{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4609495","name":"Eagle Seam Deep Mine","status":"NonProducing","status_date":"2024-06-03","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Logan","nearest_town":"Verner","operator_id":"0122932","operator_name":"Ramaco Resources, LLC","controller_id":"0137341","controller_name":"Ramaco Resources Inc","district":"C04","office":"Logan WV Field Office","employees":8,"latitude":37.748333,"longitude":-81.710556},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":8863},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609495","name":"Eagle Seam Deep Mine"},"operator":{"type":"operator","id":"0122932","name":"Ramaco Resources, LLC"},"controller":{"type":"controller","id":"0137341","name":"Ramaco Resources Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"0104377","name":"Michael D Bauersachs"},"object":{"type":"mine","id":"4609495","name":"Eagle Seam Deep Mine"},"validFrom":"2012-04-27","validTo":"2016-12-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609495|0104377|2012-04-27|2016-12-31"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0122932","name":"Ramaco Resources, LLC"},"object":{"type":"mine","id":"4609495","name":"Eagle Seam Deep Mine"},"validFrom":"2014-07-31","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609495|0122932|2014-07-31|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0104377","name":"Michael D Bauersachs"},"object":{"type":"operator","id":"0122932","name":"Ramaco Resources, LLC"},"validFrom":"2014-07-31","validTo":"2016-12-31","current":false,"derived":true,"evidenceMineId":"4609495","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609495|0122932|2014-07-31|0104377|2012-04-27|18192"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0137341","name":"Ramaco Resources Inc"},"object":{"type":"mine","id":"4609495","name":"Eagle Seam Deep Mine"},"validFrom":"2017-01-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609495|0137341|2017-01-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0137341","name":"Ramaco Resources Inc"},"object":{"type":"operator","id":"0122932","name":"Ramaco Resources, LLC"},"validFrom":"2017-01-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609495","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609495|0122932|2014-07-31|0137341|2017-01-01|27753"}}],"coverage":{"historyRecords":2,"edgeCount":5,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":50,"firstDate":"2017-10-09","lastDate":"2025-03-18","metrics":{"daysLost":3261,"injuries":32,"fatalities":0,"recentRows":20,"restrictedDays":0,"contractorRecords":8},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"111376","DOCUMENT_NO":"220250780026","ACCIDENT_DT":"03/18/2025","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"153","NARRATIVE":"Employee was washing the head drive area and fell. They tried to catch themselves and fell on their wrist","sourceDate":"2025-03-18"},{"SOURCE_ROW_NUMBER":"115702","DOCUMENT_NO":"220250290049","ACCIDENT_DT":"01/24/2025","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","NARRATIVE":"Employee was unloading supplies from the scoop bucket and placing them onto the roof bolter.  When the employee was picking up some bolts, the bolting machine moved, and employee jumped into the scoop bucket to get out of the way and accidentally got their foot caught between the scoop bucket and the roof bolter.","sourceDate":"2025-01-24"},{"SOURCE_ROW_NUMBER":"244991","DOCUMENT_NO":"220242710011","ACCIDENT_DT":"09/19/2024","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"An unplanned roof fall occurred above anchorage in the No. 7 entry outby spad 3313 measuring approx. 60 foot long and approx. 35 inches to 45 inches thick.","sourceDate":"2024-09-19"},{"SOURCE_ROW_NUMBER":"180447","DOCUMENT_NO":"220242080030","ACCIDENT_DT":"07/20/2024","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was performing maintenance on a shuttle car, when a piece of draw rock 11 inches long, 6 inches wide and up to 3/4 inch thick fell and struck EE's left hand causing a laceration.  Gloves were worn at time of incident.","sourceDate":"2024-07-20"},{"SOURCE_ROW_NUMBER":"150380","DOCUMENT_NO":"220241660010","ACCIDENT_DT":"06/11/2024","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Scoop car/Scooptram operator, Load/Haul/Dump (LHD) operator, Teletram operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE was letting down cable out of a rope hanger that was connected to a spad nail. The spad nail came out of the rib, hitting EE's left hand against a roof plate cutting EE's hand","sourceDate":"2024-06-11"},{"SOURCE_ROW_NUMBER":"124194","DOCUMENT_NO":"220241310002","ACCIDENT_DT":"04/29/2024","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"EXPLODING VESSELS UNDER PRESSURE","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was removing a bull line for a pressure pump, the line still had some residual pressure after shutting off the in line valve.  As the employee uncoupled the line it blew off and struck the employee in the forehead causing a laceration.","sourceDate":"2024-04-29"},{"SOURCE_ROW_NUMBER":"12715","DOCUMENT_NO":"220240730011","ACCIDENT_DT":"03/06/2024","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was pulling on a piece of conveyor belt, when the channel lock pliers employee was using slipped striking employee in the face.","sourceDate":"2024-03-06"},{"SOURCE_ROW_NUMBER":"262276","DOCUMENT_NO":"220232510002","ACCIDENT_DT":"08/29/2023","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"55","NARRATIVE":"Employee was struck on the left knee by a rock while roof bolting.","sourceDate":"2023-08-29"},{"SOURCE_ROW_NUMBER":"16926","DOCUMENT_NO":"220230410003","ACCIDENT_DT":"01/31/2023","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was tramming roof bolter and a stack of roof bolt plates slid off the deck and came in contact with EE's hand causing injury.","sourceDate":"2023-01-31"},{"SOURCE_ROW_NUMBER":"253579","DOCUMENT_NO":"220222370021","ACCIDENT_DT":"08/16/2022","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"37","NARRATIVE":"Employee was struck in the face with a crib block.","sourceDate":"2022-08-16"},{"SOURCE_ROW_NUMBER":"206213","DOCUMENT_NO":"220220410005","ACCIDENT_DT":"01/31/2022","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall from ladders","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"110","NARRATIVE":"Employee was using a ladder to build a stopping.  EE was carrying block up the ladder and the ladder shifted causing EE to jump and then fall causing injury to EE's shoulder and right side.","sourceDate":"2022-01-31"},{"SOURCE_ROW_NUMBER":"120046","DOCUMENT_NO":"220213120024","ACCIDENT_DT":"10/27/2021","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"70","NARRATIVE":"While assisting pulling belt, a miner was struck above the right eye by a shive rope when it broke. Injury was not the result of a training or compliance issue.","sourceDate":"2021-10-27"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2024-06-03","lastDate":"2024-06-03","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":956,"firstDate":"2016-11-08","lastDate":"2026-08-03","metrics":{"ss":170,"delinquent":930,"recentRows":632,"paidPenalty":634233,"proposedPenalty":916321.9,"currentAssessment":665840},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2943044","VIOLATION_NO":"5098910","ISSUE_DT":"08/03/2026","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"165.00","CURRENT_ASSESSMENT_AMT":"165.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-03"},{"SOURCE_ROW_NUMBER":"2943043","VIOLATION_NO":"5098909","ISSUE_DT":"08/03/2026","CFR_STANDARD_CD":"77.207","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"165.00","CURRENT_ASSESSMENT_AMT":"165.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-03"},{"SOURCE_ROW_NUMBER":"2891940","VIOLATION_NO":"5099719","ISSUE_DT":"04/15/2026","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"165.00","CURRENT_ASSESSMENT_AMT":"165.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-04-15"},{"SOURCE_ROW_NUMBER":"2891939","VIOLATION_NO":"5099718","ISSUE_DT":"04/08/2026","CFR_STANDARD_CD":"75.1731(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"165.00","CURRENT_ASSESSMENT_AMT":"165.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-04-08"},{"SOURCE_ROW_NUMBER":"2949831","VIOLATION_NO":"5132513","ISSUE_DT":"03/09/2026","CFR_STANDARD_CD":"75.818(b)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"288.00","CURRENT_ASSESSMENT_AMT":"288.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-03-09"},{"SOURCE_ROW_NUMBER":"2949830","VIOLATION_NO":"5132512","ISSUE_DT":"03/05/2026","CFR_STANDARD_CD":"75.1101-10","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-03-05"},{"SOURCE_ROW_NUMBER":"2949829","VIOLATION_NO":"5132511","ISSUE_DT":"03/05/2026","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"177.00","CURRENT_ASSESSMENT_AMT":"177.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-03-05"},{"SOURCE_ROW_NUMBER":"2949828","VIOLATION_NO":"5132510","ISSUE_DT":"03/05/2026","CFR_STANDARD_CD":"77.512","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1431.00","CURRENT_ASSESSMENT_AMT":"1431.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-03-05"},{"SOURCE_ROW_NUMBER":"2949827","VIOLATION_NO":"5132509","ISSUE_DT":"03/05/2026","CFR_STANDARD_CD":"77.205(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"193.00","CURRENT_ASSESSMENT_AMT":"193.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-03-05"},{"SOURCE_ROW_NUMBER":"2891918","VIOLATION_NO":"9835599","ISSUE_DT":"11/20/2025","CFR_STANDARD_CD":"75.518","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2025-11-20"},{"SOURCE_ROW_NUMBER":"2891917","VIOLATION_NO":"5099700","ISSUE_DT":"11/20/2025","CFR_STANDARD_CD":"75.1731(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"267.00","CURRENT_ASSESSMENT_AMT":"267.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2025-11-20"},{"SOURCE_ROW_NUMBER":"2931918","VIOLATION_NO":"9837171","ISSUE_DT":"08/19/2025","CFR_STANDARD_CD":"75.1103-5(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1320.00","CURRENT_ASSESSMENT_AMT":"1320.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2025-08-19"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":273,"firstDate":"2018-05-18","lastDate":"2026-10-01","metrics":{"appeals":0,"decisions":273,"recentRows":180,"decisionPenalty":292453,"originalPenalty":545560.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"432916","VIOLATION_NO":"9562679","DOCKET_NO":"WEVA 2022-0260","DECISION_DT":"10/01/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"987.00","DECISION_PENALTY_AMT":"987.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Young","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"432653","VIOLATION_NO":"9562663","DOCKET_NO":"WEVA 2022-0260","DECISION_DT":"10/01/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2194.00","DECISION_PENALTY_AMT":"661.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Young","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"150332","VIOLATION_NO":"9562665","DOCKET_NO":"WEVA 2022-0260","DECISION_DT":"10/01/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4884.00","DECISION_PENALTY_AMT":"1471.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Young","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"150331","VIOLATION_NO":"9294254","DOCKET_NO":"WEVA 2022-0260","DECISION_DT":"10/01/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"661.00","DECISION_PENALTY_AMT":"198.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Young","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"150215","VIOLATION_NO":"9562672","DOCKET_NO":"WEVA 2022-0260","DECISION_DT":"10/01/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"10868.00","DECISION_PENALTY_AMT":"1676.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Young","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"150214","VIOLATION_NO":"9562669","DOCKET_NO":"WEVA 2022-0260","DECISION_DT":"10/01/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4884.00","DECISION_PENALTY_AMT":"1471.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Young","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"459436","VIOLATION_NO":"5090429","DOCKET_NO":"WEVA 2025-0517","DECISION_DT":"09/29/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2133.00","DECISION_PENALTY_AMT":"2133.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2025-09-29"},{"SOURCE_ROW_NUMBER":"166425","VIOLATION_NO":"5090434","DOCKET_NO":"WEVA 2025-0517","DECISION_DT":"09/29/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2133.00","DECISION_PENALTY_AMT":"2133.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2025-09-29"},{"SOURCE_ROW_NUMBER":"456413","VIOLATION_NO":"9837737","DOCKET_NO":"WEVA 2025-0394","DECISION_DT":"08/08/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"818.00","DECISION_PENALTY_AMT":"818.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2025-08-08"},{"SOURCE_ROW_NUMBER":"456345","VIOLATION_NO":"9837740","DOCKET_NO":"WEVA 2025-0394","DECISION_DT":"08/08/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"755.00","DECISION_PENALTY_AMT":"755.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2025-08-08"},{"SOURCE_ROW_NUMBER":"455479","VIOLATION_NO":"9835545","DOCKET_NO":"WEVA 2025-0312","DECISION_DT":"07/11/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2936.00","DECISION_PENALTY_AMT":"267.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2025-07-11"},{"SOURCE_ROW_NUMBER":"455854","VIOLATION_NO":"9835527","DOCKET_NO":"WEVA 2025-0270","DECISION_DT":"06/18/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1679.00","DECISION_PENALTY_AMT":"1679.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2025-06-18"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":3995,"firstDate":"2017-06-12","lastDate":"2026-10-07","metrics":{"recentRows":2079,"cpdmSamples":3554,"voidSamples":883,"validSamples":3112,"maxConcentration":2.912,"concentrationTotal":1725.156},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2688322","SMP_TAKEN_DT":"10/7/2026","CONC":".047","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2688316","SMP_TAKEN_DT":"10/7/2026","CONC":".105","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2005466","SMP_TAKEN_DT":"10/6/2026","CONC":".045","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"1835994","SMP_TAKEN_DT":"10/6/2026","CONC":".1","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2005350","SMP_TAKEN_DT":"10/5/2026","CONC":".076","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"3029474","SMP_TAKEN_DT":"7/21/2026","CONC":".005","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-07-21"},{"SOURCE_ROW_NUMBER":"3029215","SMP_TAKEN_DT":"7/21/2026","CONC":"1.03","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-07-21"},{"SOURCE_ROW_NUMBER":"1750706","SMP_TAKEN_DT":"7/20/2026","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-07-20"},{"SOURCE_ROW_NUMBER":"1836944","SMP_TAKEN_DT":"7/16/2026","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-07-16"},{"SOURCE_ROW_NUMBER":"1751213","SMP_TAKEN_DT":"7/16/2026","CONC":".011","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-07-16"},{"SOURCE_ROW_NUMBER":"2859113","SMP_TAKEN_DT":"7/15/2026","CONC":".076","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-07-15"},{"SOURCE_ROW_NUMBER":"2518386","SMP_TAKEN_DT":"7/15/2026","CONC":".014","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-07-15"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":24,"firstDate":"2018-03-26","lastDate":"2024-07-15","metrics":{"linkedIssuances":24},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":274,"firstDate":"2017-08-29","lastDate":"2025-05-05","metrics":{"decisions":273,"ssChanged":24,"recentRows":136,"decisionPenalty":292453,"proposedPenalty":557544},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"334862","CITATION_NO":"5090434","CITATION_ISSUE_DT":"05/05/2025","DOCKET_NO":"WEVA 2025-0517","DECISION_DT":"09/29/2025","CFR_STANDARD_CODE":"75.604(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2133.00","DECISION_PENALTY_AMT":"2133.00","sourceDate":"2025-05-05"},{"SOURCE_ROW_NUMBER":"168220","CITATION_NO":"5090429","CITATION_ISSUE_DT":"04/30/2025","DOCKET_NO":"WEVA 2025-0517","DECISION_DT":"09/29/2025","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"2133.00","DECISION_PENALTY_AMT":"2133.00","sourceDate":"2025-04-30"},{"SOURCE_ROW_NUMBER":"280011","CITATION_NO":"9837740","CITATION_ISSUE_DT":"02/26/2025","DOCKET_NO":"WEVA 2025-0394","DECISION_DT":"08/08/2025","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"755.00","DECISION_PENALTY_AMT":"755.00","sourceDate":"2025-02-26"},{"SOURCE_ROW_NUMBER":"337312","CITATION_NO":"9837737","CITATION_ISSUE_DT":"02/24/2025","DOCKET_NO":"WEVA 2025-0394","DECISION_DT":"08/08/2025","CFR_STANDARD_CODE":"75.337(h)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"818.00","DECISION_PENALTY_AMT":"818.00","sourceDate":"2025-02-24"},{"SOURCE_ROW_NUMBER":"221684","CITATION_NO":"9835545","CITATION_ISSUE_DT":"01/29/2025","DOCKET_NO":"WEVA 2025-0312","DECISION_DT":"07/11/2025","CFR_STANDARD_CODE":"72.630(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"2936.00","DECISION_PENALTY_AMT":"267.00","sourceDate":"2025-01-29"},{"SOURCE_ROW_NUMBER":"167437","CITATION_NO":"9835541","CITATION_ISSUE_DT":"12/27/2024","DOCKET_NO":"WEVA 2025-0270","DECISION_DT":"06/18/2025","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3448.00","DECISION_PENALTY_AMT":"3448.00","sourceDate":"2024-12-27"},{"SOURCE_ROW_NUMBER":"222232","CITATION_NO":"9835527","CITATION_ISSUE_DT":"12/18/2024","DOCKET_NO":"WEVA 2025-0270","DECISION_DT":"06/18/2025","CFR_STANDARD_CODE":"75.604(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1679.00","DECISION_PENALTY_AMT":"1679.00","sourceDate":"2024-12-18"},{"SOURCE_ROW_NUMBER":"449223","CITATION_NO":"9832936","CITATION_ISSUE_DT":"09/24/2024","DOCKET_NO":"WEVA 2025-0145","DECISION_DT":"03/05/2025","CFR_STANDARD_CODE":"75.208","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"4628.00","DECISION_PENALTY_AMT":"2080.00","sourceDate":"2024-09-24"},{"SOURCE_ROW_NUMBER":"395491","CITATION_NO":"9830840","CITATION_ISSUE_DT":"09/19/2024","DOCKET_NO":"WEVA 2025-0145","DECISION_DT":"03/05/2025","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"7481.00","DECISION_PENALTY_AMT":"3362.00","sourceDate":"2024-09-19"},{"SOURCE_ROW_NUMBER":"168260","CITATION_NO":"9834561","CITATION_ISSUE_DT":"08/29/2024","DOCKET_NO":"WEVA 2025-0078","DECISION_DT":"03/05/2025","CFR_STANDARD_CODE":"75.360(f)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"626.00","DECISION_PENALTY_AMT":".00","sourceDate":"2024-08-29"},{"SOURCE_ROW_NUMBER":"451743","CITATION_NO":"9834553","CITATION_ISSUE_DT":"08/19/2024","DOCKET_NO":"WEVA 2025-0078","DECISION_DT":"03/05/2025","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"935.00","DECISION_PENALTY_AMT":"935.00","sourceDate":"2024-08-19"},{"SOURCE_ROW_NUMBER":"111637","CITATION_NO":"9834551","CITATION_ISSUE_DT":"08/19/2024","DOCKET_NO":"WEVA 2025-0078","DECISION_DT":"03/05/2025","CFR_STANDARD_CODE":"75.1722(c)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2079.00","DECISION_PENALTY_AMT":"2079.00","sourceDate":"2024-08-19"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":1438,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":10,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":337,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":10,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2014-07-31","lastDate":"2014-07-31","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":116,"firstDate":"2014-09-29","lastDate":"2026-10-01","metrics":{"inspectors":280,"recentRows":51,"onSiteHours":4795.25,"inspectionHours":7521.25,"inspectionSamples":295},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"139413","EVENT_NO":"F03DF79","INSPECTION_BEGIN_DT":"10/01/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.75","SUM_TOTAL_ON_SITE_HOURS":"7.25","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"590646","EVENT_NO":"F00EB07","INSPECTION_BEGIN_DT":"07/28/2026","INSPECTION_END_DT":"08/20/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"80.75","SUM_TOTAL_ON_SITE_HOURS":"49","sourceDate":"2026-07-28"},{"SOURCE_ROW_NUMBER":"2991","EVENT_NO":"7048878","INSPECTION_BEGIN_DT":"04/01/2026","INSPECTION_END_DT":"04/21/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"100","SUM_TOTAL_ON_SITE_HOURS":"73.5","sourceDate":"2026-04-01"},{"SOURCE_ROW_NUMBER":"419858","EVENT_NO":"F010C65","INSPECTION_BEGIN_DT":"03/05/2026","INSPECTION_END_DT":"03/26/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"59.5","SUM_TOTAL_ON_SITE_HOURS":"43.75","sourceDate":"2026-03-05"},{"SOURCE_ROW_NUMBER":"726401","EVENT_NO":"F02EC70","INSPECTION_BEGIN_DT":"11/24/2025","INSPECTION_END_DT":"11/24/2025","ACTIVITY_CODE":"E03","ACTIVITY":"103 (g) Written Notification Hazard Complaint Inspectio","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"3.75","sourceDate":"2025-11-24"},{"SOURCE_ROW_NUMBER":"462356","EVENT_NO":"7048872","INSPECTION_BEGIN_DT":"10/01/2025","INSPECTION_END_DT":"12/17/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"114.5","SUM_TOTAL_ON_SITE_HOURS":"85.25","sourceDate":"2025-10-01"},{"SOURCE_ROW_NUMBER":"1057105","EVENT_NO":"F00A0FB","INSPECTION_BEGIN_DT":"08/19/2025","INSPECTION_END_DT":"08/29/2025","ACTIVITY_CODE":"E19","ACTIVITY":"Electrical Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"22.5","SUM_TOTAL_ON_SITE_HOURS":"14.5","sourceDate":"2025-08-19"},{"SOURCE_ROW_NUMBER":"25262","EVENT_NO":"7048317","INSPECTION_BEGIN_DT":"07/01/2025","INSPECTION_END_DT":"07/17/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"96.25","SUM_TOTAL_ON_SITE_HOURS":"69.5","sourceDate":"2025-07-01"},{"SOURCE_ROW_NUMBER":"547336","EVENT_NO":"7048310","INSPECTION_BEGIN_DT":"04/01/2025","INSPECTION_END_DT":"05/29/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"188","SUM_TOTAL_ON_SITE_HOURS":"135.5","sourceDate":"2025-04-01"},{"SOURCE_ROW_NUMBER":"698042","EVENT_NO":"F009F3E","INSPECTION_BEGIN_DT":"02/24/2025","INSPECTION_END_DT":"03/31/2025","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"43.5","SUM_TOTAL_ON_SITE_HOURS":"24.75","sourceDate":"2025-02-24"},{"SOURCE_ROW_NUMBER":"566813","EVENT_NO":"7048865","INSPECTION_BEGIN_DT":"01/02/2025","INSPECTION_END_DT":"03/24/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"9","SUM_TOTAL_INSP_HOURS":"290.75","SUM_TOTAL_ON_SITE_HOURS":"180.5","sourceDate":"2025-01-02"},{"SOURCE_ROW_NUMBER":"1020134","EVENT_NO":"7048862","INSPECTION_BEGIN_DT":"10/01/2024","INSPECTION_END_DT":"12/28/2024","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"147.5","SUM_TOTAL_ON_SITE_HOURS":"87.5","sourceDate":"2024-10-01"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":104,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2026-Q2":{"hours":6665,"employees":10,"production":0},"2026-Q1":{"hours":3717,"employees":6,"production":0},"2025-Q4":{"hours":2284,"employees":10,"production":0},"2025-Q3":{"hours":2200,"employees":8,"production":0},"2025-Q2":{"hours":25155,"employees":35,"production":39459},"2025-Q1":{"hours":33760,"employees":48,"production":57099},"2024-Q4":{"hours":31956,"employees":50,"production":54589},"2024-Q3":{"hours":35863,"employees":51,"production":67002},"2024-Q2":{"hours":40144,"employees":54,"production":53394},"2024-Q1":{"hours":41991,"employees":56,"production":53626},"2023-Q4":{"hours":43202,"employees":55,"production":36659},"2023-Q3":{"hours":36890,"employees":55,"production":73157}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":28,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017":{"hours":59282,"employees":39,"production":215081},"2018":{"hours":121224,"employees":52,"production":539184},"2019":{"hours":129628,"employees":55,"production":488334},"2020":{"hours":132839,"employees":53,"production":488638},"2021":{"hours":150692,"employees":55,"production":670873},"2022":{"hours":140680,"employees":53,"production":316877},"2023":{"hours":155960,"employees":54,"production":301726},"2024":{"hours":149954,"employees":57,"production":228611},"2025":{"hours":63399,"employees":25,"production":96558},"2026":{"hours":10382,"employees":8,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":110,"firstDate":"2017-07-26","lastDate":"2026-04-20","metrics":{"recentRows":43,"doseOver100":14,"actDoseTotal":6711,"pelDoseTotal":4609},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"268375","EVENT_NO":"7048878","SURVEY_DATE":"04/20/2026","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"20","ACT_DOSE_85":"8","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2026-04-20"},{"SOURCE_ROW_NUMBER":"268374","EVENT_NO":"7048878","SURVEY_DATE":"04/20/2026","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"20","ACT_DOSE_85":"11","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2026-04-20"},{"SOURCE_ROW_NUMBER":"268373","EVENT_NO":"7048878","SURVEY_DATE":"04/20/2026","OCCUPATION_CD_DESC":"FIRE BOSS PRE-SHIFT EXAMINER","MACHINE_CD":"20","ACT_DOSE_85":"9","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2026-04-20"},{"SOURCE_ROW_NUMBER":"268372","EVENT_NO":"7048862","SURVEY_DATE":"11/20/2024","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"70","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2024-11-20"},{"SOURCE_ROW_NUMBER":"268371","EVENT_NO":"7048862","SURVEY_DATE":"11/20/2024","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"40","ACT_DOSE_85":"47","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2024-11-20"},{"SOURCE_ROW_NUMBER":"268370","EVENT_NO":"7048862","SURVEY_DATE":"11/20/2024","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"64","PEL_DOSE_90":"40","SURVEY_TYPE":"I","sourceDate":"2024-11-20"},{"SOURCE_ROW_NUMBER":"268369","EVENT_NO":"7048862","SURVEY_DATE":"11/20/2024","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"105","PEL_DOSE_90":"81","SURVEY_TYPE":"I","sourceDate":"2024-11-20"},{"SOURCE_ROW_NUMBER":"268368","EVENT_NO":"7048862","SURVEY_DATE":"11/20/2024","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"85","PEL_DOSE_90":"67","SURVEY_TYPE":"I","sourceDate":"2024-11-20"},{"SOURCE_ROW_NUMBER":"268367","EVENT_NO":"7048862","SURVEY_DATE":"11/20/2024","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","ACT_DOSE_85":"24","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2024-11-20"},{"SOURCE_ROW_NUMBER":"268366","EVENT_NO":"7048862","SURVEY_DATE":"11/20/2024","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","ACT_DOSE_85":"33","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2024-11-20"},{"SOURCE_ROW_NUMBER":"268365","EVENT_NO":"7048862","SURVEY_DATE":"11/20/2024","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"104","PEL_DOSE_90":"86","SURVEY_TYPE":"I","sourceDate":"2024-11-20"},{"SOURCE_ROW_NUMBER":"268364","EVENT_NO":"7048862","SURVEY_DATE":"11/20/2024","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"54","PEL_DOSE_90":"37","SURVEY_TYPE":"I","sourceDate":"2024-11-20"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":148,"firstDate":"2017-06-29","lastDate":"2025-05-08","metrics":{"recentRows":79,"voidSamples":2,"maxQuartzPct":16,"validSamples":146,"quartzPctTotal":841.2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"138317","CASSETTE_NO":"58552154","SAMPLE_DT":"05/08/2025","QUARTZ_PCT":"07.2","QUARTZ_MICROGRAMS":"11","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-05-08"},{"SOURCE_ROW_NUMBER":"78609","CASSETTE_NO":"58552152","SAMPLE_DT":"05/08/2025","QUARTZ_PCT":"03.0","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-05-08"},{"SOURCE_ROW_NUMBER":"73798","CASSETTE_NO":"58552159","SAMPLE_DT":"05/08/2025","QUARTZ_PCT":"06.5","QUARTZ_MICROGRAMS":"9","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-05-08"},{"SOURCE_ROW_NUMBER":"73719","CASSETTE_NO":"58551956","SAMPLE_DT":"05/08/2025","QUARTZ_MICROGRAMS":"0","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-05-08"},{"SOURCE_ROW_NUMBER":"8508","CASSETTE_NO":"58552138","SAMPLE_DT":"05/08/2025","QUARTZ_PCT":"06.4","QUARTZ_MICROGRAMS":"20","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-05-08"},{"SOURCE_ROW_NUMBER":"164049","CASSETTE_NO":"58513921","SAMPLE_DT":"03/12/2025","QUARTZ_PCT":"02.0","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-03-12"},{"SOURCE_ROW_NUMBER":"103625","CASSETTE_NO":"58513977","SAMPLE_DT":"03/12/2025","QUARTZ_PCT":"06.1","QUARTZ_MICROGRAMS":"17","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-03-12"},{"SOURCE_ROW_NUMBER":"99111","CASSETTE_NO":"58513916","SAMPLE_DT":"03/12/2025","QUARTZ_PCT":"00.9","QUARTZ_MICROGRAMS":"1","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-03-12"},{"SOURCE_ROW_NUMBER":"34153","CASSETTE_NO":"58513976","SAMPLE_DT":"03/12/2025","QUARTZ_PCT":"04.7","QUARTZ_MICROGRAMS":"12","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-03-12"},{"SOURCE_ROW_NUMBER":"30767","CASSETTE_NO":"58513953","SAMPLE_DT":"03/12/2025","QUARTZ_PCT":"05.3","QUARTZ_MICROGRAMS":"14","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-03-12"},{"SOURCE_ROW_NUMBER":"19193","CASSETTE_NO":"58513960","SAMPLE_DT":"03/12/2025","QUARTZ_MICROGRAMS":"0","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-03-12"},{"SOURCE_ROW_NUMBER":"135636","CASSETTE_NO":"58512467","SAMPLE_DT":"11/20/2024","QUARTZ_PCT":"06.2","QUARTZ_MICROGRAMS":"65","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2024-11-20"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":1006,"firstDate":"2016-11-08","lastDate":"2026-10-08","metrics":{"ss":171,"amountDue":665840,"contested":0,"amountPaid":634233,"recentRows":663,"section104d":0,"unterminated":1,"proposedPenalty":916321.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2972211","VIOLATION_NO":"5131849","VIOLATION_ISSUE_DT":"10/08/2026","SIG_SUB":"N","PART_SECTION":"77.1109(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/08/2026","CONTESTED_IND":"N","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2972210","VIOLATION_NO":"5131848","VIOLATION_ISSUE_DT":"10/06/2026","SIG_SUB":"N","PART_SECTION":"75.1100-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2972209","VIOLATION_NO":"5131847","VIOLATION_ISSUE_DT":"10/06/2026","SIG_SUB":"N","PART_SECTION":"75.904","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2972208","VIOLATION_NO":"5131846","VIOLATION_ISSUE_DT":"10/05/2026","SIG_SUB":"N","PART_SECTION":"75.1731(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"2972207","VIOLATION_NO":"5131845","VIOLATION_ISSUE_DT":"10/05/2026","SIG_SUB":"N","PART_SECTION":"75.351(n)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/05/2026","CONTESTED_IND":"N","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"2972206","VIOLATION_NO":"5131844","VIOLATION_ISSUE_DT":"10/05/2026","SIG_SUB":"Y","PART_SECTION":"77.400(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/05/2026","CONTESTED_IND":"N","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"2972205","VIOLATION_NO":"5131843","VIOLATION_ISSUE_DT":"10/01/2026","SIG_SUB":"N","PART_SECTION":"75.209(f)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/05/2026","CONTESTED_IND":"N","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"2972037","VIOLATION_NO":"5098916","VIOLATION_ISSUE_DT":"08/19/2026","SIG_SUB":"N","PART_SECTION":"75.1731(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/19/2026","CONTESTED_IND":"N","sourceDate":"2026-08-19"},{"SOURCE_ROW_NUMBER":"2972036","VIOLATION_NO":"5098915","VIOLATION_ISSUE_DT":"08/19/2026","SIG_SUB":"N","PART_SECTION":"75.333(c)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/19/2026","CONTESTED_IND":"N","sourceDate":"2026-08-19"},{"SOURCE_ROW_NUMBER":"2972035","VIOLATION_NO":"5098914","VIOLATION_ISSUE_DT":"08/17/2026","SIG_SUB":"N","PART_SECTION":"75.204(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/17/2026","CONTESTED_IND":"N","sourceDate":"2026-08-17"},{"SOURCE_ROW_NUMBER":"2972034","VIOLATION_NO":"5098913","VIOLATION_ISSUE_DT":"08/12/2026","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/17/2026","CONTESTED_IND":"N","sourceDate":"2026-08-12"},{"SOURCE_ROW_NUMBER":"2972033","VIOLATION_NO":"5098910","VIOLATION_ISSUE_DT":"08/03/2026","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/04/2026","PROPOSED_PENALTY":"165","AMOUNT_DUE":"165","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-08-03"}]}],"safety":{"href":"/api/v1/mines/4609495/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609495/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":{"averageEmployees":53,"companyType":"Operating Subsidiary","components":[{"averageEmployees":53,"laborHours":149954,"mineType":"Underground","productionTons":228611}],"county":"Logan","laborHours":149954,"mineName":"Eagle Seam Deep Mine","mineType":"Underground","mshaId":"4609495","operatingAddress":"P.O. Box 219, Verner, WV 25650","operatingCompany":"Ramaco Resources, Llc","operationType":"Mine only","productionTons":228611,"reportedRows":1,"sourceUrl":"https://www.eia.gov/coal/data/public/xls/coalpublic2024.xlsx","state":"West Virginia (Southern)","status":"Active, men working, not producing","supplyRegion":"Appalachia Central","union":"","year":2024},"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-3","heading":"Condition and examination of firefighting equipment.","id":"75.1100-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"All firefighting equipment shall be maintained in a usable and operative condition. Chemical extinguishers shall be examined every 6 months and the date of the examination shall be written on a permanent tag attached to the extinguisher.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.904","heading":"Identification of circuit breakers.","id":"75.904","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-J/section-75.904","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"J","subpartHeading":"Subpart J—Underground Low- and Medium-Voltage Alternating Current Circuits","text":"[Statutory Provisions]\n\nCircuit breakers shall be marked for identification.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1731","heading":"Maintenance of belt conveyors and belt conveyor entries.","id":"75.1731","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1731","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Damaged rollers, or other damaged belt conveyor components, which pose a fire hazard must be immediately repaired or replaced. All other damaged rollers, or other damaged belt conveyor components, must be repaired or replaced.\n\n(b) Conveyor belts must be properly aligned to prevent the moving belt from rubbing against the structure or components.\n\n(c) Materials shall not be allowed in the belt conveyor entry where the material may contribute to a frictional heating hazard.\n\n(d) Splicing of any approved conveyor belt must maintain flame-resistant properties of the belt.\n\n[73 FR 80616, Dec. 31, 2008]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.351","heading":"Atmospheric monitoring systems.","id":"75.351","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.351","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) AMS operation. Whenever personnel are underground and an AMS is used to fulfill the requirements of §§ 75.323(d)(1)(ii), 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), 75.350(d), or 75.362(f), the AMS must be operating and a designated AMS operator must be on duty at a location on the surface of the mine where audible and visual signals from the AMS must be seen or heard and the AMS operator can promptly respond to these signals.\n\n(b) Designated surface location and AMS operator. When an AMS is used to comply with §§ 75.323(d)(1)(ii), 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), 75.350(d), or 75.362(f), the following requirements apply:\n\n(1) The mine operator must designate a surface location at the mine where signals from the AMS will be received and two-way voice communication is maintained with each working section, with areas where mechanized mining equipment is being installed or removed, and with other areas designated in the approved emergency evacuation and firefighting program of instruction (§ 75.1502).\n\n(2) The mine operator must designate an AMS operator to monitor and promptly respond to all AMS signals. The AMS operator must have as a primary duty the responsibility to monitor the malfunction, alert and alarm signals of the AMS, and to notify appropriate personnel of these signals. In the event of an emergency, the sole responsibility of the AMS operator shall be to respond to the emergency.\n\n(3) A map or schematic must be provided at the designated surface location that shows the locations and type of AMS sensor at each location, and the intended air flow direction at these locations. This map or schematic must be updated within 24 hours of any change in this information.\n\n(4) The names of the designated AMS operators and other appropriate personnel, including the designated person responsible for initiating an emergency mine evacuation under § 75.1501, and the method to contact these persons, must be provided at the designated surface location.\n\n(c) Minimum operating requirements. AMSs used to comply with §§ 75.323(d)(1)(ii), 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), 75.350(d), or 75.362(f) must:\n\n(1) Automatically provide visual and audible signals at the designated surface location for any interruption of circuit continuity and any electrical malfunction of the system. These signals must be of sufficient magnitude to be seen or heard by the AMS operator.\n\n(2) Automatically provide visual and audible signals at the designated surface location when the carbon monoxide concentration or methane concentration at any sensor reaches the alert level as specified in § 75.351(i). These signals must be of sufficient magnitude to be seen or heard by the AMS operator.\n\n(3) Automatically provide visual and audible signals at the designated surface location distinguishable from alert signals when the carbon monoxide, smoke, or methane concentration at any sensor reaches the alarm level as specified in § 75.351(i). These signals must be of sufficient magnitude to be seen or heard by the AMS operator.\n\n(4) Automatically provide visual and audible signals at all affected working sections and at all affected areas where mechanized mining equipment is being installed or removed when the carbon monoxide, smoke, or methane concentration at any sensor reaches the alarm level as specified in § 75.351(i). These signals must be of sufficient magnitude to be seen or heard by miners working at these locations. Methane signals must be distinguishable from other signals.\n\n(5) Automatically provide visual and audible signals at other locations as specified in Mine Emergency Evacuation and Firefighting Program of Instruction (§ 75.1502) when the carbon monoxide, smoke, or methane concentration at any sensor reaches the alarm level as specified in § 75.351(i). These signals must be seen or heard by miners working at these locations. Methane alarms must be distinguishable from other signals.\n\n(6) Identify at the designated surface location the operational status of all sensors.\n\n(7) Automatically provide visual and audible alarm signals at the designated surface location, at all affected working sections, and at all affected areas where mechanized mining equipment is being installed or removed when the carbon monoxide level at any two consecutive sensors alert at the same time. These signals must be seen or heard by the AMS operator and miners working at these locations.\n\n(d) Location and installation of AMS sensors. (1) All AMS sensors, as specified in §§ 75.351(e) through 75.351(h), must be located such that measurements are representative of the mine atmosphere in these locations.\n\n(2) Carbon monoxide or smoke sensors must be installed near the center in the upper third of the entry, in a location that does not expose personnel working on the system to unsafe conditions. Sensors must not be located in abnormally high areas or in other locations where air flow patterns do not permit products of combustion to be carried to the sensors.\n\n(3) Methane sensors must be installed near the center of the entry, at least 12 inches from the roof, ribs, and floor, in a location that would not expose personnel working on the system to unsafe conditions.\n\n(e) Location of sensors-belt air course. (1) In addition to the requirements of paragraph (d) of this section, any AMS used to monitor belt air courses under § 75.350(b) must have approved sensors to monitor for carbon monoxide at the following locations:\n\n(i) At or near the working section belt tailpiece in the air stream ventilating the belt entry. In longwall mining systems the sensor must be located upwind in the belt entry at a distance no greater than 150 feet from the mixing point where intake air is mixed with the belt air at or near the tailpiece;\n\n(ii) No more than 50 feet upwind from the point where the belt air course is combined with another air course or splits into multiple air courses;\n\n(iii) At intervals not to exceed 1,000 feet along each belt entry. However, in areas along each belt entry where air velocities are between 50 and 100 feet per minute, spacing of sensors must not exceed 500 feet. In areas along each belt entry where air velocities are less than 50 feet per minute, the sensor spacing must not exceed 350 feet;\n\n(iv) Not more than 100 feet downwind of each belt drive unit, each tailpiece, transfer point, and each belt take-up. If the belt drive, tailpiece, and/or take-up for a single transfer point are installed together in the same air course, and the distance between the units is less than 100 feet, they may be monitored with one sensor downwind of the last component. If the distance between the units exceeds 100 feet, additional sensors are required downwind of each belt drive unit, each tailpiece, transfer point, and each belt take-up; and\n\n(v) At other locations in any entry that is part of the belt air course as required and specified in the mine ventilation plan.\n\n(2) Smoke sensors must be installed to monitor the belt entry under § 75.350(b) at the following locations:\n\n(i) At or near the working section belt tailpiece in the air stream ventilating the belt entry. In longwall mining systems the sensor must be located upwind in the belt entry at a distance no greater than 150 feet from the mixing point where intake air is mixed with the belt air at or near the tailpiece;\n\n(ii) Not more than 100 feet downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up. If the belt drive, tailpiece, and/or take-up for a single transfer point are installed together in the same air course, and the distance between the units is less than 100 feet, they may be monitored with one sensor downwind of the last component. If the distance between the units exceeds 100 feet, additional sensors are required downwind of each belt drive unit, each tailpiece, transfer point, and each belt take-up; and\n\n(iii) At intervals not to exceed 3,000 feet along each belt entry.\n\n(iv) This provision shall be effective one year after the Secretary has determined that a smoke sensor is available to reliably detect fire in underground coal mines.\n\n(f) Locations of sensors—the primary escapeway. When used to monitor the primary escapeway under § 75.350(b)(4), carbon monoxide or smoke sensors must be located in the primary escapeway within 500 feet of the working section and areas where mechanized mining equipment is being installed or removed. In addition, another sensor must be located within 500 feet inby the beginning of the panel. The point-feed sensor required by § 75.350(d)(1) may be used as the sensor at the beginning of the panel if it is located within 500 feet inby the beginning of the panel.\n\n(g) Location of sensors—return air splits. (1) If used to monitor return air splits under § 75.362(f), a methane sensor must be installed in the return air split between the last working place, longwall or shortwall face ventilated by that air split, and the junction of the return air split with another air split, seal, or worked out area.\n\n(2) If used to monitor a return air split under § 75.323(d)(1)(ii), the methane sensors must be installed at the following locations:\n\n(i) In the return air course opposite the section loading point, or, if exhausting auxiliary fan(s) are used, in the return air course no closer than 300 feet downwind from the fan exhaust and at a point opposite or immediately outby the section loading point; and\n\n(ii) Immediately upwind from the location where the return air split meets another air split or immediately upwind of the location where an air split is used to ventilate seals or worked-out areas.\n\n(h) Location of sensors—electrical installations. When monitoring the intake air ventilating underground transformer stations, battery charging stations, substations, rectifiers, or water pumps under § 75.340(a)(1)(ii) or § 75.340(a)(2)(ii), at least one sensor must be installed to monitor the mine atmosphere for carbon monoxide or smoke, located downwind and not greater than 50 feet from the electrical installation being monitored.\n\n(i) Establishing alert and alarm levels. An AMS installed in accordance with the following paragraphs must initiate alert and alarm signals at the specified levels, as indicated:\n\n(1) For § 75.323(d)(1)(ii) alarm at 1.5% methane.\n\n(2) For §§ 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), and 75.350(d), alert at 5 ppm carbon monoxide above the ambient level and alarm at 10 ppm carbon monoxide above the ambient level when carbon monoxide sensors are used; and alarm at a smoke optical density of 0.022 per meter when smoke sensors are used. Reduced alert and alarm settings approved by the district manager may be required for carbon monoxide sensors identified in the mine ventilation plan, § 75.371(nn).\n\n(3) For § 75.362(f), alert at 1.0% methane and alarm at 1.5% methane.\n\n(j) Establishing carbon monoxide ambient levels. Carbon monoxide ambient levels and the means to determine these levels must be approved in the mine ventilation plan (§ 75.371(hh)) for monitors installed in accordance with §§ 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), and 75.350(d).\n\n(k) Installation and maintenance. An AMS installed in accordance with §§ 75.323(d)(1)(ii), 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), 75.350(d), or 75.362(f) must be installed and maintained by personnel trained in the installation and maintenance of the system. The system must be maintained in proper operating condition.\n\n(l) Sensors. Sensors used to monitor for carbon monoxide, methane, and smoke must be either of a type listed and installed in accordance with the recommendations of a nationally recognized testing laboratory approved by the Secretary; or these sensors must be of a type, and installed in a manner, approved by the Secretary.\n\n(m) Time delays. When a demonstrated need exists, time delays may be incorporated into the AMS. These time delays must only be used to account for non-fire related carbon monoxide alert and alarm sensor signals. These time delays are limited to no more than three minutes. The use and length of any time delays, or other techniques or methods which eliminate or reduce the need for time delays, must be specified and approved in the mine ventilation plan.\n\n(n) Examination, testing, and calibration. (1) At least once each shift when belts are operated as part of a production shift, sensors used to detect carbon monoxide or smoke in accordance with §§ 75.350(b), and 75.350(d), and alarms installed in accordance with § 75.350(b) must be visually examined.\n\n(2) At least once every seven days, alarms for AMS installed in accordance with §§ 75.350(b), and 75.350(d) must be functionally tested for proper operation.\n\n(3) At intervals not to exceed 31 days—\n\n(i) Each carbon monoxide sensor installed in accordance with §§ 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), or 75.350(d) must be calibrated in accordance with the manufacturer's calibration specifications. Calibration must be done with a known concentration of carbon monoxide in air sufficient to activate the alarm;\n\n(ii) Each smoke sensor installed in accordance with §§ 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), or 75.350(d) must be functionally tested in accordance with the manufacturer's calibration specifications;\n\n(iii) Each methane sensor installed in accordance with §§ 75.323(d)(1)(ii) or 75.362(f) must be calibrated in accordance with the manufacturer's calibration specifications. Calibration must be done with a known concentration of methane in air sufficient to activate an alarm.\n\n(iv) If the alert or alarm signals will be activated during calibration of sensors, the AMS operator must be notified prior to and upon completion of calibration. The AMS operator must notify miners on affected working sections, areas where mechanized mining equipment is being installed or removed, or other areas designated in the approved emergency evacuation and firefighting program of instruction (§ 75.1502) when calibration will activate alarms and when calibration is completed.\n\n(4) Gases used for the testing and calibration of AMS sensors must be traceable to the National Institute of Standards and Technology reference standard for the specific gas. When these reference standards are not available for a specific gas, calibration gases must be traceable to an analytical standard which is prepared using a method traceable to the National Institute of Standards and Technology. Calibration gases must be within ±2.0 percent of the indicated gas concentration.\n\n(o) Recordkeeping. (1) When an AMS is used to comply with §§ 75.323(d)(1)(ii), 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), 75.350(d), or 75.362(f), individuals designated by the operator must make the following records by the end of the shift in which the following event(s) occur:\n\n(i) If an alert or alarm signal occurs, a record of the date, time, location and type of sensor, and the cause for the activation.\n\n(ii) If an AMS malfunctions, a record of the date, the extent and cause of the malfunction, and the corrective action taken to return the system to proper operation.\n\n(iii) A record of the seven-day tests of alert and alarm signals; calibrations; and maintenance of the AMS must be made by the person(s) performing these actions.\n\n(2) The person entering the record must include their name, date, and signature in the record.\n\n(3) The records required by this section must be kept either in a secure book that is not susceptible to alteration, or electronically in a computer system that is secure and not susceptible to alteration. These records must be maintained separately from other records and identifiable by a title, such as the ‘AMS log.’\n\n(p) Retention period. Records must be retained for at least one year at a surface location at the mine and made available for inspection by miners and authorized representatives of the Secretary.\n\n(q) Training. (1) All AMS operators must be trained annually in the proper operation of the AMS. This training must include the following subjects:\n\n(i) Familiarity with underground mining systems;\n\n(ii) Basic atmospheric monitoring system requirements;\n\n(iii) The mine emergency evacuation and firefighting program of instruction;\n\n(iv) The mine ventilation system including planned air directions;\n\n(v) Appropriate response to alert, alarm and malfunction signals;\n\n(vi) Use of mine communication systems including emergency notification procedures; and\n\n(vii) AMS recordkeeping requirements.\n\n(2) At least once every six months, all AMS operators must travel to all working sections.\n\n(3) A record of the content of training, the person conducting the training, and the date the training was conducted, must be maintained at the mine for at least one year by the mine operator.\n\n(r) Communications. When an AMS is used to comply with § 75.350(b), a two-way voice communication system required by § 75.1600 must be installed in an entry that is separate from the entry in which the AMS is installed no later than August 2, 2004. The two-way voice communication system may be installed in the entry where the intake sensors required by §§ 75.350(b)(4) or 75.350(d)(1) are installed.\n\n[69 FR 17527, Apr. 2, 2004, as amended at 73 FR 80612, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.400","heading":"Mechanical equipment guards.","id":"77.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.400","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings; shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Overhead belts shall be guarded if the whipping action from a broken line would be hazardous to persons below.\n\n(c) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(d) Except when testing the machinery, guards shall be securely in place while machinery is being operated.","occurrenceCount":1},{"chapter":"I","heading":"Automated Temporary Roof Support (ATRS) systems.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.209","part":"75","subchapter":"O","subpart":"C","id":"75.209","citation":"30 CFR 75.209","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","heading":"Roof bolting.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.204","part":"75","subchapter":"O","subpart":"C","id":"75.204","citation":"30 CFR 75.204","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609495","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}