{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4609383","name":"Mine No 1","status":"Temporarily Idled","status_date":"2017-01-25","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Logan","nearest_town":"West Logan","operator_id":"0155874","operator_name":"SNR Logan LLC","controller_id":"0136321","controller_name":"David J Stone","district":"C04","office":"Logan WV Field Office","employees":0,"latitude":37.914722,"longitude":-82.001944},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":1065},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609383","name":"Mine No 1"},"operator":{"type":"operator","id":"0155874","name":"SNR Logan LLC"},"controller":{"type":"controller","id":"0136321","name":"David J Stone"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"0113505","name":"DB Coal Mining, LLC"},"object":{"type":"mine","id":"4609383","name":"Mine No 1"},"validFrom":"2010-09-01","validTo":"2013-12-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609383|0113505|2010-09-01|2013-12-30"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0096133","name":"RDB Energy LLC et al"},"object":{"type":"mine","id":"4609383","name":"Mine No 1"},"validFrom":"2010-09-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609383|0096133|2010-09-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0096133","name":"RDB Energy LLC et al"},"object":{"type":"operator","id":"0113505","name":"DB Coal Mining, LLC"},"validFrom":"2010-09-01","validTo":"2013-12-30","current":false,"derived":true,"evidenceMineId":"4609383","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609383|0113505|2010-09-01|0096133|2010-09-01|15817"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0096133","name":"Kansas Coal LLC et al"},"object":{"type":"operator","id":"0113505","name":"DB Coal Mining, LLC"},"validFrom":"2010-09-01","validTo":"2013-12-30","current":false,"derived":true,"evidenceMineId":"4609383","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609383|0113505|2010-09-01|0096133|2010-09-01|15818"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0096133","name":"Douglas  Livingston et al"},"object":{"type":"operator","id":"0113505","name":"DB Coal Mining, LLC"},"validFrom":"2010-09-01","validTo":"2013-12-30","current":false,"derived":true,"evidenceMineId":"4609383","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609383|0113505|2010-09-01|0096133|2010-09-01|15819"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0107601","name":"Dennis  Johnson"},"object":{"type":"mine","id":"4609383","name":"Mine No 1"},"validFrom":"2013-01-29","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609383|0107601|2013-01-29|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0131473","name":"Cline Coal Company, Inc."},"object":{"type":"mine","id":"4609383","name":"Mine No 1"},"validFrom":"2013-12-31","validTo":"2014-05-26","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609383|0131473|2013-12-31|2014-05-26"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0111841","name":"Phillip M Cline"},"object":{"type":"mine","id":"4609383","name":"Mine No 1"},"validFrom":"2013-12-31","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609383|0111841|2013-12-31|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0111841","name":"Phillip M Cline"},"object":{"type":"operator","id":"0131473","name":"Cline Coal Company, Inc."},"validFrom":"2013-12-31","validTo":"2014-05-26","current":false,"derived":true,"evidenceMineId":"4609383","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609383|0131473|2013-12-31|0111841|2013-12-31|20676"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0126473","name":"Appalachian Mining and Reclamation, LLC"},"object":{"type":"mine","id":"4609383","name":"Mine No 1"},"validFrom":"2014-05-27","validTo":"2017-08-17","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609383|0126473|2014-05-27|2017-08-17"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0107601","name":"Dennis  Johnson"},"object":{"type":"operator","id":"0126473","name":"Appalachian Mining and Reclamation, LLC"},"validFrom":"2014-05-27","validTo":"2017-08-17","current":false,"derived":true,"evidenceMineId":"4609383","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609383|0126473|2014-05-27|0107601|2013-01-29|19272"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0155874","name":"SNR Logan LLC"},"object":{"type":"mine","id":"4609383","name":"Mine No 1"},"validFrom":"2017-08-18","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609383|0155874|2017-08-18|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0136321","name":"David J Stone"},"object":{"type":"mine","id":"4609383","name":"Mine No 1"},"validFrom":"2017-08-18","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609383|0136321|2017-08-18|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0136321","name":"David J Stone"},"object":{"type":"operator","id":"0155874","name":"SNR Logan LLC"},"validFrom":"2017-08-18","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609383","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609383|0155874|2017-08-18|0136321|2017-08-18|27478"}}],"coverage":{"historyRecords":6,"edgeCount":14,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":12,"firstDate":"2011-05-16","lastDate":"2015-10-05","metrics":{"daysLost":448,"injuries":12,"fatalities":0,"recentRows":0,"restrictedDays":7,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"72746","DOCUMENT_NO":"220152800001","ACCIDENT_DT":"10/05/2015","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Was attempting to remove a rock that was fouled in the #3 head. While using a pry bar to lift the rock, the bar slipped as I was pushing down causing my right hand to strike and get pinched by the bar on the edge of the #2 tail guard.","sourceDate":"2015-10-05"},{"SOURCE_ROW_NUMBER":"167523","DOCUMENT_NO":"220150130007","ACCIDENT_DT":"01/12/2015","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Scoop car/Scooptram operator, Load/Haul/Dump (LHD) operator, Teletram operator","NO_INJURIES":"1","DAYS_LOST":"370","NARRATIVE":"Employee was throwing rocks out of the feeder. He grabbed a hold of a big piece of sharp slate and threw it but before turning loose of it he caught his fingers between it and a solid piece of metal.","sourceDate":"2015-01-12"},{"SOURCE_ROW_NUMBER":"171796","DOCUMENT_NO":"220143100003","ACCIDENT_DT":"11/03/2014","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"EE said he was looking back to see which scoop man was coming behind him. When a rock fell out the top and hit him in the back. He rolled out of the deck and grabbed the rock through it out of the deck against the rib got back in the miner and backed it out to take it to a new place. After a few minutes went by ee than said he was hurting and wanted to leave","sourceDate":"2014-11-03"},{"SOURCE_ROW_NUMBER":"128542","DOCUMENT_NO":"220142940001","ACCIDENT_DT":"10/20/2014","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"53","NARRATIVE":"Employee was installing fly boards in the #5 entry after drilling his starter hole. He was attempting to put his stack together when a piece of draw rock came out of the top smashing his left middle finger against the top opening at his pusher resulting in a severe laceration.","sourceDate":"2014-10-20"},{"SOURCE_ROW_NUMBER":"8385","DOCUMENT_NO":"220142720001","ACCIDENT_DT":"09/24/2014","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"Had a double crack in 2 left that we were putting additional roof support up in the form of T3 straps (16 ft. long) when the boss left to go tend to the section for a moment. Employee attempted to install the T3 strap by himself, resulting in a strain of the back.","sourceDate":"2014-09-24"},{"SOURCE_ROW_NUMBER":"16918","DOCUMENT_NO":"220112940039","ACCIDENT_DT":"10/17/2011","DEGREE_INJURY":"ALL OTHER CASES (INCL 1ST AID)","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Cutting end off of belt cut finger.","sourceDate":"2011-10-17"},{"SOURCE_ROW_NUMBER":"232041","DOCUMENT_NO":"220112620059","ACCIDENT_DT":"09/09/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"Victim was riding on man trip with his foot vertical up and down. A low roof bolt was hanging from roof and caught his foot and rolled his foot up into the top between mine roof and man trip.","sourceDate":"2011-09-09"},{"SOURCE_ROW_NUMBER":"124188","DOCUMENT_NO":"220112690065","ACCIDENT_DT":"09/09/2011","DEGREE_INJURY":"ALL OTHER CASES (INCL 1ST AID)","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"In #6 entry the rock duster was in the scoop bucket. Employee was pushing the rock duster over in the scoop bucket when the rock duster slid over it struck him in the knee having his knee caught between the rock duster and the ram.","sourceDate":"2011-09-09"},{"SOURCE_ROW_NUMBER":"42707","DOCUMENT_NO":"220112200062","ACCIDENT_DT":"08/03/2011","DEGREE_INJURY":"ALL OTHER CASES (INCL 1ST AID)","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Absorption of radiations, caustics, toxic and noxious substances","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Got in a Yellow Jacket Nest and was bee stung.","sourceDate":"2011-08-03"},{"SOURCE_ROW_NUMBER":"77203","DOCUMENT_NO":"220112130049","ACCIDENT_DT":"07/22/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"20","NARRATIVE":"EE got finger fowled between roof bolt and roof bolt plate and cut finger.","sourceDate":"2011-07-22"},{"SOURCE_ROW_NUMBER":"197493","DOCUMENT_NO":"220111990043","ACCIDENT_DT":"07/11/2011","DEGREE_INJURY":"ALL OTHER CASES (INCL 1ST AID)","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Middle finger hit knob on steering wheel on small 4 wheeler ride (bottom end of finger had been cut off and had pins in finger years ago).","sourceDate":"2011-07-11"},{"SOURCE_ROW_NUMBER":"227761","DOCUMENT_NO":"220111510060","ACCIDENT_DT":"05/16/2011","DEGREE_INJURY":"ALL OTHER CASES (INCL 1ST AID)","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"S/C dropped in hole and bounced up causing operator to hit head against top.","sourceDate":"2011-05-16"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2017-01-25","lastDate":"2017-01-25","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":253,"firstDate":"2011-02-22","lastDate":"2015-12-07","metrics":{"ss":96,"delinquent":208,"recentRows":0,"paidPenalty":35980.44,"proposedPenalty":144853,"currentAssessment":140204},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1852774","VIOLATION_NO":"9063380","ISSUE_DT":"12/07/2015","CFR_STANDARD_CD":"49.12","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"112.00","CURRENT_ASSESSMENT_AMT":"112.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2015-12-07"},{"SOURCE_ROW_NUMBER":"1852773","VIOLATION_NO":"9063372","ISSUE_DT":"10/06/2015","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"190.00","CURRENT_ASSESSMENT_AMT":"190.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2015-10-06"},{"SOURCE_ROW_NUMBER":"1852772","VIOLATION_NO":"9063371","ISSUE_DT":"10/05/2015","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2015-10-05"},{"SOURCE_ROW_NUMBER":"1852771","VIOLATION_NO":"9063370","ISSUE_DT":"10/05/2015","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"946.00","CURRENT_ASSESSMENT_AMT":"946.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2015-10-05"},{"SOURCE_ROW_NUMBER":"1876116","VIOLATION_NO":"9065332","ISSUE_DT":"08/03/2015","CFR_STANDARD_CD":"75.364(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2015-08-03"},{"SOURCE_ROW_NUMBER":"1876115","VIOLATION_NO":"9065331","ISSUE_DT":"07/29/2015","CFR_STANDARD_CD":"75.516","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2015-07-29"},{"SOURCE_ROW_NUMBER":"1876114","VIOLATION_NO":"9065330","ISSUE_DT":"07/29/2015","CFR_STANDARD_CD":"75.508","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2015-07-29"},{"SOURCE_ROW_NUMBER":"1876113","VIOLATION_NO":"9065329","ISSUE_DT":"07/23/2015","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2015-07-23"},{"SOURCE_ROW_NUMBER":"1876112","VIOLATION_NO":"9065328","ISSUE_DT":"07/22/2015","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2015-07-22"},{"SOURCE_ROW_NUMBER":"1876111","VIOLATION_NO":"9065327","ISSUE_DT":"07/21/2015","CFR_STANDARD_CD":"75.1103-5(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2015-07-21"},{"SOURCE_ROW_NUMBER":"1876110","VIOLATION_NO":"9065326","ISSUE_DT":"07/21/2015","CFR_STANDARD_CD":"77.809","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"946.00","CURRENT_ASSESSMENT_AMT":"946.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2015-07-21"},{"SOURCE_ROW_NUMBER":"1876109","VIOLATION_NO":"9065325","ISSUE_DT":"07/20/2015","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2015-07-20"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":5,"firstDate":"2013-07-18","lastDate":"2013-10-23","metrics":{"appeals":0,"decisions":5,"recentRows":0,"decisionPenalty":9987,"originalPenalty":14636},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"316395","VIOLATION_NO":"8132947","DOCKET_NO":"WEVA 2012-542","DECISION_DT":"10/23/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3143.00","DECISION_PENALTY_AMT":"2325.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2013-10-23"},{"SOURCE_ROW_NUMBER":"81685","VIOLATION_NO":"8132949","DOCKET_NO":"WEVA 2012-542","DECISION_DT":"10/23/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3493.00","DECISION_PENALTY_AMT":"2325.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2013-10-23"},{"SOURCE_ROW_NUMBER":"340738","VIOLATION_NO":"8141752","DOCKET_NO":"WEVA 2013-656","DECISION_DT":"09/18/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4000.00","DECISION_PENALTY_AMT":"2000.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2013-09-18"},{"SOURCE_ROW_NUMBER":"318341","VIOLATION_NO":"8140211","DOCKET_NO":"WEVA 2012-685","DECISION_DT":"07/18/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2000.00","DECISION_PENALTY_AMT":"2000.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2013-07-18"},{"SOURCE_ROW_NUMBER":"82832","VIOLATION_NO":"8140209","DOCKET_NO":"WEVA 2012-685","DECISION_DT":"07/18/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2000.00","DECISION_PENALTY_AMT":"1337.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2013-07-18"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":179,"firstDate":"2011-05-12","lastDate":"2015-08-31","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":40,"validSamples":139,"maxConcentration":6.812,"concentrationTotal":77.863},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1013686","CASS_NUM":"51420745","SMP_TAKEN_DT":"8/31/2015","CONC":".165","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"DISCARDED SAMPLE (TOO OLD)","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-08-31"},{"SOURCE_ROW_NUMBER":"1104368","CASS_NUM":"51420785","SMP_TAKEN_DT":"8/29/2015","CONC":".135","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"CONTROL FILTER INVALID","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-08-29"},{"SOURCE_ROW_NUMBER":"561611","CASS_NUM":"51382922","SMP_TAKEN_DT":"8/28/2015","CONC":".087","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-08-28"},{"SOURCE_ROW_NUMBER":"659494","CASS_NUM":"51382929","SMP_TAKEN_DT":"8/27/2015","CONC":".401","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-08-27"},{"SOURCE_ROW_NUMBER":"1122276","CASS_NUM":"51382921","SMP_TAKEN_DT":"8/26/2015","CONC":".365","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-08-26"},{"SOURCE_ROW_NUMBER":"1433405","CASS_NUM":"58182447","SMP_TAKEN_DT":"7/27/2015","CONC":".535","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ELECTRICIAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-07-27"},{"SOURCE_ROW_NUMBER":"1415269","CASS_NUM":"58182358","SMP_TAKEN_DT":"7/27/2015","CONC":".05","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-07-27"},{"SOURCE_ROW_NUMBER":"866035","CASS_NUM":"58182442","SMP_TAKEN_DT":"7/27/2015","CONC":".09","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-07-27"},{"SOURCE_ROW_NUMBER":"583136","CASS_NUM":"58182446","SMP_TAKEN_DT":"7/27/2015","CONC":".146","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-07-27"},{"SOURCE_ROW_NUMBER":"501257","CASS_NUM":"58182411","SMP_TAKEN_DT":"7/27/2015","CONC":".308","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-07-27"},{"SOURCE_ROW_NUMBER":"27583","CASS_NUM":"58182422","SMP_TAKEN_DT":"7/27/2015","CONC":".432","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-07-27"},{"SOURCE_ROW_NUMBER":"935796","CASS_NUM":"51382913","SMP_TAKEN_DT":"6/25/2015","CONC":".03","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"UNREPRESENTATIVE SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-06-25"}]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":5,"firstDate":"2011-05-26","lastDate":"2011-10-04","metrics":{"decisions":5,"ssChanged":0,"recentRows":0,"decisionPenalty":9987,"proposedPenalty":14636},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"192776","CITATION_NO":"8141752","CITATION_ISSUE_DT":"10/04/2011","DOCKET_NO":"WEVA 2013-656","DECISION_DT":"09/18/2013","CFR_STANDARD_CODE":"75.507-1(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"4000.00","DECISION_PENALTY_AMT":"2000.00","sourceDate":"2011-10-04"},{"SOURCE_ROW_NUMBER":"365236","CITATION_NO":"8140211","CITATION_ISSUE_DT":"09/30/2011","DOCKET_NO":"WEVA 2012-685","DECISION_DT":"07/18/2013","CFR_STANDARD_CODE":"75.523-3(b)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2000.00","DECISION_PENALTY_AMT":"2000.00","sourceDate":"2011-09-30"},{"SOURCE_ROW_NUMBER":"27740","CITATION_NO":"8140209","CITATION_ISSUE_DT":"09/30/2011","DOCKET_NO":"WEVA 2012-685","DECISION_DT":"07/18/2013","CFR_STANDARD_CODE":"75.523-2(c)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2000.00","DECISION_PENALTY_AMT":"1337.00","sourceDate":"2011-09-30"},{"SOURCE_ROW_NUMBER":"363603","CITATION_NO":"8132947","CITATION_ISSUE_DT":"05/26/2011","DOCKET_NO":"WEVA 2012-542","DECISION_DT":"10/23/2013","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3143.00","DECISION_PENALTY_AMT":"2325.00","sourceDate":"2011-05-26"},{"SOURCE_ROW_NUMBER":"137130","CITATION_NO":"8132949","CITATION_ISSUE_DT":"05/26/2011","DOCKET_NO":"WEVA 2012-542","DECISION_DT":"10/23/2013","CFR_STANDARD_CODE":"75.362(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3493.00","DECISION_PENALTY_AMT":"2325.00","sourceDate":"2011-05-26"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":141,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":31,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":6,"firstDate":"2010-09-01","lastDate":"2017-08-18","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":5},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":51,"firstDate":"2011-01-19","lastDate":"2026-06-30","metrics":{"inspectors":73,"recentRows":2,"onSiteHours":1513.25,"inspectionHours":2450.25,"inspectionSamples":321},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"342439","EVENT_NO":"F03DF73","INSPECTION_BEGIN_DT":"06/30/2026","INSPECTION_END_DT":"06/30/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.25","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2026-06-30"},{"SOURCE_ROW_NUMBER":"494640","EVENT_NO":"7017333","INSPECTION_BEGIN_DT":"10/04/2021","INSPECTION_END_DT":"10/04/2021","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2021-10-04"},{"SOURCE_ROW_NUMBER":"442233","EVENT_NO":"6308498","INSPECTION_BEGIN_DT":"10/13/2020","INSPECTION_END_DT":"10/13/2020","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2020-10-13"},{"SOURCE_ROW_NUMBER":"437692","EVENT_NO":"7016194","INSPECTION_BEGIN_DT":"08/05/2020","INSPECTION_END_DT":"08/05/2020","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.25","SUM_TOTAL_ON_SITE_HOURS":"3.25","sourceDate":"2020-08-05"},{"SOURCE_ROW_NUMBER":"1062446","EVENT_NO":"6307099","INSPECTION_BEGIN_DT":"01/10/2017","INSPECTION_END_DT":"01/10/2017","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.25","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2017-01-10"},{"SOURCE_ROW_NUMBER":"391485","EVENT_NO":"6308389","INSPECTION_BEGIN_DT":"11/14/2016","INSPECTION_END_DT":"11/14/2016","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2016-11-14"},{"SOURCE_ROW_NUMBER":"269250","EVENT_NO":"6307074","INSPECTION_BEGIN_DT":"10/04/2016","INSPECTION_END_DT":"10/05/2016","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2016-10-04"},{"SOURCE_ROW_NUMBER":"389824","EVENT_NO":"6307613","INSPECTION_BEGIN_DT":"07/21/2016","INSPECTION_END_DT":"07/21/2016","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2016-07-21"},{"SOURCE_ROW_NUMBER":"920763","EVENT_NO":"6308260","INSPECTION_BEGIN_DT":"06/13/2016","INSPECTION_END_DT":"06/13/2016","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2016-06-13"},{"SOURCE_ROW_NUMBER":"868626","EVENT_NO":"6307607","INSPECTION_BEGIN_DT":"06/08/2016","INSPECTION_END_DT":"06/21/2016","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11.75","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2016-06-08"},{"SOURCE_ROW_NUMBER":"1053523","EVENT_NO":"6300887","INSPECTION_BEGIN_DT":"01/12/2016","INSPECTION_END_DT":"03/31/2016","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"39.5","SUM_TOTAL_ON_SITE_HOURS":"16.5","sourceDate":"2016-01-12"},{"SOURCE_ROW_NUMBER":"500458","EVENT_NO":"6306643","INSPECTION_BEGIN_DT":"01/07/2016","INSPECTION_END_DT":"01/07/2016","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2016-01-07"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":48,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2015-Q4":{"hours":8028,"employees":31,"production":3042},"2015-Q2":{"hours":13519,"employees":23,"production":14434},"2015-Q1":{"hours":8332,"employees":16,"production":9593},"2014-Q4":{"hours":8712,"employees":14,"production":8902},"2014-Q3":{"hours":6947,"employees":21,"production":3167},"2014-Q2":{"hours":604,"employees":6,"production":0},"2013-Q4":{"hours":1114,"employees":7,"production":674},"2013-Q3":{"hours":11072,"employees":23,"production":9051},"2013-Q2":{"hours":2692,"employees":8,"production":0},"2013-Q1":{"hours":1320,"employees":3,"production":0},"2012-Q4":{"hours":1320,"employees":3,"production":0},"2012-Q3":{"hours":480,"employees":1,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":12,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2011":{"hours":31228,"employees":19,"production":26976},"2012":{"hours":4220,"employees":4,"production":0},"2013":{"hours":16198,"employees":21,"production":9725},"2014":{"hours":16263,"employees":13,"production":12069},"2015":{"hours":29879,"employees":23,"production":27069}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":50,"firstDate":"2011-06-23","lastDate":"2015-08-25","metrics":{"recentRows":0,"doseOver100":2,"actDoseTotal":3181,"pelDoseTotal":2678},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"266611","EVENT_NO":"6307151","SURVEY_DATE":"08/25/2015","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"65","PEL_DOSE_90":"56","SURVEY_TYPE":"I","sourceDate":"2015-08-25"},{"SOURCE_ROW_NUMBER":"266610","EVENT_NO":"6307151","SURVEY_DATE":"08/25/2015","OCCUPATION_CD_DESC":"BULLGANG FOREMAN/LABOR FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"62","PEL_DOSE_90":"52","SURVEY_TYPE":"I","sourceDate":"2015-08-25"},{"SOURCE_ROW_NUMBER":"266609","EVENT_NO":"6307151","SURVEY_DATE":"08/25/2015","OCCUPATION_CD_DESC":"DISPATCHER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"76","PEL_DOSE_90":"70","SURVEY_TYPE":"I","sourceDate":"2015-08-25"},{"SOURCE_ROW_NUMBER":"266608","EVENT_NO":"6307151","SURVEY_DATE":"07/23/2015","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"39","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2015-07-23"},{"SOURCE_ROW_NUMBER":"266607","EVENT_NO":"6307151","SURVEY_DATE":"07/23/2015","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"35","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2015-07-23"},{"SOURCE_ROW_NUMBER":"266606","EVENT_NO":"6307151","SURVEY_DATE":"07/23/2015","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"018","ACT_DOSE_85":"76","PEL_DOSE_90":"58","SURVEY_TYPE":"I","sourceDate":"2015-07-23"},{"SOURCE_ROW_NUMBER":"266605","EVENT_NO":"6307151","SURVEY_DATE":"07/23/2015","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"65","PEL_DOSE_90":"38","SURVEY_TYPE":"I","sourceDate":"2015-07-23"},{"SOURCE_ROW_NUMBER":"266604","EVENT_NO":"6307151","SURVEY_DATE":"07/23/2015","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"78","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2015-07-23"},{"SOURCE_ROW_NUMBER":"266603","EVENT_NO":"6307151","SURVEY_DATE":"07/23/2015","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"56","PEL_DOSE_90":"37","SURVEY_TYPE":"I","sourceDate":"2015-07-23"},{"SOURCE_ROW_NUMBER":"266602","EVENT_NO":"6307151","SURVEY_DATE":"07/23/2015","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"20","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2015-07-23"},{"SOURCE_ROW_NUMBER":"266601","EVENT_NO":"6301867","SURVEY_DATE":"08/07/2014","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"82","PEL_DOSE_90":"81","SURVEY_TYPE":"I","sourceDate":"2014-08-07"},{"SOURCE_ROW_NUMBER":"266600","EVENT_NO":"6301867","SURVEY_DATE":"08/07/2014","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"70","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2014-08-07"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":14,"firstDate":"2011-06-13","lastDate":"2015-07-27","metrics":{"recentRows":0,"voidSamples":1,"maxQuartzPct":19.5,"validSamples":13,"quartzPctTotal":110.6},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"70274","CASSETTE_NO":"58182411","SAMPLE_DT":"07/27/2015","QUARTZ_PCT":"08.8","QUARTZ_MICROGRAMS":"27","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-07-27"},{"SOURCE_ROW_NUMBER":"162770","CASSETTE_NO":"58181432","SAMPLE_DT":"05/28/2015","QUARTZ_PCT":"05.3","QUARTZ_MICROGRAMS":"31","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-05-28"},{"SOURCE_ROW_NUMBER":"17161","CASSETTE_NO":"58181448","SAMPLE_DT":"05/28/2015","QUARTZ_PCT":"05.6","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-05-28"},{"SOURCE_ROW_NUMBER":"33029","CASSETTE_NO":"58171742","SAMPLE_DT":"03/12/2015","QUARTZ_PCT":"06.4","QUARTZ_MICROGRAMS":"76","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-03-12"},{"SOURCE_ROW_NUMBER":"37549","CASSETTE_NO":"58172402","SAMPLE_DT":"12/16/2014","QUARTZ_PCT":"05.5","QUARTZ_MICROGRAMS":"25","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-12-16"},{"SOURCE_ROW_NUMBER":"139060","CASSETTE_NO":"58152854","SAMPLE_DT":"05/07/2014","QUARTZ_PCT":"09.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-05-07"},{"SOURCE_ROW_NUMBER":"151491","CASSETTE_NO":"58013325","SAMPLE_DT":"09/05/2013","QUARTZ_PCT":"02.1","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-09-05"},{"SOURCE_ROW_NUMBER":"162626","CASSETTE_NO":"58002327","SAMPLE_DT":"08/13/2013","QUARTZ_PCT":"04.5","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-08-13"},{"SOURCE_ROW_NUMBER":"167272","CASSETTE_NO":"57912561","SAMPLE_DT":"10/12/2011","QUARTZ_PCT":"17.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-10-12"},{"SOURCE_ROW_NUMBER":"72775","CASSETTE_NO":"57912527","SAMPLE_DT":"10/12/2011","QUARTZ_PCT":"11.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-10-12"},{"SOURCE_ROW_NUMBER":"64845","CASSETTE_NO":"57912585","SAMPLE_DT":"10/12/2011","QUARTZ_PCT":"11.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-10-12"},{"SOURCE_ROW_NUMBER":"82808","CASSETTE_NO":"51122530","SAMPLE_DT":"07/20/2011","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2011-07-20"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":256,"firstDate":"2011-02-22","lastDate":"2015-12-15","metrics":{"ss":96,"amountDue":140204,"contested":0,"amountPaid":35980.44,"recentRows":0,"section104d":10,"unterminated":3,"proposedPenalty":144853},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2962239","VIOLATION_NO":"9063383","VIOLATION_ISSUE_DT":"12/15/2015","PART_SECTION":"49.12","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"03/31/2016","CONTESTED_IND":"N","sourceDate":"2015-12-15"},{"SOURCE_ROW_NUMBER":"2962238","VIOLATION_NO":"9063380","VIOLATION_ISSUE_DT":"12/07/2015","SIG_SUB":"N","PART_SECTION":"49.12","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","PROPOSED_PENALTY":"112","AMOUNT_DUE":"112","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2015-12-07"},{"SOURCE_ROW_NUMBER":"2962237","VIOLATION_NO":"9063372","VIOLATION_ISSUE_DT":"10/06/2015","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/06/2015","PROPOSED_PENALTY":"190","AMOUNT_DUE":"190","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2015-10-06"},{"SOURCE_ROW_NUMBER":"2962236","VIOLATION_NO":"9063371","VIOLATION_ISSUE_DT":"10/05/2015","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/05/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2015-10-05"},{"SOURCE_ROW_NUMBER":"2962235","VIOLATION_NO":"9063370","VIOLATION_ISSUE_DT":"10/05/2015","SIG_SUB":"Y","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/05/2015","PROPOSED_PENALTY":"946","AMOUNT_DUE":"946","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2015-10-05"},{"SOURCE_ROW_NUMBER":"2962221","VIOLATION_NO":"9065332","VIOLATION_ISSUE_DT":"08/03/2015","SIG_SUB":"N","PART_SECTION":"75.364(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/03/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2015-08-03"},{"SOURCE_ROW_NUMBER":"2962220","VIOLATION_NO":"9065331","VIOLATION_ISSUE_DT":"07/29/2015","SIG_SUB":"N","PART_SECTION":"75.516","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/29/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2015-07-29"},{"SOURCE_ROW_NUMBER":"2962219","VIOLATION_NO":"9065330","VIOLATION_ISSUE_DT":"07/29/2015","SIG_SUB":"N","PART_SECTION":"75.508","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/29/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2015-07-29"},{"SOURCE_ROW_NUMBER":"2962218","VIOLATION_NO":"9065329","VIOLATION_ISSUE_DT":"07/23/2015","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/27/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2015-07-23"},{"SOURCE_ROW_NUMBER":"2962217","VIOLATION_NO":"9065328","VIOLATION_ISSUE_DT":"07/22/2015","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/22/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2015-07-22"},{"SOURCE_ROW_NUMBER":"2962216","VIOLATION_NO":"9065327","VIOLATION_ISSUE_DT":"07/21/2015","SIG_SUB":"N","PART_SECTION":"75.1103-5(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/21/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2015-07-21"},{"SOURCE_ROW_NUMBER":"2962215","VIOLATION_NO":"9065326","VIOLATION_ISSUE_DT":"07/21/2015","SIG_SUB":"Y","PART_SECTION":"77.809","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/21/2015","PROPOSED_PENALTY":"946","AMOUNT_DUE":"946","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2015-07-21"}]}],"safety":{"href":"/api/v1/mines/4609383/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609383/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Availability of mine rescue teams.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-49/subpart-B/section-49.12","part":"49","subchapter":"H","subpart":"B","id":"49.12","citation":"30 CFR 49.12","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","partHeading":"PART 49—MINE RESCUE TEAMS","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.364","heading":"Weekly examination.","id":"75.364","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.364","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Worked-out areas. (1) At least every 7 days, a certified person shall examine unsealed worked-out areas where no pillars have been recovered by traveling to the area of deepest penetration; measuring methane and oxygen concentrations and air quantities and making tests to determine if the air is moving in the proper direction in the area. The locations of measurement points where tests and measurements will be performed shall be included in the mine ventilation plan and shall be adequate in number and location to assure ventilation and air quality in the area. Air quantity measurements shall also be made where the air enters and leaves the worked-out area. An alternative method of evaluating the ventilation of the area may be approved in the ventilation plan.\n\n(2) At least every 7 days, a certified person shall evaluate the effectiveness of bleeder systems required by § 75.334 as follows:\n\n(i) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in its proper direction shall be made where air enters the worked-out area.\n\n(ii) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in the proper direction shall be made immediately before the air enters a return split of air.\n\n(iii) At least one entry of each set of bleeder entries used as part of a bleeder system under § 75.334 shall be traveled in its entirety. Measurements of methane and oxygen concentrations and air quantities and a test to determine if the air is moving in the proper direction shall be made at the measurement point locations specified in the mine ventilation plan to determine the effectiveness of the bleeder system.\n\n(iv) In lieu of the requirements of paragraphs (a)(2)(i) and (iii) of this section, an alternative method of evaluation may be specified in the ventilation plan provided the alternative method results in proper evaluation of the effectiveness of the bleeder system.\n\n(b) Hazardous conditions and violations of mandatory health or safety standards. At least every 7 days, an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(8) of this section shall be made by a certified person designated by the operator at the following locations:\n\n(1) In at least one entry of each intake air course, in its entirety, so that the entire air course is traveled.\n\n(2) In at least one entry of each return air course, in its entirety, so that the entire air course is traveled.\n\n(3) In each longwall or shortwall travelway in its entirety, so that the entire travelway is traveled.\n\n(4) At each seal along return and bleeder air courses and at each seal along intake air courses not examined under § 75.360(b)(5).\n\n(5) In each escapeway so that the entire escapeway is traveled.\n\n(6) On each working section not examined under § 75.360(b)(3) during the previous 7 days.\n\n(7) At each water pump not examined during a preshift examination conducted during the previous 7 days.\n\n(8) Weekly examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust; and\n\n(iv) § 75.1403—maintenance of off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) Measurements and tests. At least every 7 days, a certified person shall—\n\n(1) Determine the volume of air entering the main intakes and in each intake split;\n\n(2) Determine the volume of air and test for methane in the last open crosscut in any pair or set of developing entries or rooms, in the return of each split of air immediately before it enters the main returns, and where the air leaves the main returns; and\n\n(3) Test for methane in the return entry nearest each set of seals immediately after the air passes the seals.\n\n(d) Hazardous conditions shall be corrected immediately. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Any violation of the nine mandatory health or safety standards found during a weekly examination shall be corrected.\n\n(e) The weekly examination may be conducted at the same time as the preshift or on-shift examinations.\n\n(f) (1) The weekly examination is not required during any 7 day period in which no one enters any underground area of the mine.\n\n(2) Except for certified persons required to make examinations, no one shall enter any underground area of the mine if a weekly examination has not been completed within the previous 7 days.\n\n(g) Certification. The person making the weekly examinations shall certify by initials, date, and the time that the examination was made. Certifications and times shall appear at enough locations to show that the entire area has been examined.\n\n(h) Recordkeeping. At the completion of any shift during which a portion of a weekly examination is conducted, a record of the results of each weekly examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards found during each examination and their locations, the corrective action taken, and the results and location of air and methane measurements, shall be made. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the person making the examination or a person designated by the operator. If made by a person other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(i) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 77 FR 20715, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.516","heading":"Power wires; support.","id":"75.516","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.516","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll power wires (except trailing cables on mobile equipment, specially designed cables conducting high-voltage power to underground rectifying equipment or transformers, or bare or insulated ground and return wires) shall be supported on well-insulated insulators and shall not contact combustible material, roof, or ribs.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.508","heading":"Map of electrical system.","id":"75.508","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.508","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe location and the electrical rating of all stationary electric apparatus in connection with the mine electric system, including permanent cables, switchgear, rectifying substations, transformers, permanent pumps, and trolley wires and trolley feeder wires, and settings of all direct-current circuit breakers protecting underground trolley circuits, shall be shown on a mine map. Any changes made in a location, electric rating, or setting shall be promptly shown on the map when the change is made. Such map shall be available to an authorized representative of the Secretary and to the miners in such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1103-5","heading":"Automatic fire warning devices; actions and response.","id":"75.1103-5","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103-5","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) When the carbon monoxide level reaches 10 parts per million above the established ambient level at any sensor location, automatic fire sensor and warning device systems shall provide an effective warning signal at the following locations:\n\n(1) At working sections and other work locations where miners may be endangered from a fire in the belt entry.\n\n(2) At a manned surface location where personnel have an assigned post of duty. The manned surface location must have:\n\n(i) A telephone or equivalent communication with all miners who may be endangered and\n\n(ii) A map or schematic that shows the locations of sensors, and the intended air flow direction at these locations. This map or schematic must be updated within 24 hours of any change in this information.\n\n(3) The automatic fire sensor and warning device system shall be monitored for a period of 4 hours after the belt is stopped, unless an examination for hot rollers and fire is made as prescribed in § 75.1103-4(e).\n\n(b) The fire sensor and warning device system shall include a means for rapid evaluation of electrical short and open circuits, ground faults, pneumatic leaks, or other defect detrimental to its proper operational condition.\n\n(c) Automatic fire sensor and warning devices shall include a manual reset feature.\n\n(d) When a malfunction or warning signal is received at the manned surface location, the sensors that are activated must be identified and appropriate personnel immediately notified.\n\n(e) Upon notification of a malfunction or warning signal, appropriate personnel must immediately initiate an investigation to determine the cause of the malfunction or warning signal and take the required actions set forth in paragraph (f) of this section.\n\n(f) If any sensor indicates a warning, the following actions must be taken unless the mine operator determines that the signal does not present a hazard to miners:\n\n(1) Appropriate personnel must notify miners in affected working sections, in affected areas where mechanized mining equipment is being installed or removed, and at other locations specified in the approved mine emergency evacuation and firefighting program of instruction; and\n\n(2) All miners in the affected areas, unless assigned emergency response duties, must be immediately withdrawn to a safe location identified in the mine emergency evacuation and firefighting program of instruction.\n\n(g) If the warning signal will be activated during calibration of sensors, personnel manning the surface location must be notified prior to and upon completion of calibration. Affected working sections, areas where mechanized mining equipment is being installed or removed, or other areas designated in the approved emergency evacuation and firefighting program of instruction must be notified at the beginning and completion of calibration.\n\n(h) If any fire detection component becomes inoperative, immediate action must be taken to repair the component. While repairs are being made, operation of the belt may continue if the following requirements are met:\n\n(1) If one sensor becomes inoperative, a trained person must continuously monitor for carbon monoxide at the inoperative sensor;\n\n(2) If two or more adjacent sensors become inoperative, trained persons must patrol and continuously monitor the affected areas for carbon monoxide so that they will be traveled each hour in their entirety. Alternatively, a trained person must be stationed at each inoperative sensor to monitor for carbon monoxide;\n\n(3) If the complete fire detection system becomes inoperative, trained persons must patrol and continuously monitor the affected areas for carbon monoxide so that they will be traveled each hour in their entirety;\n\n(4) Trained persons who conduct monitoring under this section must have two-way voice communication capability, at intervals not to exceed 2,000 feet, and must report carbon monoxide concentrations to the surface at intervals not to exceed one hour;\n\n(5) Trained persons who conduct monitoring under this section must immediately report to the surface any concentration of carbon monoxide that reaches 10 parts per million above the established ambient level, unless the mine operator knows that the source of the carbon monoxide does not present a hazard to miners; and\n\n(6) Handheld detectors used to monitor the belt entry under this section must have a detection level equivalent to that of the system's carbon monoxide sensors.\n\n[37 FR 16545, Aug. 16, 1972, as amended at 73 FR 80615, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.809","heading":"Identification of circuit breakers and disconnecting switches.","id":"77.809","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-I/section-77.809","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"I","subpartHeading":"Subpart I—Surface High-Voltage Distribution","text":"Circuit breakers and disconnecting switches shall be labeled to show which units they control, unless identification can be made readily by location.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609383","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}