{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4609311","name":"Mine No. 1","status":"NonProducing","status_date":"2026-08-07","mine_type":"Surface","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Mercer","nearest_town":"Montcalm","operator_id":"0098205","operator_name":"Onyx Energy, LLC","controller_id":"0141301","controller_name":"Mohegan Energy Trustees LLC","district":"C04","office":"Beckley Field Office","employees":21,"latitude":37.388611,"longitude":-81.268889},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":2103},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609311","name":"Mine No. 1"},"operator":{"type":"operator","id":"0098205","name":"Onyx Energy, LLC"},"controller":{"type":"controller","id":"0141301","name":"Mohegan Energy Trustees LLC"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"0098205","name":"Onyx Energy, LLC"},"object":{"type":"mine","id":"4609311","name":"Mine No. 1"},"validFrom":"2008-12-04","validTo":"2025-07-26","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609311|0098205|2008-12-04|2025-07-26"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C01825","name":"Richard G  Preservati II"},"object":{"type":"mine","id":"4609311","name":"Mine No. 1"},"validFrom":"2008-12-04","validTo":"2018-05-15","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609311|C01825|2008-12-04|2018-05-15"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C01825","name":"Richard G  Preservati II"},"object":{"type":"operator","id":"0098205","name":"Onyx Energy, LLC"},"validFrom":"2008-12-04","validTo":"2018-05-15","current":false,"derived":true,"evidenceMineId":"4609311","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609311|0098205|2008-12-04|C01825|2008-12-04|56275"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0141301","name":"Mohegan Energy Trustees LLC"},"object":{"type":"mine","id":"4609311","name":"Mine No. 1"},"validFrom":"2018-05-16","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609311|0141301|2018-05-16|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0141301","name":"Mohegan Energy Trustees LLC"},"object":{"type":"operator","id":"0098205","name":"Onyx Energy, LLC"},"validFrom":"2018-05-16","validTo":"2025-07-26","current":false,"derived":true,"evidenceMineId":"4609311","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609311|0098205|2008-12-04|0141301|2018-05-16|28580"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0182400","name":"John  Stone"},"object":{"type":"mine","id":"4609311","name":"Mine No. 1"},"validFrom":"2024-02-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609311|0182400|2024-02-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0193593","name":"Stacy Equipment and Repairs, Incorporated"},"object":{"type":"mine","id":"4609311","name":"Mine No. 1"},"validFrom":"2025-07-27","validTo":"2026-04-01","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609311|0193593|2025-07-27|2026-04-01"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0182400","name":"John  Stone"},"object":{"type":"operator","id":"0193593","name":"Stacy Equipment and Repairs, Incorporated"},"validFrom":"2025-07-27","validTo":"2026-04-01","current":false,"derived":true,"evidenceMineId":"4609311","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609311|0193593|2025-07-27|0182400|2024-02-01|38946"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0098205","name":"Onyx Energy, LLC"},"object":{"type":"mine","id":"4609311","name":"Mine No. 1"},"validFrom":"2026-04-02","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609311|0098205|2026-04-02|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0141301","name":"Mohegan Energy Trustees LLC"},"object":{"type":"operator","id":"0098205","name":"Onyx Energy, LLC"},"validFrom":"2026-04-02","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609311","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609311|0098205|2026-04-02|0141301|2018-05-16|28581"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C01825","name":"Richard G  Preservati II"},"object":{"type":"operator","id":"0098205","name":"Onyx Energy, LLC"},"validFrom":"2026-04-02","validTo":"2018-05-15","current":false,"derived":true,"evidenceMineId":"4609311","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609311|0098205|2026-04-02|C01825|2008-12-04|56276"}}],"coverage":{"historyRecords":5,"edgeCount":11,"intervalAnomalies":1,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":8,"firstDate":"2015-05-28","lastDate":"2023-08-21","metrics":{"daysLost":423,"injuries":8,"fatalities":0,"recentRows":2,"restrictedDays":4,"contractorRecords":4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"141706","DOCUMENT_NO":"220232340033","ACCIDENT_DT":"08/21/2023","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Haul/Off road/Coal/Ore/Pit/Quarry/Rock/Rubber tire truck driver, Transportation truck driver","NO_INJURIES":"1","DAYS_LOST":"8","NARRATIVE":"Employee stated hand slipped on access ladder on rear of water truck and EE's wedding ring got caught and cut EE's finger.","sourceDate":"2023-08-21"},{"SOURCE_ROW_NUMBER":"249260","DOCUMENT_NO":"220210290014","ACCIDENT_DT":"01/18/2021","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Blaster, Shooter, Shotfirer, Explosive worker, Powder gang/monkey","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Stepped on a piece of drill steel that was buried in the snow, twisted right ankle.","sourceDate":"2021-01-18"},{"SOURCE_ROW_NUMBER":"176123","DOCUMENT_NO":"220180570005","ACCIDENT_DT":"02/21/2018","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Drill operator","NO_INJURIES":"1","DAYS_LOST":"72","NARRATIVE":"Employee was lifting on \"Leveling Jack Pad\" when employee felt something pull in shoulder","sourceDate":"2018-02-21"},{"SOURCE_ROW_NUMBER":"12700","DOCUMENT_NO":"220173390002","ACCIDENT_DT":"11/24/2017","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Superintendent","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was using an impact wrench to remove a bolt from belt skirting when the socket broke. A small piece of metal flew back striking employee on cheek and then metal went under the safety glasses and penetrated employee's eyelid.","sourceDate":"2017-11-24"},{"SOURCE_ROW_NUMBER":"219176","DOCUMENT_NO":"220170120001","ACCIDENT_DT":"12/29/2016","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Drill operator","NO_INJURIES":"1","DAYS_LOST":"10","NARRATIVE":"While employee was picking up a deck wrench, they felt a pain in the stomach.","sourceDate":"2016-12-29"},{"SOURCE_ROW_NUMBER":"94195","DOCUMENT_NO":"220162240023","ACCIDENT_DT":"08/05/2016","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"Cutting rope with pocket knife. Cut left forearm.","sourceDate":"2016-08-05"},{"SOURCE_ROW_NUMBER":"51300","DOCUMENT_NO":"220160750002","ACCIDENT_DT":"03/08/2016","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"330","NARRATIVE":"A timber cutter for Virco Inc. was cutting a tree on a mine site located in Mercer County WV. As EE was cutting the tree there was another tree lodged up against the tree that EE was cutting. When the tree fell it pulled the other tree down hitting the timber cutter in the back. (broken arm)(broken shoulder)(broken ribs)(cut on hand).","sourceDate":"2016-03-08"},{"SOURCE_ROW_NUMBER":"274950","DOCUMENT_NO":"220151530013","ACCIDENT_DT":"05/28/2015","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Replacing control valve on D11.  Used swivel socket to take out bottom bolts.  Had socket on impact.  Safety ring came off the socket and the pin came out cutting his left hand through his safety glove.","sourceDate":"2015-05-28"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2026-08-07","lastDate":"2026-08-07","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":170,"firstDate":"2009-01-07","lastDate":"2026-07-15","metrics":{"ss":47,"delinquent":166,"recentRows":83,"paidPenalty":47040,"proposedPenalty":127027,"currentAssessment":66661},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2979789","VIOLATION_NO":"5024562","ISSUE_DT":"07/15/2026","CFR_STANDARD_CD":"77.1007(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"193.00","CURRENT_ASSESSMENT_AMT":"193.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-07-15"},{"SOURCE_ROW_NUMBER":"2979788","VIOLATION_NO":"5024561","ISSUE_DT":"07/15/2026","CFR_STANDARD_CD":"72.620","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"432.00","CURRENT_ASSESSMENT_AMT":"432.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-07-15"},{"SOURCE_ROW_NUMBER":"3014812","VIOLATION_NO":"5090783","ISSUE_DT":"11/18/2025","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2025-11-18"},{"SOURCE_ROW_NUMBER":"3014811","VIOLATION_NO":"5090782","ISSUE_DT":"11/18/2025","CFR_STANDARD_CD":"77.1109(c)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2025-11-18"},{"SOURCE_ROW_NUMBER":"3014810","VIOLATION_NO":"5090781","ISSUE_DT":"11/18/2025","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2025-11-18"},{"SOURCE_ROW_NUMBER":"3014809","VIOLATION_NO":"5090772","ISSUE_DT":"11/03/2025","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2025-11-03"},{"SOURCE_ROW_NUMBER":"3014808","VIOLATION_NO":"5090769","ISSUE_DT":"10/27/2025","CFR_STANDARD_CD":"77.1001","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"226.00","CURRENT_ASSESSMENT_AMT":"226.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2025-10-27"},{"SOURCE_ROW_NUMBER":"3014807","VIOLATION_NO":"5090762","ISSUE_DT":"10/20/2025","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2025-10-20"},{"SOURCE_ROW_NUMBER":"3014806","VIOLATION_NO":"5090761","ISSUE_DT":"10/20/2025","CFR_STANDARD_CD":"77.1103(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2025-10-20"},{"SOURCE_ROW_NUMBER":"3014805","VIOLATION_NO":"5090760","ISSUE_DT":"10/15/2025","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2025-10-15"},{"SOURCE_ROW_NUMBER":"3014804","VIOLATION_NO":"5090759","ISSUE_DT":"10/15/2025","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2025-10-15"},{"SOURCE_ROW_NUMBER":"3014803","VIOLATION_NO":"5090758","ISSUE_DT":"10/08/2025","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2025-10-08"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":4,"firstDate":"2011-03-08","lastDate":"2017-08-30","metrics":{"appeals":0,"decisions":4,"recentRows":0,"decisionPenalty":12216,"originalPenalty":71574},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"391627","VIOLATION_NO":"9064114","DOCKET_NO":"WEVA 2017-0285","DECISION_DT":"08/30/2017","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"116.00","DECISION_PENALTY_AMT":"116.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2017-08-30"},{"SOURCE_ROW_NUMBER":"385232","VIOLATION_NO":"9014260","DOCKET_NO":"WEVA 2016-0523","DECISION_DT":"07/25/2017","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"70000.00","DECISION_PENALTY_AMT":"12000.00","JUDGE_FIRST_NAME":"Jerold","JUDGE_LAST_NAME":"Feldman","sourceDate":"2017-07-25"},{"SOURCE_ROW_NUMBER":"245401","VIOLATION_NO":"6620407","DOCKET_NO":"WEVA 2009-1432","DECISION_DT":"03/08/2011","DECISION_TYPE_CODE_DESC":"Withdrawal","ORIGINAL_PENALTY_AMT":"1337.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2011-03-08"},{"SOURCE_ROW_NUMBER":"244988","VIOLATION_NO":"6620406","DOCKET_NO":"WEVA 2009-1432","DECISION_DT":"03/08/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2011-03-08"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":388,"firstDate":"2009-07-22","lastDate":"2026-07-27","metrics":{"recentRows":124,"cpdmSamples":0,"voidSamples":17,"validSamples":371,"maxConcentration":2.276,"concentrationTotal":87.506},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1269140","CASS_NUM":"58573843","SMP_TAKEN_DT":"7/27/2026","CONC":".052","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHWALL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-07-27"},{"SOURCE_ROW_NUMBER":"1007123","CASS_NUM":"58573941","SMP_TAKEN_DT":"7/27/2026","CONC":".034","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-07-27"},{"SOURCE_ROW_NUMBER":"550078","CASS_NUM":"58573945","SMP_TAKEN_DT":"7/27/2026","CONC":".139","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-07-27"},{"SOURCE_ROW_NUMBER":"379943","CASS_NUM":"58573787","SMP_TAKEN_DT":"7/27/2026","CONC":".076","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-07-27"},{"SOURCE_ROW_NUMBER":"1263068","CASS_NUM":"51681036","SMP_TAKEN_DT":"6/24/2026","CONC":".108","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHWALL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-06-24"},{"SOURCE_ROW_NUMBER":"426370","CASS_NUM":"51681023","SMP_TAKEN_DT":"6/24/2026","CONC":".042","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-06-24"},{"SOURCE_ROW_NUMBER":"290343","CASS_NUM":"51668831","SMP_TAKEN_DT":"12/23/2025","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"DISCARDED SAMPLE (TOO OLD)","OCC_CD_DESC":"HIGHWALL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-12-23"},{"SOURCE_ROW_NUMBER":"814824","CASS_NUM":"51668832","SMP_TAKEN_DT":"12/16/2025","CONC":".065","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"CONTROL FILTER INVALID","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-12-16"},{"SOURCE_ROW_NUMBER":"607538","CASS_NUM":"51668827","SMP_TAKEN_DT":"12/16/2025","CONC":".028","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"CONTROL FILTER INVALID","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-12-16"},{"SOURCE_ROW_NUMBER":"440880","CASS_NUM":"51668826","SMP_TAKEN_DT":"12/16/2025","CONC":".031","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"CONTROL FILTER INVALID","OCC_CD_DESC":"HIGHWALL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-12-16"},{"SOURCE_ROW_NUMBER":"1453901","CASS_NUM":"58568258","SMP_TAKEN_DT":"11/5/2025","CONC":".129","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"STRIPPING SHOVEL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-11-05"},{"SOURCE_ROW_NUMBER":"1290523","CASS_NUM":"58568296","SMP_TAKEN_DT":"11/5/2025","CONC":".155","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHWALL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-11-05"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":2,"firstDate":"2014-08-22","lastDate":"2016-06-20","metrics":{"linkedIssuances":2},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":4,"firstDate":"2009-01-06","lastDate":"2017-01-11","metrics":{"decisions":4,"ssChanged":1,"recentRows":0,"decisionPenalty":12216,"proposedPenalty":71574},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"210668","CITATION_NO":"9064114","CITATION_ISSUE_DT":"01/11/2017","DOCKET_NO":"WEVA 2017-0285","DECISION_DT":"08/30/2017","CFR_STANDARD_CODE":"77.205(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"116.00","DECISION_PENALTY_AMT":"116.00","sourceDate":"2017-01-11"},{"SOURCE_ROW_NUMBER":"266524","CITATION_NO":"9014260","CITATION_ISSUE_DT":"03/29/2016","DOCKET_NO":"WEVA 2016-0523","DECISION_DT":"07/25/2017","CFR_STANDARD_CODE":"77.1713(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"70000.00","DECISION_PENALTY_AMT":"12000.00","sourceDate":"2016-03-29"},{"SOURCE_ROW_NUMBER":"10163","CITATION_NO":"6620406","CITATION_ISSUE_DT":"01/07/2009","DOCKET_NO":"WEVA 2009-1432","DECISION_DT":"03/08/2011","CFR_STANDARD_CODE":"48.26(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2009-01-07"},{"SOURCE_ROW_NUMBER":"181659","CITATION_NO":"6620407","CITATION_ISSUE_DT":"01/06/2009","DOCKET_NO":"WEVA 2009-1432","DECISION_DT":"03/08/2011","CFR_STANDARD_CODE":"48.27(a)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1337.00","DECISION_PENALTY_AMT":".00","sourceDate":"2009-01-06"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":872,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":7,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":171,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":6,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":5,"firstDate":"2008-12-04","lastDate":"2026-04-02","metrics":{"recentRows":3,"currentOperatorTenures":2,"completedOperatorTenures":3},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":58,"firstDate":"2009-01-05","lastDate":"2026-07-13","metrics":{"inspectors":88,"recentRows":18,"onSiteHours":1662.25,"inspectionHours":2727.5,"inspectionSamples":187},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"422049","EVENT_NO":"F0170F2","INSPECTION_BEGIN_DT":"07/13/2026","INSPECTION_END_DT":"07/28/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"73","SUM_TOTAL_ON_SITE_HOURS":"44.5","sourceDate":"2026-07-13"},{"SOURCE_ROW_NUMBER":"222050","EVENT_NO":"F02A948","INSPECTION_BEGIN_DT":"10/08/2025","INSPECTION_END_DT":"12/03/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"85.25","SUM_TOTAL_ON_SITE_HOURS":"60.5","sourceDate":"2025-10-08"},{"SOURCE_ROW_NUMBER":"133223","EVENT_NO":"F00C684","INSPECTION_BEGIN_DT":"06/04/2025","INSPECTION_END_DT":"08/19/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"117.5","SUM_TOTAL_ON_SITE_HOURS":"73.5","sourceDate":"2025-06-04"},{"SOURCE_ROW_NUMBER":"685323","EVENT_NO":"F00937B","INSPECTION_BEGIN_DT":"02/04/2025","INSPECTION_END_DT":"03/11/2025","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"23.75","SUM_TOTAL_ON_SITE_HOURS":"8.25","sourceDate":"2025-02-04"},{"SOURCE_ROW_NUMBER":"546800","EVENT_NO":"7033430","INSPECTION_BEGIN_DT":"11/04/2024","INSPECTION_END_DT":"11/26/2024","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"30","SUM_TOTAL_ON_SITE_HOURS":"16.25","sourceDate":"2024-11-04"},{"SOURCE_ROW_NUMBER":"1149692","EVENT_NO":"F00935F","INSPECTION_BEGIN_DT":"10/08/2024","INSPECTION_END_DT":"10/09/2024","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.75","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2024-10-08"},{"SOURCE_ROW_NUMBER":"282255","EVENT_NO":"7004339","INSPECTION_BEGIN_DT":"05/22/2024","INSPECTION_END_DT":"05/22/2024","ACTIVITY_CODE":"E17","ACTIVITY":"Special Emphasis Programs","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.25","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2024-05-22"},{"SOURCE_ROW_NUMBER":"646527","EVENT_NO":"7048469","INSPECTION_BEGIN_DT":"05/10/2024","INSPECTION_END_DT":"06/01/2024","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"60.5","SUM_TOTAL_ON_SITE_HOURS":"36.5","sourceDate":"2024-05-10"},{"SOURCE_ROW_NUMBER":"598910","EVENT_NO":"7049084","INSPECTION_BEGIN_DT":"03/22/2024","INSPECTION_END_DT":"03/22/2024","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13.25","SUM_TOTAL_ON_SITE_HOURS":"11","sourceDate":"2024-03-22"},{"SOURCE_ROW_NUMBER":"742578","EVENT_NO":"7048434","INSPECTION_BEGIN_DT":"11/02/2023","INSPECTION_END_DT":"11/08/2023","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"5.75","sourceDate":"2023-11-02"},{"SOURCE_ROW_NUMBER":"175409","EVENT_NO":"7048435","INSPECTION_BEGIN_DT":"11/02/2023","INSPECTION_END_DT":"01/11/2024","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"48","SUM_TOTAL_ON_SITE_HOURS":"28.5","sourceDate":"2023-11-02"},{"SOURCE_ROW_NUMBER":"737878","EVENT_NO":"7034078","INSPECTION_BEGIN_DT":"05/03/2023","INSPECTION_END_DT":"08/23/2023","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"96","SUM_TOTAL_ON_SITE_HOURS":"62.5","sourceDate":"2023-05-03"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":71,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2026-Q2":{"hours":7509,"employees":11,"production":150},"2026-Q1":{"hours":21044,"employees":17,"production":11225},"2025-Q4":{"hours":25328,"employees":20,"production":27869},"2025-Q3":{"hours":9552,"employees":17,"production":17768},"2025-Q2":{"hours":8642,"employees":13,"production":25385},"2025-Q1":{"hours":8025,"employees":12,"production":6634},"2024-Q4":{"hours":3162,"employees":5,"production":3401},"2024-Q3":{"hours":7370,"employees":11,"production":7328},"2024-Q2":{"hours":26278,"employees":35,"production":24494},"2024-Q1":{"hours":29058,"employees":41,"production":34473},"2023-Q4":{"hours":24929,"employees":39,"production":37704},"2023-Q3":{"hours":20674,"employees":30,"production":40306}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":19,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017":{"hours":83049,"employees":27,"production":138016},"2018":{"hours":56960,"employees":17,"production":60522},"2019":{"hours":62520,"employees":29,"production":189123},"2020":{"hours":151293,"employees":59,"production":340895},"2021":{"hours":152463,"employees":52,"production":263282},"2022":{"hours":110209,"employees":40,"production":151307},"2023":{"hours":88605,"employees":33,"production":151961},"2024":{"hours":65868,"employees":23,"production":69696},"2025":{"hours":51547,"employees":16,"production":77656},"2026":{"hours":28553,"employees":14,"production":11375}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":106,"firstDate":"2009-07-22","lastDate":"2025-11-05","metrics":{"recentRows":32,"doseOver100":2,"actDoseTotal":3515,"pelDoseTotal":1217},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"264595","EVENT_NO":"F02A948","SURVEY_DATE":"11/05/2025","OCCUPATION_CD_DESC":"STRIPPING SHOVEL OPERATOR","MACHINE_CD":"35","ACT_DOSE_85":"18","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2025-11-05"},{"SOURCE_ROW_NUMBER":"264594","EVENT_NO":"F02A948","SURVEY_DATE":"11/05/2025","OCCUPATION_CD_DESC":"HIGHWALL DRILL OPERATOR","MACHINE_CD":"21","ACT_DOSE_85":"21","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2025-11-05"},{"SOURCE_ROW_NUMBER":"264593","EVENT_NO":"F02A948","SURVEY_DATE":"11/05/2025","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"41","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2025-11-05"},{"SOURCE_ROW_NUMBER":"264592","EVENT_NO":"F02A948","SURVEY_DATE":"10/15/2025","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"11","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2025-10-15"},{"SOURCE_ROW_NUMBER":"264591","EVENT_NO":"F02A948","SURVEY_DATE":"10/15/2025","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","ACT_DOSE_85":"28","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2025-10-15"},{"SOURCE_ROW_NUMBER":"264590","EVENT_NO":"F02A948","SURVEY_DATE":"10/15/2025","OCCUPATION_CD_DESC":"STRIPPING SHOVEL OPERATOR","MACHINE_CD":"35","ACT_DOSE_85":"16","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2025-10-15"},{"SOURCE_ROW_NUMBER":"264589","EVENT_NO":"F02A948","SURVEY_DATE":"10/15/2025","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","ACT_DOSE_85":"16","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2025-10-15"},{"SOURCE_ROW_NUMBER":"264588","EVENT_NO":"F02A948","SURVEY_DATE":"10/15/2025","OCCUPATION_CD_DESC":"HIGHWALL DRILL OPERATOR","MACHINE_CD":"21","ACT_DOSE_85":"7","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2025-10-15"},{"SOURCE_ROW_NUMBER":"264587","EVENT_NO":"F00C684","SURVEY_DATE":"06/17/2025","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"40","PEL_DOSE_90":"27","SURVEY_TYPE":"I","sourceDate":"2025-06-17"},{"SOURCE_ROW_NUMBER":"264586","EVENT_NO":"F00C684","SURVEY_DATE":"06/17/2025","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","ACT_DOSE_85":"11","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2025-06-17"},{"SOURCE_ROW_NUMBER":"264585","EVENT_NO":"F00C684","SURVEY_DATE":"06/17/2025","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","ACT_DOSE_85":"7","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2025-06-17"},{"SOURCE_ROW_NUMBER":"264584","EVENT_NO":"F00C684","SURVEY_DATE":"06/17/2025","OCCUPATION_CD_DESC":"HIGHWALL DRILL OPERATOR","MACHINE_CD":"21","ACT_DOSE_85":"24","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2025-06-17"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":52,"firstDate":"2014-10-24","lastDate":"2025-11-05","metrics":{"recentRows":18,"voidSamples":0,"maxQuartzPct":40.6,"validSamples":52,"quartzPctTotal":712.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"134044","CASSETTE_NO":"58568296","SAMPLE_DT":"11/05/2025","QUARTZ_PCT":"10.1","QUARTZ_MICROGRAMS":"15","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-11-05"},{"SOURCE_ROW_NUMBER":"92348","CASSETTE_NO":"58568242","SAMPLE_DT":"11/05/2025","QUARTZ_PCT":"26.1","QUARTZ_MICROGRAMS":"69","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-11-05"},{"SOURCE_ROW_NUMBER":"68348","CASSETTE_NO":"58568391","SAMPLE_DT":"10/15/2025","QUARTZ_PCT":"02.2","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-10-15"},{"SOURCE_ROW_NUMBER":"113912","CASSETTE_NO":"58568929","SAMPLE_DT":"06/17/2025","QUARTZ_PCT":"29.2","QUARTZ_MICROGRAMS":"42","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-06-17"},{"SOURCE_ROW_NUMBER":"35792","CASSETTE_NO":"58482973","SAMPLE_DT":"05/14/2024","QUARTZ_PCT":"21.3","QUARTZ_MICROGRAMS":"294","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2024-05-14"},{"SOURCE_ROW_NUMBER":"95956","CASSETTE_NO":"58532803","SAMPLE_DT":"03/22/2024","QUARTZ_PCT":"12.4","QUARTZ_MICROGRAMS":"21","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2024-03-22"},{"SOURCE_ROW_NUMBER":"73117","CASSETTE_NO":"58480711","SAMPLE_DT":"05/19/2023","QUARTZ_PCT":"32.0","QUARTZ_MICROGRAMS":"47","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2023-05-19"},{"SOURCE_ROW_NUMBER":"78933","CASSETTE_NO":"58475932","SAMPLE_DT":"01/05/2023","QUARTZ_PCT":"34.9","QUARTZ_MICROGRAMS":"59","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2023-01-05"},{"SOURCE_ROW_NUMBER":"75248","CASSETTE_NO":"58475975","SAMPLE_DT":"11/09/2022","QUARTZ_PCT":"21.2","QUARTZ_MICROGRAMS":"36","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2022-11-09"},{"SOURCE_ROW_NUMBER":"43744","CASSETTE_NO":"58475972","SAMPLE_DT":"11/09/2022","QUARTZ_PCT":"03.5","QUARTZ_MICROGRAMS":"16","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2022-11-09"},{"SOURCE_ROW_NUMBER":"33390","CASSETTE_NO":"58475898","SAMPLE_DT":"11/09/2022","QUARTZ_PCT":"26.5","QUARTZ_MICROGRAMS":"35","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2022-11-09"},{"SOURCE_ROW_NUMBER":"96878","CASSETTE_NO":"58453128","SAMPLE_DT":"05/03/2022","QUARTZ_PCT":"21.0","QUARTZ_MICROGRAMS":"25","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2022-05-03"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":171,"firstDate":"2009-01-07","lastDate":"2026-07-15","metrics":{"ss":47,"amountDue":66661,"contested":1,"amountPaid":47040,"recentRows":83,"section104d":2,"unterminated":0,"proposedPenalty":127027},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2952138","VIOLATION_NO":"5024562","VIOLATION_ISSUE_DT":"07/15/2026","SIG_SUB":"Y","PART_SECTION":"77.1007(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/22/2026","PROPOSED_PENALTY":"193","AMOUNT_DUE":"193","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-07-15"},{"SOURCE_ROW_NUMBER":"2952137","VIOLATION_NO":"5024561","VIOLATION_ISSUE_DT":"07/15/2026","SIG_SUB":"Y","PART_SECTION":"72.620","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/22/2026","PROPOSED_PENALTY":"432","AMOUNT_DUE":"432","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-07-15"},{"SOURCE_ROW_NUMBER":"2952163","VIOLATION_NO":"5090783","VIOLATION_ISSUE_DT":"11/18/2025","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/19/2025","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2025-11-18"},{"SOURCE_ROW_NUMBER":"2952162","VIOLATION_NO":"5090782","VIOLATION_ISSUE_DT":"11/18/2025","SIG_SUB":"N","PART_SECTION":"77.1109(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/18/2025","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2025-11-18"},{"SOURCE_ROW_NUMBER":"2952161","VIOLATION_NO":"5090781","VIOLATION_ISSUE_DT":"11/18/2025","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/19/2025","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2025-11-18"},{"SOURCE_ROW_NUMBER":"2952160","VIOLATION_NO":"5090772","VIOLATION_ISSUE_DT":"11/03/2025","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/05/2025","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2025-11-03"},{"SOURCE_ROW_NUMBER":"2952159","VIOLATION_NO":"5090769","VIOLATION_ISSUE_DT":"10/27/2025","SIG_SUB":"Y","PART_SECTION":"77.1001","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/27/2025","PROPOSED_PENALTY":"226","AMOUNT_DUE":"226","AMOUNT_PAID":"226","CONTESTED_IND":"N","sourceDate":"2025-10-27"},{"SOURCE_ROW_NUMBER":"2952158","VIOLATION_NO":"5090762","VIOLATION_ISSUE_DT":"10/20/2025","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/23/2025","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2025-10-20"},{"SOURCE_ROW_NUMBER":"2952157","VIOLATION_NO":"5090761","VIOLATION_ISSUE_DT":"10/20/2025","SIG_SUB":"N","PART_SECTION":"77.1103(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/20/2025","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2025-10-20"},{"SOURCE_ROW_NUMBER":"2952156","VIOLATION_NO":"5090760","VIOLATION_ISSUE_DT":"10/15/2025","SIG_SUB":"N","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/20/2025","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2025-10-15"},{"SOURCE_ROW_NUMBER":"2952155","VIOLATION_NO":"5090759","VIOLATION_ISSUE_DT":"10/15/2025","SIG_SUB":"N","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/27/2025","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2025-10-15"},{"SOURCE_ROW_NUMBER":"2952154","VIOLATION_NO":"5090758","VIOLATION_ISSUE_DT":"10/08/2025","SIG_SUB":"N","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/23/2025","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2025-10-08"}]}],"safety":{"href":"/api/v1/mines/4609311/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609311/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":{"averageEmployees":23,"companyType":"Independent Producer Operator","components":[{"averageEmployees":23,"laborHours":65868,"mineType":"Surface","productionTons":69696}],"county":"Mercer","laborHours":65868,"mineName":"Mine No. 1","mineType":"Surface","mshaId":"4609311","operatingAddress":"150 Courthouse Road, Suite 302, Princeton, WV 24740","operatingCompany":"Onyx Energy, Llc","operationType":"Mine only","productionTons":69696,"reportedRows":1,"sourceUrl":"https://www.eia.gov/coal/data/public/xls/coalpublic2024.xlsx","state":"West Virginia (Southern)","status":"Active","supplyRegion":"Appalachia Central","union":"","year":2024},"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Drilling; general.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-K/section-77.1007","part":"77","subchapter":"O","subpart":"K","id":"77.1007","citation":"30 CFR 77.1007","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Drill dust control at surface mines and surface areas of underground mines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-72/subpart-E/section-72.620","part":"72","subchapter":"O","subpart":"E","id":"72.620","citation":"30 CFR 72.620","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 72—HEALTH STANDARDS FOR COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":2},{"chapter":"I","heading":"Stripping; loose material.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-K/section-77.1001","part":"77","subchapter":"O","subpart":"K","id":"77.1001","citation":"30 CFR 77.1001","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":1},{"chapter":"I","heading":"Flammable liquids; storage.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1103","part":"77","subchapter":"O","subpart":"L","id":"77.1103","citation":"30 CFR 77.1103","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":3}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609311","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}