT":"10/01/2026","SIG_SUB":"N","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/01/2026","CONTESTED_IND":"N","sourceDate":"2026-10-01"}]}],"safety":{"href":"/api/v1/mines/4609649/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609649/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":{"averageEmployees":53,"companyType":"Independent Producer Operator","components":[{"averageEmployees":53,"laborHours":71864,"mineType":"Underground","productionTons":199074}],"county":"Logan","laborHours":71864,"mineName":"Jireh","mineType":"Underground","mshaId":"4609649","operatingAddress":"799 Hwy 3459, Harlan, KY 40831","operatingCompany":"Jet Coal Company, Inc.","operationType":"Mine only","productionTons":199074,"reportedRows":1,"sourceUrl":"https://www.eia.gov/coal/data/public/xls/coalpublic2024.xlsx","state":"West Virginia (Southern)","status":"Active","supplyRegion":"Appalachia Central","union":"","year":2024},"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1722","heading":"Mechanical equipment guards.","id":"75.1722","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1722","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.604","heading":"Permanent splicing of trailing cables.","id":"75.604","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.604","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"[Statutory Provisions]\n\nWhen permanent splices in trailing cables are made, they shall be:\n\n(a) Mechanically strong with adequate electrical conductivity and flexibility;\n\n(b) Effectively insulated and sealed so as to exclude moisture; and\n\n(c) Vulcanized or otherwise treated with suitable materials to provide flame-resistant qualities and good bonding to the outer jacket.\n\n(d) Made using splice kits accepted or approved by MSHA as flame resistant.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 57 FR 61223, Dec. 23, 1992]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.515","heading":"Cable fittings; suitability.","id":"75.515","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.515","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nCables shall enter metal frames of motors, splice boxes, and electric compartments only through proper fittings. When insulated wires other than cables pass through metal frames, the holes shall be substantially bushed with insulated bushings.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-13","heading":"Approval of other fire suppression devices.","id":"75.1107-13","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-13","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Notwithstanding the provisions of §§ 75.1107-1 through 75.1107-12 the District Manager for the District in which the mine is located may approve any other fire suppression system or device which provides substantially equivalent protection as would be achieved through compliance with those sections: Provided, That no such system or device shall be approved which does not meet the following minimum criteria:\n\n(a) Components shall be approved by the Secretary, or where appropriate be listed as approved by a nationally recognized agency approved by the Secretary.\n\n(b) The fire suppression equipment shall be designed to withstand the rigors of the mine environment. Where used, pressure vessels shall conform with the requirements of section 3603, 3606, 3607, 3707, and 3708 of National Fire Code No. 22 “Water Tanks for Private Fire Protection” (NFPA No. 22-1971).\n\n(c) The cover of hose of fire suppression devices, if used on the protected equipment, shall meet the flame-resistant requirements of Part 18 of this chapter (Bureau of Mines Schedule 2G).\n\n(d) Extinguishing agents shall not create a serious toxic or other hazard to the miners.\n\n(e) The electrical components of the fire suppression device shall meet the requirements for electrical components of the mining machine.\n\n(f) Where used, manual actuators for initiating the operation of the fire suppression device shall be readily accessible to the machine operator. On unattended equipment, an automatic as well as a manual actuator shall be provided.\n\n(g) On unattended equipment the fire suppression device shall operate independently of the power to the main motor (or equivalent) so it will remain operative if the circuit breakers (or other protective device) actuates. On attended equipment powered through a trailing cable the fire suppression device shall operate independently of the electrical power provided by the cable.\n\n(h) On unattended equipment, the sensor system shall have a means for checking its operative condition.\n\n(i) The fire suppression agent shall be directed at locations where the greatest potential fire hazard exists. Cable reel compartments shall receive approximately twice the quantity of extinguishing agent as each other hazardous location.\n\n(j) The rate of application of the fire suppression agent shall minimize the time for quenching and the total quantity applied shall be sufficient to quench a fire in its incipient stage.\n\n(k) The effectiveness of the quenching agent, together with the total quantity of agent and its rate of application shall provide equivalent protection to the water, dry powder, or foam systems described in §§ 75.1107-7, 75.1107-9, and 75.1107-10.\n\n(l) The fire suppression device shall be operable at all times electrical power is connected to the mining machine, except during tramming when the machine is in a ventilated passageway, the water hose if used, may be switched from one hydrant to another in a reasonable time and except in systems meeting the minimum special criteria set forth in paragraph (m) of this section.\n\n(m) Systems for attended equipment which are not continuously connected to a water supply shall not be approved unless they meet the following minimum criteria:\n\n(1) The machine shall be equipped with a firehose at least 50 feet in length which is continuously connected to the machine-mounted portion of the system.\n\n(2) Hydrants in proximity to the area where the machine is to be used shall be equipped with sufficient hose to reach the machine at any time it is connected to a power source.\n\n(3) The machine shall be used only where the operator (or other person) will always be in ventilated air uncontaminated by smoke and hot gases from the machine fire while extending the machine-mounted hose to connect with the hydrant-mounted hose.\n\n(4) The machine and hydrant hoses shall be readily accessible so that the connection between the machine-mounted hose and the hydrant hose can be made and water flow achieved in not more than 3 minutes under actual mining conditions for any location of the machine while electric power is connected.\n\n(5) The rate of water flow at the machine shall provide a minimum of 0.12 gallon of water per minute per square foot of top surface area (excluding conveyors, cutters, and gathering heads). The water shall discharge to all hazardous locations on the machine.\n\n(6) Hose, if used on the machine, in addition to meeting the flame resistant requirements for the cover of a hose provided in §§ 75.1107-3(b) and 75.1107-13(c) shall have a minimum burst pressure 4 times that of the static water pressure at the mining machine. Fabric braid hose shall have at least two braids, and wire braid hose shall have at least a single braid.\n\n(7) In addition to the hose located at the hydrant (which is intended to be connected to the hose on the machine) the firefighting equipment required by § 75.1100-2(a) shall be maintained.\n\n(8) A sufficient number of trained miners shall be kept on the section when the machine is in use to connect the machine hose to the hydrant hose and achieve water flow in not more than 3 minutes.\n\n[37 FR 15303, July 29, 1972]","occurrenceCount":1},{"chapter":"I","heading":"Illumination in working places.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1719-1","part":"75","subchapter":"O","subpart":"R","id":"75.1719-1","citation":"30 CFR 75.1719-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":2}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609649","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}