{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4609353","name":"Jackson Bridge 1","status":"Abandoned and Sealed","status_date":"2019-10-16","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Webster","nearest_town":"Prestonia","operator_id":"0051081","operator_name":"Brooks Run Mining Company LLC","controller_id":"0137121","controller_name":"Pristine Clean Energy LLC","district":"C04","office":"Summersville WV Field Office","employees":0,"latitude":38.544722,"longitude":-80.658333},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":1156},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609353","name":"Jackson Bridge 1"},"operator":{"type":"operator","id":"0051081","name":"Brooks Run Mining Company LLC"},"controller":{"type":"controller","id":"0137121","name":"Pristine Clean Energy LLC"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"4609353","name":"Jackson Bridge 1"},"validFrom":"2003-02-01","validTo":"2016-07-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609353|0041211|2003-02-01|2016-07-25"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0051081","name":"Brooks Run Mining Company LLC"},"object":{"type":"mine","id":"4609353","name":"Jackson Bridge 1"},"validFrom":"2009-09-23","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609353|0051081|2009-09-23|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"0051081","name":"Brooks Run Mining Company LLC"},"validFrom":"2009-09-23","validTo":"2016-07-25","current":false,"derived":true,"evidenceMineId":"4609353","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609353|0051081|2009-09-23|0041211|2003-02-01|1687"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"mine","id":"4609353","name":"Jackson Bridge 1"},"validFrom":"2016-07-26","validTo":"2017-10-04","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609353|0127923|2016-07-26|2017-10-04"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"operator","id":"0051081","name":"Brooks Run Mining Company LLC"},"validFrom":"2016-07-26","validTo":"2017-10-04","current":false,"derived":true,"evidenceMineId":"4609353","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609353|0051081|2009-09-23|0127923|2016-07-26|25103"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0137121","name":"Pristine Clean Energy LLC"},"object":{"type":"mine","id":"4609353","name":"Jackson Bridge 1"},"validFrom":"2017-10-05","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609353|0137121|2017-10-05|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0137121","name":"Pristine Clean Energy LLC"},"object":{"type":"operator","id":"0051081","name":"Brooks Run Mining Company LLC"},"validFrom":"2017-10-05","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609353","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609353|0051081|2009-09-23|0137121|2017-10-05|27652"}}],"coverage":{"historyRecords":3,"edgeCount":7,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":19,"firstDate":"2012-12-13","lastDate":"2016-06-10","metrics":{"daysLost":814,"injuries":19,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"193235","DOCUMENT_NO":"220161820001","ACCIDENT_DT":"06/10/2016","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Safety director","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The operator was notified of a claim for Occupational Pneumoconiosis after mining has ceased and the affected employee was laid off. The operator wishes to report the Illness Claim and terminate the affected miners employment since mining equipment has been removed and mine entrances are sealed.","sourceDate":"2016-06-10"},{"SOURCE_ROW_NUMBER":"8381","DOCUMENT_NO":"220161830006","ACCIDENT_DT":"06/10/2016","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"After mining had ceased and mine entrances sealed, the operator received notice of Occupational Illness on the named EE. After reviewing part 50 reporting and present status of the sealed mine we wish to report the illness claim and terminate employment on date 6/20/16 that mine was reported abandoned to MSHA.","sourceDate":"2016-06-10"},{"SOURCE_ROW_NUMBER":"124185","DOCUMENT_NO":"220161830004","ACCIDENT_DT":"06/04/2016","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"After mining had ceased and mine entrances sealed, the operator received notice of Occupational Illness on the named EE. After reviewing part 50 reporting and present status of the sealed mine we which to report the illness claim and terminate employment on date 6/20/16 that mine was reported abandoned to MSHA.","sourceDate":"2016-06-04"},{"SOURCE_ROW_NUMBER":"55609","DOCUMENT_NO":"220160470038","ACCIDENT_DT":"02/12/2016","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"346","NARRATIVE":"Employee was walking back to the face area in the intake entry when they slipped on ice and fell. Diagnosed with fracture to the left fibula.","sourceDate":"2016-02-12"},{"SOURCE_ROW_NUMBER":"158898","DOCUMENT_NO":"220160470030","ACCIDENT_DT":"02/02/2016","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","NARRATIVE":"The operator was notified on 2/2/2016 that the employee has been diagnosed with Occupational Pneumoconiosis.","sourceDate":"2016-02-02"},{"SOURCE_ROW_NUMBER":"232035","DOCUMENT_NO":"220160280025","ACCIDENT_DT":"01/18/2016","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"Pulling miner cable slack to be hung & strained lower back.","sourceDate":"2016-01-18"},{"SOURCE_ROW_NUMBER":"59853","DOCUMENT_NO":"220153240018","ACCIDENT_DT":"11/11/2015","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The operator was notified on 11/11/2015 that the former employee (last exposure date worked 4-10-2014) has been diagnosed with Occupational Pneumoconiosis.","sourceDate":"2015-11-11"},{"SOURCE_ROW_NUMBER":"132885","DOCUMENT_NO":"220153240027","ACCIDENT_DT":"11/10/2015","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Utility man, Errand boy, Service truck operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The operator was notified on 11/10/2015 that the employee has been diagnosed with Occupational Pneumoconiosis.","sourceDate":"2015-11-10"},{"SOURCE_ROW_NUMBER":"232034","DOCUMENT_NO":"220151620004","ACCIDENT_DT":"06/05/2015","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The operator has been notified that the employee has been diagnosed with pneumoconiosis.","sourceDate":"2015-06-05"},{"SOURCE_ROW_NUMBER":"16913","DOCUMENT_NO":"220151620001","ACCIDENT_DT":"06/05/2015","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Superintendent","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The operator has been notified that the employee has been diagnosed with pneumoconiosis.","sourceDate":"2015-06-05"},{"SOURCE_ROW_NUMBER":"270696","DOCUMENT_NO":"220143380034","ACCIDENT_DT":"12/02/2014","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"Employee was walking along side the feeder in mud and a slight incline and slipped and fell resulting in a pulled calve muscle.","sourceDate":"2014-12-02"},{"SOURCE_ROW_NUMBER":"270695","DOCUMENT_NO":"220143010022","ACCIDENT_DT":"10/17/2014","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Belt foreman, Maintenance foreman, Maintenance supervisor","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Brooks Run Mining Co. was informed that retired employee has been diagnosed with Occupational Simple Pneumoconiosis on 10/1/14. He was employed by Brooks Run Mining from 4/6/98 to 7/10/14 as a Maintenance Foreman. His last day of work for Brooks Run was on 7/10/14.","sourceDate":"2014-10-17"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2019-10-16","lastDate":"2019-10-16","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":127,"firstDate":"2012-06-12","lastDate":"2016-02-23","metrics":{"ss":37,"delinquent":115,"recentRows":0,"paidPenalty":51177,"proposedPenalty":53103,"currentAssessment":51177},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1881743","VIOLATION_NO":"9060226","ISSUE_DT":"02/23/2016","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"362.00","CURRENT_ASSESSMENT_AMT":"362.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2016-02-23"},{"SOURCE_ROW_NUMBER":"1881742","VIOLATION_NO":"9060225","ISSUE_DT":"02/22/2016","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"362.00","CURRENT_ASSESSMENT_AMT":"362.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2016-02-22"},{"SOURCE_ROW_NUMBER":"1881736","VIOLATION_NO":"9055490","ISSUE_DT":"02/17/2016","CFR_STANDARD_CD":"75.518-1","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2016-02-17"},{"SOURCE_ROW_NUMBER":"1881735","VIOLATION_NO":"9055489","ISSUE_DT":"02/17/2016","CFR_STANDARD_CD":"75.900-4","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2016-02-17"},{"SOURCE_ROW_NUMBER":"1881741","VIOLATION_NO":"9060224","ISSUE_DT":"02/10/2016","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"540.00","CURRENT_ASSESSMENT_AMT":"540.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2016-02-10"},{"SOURCE_ROW_NUMBER":"1881740","VIOLATION_NO":"9060223","ISSUE_DT":"01/27/2016","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2016-01-27"},{"SOURCE_ROW_NUMBER":"1881739","VIOLATION_NO":"9060222","ISSUE_DT":"01/20/2016","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1203.00","CURRENT_ASSESSMENT_AMT":"1203.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2016-01-20"},{"SOURCE_ROW_NUMBER":"1881738","VIOLATION_NO":"9060221","ISSUE_DT":"01/19/2016","CFR_STANDARD_CD":"75.364(b)(4)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"162.00","CURRENT_ASSESSMENT_AMT":"162.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2016-01-19"},{"SOURCE_ROW_NUMBER":"1881737","VIOLATION_NO":"9060220","ISSUE_DT":"01/13/2016","CFR_STANDARD_CD":"75.507","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"362.00","CURRENT_ASSESSMENT_AMT":"362.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2016-01-13"},{"SOURCE_ROW_NUMBER":"1881734","VIOLATION_NO":"9055219","ISSUE_DT":"01/11/2016","CFR_STANDARD_CD":"72.630(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"585.00","CURRENT_ASSESSMENT_AMT":"585.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2016-01-11"},{"SOURCE_ROW_NUMBER":"1881733","VIOLATION_NO":"9055218","ISSUE_DT":"01/11/2016","CFR_STANDARD_CD":"75.1719-4(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2016-01-11"},{"SOURCE_ROW_NUMBER":"1881732","VIOLATION_NO":"9055217","ISSUE_DT":"01/08/2016","CFR_STANDARD_CD":"75.380(d)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"362.00","CURRENT_ASSESSMENT_AMT":"362.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2016-01-08"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":5,"firstDate":"2013-11-13","lastDate":"2016-01-05","metrics":{"appeals":0,"decisions":5,"recentRows":0,"decisionPenalty":2766,"originalPenalty":4692},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"371134","VIOLATION_NO":"9010486","DOCKET_NO":"WEVA 2015-0492","DECISION_DT":"01/05/2016","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2473.00","DECISION_PENALTY_AMT":"1236.00","JUDGE_FIRST_NAME":"Jerold","JUDGE_LAST_NAME":"Feldman","sourceDate":"2016-01-05"},{"SOURCE_ROW_NUMBER":"97380","VIOLATION_NO":"6617100","DOCKET_NO":"WEVA 2013-1122","DECISION_DT":"09/25/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Jerold","JUDGE_LAST_NAME":"Feldman","sourceDate":"2015-09-25"},{"SOURCE_ROW_NUMBER":"357792","VIOLATION_NO":"9000472","DOCKET_NO":"WEVA 2014-0844","DECISION_DT":"03/27/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"687.00","DECISION_PENALTY_AMT":"450.00","JUDGE_FIRST_NAME":"Jerold","JUDGE_LAST_NAME":"Feldman","sourceDate":"2015-03-27"},{"SOURCE_ROW_NUMBER":"343418","VIOLATION_NO":"7178868","DOCKET_NO":"WEVA 2013-826","DECISION_DT":"11/13/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"745.00","DECISION_PENALTY_AMT":"500.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2013-11-13"},{"SOURCE_ROW_NUMBER":"97381","VIOLATION_NO":"7208961","DOCKET_NO":"WEVA 2013-826","DECISION_DT":"11/13/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"687.00","DECISION_PENALTY_AMT":"480.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2013-11-13"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":500,"firstDate":"2006-03-05","lastDate":"2016-02-16","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":98,"validSamples":402,"maxConcentration":7.562,"concentrationTotal":301.956},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1597084","CASS_NUM":"58198564","SMP_TAKEN_DT":"2/16/2016","CONC":".691","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ELECTRICIAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2016-02-16"},{"SOURCE_ROW_NUMBER":"1309650","CASS_NUM":"58198441","SMP_TAKEN_DT":"2/16/2016","CONC":".435","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2016-02-16"},{"SOURCE_ROW_NUMBER":"1260730","CASS_NUM":"58198355","SMP_TAKEN_DT":"2/16/2016","CONC":".5","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2016-02-16"},{"SOURCE_ROW_NUMBER":"972933","CASS_NUM":"58198422","SMP_TAKEN_DT":"2/16/2016","CONC":".464","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2016-02-16"},{"SOURCE_ROW_NUMBER":"806145","CASS_NUM":"58198609","SMP_TAKEN_DT":"2/16/2016","CONC":".669","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2016-02-16"},{"SOURCE_ROW_NUMBER":"616093","CASS_NUM":"58198419","SMP_TAKEN_DT":"2/16/2016","CONC":".543","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2016-02-16"},{"SOURCE_ROW_NUMBER":"583160","CASS_NUM":"58198487","SMP_TAKEN_DT":"2/16/2016","CONC":".038","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2016-02-16"},{"SOURCE_ROW_NUMBER":"373023","CASS_NUM":"58198493","SMP_TAKEN_DT":"2/16/2016","CONC":".455","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2016-02-16"},{"SOURCE_ROW_NUMBER":"246158","CASS_NUM":"58198430","SMP_TAKEN_DT":"2/16/2016","CONC":".116","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2016-02-16"},{"SOURCE_ROW_NUMBER":"214965","CASS_NUM":"58198530","SMP_TAKEN_DT":"2/16/2016","CONC":".028","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2016-02-16"},{"SOURCE_ROW_NUMBER":"181915","CASS_NUM":"58198660","SMP_TAKEN_DT":"2/16/2016","CONC":".442","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2016-02-16"},{"SOURCE_ROW_NUMBER":"70379","CASS_NUM":"58198556","SMP_TAKEN_DT":"2/16/2016","CONC":".084","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2016-02-16"}]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":5,"firstDate":"2013-02-22","lastDate":"2014-09-15","metrics":{"decisions":5,"ssChanged":3,"recentRows":0,"decisionPenalty":2766,"proposedPenalty":4692},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"316737","CITATION_NO":"9010486","CITATION_ISSUE_DT":"09/15/2014","DOCKET_NO":"WEVA 2015-0492","DECISION_DT":"01/05/2016","CFR_STANDARD_CODE":"75.1725(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"2473.00","DECISION_PENALTY_AMT":"1236.00","sourceDate":"2014-09-15"},{"SOURCE_ROW_NUMBER":"35758","CITATION_NO":"9000472","CITATION_ISSUE_DT":"02/21/2014","DOCKET_NO":"WEVA 2014-0844","DECISION_DT":"03/27/2015","CFR_STANDARD_CODE":"72.630(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"687.00","DECISION_PENALTY_AMT":"450.00","sourceDate":"2014-02-21"},{"SOURCE_ROW_NUMBER":"143405","CITATION_NO":"7208961","CITATION_ISSUE_DT":"03/06/2013","DOCKET_NO":"WEVA 2013-826","DECISION_DT":"11/13/2013","CFR_STANDARD_CODE":"75.517","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"687.00","DECISION_PENALTY_AMT":"480.00","sourceDate":"2013-03-06"},{"SOURCE_ROW_NUMBER":"314719","CITATION_NO":"7178868","CITATION_ISSUE_DT":"02/27/2013","DOCKET_NO":"WEVA 2013-826","DECISION_DT":"11/13/2013","CFR_STANDARD_CODE":"77.1605(k)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"745.00","DECISION_PENALTY_AMT":"500.00","sourceDate":"2013-02-27"},{"SOURCE_ROW_NUMBER":"13894","CITATION_NO":"6617100","CITATION_ISSUE_DT":"02/22/2013","DOCKET_NO":"WEVA 2013-1122","DECISION_DT":"09/25/2015","CFR_STANDARD_CODE":"90.103(e)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2013-02-22"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":102,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":30,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"2009-09-23","lastDate":"2009-09-23","metrics":{"recentRows":0,"currentOperatorTenures":3,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":44,"firstDate":"2009-12-29","lastDate":"2019-08-12","metrics":{"inspectors":116,"recentRows":0,"onSiteHours":2156,"inspectionHours":3884.25,"inspectionSamples":575},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"299656","EVENT_NO":"6314877","INSPECTION_BEGIN_DT":"08/12/2019","INSPECTION_END_DT":"08/13/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"31.5","SUM_TOTAL_ON_SITE_HOURS":"11","sourceDate":"2019-08-12"},{"SOURCE_ROW_NUMBER":"574334","EVENT_NO":"6315761","INSPECTION_BEGIN_DT":"08/02/2019","INSPECTION_END_DT":"08/02/2019","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.25","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2019-08-02"},{"SOURCE_ROW_NUMBER":"650988","EVENT_NO":"6312819","INSPECTION_BEGIN_DT":"07/03/2019","INSPECTION_END_DT":"07/03/2019","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.25","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2019-07-03"},{"SOURCE_ROW_NUMBER":"462449","EVENT_NO":"6312697","INSPECTION_BEGIN_DT":"03/04/2019","INSPECTION_END_DT":"03/06/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2019-03-04"},{"SOURCE_ROW_NUMBER":"1076807","EVENT_NO":"6312250","INSPECTION_BEGIN_DT":"11/05/2018","INSPECTION_END_DT":"11/06/2018","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11.5","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2018-11-05"},{"SOURCE_ROW_NUMBER":"353929","EVENT_NO":"6314457","INSPECTION_BEGIN_DT":"08/09/2018","INSPECTION_END_DT":"08/13/2018","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"19","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2018-08-09"},{"SOURCE_ROW_NUMBER":"1051837","EVENT_NO":"6311460","INSPECTION_BEGIN_DT":"09/08/2016","INSPECTION_END_DT":"09/08/2016","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2016-09-08"},{"SOURCE_ROW_NUMBER":"278403","EVENT_NO":"6303391","INSPECTION_BEGIN_DT":"04/25/2016","INSPECTION_END_DT":"04/25/2016","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2016-04-25"},{"SOURCE_ROW_NUMBER":"796787","EVENT_NO":"6308873","INSPECTION_BEGIN_DT":"03/28/2016","INSPECTION_END_DT":"03/28/2016","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2016-03-28"},{"SOURCE_ROW_NUMBER":"993944","EVENT_NO":"6308871","INSPECTION_BEGIN_DT":"03/22/2016","INSPECTION_END_DT":"03/22/2016","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2016-03-22"},{"SOURCE_ROW_NUMBER":"1150396","EVENT_NO":"6308870","INSPECTION_BEGIN_DT":"03/16/2016","INSPECTION_END_DT":"03/17/2016","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2016-03-16"},{"SOURCE_ROW_NUMBER":"486345","EVENT_NO":"6308867","INSPECTION_BEGIN_DT":"01/05/2016","INSPECTION_END_DT":"03/02/2016","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"6","SUM_TOTAL_INSP_HOURS":"340.5","SUM_TOTAL_ON_SITE_HOURS":"178.25","sourceDate":"2016-01-05"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":92,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2019-Q3":{"hours":168,"employees":4,"production":0},"2017-Q2":{"hours":0,"employees":0,"production":0},"2017-Q1":{"hours":0,"employees":0,"production":0},"2016-Q4":{"hours":0,"employees":0,"production":0},"2016-Q3":{"hours":200,"employees":2,"production":0},"2016-Q2":{"hours":6489,"employees":21,"production":0},"2016-Q1":{"hours":33397,"employees":67,"production":38884},"2015-Q4":{"hours":35199,"employees":64,"production":63961},"2015-Q3":{"hours":32427,"employees":60,"production":73159},"2015-Q2":{"hours":33064,"employees":57,"production":75498},"2015-Q1":{"hours":32575,"employees":54,"production":62155},"2014-Q4":{"hours":27636,"employees":55,"production":69477}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":14,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2012":{"hours":6878,"employees":37,"production":11040},"2013":{"hours":118951,"employees":52,"production":247246},"2014":{"hours":122149,"employees":56,"production":259578},"2015":{"hours":133265,"employees":59,"production":274773},"2016":{"hours":40086,"employees":42,"production":38884},"2019":{"hours":168,"employees":4,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":55,"firstDate":"2013-04-17","lastDate":"2015-12-15","metrics":{"recentRows":0,"doseOver100":7,"actDoseTotal":3779,"pelDoseTotal":2562},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"265703","EVENT_NO":"6308863","SURVEY_DATE":"12/15/2015","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"058","ACT_DOSE_85":"42","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2015-12-15"},{"SOURCE_ROW_NUMBER":"265702","EVENT_NO":"6308863","SURVEY_DATE":"12/15/2015","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"058","ACT_DOSE_85":"74","PEL_DOSE_90":"46","SURVEY_TYPE":"I","sourceDate":"2015-12-15"},{"SOURCE_ROW_NUMBER":"265701","EVENT_NO":"6308863","SURVEY_DATE":"12/15/2015","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"039","ACT_DOSE_85":"155","PEL_DOSE_90":"131","SURVEY_TYPE":"I","sourceDate":"2015-12-15"},{"SOURCE_ROW_NUMBER":"265670","EVENT_NO":"6295544","SURVEY_DATE":"09/22/2015","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"119","ACT_DOSE_85":"65","PEL_DOSE_90":"28","SURVEY_TYPE":"I","sourceDate":"2015-09-22"},{"SOURCE_ROW_NUMBER":"265669","EVENT_NO":"6295544","SURVEY_DATE":"09/22/2015","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"65","PEL_DOSE_90":"39","SURVEY_TYPE":"I","sourceDate":"2015-09-22"},{"SOURCE_ROW_NUMBER":"265668","EVENT_NO":"6295544","SURVEY_DATE":"09/22/2015","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"85","PEL_DOSE_90":"50","SURVEY_TYPE":"I","sourceDate":"2015-09-22"},{"SOURCE_ROW_NUMBER":"265667","EVENT_NO":"6295544","SURVEY_DATE":"09/22/2015","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"94","PEL_DOSE_90":"77","SURVEY_TYPE":"I","sourceDate":"2015-09-22"},{"SOURCE_ROW_NUMBER":"265666","EVENT_NO":"6295544","SURVEY_DATE":"09/22/2015","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"119","ACT_DOSE_85":"86","PEL_DOSE_90":"53","SURVEY_TYPE":"I","sourceDate":"2015-09-22"},{"SOURCE_ROW_NUMBER":"265665","EVENT_NO":"6295544","SURVEY_DATE":"09/22/2015","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"93","PEL_DOSE_90":"65","SURVEY_TYPE":"I","sourceDate":"2015-09-22"},{"SOURCE_ROW_NUMBER":"265664","EVENT_NO":"6295544","SURVEY_DATE":"09/22/2015","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"62","PEL_DOSE_90":"28","SURVEY_TYPE":"I","sourceDate":"2015-09-22"},{"SOURCE_ROW_NUMBER":"265663","EVENT_NO":"6295544","SURVEY_DATE":"09/22/2015","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"141","PEL_DOSE_90":"128","SURVEY_TYPE":"I","sourceDate":"2015-09-22"},{"SOURCE_ROW_NUMBER":"265662","EVENT_NO":"6295544","SURVEY_DATE":"09/10/2015","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"16","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2015-09-10"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":30,"firstDate":"2013-04-18","lastDate":"2016-02-16","metrics":{"recentRows":0,"voidSamples":3,"maxQuartzPct":7.7,"validSamples":27,"quartzPctTotal":109.7},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"159873","CASSETTE_NO":"58198422","SAMPLE_DT":"02/16/2016","QUARTZ_PCT":"06.5","QUARTZ_MICROGRAMS":"30","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2016-02-16"},{"SOURCE_ROW_NUMBER":"123223","CASSETTE_NO":"58198660","SAMPLE_DT":"02/16/2016","QUARTZ_PCT":"05.8","QUARTZ_MICROGRAMS":"25","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"MMU NOT IN PRODUCING STATUS","sourceDate":"2016-02-16"},{"SOURCE_ROW_NUMBER":"45791","CASSETTE_NO":"58198609","SAMPLE_DT":"02/16/2016","QUARTZ_PCT":"07.7","QUARTZ_MICROGRAMS":"51","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"MMU NOT IN PRODUCING STATUS","sourceDate":"2016-02-16"},{"SOURCE_ROW_NUMBER":"43930","CASSETTE_NO":"58198419","SAMPLE_DT":"02/16/2016","QUARTZ_PCT":"02.9","QUARTZ_MICROGRAMS":"15","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2016-02-16"},{"SOURCE_ROW_NUMBER":"23657","CASSETTE_NO":"58198441","SAMPLE_DT":"02/16/2016","QUARTZ_PCT":"02.9","QUARTZ_MICROGRAMS":"12","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"MMU NOT IN PRODUCING STATUS","sourceDate":"2016-02-16"},{"SOURCE_ROW_NUMBER":"34705","CASSETTE_NO":"58160603","SAMPLE_DT":"01/26/2016","QUARTZ_PCT":"01.9","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2016-01-26"},{"SOURCE_ROW_NUMBER":"22489","CASSETTE_NO":"58160458","SAMPLE_DT":"01/26/2016","QUARTZ_PCT":"03.3","QUARTZ_MICROGRAMS":"5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2016-01-26"},{"SOURCE_ROW_NUMBER":"150528","CASSETTE_NO":"58160412","SAMPLE_DT":"11/03/2015","QUARTZ_PCT":"01.1","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-11-03"},{"SOURCE_ROW_NUMBER":"93713","CASSETTE_NO":"58160491","SAMPLE_DT":"11/03/2015","QUARTZ_PCT":"03.4","QUARTZ_MICROGRAMS":"9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-11-03"},{"SOURCE_ROW_NUMBER":"11983","CASSETTE_NO":"58160282","SAMPLE_DT":"09/10/2015","QUARTZ_PCT":"03.8","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-09-10"},{"SOURCE_ROW_NUMBER":"8397","CASSETTE_NO":"58160295","SAMPLE_DT":"09/10/2015","QUARTZ_PCT":"03.0","QUARTZ_MICROGRAMS":"10","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-09-10"},{"SOURCE_ROW_NUMBER":"137044","CASSETTE_NO":"58160507","SAMPLE_DT":"08/26/2015","QUARTZ_PCT":"02.7","QUARTZ_MICROGRAMS":"15","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-08-26"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":128,"firstDate":"2012-06-12","lastDate":"2016-02-23","metrics":{"ss":37,"amountDue":51177,"contested":0,"amountPaid":51177,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":53103},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2958411","VIOLATION_NO":"9060226","VIOLATION_ISSUE_DT":"02/23/2016","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/24/2016","PROPOSED_PENALTY":"362","AMOUNT_DUE":"362","AMOUNT_PAID":"362","CONTESTED_IND":"N","sourceDate":"2016-02-23"},{"SOURCE_ROW_NUMBER":"2958410","VIOLATION_NO":"9060225","VIOLATION_ISSUE_DT":"02/22/2016","SIG_SUB":"Y","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/23/2016","PROPOSED_PENALTY":"362","AMOUNT_DUE":"362","AMOUNT_PAID":"362","CONTESTED_IND":"N","sourceDate":"2016-02-22"},{"SOURCE_ROW_NUMBER":"2958404","VIOLATION_NO":"9055490","VIOLATION_ISSUE_DT":"02/17/2016","SIG_SUB":"N","PART_SECTION":"75.518-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/17/2016","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2016-02-17"},{"SOURCE_ROW_NUMBER":"2958403","VIOLATION_NO":"9055489","VIOLATION_ISSUE_DT":"02/17/2016","SIG_SUB":"N","PART_SECTION":"75.900-4","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/17/2016","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2016-02-17"},{"SOURCE_ROW_NUMBER":"2958409","VIOLATION_NO":"9060224","VIOLATION_ISSUE_DT":"02/10/2016","SIG_SUB":"Y","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"02/10/2016","PROPOSED_PENALTY":"540","AMOUNT_DUE":"540","AMOUNT_PAID":"540","CONTESTED_IND":"N","sourceDate":"2016-02-10"},{"SOURCE_ROW_NUMBER":"2958408","VIOLATION_NO":"9060223","VIOLATION_ISSUE_DT":"01/27/2016","SIG_SUB":"N","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/01/2016","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2016-01-27"},{"SOURCE_ROW_NUMBER":"2958407","VIOLATION_NO":"9060222","VIOLATION_ISSUE_DT":"01/20/2016","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/25/2016","PROPOSED_PENALTY":"1203","AMOUNT_DUE":"1203","AMOUNT_PAID":"1203","CONTESTED_IND":"N","sourceDate":"2016-01-20"},{"SOURCE_ROW_NUMBER":"2958406","VIOLATION_NO":"9060221","VIOLATION_ISSUE_DT":"01/19/2016","SIG_SUB":"Y","PART_SECTION":"75.364(b)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"01/25/2016","PROPOSED_PENALTY":"162","AMOUNT_DUE":"162","AMOUNT_PAID":"162","CONTESTED_IND":"N","sourceDate":"2016-01-19"},{"SOURCE_ROW_NUMBER":"2958405","VIOLATION_NO":"9060220","VIOLATION_ISSUE_DT":"01/13/2016","SIG_SUB":"N","PART_SECTION":"75.507","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"9","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/13/2016","PROPOSED_PENALTY":"362","AMOUNT_DUE":"362","AMOUNT_PAID":"362","CONTESTED_IND":"N","sourceDate":"2016-01-13"},{"SOURCE_ROW_NUMBER":"2958402","VIOLATION_NO":"9055219","VIOLATION_ISSUE_DT":"01/11/2016","SIG_SUB":"Y","PART_SECTION":"72.630(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/12/2016","PROPOSED_PENALTY":"585","AMOUNT_DUE":"585","AMOUNT_PAID":"585","CONTESTED_IND":"N","sourceDate":"2016-01-11"},{"SOURCE_ROW_NUMBER":"2958401","VIOLATION_NO":"9055218","VIOLATION_ISSUE_DT":"01/11/2016","SIG_SUB":"N","PART_SECTION":"75.1719-4(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/12/2016","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2016-01-11"},{"SOURCE_ROW_NUMBER":"2958400","VIOLATION_NO":"9055217","VIOLATION_ISSUE_DT":"01/08/2016","SIG_SUB":"Y","PART_SECTION":"75.380(d)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/11/2016","PROPOSED_PENALTY":"362","AMOUNT_DUE":"362","AMOUNT_PAID":"362","CONTESTED_IND":"N","sourceDate":"2016-01-08"}]}],"safety":{"href":"/api/v1/mines/4609353/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609353/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1725","heading":"Machinery and equipment; operation and maintenance.","id":"75.1725","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1725","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","heading":"Electric equipment and circuits; overload and short circuit protection; minimum requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.518-1","part":"75","subchapter":"O","subpart":"F","id":"75.518-1","citation":"30 CFR 75.518-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Testing, examination, and maintenance of circuit breakers; record.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-J/section-75.900-4","part":"75","subchapter":"O","subpart":"J","id":"75.900-4","citation":"30 CFR 75.900-4","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.364","heading":"Weekly examination.","id":"75.364","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.364","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Worked-out areas. (1) At least every 7 days, a certified person shall examine unsealed worked-out areas where no pillars have been recovered by traveling to the area of deepest penetration; measuring methane and oxygen concentrations and air quantities and making tests to determine if the air is moving in the proper direction in the area. The locations of measurement points where tests and measurements will be performed shall be included in the mine ventilation plan and shall be adequate in number and location to assure ventilation and air quality in the area. Air quantity measurements shall also be made where the air enters and leaves the worked-out area. An alternative method of evaluating the ventilation of the area may be approved in the ventilation plan.\n\n(2) At least every 7 days, a certified person shall evaluate the effectiveness of bleeder systems required by § 75.334 as follows:\n\n(i) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in its proper direction shall be made where air enters the worked-out area.\n\n(ii) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in the proper direction shall be made immediately before the air enters a return split of air.\n\n(iii) At least one entry of each set of bleeder entries used as part of a bleeder system under § 75.334 shall be traveled in its entirety. Measurements of methane and oxygen concentrations and air quantities and a test to determine if the air is moving in the proper direction shall be made at the measurement point locations specified in the mine ventilation plan to determine the effectiveness of the bleeder system.\n\n(iv) In lieu of the requirements of paragraphs (a)(2)(i) and (iii) of this section, an alternative method of evaluation may be specified in the ventilation plan provided the alternative method results in proper evaluation of the effectiveness of the bleeder system.\n\n(b) Hazardous conditions and violations of mandatory health or safety standards. At least every 7 days, an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(8) of this section shall be made by a certified person designated by the operator at the following locations:\n\n(1) In at least one entry of each intake air course, in its entirety, so that the entire air course is traveled.\n\n(2) In at least one entry of each return air course, in its entirety, so that the entire air course is traveled.\n\n(3) In each longwall or shortwall travelway in its entirety, so that the entire travelway is traveled.\n\n(4) At each seal along return and bleeder air courses and at each seal along intake air courses not examined under § 75.360(b)(5).\n\n(5) In each escapeway so that the entire escapeway is traveled.\n\n(6) On each working section not examined under § 75.360(b)(3) during the previous 7 days.\n\n(7) At each water pump not examined during a preshift examination conducted during the previous 7 days.\n\n(8) Weekly examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust; and\n\n(iv) § 75.1403—maintenance of off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) Measurements and tests. At least every 7 days, a certified person shall—\n\n(1) Determine the volume of air entering the main intakes and in each intake split;\n\n(2) Determine the volume of air and test for methane in the last open crosscut in any pair or set of developing entries or rooms, in the return of each split of air immediately before it enters the main returns, and where the air leaves the main returns; and\n\n(3) Test for methane in the return entry nearest each set of seals immediately after the air passes the seals.\n\n(d) Hazardous conditions shall be corrected immediately. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Any violation of the nine mandatory health or safety standards found during a weekly examination shall be corrected.\n\n(e) The weekly examination may be conducted at the same time as the preshift or on-shift examinations.\n\n(f) (1) The weekly examination is not required during any 7 day period in which no one enters any underground area of the mine.\n\n(2) Except for certified persons required to make examinations, no one shall enter any underground area of the mine if a weekly examination has not been completed within the previous 7 days.\n\n(g) Certification. The person making the weekly examinations shall certify by initials, date, and the time that the examination was made. Certifications and times shall appear at enough locations to show that the entire area has been examined.\n\n(h) Recordkeeping. At the completion of any shift during which a portion of a weekly examination is conducted, a record of the results of each weekly examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards found during each examination and their locations, the corrective action taken, and the results and location of air and methane measurements, shall be made. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the person making the examination or a person designated by the operator. If made by a person other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(i) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 77 FR 20715, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","heading":"Power connection points.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.507","part":"75","subchapter":"O","subpart":"F","id":"75.507","citation":"30 CFR 75.507","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 72.630","heading":"Drill dust control at underground areas of underground mines.","id":"72.630","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-72/subpart-E/section-72.630","part":"72","partHeading":"PART 72—HEALTH STANDARDS FOR COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Miscellaneous","text":"(a) Dust resulting from drilling in rock shall be controlled by use of permissible dust collectors, or by water, or water with a wetting agent, or by ventilation, or by any other method or device approved by the Secretary that is as effective in controlling the dust.\n\n(b) Dust collectors. Dust collectors shall be maintained in permissible and operating condition. Dust collectors approved under Part 33—Dust Collectors for Use in Connection with Rock Drilling in Coal Mines of this title or under Bureau of Mines Schedule 25B are permissible dust collectors for the purpose of this section.\n\n(c) Water control. Water used to control dust from drilling rock shall be applied through a hollow drill steel or stem or by the flooding of vertical drill holes in the floor.\n\n(d) Ventilation control. To adequately control dust from drilling rock, the air current shall be so directed that the dust is readily dispersed and carried away from the drill operator or any other miners in the area.","occurrenceCount":1},{"chapter":"I","heading":"Mining machines, cap lamps; requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1719-4","part":"75","subchapter":"O","subpart":"R","id":"75.1719-4","citation":"30 CFR 75.1719-4","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.380","heading":"Escapeways; bituminous and lignite mines.","id":"75.380","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.380","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Except in situations addressed in § 75.381, § 75.385 and § 75.386, at least two separate and distinct travelable passageways shall be designated as escapeways and shall meet the requirements of this section.\n\n(b) (1) Escapeways shall be provided from each working section, and each area where mechanized mining equipment is being installed or removed, continuous to the surface escape drift opening or continuous to the escape shaft or slope facilities to the surface.\n\n(2) During equipment installation, these escapeways shall begin at the projected location for the section loading point. During equipment removal, they shall begin at the location of the last loading point.\n\n(c) The two separate and distinct escapeways required by this section shall not end at a common shaft, slope, or drift opening, except that multiple compartment shafts or slopes separated by walls constructed of noncombustible material may be used as separate and distinct passageways.\n\n(d) Each escapeway shall be—\n\n(1) Maintained in a safe condition to always assure passage of anyone, including disabled persons;\n\n(2) Clearly marked to show the route and direction of travel to the surface;\n\n(3) Maintained to at least a height of 5 feet from the mine floor to the mine roof, excluding the thickness of any roof support, except that the escapeways shall be maintained to at least the height of the coalbed, excluding the thickness of any roof support, where the coalbed is less than 5 feet. In areas of mines where escapeways pass through doors, the height may be less than 5 feet, provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. In areas of mines developed before November 16, 1992, where escapeways pass over or under overcasts or undercasts, the height may be less than 5 feet provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient height is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(4) Maintained at least 6 feet wide except—\n\n(i) Where necessary supplemental roof support is installed, the escapeway shall not be less than 4 feet wide; or\n\n(ii) Where the route of travel passes through doors or other permanent ventilation controls, the escapeway shall be at least 4 feet wide to enable miners to escape quickly in an emergency, or\n\n(iii) Where the alternate escapeway passes through doors or other permanent ventilation controls or where supplemental roof support is required and sufficient width is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher, or\n\n(iv) Where mobile equipment near working sections, and other equipment essential to the ongoing operation of longwall sections, is necessary during normal mining operations, such as material cars containing rock dust or roof control supplies, or is to be used for the evacuation of miners off the section in the event of an emergency. In any instance, escapeways shall be of sufficient width to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(5) Located to follow the most direct, safe and practical route to the nearest mine opening suitable for the safe evacuation of miners; and\n\n(6) Provided with ladders, stairways, ramps, or similar facilities where the escapeways cross over obstructions.\n\n(7) Provided with a continuous, durable directional lifeline or equivalent device that shall be—\n\n(i) Installed and maintained throughout the entire length of each escapeway as defined in paragraph (b)(1) of this section;\n\n(ii) Flame-resistant in accordance with the requirements of part 18 of this chapter upon replacement of existing lifelines; but in no case later than June 15, 2009;\n\n(iii) Marked with a reflective material every 25 feet;\n\n(iv) Located in such a manner for miners to use effectively to escape;\n\n(v) Equipped with one directional indicator cone securely attached to the lifeline, signifying the route of escape, placed at intervals not exceeding 100 feet. Cones shall be installed so that the tapered section points inby;\n\n(vi) Equipped with one sphere securely attached to the lifeline at each intersection where personnel doors are installed in adjacent crosscuts;\n\n(vii) Equipped with two securely attached cones, installed consecutively with the tapered section pointing inby, to signify an attached branch line is immediately ahead.\n\n(A) A branch line leading from the lifeline to an SCSR cache will be marked with four cones with the base sections in contact to form two diamond shapes. The cones must be placed within reach of the lifeline.\n\n(B) A branch line leading from the lifeline to a refuge alternative will be marked with a rigid spiraled coil at least eight inches in length. The spiraled coil must be placed within reach of the lifeline (see Illustration 1 below).\n\n(e) Surface openings shall be adequately protected to prevent surface fires, fumes, smoke, and flood water from entering the mine.\n\n(f) Primary escapeway. (1) One escapeway that is ventilated with intake air shall be designated as the primary escapeway. The primary escapeway shall have a higher ventilation pressure than the belt entry unless the mine operator submits an alternative in the mine ventilation plan to protect the integrity of the primary escapeway, based on mine specific conditions, which is approved by the district manager.\n\n(2) Paragraphs (f)(3) through (f)(7) of this section apply as follows:\n\n(i) To all areas of a primary escapeway developed on or after November 16, 1992;\n\n(ii) Effective as of June 10, 1997, to all areas of a primary escapeway developed between March 30, 1970 and November 16, 1992; and\n\n(iii) Effective as of June 10, 1997, to all areas of the primary escapeway developed prior to March 30, 1970 where separation of the belt and trolley haulage entries from the primary escapeway existed prior to November 16, 1992.\n\n(3) The following equipment is not permitted in the primary escapeway:\n\n(i) Mobile equipment hauling coal except for hauling coal incidental to cleanup or maintenance of the primary escapeway.\n\n(ii) Compressors, except—\n\n(A) Compressors necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Compressors that are components of equipment such as locomotives and rock dusting machines; and\n\n(C) Compressors of less than five horsepower.\n\n(iii) Underground transformer stations, battery charging stations, substations, and rectifiers except—\n\n(A) Where necessary to maintain the escapeway in safe, travelable condition; and\n\n(B) Battery charging stations and rectifiers and power centers with transformers that are either dry-type or contain nonflammable liquid, provided they are located on or near a working section and are moved as the section advances or retreats.\n\n(iv) Water pumps, except—\n\n(A) Water pumps necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Submersible pumps;\n\n(C) Permissible pumps and associated permissible switchgear;\n\n(D) Pumps located on or near a working section that are moved as the section advances or retreats;\n\n(E) Pumps installed in anthracite mines; and\n\n(F) Small portable pumps.\n\n(4) Mobile equipment operated in the primary escapeway, except for continuous miners and as provided in paragraphs (f)(5), (f)(6), and (f)(7) of this section, shall be equipped with a fire suppression system installed according to §§ 75.1107-3 through 75.1107-16 that is—\n\n(i) Manually operated and attended continuously by a person trained in the systems function and use, or\n\n(ii) A multipurpose dry chemical type capable of both automatic and manual activation.\n\n(5) Personnel carriers and small mobile equipment designed and used only for carrying people and small hand tools may be operated in primary escapeways if—\n\n(i) The equipment is provided with a multipurpose dry chemical type fire suppression system capable of both automatic and manual activation, and the suppression system is suitable for the intended application and is listed or approved by a nationally recognized independent testing laboratory, or,\n\n(ii) Battery powered and provided with two 10 pound multipurpose dry chemical portable fire extinguishers.\n\n(6) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment not provided with a fire suppression system may operate in the primary escapeway if no one is inby except those persons directly engaged in using or moving the equipment.\n\n(7) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment designated and used only as emergency vehicles or ambulances, may be operated in the primary escapeway without fire suppression systems.\n\n(g) Except where separation of belt and trolley haulage entries from designated escapeways did not exist before November 15, 1992, and except as provided in § 75.350(c), the primary escapeway must be separated from belt and trolley haulage entries for its entire length, to and including the first connecting crosscut outby each loading point except when a greater or lesser distance for this separation is specified and approved in the mine ventilation plan and does not pose a hazard to miners.\n\n(h) Alternate escapeway. One escapeway shall be designated as the alternate escapeway. The alternate escapeway shall be separated from the primary escapeway for its entire length, except that the alternate and primary escapeways may be ventilated from a common intake air shaft or slope opening.\n\n(i) Mechanical escape facilities shall be provided and maintained for—\n\n(1) Each shaft that is part of a designated escapeway and is greater than 50 feet in depth; and\n\n(2) Each slope from the coal seam to the surface that is part of a designated escapeway and is inclined more than 9 degrees from the horizontal.\n\n(j) Within 30 minutes after mine personnel on the surface have been notified of an emergency requiring evacuation, mechanical escape facilities provided under paragraph (i) of this section shall be operational at the bottom of shaft and slope openings that are part of escapeways.\n\n(k) Except where automatically activated hoisting equipment is used, the bottom of each shaft or slope opening that is part of a designated escapeway shall be equipped with a means of signaling a surface location where a person is always on duty when anyone is underground. When the signal is activated or the evacuation of persons underground is necessary, the person shall assure that mechanical escape facilities are operational as required by paragraph (j) of this section.\n\n(l)(1) Stairways or mechanical escape facilities shall be installed in shafts that are part of the designated escapeways and that are 50 feet or less in depth, except ladders may be used in shafts that are part of the designated escapeways and that are 5 feet or less in depth.\n\n(2) Stairways shall be constructed of concrete or metal, set on an angle not to exceed 45 degrees from the horizontal, and equipped on the open side with handrails. In addition, landing platforms that are at least 2 feet by 4 feet shall be installed at intervals not to exceed 20 vertical feet on the stairways and equipped on the open side with handrails.\n\n(3) Ladders shall be constructed of metal, anchored securely, and set on an angle not to exceed 60 degrees from the horizontal.\n\n(m) A travelway designed to prevent slippage shall be provided in slope and drift openings that are part of designated escapeways, unless mechanical escape facilities are installed.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 69 FR 17530, Apr. 2, 2004; 71 FR 12269, Mar. 9, 2006; 71 FR 71452, Dec. 8, 2006; 73 FR 80613, Dec. 31, 2008]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609353","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}