{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4609474","name":"BELCHER BRANCH","status":"Active","status_date":"2026-10-06","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Wyoming","nearest_town":"Pineville","operator_id":"0083104","operator_name":"Frontier Coal Company","controller_id":"0171761","controller_name":"James C  Justice III","district":"C04","office":"Beckley Field Office","employees":11,"latitude":37.546389,"longitude":-81.504444},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":5507},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609474","name":"BELCHER BRANCH"},"operator":{"type":"operator","id":"0083104","name":"Frontier Coal Company"},"controller":{"type":"controller","id":"0171761","name":"James C  Justice III"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C04355","name":"James C  Justice II et al"},"object":{"type":"mine","id":"4609474","name":"BELCHER BRANCH"},"validFrom":"2007-08-29","validTo":"2009-05-06","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609474|C04355|2007-08-29|2009-05-06"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0085759","name":"Mechel Oao"},"object":{"type":"mine","id":"4609474","name":"BELCHER BRANCH"},"validFrom":"2009-05-07","validTo":"2015-02-11","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609474|0085759|2009-05-07|2015-02-11"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0127993","name":"Energy Plus Inc"},"object":{"type":"mine","id":"4609474","name":"BELCHER BRANCH"},"validFrom":"2013-03-13","validTo":"2021-03-10","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609474|0127993|2013-03-13|2021-03-10"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0085759","name":"Mechel Oao"},"object":{"type":"mine","id":"4609474","name":"BELCHER BRANCH"},"validFrom":"2013-03-13","validTo":"2015-02-11","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609474|0085759|2013-03-13|2015-02-11"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0085759","name":"Mechel Oao"},"object":{"type":"operator","id":"0127993","name":"Energy Plus Inc"},"validFrom":"2013-03-13","validTo":"2015-02-11","current":false,"derived":true,"evidenceMineId":"4609474","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609474|0127993|2013-03-13|0085759|2013-03-13|13759"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C04355","name":"James C  Justice II et al"},"object":{"type":"mine","id":"4609474","name":"BELCHER BRANCH"},"validFrom":"2015-02-12","validTo":"2017-06-07","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609474|C04355|2015-02-12|2017-06-07"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C04355","name":"James C  Justice II et al"},"object":{"type":"mine","id":"4609474","name":"BELCHER BRANCH"},"validFrom":"2015-02-12","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609474|C04355|2015-02-12|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C04355","name":"James C  Justice II et al"},"object":{"type":"operator","id":"0127993","name":"Energy Plus Inc"},"validFrom":"2015-02-12","validTo":"2021-03-10","current":false,"derived":true,"evidenceMineId":"4609474","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609474|0127993|2013-03-13|C04355|2015-02-12|65724"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0091855","name":"James C  Justice lll et al"},"object":{"type":"mine","id":"4609474","name":"BELCHER BRANCH"},"validFrom":"2017-06-08","validTo":"2022-08-23","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609474|0091855|2017-06-08|2022-08-23"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0083104","name":"Frontier Coal Company"},"object":{"type":"mine","id":"4609474","name":"BELCHER BRANCH"},"validFrom":"2021-03-11","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609474|0083104|2021-03-11|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0085759","name":"Mechel Oao"},"object":{"type":"operator","id":"0083104","name":"Frontier Coal Company"},"validFrom":"2021-03-11","validTo":"2015-02-11","current":false,"derived":true,"evidenceMineId":"4609474","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609474|0083104|2021-03-11|0085759|2009-05-07|13757"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0091855","name":"James C  Justice lll et al"},"object":{"type":"operator","id":"0083104","name":"Frontier Coal Company"},"validFrom":"2021-03-11","validTo":"2022-08-23","current":false,"derived":true,"evidenceMineId":"4609474","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609474|0083104|2021-03-11|0091855|2017-06-08|15010"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0091855","name":"Jillean L  Justice et al"},"object":{"type":"operator","id":"0083104","name":"Frontier Coal Company"},"validFrom":"2021-03-11","validTo":"2022-08-23","current":false,"derived":true,"evidenceMineId":"4609474","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609474|0083104|2021-03-11|0091855|2017-06-08|15011"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C04355","name":"James C  Justice II et al"},"object":{"type":"operator","id":"0083104","name":"Frontier Coal Company"},"validFrom":"2021-03-11","validTo":"2009-05-06","current":false,"derived":true,"evidenceMineId":"4609474","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609474|0083104|2021-03-11|C04355|2007-08-29|65551"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C04355","name":"James C  Justice II et al"},"object":{"type":"operator","id":"0083104","name":"Frontier Coal Company"},"validFrom":"2021-03-11","validTo":"2017-06-07","current":false,"derived":true,"evidenceMineId":"4609474","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609474|0083104|2021-03-11|C04355|2015-02-12|65683"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0171761","name":"James C  Justice III"},"object":{"type":"mine","id":"4609474","name":"BELCHER BRANCH"},"validFrom":"2022-08-24","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609474|0171761|2022-08-24|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0171761","name":"James C  Justice III"},"object":{"type":"operator","id":"0083104","name":"Frontier Coal Company"},"validFrom":"2022-08-24","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609474","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609474|0083104|2021-03-11|0171761|2022-08-24|36459"}}],"coverage":{"historyRecords":8,"edgeCount":17,"intervalAnomalies":3,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":28,"firstDate":"2022-10-04","lastDate":"2026-08-29","metrics":{"daysLost":639,"injuries":22,"fatalities":0,"recentRows":28,"restrictedDays":7,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"137290","DOCUMENT_NO":"220262460001","ACCIDENT_DT":"08/29/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"9","NARRATIVE":"Employee was cutting T-3 channel when a small piece of metal shavings broke loose and entered underneath EE's safety glasses, striking the employee in the right eye.","sourceDate":"2026-08-29"},{"SOURCE_ROW_NUMBER":"21290","DOCUMENT_NO":"220262430073","ACCIDENT_DT":"08/29/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"9","NARRATIVE":"EMPLOYEE WAS CUTTING T-3 CHANNEL WHEN A SMALL PIECE OF METAL SHAVINGS BROKE LOOSE AND ENTERED UNDERNEATH THEIR SAFETY GLASSES, STRIKING THE EMPLOYEE IN THE LEFT EYE.","sourceDate":"2026-08-29"},{"SOURCE_ROW_NUMBER":"132893","DOCUMENT_NO":"220262460002","ACCIDENT_DT":"08/04/2026","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"a non injury roof fall occurred on the active working section inby the loading point between no.18 and no.20 in the no.8 entry on the south west panel 4B. The roof fall occurred inby crosscut no. 18 and extended inby the no. 19 crosscut in the no. 9 entry","sourceDate":"2026-08-04"},{"SOURCE_ROW_NUMBER":"25698","DOCUMENT_NO":"220262240017","ACCIDENT_DT":"08/04/2026","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A non injury roof fall occurred on the active working section inby the loading point between crosscut no. 18 and no. 20 in the no. 8 entry on the south west panel 4B. The roof fall occurred inby crosscut no. 18 and extended inby the no. 19 crosscut in the no. 9 entry.","sourceDate":"2026-08-04"},{"SOURCE_ROW_NUMBER":"85760","DOCUMENT_NO":"220262450030","ACCIDENT_DT":"02/26/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Bodily reaction, NEC","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"113","NARRATIVE":"Employee was operating the shuttle car and was switching seats to go back to the feeder when the employee twisted right knee and said that they heard a loud popping sound","sourceDate":"2026-02-26"},{"SOURCE_ROW_NUMBER":"34224","DOCUMENT_NO":"220260620024","ACCIDENT_DT":"02/26/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Bodily reaction, NEC","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"113","NARRATIVE":"Employee was switching seats to go back to the feeder, twisted right knee and said they heard a loud popping sound.","sourceDate":"2026-02-26"},{"SOURCE_ROW_NUMBER":"106985","DOCUMENT_NO":"220260620026","ACCIDENT_DT":"02/14/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in wielding or throwing objects","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"77","NARRATIVE":"Employee was shoveling dust out onto the #5 conveyor belt. At that time the employee stated that they felt their left bicep pull.","sourceDate":"2026-02-14"},{"SOURCE_ROW_NUMBER":"274970","DOCUMENT_NO":"220260270009","ACCIDENT_DT":"01/26/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"Employee was using a 4LB hammer to brad a splice when a piece of the hammer broke off and went into the employee's right forearm","sourceDate":"2026-01-26"},{"SOURCE_ROW_NUMBER":"236391","DOCUMENT_NO":"220260090020","ACCIDENT_DT":"12/26/2025","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"employee went to step down off the platform to tram the bolter and misplaced EE's footing and all EE's weight went on EE's left ankle","sourceDate":"2025-12-26"},{"SOURCE_ROW_NUMBER":"244989","DOCUMENT_NO":"220253230006","ACCIDENT_DT":"11/13/2025","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Injured employee was placing expanded metal guarding on the head drive when the metal slid around and caught EE's left pinky finger against the rib.","sourceDate":"2025-11-13"},{"SOURCE_ROW_NUMBER":"115701","DOCUMENT_NO":"220253230007","ACCIDENT_DT":"11/13/2025","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","NARRATIVE":"Injured Employee was putting in belt structure and smashed right index finger.","sourceDate":"2025-11-13"},{"SOURCE_ROW_NUMBER":"81496","DOCUMENT_NO":"220253230038","ACCIDENT_DT":"11/09/2025","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Fall from ladders","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"180","NARRATIVE":"Employee was plastering stopping when the employees foot slipped of the ladder causing the employee to fall and roll right ankle.","sourceDate":"2025-11-09"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2026-10-06","lastDate":"2026-10-06","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":1423,"firstDate":"2022-02-24","lastDate":"2026-09-01","metrics":{"ss":385,"delinquent":1380,"recentRows":1423,"paidPenalty":371164.36,"proposedPenalty":5117481,"currentAssessment":4844666.8},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2998618","VIOLATION_NO":"5180241","ISSUE_DT":"09/01/2026","CFR_STANDARD_CD":"50.20(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"165.00","CURRENT_ASSESSMENT_AMT":"165.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"2998617","VIOLATION_NO":"5180238","ISSUE_DT":"09/01/2026","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2503.00","CURRENT_ASSESSMENT_AMT":"2503.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"2998616","VIOLATION_NO":"5180237","ISSUE_DT":"09/01/2026","CFR_STANDARD_CD":"75.1403-6(b)(2)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"549.00","CURRENT_ASSESSMENT_AMT":"549.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"2998615","VIOLATION_NO":"5180217","ISSUE_DT":"08/06/2026","CFR_STANDARD_CD":"75.1714-3(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-06"},{"SOURCE_ROW_NUMBER":"2998614","VIOLATION_NO":"5180216","ISSUE_DT":"08/06/2026","CFR_STANDARD_CD":"75.1714-3(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-06"},{"SOURCE_ROW_NUMBER":"2998613","VIOLATION_NO":"5180215","ISSUE_DT":"08/06/2026","CFR_STANDARD_CD":"75.1100-2(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-06"},{"SOURCE_ROW_NUMBER":"2938208","VIOLATION_NO":"5092558","ISSUE_DT":"08/04/2026","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"11450.00","CURRENT_ASSESSMENT_AMT":"11450.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-04"},{"SOURCE_ROW_NUMBER":"2938207","VIOLATION_NO":"5092557","ISSUE_DT":"08/04/2026","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"9757.00","CURRENT_ASSESSMENT_AMT":"9757.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-04"},{"SOURCE_ROW_NUMBER":"2998603","VIOLATION_NO":"5180202","ISSUE_DT":"07/27/2026","CFR_STANDARD_CD":"75.402","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-07-27"},{"SOURCE_ROW_NUMBER":"2998602","VIOLATION_NO":"5180201","ISSUE_DT":"07/27/2026","CFR_STANDARD_CD":"75.402","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-07-27"},{"SOURCE_ROW_NUMBER":"2998601","VIOLATION_NO":"5180199","ISSUE_DT":"07/21/2026","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"267.00","CURRENT_ASSESSMENT_AMT":"267.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-07-21"},{"SOURCE_ROW_NUMBER":"2998600","VIOLATION_NO":"5180198","ISSUE_DT":"07/21/2026","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"267.00","CURRENT_ASSESSMENT_AMT":"267.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-07-21"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":558,"firstDate":"2023-06-13","lastDate":"2025-11-19","metrics":{"appeals":0,"decisions":555,"recentRows":555,"decisionPenalty":484439.8,"originalPenalty":757911},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"460125","VIOLATION_NO":"5090176","DOCKET_NO":"WEVA 2025-0502","DECISION_DT":"11/19/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1037.00","DECISION_PENALTY_AMT":"1037.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2025-11-19"},{"SOURCE_ROW_NUMBER":"459456","VIOLATION_NO":"9839745","DOCKET_NO":"WEVA 2025-0476","DECISION_DT":"11/19/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"9757.00","DECISION_PENALTY_AMT":"4757.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2025-11-19"},{"SOURCE_ROW_NUMBER":"458879","VIOLATION_NO":"5090178","DOCKET_NO":"WEVA 2025-0502","DECISION_DT":"11/19/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4047.00","DECISION_PENALTY_AMT":"2433.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2025-11-19"},{"SOURCE_ROW_NUMBER":"458851","VIOLATION_NO":"5091123","DOCKET_NO":"WEVA 2025-0502","DECISION_DT":"11/19/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"151.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2025-11-19"},{"SOURCE_ROW_NUMBER":"458392","VIOLATION_NO":"9839049","DOCKET_NO":"WEVA 2025-0476","DECISION_DT":"11/19/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"26139.00","DECISION_PENALTY_AMT":"14397.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2025-11-19"},{"SOURCE_ROW_NUMBER":"166837","VIOLATION_NO":"5090175","DOCKET_NO":"WEVA 2025-0502","DECISION_DT":"11/19/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"883.00","DECISION_PENALTY_AMT":"883.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2025-11-19"},{"SOURCE_ROW_NUMBER":"166661","VIOLATION_NO":"5090177","DOCKET_NO":"WEVA 2025-0502","DECISION_DT":"11/19/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"6037.00","DECISION_PENALTY_AMT":"2181.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2025-11-19"},{"SOURCE_ROW_NUMBER":"166259","VIOLATION_NO":"9839885","DOCKET_NO":"WEVA 2025-0476","DECISION_DT":"11/19/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"245.00","DECISION_PENALTY_AMT":"245.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2025-11-19"},{"SOURCE_ROW_NUMBER":"166258","VIOLATION_NO":"5090823","DOCKET_NO":"WEVA 2025-0476","DECISION_DT":"11/19/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"245.00","DECISION_PENALTY_AMT":"245.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2025-11-19"},{"SOURCE_ROW_NUMBER":"166257","VIOLATION_NO":"5090822","DOCKET_NO":"WEVA 2025-0476","DECISION_DT":"11/19/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"818.00","DECISION_PENALTY_AMT":"818.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2025-11-19"},{"SOURCE_ROW_NUMBER":"458333","VIOLATION_NO":"5090801","DOCKET_NO":"WEVA 2025-0370","DECISION_DT":"07/21/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"366.00","DECISION_PENALTY_AMT":"366.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2025-07-21"},{"SOURCE_ROW_NUMBER":"458332","VIOLATION_NO":"5090702","DOCKET_NO":"WEVA 2025-0370","DECISION_DT":"07/21/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"14557.00","DECISION_PENALTY_AMT":"6057.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2025-07-21"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":581,"firstDate":"2022-05-04","lastDate":"2026-06-23","metrics":{"recentRows":581,"cpdmSamples":450,"voidSamples":168,"validSamples":413,"maxConcentration":18.657,"concentrationTotal":200.274},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1576922","CASS_NUM":"58593405","SMP_TAKEN_DT":"6/23/2026","CONC":".056","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"DISPATCHER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-06-23"},{"SOURCE_ROW_NUMBER":"1510862","CASS_NUM":"58593401","SMP_TAKEN_DT":"6/23/2026","CONC":".13","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"FIRE BOSS PRE-SHIFT EXAMINER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-06-23"},{"SOURCE_ROW_NUMBER":"1437730","CASS_NUM":"58593419","SMP_TAKEN_DT":"6/23/2026","CONC":".088","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-06-23"},{"SOURCE_ROW_NUMBER":"1404377","CASS_NUM":"58593394","SMP_TAKEN_DT":"6/23/2026","CONC":".043","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-06-23"},{"SOURCE_ROW_NUMBER":"1142174","CASS_NUM":"58593373","SMP_TAKEN_DT":"6/23/2026","CONC":".019","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-06-23"},{"SOURCE_ROW_NUMBER":"1052946","CASS_NUM":"58593361","SMP_TAKEN_DT":"6/23/2026","CONC":".189","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-06-23"},{"SOURCE_ROW_NUMBER":"760888","CASS_NUM":"58593400","SMP_TAKEN_DT":"6/23/2026","CONC":".214","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-06-23"},{"SOURCE_ROW_NUMBER":"677692","CASS_NUM":"58593379","SMP_TAKEN_DT":"6/23/2026","CONC":".178","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-06-23"},{"SOURCE_ROW_NUMBER":"535194","CASS_NUM":"58593390","SMP_TAKEN_DT":"6/23/2026","CONC":".077","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BELT CLEANER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-06-23"},{"SOURCE_ROW_NUMBER":"352953","CASS_NUM":"58593333","SMP_TAKEN_DT":"6/23/2026","CONC":".099","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-06-23"},{"SOURCE_ROW_NUMBER":"129533","CASS_NUM":"58593425","SMP_TAKEN_DT":"6/23/2026","CONC":".187","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-06-23"},{"SOURCE_ROW_NUMBER":"117191","CASS_NUM":"58593411","SMP_TAKEN_DT":"6/23/2026","CONC":".082","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ELECTRICIAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-06-23"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":80,"firstDate":"2021-06-17","lastDate":"2026-08-04","metrics":{"linkedIssuances":80},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":558,"firstDate":"2022-02-24","lastDate":"2025-06-30","metrics":{"decisions":555,"ssChanged":14,"recentRows":558,"decisionPenalty":484439.8,"proposedPenalty":1029858},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"55599","CITATION_NO":"5090178","CITATION_ISSUE_DT":"06/30/2025","DOCKET_NO":"WEVA 2025-0502","DECISION_DT":"11/19/2025","CFR_STANDARD_CODE":"75.1732(b)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"4047.00","DECISION_PENALTY_AMT":"2433.00","sourceDate":"2025-06-30"},{"SOURCE_ROW_NUMBER":"280776","CITATION_NO":"5090177","CITATION_ISSUE_DT":"06/25/2025","DOCKET_NO":"WEVA 2025-0502","DECISION_DT":"11/19/2025","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"6037.00","DECISION_PENALTY_AMT":"2181.00","sourceDate":"2025-06-25"},{"SOURCE_ROW_NUMBER":"280138","CITATION_NO":"5090175","CITATION_ISSUE_DT":"06/25/2025","DOCKET_NO":"WEVA 2025-0502","DECISION_DT":"11/19/2025","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"883.00","DECISION_PENALTY_AMT":"883.00","sourceDate":"2025-06-25"},{"SOURCE_ROW_NUMBER":"166962","CITATION_NO":"5090176","CITATION_ISSUE_DT":"06/25/2025","DOCKET_NO":"WEVA 2025-0502","DECISION_DT":"11/19/2025","CFR_STANDARD_CODE":"75.1100-3","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1037.00","DECISION_PENALTY_AMT":"1037.00","sourceDate":"2025-06-25"},{"SOURCE_ROW_NUMBER":"336751","CITATION_NO":"5091123","CITATION_ISSUE_DT":"06/11/2025","DOCKET_NO":"WEVA 2025-0502","DECISION_DT":"11/19/2025","CFR_STANDARD_CODE":"75.1202-1(b)(3)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"151.00","sourceDate":"2025-06-11"},{"SOURCE_ROW_NUMBER":"391764","CITATION_NO":"5090823","CITATION_ISSUE_DT":"05/30/2025","DOCKET_NO":"WEVA 2025-0476","DECISION_DT":"11/19/2025","CFR_STANDARD_CODE":"75.1600-2(e)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"245.00","DECISION_PENALTY_AMT":"245.00","sourceDate":"2025-05-30"},{"SOURCE_ROW_NUMBER":"110944","CITATION_NO":"5090822","CITATION_ISSUE_DT":"05/30/2025","DOCKET_NO":"WEVA 2025-0476","DECISION_DT":"11/19/2025","CFR_STANDARD_CODE":"75.601","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"818.00","DECISION_PENALTY_AMT":"818.00","sourceDate":"2025-05-30"},{"SOURCE_ROW_NUMBER":"224158","CITATION_NO":"9839885","CITATION_ISSUE_DT":"05/21/2025","DOCKET_NO":"WEVA 2025-0476","DECISION_DT":"11/19/2025","CFR_STANDARD_CODE":"77.505","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"245.00","DECISION_PENALTY_AMT":"245.00","sourceDate":"2025-05-21"},{"SOURCE_ROW_NUMBER":"111252","CITATION_NO":"9839745","CITATION_ISSUE_DT":"04/23/2025","DOCKET_NO":"WEVA 2025-0476","DECISION_DT":"11/19/2025","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"9757.00","DECISION_PENALTY_AMT":"4757.00","sourceDate":"2025-04-23"},{"SOURCE_ROW_NUMBER":"51838","CITATION_NO":"9839049","CITATION_ISSUE_DT":"04/22/2025","DOCKET_NO":"WEVA 2025-0476","DECISION_DT":"11/19/2025","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"26139.00","DECISION_PENALTY_AMT":"14397.00","sourceDate":"2025-04-22"},{"SOURCE_ROW_NUMBER":"111832","CITATION_NO":"9839844","CITATION_ISSUE_DT":"04/07/2025","DOCKET_NO":"WEVA 2025-0370","DECISION_DT":"07/21/2025","CFR_STANDARD_CODE":"50.11(b)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"165.00","DECISION_PENALTY_AMT":"165.00","sourceDate":"2025-04-07"},{"SOURCE_ROW_NUMBER":"447995","CITATION_NO":"9839836","CITATION_ISSUE_DT":"04/04/2025","DOCKET_NO":"WEVA 2025-0370","DECISION_DT":"07/21/2025","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"4749.00","DECISION_PENALTY_AMT":"4749.00","sourceDate":"2025-04-04"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":378,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":88,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":8,"firstDate":"2013-03-13","lastDate":"2021-03-11","metrics":{"recentRows":6,"currentOperatorTenures":6,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":170,"firstDate":"2021-03-05","lastDate":"2026-10-07","metrics":{"inspectors":345,"recentRows":170,"onSiteHours":3737,"inspectionHours":5172,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"406574","EVENT_NO":"F020DCF","INSPECTION_BEGIN_DT":"10/07/2026","INSPECTION_END_DT":"10/07/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"746808","EVENT_NO":"F021FC1","INSPECTION_BEGIN_DT":"10/06/2026","INSPECTION_END_DT":"10/06/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"0","SUM_TOTAL_INSP_HOURS":"0","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"464524","EVENT_NO":"F021FC0","INSPECTION_BEGIN_DT":"09/30/2026","INSPECTION_END_DT":"09/30/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.5","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2026-09-30"},{"SOURCE_ROW_NUMBER":"985404","EVENT_NO":"F007CE8","INSPECTION_BEGIN_DT":"09/22/2026","INSPECTION_END_DT":"09/23/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"28.75","SUM_TOTAL_ON_SITE_HOURS":"17.25","sourceDate":"2026-09-22"},{"SOURCE_ROW_NUMBER":"938067","EVENT_NO":"F03FD94","INSPECTION_BEGIN_DT":"09/17/2026","INSPECTION_END_DT":"09/17/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2026-09-17"},{"SOURCE_ROW_NUMBER":"266079","EVENT_NO":"F03FD93","INSPECTION_BEGIN_DT":"09/15/2026","INSPECTION_END_DT":"09/15/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-09-15"},{"SOURCE_ROW_NUMBER":"45203","EVENT_NO":"F02104C","INSPECTION_BEGIN_DT":"09/11/2026","INSPECTION_END_DT":"09/15/2026","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"19.75","SUM_TOTAL_ON_SITE_HOURS":"12.5","sourceDate":"2026-09-11"},{"SOURCE_ROW_NUMBER":"766229","EVENT_NO":"F0150BF","INSPECTION_BEGIN_DT":"09/10/2026","INSPECTION_END_DT":"09/11/2026","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"22.75","SUM_TOTAL_ON_SITE_HOURS":"16.25","sourceDate":"2026-09-10"},{"SOURCE_ROW_NUMBER":"435318","EVENT_NO":"F0150BE","INSPECTION_BEGIN_DT":"09/10/2026","INSPECTION_END_DT":"09/10/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"9.75","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-09-10"},{"SOURCE_ROW_NUMBER":"590507","EVENT_NO":"F02104A","INSPECTION_BEGIN_DT":"09/03/2026","INSPECTION_END_DT":"09/04/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11.25","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-09-03"},{"SOURCE_ROW_NUMBER":"1082878","EVENT_NO":"F021049","INSPECTION_BEGIN_DT":"09/01/2026","INSPECTION_END_DT":"09/02/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14.75","SUM_TOTAL_ON_SITE_HOURS":"11.75","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"1125189","EVENT_NO":"7034159","INSPECTION_BEGIN_DT":"08/28/2026","INSPECTION_END_DT":"08/28/2026","ACTIVITY_CODE":"E03","ACTIVITY":"103 (g) Written Notification Hazard Complaint Inspectio","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2026-08-28"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":58,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2026-Q2":{"hours":30772,"employees":67,"production":36716},"2026-Q1":{"hours":20920,"employees":69,"production":22558},"2025-Q4":{"hours":21313,"employees":61,"production":56426},"2025-Q3":{"hours":30435,"employees":61,"production":52984},"2025-Q2":{"hours":20058,"employees":42,"production":8630},"2025-Q1":{"hours":28400,"employees":51,"production":21937},"2024-Q4":{"hours":27893,"employees":53,"production":17289},"2024-Q3":{"hours":15826,"employees":36,"production":15878},"2024-Q2":{"hours":17528,"employees":40,"production":4302},"2024-Q1":{"hours":25320,"employees":36,"production":49658},"2023-Q4":{"hours":27495,"employees":51,"production":63792},"2023-Q3":{"hours":29023,"employees":73,"production":61005}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":10,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2022":{"hours":75379,"employees":57,"production":207106},"2023":{"hours":104693,"employees":60,"production":304390},"2024":{"hours":86567,"employees":41,"production":87127},"2025":{"hours":100206,"employees":54,"production":139977},"2026":{"hours":51692,"employees":68,"production":59274}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":33,"firstDate":"2022-12-06","lastDate":"2026-06-23","metrics":{"recentRows":33,"doseOver100":2,"actDoseTotal":1323,"pelDoseTotal":906},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"267988","EVENT_NO":"F01509A","SURVEY_DATE":"06/23/2026","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"28","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2026-06-23"},{"SOURCE_ROW_NUMBER":"267987","EVENT_NO":"F01509A","SURVEY_DATE":"06/23/2026","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"84","PEL_DOSE_90":"65","SURVEY_TYPE":"I","sourceDate":"2026-06-23"},{"SOURCE_ROW_NUMBER":"267986","EVENT_NO":"F01509A","SURVEY_DATE":"06/23/2026","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"49","PEL_DOSE_90":"32","SURVEY_TYPE":"I","sourceDate":"2026-06-23"},{"SOURCE_ROW_NUMBER":"267985","EVENT_NO":"F01509A","SURVEY_DATE":"06/23/2026","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"30","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2026-06-23"},{"SOURCE_ROW_NUMBER":"267984","EVENT_NO":"F01509A","SURVEY_DATE":"06/23/2026","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"77","PEL_DOSE_90":"65","SURVEY_TYPE":"I","sourceDate":"2026-06-23"},{"SOURCE_ROW_NUMBER":"267983","EVENT_NO":"F01509A","SURVEY_DATE":"06/23/2026","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","ACT_DOSE_85":"35","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2026-06-23"},{"SOURCE_ROW_NUMBER":"267982","EVENT_NO":"F01509A","SURVEY_DATE":"06/23/2026","OCCUPATION_CD_DESC":"FIRE BOSS PRE-SHIFT EXAMINER","MACHINE_CD":"40","ACT_DOSE_85":"15","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2026-06-23"},{"SOURCE_ROW_NUMBER":"267981","EVENT_NO":"F010C56","SURVEY_DATE":"10/29/2025","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"20","ACT_DOSE_85":"23","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2025-10-29"},{"SOURCE_ROW_NUMBER":"267980","EVENT_NO":"F010C56","SURVEY_DATE":"10/29/2025","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","ACT_DOSE_85":"28","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2025-10-29"},{"SOURCE_ROW_NUMBER":"267979","EVENT_NO":"F010C56","SURVEY_DATE":"10/29/2025","OCCUPATION_CD_DESC":"FIRE BOSS PRE-SHIFT EXAMINER","MACHINE_CD":"20","ACT_DOSE_85":"17","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2025-10-29"},{"SOURCE_ROW_NUMBER":"267978","EVENT_NO":"F010C56","SURVEY_DATE":"10/29/2025","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"20","ACT_DOSE_85":"107","PEL_DOSE_90":"76","SURVEY_TYPE":"I","sourceDate":"2025-10-29"},{"SOURCE_ROW_NUMBER":"267977","EVENT_NO":"F010C56","SURVEY_DATE":"10/29/2025","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"20","ACT_DOSE_85":"75","PEL_DOSE_90":"33","SURVEY_TYPE":"I","sourceDate":"2025-10-29"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":40,"firstDate":"2022-07-21","lastDate":"2026-06-23","metrics":{"recentRows":40,"voidSamples":0,"maxQuartzPct":8.5,"validSamples":40,"quartzPctTotal":118.2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"98153","CASSETTE_NO":"58593379","SAMPLE_DT":"06/23/2026","QUARTZ_PCT":"02.9","QUARTZ_MICROGRAMS":"5","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-06-23"},{"SOURCE_ROW_NUMBER":"18552","CASSETTE_NO":"58593425","SAMPLE_DT":"06/23/2026","QUARTZ_PCT":"05.4","QUARTZ_MICROGRAMS":"10","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-06-23"},{"SOURCE_ROW_NUMBER":"73173","CASSETTE_NO":"58574350","SAMPLE_DT":"02/05/2026","QUARTZ_PCT":"02.0","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-02-05"},{"SOURCE_ROW_NUMBER":"71641","CASSETTE_NO":"58574349","SAMPLE_DT":"02/05/2026","QUARTZ_PCT":"03.5","QUARTZ_MICROGRAMS":"18","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-02-05"},{"SOURCE_ROW_NUMBER":"23137","CASSETTE_NO":"58574356","SAMPLE_DT":"02/05/2026","QUARTZ_PCT":"02.2","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-02-05"},{"SOURCE_ROW_NUMBER":"120252","CASSETTE_NO":"58568106","SAMPLE_DT":"10/29/2025","QUARTZ_MICROGRAMS":"0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-10-29"},{"SOURCE_ROW_NUMBER":"84934","CASSETTE_NO":"58568351","SAMPLE_DT":"10/28/2025","QUARTZ_MICROGRAMS":"0","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-10-28"},{"SOURCE_ROW_NUMBER":"68665","CASSETTE_NO":"58568356","SAMPLE_DT":"10/28/2025","QUARTZ_MICROGRAMS":"0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-10-28"},{"SOURCE_ROW_NUMBER":"12939","CASSETTE_NO":"58568315","SAMPLE_DT":"10/28/2025","QUARTZ_PCT":"01.9","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-10-28"},{"SOURCE_ROW_NUMBER":"38445","CASSETTE_NO":"58568914","SAMPLE_DT":"08/26/2025","QUARTZ_PCT":"02.4","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-08-26"},{"SOURCE_ROW_NUMBER":"12930","CASSETTE_NO":"58568884","SAMPLE_DT":"08/26/2025","QUARTZ_MICROGRAMS":"0","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-08-26"},{"SOURCE_ROW_NUMBER":"114749","CASSETTE_NO":"58501118","SAMPLE_DT":"03/11/2025","QUARTZ_MICROGRAMS":"0","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-03-11"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":1492,"firstDate":"2021-03-05","lastDate":"2026-09-30","metrics":{"ss":396,"amountDue":4844666.8,"contested":0,"amountPaid":371164.36,"recentRows":1492,"section104d":83,"unterminated":19,"proposedPenalty":5117481},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2970318","VIOLATION_NO":"5092758","VIOLATION_ISSUE_DT":"09/30/2026","SIG_SUB":"Y","PART_SECTION":"75.1732(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-09-30"},{"SOURCE_ROW_NUMBER":"2970317","VIOLATION_NO":"5092757","VIOLATION_ISSUE_DT":"09/30/2026","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-09-30"},{"SOURCE_ROW_NUMBER":"2970309","VIOLATION_NO":"5028621","VIOLATION_ISSUE_DT":"09/22/2026","SIG_SUB":"N","PART_SECTION":"75.1100-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/22/2026","CONTESTED_IND":"N","sourceDate":"2026-09-22"},{"SOURCE_ROW_NUMBER":"2970308","VIOLATION_NO":"5028620","VIOLATION_ISSUE_DT":"09/22/2026","SIG_SUB":"N","PART_SECTION":"75.1106-3(a)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/22/2026","CONTESTED_IND":"N","sourceDate":"2026-09-22"},{"SOURCE_ROW_NUMBER":"2970307","VIOLATION_NO":"5028619","VIOLATION_ISSUE_DT":"09/22/2026","SIG_SUB":"N","PART_SECTION":"75.1600-2(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/23/2026","CONTESTED_IND":"N","sourceDate":"2026-09-22"},{"SOURCE_ROW_NUMBER":"2970306","VIOLATION_NO":"5028618","VIOLATION_ISSUE_DT":"09/22/2026","SIG_SUB":"N","PART_SECTION":"75.1100-2(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/23/2026","CONTESTED_IND":"N","sourceDate":"2026-09-22"},{"SOURCE_ROW_NUMBER":"2970305","VIOLATION_NO":"5028617","VIOLATION_ISSUE_DT":"09/22/2026","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/23/2026","CONTESTED_IND":"N","sourceDate":"2026-09-22"},{"SOURCE_ROW_NUMBER":"2970304","VIOLATION_NO":"5028616","VIOLATION_ISSUE_DT":"09/22/2026","SIG_SUB":"Y","PART_SECTION":"75.1722(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/23/2026","CONTESTED_IND":"N","sourceDate":"2026-09-22"},{"SOURCE_ROW_NUMBER":"2970303","VIOLATION_NO":"5028615","VIOLATION_ISSUE_DT":"09/22/2026","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/23/2026","CONTESTED_IND":"N","sourceDate":"2026-09-22"},{"SOURCE_ROW_NUMBER":"2970302","VIOLATION_NO":"5028614","VIOLATION_ISSUE_DT":"09/22/2026","SIG_SUB":"N","PART_SECTION":"75.1505(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/22/2026","CONTESTED_IND":"N","sourceDate":"2026-09-22"},{"SOURCE_ROW_NUMBER":"2970300","VIOLATION_NO":"5180248","VIOLATION_ISSUE_DT":"09/14/2026","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/15/2026","CONTESTED_IND":"N","sourceDate":"2026-09-14"},{"SOURCE_ROW_NUMBER":"2970299","VIOLATION_NO":"5180247","VIOLATION_ISSUE_DT":"09/14/2026","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/23/2026","CONTESTED_IND":"N","sourceDate":"2026-09-14"}]}],"safety":{"href":"/api/v1/mines/4609474/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609474/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":{"averageEmployees":43,"companyType":"Operating Subsidiary","components":[{"averageEmployees":43,"laborHours":87071,"mineType":"Underground","productionTons":87127}],"county":"Wyoming","laborHours":87071,"mineName":"Belcher Branch","mineType":"Underground","mshaId":"4609474","operatingAddress":"302 South Jefferson, Roanoke, VA 24011","operatingCompany":"Frontier Coal Company","operationType":"Mine only","productionTons":87127,"reportedRows":1,"sourceUrl":"https://www.eia.gov/coal/data/public/xls/coalpublic2024.xlsx","state":"West Virginia (Southern)","status":"Active","supplyRegion":"Appalachia Central","union":"","year":2024},"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1732","heading":"Proximity detection systems.","id":"75.1732","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1732","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"Operators must install proximity detection systems on certain mobile machines.\n\n(a) Machines covered. Operators must equip continuous mining machines, except full-face continuous mining machines, with proximity detection systems by the following dates. For proximity detection systems with miner-wearable components, the mine operator must provide a miner-wearable component to be worn by each miner on the working section by the following dates.\n\n(1) Continuous mining machines manufactured after March 16, 2015 must meet the requirements in this section no later than November 16, 2015. These machines must meet the requirements in this section when placed in service with a proximity detection system.\n\n(2) Continuous mining machines manufactured and equipped with a proximity detection system on or before March 16, 2015 must meet the requirements in this section no later than September 16, 2016.\n\n(3) Continuous mining machines manufactured and not equipped with a proximity detection system on or before March 16, 2015 must meet the requirements in this section no later than March 16, 2018. These machines must meet the requirements in this section when placed in service with a proximity detection system.\n\n(b) Requirements for a proximity detection system. A proximity detection system includes machine-mounted components and miner-wearable components. The system must:\n\n(1) Cause a machine, which is tramming from place-to-place or repositioning, to stop before contacting a miner except for a miner who is in the on-board operator's compartment;\n\n(2) Provide an audible and visual warning signal on the miner-wearable component and a visual warning signal on the machine that alert miners before the system causes a machine to stop. These warning signals must be distinguishable from other signals;\n\n(3) Provide a visual signal on the machine that indicates the machine-mounted components are functioning properly;\n\n(4) Prevent movement of the machine if any machine-mounted component of the system is not functioning properly. However, a system with any machine-mounted component that is not functioning properly may allow machine movement if it provides an audible or visual warning signal, distinguishable from other signals, during movement. Such movement is permitted only for purposes of relocating the machine from an unsafe location for repair;\n\n(5) Be installed to prevent interference that adversely affects performance of any electrical system; and\n\n(6) Be installed and maintained in proper operating condition by a person trained in the installation and maintenance of the system.\n\n(c) Proximity detection system checks. Operators must:\n\n(1) Designate a person who must perform a check of machine-mounted components of the proximity detection system to verify that components are intact, that the system is functioning properly, and take action to correct defects—\n\n(i) At the beginning of each shift when the machine is to be used; or\n\n(ii) Immediately prior to the time the machine is to be operated if not in use at the beginning of a shift; or\n\n(iii) Within 1 hour of a shift change if the shift change occurs without an interruption in production.\n\n(2) Check for proper operation of miner-wearable components at the beginning of each shift that the components are to be used and correct defects before the components are used.\n\n(d) Certifications and records. The operator must make and retain certifications and records as follows:\n\n(1) At the completion of the check of machine-mounted components required under paragraph (c)(1) of this section, a certified person under § 75.100 must certify by initials, date, and time that the check was conducted. Defects found as a result of the check, including corrective actions and dates of corrective actions, must be recorded before the end of the shift;\n\n(2) Make a record of the defects found as a result of the check of miner-wearable components required under paragraph (c)(2) of this section, including corrective actions and dates of corrective actions;\n\n(3) Make a record of the persons trained in the installation and maintenance of proximity detection systems required under paragraph (b)(6) of this section;\n\n(4) Maintain records in a secure book or electronically in a secure computer system not susceptible to alteration; and\n\n(5) Retain records for at least one year and make them available for inspection by authorized representatives of the Secretary and representatives of miners.\n\n[80 FR 2202, Jan. 15, 2015]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-3","heading":"Condition and examination of firefighting equipment.","id":"75.1100-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"All firefighting equipment shall be maintained in a usable and operative condition. Chemical extinguishers shall be examined every 6 months and the date of the examination shall be written on a permanent tag attached to the extinguisher.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1106-3","heading":"Storage of liquefied and nonliquefied compressed gas cylinders; requirements.","id":"75.1106-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1106-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Liquefied and nonliquefied compressed gas cylinders stored in an underground coal mine shall be:\n\n(1) Clearly marked and identified as to their contents in accordance with Department of Transportation regulations.\n\n(2) Placed securely in storage areas designated by the operator for such purpose, and where the height of the coalbed permits, in an upright position, preferably in specially designated racks, or otherwise secured against being accidently tipped over.\n\n(3) Protected against damage from falling material, contact with power lines and energized electrical equipment, heat from welding, cutting or soldering, and exposure to flammable liquids.\n\n(b) Liquefied and nonliquefied compressed gas cylinders shall not be stored or left unattended in any area inby the last open crosscut of an underground coal mine.\n\n(c) When not in use, the valves of all liquefied and nonliquefied compressed gas cylinders shall be in the closed position, and all hoses shall be removed from the cylinder.\n\n[36 FR 22061, Nov. 19, 1971]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1600-2","heading":"Communication facilities; working sections; installation and maintenance requirements; audible or visual alarms.","id":"75.1600-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-Q/section-75.1600-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Communications","text":"(a) Telephones or equivalent two-way communication facilities provided at each working section shall be located not more than 500 feet outby the last open crosscut and not more than 800 feet from the farthest point of penetration of the working places on such section.\n\n(b) The incoming communication signal shall activate an audible alarm, distinguishable from the surrounding noise level, or a visual alarm that can be seen by a miner regularly employed on the working section.\n\n(c) If a communication system other than telephones is used and its operation depends entirely upon power from the mine electric system, means shall be provided to permit continued communication in the event the mine electric power fails or is cut off; provided, however, that where trolley phones and telephones are both used, an alternate source of power for the trolley phone system is not required.\n\n(d) Trolley phones connected to the trolley wire shall be grounded in accordance with Subpart H of this part.\n\n(e) Telephones or equivalent two-way communication facilities shall be maintained in good operating condition at all times. In the event of any failure in the system that results in loss of communication, repairs shall be started immediately, and the system restored to operating condition as soon as possible.\n\n[38 FR 29999, Oct. 31, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1722","heading":"Mechanical equipment guards.","id":"75.1722","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1722","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1505","heading":"Escapeway maps.","id":"75.1505","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-P/section-75.1505","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"P","subpartHeading":"Subpart P—Mine Emergencies","text":"(a) Content and accessibility. An escapeway map shall show the designated escapeways from the working sections or the miners' work stations to the surface or the exits at the bottom of the shaft or slope, refuge alternatives, and SCSR storage locations. The escapeway map shall be posted or readily accessible for all miners—\n\n(1) In each working section;\n\n(2) In each area where mechanized mining equipment is being installed or removed;\n\n(3) At the refuge alternative; and\n\n(4) At a surface location of the mine where miners congregate, such as at the mine bulletin board, bathhouse, or waiting room.\n\n(b) Keeping maps current. All maps shall be kept up-to-date and any change in route of travel, location of doors, location of refuge alternatives, or direction of airflow shall be shown on the maps by the end of the shift on which the change is made.\n\n(c) Informing affected miners. Miners underground on a shift when any such change is made shall be notified immediately of the change and other affected miners shall be informed of the change before entering the underground areas of the mine.\n\n[71 FR 71452, Dec. 8, 2006, as amended at 73 FR 80698, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609474","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}