{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"4609599","name":"Quinwood No. 1 Deep Mine","status":"Abandoned","status_date":"2024-06-20","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Nicholas","nearest_town":"Leivasy","operator_id":"0153753","operator_name":"Quinwood Coal Company, LLC","controller_id":"0136721","controller_name":"Corbin  Robertson III","district":"C04","office":"Summersville WV Field Office","employees":0,"latitude":38.173611,"longitude":-80.722222},"coverage":{"contributingSources":15,"registeredSources":20,"sourceRows":791},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609599","name":"Quinwood No. 1 Deep Mine"},"operator":{"type":"operator","id":"0153753","name":"Quinwood Coal Company, LLC"},"controller":{"type":"controller","id":"0136721","name":"Corbin  Robertson III"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"0136721","name":"Corbin  Robertson III"},"object":{"type":"mine","id":"4609599","name":"Quinwood No. 1 Deep Mine"},"validFrom":"2017-06-13","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609599|0136721|2017-06-13|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0153753","name":"Quinwood Coal Company"},"object":{"type":"mine","id":"4609599","name":"Quinwood No. 1 Deep Mine"},"validFrom":"2020-11-05","validTo":"2021-04-22","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609599|0153753|2020-11-05|2021-04-22"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0136721","name":"Corbin  Robertson III"},"object":{"type":"operator","id":"0153753","name":"Quinwood Coal Company"},"validFrom":"2020-11-05","validTo":"2021-04-22","current":false,"derived":true,"evidenceMineId":"4609599","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609599|0153753|2020-11-05|0136721|2017-06-13|27556"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0176273","name":"JCS Holding Company, LLC"},"object":{"type":"mine","id":"4609599","name":"Quinwood No. 1 Deep Mine"},"validFrom":"2021-04-23","validTo":"2022-03-06","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609599|0176273|2021-04-23|2022-03-06"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C14687","name":"Jimmie R  Ryan et al"},"object":{"type":"mine","id":"4609599","name":"Quinwood No. 1 Deep Mine"},"validFrom":"2021-04-23","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609599|C14687|2021-04-23|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14687","name":"Jimmie R  Ryan et al"},"object":{"type":"operator","id":"0176273","name":"JCS Holding Company, LLC"},"validFrom":"2021-04-23","validTo":"2022-03-06","current":false,"derived":true,"evidenceMineId":"4609599","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609599|0176273|2021-04-23|C14687|2021-04-23|93618"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0153753","name":"Quinwood Coal Company, LLC"},"object":{"type":"mine","id":"4609599","name":"Quinwood No. 1 Deep Mine"},"validFrom":"2022-03-07","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609599|0153753|2022-03-07|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0136721","name":"Corbin  Robertson III"},"object":{"type":"operator","id":"0153753","name":"Quinwood Coal Company, LLC"},"validFrom":"2022-03-07","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609599","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609599|0153753|2022-03-07|0136721|2017-06-13|27557"}}],"coverage":{"historyRecords":3,"edgeCount":8,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":3,"firstDate":"2021-11-05","lastDate":"2022-10-25","metrics":{"daysLost":208,"injuries":3,"fatalities":0,"recentRows":3,"restrictedDays":17,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"115713","DOCUMENT_NO":"220223000007","ACCIDENT_DT":"10/25/2022","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Had motor hoisted to top of building. Had to pick motor up and swing to line bolt holes up. When we swung the motor the bar that the chain hoist was hooked to slid out of the bracket allowing pump motor to fall. EE's hand was caught between the pump motor and pump causing EE's hand to damaged.","sourceDate":"2022-10-25"},{"SOURCE_ROW_NUMBER":"262289","DOCUMENT_NO":"220223010001","ACCIDENT_DT":"08/26/2022","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"208","NARRATIVE":"EE was hanging miner cable on the section with 2 other EE's when EE felt a pain in EE's right arm. Later in the shift EE's fingers on EE's right hand started becoming numb. EE was using proper lifting techniques and had PPE on. The cable had tension prior to lifting.","sourceDate":"2022-08-26"},{"SOURCE_ROW_NUMBER":"21299","DOCUMENT_NO":"220213190013","ACCIDENT_DT":"11/05/2021","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Placed hand on boom arms and got caught between boom and canopy post","sourceDate":"2021-11-05"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2024-06-20","lastDate":"2024-06-20","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":115,"firstDate":"2021-10-29","lastDate":"2024-07-15","metrics":{"ss":6,"delinquent":107,"recentRows":115,"paidPenalty":20980.22,"proposedPenalty":27215,"currentAssessment":27197},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1924397","VIOLATION_NO":"9844159","ISSUE_DT":"07/15/2024","CFR_STANDARD_CD":"75.1711","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"4628.00","CURRENT_ASSESSMENT_AMT":"4628.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2024-07-15"},{"SOURCE_ROW_NUMBER":"1926562","VIOLATION_NO":"9840567","ISSUE_DT":"10/24/2023","CFR_STANDARD_CD":"70.209(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"143.00","CURRENT_ASSESSMENT_AMT":"143.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2023-10-24"},{"SOURCE_ROW_NUMBER":"1926561","VIOLATION_NO":"9840566","ISSUE_DT":"10/24/2023","CFR_STANDARD_CD":"70.208(a)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"143.00","CURRENT_ASSESSMENT_AMT":"143.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2023-10-24"},{"SOURCE_ROW_NUMBER":"1926054","VIOLATION_NO":"9840663","ISSUE_DT":"08/09/2023","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"143.00","CURRENT_ASSESSMENT_AMT":"143.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-08-09"},{"SOURCE_ROW_NUMBER":"1926053","VIOLATION_NO":"9840662","ISSUE_DT":"08/08/2023","CFR_STANDARD_CD":"75.904","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"214.00","CURRENT_ASSESSMENT_AMT":"214.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-08-08"},{"SOURCE_ROW_NUMBER":"1926052","VIOLATION_NO":"9840661","ISSUE_DT":"08/08/2023","CFR_STANDARD_CD":"75.1100-2(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"143.00","CURRENT_ASSESSMENT_AMT":"143.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-08-08"},{"SOURCE_ROW_NUMBER":"1926051","VIOLATION_NO":"9840660","ISSUE_DT":"08/08/2023","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"214.00","CURRENT_ASSESSMENT_AMT":"214.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-08-08"},{"SOURCE_ROW_NUMBER":"1926050","VIOLATION_NO":"9840659","ISSUE_DT":"08/08/2023","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"143.00","CURRENT_ASSESSMENT_AMT":"143.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-08-08"},{"SOURCE_ROW_NUMBER":"1926049","VIOLATION_NO":"9840658","ISSUE_DT":"08/07/2023","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"143.00","CURRENT_ASSESSMENT_AMT":"143.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-08-07"},{"SOURCE_ROW_NUMBER":"1926048","VIOLATION_NO":"9840657","ISSUE_DT":"08/07/2023","CFR_STANDARD_CD":"75.604(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"214.00","CURRENT_ASSESSMENT_AMT":"214.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-08-07"},{"SOURCE_ROW_NUMBER":"1926047","VIOLATION_NO":"9840656","ISSUE_DT":"08/07/2023","CFR_STANDARD_CD":"75.1107-16(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"143.00","CURRENT_ASSESSMENT_AMT":"143.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-08-07"},{"SOURCE_ROW_NUMBER":"1926046","VIOLATION_NO":"9840655","ISSUE_DT":"08/04/2023","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"143.00","CURRENT_ASSESSMENT_AMT":"143.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-08-04"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":1,"firstDate":"2023-03-14","lastDate":"2023-03-14","metrics":{"appeals":0,"decisions":1,"recentRows":1,"decisionPenalty":130,"originalPenalty":148},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"444500","VIOLATION_NO":"9242663","DOCKET_NO":"WEVA 2022-0490","DECISION_DT":"03/14/2023","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"148.00","DECISION_PENALTY_AMT":"130.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2023-03-14"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":415,"firstDate":"2021-12-21","lastDate":"2023-08-25","metrics":{"recentRows":415,"cpdmSamples":334,"voidSamples":149,"validSamples":266,"maxConcentration":5.418,"concentrationTotal":153.451},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2410785","SMP_TAKEN_DT":"8/25/2023","CONC":".107","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2023-08-25"},{"SOURCE_ROW_NUMBER":"2581742","SMP_TAKEN_DT":"8/24/2023","CONC":".68","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2023-08-24"},{"SOURCE_ROW_NUMBER":"2239214","SMP_TAKEN_DT":"8/24/2023","CONC":".852","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2023-08-24"},{"SOURCE_ROW_NUMBER":"2581834","SMP_TAKEN_DT":"8/23/2023","CONC":".893","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2023-08-23"},{"SOURCE_ROW_NUMBER":"2240253","SMP_TAKEN_DT":"8/23/2023","CONC":".259","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2023-08-23"},{"SOURCE_ROW_NUMBER":"2838069","SMP_TAKEN_DT":"8/22/2023","CONC":".33","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2023-08-22"},{"SOURCE_ROW_NUMBER":"2324961","SMP_TAKEN_DT":"8/22/2023","CONC":".198","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2023-08-22"},{"SOURCE_ROW_NUMBER":"2582636","SMP_TAKEN_DT":"8/21/2023","CONC":".023","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2023-08-21"},{"SOURCE_ROW_NUMBER":"2325326","SMP_TAKEN_DT":"8/18/2023","CONC":".04","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2023-08-18"},{"SOURCE_ROW_NUMBER":"2154329","SMP_TAKEN_DT":"8/17/2023","CONC":".203","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2023-08-17"},{"SOURCE_ROW_NUMBER":"2068362","SMP_TAKEN_DT":"8/17/2023","CONC":".155","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2023-08-17"},{"SOURCE_ROW_NUMBER":"2667676","SMP_TAKEN_DT":"8/16/2023","CONC":".182","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2023-08-16"}]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":1,"firstDate":"2022-05-23","lastDate":"2022-05-23","metrics":{"decisions":1,"ssChanged":0,"recentRows":1,"decisionPenalty":130,"proposedPenalty":148},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"106888","CITATION_NO":"9242663","CITATION_ISSUE_DT":"05/23/2022","DOCKET_NO":"WEVA 2022-0490","DECISION_DT":"03/14/2023","CFR_STANDARD_CODE":"48.6","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"148.00","DECISION_PENALTY_AMT":"130.00","sourceDate":"2022-05-23"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":58,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":14,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"2020-11-05","lastDate":"2022-03-07","metrics":{"recentRows":2,"currentOperatorTenures":1,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":25,"firstDate":"2020-10-26","lastDate":"2025-03-21","metrics":{"inspectors":62,"recentRows":24,"onSiteHours":833.25,"inspectionHours":1330.25,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"847217","EVENT_NO":"F0098DE","INSPECTION_BEGIN_DT":"03/21/2025","INSPECTION_END_DT":"03/21/2025","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2025-03-21"},{"SOURCE_ROW_NUMBER":"841","EVENT_NO":"6321333","INSPECTION_BEGIN_DT":"07/15/2024","INSPECTION_END_DT":"07/22/2024","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"18","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2024-07-15"},{"SOURCE_ROW_NUMBER":"558904","EVENT_NO":"6321329","INSPECTION_BEGIN_DT":"04/02/2024","INSPECTION_END_DT":"04/02/2024","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2024-04-02"},{"SOURCE_ROW_NUMBER":"347743","EVENT_NO":"6321316","INSPECTION_BEGIN_DT":"01/02/2024","INSPECTION_END_DT":"01/24/2024","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2024-01-02"},{"SOURCE_ROW_NUMBER":"907758","EVENT_NO":"6321707","INSPECTION_BEGIN_DT":"10/03/2023","INSPECTION_END_DT":"12/20/2023","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"88.5","SUM_TOTAL_ON_SITE_HOURS":"60.5","sourceDate":"2023-10-03"},{"SOURCE_ROW_NUMBER":"89799","EVENT_NO":"6321651","INSPECTION_BEGIN_DT":"07/03/2023","INSPECTION_END_DT":"08/18/2023","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"145","SUM_TOTAL_ON_SITE_HOURS":"105.25","sourceDate":"2023-07-03"},{"SOURCE_ROW_NUMBER":"615078","EVENT_NO":"6320040","INSPECTION_BEGIN_DT":"04/03/2023","INSPECTION_END_DT":"06/28/2023","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"153.5","SUM_TOTAL_ON_SITE_HOURS":"103.25","sourceDate":"2023-04-03"},{"SOURCE_ROW_NUMBER":"65771","EVENT_NO":"6319561","INSPECTION_BEGIN_DT":"03/01/2023","INSPECTION_END_DT":"03/01/2023","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.5","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2023-03-01"},{"SOURCE_ROW_NUMBER":"129181","EVENT_NO":"6318378","INSPECTION_BEGIN_DT":"01/30/2023","INSPECTION_END_DT":"02/16/2023","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"128.75","SUM_TOTAL_ON_SITE_HOURS":"92.75","sourceDate":"2023-01-30"},{"SOURCE_ROW_NUMBER":"177655","EVENT_NO":"6320204","INSPECTION_BEGIN_DT":"01/05/2023","INSPECTION_END_DT":"01/05/2023","ACTIVITY_CODE":"E22","ACTIVITY":"Health Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"17.75","SUM_TOTAL_ON_SITE_HOURS":"12.25","sourceDate":"2023-01-05"},{"SOURCE_ROW_NUMBER":"354692","EVENT_NO":"6317297","INSPECTION_BEGIN_DT":"10/13/2022","INSPECTION_END_DT":"10/14/2022","ACTIVITY_CODE":"E03","ACTIVITY":"103 (g) Written Notification Hazard Complaint Inspectio","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2022-10-13"},{"SOURCE_ROW_NUMBER":"780220","EVENT_NO":"6318616","INSPECTION_BEGIN_DT":"10/05/2022","INSPECTION_END_DT":"12/19/2022","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"146.5","SUM_TOTAL_ON_SITE_HOURS":"96.25","sourceDate":"2022-10-05"}]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":7,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2021":{"hours":7184,"employees":25,"production":5863},"2022":{"hours":62858,"employees":35,"production":26010},"2023":{"hours":41719,"employees":34,"production":38469}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":17,"firstDate":"2021-12-21","lastDate":"2023-02-15","metrics":{"recentRows":17,"doseOver100":4,"actDoseTotal":812,"pelDoseTotal":611},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"271596","EVENT_NO":"6318378","SURVEY_DATE":"02/15/2023","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"102","PEL_DOSE_90":"92","SURVEY_TYPE":"I","sourceDate":"2023-02-15"},{"SOURCE_ROW_NUMBER":"271602","EVENT_NO":"6320204","SURVEY_DATE":"01/05/2023","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"103","PEL_DOSE_90":"91","SURVEY_TYPE":"I","sourceDate":"2023-01-05"},{"SOURCE_ROW_NUMBER":"271601","EVENT_NO":"6318616","SURVEY_DATE":"12/14/2022","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"40","ACT_DOSE_85":"19","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2022-12-14"},{"SOURCE_ROW_NUMBER":"271600","EVENT_NO":"6318616","SURVEY_DATE":"12/14/2022","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"95","PEL_DOSE_90":"78","SURVEY_TYPE":"I","sourceDate":"2022-12-14"},{"SOURCE_ROW_NUMBER":"271599","EVENT_NO":"6318616","SURVEY_DATE":"12/14/2022","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"14","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2022-12-14"},{"SOURCE_ROW_NUMBER":"271598","EVENT_NO":"6318616","SURVEY_DATE":"12/14/2022","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"60","PEL_DOSE_90":"37","SURVEY_TYPE":"I","sourceDate":"2022-12-14"},{"SOURCE_ROW_NUMBER":"271597","EVENT_NO":"6318616","SURVEY_DATE":"12/14/2022","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"163","PEL_DOSE_90":"152","SURVEY_TYPE":"I","sourceDate":"2022-12-14"},{"SOURCE_ROW_NUMBER":"271595","EVENT_NO":"6315768","SURVEY_DATE":"12/22/2021","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"40","ACT_DOSE_85":"16","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2021-12-22"},{"SOURCE_ROW_NUMBER":"271594","EVENT_NO":"6315768","SURVEY_DATE":"12/22/2021","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"30","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2021-12-22"},{"SOURCE_ROW_NUMBER":"271593","EVENT_NO":"6315768","SURVEY_DATE":"12/22/2021","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"39","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2021-12-22"},{"SOURCE_ROW_NUMBER":"271592","EVENT_NO":"6315768","SURVEY_DATE":"12/22/2021","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"117","PEL_DOSE_90":"92","SURVEY_TYPE":"I","sourceDate":"2021-12-22"},{"SOURCE_ROW_NUMBER":"271591","EVENT_NO":"6315768","SURVEY_DATE":"12/22/2021","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"54","PEL_DOSE_90":"40","SURVEY_TYPE":"I","sourceDate":"2021-12-22"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":15,"firstDate":"2021-12-22","lastDate":"2023-07-13","metrics":{"recentRows":15,"voidSamples":0,"maxQuartzPct":15.5,"validSamples":15,"quartzPctTotal":104.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"165021","CASSETTE_NO":"58465166","SAMPLE_DT":"07/13/2023","QUARTZ_PCT":"04.6","QUARTZ_MICROGRAMS":"20","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2023-07-13"},{"SOURCE_ROW_NUMBER":"137656","CASSETTE_NO":"58465000","SAMPLE_DT":"07/13/2023","QUARTZ_PCT":"03.7","QUARTZ_MICROGRAMS":"10","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2023-07-13"},{"SOURCE_ROW_NUMBER":"111692","CASSETTE_NO":"58465181","SAMPLE_DT":"04/06/2023","QUARTZ_PCT":"06.7","QUARTZ_MICROGRAMS":"15","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2023-04-06"},{"SOURCE_ROW_NUMBER":"122124","CASSETTE_NO":"58464072","SAMPLE_DT":"02/15/2023","QUARTZ_PCT":"06.8","QUARTZ_MICROGRAMS":"22","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2023-02-15"},{"SOURCE_ROW_NUMBER":"35710","CASSETTE_NO":"58464179","SAMPLE_DT":"02/15/2023","QUARTZ_PCT":"08.6","QUARTZ_MICROGRAMS":"15","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2023-02-15"},{"SOURCE_ROW_NUMBER":"26185","CASSETTE_NO":"58463821","SAMPLE_DT":"01/05/2023","QUARTZ_PCT":"04.0","QUARTZ_MICROGRAMS":"20","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2023-01-05"},{"SOURCE_ROW_NUMBER":"24608","CASSETTE_NO":"58464108","SAMPLE_DT":"01/05/2023","QUARTZ_PCT":"08.2","QUARTZ_MICROGRAMS":"25","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2023-01-05"},{"SOURCE_ROW_NUMBER":"96770","CASSETTE_NO":"58464017","SAMPLE_DT":"12/14/2022","QUARTZ_PCT":"06.9","QUARTZ_MICROGRAMS":"19","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2022-12-14"},{"SOURCE_ROW_NUMBER":"81644","CASSETTE_NO":"58464177","SAMPLE_DT":"12/14/2022","QUARTZ_PCT":"05.4","QUARTZ_MICROGRAMS":"12","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2022-12-14"},{"SOURCE_ROW_NUMBER":"144548","CASSETTE_NO":"58448731","SAMPLE_DT":"09/21/2022","QUARTZ_PCT":"04.5","QUARTZ_MICROGRAMS":"17","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2022-09-21"},{"SOURCE_ROW_NUMBER":"26405","CASSETTE_NO":"58449147","SAMPLE_DT":"09/21/2022","QUARTZ_PCT":"15.5","QUARTZ_MICROGRAMS":"28","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2022-09-21"},{"SOURCE_ROW_NUMBER":"143671","CASSETTE_NO":"58448707","SAMPLE_DT":"06/14/2022","QUARTZ_PCT":"06.4","QUARTZ_MICROGRAMS":"12","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2022-06-14"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":115,"firstDate":"2021-10-29","lastDate":"2024-07-15","metrics":{"ss":6,"amountDue":27197,"contested":0,"amountPaid":20980.22,"recentRows":115,"section104d":0,"unterminated":0,"proposedPenalty":27215},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2995001","VIOLATION_NO":"9844159","VIOLATION_ISSUE_DT":"07/15/2024","SIG_SUB":"Y","PART_SECTION":"75.1711","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"07/25/2024","PROPOSED_PENALTY":"4628","AMOUNT_DUE":"4628","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2024-07-15"},{"SOURCE_ROW_NUMBER":"2995013","VIOLATION_NO":"9840567","VIOLATION_ISSUE_DT":"10/24/2023","SIG_SUB":"N","PART_SECTION":"70.209(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/24/2023","PROPOSED_PENALTY":"143","AMOUNT_DUE":"143","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2023-10-24"},{"SOURCE_ROW_NUMBER":"2995012","VIOLATION_NO":"9840566","VIOLATION_ISSUE_DT":"10/24/2023","SIG_SUB":"N","PART_SECTION":"70.208(a)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/24/2023","PROPOSED_PENALTY":"143","AMOUNT_DUE":"143","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2023-10-24"},{"SOURCE_ROW_NUMBER":"2995000","VIOLATION_NO":"9840663","VIOLATION_ISSUE_DT":"08/09/2023","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/09/2023","PROPOSED_PENALTY":"143","AMOUNT_DUE":"143","AMOUNT_PAID":"143","CONTESTED_IND":"N","sourceDate":"2023-08-09"},{"SOURCE_ROW_NUMBER":"2994999","VIOLATION_NO":"9840662","VIOLATION_ISSUE_DT":"08/08/2023","SIG_SUB":"N","PART_SECTION":"75.904","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/08/2023","PROPOSED_PENALTY":"214","AMOUNT_DUE":"214","AMOUNT_PAID":"214","CONTESTED_IND":"N","sourceDate":"2023-08-08"},{"SOURCE_ROW_NUMBER":"2994998","VIOLATION_NO":"9840661","VIOLATION_ISSUE_DT":"08/08/2023","SIG_SUB":"N","PART_SECTION":"75.1100-2(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/09/2023","PROPOSED_PENALTY":"143","AMOUNT_DUE":"143","AMOUNT_PAID":"143","CONTESTED_IND":"N","sourceDate":"2023-08-08"},{"SOURCE_ROW_NUMBER":"2994997","VIOLATION_NO":"9840660","VIOLATION_ISSUE_DT":"08/08/2023","SIG_SUB":"N","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/09/2023","PROPOSED_PENALTY":"214","AMOUNT_DUE":"214","AMOUNT_PAID":"214","CONTESTED_IND":"N","sourceDate":"2023-08-08"},{"SOURCE_ROW_NUMBER":"2994996","VIOLATION_NO":"9840659","VIOLATION_ISSUE_DT":"08/08/2023","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/09/2023","PROPOSED_PENALTY":"143","AMOUNT_DUE":"143","AMOUNT_PAID":"143","CONTESTED_IND":"N","sourceDate":"2023-08-08"},{"SOURCE_ROW_NUMBER":"2994995","VIOLATION_NO":"9840658","VIOLATION_ISSUE_DT":"08/07/2023","SIG_SUB":"N","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/08/2023","PROPOSED_PENALTY":"143","AMOUNT_DUE":"143","AMOUNT_PAID":"143","CONTESTED_IND":"N","sourceDate":"2023-08-07"},{"SOURCE_ROW_NUMBER":"2994994","VIOLATION_NO":"9840657","VIOLATION_ISSUE_DT":"08/07/2023","SIG_SUB":"N","PART_SECTION":"75.604(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/07/2023","PROPOSED_PENALTY":"214","AMOUNT_DUE":"214","AMOUNT_PAID":"214","CONTESTED_IND":"N","sourceDate":"2023-08-07"},{"SOURCE_ROW_NUMBER":"2994993","VIOLATION_NO":"9840656","VIOLATION_ISSUE_DT":"08/07/2023","SIG_SUB":"N","PART_SECTION":"75.1107-16(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/07/2023","PROPOSED_PENALTY":"143","AMOUNT_DUE":"143","AMOUNT_PAID":"143","CONTESTED_IND":"N","sourceDate":"2023-08-07"},{"SOURCE_ROW_NUMBER":"2994992","VIOLATION_NO":"9840655","VIOLATION_ISSUE_DT":"08/04/2023","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/07/2023","PROPOSED_PENALTY":"143","AMOUNT_DUE":"143","AMOUNT_PAID":"143","CONTESTED_IND":"N","sourceDate":"2023-08-04"}]}],"safety":{"href":"/api/v1/mines/4609599/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609599/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Sealing of mines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1711","part":"75","subchapter":"O","subpart":"R","id":"75.1711","citation":"30 CFR 75.1711","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 70.209","heading":"Quarterly sampling; designated areas.","id":"70.209","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-70/subpart-C/section-70.209","part":"70","partHeading":"PART 70—MANDATORY HEALTH STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Sampling Procedures","text":"As of April 14, 2025:\n\n(a) The operator shall sample quarterly each designated area (DA) on consecutive production shifts until five valid representative samples are taken. The quarterly periods are:\n\n(1) January 1-March 31\n\n(2) April 1-June 30\n\n(3) July 1-September 30\n\n(4) October 1-December 31.\n\n(b) [Reserved]\n\n(c) When a valid representative sample taken in accordance with this section meets or exceeds the ECV in table 1 to this section that corresponds to the particular sampling device used, the operator shall:\n\n(1) Make approved respiratory equipment available to affected miners in accordance with § 72.700 of this chapter;\n\n(2) Immediately take corrective action to lower the concentration of respirable dust to at or below the respirable dust standard; and\n\n(3) Make a record of the corrective actions taken. The record shall be certified by the mine foreman or equivalent mine official, no later than the end of the mine foreman's or equivalent official's next regularly scheduled working shift. The record shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration. Such records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(d) Noncompliance with the standard is demonstrated during the sampling period when:\n\n(1) Two or more valid representative samples meet or exceed the ECV in table 1 to this section that corresponds to the particular sampling device used; or\n\n(2) The average for all valid representative samples meets or exceeds the ECV in table 1 to this section that corresponds to the particular sampling device used.\n\n(e) Unless otherwise directed by the District Manager, upon issuance of a citation for a violation of the standard, paragraph (a) of this section shall not apply to that DA until the violation is abated and the citation is terminated in accordance with paragraphs (e) and (f) of this section.\n\n(f) Upon issuance of a citation for a violation of the standard, the operator shall take the following actions sequentially:\n\n(1) Make approved respiratory equipment available to affected miners in accordance with § 72.700 of this chapter;\n\n(2) Immediately take corrective action to lower the concentration of respirable coal mine dust to at or below the standard; and\n\n(3) Make a record of the corrective actions taken. The record shall be certified by the mine foreman or equivalent mine official, no later than the end of the mine foreman's or equivalent official's next regularly scheduled working shift. The record shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration. Such records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(4) Begin sampling, within 8 calendar days after the date the citation is issued, the environment of the affected DA on consecutive normal production shifts until five valid representative samples are taken.\n\n(g) A citation for a violation of the standard shall be terminated by MSHA when:\n\n(1) Each of the five valid representative samples is at or below the standard; and\n\n(2) The operator has submitted to the District Manager revised dust control parameters as part of the mine ventilation plan applicable to the DA in the citation, and the changes have been approved by the District Manager. The revised parameters shall reflect the control measures used by the operator to abate the violation.\n\nTable 1 to § 70.209—Excessive Concentration Values (ECV) Based on a Single Sample, Two Samples, or the Average of Five or Fifteen Full-Shift CMDPSU/CPDM Concentration Measurements Section Samples ECV (mg/m3) CMDPSU CPDM 70.209 (c) 70.100(a)—Single sample 1.79 1.70 70.100(b)—Single sample 0.74 0.57 70.209(d)(1) 70.100(a)—2 or more samples 1.79 1.70 70.100(b)—2 or more samples 0.74 0.57 70.209(d)(2) 70.100(a)—5 sample average 1.63 1.59 70.100(b)—5 sample average 0.61 0.53 70.209(d)(2) 70.100(a)—15 sample average 1.58 1.56 70.100(b)—15 sample average 0.57 0.52 70.209(g)(1) 70.100(a)—Each of 5 samples 1.79 1.70 70.100(b)—Each of 5 samples 0.74 0.57\n\n[89 FR 28475, 28476, Apr. 18, 2024]","occurrenceCount":1},{"chapter":"I","heading":"Quarterly sampling; mechanized mining units.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-70/subpart-C/section-70.208","part":"70","subchapter":"O","subpart":"C","id":"70.208","citation":"30 CFR 70.208","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 70—MANDATORY HEALTH STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.904","heading":"Identification of circuit breakers.","id":"75.904","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-J/section-75.904","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"J","subpartHeading":"Subpart J—Underground Low- and Medium-Voltage Alternating Current Circuits","text":"[Statutory Provisions]\n\nCircuit breakers shall be marked for identification.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.604","heading":"Permanent splicing of trailing cables.","id":"75.604","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.604","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"[Statutory Provisions]\n\nWhen permanent splices in trailing cables are made, they shall be:\n\n(a) Mechanically strong with adequate electrical conductivity and flexibility;\n\n(b) Effectively insulated and sealed so as to exclude moisture; and\n\n(c) Vulcanized or otherwise treated with suitable materials to provide flame-resistant qualities and good bonding to the outer jacket.\n\n(d) Made using splice kits accepted or approved by MSHA as flame resistant.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 57 FR 61223, Dec. 23, 1992]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-16","heading":"Inspection of fire suppression devices.","id":"75.1107-16","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-16","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) All fire suppression devices shall be visually inspected at least once each week by a person qualified to make such inspections.\n\n(b) Each fire suppression device shall be tested and maintained in accordance with the requirements specified in the appropriate National Fire Code listed as follows for the type and kind of device used:\n\nNational Fire Code No. 11A “High Expansion Foam Systems” (NFPA No. 11A—1970). National Fire Code No. 13A “Care and Maintenance of Sprinkler Systems” (NFPA No. 13A—1971). National Fire Code No. 15 “Water Spray Fixed Systems for Fire Protection” (NFPA No. 15—1969). National Fire Code No. 17 “Dry Chemical Extinguishing Systems” (NFPA No. 17—1969). National Fire Code No. 72A “Local Protective Signaling Systems” (NFPA No. 72A—1967). National Fire Code No. 198 “Care of Fire Hose” (NFPA No. 198—1969).\n\n(c) A record of the inspections required by this section shall be maintained by the operator. The record of the weekly inspections may be maintained at an appropriate location by each fire suppression device.\n\n[37 FR 15304, July 29, 1972, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609599","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}