{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4609319","name":"Lower War Eagle","status":"Active","status_date":"2020-06-01","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Wyoming","nearest_town":"Cyclone","operator_id":"0210693","operator_name":"Coal Mac East","controller_id":"0144441","controller_name":"John Mitch Potter","district":"C04","office":"Logan WV Field Office","employees":6,"latitude":37.734444,"longitude":-81.727222},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":29425},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609319","name":"Lower War Eagle"},"operator":{"type":"operator","id":"0210693","name":"Coal Mac East"},"controller":{"type":"controller","id":"0144441","name":"John Mitch Potter"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"0072291","name":"INR-I Holdings LLC"},"object":{"type":"mine","id":"4609319","name":"Lower War Eagle"},"validFrom":"2007-12-07","validTo":"2010-08-01","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609319|0072291|2007-12-07|2010-08-01"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0085645","name":"Cliffs Logan County Coal, LLC"},"object":{"type":"mine","id":"4609319","name":"Lower War Eagle"},"validFrom":"2008-11-18","validTo":"2014-12-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609319|0085645|2008-11-18|2014-12-30"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0072291","name":"INR-I Holdings LLC"},"object":{"type":"operator","id":"0085645","name":"Cliffs Logan County Coal, LLC"},"validFrom":"2008-11-18","validTo":"2010-08-01","current":false,"derived":true,"evidenceMineId":"4609319","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609319|0085645|2008-11-18|0072291|2007-12-07|11191"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"M00106","name":"Cleveland-Cliffs Inc"},"object":{"type":"mine","id":"4609319","name":"Lower War Eagle"},"validFrom":"2010-08-02","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609319|M00106|2010-08-02|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"M00106","name":"Cleveland-Cliffs Inc"},"object":{"type":"operator","id":"0085645","name":"Cliffs Logan County Coal, LLC"},"validFrom":"2010-08-02","validTo":"2014-12-30","current":false,"derived":true,"evidenceMineId":"4609319","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609319|0085645|2008-11-18|M00106|2010-08-02|104267"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0109921","name":"Coronado Coal LLC"},"object":{"type":"mine","id":"4609319","name":"Lower War Eagle"},"validFrom":"2013-08-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609319|0109921|2013-08-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0129274","name":"Greenbrier Minerals, LLC"},"object":{"type":"mine","id":"4609319","name":"Lower War Eagle"},"validFrom":"2014-12-31","validTo":"2026-07-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609319|0129274|2014-12-31|2026-07-31"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0109921","name":"Coronado Coal LLC"},"object":{"type":"operator","id":"0129274","name":"Greenbrier Minerals, LLC"},"validFrom":"2014-12-31","validTo":"2026-07-31","current":false,"derived":true,"evidenceMineId":"4609319","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609319|0129274|2014-12-31|0109921|2013-08-01|20066"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0210693","name":"Coal Mac East"},"object":{"type":"mine","id":"4609319","name":"Lower War Eagle"},"validFrom":"2026-08-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609319|0210693|2026-08-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0144441","name":"John Mitch Potter"},"object":{"type":"mine","id":"4609319","name":"Lower War Eagle"},"validFrom":"2026-08-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609319|0144441|2026-08-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0144441","name":"John Mitch Potter"},"object":{"type":"operator","id":"0210693","name":"Coal Mac East"},"validFrom":"2026-08-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609319","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609319|0210693|2026-08-01|0144441|2026-08-01|29512"}}],"coverage":{"historyRecords":4,"edgeCount":11,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":159,"firstDate":"2011-03-02","lastDate":"2026-02-11","metrics":{"daysLost":9766,"injuries":152,"fatalities":2,"recentRows":36,"restrictedDays":620,"contractorRecords":12},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"184721","DOCUMENT_NO":"220260490003","ACCIDENT_DT":"02/11/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Motorman, Motor person, Swamper, Switchman, Locomotive operator","NO_INJURIES":"1","NARRATIVE":"EE was in the process of moving the flat car to the spur track at 8 Head. While moving the flat car and motor into the spur, the flat car rolled, contacting EE's lower leg between the flat car and the motor.","sourceDate":"2026-02-11"},{"SOURCE_ROW_NUMBER":"77195","DOCUMENT_NO":"220253650012","ACCIDENT_DT":"12/18/2025","DEGREE_INJURY":"FATALITY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by powered moving object","OCCUPATION":"Master mechanic, Foreman, Supervisor","NO_INJURIES":"1","NARRATIVE":"The employee stepped out of manhole and onto the slope and was struck by a slope tractor traveling down the slope.","sourceDate":"2025-12-18"},{"SOURCE_ROW_NUMBER":"12704","DOCUMENT_NO":"220253560001","ACCIDENT_DT":"12/17/2025","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Scoop tram operator, Load/Haul/Dump operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE was attempting to cut a clip out of a jumper to gain better access to pull the splice pin, the knife slipped out of the belt, puncturing the EE on the right leg approximately 4\" above the knee, resulting in one suture to close the puncture wound.","sourceDate":"2025-12-17"},{"SOURCE_ROW_NUMBER":"8377","DOCUMENT_NO":"220252660018","ACCIDENT_DT":"09/10/2025","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A fall occurred on September 10, 2025, in-by survey station No. 11515 in the No.22 pillar block. The fall was approximately 8' thick.","sourceDate":"2025-09-10"},{"SOURCE_ROW_NUMBER":"236384","DOCUMENT_NO":"220252300019","ACCIDENT_DT":"08/10/2025","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A fall occurred on 08/10/2025 approx at 12:10 a.m. in the No. 4 entry near spads 17094 and 17085, 20 to 30 feet. This fall was a continuation of a fall that occurred on July 28, 2025, at approx 12:45 pm in the No.4 entry near spad No. 17107. This area has been under a K-Order since July 28 with multiple modifications.","sourceDate":"2025-08-10"},{"SOURCE_ROW_NUMBER":"81484","DOCUMENT_NO":"220251780021","ACCIDENT_DT":"06/23/2025","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"124","NARRATIVE":"EE pulled the roof bolter up to install the next row of bolts. After setting the T-Bar the EE went to step forward off the platform when they slipped and fell forward. Their left foot rolled back while the rest of their body fell forward.","sourceDate":"2025-06-23"},{"SOURCE_ROW_NUMBER":"270692","DOCUMENT_NO":"220251250006","ACCIDENT_DT":"04/24/2025","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Scoop tram operator, Load/Haul/Dump operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE was changing the scoop batteries. While the EE was disconnecting the charger cable from the scoop, the EE accidentally pulled the battery lid down on EE's hand, causing a laceration.","sourceDate":"2025-04-24"},{"SOURCE_ROW_NUMBER":"227753","DOCUMENT_NO":"220251110030","ACCIDENT_DT":"04/14/2025","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"74","NARRATIVE":"EE was turning S/C into the right side dump. EE misjudged the turn and hit the corner of a coal rib with the canopy, which resulted in a piece of coal dislodging and coming in contact with the EE, striking the EE on the right ankle, resulting in a fracture.","sourceDate":"2025-04-14"},{"SOURCE_ROW_NUMBER":"176125","DOCUMENT_NO":"220243380021","ACCIDENT_DT":"11/22/2024","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"STRIKING OR BUMPING","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE was walking out-by down the track entry from the No.3 section. EE was walking in a bent position. The EE came in contact with a roof bolt causing a laceration to left ear which required 8 sutures to close.","sourceDate":"2024-11-22"},{"SOURCE_ROW_NUMBER":"81483","DOCUMENT_NO":"220243170013","ACCIDENT_DT":"11/04/2024","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Miner, NEC","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE lost footing and slipped causing the EE to fall forward and striking their mouth causing a laceration that had to be closed with sutures.","sourceDate":"2024-11-04"},{"SOURCE_ROW_NUMBER":"197489","DOCUMENT_NO":"220242900021","ACCIDENT_DT":"09/06/2024","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE was working on knocking a pin in the C/M cutter boom when a fragment of the hammer hit EE in the right forearm. The EE continues to work in EE's regular position. This incident became reportable on 10/11/2024 due to the removal of the fragment and the receiving of sutures to close the wound.","sourceDate":"2024-09-06"},{"SOURCE_ROW_NUMBER":"42702","DOCUMENT_NO":"220242900020","ACCIDENT_DT":"06/24/2024","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE was dismounting a scoop and twisted right knee. This incident became reportable because the EE had surgery on October 4, 2024. The EE continues to work in EE's regular position with no restrictions.","sourceDate":"2024-06-24"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2020-06-01","lastDate":"2020-06-01","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":3494,"firstDate":"2010-09-29","lastDate":"2026-08-24","metrics":{"ss":730,"delinquent":3397,"recentRows":1289,"paidPenalty":1820797,"proposedPenalty":2425539.9,"currentAssessment":1887831},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2918124","VIOLATION_NO":"5097335","ISSUE_DT":"08/24/2026","CFR_STANDARD_CD":"90.102(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-24"},{"SOURCE_ROW_NUMBER":"2999407","VIOLATION_NO":"5098004","ISSUE_DT":"08/19/2026","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-19"},{"SOURCE_ROW_NUMBER":"2889158","VIOLATION_NO":"5132071","ISSUE_DT":"08/05/2026","CFR_STANDARD_CD":"75.516","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-05"},{"SOURCE_ROW_NUMBER":"2889157","VIOLATION_NO":"5132070","ISSUE_DT":"08/05/2026","CFR_STANDARD_CD":"75.1403","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"336.00","CURRENT_ASSESSMENT_AMT":"336.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-05"},{"SOURCE_ROW_NUMBER":"2999406","VIOLATION_NO":"5097989","ISSUE_DT":"07/20/2026","CFR_STANDARD_CD":"75.364(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-07-20"},{"SOURCE_ROW_NUMBER":"2999405","VIOLATION_NO":"5097988","ISSUE_DT":"07/20/2026","CFR_STANDARD_CD":"75.362(g)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-07-20"},{"SOURCE_ROW_NUMBER":"2999404","VIOLATION_NO":"5097980","ISSUE_DT":"06/18/2026","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-06-18"},{"SOURCE_ROW_NUMBER":"2940360","VIOLATION_NO":"5132040","ISSUE_DT":"06/11/2026","CFR_STANDARD_CD":"48.29(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"2940359","VIOLATION_NO":"5132039","ISSUE_DT":"06/11/2026","CFR_STANDARD_CD":"62.171(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"2940358","VIOLATION_NO":"5132038","ISSUE_DT":"06/09/2026","CFR_STANDARD_CD":"75.1403","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1037.00","CURRENT_ASSESSMENT_AMT":"1037.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-06-09"},{"SOURCE_ROW_NUMBER":"2940357","VIOLATION_NO":"5132037","ISSUE_DT":"06/09/2026","CFR_STANDARD_CD":"75.1403","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1037.00","CURRENT_ASSESSMENT_AMT":"1037.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-06-09"},{"SOURCE_ROW_NUMBER":"2940356","VIOLATION_NO":"5132036","ISSUE_DT":"06/03/2026","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"697.00","CURRENT_ASSESSMENT_AMT":"697.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-06-03"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":909,"firstDate":"2013-07-12","lastDate":"2026-09-18","metrics":{"appeals":0,"decisions":881,"recentRows":496,"decisionPenalty":939125,"originalPenalty":1477242.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"463616","VIOLATION_NO":"5131745","DOCKET_NO":"WEVA 2026-0207","DECISION_DT":"09/18/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"432.00","DECISION_PENALTY_AMT":"432.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-09-18"},{"SOURCE_ROW_NUMBER":"463615","VIOLATION_NO":"5131741","DOCKET_NO":"WEVA 2026-0207","DECISION_DT":"09/18/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"151.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-09-18"},{"SOURCE_ROW_NUMBER":"463614","VIOLATION_NO":"5093495","DOCKET_NO":"WEVA 2026-0207","DECISION_DT":"09/18/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"245.00","DECISION_PENALTY_AMT":"245.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-09-18"},{"SOURCE_ROW_NUMBER":"463613","VIOLATION_NO":"5093469","DOCKET_NO":"WEVA 2026-0207","DECISION_DT":"09/18/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"151.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-09-18"},{"SOURCE_ROW_NUMBER":"463102","VIOLATION_NO":"5131743","DOCKET_NO":"WEVA 2026-0207","DECISION_DT":"09/18/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"504.00","DECISION_PENALTY_AMT":"504.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-09-18"},{"SOURCE_ROW_NUMBER":"463101","VIOLATION_NO":"5131742","DOCKET_NO":"WEVA 2026-0207","DECISION_DT":"09/18/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"226.00","DECISION_PENALTY_AMT":"226.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-09-18"},{"SOURCE_ROW_NUMBER":"463100","VIOLATION_NO":"5131737","DOCKET_NO":"WEVA 2026-0207","DECISION_DT":"09/18/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"7084.00","DECISION_PENALTY_AMT":"2084.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-09-18"},{"SOURCE_ROW_NUMBER":"463099","VIOLATION_NO":"5093488","DOCKET_NO":"WEVA 2026-0207","DECISION_DT":"09/18/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2133.00","DECISION_PENALTY_AMT":"1133.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-09-18"},{"SOURCE_ROW_NUMBER":"463098","VIOLATION_NO":"5093464","DOCKET_NO":"WEVA 2026-0207","DECISION_DT":"09/18/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"642.00","DECISION_PENALTY_AMT":"642.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-09-18"},{"SOURCE_ROW_NUMBER":"462471","VIOLATION_NO":"5186099","DOCKET_NO":"WEVA 2026-0207","DECISION_DT":"09/18/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1818.00","DECISION_PENALTY_AMT":"1818.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-09-18"},{"SOURCE_ROW_NUMBER":"462470","VIOLATION_NO":"5131740","DOCKET_NO":"WEVA 2026-0207","DECISION_DT":"09/18/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"336.00","DECISION_PENALTY_AMT":"336.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-09-18"},{"SOURCE_ROW_NUMBER":"462469","VIOLATION_NO":"5131735","DOCKET_NO":"WEVA 2026-0207","DECISION_DT":"09/18/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2133.00","DECISION_PENALTY_AMT":"1133.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-09-18"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":15265,"firstDate":"2012-03-13","lastDate":"2026-09-23","metrics":{"recentRows":7524,"cpdmSamples":12284,"voidSamples":2563,"validSamples":12702,"maxConcentration":76167.023,"concentrationTotal":104107.035},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1251925","CASS_NUM":"58596009","SMP_TAKEN_DT":"9/23/2026","CONC":".022","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"DISPATCHER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-09-23"},{"SOURCE_ROW_NUMBER":"2774595","SMP_TAKEN_DT":"9/3/2026","CONC":".007","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"DISPATCHER","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-09-03"},{"SOURCE_ROW_NUMBER":"3029835","SMP_TAKEN_DT":"9/2/2026","CONC":"0","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"DISPATCHER","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-09-02"},{"SOURCE_ROW_NUMBER":"2347901","SMP_TAKEN_DT":"9/1/2026","CONC":"0","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"DISPATCHER","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"1751696","SMP_TAKEN_DT":"8/31/2026","CONC":"0","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"DISPATCHER","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-08-31"},{"SOURCE_ROW_NUMBER":"2006926","SMP_TAKEN_DT":"8/28/2026","CONC":"0","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"DISPATCHER","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-08-28"},{"SOURCE_ROW_NUMBER":"2689228","SMP_TAKEN_DT":"8/27/2026","CONC":"0","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"DISPATCHER","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-08-27"},{"SOURCE_ROW_NUMBER":"3026134","SMP_TAKEN_DT":"3/12/2026","CONC":".398","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-03-12"},{"SOURCE_ROW_NUMBER":"2856109","SMP_TAKEN_DT":"3/12/2026","CONC":".278","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-03-12"},{"SOURCE_ROW_NUMBER":"2685497","SMP_TAKEN_DT":"3/12/2026","CONC":".464","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-03-12"},{"SOURCE_ROW_NUMBER":"2088406","SMP_TAKEN_DT":"3/12/2026","CONC":".355","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-03-12"},{"SOURCE_ROW_NUMBER":"913204","CASS_NUM":"58594462","SMP_TAKEN_DT":"3/12/2026","CONC":".09","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-03-12"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":76,"firstDate":"2012-05-11","lastDate":"2026-09-08","metrics":{"linkedIssuances":76},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":909,"firstDate":"2011-12-02","lastDate":"2026-06-03","metrics":{"decisions":881,"ssChanged":95,"recentRows":511,"decisionPenalty":939125,"proposedPenalty":1493594},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"54536","CITATION_NO":"5132036","CITATION_ISSUE_DT":"06/03/2026","DOCKET_NO":"WEVA 2026-0364","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"697.00","sourceDate":"2026-06-03"},{"SOURCE_ROW_NUMBER":"336421","CITATION_NO":"5132035","CITATION_ISSUE_DT":"05/27/2026","DOCKET_NO":"WEVA 2026-0364","CFR_STANDARD_CODE":"75.1403","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1550.00","sourceDate":"2026-05-27"},{"SOURCE_ROW_NUMBER":"167398","CITATION_NO":"5132034","CITATION_ISSUE_DT":"05/27/2026","DOCKET_NO":"WEVA 2026-0364","CFR_STANDARD_CODE":"75.333(e)(1)(ii)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"165.00","sourceDate":"2026-05-27"},{"SOURCE_ROW_NUMBER":"223627","CITATION_NO":"5132033","CITATION_ISSUE_DT":"05/26/2026","DOCKET_NO":"WEVA 2026-0364","CFR_STANDARD_CODE":"75.1107-1(a)(3)(ii)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"165.00","sourceDate":"2026-05-26"},{"SOURCE_ROW_NUMBER":"280127","CITATION_NO":"5132031","CITATION_ISSUE_DT":"05/20/2026","DOCKET_NO":"WEVA 2026-0364","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"151.00","sourceDate":"2026-05-20"},{"SOURCE_ROW_NUMBER":"280389","CITATION_NO":"5132028","CITATION_ISSUE_DT":"05/14/2026","DOCKET_NO":"WEVA 2026-0364","CFR_STANDARD_CODE":"75.516","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"165.00","sourceDate":"2026-05-14"},{"SOURCE_ROW_NUMBER":"54463","CITATION_NO":"5132027","CITATION_ISSUE_DT":"05/14/2026","DOCKET_NO":"WEVA 2026-0364","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"209.00","sourceDate":"2026-05-14"},{"SOURCE_ROW_NUMBER":"336743","CITATION_NO":"5097967","CITATION_ISSUE_DT":"05/13/2026","DOCKET_NO":"WEVA 2026-0364","CFR_STANDARD_CODE":"75.1725(a)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"151.00","sourceDate":"2026-05-13"},{"SOURCE_ROW_NUMBER":"223651","CITATION_NO":"5097966","CITATION_ISSUE_DT":"05/13/2026","DOCKET_NO":"WEVA 2026-0364","CFR_STANDARD_CODE":"75.360(g)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"151.00","sourceDate":"2026-05-13"},{"SOURCE_ROW_NUMBER":"53973","CITATION_NO":"5095507","CITATION_ISSUE_DT":"03/19/2026","DOCKET_NO":"WEVA 2026-0308","DECISION_DT":"08/21/2026","CFR_STANDARD_CODE":"75.1714-2(c)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"4047.00","DECISION_PENALTY_AMT":"818.00","sourceDate":"2026-03-19"},{"SOURCE_ROW_NUMBER":"223423","CITATION_NO":"5132014","CITATION_ISSUE_DT":"03/12/2026","DOCKET_NO":"WEVA 2026-0280","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"209.00","sourceDate":"2026-03-12"},{"SOURCE_ROW_NUMBER":"224752","CITATION_NO":"5132013","CITATION_ISSUE_DT":"03/11/2026","DOCKET_NO":"WEVA 2026-0280","CFR_STANDARD_CODE":"75.1714-4(e)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"697.00","sourceDate":"2026-03-11"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":2221,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":9,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":521,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":9,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":4,"firstDate":"2008-11-18","lastDate":"2026-08-01","metrics":{"recentRows":1,"currentOperatorTenures":1,"completedOperatorTenures":3},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":773,"firstDate":"2010-07-27","lastDate":"2026-10-05","metrics":{"inspectors":1385,"recentRows":309,"onSiteHours":23611,"inspectionHours":34902.25,"inspectionSamples":3239},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1018660","EVENT_NO":"F021D6D","INSPECTION_BEGIN_DT":"10/05/2026","INSPECTION_END_DT":"10/05/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"3.75","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"331618","EVENT_NO":"F021D6C","INSPECTION_BEGIN_DT":"10/01/2026","INSPECTION_END_DT":"10/01/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"7.25","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"708676","EVENT_NO":"F005E92","INSPECTION_BEGIN_DT":"09/23/2026","INSPECTION_END_DT":"09/23/2026","ACTIVITY_CODE":"E22","ACTIVITY":"Health Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12.5","SUM_TOTAL_ON_SITE_HOURS":"9.25","sourceDate":"2026-09-23"},{"SOURCE_ROW_NUMBER":"1116741","EVENT_NO":"F005EB3","INSPECTION_BEGIN_DT":"09/21/2026","INSPECTION_END_DT":"09/21/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2026-09-21"},{"SOURCE_ROW_NUMBER":"790101","EVENT_NO":"F0219DA","INSPECTION_BEGIN_DT":"09/10/2026","INSPECTION_END_DT":"09/10/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2026-09-10"},{"SOURCE_ROW_NUMBER":"285634","EVENT_NO":"7047956","INSPECTION_BEGIN_DT":"09/04/2026","INSPECTION_END_DT":"09/04/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"4.25","sourceDate":"2026-09-04"},{"SOURCE_ROW_NUMBER":"413113","EVENT_NO":"7047955","INSPECTION_BEGIN_DT":"08/24/2026","INSPECTION_END_DT":"08/24/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"6.25","sourceDate":"2026-08-24"},{"SOURCE_ROW_NUMBER":"452000","EVENT_NO":"F0219D8","INSPECTION_BEGIN_DT":"08/19/2026","INSPECTION_END_DT":"08/19/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.25","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2026-08-19"},{"SOURCE_ROW_NUMBER":"170297","EVENT_NO":"7047952","INSPECTION_BEGIN_DT":"08/05/2026","INSPECTION_END_DT":"08/05/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"8.75","sourceDate":"2026-08-05"},{"SOURCE_ROW_NUMBER":"1067587","EVENT_NO":"F0219D6","INSPECTION_BEGIN_DT":"07/28/2026","INSPECTION_END_DT":"07/28/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2026-07-28"},{"SOURCE_ROW_NUMBER":"698214","EVENT_NO":"F0219D4","INSPECTION_BEGIN_DT":"07/20/2026","INSPECTION_END_DT":"07/20/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.5","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2026-07-20"},{"SOURCE_ROW_NUMBER":"764592","EVENT_NO":"F005E8A","INSPECTION_BEGIN_DT":"07/07/2026","INSPECTION_END_DT":"07/07/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2026-07-07"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":212,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2026-Q2":{"hours":5755,"employees":9,"production":2502},"2026-Q1":{"hours":80466,"employees":129,"production":67567},"2025-Q4":{"hours":96828,"employees":161,"production":101014},"2025-Q3":{"hours":110307,"employees":165,"production":98954},"2025-Q2":{"hours":108746,"employees":164,"production":118316},"2025-Q1":{"hours":109642,"employees":169,"production":143670},"2024-Q4":{"hours":102065,"employees":169,"production":122896},"2024-Q3":{"hours":104599,"employees":169,"production":113572},"2024-Q2":{"hours":109737,"employees":163,"production":128777},"2024-Q1":{"hours":108836,"employees":168,"production":132180},"2023-Q4":{"hours":95802,"employees":161,"production":115666},"2023-Q3":{"hours":98213,"employees":143,"production":115480}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":49,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017":{"hours":494894,"employees":204,"production":816363},"2018":{"hours":474904,"employees":178,"production":825143},"2019":{"hours":462116,"employees":186,"production":695862},"2020":{"hours":316212,"employees":139,"production":503660},"2021":{"hours":354297,"employees":139,"production":530510},"2022":{"hours":340801,"employees":129,"production":504903},"2023":{"hours":377712,"employees":145,"production":508933},"2024":{"hours":425237,"employees":167,"production":497425},"2025":{"hours":425523,"employees":165,"production":461954},"2026":{"hours":86221,"employees":72,"production":70069}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":548,"firstDate":"2012-09-25","lastDate":"2026-02-18","metrics":{"recentRows":170,"doseOver100":74,"actDoseTotal":37510,"pelDoseTotal":27042},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"265202","EVENT_NO":"F00D98D","SURVEY_DATE":"02/18/2026","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"40","ACT_DOSE_85":"37","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2026-02-18"},{"SOURCE_ROW_NUMBER":"265201","EVENT_NO":"F00D98D","SURVEY_DATE":"02/18/2026","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"35","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2026-02-18"},{"SOURCE_ROW_NUMBER":"265200","EVENT_NO":"F00D98D","SURVEY_DATE":"02/18/2026","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"53","PEL_DOSE_90":"39","SURVEY_TYPE":"I","sourceDate":"2026-02-18"},{"SOURCE_ROW_NUMBER":"265199","EVENT_NO":"F00D98D","SURVEY_DATE":"02/18/2026","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","ACT_DOSE_85":"45","PEL_DOSE_90":"33","SURVEY_TYPE":"I","sourceDate":"2026-02-18"},{"SOURCE_ROW_NUMBER":"265198","EVENT_NO":"F00D98D","SURVEY_DATE":"02/18/2026","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"86","PEL_DOSE_90":"72","SURVEY_TYPE":"I","sourceDate":"2026-02-18"},{"SOURCE_ROW_NUMBER":"265197","EVENT_NO":"F00D98D","SURVEY_DATE":"01/28/2026","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","ACT_DOSE_85":"19","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2026-01-28"},{"SOURCE_ROW_NUMBER":"265196","EVENT_NO":"F00D981","SURVEY_DATE":"12/09/2025","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","ACT_DOSE_85":"47","PEL_DOSE_90":"28","SURVEY_TYPE":"I","sourceDate":"2025-12-09"},{"SOURCE_ROW_NUMBER":"265195","EVENT_NO":"F00D981","SURVEY_DATE":"12/09/2025","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"41","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2025-12-09"},{"SOURCE_ROW_NUMBER":"265194","EVENT_NO":"F00D981","SURVEY_DATE":"12/09/2025","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"60","PEL_DOSE_90":"40","SURVEY_TYPE":"I","sourceDate":"2025-12-09"},{"SOURCE_ROW_NUMBER":"265193","EVENT_NO":"F00D981","SURVEY_DATE":"12/09/2025","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"95","PEL_DOSE_90":"83","SURVEY_TYPE":"I","sourceDate":"2025-12-09"},{"SOURCE_ROW_NUMBER":"265192","EVENT_NO":"F00D981","SURVEY_DATE":"12/09/2025","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"71","PEL_DOSE_90":"50","SURVEY_TYPE":"I","sourceDate":"2025-12-09"},{"SOURCE_ROW_NUMBER":"265191","EVENT_NO":"F00D981","SURVEY_DATE":"10/29/2025","OCCUPATION_CD_DESC":"DISPATCHER","MACHINE_CD":"40","ACT_DOSE_85":"24","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2025-10-29"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":719,"firstDate":"2012-12-11","lastDate":"2026-02-18","metrics":{"recentRows":335,"voidSamples":42,"maxQuartzPct":13.6,"validSamples":677,"quartzPctTotal":3154.8},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"161854","CASSETTE_NO":"58594531","SAMPLE_DT":"02/18/2026","QUARTZ_PCT":"04.3","QUARTZ_MICROGRAMS":"18","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-02-18"},{"SOURCE_ROW_NUMBER":"129780","CASSETTE_NO":"58594543","SAMPLE_DT":"02/18/2026","QUARTZ_PCT":"04.8","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-02-18"},{"SOURCE_ROW_NUMBER":"122025","CASSETTE_NO":"58594530","SAMPLE_DT":"02/18/2026","QUARTZ_PCT":"03.5","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-02-18"},{"SOURCE_ROW_NUMBER":"29863","CASSETTE_NO":"58594566","SAMPLE_DT":"02/18/2026","QUARTZ_PCT":"02.5","QUARTZ_MICROGRAMS":"13","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-02-18"},{"SOURCE_ROW_NUMBER":"28135","CASSETTE_NO":"58594663","SAMPLE_DT":"02/18/2026","QUARTZ_PCT":"01.9","QUARTZ_MICROGRAMS":"16","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-02-18"},{"SOURCE_ROW_NUMBER":"11791","CASSETTE_NO":"58594437","SAMPLE_DT":"02/18/2026","QUARTZ_PCT":"03.0","QUARTZ_MICROGRAMS":"20","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-02-18"},{"SOURCE_ROW_NUMBER":"19633","CASSETTE_NO":"58569490","SAMPLE_DT":"01/28/2026","QUARTZ_PCT":"02.9","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"LABORER","SAMPLE_TYPE_DESC":"PART 90 MINER","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-01-28"},{"SOURCE_ROW_NUMBER":"157665","CASSETTE_NO":"58569505","SAMPLE_DT":"12/09/2025","QUARTZ_PCT":"02.9","QUARTZ_MICROGRAMS":"12","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-12-09"},{"SOURCE_ROW_NUMBER":"149065","CASSETTE_NO":"58569506","SAMPLE_DT":"12/09/2025","QUARTZ_PCT":"01.3","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-12-09"},{"SOURCE_ROW_NUMBER":"134007","CASSETTE_NO":"58569515","SAMPLE_DT":"12/09/2025","QUARTZ_PCT":"03.7","QUARTZ_MICROGRAMS":"11","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-12-09"},{"SOURCE_ROW_NUMBER":"124973","CASSETTE_NO":"58569494","SAMPLE_DT":"12/09/2025","QUARTZ_PCT":"04.5","QUARTZ_MICROGRAMS":"14","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-12-09"},{"SOURCE_ROW_NUMBER":"97592","CASSETTE_NO":"58569525","SAMPLE_DT":"12/09/2025","QUARTZ_PCT":"02.3","QUARTZ_MICROGRAMS":"17","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-12-09"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":3564,"firstDate":"2010-09-29","lastDate":"2026-10-01","metrics":{"ss":723,"amountDue":1887831,"contested":0,"amountPaid":1820797,"recentRows":1311,"section104d":9,"unterminated":6,"proposedPenalty":2425539.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2955616","VIOLATION_NO":"5098016","VIOLATION_ISSUE_DT":"10/01/2026","SIG_SUB":"N","PART_SECTION":"75.364(g)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/05/2026","CONTESTED_IND":"N","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"2955615","VIOLATION_NO":"5098015","VIOLATION_ISSUE_DT":"10/01/2026","SIG_SUB":"N","PART_SECTION":"75.809","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/05/2026","CONTESTED_IND":"N","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"2955614","VIOLATION_NO":"5098014","VIOLATION_ISSUE_DT":"10/01/2026","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/05/2026","CONTESTED_IND":"N","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"2954765","VIOLATION_NO":"5130889","VIOLATION_ISSUE_DT":"09/16/2026","SIG_SUB":"N","PART_SECTION":"75.1202","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/21/2026","CONTESTED_IND":"N","sourceDate":"2026-09-16"},{"SOURCE_ROW_NUMBER":"2954764","VIOLATION_NO":"5130888","VIOLATION_ISSUE_DT":"09/08/2026","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/15/2026","CONTESTED_IND":"N","sourceDate":"2026-09-08"},{"SOURCE_ROW_NUMBER":"2954763","VIOLATION_NO":"5097335","VIOLATION_ISSUE_DT":"08/24/2026","SIG_SUB":"N","PART_SECTION":"90.102(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/25/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-08-24"},{"SOURCE_ROW_NUMBER":"2955210","VIOLATION_NO":"5098004","VIOLATION_ISSUE_DT":"08/19/2026","SIG_SUB":"N","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/24/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-08-19"},{"SOURCE_ROW_NUMBER":"2955188","VIOLATION_NO":"5132071","VIOLATION_ISSUE_DT":"08/05/2026","SIG_SUB":"N","PART_SECTION":"75.516","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/05/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-08-05"},{"SOURCE_ROW_NUMBER":"2955187","VIOLATION_NO":"5132070","VIOLATION_ISSUE_DT":"08/05/2026","SIG_SUB":"Y","PART_SECTION":"75.1403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/05/2026","PROPOSED_PENALTY":"336","AMOUNT_DUE":"336","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-08-05"},{"SOURCE_ROW_NUMBER":"2955143","VIOLATION_NO":"5097989","VIOLATION_ISSUE_DT":"07/20/2026","SIG_SUB":"N","PART_SECTION":"75.364(h)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"07/20/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-07-20"},{"SOURCE_ROW_NUMBER":"2955142","VIOLATION_NO":"5097988","VIOLATION_ISSUE_DT":"07/20/2026","SIG_SUB":"N","PART_SECTION":"75.362(g)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/20/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-07-20"},{"SOURCE_ROW_NUMBER":"2954374","VIOLATION_NO":"5097980","VIOLATION_ISSUE_DT":"06/18/2026","SIG_SUB":"N","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/22/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-06-18"}]}],"safety":{"href":"/api/v1/mines/4609319/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609319/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":{"averageEmployees":168,"companyType":"Operating Subsidiary","components":[{"averageEmployees":168,"laborHours":425237,"mineType":"Underground","productionTons":497425}],"county":"Wyoming","laborHours":425237,"mineName":"Lower War Eagle","mineType":"Underground","mshaId":"4609319","operatingAddress":"P.O. Box 446, Man, WV 25635","operatingCompany":"Greenbrier Minerals, Llc","operationType":"Mine only","productionTons":497425,"reportedRows":1,"sourceUrl":"https://www.eia.gov/coal/data/public/xls/coalpublic2024.xlsx","state":"West Virginia (Southern)","status":"Active","supplyRegion":"Appalachia Central","union":"","year":2024},"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.364","heading":"Weekly examination.","id":"75.364","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.364","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Worked-out areas. (1) At least every 7 days, a certified person shall examine unsealed worked-out areas where no pillars have been recovered by traveling to the area of deepest penetration; measuring methane and oxygen concentrations and air quantities and making tests to determine if the air is moving in the proper direction in the area. The locations of measurement points where tests and measurements will be performed shall be included in the mine ventilation plan and shall be adequate in number and location to assure ventilation and air quality in the area. Air quantity measurements shall also be made where the air enters and leaves the worked-out area. An alternative method of evaluating the ventilation of the area may be approved in the ventilation plan.\n\n(2) At least every 7 days, a certified person shall evaluate the effectiveness of bleeder systems required by § 75.334 as follows:\n\n(i) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in its proper direction shall be made where air enters the worked-out area.\n\n(ii) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in the proper direction shall be made immediately before the air enters a return split of air.\n\n(iii) At least one entry of each set of bleeder entries used as part of a bleeder system under § 75.334 shall be traveled in its entirety. Measurements of methane and oxygen concentrations and air quantities and a test to determine if the air is moving in the proper direction shall be made at the measurement point locations specified in the mine ventilation plan to determine the effectiveness of the bleeder system.\n\n(iv) In lieu of the requirements of paragraphs (a)(2)(i) and (iii) of this section, an alternative method of evaluation may be specified in the ventilation plan provided the alternative method results in proper evaluation of the effectiveness of the bleeder system.\n\n(b) Hazardous conditions and violations of mandatory health or safety standards. At least every 7 days, an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(8) of this section shall be made by a certified person designated by the operator at the following locations:\n\n(1) In at least one entry of each intake air course, in its entirety, so that the entire air course is traveled.\n\n(2) In at least one entry of each return air course, in its entirety, so that the entire air course is traveled.\n\n(3) In each longwall or shortwall travelway in its entirety, so that the entire travelway is traveled.\n\n(4) At each seal along return and bleeder air courses and at each seal along intake air courses not examined under § 75.360(b)(5).\n\n(5) In each escapeway so that the entire escapeway is traveled.\n\n(6) On each working section not examined under § 75.360(b)(3) during the previous 7 days.\n\n(7) At each water pump not examined during a preshift examination conducted during the previous 7 days.\n\n(8) Weekly examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust; and\n\n(iv) § 75.1403—maintenance of off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) Measurements and tests. At least every 7 days, a certified person shall—\n\n(1) Determine the volume of air entering the main intakes and in each intake split;\n\n(2) Determine the volume of air and test for methane in the last open crosscut in any pair or set of developing entries or rooms, in the return of each split of air immediately before it enters the main returns, and where the air leaves the main returns; and\n\n(3) Test for methane in the return entry nearest each set of seals immediately after the air passes the seals.\n\n(d) Hazardous conditions shall be corrected immediately. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Any violation of the nine mandatory health or safety standards found during a weekly examination shall be corrected.\n\n(e) The weekly examination may be conducted at the same time as the preshift or on-shift examinations.\n\n(f) (1) The weekly examination is not required during any 7 day period in which no one enters any underground area of the mine.\n\n(2) Except for certified persons required to make examinations, no one shall enter any underground area of the mine if a weekly examination has not been completed within the previous 7 days.\n\n(g) Certification. The person making the weekly examinations shall certify by initials, date, and the time that the examination was made. Certifications and times shall appear at enough locations to show that the entire area has been examined.\n\n(h) Recordkeeping. At the completion of any shift during which a portion of a weekly examination is conducted, a record of the results of each weekly examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards found during each examination and their locations, the corrective action taken, and the results and location of air and methane measurements, shall be made. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the person making the examination or a person designated by the operator. If made by a person other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(i) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 77 FR 20715, Apr. 6, 2012]","occurrenceCount":2},{"chapter":"I","heading":"Identification of circuit breakers and disconnecting switches.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-I/section-75.809","part":"75","subchapter":"O","subpart":"I","id":"75.809","citation":"30 CFR 75.809","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1202","heading":"Temporary notations, revisions, and supplements.","id":"75.1202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-M/section-75.1202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"M","subpartHeading":"Subpart M—Maps","text":"[Statutory Provisions]\n\nSuch map shall be kept up-to-date by temporary notations and such map shall be revised and supplemented at intervals prescribed by the Secretary on the basis of a survey made or certified by such engineer or surveyor.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","heading":"Transfer; notice.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-90/subpart-B/section-90.102","part":"90","subchapter":"O","subpart":"B","id":"90.102","citation":"30 CFR 90.102","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 90—MANDATORY HEALTH STANDARDS—COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.516","heading":"Power wires; support.","id":"75.516","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.516","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll power wires (except trailing cables on mobile equipment, specially designed cables conducting high-voltage power to underground rectifying equipment or transformers, or bare or insulated ground and return wires) shall be supported on well-insulated insulators and shall not contact combustible material, roof, or ribs.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403","heading":"Other safeguards.","id":"75.1403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"[Statutory Provisions]\n\nOther safeguards adequate, in the judgment of an authorized representative of the Secretary, to minimize hazards with respect to transportation of men and materials shall be provided.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.362","heading":"On-shift examination.","id":"75.362","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.362","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) At least once during each shift, or more often if necessary for safety, a certified person designated by the operator shall conduct an on-shift examination of each section where anyone is assigned to work during the shift and any area where mechanized mining equipment is being installed or removed during the shift. The certified person shall check for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (a)(3) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction.\n\n(2) A person designated by the operator shall conduct an examination and record the results and the corrective actions taken to assure compliance with the respirable dust control parameters specified in the approved mine ventilation plan. In those instances when a shift change is accomplished without an interruption in production on a section, the examination shall be made anytime within 1 hour after the shift change. In those instances when there is an interruption in production during the shift change, the examination shall be made before production begins on a section. Deficiencies in dust controls shall be corrected before production begins or resumes. The examination shall include: Air quantities and velocities; water pressures and flow rates; excessive leakage in the water delivery system; water spray numbers and orientations; section ventilation and control device placement; roof bolting machine dust collector vacuum levels; scrubber air flow rate; work practices required by the ventilation plan; and any other dust suppression measures. Measurements of the air velocity and quantity, water pressure and flow rates are not required if continuous monitoring of these controls is used and indicates that the dust controls are functioning properly.\n\n(3) On-shift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(b) During each shift that coal is produced, a certified person shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (a)(3) of this section along each belt conveyor haulageway where a belt conveyor is operated. This examination may be conducted at the same time as the preshift examination of belt conveyors and belt conveyor haulageways, if the examination is conducted within 3 hours before the oncoming shift.\n\n(c) Persons conducting the on-shift examination shall determine at the following locations:\n\n(1) The volume of air in the last open crosscut of each set of entries or rooms on each section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) The volume of air on a longwall or shortwall, including areas where longwall or shortwall equipment is being installed or removed, in the intake entry or entries at the intake end of the longwall or shortwall.\n\n(3) The velocity of air at each end of the longwall or shortwall face at the locations specified in the approved ventilation plan.\n\n(4) The volume of air at the intake end of any pillar line—\n\n(i) Where a single split of air is used in the intake entry furthest from the return air course immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) Where a split system is used in the intake entries of each split immediately inby the split point.\n\n(d) (1) A qualified person shall make tests for methane—\n\n(i) At the start of each shift at each working place before electrically operated equipment is energized; and\n\n(ii) Immediately before equipment is energized, taken into, or operated in a working place; and\n\n(iii) At 20-minute intervals, or more often if required in the approved ventilation plan at specific locations, during the operation of equipment in the working place.\n\n(2) Except as provided for in paragraph (d)(3) of this section, these methane tests shall be made at the face from under permanent roof support, using extendable probes or other acceptable means. When longwall or shortwall mining systems are used, these methane tests shall be made at the shearer, the plow, or the cutting head. When mining has been stopped for more than 20 minutes, methane tests shall be conducted prior to the start up of equipment.\n\n(3) As an alternative method of compliance with paragraph (d)(2) of this section during roof bolting, methane tests may be made by sweeping an area not less than 16 feet inby the last area of permanently supported roof, using a probe or other acceptable means. This method of testing is conditioned on meeting the following requirements:\n\n(i) The roof bolting machine must be equipped with an integral automated temporary roof support (ATRS) system that meets the requirements of 30 CFR 75.209.\n\n(ii) The roof bolting machine must have a permanently mounted, MSHA-approved methane monitor which meets the maintenance and calibration requirements of 30 CFR 75.342(a)(4), the warning signal requirements of 30 CFR 75.342(b), and the automatic de-energization requirements of 30 CFR 75.342(c).\n\n(iii) The methane monitor sensor must be mounted near the inby end and within 18 inches of the longitudinal center of the ATRS support, and positioned at least 12 inches from the roof when the ATRS is fully deployed.\n\n(iv) Manual methane tests must be made at intervals not exceeding 20 minutes. The test may be made either from under permanent roof support or from the roof bolter's work position protected by the deployed ATRS.\n\n(v) Once a methane test is made at the face, all subsequent methane tests in the same area of unsupported roof must also be made at the face, from under permanent roof support, using extendable probes or other acceptable means at intervals not exceeding 20 minutes.\n\n(vi) The district manager may require that the ventilation plan include the minimum air quantity and the position and placement of ventilation controls to be maintained during roof bolting.\n\n(e) If auxiliary fans and tubing are used, they shall be inspected frequently.\n\n(f) During each shift that coal is produced and at intervals not exceeding 4 hours, tests for methane shall be made by a certified person or by an atmospheric monitoring system (AMS) in each return split of air from each working section between the last working place, or longwall or shortwall face, ventilated by that split of air and the junction of the return air split with another air split, seal, or worked-out area. If auxiliary fans and tubing are used, the tests shall be made at a location outby the auxiliary fan discharge.\n\n(g) Certification. (1) The person conducting the on-shift examination in belt haulage entries shall certify by initials, date, and time that the examination was made. The certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(2) The certified person directing the on-shift examination to assure compliance with the respirable dust control parameters specified in the approved mine ventilation plan shall:\n\n(i) Certify by initials, date, and time on a board maintained at the section load-out or similar location showing that the examination was made prior to resuming production; and\n\n(ii) Verify, by initials and date, the record of the results of the examination required under (a)(2) of this section to assure compliance with the respirable dust control parameters specified in the mine ventilation plan. The verification shall be made no later than the end of the shift for which the examination was made.\n\n(3) The mine foreman or equivalent mine official shall countersign each examination record required under (a)(2) of this section after it is verified by the certified person under (g)(2)(ii) of this section, and no later than the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The record shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(4) Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 26442, May 28, 1996, as amended at 68 FR 40138, July 7, 2003; 77 FR 20715, Apr. 6, 2012; 79 FR 24987, May 1, 2014]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609319","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}