{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4609522","name":"ROAD FORK #52 MINE","status":"Active","status_date":"2020-07-06","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Wyoming","nearest_town":"Pineville","operator_id":"P23835","operator_name":"SPARTAN MINING COMPANY, LLC","controller_id":"0127321","controller_name":"Alpha Metallurgical Resources Inc","district":"C04","office":"Logan WV Field Office","employees":350,"latitude":37.578056,"longitude":-81.57},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":25048},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609522","name":"ROAD FORK #52 MINE"},"operator":{"type":"operator","id":"P23835","name":"SPARTAN MINING COMPANY, LLC"},"controller":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"mine","id":"4609522","name":"ROAD FORK #52 MINE"},"validFrom":"1996-02-05","validTo":"2011-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609522|C02508|1996-02-05|2011-05-31"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"4609522","name":"ROAD FORK #52 MINE"},"validFrom":"2011-06-01","validTo":"2016-07-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609522|0041211|2011-06-01|2016-07-25"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"mine","id":"4609522","name":"ROAD FORK #52 MINE"},"validFrom":"2016-07-26","validTo":"2018-11-08","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609522|0127923|2016-07-26|2018-11-08"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23835","name":"Spartan Mining Company, LLC"},"object":{"type":"mine","id":"4609522","name":"ROAD FORK #52 MINE"},"validFrom":"2016-12-08","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609522|P23835|2016-12-08|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P23835","name":"Spartan Mining Company, LLC"},"validFrom":"2016-12-08","validTo":"2016-07-25","current":false,"derived":true,"evidenceMineId":"4609522","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609522|P23835|2016-12-08|0041211|2011-06-01|2226"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"operator","id":"P23835","name":"Spartan Mining Company, LLC"},"validFrom":"2016-12-08","validTo":"2018-11-08","current":false,"derived":true,"evidenceMineId":"4609522","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609522|P23835|2016-12-08|0127923|2016-07-26|25326"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"P23835","name":"Spartan Mining Company, LLC"},"validFrom":"2016-12-08","validTo":"2011-05-31","current":false,"derived":true,"evidenceMineId":"4609522","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609522|P23835|2016-12-08|C02508|1996-02-05|59447"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"mine","id":"4609522","name":"ROAD FORK #52 MINE"},"validFrom":"2018-11-09","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609522|0127321|2018-11-09|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"operator","id":"P23835","name":"Spartan Mining Company, LLC"},"validFrom":"2018-11-09","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609522","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609522|P23835|2016-12-08|0127321|2018-11-09|24961"}}],"coverage":{"historyRecords":4,"edgeCount":9,"intervalAnomalies":2,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":117,"firstDate":"2017-07-21","lastDate":"2026-09-29","metrics":{"daysLost":2165,"injuries":107,"fatalities":0,"recentRows":108,"restrictedDays":0,"contractorRecords":5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"163211","DOCUMENT_NO":"220262730023","ACCIDENT_DT":"09/29/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","NARRATIVE":"Employee was throwing continuous miner cable out of the roadway, when they inadvertently fell to the mine floor cutting the top of their right middle and ring finger.","sourceDate":"2026-09-29"},{"SOURCE_ROW_NUMBER":"184737","DOCUMENT_NO":"220262590009","ACCIDENT_DT":"09/15/2026","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE has been diagnosed with Occupational Pneumoconiosis.","sourceDate":"2026-09-15"},{"SOURCE_ROW_NUMBER":"124196","DOCUMENT_NO":"220262600004","ACCIDENT_DT":"09/11/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","NARRATIVE":"Employee had finished drilling the hole for the outside primary bolt. As EE began installing the glue, a piece of rock from the roof fell out, striking EE's left shoulder and arm.","sourceDate":"2026-09-11"},{"SOURCE_ROW_NUMBER":"201846","DOCUMENT_NO":"220262580012","ACCIDENT_DT":"09/08/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Supply man, Supply worker, Nipper","NO_INJURIES":"1","NARRATIVE":"While holding the shield covering the compressor in the air, employee states that the shield slipped from their hand, coming down and smashing their left fingers between shield and motor frame.","sourceDate":"2026-09-08"},{"SOURCE_ROW_NUMBER":"77216","DOCUMENT_NO":"220262470028","ACCIDENT_DT":"09/01/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between running or meshing objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","NARRATIVE":"Employee was cleaning out the bottom of the drill pot with their left index finger, when their elbow hit the rotation lever causing the rotation to engage, fouling their finger inside the drill pot.","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"257920","DOCUMENT_NO":"220262530007","ACCIDENT_DT":"08/14/2026","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (PHYSICAL AGENTS)","ACCIDENT_TYPE":"Contact with heat","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","NARRATIVE":"Employee did not incur an occupational injury. EE suffered a non-work-related medical event while standing beside a roof bolter. Employee was treated by EMS paramedic and taken to a local hospital, treated for dehydration and low blood sugar. We are submitting this report to abate citation number 5134629 and this report is to be classified as Degree 8 with (0) lost work days.","sourceDate":"2026-08-14"},{"SOURCE_ROW_NUMBER":"176147","DOCUMENT_NO":"220262230005","ACCIDENT_DT":"08/10/2026","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The miner has been diagnosed with occupational pneumoconiosis.","sourceDate":"2026-08-10"},{"SOURCE_ROW_NUMBER":"120053","DOCUMENT_NO":"220262230007","ACCIDENT_DT":"08/10/2026","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The miner has been diagnosed with occupational pneumoconiosis.","sourceDate":"2026-08-10"},{"SOURCE_ROW_NUMBER":"184736","DOCUMENT_NO":"220262150003","ACCIDENT_DT":"07/28/2026","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The employee has been diagnosed with Occupational Pneumoconiosis.","sourceDate":"2026-07-28"},{"SOURCE_ROW_NUMBER":"270708","DOCUMENT_NO":"220262090011","ACCIDENT_DT":"07/22/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee got out of their shuttle car to assist the electrician working on a roof bolter that was blocking the roadway. As they were cutting the conduit from a panic switch tree, the knife slipped cutting their left forearm.","sourceDate":"2026-07-22"},{"SOURCE_ROW_NUMBER":"4120","DOCUMENT_NO":"220261940013","ACCIDENT_DT":"07/09/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Supply man, Supply worker, Nipper","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was lifting a timber, dropped it, causing it to smash EE's right thumb between a crib and the timber. This resulted in a laceration requiring three sutures.","sourceDate":"2026-07-09"},{"SOURCE_ROW_NUMBER":"163210","DOCUMENT_NO":"220261560005","ACCIDENT_DT":"06/03/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Scoop tram operator, Load/Haul/Dump operator","NO_INJURIES":"1","NARRATIVE":"While on a rail mantrip, following a supply motor going out-by on 1A track, the motor went through a dip on the track and slid backwards striking the rail mantrip.","sourceDate":"2026-06-03"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2020-07-06","lastDate":"2020-07-06","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":2950,"firstDate":"2017-08-22","lastDate":"2026-08-30","metrics":{"ss":574,"delinquent":2688,"recentRows":2842,"paidPenalty":2692134.97,"proposedPenalty":3619930.9,"currentAssessment":2975081},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"3005918","VIOLATION_NO":"5133896","ISSUE_DT":"08/30/2026","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"4749.00","CURRENT_ASSESSMENT_AMT":"4749.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-30"},{"SOURCE_ROW_NUMBER":"3028761","VIOLATION_NO":"5094514","ISSUE_DT":"08/27/2026","CFR_STANDARD_CD":"75.1202","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-27"},{"SOURCE_ROW_NUMBER":"3005939","VIOLATION_NO":"5134614","ISSUE_DT":"08/27/2026","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"592.00","CURRENT_ASSESSMENT_AMT":"592.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-27"},{"SOURCE_ROW_NUMBER":"3005938","VIOLATION_NO":"5134613","ISSUE_DT":"08/27/2026","CFR_STANDARD_CD":"75.604(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"8315.00","CURRENT_ASSESSMENT_AMT":"8315.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-27"},{"SOURCE_ROW_NUMBER":"3005937","VIOLATION_NO":"5134612","ISSUE_DT":"08/26/2026","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"959.00","CURRENT_ASSESSMENT_AMT":"959.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"3005867","VIOLATION_NO":"5096688","ISSUE_DT":"08/26/2026","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"6194.00","CURRENT_ASSESSMENT_AMT":"6194.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"3005936","VIOLATION_NO":"5134611","ISSUE_DT":"08/25/2026","CFR_STANDARD_CD":"77.1607(cc)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"226.00","CURRENT_ASSESSMENT_AMT":"226.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-25"},{"SOURCE_ROW_NUMBER":"3005935","VIOLATION_NO":"5134610","ISSUE_DT":"08/25/2026","CFR_STANDARD_CD":"77.205(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-25"},{"SOURCE_ROW_NUMBER":"3005934","VIOLATION_NO":"5134609","ISSUE_DT":"08/25/2026","CFR_STANDARD_CD":"75.360(g)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1037.00","CURRENT_ASSESSMENT_AMT":"1037.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-25"},{"SOURCE_ROW_NUMBER":"3028760","VIOLATION_NO":"5094513","ISSUE_DT":"08/24/2026","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2312.00","CURRENT_ASSESSMENT_AMT":"2312.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-24"},{"SOURCE_ROW_NUMBER":"3005933","VIOLATION_NO":"5134608","ISSUE_DT":"08/20/2026","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"336.00","CURRENT_ASSESSMENT_AMT":"336.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-20"},{"SOURCE_ROW_NUMBER":"3005932","VIOLATION_NO":"5134607","ISSUE_DT":"08/20/2026","CFR_STANDARD_CD":"75.1403-10(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"226.00","CURRENT_ASSESSMENT_AMT":"226.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-20"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":456,"firstDate":"2022-03-08","lastDate":"2026-10-02","metrics":{"appeals":0,"decisions":420,"recentRows":420,"decisionPenalty":1055611,"originalPenalty":1711590.1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"465423","VIOLATION_NO":"5095173","DOCKET_NO":"WEVA 2026-0368","DECISION_DT":"10/02/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1550.00","DECISION_PENALTY_AMT":"1550.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-10-02"},{"SOURCE_ROW_NUMBER":"465422","VIOLATION_NO":"5092946","DOCKET_NO":"WEVA 2026-0368","DECISION_DT":"10/02/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"11450.00","DECISION_PENALTY_AMT":"5150.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-10-02"},{"SOURCE_ROW_NUMBER":"464266","VIOLATION_NO":"5096622","DOCKET_NO":"WEVA 2026-0368","DECISION_DT":"10/02/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"8315.00","DECISION_PENALTY_AMT":"3815.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-10-02"},{"SOURCE_ROW_NUMBER":"464265","VIOLATION_NO":"5096620","DOCKET_NO":"WEVA 2026-0368","DECISION_DT":"10/02/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"5574.00","DECISION_PENALTY_AMT":"5574.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-10-02"},{"SOURCE_ROW_NUMBER":"464184","VIOLATION_NO":"5133235","DOCKET_NO":"WEVA 2026-0368","DECISION_DT":"10/02/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"6037.00","DECISION_PENALTY_AMT":"2737.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-10-02"},{"SOURCE_ROW_NUMBER":"463917","VIOLATION_NO":"5133249","DOCKET_NO":"WEVA 2026-0368","DECISION_DT":"10/02/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3736.00","DECISION_PENALTY_AMT":"3736.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-10-02"},{"SOURCE_ROW_NUMBER":"170203","VIOLATION_NO":"9847596","DOCKET_NO":"WEVA 2026-0368","DECISION_DT":"10/02/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"8315.00","DECISION_PENALTY_AMT":"3815.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-10-02"},{"SOURCE_ROW_NUMBER":"169775","VIOLATION_NO":"5133250","DOCKET_NO":"WEVA 2026-0368","DECISION_DT":"10/02/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2936.00","DECISION_PENALTY_AMT":"2936.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-10-02"},{"SOURCE_ROW_NUMBER":"169774","VIOLATION_NO":"5096609","DOCKET_NO":"WEVA 2026-0368","DECISION_DT":"10/02/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3736.00","DECISION_PENALTY_AMT":"3736.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-10-02"},{"SOURCE_ROW_NUMBER":"465006","VIOLATION_NO":"5186317","DOCKET_NO":"WEVA 2026-0316","DECISION_DT":"08/10/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4383.00","DECISION_PENALTY_AMT":"4383.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-08-10"},{"SOURCE_ROW_NUMBER":"464470","VIOLATION_NO":"5096586","DOCKET_NO":"WEVA 2026-0316","DECISION_DT":"08/10/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"9757.00","DECISION_PENALTY_AMT":"4383.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-08-10"},{"SOURCE_ROW_NUMBER":"463453","VIOLATION_NO":"5096603","DOCKET_NO":"WEVA 2026-0316","DECISION_DT":"08/10/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2503.00","DECISION_PENALTY_AMT":"151.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-08-10"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":15044,"firstDate":"2017-08-09","lastDate":"2026-10-08","metrics":{"recentRows":14203,"cpdmSamples":13540,"voidSamples":2853,"validSamples":12191,"maxConcentration":96.617,"concentrationTotal":7955.633},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"3028849","SMP_TAKEN_DT":"10/8/2026","CONC":".252","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2943778","SMP_TAKEN_DT":"10/8/2026","CONC":".299","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2773409","SMP_TAKEN_DT":"10/8/2026","CONC":".445","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2517282","SMP_TAKEN_DT":"10/8/2026","CONC":".276","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2432072","SMP_TAKEN_DT":"10/8/2026","CONC":".542","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"1921066","SMP_TAKEN_DT":"10/8/2026","CONC":".382","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"1836119","SMP_TAKEN_DT":"10/8/2026","CONC":".29","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"1836117","SMP_TAKEN_DT":"10/8/2026","CONC":".244","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"3029283","SMP_TAKEN_DT":"10/7/2026","CONC":".249","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"3028956","SMP_TAKEN_DT":"10/7/2026","CONC":".207","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2859384","SMP_TAKEN_DT":"10/7/2026","CONC":".304","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2773485","SMP_TAKEN_DT":"10/7/2026","CONC":".13","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":189,"firstDate":"2020-06-24","lastDate":"2026-10-05","metrics":{"linkedIssuances":189},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":455,"firstDate":"2021-08-03","lastDate":"2026-07-31","metrics":{"decisions":419,"ssChanged":95,"recentRows":455,"decisionPenalty":1045611,"proposedPenalty":1808962},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"110465","CITATION_NO":"5096677","CITATION_ISSUE_DT":"07/31/2026","DOCKET_NO":"WEVA 2026-0406","CFR_STANDARD_CODE":"75.333(c)(3)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"504.00","sourceDate":"2026-07-31"},{"SOURCE_ROW_NUMBER":"451774","CITATION_NO":"5091825","CITATION_ISSUE_DT":"07/30/2026","DOCKET_NO":"WEVA 2026-0406","CFR_STANDARD_CODE":"77.1606(c)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"336.00","sourceDate":"2026-07-30"},{"SOURCE_ROW_NUMBER":"393629","CITATION_NO":"5133864","CITATION_ISSUE_DT":"07/30/2026","DOCKET_NO":"WEVA 2026-0406","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1037.00","sourceDate":"2026-07-30"},{"SOURCE_ROW_NUMBER":"336688","CITATION_NO":"5134208","CITATION_ISSUE_DT":"07/30/2026","DOCKET_NO":"WEVA 2026-0406","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"6194.00","sourceDate":"2026-07-30"},{"SOURCE_ROW_NUMBER":"336572","CITATION_NO":"5134210","CITATION_ISSUE_DT":"07/30/2026","DOCKET_NO":"WEVA 2026-0406","CFR_STANDARD_CODE":"75.1725(a)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"465.00","sourceDate":"2026-07-30"},{"SOURCE_ROW_NUMBER":"280176","CITATION_NO":"5133866","CITATION_ISSUE_DT":"07/30/2026","DOCKET_NO":"WEVA 2026-0406","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"504.00","sourceDate":"2026-07-30"},{"SOURCE_ROW_NUMBER":"280088","CITATION_NO":"5091826","CITATION_ISSUE_DT":"07/30/2026","DOCKET_NO":"WEVA 2026-0406","CFR_STANDARD_CODE":"77.208(e)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"336.00","sourceDate":"2026-07-30"},{"SOURCE_ROW_NUMBER":"223401","CITATION_NO":"5095571","CITATION_ISSUE_DT":"07/30/2026","DOCKET_NO":"WEVA 2026-0406","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1467.00","sourceDate":"2026-07-30"},{"SOURCE_ROW_NUMBER":"166910","CITATION_NO":"5133865","CITATION_ISSUE_DT":"07/30/2026","DOCKET_NO":"WEVA 2026-0406","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2503.00","sourceDate":"2026-07-30"},{"SOURCE_ROW_NUMBER":"166746","CITATION_NO":"5091823","CITATION_ISSUE_DT":"07/30/2026","DOCKET_NO":"WEVA 2026-0406","CFR_STANDARD_CODE":"77.1606(c)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"336.00","sourceDate":"2026-07-30"},{"SOURCE_ROW_NUMBER":"110670","CITATION_NO":"5095947","CITATION_ISSUE_DT":"07/30/2026","DOCKET_NO":"WEVA 2026-0406","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1431.00","sourceDate":"2026-07-30"},{"SOURCE_ROW_NUMBER":"110414","CITATION_NO":"5095952","CITATION_ISSUE_DT":"07/30/2026","DOCKET_NO":"WEVA 2026-0406","CFR_STANDARD_CODE":"75.1719-4(b)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"504.00","sourceDate":"2026-07-30"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":792,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":172,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":4,"firstDate":"2016-12-08","lastDate":"2016-12-08","metrics":{"recentRows":0,"currentOperatorTenures":4,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":601,"firstDate":"2017-02-24","lastDate":"2026-10-06","metrics":{"inspectors":1078,"recentRows":546,"onSiteHours":15169.75,"inspectionHours":19886.25,"inspectionSamples":72},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1087365","EVENT_NO":"F02EE11","INSPECTION_BEGIN_DT":"10/06/2026","INSPECTION_END_DT":"10/06/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"0","SUM_TOTAL_INSP_HOURS":"0","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"624000","EVENT_NO":"F025C04","INSPECTION_BEGIN_DT":"10/01/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"0","SUM_TOTAL_INSP_HOURS":"0","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"29549","EVENT_NO":"F02EE10","INSPECTION_BEGIN_DT":"10/01/2026","INSPECTION_END_DT":"10/01/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"6.75","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"825734","EVENT_NO":"F036050","INSPECTION_BEGIN_DT":"09/29/2026","INSPECTION_END_DT":"09/29/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2026-09-29"},{"SOURCE_ROW_NUMBER":"551652","EVENT_NO":"F0402EC","INSPECTION_BEGIN_DT":"09/24/2026","INSPECTION_END_DT":"09/24/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"21","SUM_TOTAL_ON_SITE_HOURS":"14.5","sourceDate":"2026-09-24"},{"SOURCE_ROW_NUMBER":"681799","EVENT_NO":"F03604F","INSPECTION_BEGIN_DT":"09/23/2026","INSPECTION_END_DT":"09/23/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.5","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-09-23"},{"SOURCE_ROW_NUMBER":"1144344","EVENT_NO":"F03604E","INSPECTION_BEGIN_DT":"09/16/2026","INSPECTION_END_DT":"09/16/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2026-09-16"},{"SOURCE_ROW_NUMBER":"1155322","EVENT_NO":"F025C03","INSPECTION_BEGIN_DT":"09/15/2026","INSPECTION_END_DT":"09/15/2026","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.25","SUM_TOTAL_ON_SITE_HOURS":"8.5","sourceDate":"2026-09-15"},{"SOURCE_ROW_NUMBER":"553544","EVENT_NO":"F03604D","INSPECTION_BEGIN_DT":"09/11/2026","INSPECTION_END_DT":"09/11/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2026-09-11"},{"SOURCE_ROW_NUMBER":"976460","EVENT_NO":"F03604C","INSPECTION_BEGIN_DT":"09/09/2026","INSPECTION_END_DT":"09/09/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2026-09-09"},{"SOURCE_ROW_NUMBER":"80444","EVENT_NO":"F03604B","INSPECTION_BEGIN_DT":"09/04/2026","INSPECTION_END_DT":"09/04/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2026-09-04"},{"SOURCE_ROW_NUMBER":"409158","EVENT_NO":"F0307C0","INSPECTION_BEGIN_DT":"08/28/2026","INSPECTION_END_DT":"08/28/2026","ACTIVITY_CODE":"E03","ACTIVITY":"103 (g) Written Notification Hazard Complaint Inspectio","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-08-28"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":86,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2026-Q2":{"hours":211660,"employees":341,"production":511529},"2026-Q1":{"hours":230496,"employees":347,"production":457918},"2025-Q4":{"hours":197345,"employees":341,"production":402754},"2025-Q3":{"hours":210129,"employees":344,"production":435782},"2025-Q2":{"hours":211865,"employees":344,"production":428925},"2025-Q1":{"hours":216059,"employees":344,"production":422500},"2024-Q4":{"hours":194551,"employees":341,"production":419451},"2024-Q3":{"hours":200046,"employees":336,"production":366872},"2024-Q2":{"hours":203953,"employees":326,"production":485375},"2024-Q1":{"hours":203756,"employees":316,"production":501027},"2023-Q4":{"hours":184424,"employees":321,"production":470621},"2023-Q3":{"hours":182955,"employees":306,"production":475320}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":16,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2019":{"hours":56077,"employees":23,"production":0},"2020":{"hours":242006,"employees":112,"production":366026},"2021":{"hours":526319,"employees":218,"production":1471247},"2022":{"hours":681140,"employees":278,"production":1813483},"2023":{"hours":749097,"employees":307,"production":1963202},"2024":{"hours":802306,"employees":330,"production":1772725},"2025":{"hours":835398,"employees":343,"production":1689961},"2026":{"hours":442156,"employees":345,"production":969447}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":358,"firstDate":"2017-12-18","lastDate":"2026-08-26","metrics":{"recentRows":293,"doseOver100":70,"actDoseTotal":26016,"pelDoseTotal":20210},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"269201","EVENT_NO":"F025BEC","SURVEY_DATE":"08/26/2026","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"102","PEL_DOSE_90":"91","SURVEY_TYPE":"I","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"269200","EVENT_NO":"F025BEC","SURVEY_DATE":"08/26/2026","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"22","PEL_DOSE_90":"38","SURVEY_TYPE":"I","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"269199","EVENT_NO":"F025BEC","SURVEY_DATE":"08/26/2026","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"89","PEL_DOSE_90":"73","SURVEY_TYPE":"I","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"269198","EVENT_NO":"F025BEC","SURVEY_DATE":"08/26/2026","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","ACT_DOSE_85":"53","PEL_DOSE_90":"39","SURVEY_TYPE":"I","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"269197","EVENT_NO":"F025BEC","SURVEY_DATE":"08/26/2026","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"90","PEL_DOSE_90":"67","SURVEY_TYPE":"I","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"269196","EVENT_NO":"F025BEC","SURVEY_DATE":"08/26/2026","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"128","PEL_DOSE_90":"98","SURVEY_TYPE":"I","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"269183","EVENT_NO":"F011550","SURVEY_DATE":"08/10/2026","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","ACT_DOSE_85":"45","PEL_DOSE_90":"67","SURVEY_TYPE":"I","sourceDate":"2026-08-10"},{"SOURCE_ROW_NUMBER":"269182","EVENT_NO":"F011550","SURVEY_DATE":"08/10/2026","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"110","PEL_DOSE_90":"127","SURVEY_TYPE":"I","sourceDate":"2026-08-10"},{"SOURCE_ROW_NUMBER":"269181","EVENT_NO":"F011550","SURVEY_DATE":"08/10/2026","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"86","PEL_DOSE_90":"124","SURVEY_TYPE":"I","sourceDate":"2026-08-10"},{"SOURCE_ROW_NUMBER":"269180","EVENT_NO":"F011550","SURVEY_DATE":"08/10/2026","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"173","PEL_DOSE_90":"190","SURVEY_TYPE":"I","sourceDate":"2026-08-10"},{"SOURCE_ROW_NUMBER":"269179","EVENT_NO":"F011550","SURVEY_DATE":"08/10/2026","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"118","PEL_DOSE_90":"127","SURVEY_TYPE":"I","sourceDate":"2026-08-10"},{"SOURCE_ROW_NUMBER":"269178","EVENT_NO":"F011550","SURVEY_DATE":"08/10/2026","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"126","PEL_DOSE_90":"108","SURVEY_TYPE":"I","sourceDate":"2026-08-10"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":738,"firstDate":"2017-08-09","lastDate":"2026-08-26","metrics":{"recentRows":695,"voidSamples":18,"maxQuartzPct":32.8,"validSamples":720,"quartzPctTotal":3322.7},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"165385","CASSETTE_NO":"58595916","SAMPLE_DT":"08/26/2026","QUARTZ_PCT":"05.9","QUARTZ_MICROGRAMS":"13","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"157312","CASSETTE_NO":"58595954","SAMPLE_DT":"08/26/2026","QUARTZ_PCT":"02.5","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"156029","CASSETTE_NO":"58596129","SAMPLE_DT":"08/26/2026","QUARTZ_PCT":"03.9","QUARTZ_MICROGRAMS":"12","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"154981","CASSETTE_NO":"58596128","SAMPLE_DT":"08/26/2026","QUARTZ_PCT":"02.1","QUARTZ_MICROGRAMS":"5","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"136323","CASSETTE_NO":"58595873","SAMPLE_DT":"08/26/2026","QUARTZ_PCT":"00.7","QUARTZ_MICROGRAMS":"1","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"123896","CASSETTE_NO":"58595956","SAMPLE_DT":"08/26/2026","QUARTZ_PCT":"11.6","QUARTZ_MICROGRAMS":"25","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"113681","CASSETTE_NO":"58595731","SAMPLE_DT":"08/26/2026","QUARTZ_PCT":"03.2","QUARTZ_MICROGRAMS":"5","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"105050","CASSETTE_NO":"58595693","SAMPLE_DT":"08/26/2026","QUARTZ_PCT":"01.2","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"96272","CASSETTE_NO":"58595918","SAMPLE_DT":"08/26/2026","QUARTZ_PCT":"02.8","QUARTZ_MICROGRAMS":"12","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"95906","CASSETTE_NO":"58595685","SAMPLE_DT":"08/26/2026","QUARTZ_PCT":"01.0","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"92829","CASSETTE_NO":"58595705","SAMPLE_DT":"08/26/2026","QUARTZ_PCT":"01.6","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"92097","CASSETTE_NO":"58595959","SAMPLE_DT":"08/26/2026","QUARTZ_PCT":"01.9","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-26"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":3068,"firstDate":"2017-08-22","lastDate":"2026-10-08","metrics":{"ss":588,"amountDue":2975081,"contested":0,"amountPaid":2692134.97,"recentRows":2959,"section104d":3,"unterminated":6,"proposedPenalty":3619930.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2979086","VIOLATION_NO":"5134654","VIOLATION_ISSUE_DT":"10/08/2026","SIG_SUB":"N","PART_SECTION":"50.20-6","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"HighNegligence","CONTESTED_IND":"N","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2979085","VIOLATION_NO":"5134653","VIOLATION_ISSUE_DT":"10/08/2026","SIG_SUB":"N","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/08/2026","CONTESTED_IND":"N","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2979084","VIOLATION_NO":"5134652","VIOLATION_ISSUE_DT":"10/08/2026","SIG_SUB":"N","PART_SECTION":"75.360(g)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","CONTESTED_IND":"N","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2979083","VIOLATION_NO":"5134651","VIOLATION_ISSUE_DT":"10/07/2026","SIG_SUB":"N","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/07/2026","CONTESTED_IND":"N","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2979082","VIOLATION_NO":"5134650","VIOLATION_ISSUE_DT":"10/07/2026","SIG_SUB":"N","PART_SECTION":"75.605","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/07/2026","CONTESTED_IND":"N","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2979081","VIOLATION_NO":"5134649","VIOLATION_ISSUE_DT":"10/07/2026","SIG_SUB":"N","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/08/2026","CONTESTED_IND":"N","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2979080","VIOLATION_NO":"5134648","VIOLATION_ISSUE_DT":"10/07/2026","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/07/2026","CONTESTED_IND":"N","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2979074","VIOLATION_NO":"5094896","VIOLATION_ISSUE_DT":"10/07/2026","SIG_SUB":"Y","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/07/2026","CONTESTED_IND":"N","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2979073","VIOLATION_NO":"5094895","VIOLATION_ISSUE_DT":"10/07/2026","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/07/2026","CONTESTED_IND":"N","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2979072","VIOLATION_NO":"5094894","VIOLATION_ISSUE_DT":"10/07/2026","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/07/2026","CONTESTED_IND":"N","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2979278","VIOLATION_NO":"5131424","VIOLATION_ISSUE_DT":"10/06/2026","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2979096","VIOLATION_NO":"5135050","VIOLATION_ISSUE_DT":"10/06/2026","SIG_SUB":"N","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","CONTESTED_IND":"N","sourceDate":"2026-10-06"}]}],"safety":{"href":"/api/v1/mines/4609522/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609522/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":{"averageEmployees":330,"companyType":"Operating Subsidiary","components":[{"averageEmployees":330,"laborHours":802306,"mineType":"Underground","productionTons":1772725}],"county":"Wyoming","laborHours":802306,"mineName":"Road Fork #52 Mine","mineType":"Underground","mshaId":"4609522","operatingAddress":"P.O. Box 460, Brenton, WV 24818","operatingCompany":"Spartan Mining Company, Llc","operationType":"Mine only","productionTons":1772725,"reportedRows":1,"sourceUrl":"https://www.eia.gov/coal/data/public/xls/coalpublic2024.xlsx","state":"West Virginia (Southern)","status":"Active","supplyRegion":"Appalachia Central","union":"","year":2024},"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Criteria—MSHA Form 7000-1, Section C.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-I/part-50/subpart-C/section-50.20-6","part":"50","subchapter":"I","subpart":"C","id":"50.20-6","citation":"30 CFR 50.20-6","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER I—ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND PRODUCTION IN MINES","partHeading":"PART 50—NOTIFICATION, INVESTIGATION, REPORTS AND RECORDS OF ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND COAL PRODUCTION IN MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.360","heading":"Preshift examination at fixed intervals.","id":"75.360","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.360","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) Except as provided in paragraph (a)(2) of this section, a certified person designated by the operator must make a preshift examination within 3 hours preceding the beginning of any 8-hour interval during which any person is scheduled to work or travel underground. No person other than certified examiners may enter or remain in any underground area unless a preshift examination has been completed for the established 8-hour interval. The operator must establish 8-hour intervals of time subject to the required preshift examinations.\n\n(2) Preshift examinations of areas where pumpers are scheduled to work or travel shall not be required prior to the pumper entering the areas if the pumper is a certified person and the pumper conducts an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, tests for methane and oxygen deficiency, and determines if the air is moving in its proper direction in the area where the pumper works or travels. The examination of the area must be completed before the pumper performs any other work. A record of all hazardous conditions and violations of the mandatory health or safety standards found by the pumper shall be made and retained in accordance with § 75.363 of this part.\n\n(b) The person conducting the preshift examination shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction at the following locations:\n\n(1) Roadways, travelways and track haulageways where persons are scheduled, prior to the beginning of the preshift examination, to work or travel during the oncoming shift.\n\n(2) Belt conveyors that will be used to transport persons during the oncoming shift and the entries in which these belt conveyors are located.\n\n(3) Working sections and areas where mechanized mining equipment is being installed or removed, if anyone is scheduled to work on the section or in the area during the oncoming shift. The scope of the examination shall include the working places, approaches to worked-out areas and ventilation controls on these sections and in these areas, and the examination shall include tests of the roof, face and rib conditions on these sections and in these areas.\n\n(4) Approaches to worked-out areas along intake air courses and at the entries used to carry air into worked-out areas if the intake air passing the approaches is used to ventilate working sections where anyone is scheduled to work during the oncoming shift. The examination of the approaches to the worked-out areas shall be made in the intake air course immediately inby and outby each entry used to carry air into the worked-out area. An examination of the entries used to carry air into the worked-out areas shall be conducted at a point immediately inby the intersection of each entry with the intake air course.\n\n(5) Seals along intake air courses where intake air passes by a seal to ventilate working sections where anyone is scheduled to work during the oncoming shift.\n\n(6)(i) Entries and rooms developed after November 15, 1992, and developed more than 2 crosscuts off an intake air course without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift; and,\n\n(ii) Entries and rooms developed after November 15, 1992, and driven more than 20 feet off an intake air course without a crosscut and without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift.\n\n(7) Areas where trolley wires or trolley feeder wires are to be or will remain energized during the oncoming shift.\n\n(8) High spots along intake air courses where methane is likely to accumulate, if equipment will be operated in the area during the shift.\n\n(9) Underground electrical installations referred to in § 75.340(a), except those pumps listed in § 75.340 (b)(2) through (b)(6), and areas where compressors subject to § 75.344 are installed if the electrical installation or compressor is or will be energized during the shift.\n\n(10) Other areas where work or travel during the oncoming shift is scheduled prior to the beginning of the preshift examination.\n\n(11) Preshift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) The person conducting the preshift examination shall determine the volume of air entering each of the following areas if anyone is scheduled to work in the areas during the oncoming shift:\n\n(1) In the last open crosscut of each set of entries or rooms on each working section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) On each longwall or shortwall in the intake entry or entries at the intake end of the longwall or shortwall face immediately outby the face and the velocity of air at each end of the face at the locations specified in the approved ventilation plan.\n\n(3) At the intake end of any pillar line—\n\n(i) If a single split of air is used, in the intake entry furthest from the return air course, immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) If a split system is used, in the intake entries of each split immediately inby the split point.\n\n(d) The person conducting the preshift examination shall check the refuge alternative for damage, the integrity of the tamper-evident seal and the mechanisms required to deploy the refuge alternative, and the ready availability of compressed oxygen and air.\n\n(e) The district manager may require the operator to examine other areas of the mine or examine for other hazards and violations of other mandatory health or safety standards found during the preshift examination.\n\n(f) Certification. At each working place examined, the person doing the preshift examination shall certify by initials, date, and the time, that the examination was made. In areas required to be examined outby a working section, the certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(g) Recordkeeping. A record of the results of each preshift examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards and their locations found by the examiner during each examination, and of the results and locations of air and methane measurements, shall be made on the surface before any persons, other than certified persons conducting examinations required by this subpart, enter any underground area of the mine. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the certified person who made the examination or by a person designated by the operator. If the record is made by someone other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. A record shall also be made by a certified person of the action taken to correct hazardous conditions and violations of mandatory health or safety standards found during the preshift examination. All preshift and corrective action records shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(h) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 62 FR 35085, June 30, 1997; 64 FR 45170, Aug. 19, 1999; 73 FR 80697, Dec. 31, 2008; 77 FR 20714, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":2},{"chapter":"I","heading":"Clamping of trailing cables to equipment.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.605","part":"75","subchapter":"O","subpart":"G","id":"75.605","citation":"30 CFR 75.605","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609522","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}