{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4609528","name":"Buffalo Deep Mine","status":"Abandoned","status_date":"2020-07-01","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Logan","nearest_town":"Man","operator_id":"0135215","operator_name":"Hampden Coal LLC","controller_id":"0158381","controller_name":"Sev.en Global Investments a.s.","district":"C04","office":"Beckley District","employees":0,"latitude":37.791389,"longitude":-81.823889},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":2958},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609528","name":"Buffalo Deep Mine"},"operator":{"type":"operator","id":"0135215","name":"Hampden Coal LLC"},"controller":{"type":"controller","id":"0158381","name":"Sev.en Global Investments a.s."},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"0109461","name":"Blackhawk Mining LLC"},"object":{"type":"mine","id":"4609528","name":"Buffalo Deep Mine"},"validFrom":"2014-09-01","validTo":"2020-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609528|0109461|2014-09-01|2020-05-31"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0135215","name":"Hampden Coal LLC"},"object":{"type":"mine","id":"4609528","name":"Buffalo Deep Mine"},"validFrom":"2017-03-15","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609528|0135215|2017-03-15|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0109461","name":"Blackhawk Mining LLC"},"object":{"type":"operator","id":"0135215","name":"Hampden Coal LLC"},"validFrom":"2017-03-15","validTo":"2020-05-31","current":false,"derived":true,"evidenceMineId":"4609528","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609528|0135215|2017-03-15|0109461|2014-09-01|19873"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0158381","name":"Sev.en Global Investments a.s."},"object":{"type":"mine","id":"4609528","name":"Buffalo Deep Mine"},"validFrom":"2020-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609528|0158381|2020-06-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0158381","name":"Sev.en Global Investments a.s."},"object":{"type":"operator","id":"0135215","name":"Hampden Coal LLC"},"validFrom":"2020-06-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609528","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609528|0135215|2017-03-15|0158381|2020-06-01|32888"}}],"coverage":{"historyRecords":2,"edgeCount":5,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":25,"firstDate":"2017-05-11","lastDate":"2019-10-20","metrics":{"daysLost":2428,"injuries":25,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"214879","DOCUMENT_NO":"220192970024","ACCIDENT_DT":"10/20/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"47","NARRATIVE":"Employee stated that employee and a co-worker were loading top belt structure into a scoop bucket and the structure twisted and smashed employee's right hand index finger.","sourceDate":"2019-10-20"},{"SOURCE_ROW_NUMBER":"81504","DOCUMENT_NO":"220192970014","ACCIDENT_DT":"10/17/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in wielding or throwing objects","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"47","NARRATIVE":"Employee stated that they were in the process of pulling miner cable loop out from under the belt drift to rack on # 1 miner, when they threw a loop of cable on their shoulder they felt a sharp pain towards the middle of their back towards their spine.","sourceDate":"2019-10-17"},{"SOURCE_ROW_NUMBER":"227772","DOCUMENT_NO":"220192520026","ACCIDENT_DT":"08/30/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Section foreman, Bullgang foreman, Labor foreman, Leadman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"81","NARRATIVE":"Employee stated that employee was attempting to pull a P-40 Pump out of the mud when employee felt a pain in employee's back.","sourceDate":"2019-08-30"},{"SOURCE_ROW_NUMBER":"236396","DOCUMENT_NO":"220192250011","ACCIDENT_DT":"08/08/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Greaser, Grease man, Oiler, Lube man, Dragline oiler","NO_INJURIES":"1","DAYS_LOST":"75","NARRATIVE":"Employee stated that they were attempting to carry empty oil cans from the feeder through the left buggy dump when they stepped in a hole and felt pain in their left knee.","sourceDate":"2019-08-08"},{"SOURCE_ROW_NUMBER":"219199","DOCUMENT_NO":"220192250025","ACCIDENT_DT":"08/07/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"6","NARRATIVE":"Employee stated was walking back to the section in the #7 Entry (Return) when employee stepped in a hole and felt a pain in back.","sourceDate":"2019-08-07"},{"SOURCE_ROW_NUMBER":"106992","DOCUMENT_NO":"220192060091","ACCIDENT_DT":"07/16/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"80","NARRATIVE":"Employee stated that was attempting to remove a top roller from the belt line when EE felt pain in back.","sourceDate":"2019-07-16"},{"SOURCE_ROW_NUMBER":"8392","DOCUMENT_NO":"220191840025","ACCIDENT_DT":"06/28/2019","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee stated that IE was attempting to load a shuttle car when the car became hooked on the cable hook of the boom.  When the shuttle car pulled away from the miner, the hook broke off the miner.  IE stated IE picked up the hook to toss it against the rib and was cut by a bur on the hook.","sourceDate":"2019-06-28"},{"SOURCE_ROW_NUMBER":"42724","DOCUMENT_NO":"220191710034","ACCIDENT_DT":"06/10/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Greaser, Grease man, Oiler, Lube man, Dragline oiler","NO_INJURIES":"1","DAYS_LOST":"130","NARRATIVE":"Employee stated was attempting to service the CM when the employee slipped on a slick rock and leg slid under the back of the machine.  This caused pain in left knee.","sourceDate":"2019-06-10"},{"SOURCE_ROW_NUMBER":"120054","DOCUMENT_NO":"220191630016","ACCIDENT_DT":"06/03/2019","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee stated that when attempting to open the inby set of airlock doors near the section, they attempted to grab the top of the door to keep it from slamming against the rib.  this caused them to get a finger caught between the door and a roof bolt in the mine roof.","sourceDate":"2019-06-03"},{"SOURCE_ROW_NUMBER":"98529","DOCUMENT_NO":"220191650008","ACCIDENT_DT":"06/03/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Master mechanic, Foreman, Supervisor","NO_INJURIES":"1","DAYS_LOST":"135","NARRATIVE":"Employee was attempting to drop the miner cable during a power move when their foot became stuck in the mud.  while dropping the cable they twisted and felt a pain in the lower back and left knee.","sourceDate":"2019-06-03"},{"SOURCE_ROW_NUMBER":"154605","DOCUMENT_NO":"220191410005","ACCIDENT_DT":"05/18/2019","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"STRIKING OR BUMPING","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee stated that when they attempted to turn and duck underneath the canopy of the bolting machine, they struck their face on a roof bolt plate that was hanging over the edge of the bolt tray.  This caused a laceration to the right cheek that required sutures.  The employee did not miss any scheduled work due to this incident.","sourceDate":"2019-05-18"},{"SOURCE_ROW_NUMBER":"201847","DOCUMENT_NO":"220191260030","ACCIDENT_DT":"04/27/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Scoop tram operator, Load/Haul/Dump operator","NO_INJURIES":"1","DAYS_LOST":"4","NARRATIVE":"Employee stated that as EE was attempting to raise the battery lid on the scoop, the lid slipped and caught EE's left ring finger between the frame of the battery and the battery lid.  This caused a laceration and a fracture to the finger.","sourceDate":"2019-04-27"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2020-07-01","lastDate":"2020-07-01","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":336,"firstDate":"2017-05-10","lastDate":"2019-09-25","metrics":{"ss":73,"delinquent":321,"recentRows":0,"paidPenalty":212704,"proposedPenalty":276751,"currentAssessment":212704},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2790769","VIOLATION_NO":"9226538","ISSUE_DT":"09/25/2019","CFR_STANDARD_CD":"75.605","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"2790768","VIOLATION_NO":"9226537","ISSUE_DT":"09/25/2019","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"3241.00","CURRENT_ASSESSMENT_AMT":"1059.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"2790767","VIOLATION_NO":"9226536","ISSUE_DT":"09/25/2019","CFR_STANDARD_CD":"75.515","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"230.00","CURRENT_ASSESSMENT_AMT":"230.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"2790766","VIOLATION_NO":"9226535","ISSUE_DT":"09/25/2019","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"514.00","CURRENT_ASSESSMENT_AMT":"514.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"2790765","VIOLATION_NO":"9226534","ISSUE_DT":"09/25/2019","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"2790764","VIOLATION_NO":"9225641","ISSUE_DT":"09/25/2019","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2006.00","CURRENT_ASSESSMENT_AMT":"655.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"2790763","VIOLATION_NO":"9225640","ISSUE_DT":"09/25/2019","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"293.00","CURRENT_ASSESSMENT_AMT":"293.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"2790762","VIOLATION_NO":"9225639","ISSUE_DT":"09/25/2019","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"270.00","CURRENT_ASSESSMENT_AMT":"270.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"2790761","VIOLATION_NO":"9225638","ISSUE_DT":"09/25/2019","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"154.00","CURRENT_ASSESSMENT_AMT":"154.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"2790760","VIOLATION_NO":"9225637","ISSUE_DT":"09/25/2019","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"2790759","VIOLATION_NO":"9225636","ISSUE_DT":"09/24/2019","CFR_STANDARD_CD":"75.1722(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"230.00","CURRENT_ASSESSMENT_AMT":"230.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-09-24"},{"SOURCE_ROW_NUMBER":"2790758","VIOLATION_NO":"9225635","ISSUE_DT":"09/24/2019","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"440.00","CURRENT_ASSESSMENT_AMT":"440.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-09-24"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":173,"firstDate":"2017-12-14","lastDate":"2020-03-10","metrics":{"appeals":0,"decisions":173,"recentRows":0,"decisionPenalty":169759,"originalPenalty":233806},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"419256","VIOLATION_NO":"9226535","DOCKET_NO":"WEVA 2020-0143","DECISION_DT":"03/10/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"514.00","DECISION_PENALTY_AMT":"514.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"419255","VIOLATION_NO":"9225628","DOCKET_NO":"WEVA 2020-0143","DECISION_DT":"03/10/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"604.00","DECISION_PENALTY_AMT":"604.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"419254","VIOLATION_NO":"9225627","DOCKET_NO":"WEVA 2020-0143","DECISION_DT":"03/10/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"230.00","DECISION_PENALTY_AMT":"230.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"418389","VIOLATION_NO":"9226538","DOCKET_NO":"WEVA 2020-0143","DECISION_DT":"03/10/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"121.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"418388","VIOLATION_NO":"9226537","DOCKET_NO":"WEVA 2020-0143","DECISION_DT":"03/10/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3241.00","DECISION_PENALTY_AMT":"1059.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"418387","VIOLATION_NO":"9226534","DOCKET_NO":"WEVA 2020-0143","DECISION_DT":"03/10/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"121.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"418386","VIOLATION_NO":"9225637","DOCKET_NO":"WEVA 2020-0143","DECISION_DT":"03/10/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"121.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"418334","VIOLATION_NO":"9225641","DOCKET_NO":"WEVA 2020-0143","DECISION_DT":"03/10/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2006.00","DECISION_PENALTY_AMT":"655.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"418333","VIOLATION_NO":"9225638","DOCKET_NO":"WEVA 2020-0143","DECISION_DT":"03/10/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"154.00","DECISION_PENALTY_AMT":"154.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"418332","VIOLATION_NO":"9225631","DOCKET_NO":"WEVA 2020-0143","DECISION_DT":"03/10/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"230.00","DECISION_PENALTY_AMT":"230.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"418331","VIOLATION_NO":"9225629","DOCKET_NO":"WEVA 2020-0143","DECISION_DT":"03/10/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"270.00","DECISION_PENALTY_AMT":"270.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"417203","VIOLATION_NO":"9226536","DOCKET_NO":"WEVA 2020-0143","DECISION_DT":"03/10/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"230.00","DECISION_PENALTY_AMT":"230.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-03-10"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":1522,"firstDate":"2017-06-14","lastDate":"2019-10-07","metrics":{"recentRows":0,"cpdmSamples":1367,"voidSamples":471,"validSamples":1051,"maxConcentration":24.918,"concentrationTotal":722.582},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2890176","SMP_TAKEN_DT":"10/7/2019","CONC":".663","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-10-07"},{"SOURCE_ROW_NUMBER":"2805361","SMP_TAKEN_DT":"10/7/2019","CONC":".632","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-10-07"},{"SOURCE_ROW_NUMBER":"2634802","SMP_TAKEN_DT":"10/7/2019","CONC":".414","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-10-07"},{"SOURCE_ROW_NUMBER":"2634278","SMP_TAKEN_DT":"10/7/2019","CONC":".373","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-10-07"},{"SOURCE_ROW_NUMBER":"1050419","CASS_NUM":"58352152","SMP_TAKEN_DT":"9/24/2019","CONC":".288","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOTORMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2019-09-24"},{"SOURCE_ROW_NUMBER":"1782558","SMP_TAKEN_DT":"9/16/2019","CONC":".434","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOTORMAN","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-09-16"},{"SOURCE_ROW_NUMBER":"2464048","SMP_TAKEN_DT":"9/15/2019","CONC":".214","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-09-15"},{"SOURCE_ROW_NUMBER":"1952626","SMP_TAKEN_DT":"9/15/2019","CONC":".509","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-09-15"},{"SOURCE_ROW_NUMBER":"2378814","SMP_TAKEN_DT":"9/14/2019","CONC":".049","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-09-14"},{"SOURCE_ROW_NUMBER":"2293928","SMP_TAKEN_DT":"9/14/2019","CONC":".146","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-09-14"},{"SOURCE_ROW_NUMBER":"2719955","SMP_TAKEN_DT":"9/13/2019","CONC":".104","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-09-13"},{"SOURCE_ROW_NUMBER":"1782555","SMP_TAKEN_DT":"9/13/2019","CONC":".375","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOTORMAN","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-09-13"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":10,"firstDate":"2017-06-28","lastDate":"2019-04-02","metrics":{"linkedIssuances":10},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":173,"firstDate":"2017-05-10","lastDate":"2019-09-25","metrics":{"decisions":173,"ssChanged":12,"recentRows":0,"decisionPenalty":169759,"proposedPenalty":233806},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"444871","CITATION_NO":"9226536","CITATION_ISSUE_DT":"09/25/2019","DOCKET_NO":"WEVA 2020-0143","DECISION_DT":"03/10/2020","CFR_STANDARD_CODE":"75.515","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"230.00","DECISION_PENALTY_AMT":"230.00","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"385081","CITATION_NO":"9225640","CITATION_ISSUE_DT":"09/25/2019","DOCKET_NO":"WEVA 2020-0143","DECISION_DT":"03/10/2020","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"293.00","DECISION_PENALTY_AMT":"293.00","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"332733","CITATION_NO":"9226535","CITATION_ISSUE_DT":"09/25/2019","DOCKET_NO":"WEVA 2020-0143","DECISION_DT":"03/10/2020","CFR_STANDARD_CODE":"75.503","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"514.00","DECISION_PENALTY_AMT":"514.00","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"271759","CITATION_NO":"9226537","CITATION_ISSUE_DT":"09/25/2019","DOCKET_NO":"WEVA 2020-0143","DECISION_DT":"03/10/2020","CFR_STANDARD_CODE":"75.517","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3241.00","DECISION_PENALTY_AMT":"1059.00","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"270686","CITATION_NO":"9225638","CITATION_ISSUE_DT":"09/25/2019","DOCKET_NO":"WEVA 2020-0143","DECISION_DT":"03/10/2020","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"154.00","DECISION_PENALTY_AMT":"154.00","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"270685","CITATION_NO":"9226534","CITATION_ISSUE_DT":"09/25/2019","DOCKET_NO":"WEVA 2020-0143","DECISION_DT":"03/10/2020","CFR_STANDARD_CODE":"75.342(a)(4)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"121.00","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"215211","CITATION_NO":"9226538","CITATION_ISSUE_DT":"09/25/2019","DOCKET_NO":"WEVA 2020-0143","DECISION_DT":"03/10/2020","CFR_STANDARD_CODE":"75.605","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"121.00","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"162905","CITATION_NO":"9225637","CITATION_ISSUE_DT":"09/25/2019","DOCKET_NO":"WEVA 2020-0143","DECISION_DT":"03/10/2020","CFR_STANDARD_CODE":"75.342(a)(4)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"121.00","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"160185","CITATION_NO":"9225641","CITATION_ISSUE_DT":"09/25/2019","DOCKET_NO":"WEVA 2020-0143","DECISION_DT":"03/10/2020","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"2006.00","DECISION_PENALTY_AMT":"655.00","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"159364","CITATION_NO":"9225639","CITATION_ISSUE_DT":"09/25/2019","DOCKET_NO":"WEVA 2020-0143","DECISION_DT":"03/10/2020","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"270.00","DECISION_PENALTY_AMT":"270.00","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"383017","CITATION_NO":"9225636","CITATION_ISSUE_DT":"09/24/2019","DOCKET_NO":"WEVA 2020-0143","DECISION_DT":"03/10/2020","CFR_STANDARD_CODE":"75.1722(c)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"230.00","DECISION_PENALTY_AMT":"230.00","sourceDate":"2019-09-24"},{"SOURCE_ROW_NUMBER":"159363","CITATION_NO":"9225635","CITATION_ISSUE_DT":"09/24/2019","DOCKET_NO":"WEVA 2020-0143","DECISION_DT":"03/10/2020","CFR_STANDARD_CODE":"75.517","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"440.00","DECISION_PENALTY_AMT":"440.00","sourceDate":"2019-09-24"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":161,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":33,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2017-03-15","lastDate":"2017-03-15","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":45,"firstDate":"2017-04-12","lastDate":"2020-07-01","metrics":{"inspectors":103,"recentRows":0,"onSiteHours":1439.25,"inspectionHours":2506.5,"inspectionSamples":204},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"344868","EVENT_NO":"7016171","INSPECTION_BEGIN_DT":"07/01/2020","INSPECTION_END_DT":"07/01/2020","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2020-07-01"},{"SOURCE_ROW_NUMBER":"960776","EVENT_NO":"7015192","INSPECTION_BEGIN_DT":"03/27/2020","INSPECTION_END_DT":"04/02/2020","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2020-03-27"},{"SOURCE_ROW_NUMBER":"704321","EVENT_NO":"7015183","INSPECTION_BEGIN_DT":"01/07/2020","INSPECTION_END_DT":"01/08/2020","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2020-01-07"},{"SOURCE_ROW_NUMBER":"58728","EVENT_NO":"7009754","INSPECTION_BEGIN_DT":"10/01/2019","INSPECTION_END_DT":"12/12/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"26.5","SUM_TOTAL_ON_SITE_HOURS":"15.25","sourceDate":"2019-10-01"},{"SOURCE_ROW_NUMBER":"1047292","EVENT_NO":"7008470","INSPECTION_BEGIN_DT":"07/30/2019","INSPECTION_END_DT":"07/30/2019","ACTIVITY_CODE":"E22","ACTIVITY":"Health Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2019-07-30"},{"SOURCE_ROW_NUMBER":"2082","EVENT_NO":"7002740","INSPECTION_BEGIN_DT":"07/03/2019","INSPECTION_END_DT":"09/30/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"6","SUM_TOTAL_INSP_HOURS":"159","SUM_TOTAL_ON_SITE_HOURS":"105.75","sourceDate":"2019-07-03"},{"SOURCE_ROW_NUMBER":"391265","EVENT_NO":"7002737","INSPECTION_BEGIN_DT":"04/01/2019","INSPECTION_END_DT":"06/27/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"176","SUM_TOTAL_ON_SITE_HOURS":"99.75","sourceDate":"2019-04-01"},{"SOURCE_ROW_NUMBER":"382697","EVENT_NO":"6308593","INSPECTION_BEGIN_DT":"03/22/2019","INSPECTION_END_DT":"03/26/2019","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16.5","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2019-03-22"},{"SOURCE_ROW_NUMBER":"246924","EVENT_NO":"6308594","INSPECTION_BEGIN_DT":"03/22/2019","INSPECTION_END_DT":"03/27/2019","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"21.5","SUM_TOTAL_ON_SITE_HOURS":"11.5","sourceDate":"2019-03-22"},{"SOURCE_ROW_NUMBER":"1144000","EVENT_NO":"7007800","INSPECTION_BEGIN_DT":"01/09/2019","INSPECTION_END_DT":"01/10/2019","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2019-01-09"},{"SOURCE_ROW_NUMBER":"659712","EVENT_NO":"7003075","INSPECTION_BEGIN_DT":"01/02/2019","INSPECTION_END_DT":"03/25/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"6","SUM_TOTAL_INSP_HOURS":"217.25","SUM_TOTAL_ON_SITE_HOURS":"123.25","sourceDate":"2019-01-02"},{"SOURCE_ROW_NUMBER":"910781","EVENT_NO":"7008513","INSPECTION_BEGIN_DT":"10/28/2018","INSPECTION_END_DT":"11/08/2018","ACTIVITY_CODE":"E07","ACTIVITY":"Non-Fatal Accident Investigation","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"74.75","SUM_TOTAL_ON_SITE_HOURS":"25.5","sourceDate":"2018-10-28"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":21,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2020-Q2":{"hours":746,"employees":1,"production":0},"2020-Q1":{"hours":1356,"employees":2,"production":0},"2019-Q4":{"hours":25155,"employees":47,"production":5162},"2019-Q3":{"hours":58110,"employees":102,"production":40724},"2019-Q2":{"hours":60607,"employees":89,"production":51280},"2019-Q1":{"hours":54628,"employees":92,"production":81673},"2018-Q4":{"hours":16741,"employees":93,"production":69643},"2018-Q3":{"hours":49979,"employees":93,"production":64971},"2018-Q2":{"hours":49540,"employees":87,"production":66280},"2018-Q1":{"hours":43363,"employees":77,"production":69943},"2017-Q4":{"hours":43567,"employees":85,"production":64346},"2017-Q3":{"hours":32864,"employees":87,"production":37308}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017":{"hours":91077,"employees":69,"production":104881},"2018":{"hours":159623,"employees":88,"production":270837},"2019":{"hours":198500,"employees":82,"production":178839},"2020":{"hours":2102,"employees":2,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":37,"firstDate":"2017-06-27","lastDate":"2018-12-04","metrics":{"recentRows":0,"doseOver100":9,"actDoseTotal":2658,"pelDoseTotal":1930},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"269351","EVENT_NO":"7003072","SURVEY_DATE":"12/04/2018","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"51","PEL_DOSE_90":"29","SURVEY_TYPE":"I","sourceDate":"2018-12-04"},{"SOURCE_ROW_NUMBER":"269350","EVENT_NO":"7003072","SURVEY_DATE":"12/04/2018","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"77","PEL_DOSE_90":"61","SURVEY_TYPE":"I","sourceDate":"2018-12-04"},{"SOURCE_ROW_NUMBER":"269349","EVENT_NO":"7003072","SURVEY_DATE":"12/04/2018","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"36","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2018-12-04"},{"SOURCE_ROW_NUMBER":"269348","EVENT_NO":"7003072","SURVEY_DATE":"12/04/2018","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"73","PEL_DOSE_90":"52","SURVEY_TYPE":"I","sourceDate":"2018-12-04"},{"SOURCE_ROW_NUMBER":"269347","EVENT_NO":"7003072","SURVEY_DATE":"12/04/2018","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"148","PEL_DOSE_90":"129","SURVEY_TYPE":"I","sourceDate":"2018-12-04"},{"SOURCE_ROW_NUMBER":"269346","EVENT_NO":"7003072","SURVEY_DATE":"12/04/2018","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"25","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2018-12-04"},{"SOURCE_ROW_NUMBER":"269345","EVENT_NO":"7003072","SURVEY_DATE":"12/04/2018","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"48","PEL_DOSE_90":"48","SURVEY_TYPE":"I","sourceDate":"2018-12-04"},{"SOURCE_ROW_NUMBER":"269344","EVENT_NO":"7003072","SURVEY_DATE":"12/04/2018","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"55","PEL_DOSE_90":"40","SURVEY_TYPE":"I","sourceDate":"2018-12-04"},{"SOURCE_ROW_NUMBER":"269343","EVENT_NO":"7003072","SURVEY_DATE":"12/04/2018","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"101","PEL_DOSE_90":"87","SURVEY_TYPE":"I","sourceDate":"2018-12-04"},{"SOURCE_ROW_NUMBER":"269342","EVENT_NO":"7003072","SURVEY_DATE":"12/04/2018","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"111","PEL_DOSE_90":"93","SURVEY_TYPE":"I","sourceDate":"2018-12-04"},{"SOURCE_ROW_NUMBER":"269341","EVENT_NO":"6306790","SURVEY_DATE":"09/20/2018","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"51","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2018-09-20"},{"SOURCE_ROW_NUMBER":"269340","EVENT_NO":"6306790","SURVEY_DATE":"09/20/2018","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"98","PEL_DOSE_90":"79","SURVEY_TYPE":"I","sourceDate":"2018-09-20"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":66,"firstDate":"2017-06-14","lastDate":"2019-09-24","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":21.6,"validSamples":66,"quartzPctTotal":702.7},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"71733","CASSETTE_NO":"58352152","SAMPLE_DT":"09/24/2019","QUARTZ_PCT":"07.1","QUARTZ_MICROGRAMS":"20","OCC_CODE_DESC":"MOTORMAN","SAMPLE_TYPE_DESC":"PART 90 MINER","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-09-24"},{"SOURCE_ROW_NUMBER":"124870","CASSETTE_NO":"58352491","SAMPLE_DT":"07/17/2019","QUARTZ_PCT":"18.6","QUARTZ_MICROGRAMS":"50","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-07-17"},{"SOURCE_ROW_NUMBER":"122507","CASSETTE_NO":"58352589","SAMPLE_DT":"07/17/2019","QUARTZ_PCT":"11.6","QUARTZ_MICROGRAMS":"37","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-07-17"},{"SOURCE_ROW_NUMBER":"105077","CASSETTE_NO":"58352469","SAMPLE_DT":"07/17/2019","QUARTZ_PCT":"11.8","QUARTZ_MICROGRAMS":"15","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-07-17"},{"SOURCE_ROW_NUMBER":"80598","CASSETTE_NO":"58352564","SAMPLE_DT":"07/17/2019","QUARTZ_PCT":"15.4","QUARTZ_MICROGRAMS":"55","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-07-17"},{"SOURCE_ROW_NUMBER":"74668","CASSETTE_NO":"58352407","SAMPLE_DT":"07/17/2019","QUARTZ_PCT":"15.9","QUARTZ_MICROGRAMS":"78","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-07-17"},{"SOURCE_ROW_NUMBER":"54386","CASSETTE_NO":"58352453","SAMPLE_DT":"07/17/2019","QUARTZ_PCT":"18.9","QUARTZ_MICROGRAMS":"58","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-07-17"},{"SOURCE_ROW_NUMBER":"42222","CASSETTE_NO":"58352591","SAMPLE_DT":"07/17/2019","QUARTZ_PCT":"14.8","QUARTZ_MICROGRAMS":"145","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-07-17"},{"SOURCE_ROW_NUMBER":"153048","CASSETTE_NO":"58350631","SAMPLE_DT":"06/25/2019","QUARTZ_PCT":"07.2","QUARTZ_MICROGRAMS":"15","OCC_CODE_DESC":"MOTORMAN","SAMPLE_TYPE_DESC":"PART 90 MINER","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-06-25"},{"SOURCE_ROW_NUMBER":"133100","CASSETTE_NO":"58350703","SAMPLE_DT":"06/19/2019","QUARTZ_PCT":"06.3","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-06-19"},{"SOURCE_ROW_NUMBER":"129281","CASSETTE_NO":"58350398","SAMPLE_DT":"06/19/2019","QUARTZ_PCT":"04.7","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-06-19"},{"SOURCE_ROW_NUMBER":"122335","CASSETTE_NO":"58350390","SAMPLE_DT":"06/19/2019","QUARTZ_PCT":"07.3","QUARTZ_MICROGRAMS":"19","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-06-19"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":346,"firstDate":"2017-05-10","lastDate":"2019-09-25","metrics":{"ss":73,"amountDue":212704,"contested":0,"amountPaid":212704,"recentRows":0,"section104d":2,"unterminated":1,"proposedPenalty":276751},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2980215","VIOLATION_NO":"9226538","VIOLATION_ISSUE_DT":"09/25/2019","SIG_SUB":"N","PART_SECTION":"75.605","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/25/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"2980214","VIOLATION_NO":"9226537","VIOLATION_ISSUE_DT":"09/25/2019","SIG_SUB":"Y","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/25/2019","PROPOSED_PENALTY":"3241","AMOUNT_DUE":"1059","AMOUNT_PAID":"1059","CONTESTED_IND":"N","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"2980213","VIOLATION_NO":"9226536","VIOLATION_ISSUE_DT":"09/25/2019","SIG_SUB":"N","PART_SECTION":"75.515","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/25/2019","PROPOSED_PENALTY":"230","AMOUNT_DUE":"230","AMOUNT_PAID":"230","CONTESTED_IND":"N","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"2980212","VIOLATION_NO":"9226535","VIOLATION_ISSUE_DT":"09/25/2019","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/25/2019","PROPOSED_PENALTY":"514","AMOUNT_DUE":"514","AMOUNT_PAID":"514","CONTESTED_IND":"N","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"2980211","VIOLATION_NO":"9226534","VIOLATION_ISSUE_DT":"09/25/2019","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/25/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"2980210","VIOLATION_NO":"9225641","VIOLATION_ISSUE_DT":"09/25/2019","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"10/10/2019","PROPOSED_PENALTY":"2006","AMOUNT_DUE":"655","AMOUNT_PAID":"655","CONTESTED_IND":"N","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"2980209","VIOLATION_NO":"9225640","VIOLATION_ISSUE_DT":"09/25/2019","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/26/2019","PROPOSED_PENALTY":"293","AMOUNT_DUE":"293","AMOUNT_PAID":"293","CONTESTED_IND":"N","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"2980208","VIOLATION_NO":"9225639","VIOLATION_ISSUE_DT":"09/25/2019","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/26/2019","PROPOSED_PENALTY":"270","AMOUNT_DUE":"270","AMOUNT_PAID":"270","CONTESTED_IND":"N","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"2980207","VIOLATION_NO":"9225638","VIOLATION_ISSUE_DT":"09/25/2019","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/26/2019","PROPOSED_PENALTY":"154","AMOUNT_DUE":"154","AMOUNT_PAID":"154","CONTESTED_IND":"N","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"2980206","VIOLATION_NO":"9225637","VIOLATION_ISSUE_DT":"09/25/2019","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/25/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"2980205","VIOLATION_NO":"9225636","VIOLATION_ISSUE_DT":"09/24/2019","SIG_SUB":"N","PART_SECTION":"75.1722(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/25/2019","PROPOSED_PENALTY":"230","AMOUNT_DUE":"230","AMOUNT_PAID":"230","CONTESTED_IND":"N","sourceDate":"2019-09-24"},{"SOURCE_ROW_NUMBER":"2980204","VIOLATION_NO":"9225635","VIOLATION_ISSUE_DT":"09/24/2019","SIG_SUB":"N","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/25/2019","PROPOSED_PENALTY":"440","AMOUNT_DUE":"440","AMOUNT_PAID":"440","CONTESTED_IND":"N","sourceDate":"2019-09-24"}]}],"safety":{"href":"/api/v1/mines/4609528/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609528/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Clamping of trailing cables to equipment.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.605","part":"75","subchapter":"O","subpart":"G","id":"75.605","citation":"30 CFR 75.605","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.515","heading":"Cable fittings; suitability.","id":"75.515","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.515","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nCables shall enter metal frames of motors, splice boxes, and electric compartments only through proper fittings. When insulated wires other than cables pass through metal frames, the holes shall be substantially bushed with insulated bushings.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1722","heading":"Mechanical equipment guards.","id":"75.1722","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1722","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609528","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}