{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4609343","name":"Workman Branch Deep Mine","status":"Abandoned","status_date":"2026-06-11","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Boone","nearest_town":"Wharton","operator_id":"0141655","operator_name":"Rockwell Mining LLC","controller_id":"0158381","controller_name":"Sev.en Global Investments a.s.","district":"C04","office":"Madison WV Field Office","employees":0,"latitude":37.887778,"longitude":-81.643611},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":863},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609343","name":"Workman Branch Deep Mine"},"operator":{"type":"operator","id":"0141655","name":"Rockwell Mining LLC"},"controller":{"type":"controller","id":"0158381","name":"Sev.en Global Investments a.s."},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"mine","id":"4609343","name":"Workman Branch Deep Mine"},"validFrom":"2001-04-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609343|C15833|2001-04-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24609","name":"Hillside Mining Company"},"object":{"type":"mine","id":"4609343","name":"Workman Branch Deep Mine"},"validFrom":"2009-06-01","validTo":"2011-08-01","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609343|P24609|2009-06-01|2011-08-01"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"operator","id":"P24609","name":"Hillside Mining Company"},"validFrom":"2009-06-01","validTo":"2011-08-01","current":false,"derived":true,"evidenceMineId":"4609343","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609343|P24609|2009-06-01|C15833|2001-04-01|96988"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0100265","name":"Michael  Day"},"object":{"type":"mine","id":"4609343","name":"Workman Branch Deep Mine"},"validFrom":"2011-05-31","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609343|0100265|2011-05-31|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0118288","name":"Lago Mining, LLC"},"object":{"type":"mine","id":"4609343","name":"Workman Branch Deep Mine"},"validFrom":"2011-08-02","validTo":"2013-01-16","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609343|0118288|2011-08-02|2013-01-16"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0100265","name":"Michael  Day"},"object":{"type":"operator","id":"0118288","name":"Lago Mining, LLC"},"validFrom":"2011-08-02","validTo":"2013-01-16","current":false,"derived":true,"evidenceMineId":"4609343","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609343|0118288|2011-08-02|0100265|2011-05-31|16744"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24609","name":"Hillside Mining Company"},"object":{"type":"mine","id":"4609343","name":"Workman Branch Deep Mine"},"validFrom":"2013-01-17","validTo":"2018-06-03","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609343|P24609|2013-01-17|2018-06-03"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"operator","id":"P24609","name":"Hillside Mining Company"},"validFrom":"2013-01-17","validTo":"2018-06-03","current":false,"derived":true,"evidenceMineId":"4609343","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609343|P24609|2013-01-17|C15833|2001-04-01|96989"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0109461","name":"Blackhawk Mining LLC"},"object":{"type":"mine","id":"4609343","name":"Workman Branch Deep Mine"},"validFrom":"2015-10-26","validTo":"2020-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609343|0109461|2015-10-26|2020-05-31"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0141655","name":"Rockwell Mining LLC"},"object":{"type":"mine","id":"4609343","name":"Workman Branch Deep Mine"},"validFrom":"2018-06-04","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609343|0141655|2018-06-04|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0109461","name":"Blackhawk Mining LLC"},"object":{"type":"operator","id":"0141655","name":"Rockwell Mining LLC"},"validFrom":"2018-06-04","validTo":"2020-05-31","current":false,"derived":true,"evidenceMineId":"4609343","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609343|0141655|2018-06-04|0109461|2015-10-26|19935"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0158381","name":"Sev.en Global Investments a.s."},"object":{"type":"mine","id":"4609343","name":"Workman Branch Deep Mine"},"validFrom":"2020-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609343|0158381|2020-06-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0158381","name":"Sev.en Global Investments a.s."},"object":{"type":"operator","id":"0141655","name":"Rockwell Mining LLC"},"validFrom":"2020-06-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609343","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609343|0141655|2018-06-04|0158381|2020-06-01|32876"}}],"coverage":{"historyRecords":5,"edgeCount":13,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":10,"firstDate":"2011-07-25","lastDate":"2012-09-11","metrics":{"daysLost":25,"injuries":10,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"102759","DOCUMENT_NO":"220122620040","ACCIDENT_DT":"09/11/2012","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was bolting top. When he reached to get the drill steel, it fell, striking his left ring finger.","sourceDate":"2012-09-11"},{"SOURCE_ROW_NUMBER":"85749","DOCUMENT_NO":"220122440019","ACCIDENT_DT":"08/27/2012","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was assisting in pulling a steel beam. As the scoop operator pulled it, the beam dug in, swung around, and struck employee in the left leg, knocking him down and pinning him to the ground.","sourceDate":"2012-08-27"},{"SOURCE_ROW_NUMBER":"64129","DOCUMENT_NO":"220121600005","ACCIDENT_DT":"06/05/2012","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was putting rock dust in duster on scoop. When he stepped down from scoop, he twisted his Left ankle.","sourceDate":"2012-06-05"},{"SOURCE_ROW_NUMBER":"4109","DOCUMENT_NO":"220121180019","ACCIDENT_DT":"04/19/2012","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was helping install rib boards. He was feeding the drill steel through a hole in the rib board when his glove got caught on the steel and twisted his right hand.","sourceDate":"2012-04-19"},{"SOURCE_ROW_NUMBER":"236385","DOCUMENT_NO":"220120940032","ACCIDENT_DT":"02/24/2012","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee lifted an oxygen cylinder when he felt pain in his left bicep area. Employee did not miss work or receive medical treatment until 4-3-2012, when he underwent surgery to repair a bicep tear. Employee stated he has had a similar problem in the past.","sourceDate":"2012-02-24"},{"SOURCE_ROW_NUMBER":"167518","DOCUMENT_NO":"220120090031","ACCIDENT_DT":"01/04/2012","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"Employee was helping to put up rib boards. The drill steel came out of the chuck. Employee told operator to pull the head back and he would retrieve the steel. The chain track caught the employee's right hand.","sourceDate":"2012-01-04"},{"SOURCE_ROW_NUMBER":"171791","DOCUMENT_NO":"220112940006","ACCIDENT_DT":"10/18/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Roof bolter helper, Rock bolter helper, Pinner helper","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"Employee was riding on mantrip. When he raised up to move plug he was sitting on, he struck his head on a belt cross-under the mantrip was crossing under.","sourceDate":"2011-10-18"},{"SOURCE_ROW_NUMBER":"85748","DOCUMENT_NO":"220112920016","ACCIDENT_DT":"09/28/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"22","NARRATIVE":"Employee was walking through crosscut from belt to roadway, up an incline, when he slipped and fell on his right side, pulling muscle in his right leg.","sourceDate":"2011-09-28"},{"SOURCE_ROW_NUMBER":"154594","DOCUMENT_NO":"220112550013","ACCIDENT_DT":"08/31/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was taking a joint of water line out when he slipped and fell, grabbing the guard on the #3 belt head. This resulted in a laceration to his left middle finger, requiring sutures.","sourceDate":"2011-08-31"},{"SOURCE_ROW_NUMBER":"240717","DOCUMENT_NO":"220112100015","ACCIDENT_DT":"07/25/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was walking behind the scoop when a piece of rock fell and struck employee in the right shoulder, head and arm, resulting in a fractured arm. The rock measured approx. 3' X 3' X 6\" thick.","sourceDate":"2011-07-25"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2026-06-11","lastDate":"2026-06-11","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":47,"firstDate":"2010-12-21","lastDate":"2014-05-21","metrics":{"ss":20,"delinquent":47,"recentRows":0,"paidPenalty":14316,"proposedPenalty":14316,"currentAssessment":14316},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1864672","VIOLATION_NO":"9003288","ISSUE_DT":"05/21/2014","CFR_STANDARD_CD":"75.1711","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"585.00","CURRENT_ASSESSMENT_AMT":"585.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-05-21"},{"SOURCE_ROW_NUMBER":"1837535","VIOLATION_NO":"8125040","ISSUE_DT":"08/02/2012","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1111.00","CURRENT_ASSESSMENT_AMT":"1111.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-08-02"},{"SOURCE_ROW_NUMBER":"1837534","VIOLATION_NO":"8125039","ISSUE_DT":"08/02/2012","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"585.00","CURRENT_ASSESSMENT_AMT":"585.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-08-02"},{"SOURCE_ROW_NUMBER":"1837533","VIOLATION_NO":"8125038","ISSUE_DT":"08/01/2012","CFR_STANDARD_CD":"77.1103(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-08-01"},{"SOURCE_ROW_NUMBER":"1837532","VIOLATION_NO":"8125037","ISSUE_DT":"07/30/2012","CFR_STANDARD_CD":"75.904","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-07-30"},{"SOURCE_ROW_NUMBER":"1837531","VIOLATION_NO":"8125035","ISSUE_DT":"07/23/2012","CFR_STANDARD_CD":"75.1103-4(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-07-23"},{"SOURCE_ROW_NUMBER":"1837530","VIOLATION_NO":"8125034","ISSUE_DT":"07/11/2012","CFR_STANDARD_CD":"75.1714-6","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-07-11"},{"SOURCE_ROW_NUMBER":"1837529","VIOLATION_NO":"8125033","ISSUE_DT":"07/11/2012","CFR_STANDARD_CD":"75.701","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"150.00","CURRENT_ASSESSMENT_AMT":"150.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-07-11"},{"SOURCE_ROW_NUMBER":"1837527","VIOLATION_NO":"8151233","ISSUE_DT":"06/11/2012","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"745.00","CURRENT_ASSESSMENT_AMT":"745.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-06-11"},{"SOURCE_ROW_NUMBER":"1837526","VIOLATION_NO":"8151226","ISSUE_DT":"05/30/2012","CFR_STANDARD_CD":"75.1100-2(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-05-30"},{"SOURCE_ROW_NUMBER":"1837525","VIOLATION_NO":"8151225","ISSUE_DT":"05/30/2012","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"745.00","CURRENT_ASSESSMENT_AMT":"745.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-05-30"},{"SOURCE_ROW_NUMBER":"1837524","VIOLATION_NO":"8151224","ISSUE_DT":"05/29/2012","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-05-29"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":2,"firstDate":"2012-10-09","lastDate":"2013-06-28","metrics":{"appeals":0,"decisions":2,"recentRows":0,"decisionPenalty":100,"originalPenalty":200},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"322536","VIOLATION_NO":"9969326","DOCKET_NO":"WEVA 2012-1008","DECISION_DT":"06/28/2013","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2013-06-28"},{"SOURCE_ROW_NUMBER":"318683","VIOLATION_NO":"8133233","DOCKET_NO":"WEVA 2012-730","DECISION_DT":"10/09/2012","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2012-10-09"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":181,"firstDate":"2011-06-21","lastDate":"2012-08-15","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":44,"validSamples":137,"maxConcentration":8.837,"concentrationTotal":119.706},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1303906","CASS_NUM":"57966672","SMP_TAKEN_DT":"8/15/2012","CONC":".173","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-08-15"},{"SOURCE_ROW_NUMBER":"506072","CASS_NUM":"57966467","SMP_TAKEN_DT":"8/15/2012","CONC":".044","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-08-15"},{"SOURCE_ROW_NUMBER":"313260","CASS_NUM":"51178359","SMP_TAKEN_DT":"8/10/2012","CONC":".11","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-08-10"},{"SOURCE_ROW_NUMBER":"1610386","CASS_NUM":"51188883","SMP_TAKEN_DT":"8/9/2012","CONC":".714","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-08-09"},{"SOURCE_ROW_NUMBER":"1163549","CASS_NUM":"51178326","SMP_TAKEN_DT":"8/9/2012","CONC":".131","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-08-09"},{"SOURCE_ROW_NUMBER":"365523","CASS_NUM":"51179700","SMP_TAKEN_DT":"8/8/2012","CONC":".379","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-08-08"},{"SOURCE_ROW_NUMBER":"274168","CASS_NUM":"51178278","SMP_TAKEN_DT":"8/8/2012","CONC":".15","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-08-08"},{"SOURCE_ROW_NUMBER":"1565824","CASS_NUM":"51157202","SMP_TAKEN_DT":"8/3/2012","CONC":".698","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-08-03"},{"SOURCE_ROW_NUMBER":"526381","CASS_NUM":"51156833","SMP_TAKEN_DT":"8/3/2012","CONC":".102","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-08-03"},{"SOURCE_ROW_NUMBER":"428471","CASS_NUM":"51157220","SMP_TAKEN_DT":"8/3/2012","CONC":".255","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-08-03"},{"SOURCE_ROW_NUMBER":"104402","CASS_NUM":"51157222","SMP_TAKEN_DT":"8/3/2012","CONC":".087","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-08-03"},{"SOURCE_ROW_NUMBER":"1531556","CASS_NUM":"51186794","SMP_TAKEN_DT":"8/2/2012","CONC":".291","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-08-02"}]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":2,"firstDate":"2011-11-29","lastDate":"2012-01-19","metrics":{"decisions":2,"ssChanged":2,"recentRows":0,"decisionPenalty":100,"proposedPenalty":200},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"15016","CITATION_NO":"9969326","CITATION_ISSUE_DT":"01/19/2012","DOCKET_NO":"WEVA 2012-1008","DECISION_DT":"06/28/2013","CFR_STANDARD_CODE":"70.207(a)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2012-01-19"},{"SOURCE_ROW_NUMBER":"183531","CITATION_NO":"8133233","CITATION_ISSUE_DT":"11/29/2011","DOCKET_NO":"WEVA 2012-730","DECISION_DT":"10/09/2012","CFR_STANDARD_CODE":"50.30(a)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":".00","sourceDate":"2011-11-29"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":377,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":70,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":5,"firstDate":"2009-06-01","lastDate":"2018-06-04","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":3},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":29,"firstDate":"2010-12-13","lastDate":"2023-06-29","metrics":{"inspectors":51,"recentRows":6,"onSiteHours":699.75,"inspectionHours":1116.75,"inspectionSamples":145},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1100389","EVENT_NO":"6320291","INSPECTION_BEGIN_DT":"06/29/2023","INSPECTION_END_DT":"06/29/2023","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2023-06-29"},{"SOURCE_ROW_NUMBER":"620455","EVENT_NO":"6318749","INSPECTION_BEGIN_DT":"03/29/2023","INSPECTION_END_DT":"03/29/2023","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.25","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2023-03-29"},{"SOURCE_ROW_NUMBER":"164908","EVENT_NO":"6318735","INSPECTION_BEGIN_DT":"12/28/2022","INSPECTION_END_DT":"12/28/2022","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2022-12-28"},{"SOURCE_ROW_NUMBER":"734941","EVENT_NO":"6319758","INSPECTION_BEGIN_DT":"09/30/2022","INSPECTION_END_DT":"09/30/2022","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.25","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2022-09-30"},{"SOURCE_ROW_NUMBER":"555854","EVENT_NO":"6315633","INSPECTION_BEGIN_DT":"12/22/2021","INSPECTION_END_DT":"12/22/2021","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2021-12-22"},{"SOURCE_ROW_NUMBER":"520995","EVENT_NO":"6314850","INSPECTION_BEGIN_DT":"06/25/2021","INSPECTION_END_DT":"06/25/2021","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2021-06-25"},{"SOURCE_ROW_NUMBER":"169544","EVENT_NO":"6316491","INSPECTION_BEGIN_DT":"12/31/2020","INSPECTION_END_DT":"12/31/2020","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.75","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2020-12-31"},{"SOURCE_ROW_NUMBER":"73894","EVENT_NO":"6313490","INSPECTION_BEGIN_DT":"04/01/2020","INSPECTION_END_DT":"04/01/2020","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.25","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2020-04-01"},{"SOURCE_ROW_NUMBER":"864998","EVENT_NO":"6314456","INSPECTION_BEGIN_DT":"08/07/2018","INSPECTION_END_DT":"08/07/2018","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"13.5","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2018-08-07"},{"SOURCE_ROW_NUMBER":"886443","EVENT_NO":"6303129","INSPECTION_BEGIN_DT":"05/21/2014","INSPECTION_END_DT":"06/16/2014","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"7.25","sourceDate":"2014-05-21"},{"SOURCE_ROW_NUMBER":"1094495","EVENT_NO":"6299009","INSPECTION_BEGIN_DT":"08/20/2013","INSPECTION_END_DT":"08/20/2013","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.25","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2013-08-20"},{"SOURCE_ROW_NUMBER":"671011","EVENT_NO":"6302001","INSPECTION_BEGIN_DT":"02/15/2013","INSPECTION_END_DT":"03/07/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.75","SUM_TOTAL_ON_SITE_HOURS":".75","sourceDate":"2013-02-15"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":52,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2012-Q3":{"hours":40418,"employees":85,"production":47771},"2012-Q2":{"hours":43389,"employees":79,"production":72628},"2012-Q1":{"hours":40602,"employees":59,"production":62644},"2011-Q4":{"hours":44732,"employees":63,"production":68806},"2011-Q3":{"hours":34579,"employees":65,"production":31233},"2011-Q2":{"hours":8116,"employees":49,"production":14776},"2011-Q1":{"hours":0,"employees":0,"production":0},"2010-Q4":{"hours":0,"employees":0,"production":0},"2010-Q3":{"hours":0,"employees":0,"production":0},"2010-Q2":{"hours":0,"employees":0,"production":0},"2010-Q1":{"hours":0,"employees":0,"production":0},"2009-Q4":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":5,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2011":{"hours":87427,"employees":59,"production":114815},"2012":{"hours":124409,"employees":74,"production":183043}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":28,"firstDate":"2011-07-13","lastDate":"2012-06-12","metrics":{"recentRows":0,"doseOver100":1,"actDoseTotal":1942,"pelDoseTotal":1607},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"265467","EVENT_NO":"6297160","SURVEY_DATE":"06/12/2012","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"20","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2012-06-12"},{"SOURCE_ROW_NUMBER":"265466","EVENT_NO":"6297160","SURVEY_DATE":"06/12/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"95","PEL_DOSE_90":"77","SURVEY_TYPE":"I","sourceDate":"2012-06-12"},{"SOURCE_ROW_NUMBER":"265465","EVENT_NO":"6297160","SURVEY_DATE":"06/12/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"97","PEL_DOSE_90":"78","SURVEY_TYPE":"I","sourceDate":"2012-06-12"},{"SOURCE_ROW_NUMBER":"265464","EVENT_NO":"6297160","SURVEY_DATE":"06/12/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"84","PEL_DOSE_90":"68","SURVEY_TYPE":"I","sourceDate":"2012-06-12"},{"SOURCE_ROW_NUMBER":"265463","EVENT_NO":"6297160","SURVEY_DATE":"06/12/2012","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"113","PEL_DOSE_90":"95","SURVEY_TYPE":"I","sourceDate":"2012-06-12"},{"SOURCE_ROW_NUMBER":"265462","EVENT_NO":"6297160","SURVEY_DATE":"06/12/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"45","PEL_DOSE_90":"20","SURVEY_TYPE":"I","sourceDate":"2012-06-12"},{"SOURCE_ROW_NUMBER":"265461","EVENT_NO":"6297160","SURVEY_DATE":"06/12/2012","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"58","PEL_DOSE_90":"46","SURVEY_TYPE":"I","sourceDate":"2012-06-12"},{"SOURCE_ROW_NUMBER":"265460","EVENT_NO":"6297160","SURVEY_DATE":"06/12/2012","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"54","PEL_DOSE_90":"38","SURVEY_TYPE":"I","sourceDate":"2012-06-12"},{"SOURCE_ROW_NUMBER":"265459","EVENT_NO":"6297160","SURVEY_DATE":"06/12/2012","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"40","PEL_DOSE_90":"24","SURVEY_TYPE":"I","sourceDate":"2012-06-12"},{"SOURCE_ROW_NUMBER":"265458","EVENT_NO":"6297160","SURVEY_DATE":"06/12/2012","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"44","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2012-06-12"},{"SOURCE_ROW_NUMBER":"265457","EVENT_NO":"6297160","SURVEY_DATE":"06/12/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"26","PEL_DOSE_90":"20","SURVEY_TYPE":"I","sourceDate":"2012-06-12"},{"SOURCE_ROW_NUMBER":"265456","EVENT_NO":"6297160","SURVEY_DATE":"06/12/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"36","PEL_DOSE_90":"34","SURVEY_TYPE":"I","sourceDate":"2012-06-12"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":3,"firstDate":"2012-06-05","lastDate":"2012-07-17","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":4,"validSamples":3,"quartzPctTotal":9.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"17640","CASSETTE_NO":"57966483","SAMPLE_DT":"07/17/2012","QUARTZ_PCT":"04.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-07-17"},{"SOURCE_ROW_NUMBER":"137843","CASSETTE_NO":"57966549","SAMPLE_DT":"06/05/2012","QUARTZ_PCT":"02.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-06-05"},{"SOURCE_ROW_NUMBER":"311","CASSETTE_NO":"57966687","SAMPLE_DT":"06/05/2012","QUARTZ_PCT":"02.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-06-05"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":50,"firstDate":"2010-12-21","lastDate":"2014-05-21","metrics":{"ss":20,"amountDue":14316,"contested":0,"amountPaid":14316,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":14316},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2957372","VIOLATION_NO":"9003288","VIOLATION_ISSUE_DT":"05/21/2014","SIG_SUB":"Y","PART_SECTION":"75.1711","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/16/2014","PROPOSED_PENALTY":"585","AMOUNT_DUE":"585","AMOUNT_PAID":"585","CONTESTED_IND":"N","sourceDate":"2014-05-21"},{"SOURCE_ROW_NUMBER":"2957386","VIOLATION_NO":"8125041","VIOLATION_ISSUE_DT":"08/07/2012","PART_SECTION":"75.1403","CIT_ORD_SAFE":"Safeguard","NO_AFFECTED":"0","TERMINATION_DT":"08/09/2012","CONTESTED_IND":"N","sourceDate":"2012-08-07"},{"SOURCE_ROW_NUMBER":"2957385","VIOLATION_NO":"8125040","VIOLATION_ISSUE_DT":"08/02/2012","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"4","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/02/2012","PROPOSED_PENALTY":"1111","AMOUNT_DUE":"1111","AMOUNT_PAID":"1111","CONTESTED_IND":"N","sourceDate":"2012-08-02"},{"SOURCE_ROW_NUMBER":"2957384","VIOLATION_NO":"8125039","VIOLATION_ISSUE_DT":"08/02/2012","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"10","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/02/2012","PROPOSED_PENALTY":"585","AMOUNT_DUE":"585","AMOUNT_PAID":"585","CONTESTED_IND":"N","sourceDate":"2012-08-02"},{"SOURCE_ROW_NUMBER":"2957383","VIOLATION_NO":"8125038","VIOLATION_ISSUE_DT":"08/01/2012","SIG_SUB":"N","PART_SECTION":"77.1103(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/02/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-08-01"},{"SOURCE_ROW_NUMBER":"2957382","VIOLATION_NO":"8125037","VIOLATION_ISSUE_DT":"07/30/2012","SIG_SUB":"N","PART_SECTION":"75.904","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/30/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-07-30"},{"SOURCE_ROW_NUMBER":"2957381","VIOLATION_NO":"8125035","VIOLATION_ISSUE_DT":"07/23/2012","SIG_SUB":"N","PART_SECTION":"75.1103-4(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/23/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-07-23"},{"SOURCE_ROW_NUMBER":"2957380","VIOLATION_NO":"8125034","VIOLATION_ISSUE_DT":"07/11/2012","SIG_SUB":"N","PART_SECTION":"75.1714-6","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"4","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/11/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-07-11"},{"SOURCE_ROW_NUMBER":"2957379","VIOLATION_NO":"8125033","VIOLATION_ISSUE_DT":"07/11/2012","SIG_SUB":"N","PART_SECTION":"75.701","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/11/2012","PROPOSED_PENALTY":"150","AMOUNT_DUE":"150","AMOUNT_PAID":"150","CONTESTED_IND":"N","sourceDate":"2012-07-11"},{"SOURCE_ROW_NUMBER":"2957371","VIOLATION_NO":"8151233","VIOLATION_ISSUE_DT":"06/11/2012","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/11/2012","PROPOSED_PENALTY":"745","AMOUNT_DUE":"745","AMOUNT_PAID":"745","CONTESTED_IND":"N","sourceDate":"2012-06-11"},{"SOURCE_ROW_NUMBER":"2957370","VIOLATION_NO":"8151227","VIOLATION_ISSUE_DT":"06/04/2012","PART_SECTION":"75.1403","CIT_ORD_SAFE":"Safeguard","NO_AFFECTED":"0","TERMINATION_DT":"06/04/2012","CONTESTED_IND":"N","sourceDate":"2012-06-04"},{"SOURCE_ROW_NUMBER":"2957369","VIOLATION_NO":"8151226","VIOLATION_ISSUE_DT":"05/30/2012","SIG_SUB":"N","PART_SECTION":"75.1100-2(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/30/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-05-30"}]}],"safety":{"href":"/api/v1/mines/4609343/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609343/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Sealing of mines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1711","part":"75","subchapter":"O","subpart":"R","id":"75.1711","citation":"30 CFR 75.1711","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403","heading":"Other safeguards.","id":"75.1403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"[Statutory Provisions]\n\nOther safeguards adequate, in the judgment of an authorized representative of the Secretary, to minimize hazards with respect to transportation of men and materials shall be provided.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","heading":"Flammable liquids; storage.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1103","part":"77","subchapter":"O","subpart":"L","id":"77.1103","citation":"30 CFR 77.1103","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.904","heading":"Identification of circuit breakers.","id":"75.904","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-J/section-75.904","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"J","subpartHeading":"Subpart J—Underground Low- and Medium-Voltage Alternating Current Circuits","text":"[Statutory Provisions]\n\nCircuit breakers shall be marked for identification.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1103-4","heading":"Automatic fire sensor and warning device systems; installation; minimum requirements.","id":"75.1103-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Effective December 31, 2009, automatic fire sensor and warning device systems that use carbon monoxide sensors shall provide identification of fire along all belt conveyors.\n\n(1) Carbon monoxide sensors shall be installed at the following locations:\n\n(i) Not more than 100 feet downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up. If the belt drive, tailpiece, and/or take-up for a single transfer point are installed together in the same air course, and the distance between the units is less than 100 feet, they may be monitored with one sensor downwind of the last component. If the distance between the units exceeds 100 feet, additional sensors are required downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up;\n\n(ii) Not more than 100 feet downwind of each section loading point;\n\n(iii) Along the belt entry so that the spacing between sensors does not exceed 1,000 feet. Where air velocities are less than 50 feet per minute, spacing must not exceed 350 feet; and\n\n(iv) The mine operator shall indicate the locations of all carbon monoxide sensors on the mine maps required by §§ 75.1200 and 75.1505 of this part.\n\n(2) Where used, sensors responding to radiation, smoke, gases, or other indications of fire, shall be spaced at regular intervals to provide protection equivalent to carbon monoxide sensors, and installed within the time specified in paragraph (a)(3) of this section.\n\n(3) When the distance from the tailpiece at loading points to the first outby sensor reaches the spacing requirements in § 75.1103-4(a)(1)(iii), an additional sensor shall be installed and put in operation within 24 production shift hours. When sensors of the kind described in paragraph (a)(2) of this section are used, they shall be installed and put in operation within 24 production shift hours after the equivalent distance which has been established for the sensor from the tailpiece at loading points to the first outby sensor is first reached.\n\n(b) Automatic fire sensor and warning device systems shall be installed so as to minimize the possibility of damage from roof falls and the moving belt and its load. Sensors must be installed near the center in the upper third of the entry, in a manner that does not expose personnel working on the system to unsafe conditions. Sensors must not be located in abnormally high areas or in other locations where air flow patterns do not permit products of combustion to be carried to the sensors.\n\n(c) Infrared, ultraviolet, and other sensors whose effectiveness is impaired by contamination shall be protected from dust, dirt, and moisture.\n\n(d) The voltage of automatic fire sensor and warning device systems shall not exceed 120 volts.\n\n(e) Except when power must be cut off in the mine under the provisions of § 75.313, automatic fire sensor and warning device systems shall be capable of giving warning of fire for a minimum of 4 hours after the source of power to the belt is removed unless the belt haulageway is examined for hot rollers and fire as provided in paragraph (e) (1) or (2) of this section.\n\n(1) When an unplanned removal of power from the belt occurs an examination for hot rollers and fire in the operating belts of a conveyor system shall be completed within 2 hours after the belt has stopped.\n\n(2) When a preplanned removal of power from the belt occurs an examination for hot rollers and fire on the operating belts of a conveyor system may commence not more than 30 minutes before the belts are stopped and shall be completed within 2 hours after the examination is commenced, or the examination shall be commenced when the belts are stopped and completed within 2 hours after the belts are stopped.\n\n[37 FR 16545, Aug. 16, 1972, as amended at 57 FR 20928, May 15, 1992; 73 FR 80614, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1714-6","heading":"Emergency tethers.","id":"75.1714-6","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-6","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"At least one tether, which is a durable rope or equivalent material designed to permit members of a mine crew to link together while evacuating the mine during an emergency, shall be provided and stored with the additional SCSRs on the fixed work location and on the mobile equipment required in §§ 75.1714-4(a)(1) and (b) of this part.\n\n[71 FR 71454, Dec. 8, 2006]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.701","heading":"Grounding metallic frames, casings, and other enclosures of electric equipment.","id":"75.701","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-H/section-75.701","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"H","subpartHeading":"Subpart H—Grounding","text":"[Statutory Provisions]\n\nMetallic frames, casings, and other enclosures of electric equipment that can become “alive” through failure of insulation or by contact with energized parts shall be grounded by methods approved by an authorized representative of the Secretary.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609343","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}