{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4609420","name":"Ike Fork 5 Block Deep Mine","status":"Abandoned","status_date":"2022-11-15","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Nicholas","nearest_town":"Bickmore","operator_id":"0185933","operator_name":"Straight Arrow Ventures, LLC","controller_id":"0173121","controller_name":"True Flight Ventures LLC; AppleAtcha Land LLC","district":"C04","office":"Summersville WV Field Office","employees":0,"latitude":38.374722,"longitude":-80.989444},"coverage":{"contributingSources":14,"registeredSources":20,"sourceRows":287},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609420","name":"Ike Fork 5 Block Deep Mine"},"operator":{"type":"operator","id":"0185933","name":"Straight Arrow Ventures, LLC"},"controller":{"type":"controller","id":"0173121","name":"True Flight Ventures LLC; AppleAtcha Land LLC"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C05954","name":"Amvest Corporation"},"object":{"type":"mine","id":"4609420","name":"Ike Fork 5 Block Deep Mine"},"validFrom":"2002-08-16","validTo":"2007-07-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609420|C05954|2002-08-16|2007-07-31"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00692","name":"CONSOL Energy Inc"},"object":{"type":"mine","id":"4609420","name":"Ike Fork 5 Block Deep Mine"},"validFrom":"2007-08-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609420|C00692|2007-08-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0050873","name":"Little Eagle Coal Company, L.L.C."},"object":{"type":"mine","id":"4609420","name":"Ike Fork 5 Block Deep Mine"},"validFrom":"2011-05-31","validTo":"2022-11-14","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609420|0050873|2011-05-31|2022-11-14"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00692","name":"CONSOL Energy Inc"},"object":{"type":"operator","id":"0050873","name":"Little Eagle Coal Company, L.L.C."},"validFrom":"2011-05-31","validTo":"2022-11-14","current":false,"derived":true,"evidenceMineId":"4609420","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609420|0050873|2011-05-31|C00692|2007-08-01|49401"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C05954","name":"Amvest Corporation"},"object":{"type":"operator","id":"0050873","name":"Little Eagle Coal Company, L.L.C."},"validFrom":"2011-05-31","validTo":"2007-07-31","current":false,"derived":true,"evidenceMineId":"4609420","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609420|0050873|2011-05-31|C05954|2002-08-16|70407"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0185933","name":"Straight Arrow Ventures, LLC"},"object":{"type":"mine","id":"4609420","name":"Ike Fork 5 Block Deep Mine"},"validFrom":"2022-11-15","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609420|0185933|2022-11-15|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0173121","name":"AppleAtcha Land LLC et al"},"object":{"type":"mine","id":"4609420","name":"Ike Fork 5 Block Deep Mine"},"validFrom":"2022-11-15","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609420|0173121|2022-11-15|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0173121","name":"AppleAtcha Land LLC et al"},"object":{"type":"operator","id":"0185933","name":"Straight Arrow Ventures, LLC"},"validFrom":"2022-11-15","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609420","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609420|0185933|2022-11-15|0173121|2022-11-15|36760"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0173121","name":"True Flight Ventures LLC et al"},"object":{"type":"operator","id":"0185933","name":"Straight Arrow Ventures, LLC"},"validFrom":"2022-11-15","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609420","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609420|0185933|2022-11-15|0173121|2022-11-15|36761"}}],"coverage":{"historyRecords":4,"edgeCount":9,"intervalAnomalies":1,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":1,"firstDate":"2013-07-09","lastDate":"2013-07-09","metrics":{"daysLost":0,"injuries":1,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"154600","DOCUMENT_NO":"220131910004","ACCIDENT_DT":"07/09/2013","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The company was notified 7/9/13 that EE qualified for a occupational pneumoconiosis claim.","sourceDate":"2013-07-09"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2022-11-15","lastDate":"2022-11-15","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":37,"firstDate":"2012-01-26","lastDate":"2012-09-26","metrics":{"ss":9,"delinquent":37,"recentRows":0,"paidPenalty":9604,"proposedPenalty":13285,"currentAssessment":9604},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1828763","VIOLATION_NO":"7224724","ISSUE_DT":"09/26/2012","CFR_STANDARD_CD":"75.1714-4(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-26"},{"SOURCE_ROW_NUMBER":"1828769","VIOLATION_NO":"8154213","ISSUE_DT":"09/06/2012","CFR_STANDARD_CD":"77.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"150.00","CURRENT_ASSESSMENT_AMT":"150.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-06"},{"SOURCE_ROW_NUMBER":"1828768","VIOLATION_NO":"8154212","ISSUE_DT":"09/06/2012","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-06"},{"SOURCE_ROW_NUMBER":"1828766","VIOLATION_NO":"8151564","ISSUE_DT":"09/06/2012","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"308.00","CURRENT_ASSESSMENT_AMT":"277.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-06"},{"SOURCE_ROW_NUMBER":"1828765","VIOLATION_NO":"8151563","ISSUE_DT":"09/06/2012","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-06"},{"SOURCE_ROW_NUMBER":"1828764","VIOLATION_NO":"8151562","ISSUE_DT":"09/06/2012","CFR_STANDARD_CD":"75.1107-4(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-06"},{"SOURCE_ROW_NUMBER":"1828767","VIOLATION_NO":"8154211","ISSUE_DT":"09/05/2012","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"138.00","CURRENT_ASSESSMENT_AMT":"138.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-05"},{"SOURCE_ROW_NUMBER":"1828762","VIOLATION_NO":"7178846","ISSUE_DT":"08/09/2012","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"285.00","CURRENT_ASSESSMENT_AMT":"285.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-08-09"},{"SOURCE_ROW_NUMBER":"1828709","VIOLATION_NO":"8126675","ISSUE_DT":"06/18/2012","CFR_STANDARD_CD":"75.320(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"162.00","CURRENT_ASSESSMENT_AMT":"162.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-06-18"},{"SOURCE_ROW_NUMBER":"1828708","VIOLATION_NO":"8126674","ISSUE_DT":"06/18/2012","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"138.00","CURRENT_ASSESSMENT_AMT":"138.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-06-18"},{"SOURCE_ROW_NUMBER":"1828707","VIOLATION_NO":"8126673","ISSUE_DT":"06/18/2012","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"138.00","CURRENT_ASSESSMENT_AMT":"138.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-06-18"},{"SOURCE_ROW_NUMBER":"1828713","VIOLATION_NO":"8139305","ISSUE_DT":"06/14/2012","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-06-14"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":2,"firstDate":"2013-03-29","lastDate":"2014-06-24","metrics":{"appeals":0,"decisions":2,"recentRows":0,"decisionPenalty":3927,"originalPenalty":7608},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"92607","VIOLATION_NO":"8151564","DOCKET_NO":"WEVA 2013-116","DECISION_DT":"06/24/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"308.00","DECISION_PENALTY_AMT":"277.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2014-06-24"},{"SOURCE_ROW_NUMBER":"331074","VIOLATION_NO":"8145107","DOCKET_NO":"WEVA 2012-1627","DECISION_DT":"03/29/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"7300.00","DECISION_PENALTY_AMT":"3650.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2013-03-29"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":101,"firstDate":"2012-03-12","lastDate":"2012-10-01","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":27,"validSamples":74,"maxConcentration":4.602,"concentrationTotal":50.244},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1356612","CASS_NUM":"51087376","SMP_TAKEN_DT":"10/1/2012","CONC":".566","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-10-01"},{"SOURCE_ROW_NUMBER":"478958","CASS_NUM":"51087467","SMP_TAKEN_DT":"10/1/2012","CONC":".151","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-10-01"},{"SOURCE_ROW_NUMBER":"928129","CASS_NUM":"51087399","SMP_TAKEN_DT":"9/28/2012","CONC":"1.099","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-28"},{"SOURCE_ROW_NUMBER":"88558","CASS_NUM":"51087452","SMP_TAKEN_DT":"9/28/2012","CONC":".113","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-28"},{"SOURCE_ROW_NUMBER":"1471680","CASS_NUM":"51087415","SMP_TAKEN_DT":"9/27/2012","CONC":".293","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-27"},{"SOURCE_ROW_NUMBER":"81228","CASS_NUM":"51087422","SMP_TAKEN_DT":"9/27/2012","CONC":".186","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-27"},{"SOURCE_ROW_NUMBER":"839895","CASS_NUM":"51087411","SMP_TAKEN_DT":"9/26/2012","CONC":".162","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-26"},{"SOURCE_ROW_NUMBER":"104921","CASS_NUM":"51087449","SMP_TAKEN_DT":"9/26/2012","CONC":".148","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-26"},{"SOURCE_ROW_NUMBER":"1611722","CASS_NUM":"51087443","SMP_TAKEN_DT":"9/25/2012","CONC":".12","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-25"},{"SOURCE_ROW_NUMBER":"1198298","CASS_NUM":"51087454","SMP_TAKEN_DT":"9/25/2012","CONC":".152","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-25"},{"SOURCE_ROW_NUMBER":"1635248","CASS_NUM":"51087432","SMP_TAKEN_DT":"9/24/2012","CONC":".343","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-24"},{"SOURCE_ROW_NUMBER":"240288","CASS_NUM":"51087468","SMP_TAKEN_DT":"9/24/2012","CONC":".068","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-24"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":1,"firstDate":"2012-03-30","lastDate":"2012-03-30","metrics":{"linkedIssuances":1},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":2,"firstDate":"2012-01-26","lastDate":"2012-09-06","metrics":{"decisions":2,"ssChanged":0,"recentRows":0,"decisionPenalty":3927,"proposedPenalty":7608},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"198578","CITATION_NO":"8151564","CITATION_ISSUE_DT":"09/06/2012","DOCKET_NO":"WEVA 2013-116","DECISION_DT":"06/24/2014","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"308.00","DECISION_PENALTY_AMT":"277.00","sourceDate":"2012-09-06"},{"SOURCE_ROW_NUMBER":"26404","CITATION_NO":"8145107","CITATION_ISSUE_DT":"01/26/2012","DOCKET_NO":"WEVA 2012-1627","DECISION_DT":"03/29/2013","CFR_STANDARD_CODE":"77.1000","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"7300.00","DECISION_PENALTY_AMT":"3650.00","sourceDate":"2012-01-26"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":4,"firstDate":"2011-05-31","lastDate":"2022-11-15","metrics":{"recentRows":2,"currentOperatorTenures":2,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":17,"firstDate":"2012-01-10","lastDate":"2016-06-01","metrics":{"inspectors":39,"recentRows":0,"onSiteHours":412.75,"inspectionHours":730.75,"inspectionSamples":64},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"394147","EVENT_NO":"6312152","INSPECTION_BEGIN_DT":"06/01/2016","INSPECTION_END_DT":"06/01/2016","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2016-06-01"},{"SOURCE_ROW_NUMBER":"60765","EVENT_NO":"6303243","INSPECTION_BEGIN_DT":"12/16/2015","INSPECTION_END_DT":"12/16/2015","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2015-12-16"},{"SOURCE_ROW_NUMBER":"714742","EVENT_NO":"6309207","INSPECTION_BEGIN_DT":"09/22/2015","INSPECTION_END_DT":"09/22/2015","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2015-09-22"},{"SOURCE_ROW_NUMBER":"1143928","EVENT_NO":"6303226","INSPECTION_BEGIN_DT":"03/27/2015","INSPECTION_END_DT":"03/27/2015","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2015-03-27"},{"SOURCE_ROW_NUMBER":"748827","EVENT_NO":"6295448","INSPECTION_BEGIN_DT":"09/04/2014","INSPECTION_END_DT":"09/04/2014","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"7.75","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2014-09-04"},{"SOURCE_ROW_NUMBER":"318626","EVENT_NO":"6299081","INSPECTION_BEGIN_DT":"03/26/2014","INSPECTION_END_DT":"03/26/2014","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2014-03-26"},{"SOURCE_ROW_NUMBER":"242749","EVENT_NO":"6299065","INSPECTION_BEGIN_DT":"04/03/2013","INSPECTION_END_DT":"04/03/2013","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2013-04-03"},{"SOURCE_ROW_NUMBER":"1012100","EVENT_NO":"6295431","INSPECTION_BEGIN_DT":"03/18/2013","INSPECTION_END_DT":"03/18/2013","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.25","SUM_TOTAL_ON_SITE_HOURS":"3.75","sourceDate":"2013-03-18"},{"SOURCE_ROW_NUMBER":"1090302","EVENT_NO":"6295519","INSPECTION_BEGIN_DT":"10/09/2012","INSPECTION_END_DT":"12/20/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"88","SUM_TOTAL_ON_SITE_HOURS":"45.5","sourceDate":"2012-10-09"},{"SOURCE_ROW_NUMBER":"294551","EVENT_NO":"6295422","INSPECTION_BEGIN_DT":"07/27/2012","INSPECTION_END_DT":"09/27/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"7","SUM_TOTAL_INSP_HOURS":"176.5","SUM_TOTAL_ON_SITE_HOURS":"106.25","sourceDate":"2012-07-27"},{"SOURCE_ROW_NUMBER":"11940","EVENT_NO":"6295418","INSPECTION_BEGIN_DT":"04/27/2012","INSPECTION_END_DT":"06/28/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"198.75","SUM_TOTAL_ON_SITE_HOURS":"128.25","sourceDate":"2012-04-27"},{"SOURCE_ROW_NUMBER":"802678","EVENT_NO":"6288797","INSPECTION_BEGIN_DT":"04/26/2012","INSPECTION_END_DT":"04/26/2012","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2012-04-26"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":68,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2016-Q1":{"hours":0,"employees":0,"production":0},"2015-Q4":{"hours":0,"employees":0,"production":0},"2015-Q3":{"hours":0,"employees":0,"production":0},"2015-Q2":{"hours":0,"employees":0,"production":0},"2015-Q1":{"hours":0,"employees":0,"production":0},"2014-Q4":{"hours":0,"employees":0,"production":0},"2014-Q3":{"hours":0,"employees":0,"production":0},"2014-Q2":{"hours":0,"employees":0,"production":0},"2014-Q1":{"hours":0,"employees":0,"production":0},"2013-Q4":{"hours":0,"employees":0,"production":0},"2013-Q3":{"hours":10,"employees":1,"production":0},"2013-Q2":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":2,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2012":{"hours":82228,"employees":35,"production":227485},"2013":{"hours":2104,"employees":3,"production":4358}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":13,"firstDate":"2012-06-22","lastDate":"2012-09-26","metrics":{"recentRows":0,"doseOver100":2,"actDoseTotal":816,"pelDoseTotal":569},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"267100","EVENT_NO":"6295422","SURVEY_DATE":"09/26/2012","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"21","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2012-09-26"},{"SOURCE_ROW_NUMBER":"267099","EVENT_NO":"6295422","SURVEY_DATE":"09/26/2012","OCCUPATION_CD_DESC":"DISPATCHER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"46","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2012-09-26"},{"SOURCE_ROW_NUMBER":"267101","EVENT_NO":"6295422","SURVEY_DATE":"09/17/2012","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"69","PEL_DOSE_90":"52","SURVEY_TYPE":"I","sourceDate":"2012-09-17"},{"SOURCE_ROW_NUMBER":"267098","EVENT_NO":"6295418","SURVEY_DATE":"06/22/2012","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"41","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2012-06-22"},{"SOURCE_ROW_NUMBER":"267097","EVENT_NO":"6295418","SURVEY_DATE":"06/22/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"108","PEL_DOSE_90":"86","SURVEY_TYPE":"I","sourceDate":"2012-06-22"},{"SOURCE_ROW_NUMBER":"267096","EVENT_NO":"6295418","SURVEY_DATE":"06/22/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"86","PEL_DOSE_90":"69","SURVEY_TYPE":"I","sourceDate":"2012-06-22"},{"SOURCE_ROW_NUMBER":"267095","EVENT_NO":"6295418","SURVEY_DATE":"06/22/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"91","PEL_DOSE_90":"71","SURVEY_TYPE":"I","sourceDate":"2012-06-22"},{"SOURCE_ROW_NUMBER":"267094","EVENT_NO":"6295418","SURVEY_DATE":"06/22/2012","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"107","PEL_DOSE_90":"86","SURVEY_TYPE":"I","sourceDate":"2012-06-22"},{"SOURCE_ROW_NUMBER":"267093","EVENT_NO":"6295418","SURVEY_DATE":"06/22/2012","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"31","PEL_DOSE_90":"20","SURVEY_TYPE":"I","sourceDate":"2012-06-22"},{"SOURCE_ROW_NUMBER":"267092","EVENT_NO":"6295418","SURVEY_DATE":"06/22/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"55","PEL_DOSE_90":"26","SURVEY_TYPE":"I","sourceDate":"2012-06-22"},{"SOURCE_ROW_NUMBER":"267091","EVENT_NO":"6295418","SURVEY_DATE":"06/22/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"47","PEL_DOSE_90":"26","SURVEY_TYPE":"I","sourceDate":"2012-06-22"},{"SOURCE_ROW_NUMBER":"267090","EVENT_NO":"6295418","SURVEY_DATE":"06/22/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"47","PEL_DOSE_90":"27","SURVEY_TYPE":"I","sourceDate":"2012-06-22"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":37,"firstDate":"2012-01-26","lastDate":"2012-09-26","metrics":{"ss":9,"amountDue":9604,"contested":0,"amountPaid":9604,"recentRows":0,"section104d":1,"unterminated":0,"proposedPenalty":13285},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2963209","VIOLATION_NO":"7224724","VIOLATION_ISSUE_DT":"09/26/2012","SIG_SUB":"N","PART_SECTION":"75.1714-4(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/26/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-09-26"},{"SOURCE_ROW_NUMBER":"2963215","VIOLATION_NO":"8154213","VIOLATION_ISSUE_DT":"09/06/2012","SIG_SUB":"N","PART_SECTION":"77.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/06/2012","PROPOSED_PENALTY":"150","AMOUNT_DUE":"150","AMOUNT_PAID":"150","CONTESTED_IND":"N","sourceDate":"2012-09-06"},{"SOURCE_ROW_NUMBER":"2963214","VIOLATION_NO":"8154212","VIOLATION_ISSUE_DT":"09/06/2012","SIG_SUB":"N","PART_SECTION":"75.1100-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/06/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-09-06"},{"SOURCE_ROW_NUMBER":"2963212","VIOLATION_NO":"8151564","VIOLATION_ISSUE_DT":"09/06/2012","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/06/2012","PROPOSED_PENALTY":"308","AMOUNT_DUE":"277","AMOUNT_PAID":"277","CONTESTED_IND":"N","sourceDate":"2012-09-06"},{"SOURCE_ROW_NUMBER":"2963211","VIOLATION_NO":"8151563","VIOLATION_ISSUE_DT":"09/06/2012","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/06/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-09-06"},{"SOURCE_ROW_NUMBER":"2963210","VIOLATION_NO":"8151562","VIOLATION_ISSUE_DT":"09/06/2012","SIG_SUB":"N","PART_SECTION":"75.1107-4(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/11/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-09-06"},{"SOURCE_ROW_NUMBER":"2963213","VIOLATION_NO":"8154211","VIOLATION_ISSUE_DT":"09/05/2012","SIG_SUB":"N","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/05/2012","PROPOSED_PENALTY":"138","AMOUNT_DUE":"138","AMOUNT_PAID":"138","CONTESTED_IND":"N","sourceDate":"2012-09-05"},{"SOURCE_ROW_NUMBER":"2963208","VIOLATION_NO":"7178846","VIOLATION_ISSUE_DT":"08/09/2012","SIG_SUB":"Y","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/09/2012","PROPOSED_PENALTY":"285","AMOUNT_DUE":"285","AMOUNT_PAID":"285","CONTESTED_IND":"N","sourceDate":"2012-08-09"},{"SOURCE_ROW_NUMBER":"2963203","VIOLATION_NO":"8126675","VIOLATION_ISSUE_DT":"06/18/2012","SIG_SUB":"N","PART_SECTION":"75.320(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"12","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/18/2012","PROPOSED_PENALTY":"162","AMOUNT_DUE":"162","AMOUNT_PAID":"162","CONTESTED_IND":"N","sourceDate":"2012-06-18"},{"SOURCE_ROW_NUMBER":"2963202","VIOLATION_NO":"8126674","VIOLATION_ISSUE_DT":"06/18/2012","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/18/2012","PROPOSED_PENALTY":"138","AMOUNT_DUE":"138","AMOUNT_PAID":"138","CONTESTED_IND":"N","sourceDate":"2012-06-18"},{"SOURCE_ROW_NUMBER":"2963201","VIOLATION_NO":"8126673","VIOLATION_ISSUE_DT":"06/18/2012","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/18/2012","PROPOSED_PENALTY":"138","AMOUNT_DUE":"138","AMOUNT_PAID":"138","CONTESTED_IND":"N","sourceDate":"2012-06-18"},{"SOURCE_ROW_NUMBER":"2963207","VIOLATION_NO":"8139305","VIOLATION_ISSUE_DT":"06/14/2012","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/14/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-06-14"}]}],"safety":{"href":"/api/v1/mines/4609420/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609420/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1714-4","heading":"Additional self-contained self-rescuers (SCSRs).","id":"75.1714-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Additional SCSRs in work places. In addition to the requirements in §§ 75.1714, 75.1714-1, 75.1714-2, and 75.1714-3 of this part, the mine operator shall provide the following:\n\n(1) At least one additional SCSR, which provides protection for a period of one hour or longer, for each person at a fixed underground work location.\n\n(2) Additional SCSRs along the normal travel routes for pumpers, examiners, and other persons who do not have a fixed work location to be stored at a distance an average miner could walk in 30 minutes. The SCSR storage locations shall be determined by using one of the methods found under paragraph (c)(2) of this section.\n\n(b) Additional SCSRs on mantrips. If a mantrip or mobile equipment is used to enter or exit the mine, at least one additional SCSR, which provides protection for a period of one hour or longer, shall be available for each person who uses such transportation from portal to portal.\n\n(c) Additional SCSRs in escapeways. When each person underground cannot safely evacuate the mine within 30 minutes, the mine operator shall provide additional SCSRs stored in each required escapeway.\n\n(1) Each storage location shall contain at least one SCSR, which provides protection for a period of one hour or longer, for every person who will be inby that location.\n\n(2) Storage locations shall be spaced along each escapeway at 30-minute travel distances no greater than the distances determined by—\n\n(i) Calculating the distance an average miner walks in 30 minutes by using the time necessary for each miner in a sample of typical miners to walk a typical length of each escapeway; or\n\n(ii) Using the SCSR storage location spacing specified in the following table, except for escapeways with grades over 5 percent.\n\nAverage entry height Maximum distancebetween SCSR storage locations (in ft.) <40 in. (Crawl) 2,200 >40-<50 in. (Duck Walk) 3,300 >50-<65 in. (Walk Head Bent) 4,400 >65 in. (Walk Erect) 5,700\n\n(d) Additional SCSRs in hardened rooms. As an alternative to providing SCSR storage locations in each escapeway, the mine operator may store SCSRs in a hardened room located between adjacent escapeways.\n\n(1) The hardened room shall be designed and constructed to the same explosion force criteria as seals.\n\n(2) The hardened room shall include a means to provide independent, positive pressure ventilation from the surface during an emergency.\n\n(3) The District Manager shall approve the design and construction of hardened rooms in the ventilation plan.\n\n(4) These SCSR storage locations shall be spaced in accordance with paragraph (c) of this section.\n\n(e) Storage location accessibility. All SCSRs required under this section shall be stored according to the manufacturers' instructions, in conspicuous locations readily accessible by each person in the mine.\n\n(f) Storage location signs. A sign made of reflective material with the words “SCSRs” or “SELF-RESCUERS” shall be conspicuously posted at each storage location. Direction signs made of a reflective material shall be posted leading to each storage location.\n\n[71 FR 71454, Dec. 8, 2006]","occurrenceCount":1},{"chapter":"I","heading":"Electric conductors; capacity and insulation.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.503","part":"77","subchapter":"O","subpart":"F","id":"77.503","citation":"30 CFR 77.503","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-3","heading":"Condition and examination of firefighting equipment.","id":"75.1100-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"All firefighting equipment shall be maintained in a usable and operative condition. Chemical extinguishers shall be examined every 6 months and the date of the examination shall be written on a permanent tag attached to the extinguisher.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-4","heading":"Automatic fire sensors and manual actuators; installation; minimum requirements.","id":"75.1107-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a)(1) Where fire suppression devices are installed on unattended underground equipment, one or more point-type sensors or equivalent shall be installed for each 50 square feet of top surface area, or fraction thereof, of such equipment, and each sensor shall be designed to activate the first suppression system and disconnect the electrical power source to the equipment protected, and, except where sprinklers are used, there shall be in addition, a manual actuator installed to operate the system. Where sprinklers are used, provision shall be made for manual application of water to the protected equipment in lieu of a manual actuator.\n\n(2) Two or more manual actuators, where practicable, shall be installed, as provided in paragraphs (a)(2) (i) and (ii) of this section, to activate fire suppression devices on attended equipment purchased on or after the effective date of this § 75.1107-4. At least one manual actuator shall be used on equipment purchased prior to the effective date of this § 75.1107-4.\n\n(i) Manual actuators installed on attended equipment regularly operated by a miner, as provided in § 75.1107-1(c)(1) shall be located at different locations on the equipment, and at least one manual actuator shall be located within easy reach of the operator's normal operating position.\n\n(ii) Manual actuators to activate fire suppression devices on attended equipment not regularly operated by a miner, as provided in § 75.1107-1(c)(2), shall be installed at different location, and at least one manual actuator shall be installed so as to be easily reached by the miner at the jobsite or by persons approaching the equipment.\n\n(b) Sensors shall, where practicable, be installed in accordance with the recommendations set forth in National Fire Code No. 72A “Local Protective Signaling Systems” (NFPA No. 72A-1967).\n\n(c) On unattended equipment the fire suppression device shall operate independently of the power to the main motor (or equivalent) so it will remain operative if the circuit breakers (or other protective device) actuates. On attended equipment powered through a trailing cable the fire suppression device shall operate independently of the electrical power provided by the cable.\n\n(d) Point-type sensors (such as thermocouple, bimetallic strip, or rate of temperature rise) located in ventilated passageways shall be installed downwind from the equipment to be protected.\n\n(e) Sensor systems shall include a device or method for determining their operative condition.\n\n[37 FR 15301, July 29, 1972]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","heading":"Air quality detectors and measurement devices.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.320","part":"75","subchapter":"O","subpart":"D","id":"75.320","citation":"30 CFR 75.320","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609420","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}