{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4609299","name":"Cedar Grove #1 Mine","status":"Temporarily Idled","status_date":"2019-09-23","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Logan","nearest_town":"Yolin","operator_id":"P21118","operator_name":"Aracoma Coal Company, LLC","controller_id":"0127321","controller_name":"Alpha Metallurgical Resources Inc","district":"C04","office":"Logan WV Field Office","employees":0,"latitude":37.803333,"longitude":-81.905},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":1689},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609299","name":"Cedar Grove #1 Mine"},"operator":{"type":"operator","id":"P21118","name":"Aracoma Coal Company, LLC"},"controller":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"mine","id":"4609299","name":"Cedar Grove #1 Mine"},"validFrom":"1990-09-01","validTo":"2011-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609299|C02508|1990-09-01|2011-05-31"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P21118","name":"Aracoma Coal Company, LLC"},"object":{"type":"mine","id":"4609299","name":"Cedar Grove #1 Mine"},"validFrom":"2008-07-25","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609299|P21118|2008-07-25|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"P21118","name":"Aracoma Coal Company, LLC"},"validFrom":"2008-07-25","validTo":"2011-05-31","current":false,"derived":true,"evidenceMineId":"4609299","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609299|P21118|2008-07-25|C02508|1990-09-01|59256"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"4609299","name":"Cedar Grove #1 Mine"},"validFrom":"2011-06-01","validTo":"2016-07-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609299|0041211|2011-06-01|2016-07-25"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P21118","name":"Aracoma Coal Company, LLC"},"validFrom":"2011-06-01","validTo":"2016-07-25","current":false,"derived":true,"evidenceMineId":"4609299","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609299|P21118|2008-07-25|0041211|2011-06-01|2215"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"mine","id":"4609299","name":"Cedar Grove #1 Mine"},"validFrom":"2016-07-26","validTo":"2018-11-08","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609299|0127923|2016-07-26|2018-11-08"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"operator","id":"P21118","name":"Aracoma Coal Company, LLC"},"validFrom":"2016-07-26","validTo":"2018-11-08","current":false,"derived":true,"evidenceMineId":"4609299","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609299|P21118|2008-07-25|0127923|2016-07-26|25310"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"mine","id":"4609299","name":"Cedar Grove #1 Mine"},"validFrom":"2018-11-09","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609299|0127321|2018-11-09|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"operator","id":"P21118","name":"Aracoma Coal Company, LLC"},"validFrom":"2018-11-09","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609299","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609299|P21118|2008-07-25|0127321|2018-11-09|24945"}}],"coverage":{"historyRecords":4,"edgeCount":9,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":9,"firstDate":"2011-01-22","lastDate":"2014-01-06","metrics":{"daysLost":458,"injuries":9,"fatalities":0,"recentRows":0,"restrictedDays":8,"contractorRecords":1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"188908","DOCUMENT_NO":"220140210053","ACCIDENT_DT":"01/06/2014","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"ELECTRICAL","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"106","NARRATIVE":"Employee was unplugging scoop battery bell when cable arched. He turned to leave the area (a normal movement) and twisted his knee. He finished his shift with no complaints, and came outside. Due to a reconstructive knee surgery from a earlier injury, he requested a report be filled out for precautionary measures.","sourceDate":"2014-01-06"},{"SOURCE_ROW_NUMBER":"77193","DOCUMENT_NO":"220122700011","ACCIDENT_DT":"09/14/2012","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"One of the employees picked up a rock and threw it while horse playing.  The rock struck another employee in the upper lip resulting in a laceration.","sourceDate":"2012-09-14"},{"SOURCE_ROW_NUMBER":"158890","DOCUMENT_NO":"220122370026","ACCIDENT_DT":"08/20/2012","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by powered moving object","OCCUPATION":"Stopping builder, Ventilation man, Mason man, Overcast","NO_INJURIES":"1","DAYS_LOST":"33","NARRATIVE":"Employee was helping roof bolt crew re-route roof bolt cable.  As they were moving the cable, a shuttle car came around a turn striking the employee into the rib.","sourceDate":"2012-08-20"},{"SOURCE_ROW_NUMBER":"106971","DOCUMENT_NO":"220122290022","ACCIDENT_DT":"08/14/2012","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was walking from the end of track towards the section when he stumbled.  As he fell, he hit his right cheek on the D-box causing a laceration.","sourceDate":"2012-08-14"},{"SOURCE_ROW_NUMBER":"102758","DOCUMENT_NO":"220121720002","ACCIDENT_DT":"06/09/2012","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Struck by rolling or sliding object","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"263","NARRATIVE":"Employee was recovering curtain when rib rolled and struck employee in back.","sourceDate":"2012-06-09"},{"SOURCE_ROW_NUMBER":"21275","DOCUMENT_NO":"220112840061","ACCIDENT_DT":"09/29/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was cutting tape off suction hose on the right roof bolter.  During this process, employee cut his hand between his thumb and index finger.","sourceDate":"2011-09-29"},{"SOURCE_ROW_NUMBER":"158889","DOCUMENT_NO":"220111610017","ACCIDENT_DT":"06/02/2011","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was trying to get a piece of stuck drill steel out of the drill chuck.  As he was pulling on the drill steel, he something felt something pop in his back causing him to fall to the ground.","sourceDate":"2011-06-02"},{"SOURCE_ROW_NUMBER":"150365","DOCUMENT_NO":"220110820028","ACCIDENT_DT":"03/09/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"ELECTRICAL","ACCIDENT_TYPE":"Contact with electrical current","OCCUPATION":"Welder","NO_INJURIES":"1","DAYS_LOST":"55","NARRATIVE":"Member was helping re-enter hi=line cable into the #5 belt head kva. member was holding the lead out of the way for the electrician. A malfunction in the #1 box allowed that particular lead to become energized, causing the member to receive a shock.","sourceDate":"2011-03-09"},{"SOURCE_ROW_NUMBER":"201818","DOCUMENT_NO":"220110350045","ACCIDENT_DT":"01/22/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Member was attempting to split a half header against a block, when he smashed his right middle finger causing a laceration.","sourceDate":"2011-01-22"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2019-09-23","lastDate":"2019-09-23","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":246,"firstDate":"2008-12-18","lastDate":"2014-02-04","metrics":{"ss":89,"delinquent":244,"recentRows":0,"paidPenalty":120018,"proposedPenalty":157291,"currentAssessment":133882},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1840656","VIOLATION_NO":"9012800","ISSUE_DT":"02/04/2014","CFR_STANDARD_CD":"75.333(d)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"285.00","CURRENT_ASSESSMENT_AMT":"285.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-02-04"},{"SOURCE_ROW_NUMBER":"1840655","VIOLATION_NO":"9012799","ISSUE_DT":"02/02/2014","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"207.00","CURRENT_ASSESSMENT_AMT":"207.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-02-02"},{"SOURCE_ROW_NUMBER":"1840654","VIOLATION_NO":"9012798","ISSUE_DT":"01/27/2014","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"117.00","CURRENT_ASSESSMENT_AMT":"117.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-01-27"},{"SOURCE_ROW_NUMBER":"1840653","VIOLATION_NO":"9012797","ISSUE_DT":"01/22/2014","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"392.00","CURRENT_ASSESSMENT_AMT":"392.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-01-22"},{"SOURCE_ROW_NUMBER":"1840652","VIOLATION_NO":"9012796","ISSUE_DT":"01/13/2014","CFR_STANDARD_CD":"75.604(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"392.00","CURRENT_ASSESSMENT_AMT":"392.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-01-13"},{"SOURCE_ROW_NUMBER":"1840651","VIOLATION_NO":"9012795","ISSUE_DT":"01/13/2014","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-01-13"},{"SOURCE_ROW_NUMBER":"1840650","VIOLATION_NO":"9012794","ISSUE_DT":"01/09/2014","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"243.00","CURRENT_ASSESSMENT_AMT":"243.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-01-09"},{"SOURCE_ROW_NUMBER":"1840649","VIOLATION_NO":"9012792","ISSUE_DT":"01/06/2014","CFR_STANDARD_CD":"75.1731(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2282.00","CURRENT_ASSESSMENT_AMT":"2282.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-01-06"},{"SOURCE_ROW_NUMBER":"1840648","VIOLATION_NO":"9012791","ISSUE_DT":"01/06/2014","CFR_STANDARD_CD":"75.605","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"117.00","CURRENT_ASSESSMENT_AMT":"117.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-01-06"},{"SOURCE_ROW_NUMBER":"1840647","VIOLATION_NO":"9012790","ISSUE_DT":"01/06/2014","CFR_STANDARD_CD":"75.1505(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1530.00","CURRENT_ASSESSMENT_AMT":"1530.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-01-06"},{"SOURCE_ROW_NUMBER":"1840646","VIOLATION_NO":"9012789","ISSUE_DT":"01/06/2014","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"873.00","CURRENT_ASSESSMENT_AMT":"873.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-01-06"},{"SOURCE_ROW_NUMBER":"1840645","VIOLATION_NO":"9012788","ISSUE_DT":"01/02/2014","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"308.00","CURRENT_ASSESSMENT_AMT":"308.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-01-02"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":79,"firstDate":"2011-03-07","lastDate":"2015-10-29","metrics":{"appeals":0,"decisions":79,"recentRows":0,"decisionPenalty":70484,"originalPenalty":98973},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"94709","VIOLATION_NO":"8082439","DOCKET_NO":"WEVA 2013-439","DECISION_DT":"10/29/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"9122.00","DECISION_PENALTY_AMT":"7297.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2015-10-29"},{"SOURCE_ROW_NUMBER":"94465","VIOLATION_NO":"8082438","DOCKET_NO":"WEVA 2013-439","DECISION_DT":"10/29/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"8209.00","DECISION_PENALTY_AMT":"6567.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2015-10-29"},{"SOURCE_ROW_NUMBER":"340311","VIOLATION_NO":"8082432","DOCKET_NO":"WEVA 2013-534","DECISION_DT":"07/30/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3996.00","DECISION_PENALTY_AMT":"2997.00","JUDGE_FIRST_NAME":"Jerold","JUDGE_LAST_NAME":"Feldman","sourceDate":"2015-07-30"},{"SOURCE_ROW_NUMBER":"340215","VIOLATION_NO":"8082435","DOCKET_NO":"WEVA 2013-534","DECISION_DT":"07/30/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"5503.00","DECISION_PENALTY_AMT":"3439.00","JUDGE_FIRST_NAME":"Jerold","JUDGE_LAST_NAME":"Feldman","sourceDate":"2015-07-30"},{"SOURCE_ROW_NUMBER":"339952","VIOLATION_NO":"8082436","DOCKET_NO":"WEVA 2013-534","DECISION_DT":"07/30/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"5503.00","DECISION_PENALTY_AMT":"3439.00","JUDGE_FIRST_NAME":"Jerold","JUDGE_LAST_NAME":"Feldman","sourceDate":"2015-07-30"},{"SOURCE_ROW_NUMBER":"318505","VIOLATION_NO":"8135888","DOCKET_NO":"WEVA 2012-1200","DECISION_DT":"10/01/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"243.00","DECISION_PENALTY_AMT":"243.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2014-10-01"},{"SOURCE_ROW_NUMBER":"318504","VIOLATION_NO":"8134232","DOCKET_NO":"WEVA 2012-1200","DECISION_DT":"10/01/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"362.00","DECISION_PENALTY_AMT":"253.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2014-10-01"},{"SOURCE_ROW_NUMBER":"82532","VIOLATION_NO":"8134227","DOCKET_NO":"WEVA 2012-1200","DECISION_DT":"10/01/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"243.00","DECISION_PENALTY_AMT":"243.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2014-10-01"},{"SOURCE_ROW_NUMBER":"82531","VIOLATION_NO":"8134224","DOCKET_NO":"WEVA 2012-1200","DECISION_DT":"10/01/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"207.00","DECISION_PENALTY_AMT":"145.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2014-10-01"},{"SOURCE_ROW_NUMBER":"341230","VIOLATION_NO":"7167281","DOCKET_NO":"WEVA 2013-647","DECISION_DT":"06/18/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"585.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2014-06-18"},{"SOURCE_ROW_NUMBER":"340781","VIOLATION_NO":"7167271","DOCKET_NO":"WEVA 2013-647","DECISION_DT":"06/18/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1026.00","DECISION_PENALTY_AMT":"616.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2014-06-18"},{"SOURCE_ROW_NUMBER":"338604","VIOLATION_NO":"8151768","DOCKET_NO":"WEVA 2013-440","DECISION_DT":"04/28/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1569.00","DECISION_PENALTY_AMT":"1569.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2014-04-28"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":560,"firstDate":"2009-02-06","lastDate":"2014-01-29","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":83,"validSamples":477,"maxConcentration":10.253,"concentrationTotal":390.429},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1381761","CASS_NUM":"58124168","SMP_TAKEN_DT":"1/29/2014","CONC":".954","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-01-29"},{"SOURCE_ROW_NUMBER":"1376291","CASS_NUM":"58124208","SMP_TAKEN_DT":"1/29/2014","CONC":".313","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-01-29"},{"SOURCE_ROW_NUMBER":"1321770","CASS_NUM":"58124215","SMP_TAKEN_DT":"1/29/2014","CONC":".125","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-01-29"},{"SOURCE_ROW_NUMBER":"1262870","CASS_NUM":"58124219","SMP_TAKEN_DT":"1/29/2014","CONC":".527","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-01-29"},{"SOURCE_ROW_NUMBER":"1244121","CASS_NUM":"58123885","SMP_TAKEN_DT":"1/29/2014","CONC":".283","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-01-29"},{"SOURCE_ROW_NUMBER":"1084566","CASS_NUM":"58124134","SMP_TAKEN_DT":"1/29/2014","CONC":"1.344","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ELECTRICIAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-01-29"},{"SOURCE_ROW_NUMBER":"1067974","CASS_NUM":"58124195","SMP_TAKEN_DT":"1/29/2014","CONC":".635","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-01-29"},{"SOURCE_ROW_NUMBER":"974499","CASS_NUM":"58123931","SMP_TAKEN_DT":"1/29/2014","CONC":".583","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-01-29"},{"SOURCE_ROW_NUMBER":"719051","CASS_NUM":"58124207","SMP_TAKEN_DT":"1/29/2014","CONC":".621","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-01-29"},{"SOURCE_ROW_NUMBER":"661102","CASS_NUM":"58124172","SMP_TAKEN_DT":"1/29/2014","CONC":".848","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-01-29"},{"SOURCE_ROW_NUMBER":"645460","CASS_NUM":"58124199","SMP_TAKEN_DT":"1/29/2014","CONC":".152","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-01-29"},{"SOURCE_ROW_NUMBER":"282420","CASS_NUM":"58123919","SMP_TAKEN_DT":"1/29/2014","CONC":".202","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-01-29"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":3,"firstDate":"2012-10-26","lastDate":"2013-05-07","metrics":{"linkedIssuances":3},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":79,"firstDate":"2009-07-07","lastDate":"2013-01-22","metrics":{"decisions":79,"ssChanged":51,"recentRows":0,"decisionPenalty":70484,"proposedPenalty":98973},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"86032","CITATION_NO":"7167281","CITATION_ISSUE_DT":"01/22/2013","DOCKET_NO":"WEVA 2013-647","DECISION_DT":"06/18/2014","CFR_STANDARD_CODE":"75.211(c)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"585.00","sourceDate":"2013-01-22"},{"SOURCE_ROW_NUMBER":"318040","CITATION_NO":"7167271","CITATION_ISSUE_DT":"01/08/2013","DOCKET_NO":"WEVA 2013-647","DECISION_DT":"06/18/2014","CFR_STANDARD_CODE":"75.1731(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1026.00","DECISION_PENALTY_AMT":"616.00","sourceDate":"2013-01-08"},{"SOURCE_ROW_NUMBER":"86309","CITATION_NO":"8082449","CITATION_ISSUE_DT":"08/27/2012","DOCKET_NO":"WEVA 2013-74","DECISION_DT":"06/20/2013","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"6996.00","DECISION_PENALTY_AMT":"2500.00","sourceDate":"2012-08-27"},{"SOURCE_ROW_NUMBER":"368104","CITATION_NO":"8082446","CITATION_ISSUE_DT":"08/22/2012","DOCKET_NO":"WEVA 2013-74","DECISION_DT":"06/20/2013","CFR_STANDARD_CODE":"75.604(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"745.00","DECISION_PENALTY_AMT":"400.00","sourceDate":"2012-08-22"},{"SOURCE_ROW_NUMBER":"259199","CITATION_NO":"8082447","CITATION_ISSUE_DT":"08/22/2012","DOCKET_NO":"WEVA 2013-74","DECISION_DT":"06/20/2013","CFR_STANDARD_CODE":"75.1107-16(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"807.00","DECISION_PENALTY_AMT":"807.00","sourceDate":"2012-08-22"},{"SOURCE_ROW_NUMBER":"89833","CITATION_NO":"8082448","CITATION_ISSUE_DT":"08/22/2012","DOCKET_NO":"WEVA 2013-74","DECISION_DT":"06/20/2013","CFR_STANDARD_CODE":"75.1731(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1304.00","DECISION_PENALTY_AMT":"600.00","sourceDate":"2012-08-22"},{"SOURCE_ROW_NUMBER":"372510","CITATION_NO":"8082439","CITATION_ISSUE_DT":"07/26/2012","DOCKET_NO":"WEVA 2013-439","DECISION_DT":"10/29/2015","CFR_STANDARD_CODE":"75.360(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"9122.00","DECISION_PENALTY_AMT":"7297.00","sourceDate":"2012-07-26"},{"SOURCE_ROW_NUMBER":"29852","CITATION_NO":"8082438","CITATION_ISSUE_DT":"07/26/2012","DOCKET_NO":"WEVA 2013-439","DECISION_DT":"10/29/2015","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"8209.00","DECISION_PENALTY_AMT":"6567.00","sourceDate":"2012-07-26"},{"SOURCE_ROW_NUMBER":"425141","CITATION_NO":"8082436","CITATION_ISSUE_DT":"07/23/2012","DOCKET_NO":"WEVA 2013-534","DECISION_DT":"07/30/2015","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"5503.00","DECISION_PENALTY_AMT":"3439.00","sourceDate":"2012-07-23"},{"SOURCE_ROW_NUMBER":"28685","CITATION_NO":"8082435","CITATION_ISSUE_DT":"07/23/2012","DOCKET_NO":"WEVA 2013-534","DECISION_DT":"07/30/2015","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"5503.00","DECISION_PENALTY_AMT":"3439.00","sourceDate":"2012-07-23"},{"SOURCE_ROW_NUMBER":"259200","CITATION_NO":"8082432","CITATION_ISSUE_DT":"07/18/2012","DOCKET_NO":"WEVA 2013-534","DECISION_DT":"07/30/2015","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3996.00","DECISION_PENALTY_AMT":"2997.00","sourceDate":"2012-07-18"},{"SOURCE_ROW_NUMBER":"424746","CITATION_NO":"8082430","CITATION_ISSUE_DT":"06/25/2012","DOCKET_NO":"WEVA 2013-440","DECISION_DT":"04/28/2014","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"6458.00","DECISION_PENALTY_AMT":"4064.00","sourceDate":"2012-06-25"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":114,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":26,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":4,"firstDate":"2008-07-25","lastDate":"2008-07-25","metrics":{"recentRows":0,"currentOperatorTenures":4,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":72,"firstDate":"2008-12-16","lastDate":"2026-09-29","metrics":{"inspectors":123,"recentRows":3,"onSiteHours":1911.5,"inspectionHours":2978.75,"inspectionSamples":556},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"612282","EVENT_NO":"F026044","INSPECTION_BEGIN_DT":"09/29/2026","INSPECTION_END_DT":"09/29/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.25","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2026-09-29"},{"SOURCE_ROW_NUMBER":"176146","EVENT_NO":"F025BE5","INSPECTION_BEGIN_DT":"06/25/2026","INSPECTION_END_DT":"06/25/2026","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2026-06-25"},{"SOURCE_ROW_NUMBER":"1057684","EVENT_NO":"7048308","INSPECTION_BEGIN_DT":"03/31/2025","INSPECTION_END_DT":"03/31/2025","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2025-03-31"},{"SOURCE_ROW_NUMBER":"89938","EVENT_NO":"7009765","INSPECTION_BEGIN_DT":"10/13/2020","INSPECTION_END_DT":"10/13/2020","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2020-10-13"},{"SOURCE_ROW_NUMBER":"421011","EVENT_NO":"7016195","INSPECTION_BEGIN_DT":"08/06/2020","INSPECTION_END_DT":"08/06/2020","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2020-08-06"},{"SOURCE_ROW_NUMBER":"292681","EVENT_NO":"7009482","INSPECTION_BEGIN_DT":"07/01/2019","INSPECTION_END_DT":"07/01/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"4.25","sourceDate":"2019-07-01"},{"SOURCE_ROW_NUMBER":"644538","EVENT_NO":"7003299","INSPECTION_BEGIN_DT":"04/01/2019","INSPECTION_END_DT":"04/01/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"2.25","sourceDate":"2019-04-01"},{"SOURCE_ROW_NUMBER":"87070","EVENT_NO":"7003078","INSPECTION_BEGIN_DT":"01/10/2019","INSPECTION_END_DT":"01/10/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2019-01-10"},{"SOURCE_ROW_NUMBER":"1055278","EVENT_NO":"7003073","INSPECTION_BEGIN_DT":"10/02/2018","INSPECTION_END_DT":"10/03/2018","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2018-10-02"},{"SOURCE_ROW_NUMBER":"858429","EVENT_NO":"7004662","INSPECTION_BEGIN_DT":"08/30/2018","INSPECTION_END_DT":"08/30/2018","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2018-08-30"},{"SOURCE_ROW_NUMBER":"418493","EVENT_NO":"7004653","INSPECTION_BEGIN_DT":"04/23/2018","INSPECTION_END_DT":"04/23/2018","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2018-04-23"},{"SOURCE_ROW_NUMBER":"626332","EVENT_NO":"7007627","INSPECTION_BEGIN_DT":"04/06/2018","INSPECTION_END_DT":"04/06/2018","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2018-04-06"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":141,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2026-Q2":{"hours":0,"employees":0,"production":0},"2026-Q1":{"hours":0,"employees":0,"production":0},"2025-Q4":{"hours":0,"employees":0,"production":0},"2025-Q3":{"hours":0,"employees":0,"production":0},"2025-Q2":{"hours":0,"employees":0,"production":0},"2025-Q1":{"hours":0,"employees":0,"production":0},"2024-Q4":{"hours":0,"employees":0,"production":0},"2024-Q3":{"hours":0,"employees":0,"production":0},"2024-Q2":{"hours":0,"employees":0,"production":0},"2024-Q1":{"hours":0,"employees":0,"production":0},"2023-Q4":{"hours":0,"employees":0,"production":0},"2023-Q3":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":15,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2008":{"hours":210,"employees":1,"production":0},"2009":{"hours":51702,"employees":31,"production":166036},"2010":{"hours":11972,"employees":8,"production":12985},"2011":{"hours":120584,"employees":53,"production":327940},"2012":{"hours":136439,"employees":60,"production":409320},"2013":{"hours":155189,"employees":75,"production":465789},"2014":{"hours":35180,"employees":47,"production":61160},"2026":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":56,"firstDate":"2009-04-08","lastDate":"2013-05-07","metrics":{"recentRows":0,"doseOver100":12,"actDoseTotal":3895,"pelDoseTotal":3247},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"264313","EVENT_NO":"6298168","SURVEY_DATE":"05/07/2013","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"50","PEL_DOSE_90":"29","SURVEY_TYPE":"I","sourceDate":"2013-05-07"},{"SOURCE_ROW_NUMBER":"264312","EVENT_NO":"6298168","SURVEY_DATE":"05/07/2013","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"54","PEL_DOSE_90":"20","SURVEY_TYPE":"I","sourceDate":"2013-05-07"},{"SOURCE_ROW_NUMBER":"264311","EVENT_NO":"6298168","SURVEY_DATE":"05/07/2013","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"104","PEL_DOSE_90":"81","SURVEY_TYPE":"I","sourceDate":"2013-05-07"},{"SOURCE_ROW_NUMBER":"264310","EVENT_NO":"6298168","SURVEY_DATE":"05/07/2013","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"109","PEL_DOSE_90":"82","SURVEY_TYPE":"I","sourceDate":"2013-05-07"},{"SOURCE_ROW_NUMBER":"264309","EVENT_NO":"6298168","SURVEY_DATE":"05/07/2013","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"119","PEL_DOSE_90":"90","SURVEY_TYPE":"I","sourceDate":"2013-05-07"},{"SOURCE_ROW_NUMBER":"264308","EVENT_NO":"6298168","SURVEY_DATE":"05/07/2013","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"110","PEL_DOSE_90":"77","SURVEY_TYPE":"I","sourceDate":"2013-05-07"},{"SOURCE_ROW_NUMBER":"264307","EVENT_NO":"6298168","SURVEY_DATE":"05/07/2013","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"108","PEL_DOSE_90":"82","SURVEY_TYPE":"I","sourceDate":"2013-05-07"},{"SOURCE_ROW_NUMBER":"264306","EVENT_NO":"6298168","SURVEY_DATE":"05/07/2013","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"45","PEL_DOSE_90":"25","SURVEY_TYPE":"I","sourceDate":"2013-05-07"},{"SOURCE_ROW_NUMBER":"264305","EVENT_NO":"6298168","SURVEY_DATE":"05/07/2013","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"104","PEL_DOSE_90":"82","SURVEY_TYPE":"I","sourceDate":"2013-05-07"},{"SOURCE_ROW_NUMBER":"264304","EVENT_NO":"6298168","SURVEY_DATE":"05/07/2013","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"124","PEL_DOSE_90":"92","SURVEY_TYPE":"I","sourceDate":"2013-05-07"},{"SOURCE_ROW_NUMBER":"264303","EVENT_NO":"6298168","SURVEY_DATE":"05/07/2013","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"90","PEL_DOSE_90":"59","SURVEY_TYPE":"I","sourceDate":"2013-05-07"},{"SOURCE_ROW_NUMBER":"264302","EVENT_NO":"6298168","SURVEY_DATE":"05/07/2013","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"60","PEL_DOSE_90":"26","SURVEY_TYPE":"I","sourceDate":"2013-05-07"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":29,"firstDate":"2009-02-06","lastDate":"2014-01-29","metrics":{"recentRows":0,"voidSamples":3,"maxQuartzPct":16.1,"validSamples":26,"quartzPctTotal":181.6},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"112981","CASSETTE_NO":"58123931","SAMPLE_DT":"01/29/2014","QUARTZ_PCT":"07.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-01-29"},{"SOURCE_ROW_NUMBER":"79336","CASSETTE_NO":"58124219","SAMPLE_DT":"01/29/2014","QUARTZ_PCT":"10.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-01-29"},{"SOURCE_ROW_NUMBER":"50920","CASSETTE_NO":"58013428","SAMPLE_DT":"10/30/2013","QUARTZ_PCT":"08.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-10-30"},{"SOURCE_ROW_NUMBER":"161492","CASSETTE_NO":"58002399","SAMPLE_DT":"07/16/2013","QUARTZ_PCT":"06.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-07-16"},{"SOURCE_ROW_NUMBER":"111738","CASSETTE_NO":"58003065","SAMPLE_DT":"07/16/2013","QUARTZ_PCT":"07.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-07-16"},{"SOURCE_ROW_NUMBER":"18444","CASSETTE_NO":"58002344","SAMPLE_DT":"07/16/2013","QUARTZ_PCT":"05.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-07-16"},{"SOURCE_ROW_NUMBER":"17696","CASSETTE_NO":"58007595","SAMPLE_DT":"02/14/2013","QUARTZ_PCT":"05.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-02-14"},{"SOURCE_ROW_NUMBER":"93903","CASSETTE_NO":"58007320","SAMPLE_DT":"01/30/2013","QUARTZ_PCT":"05.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-01-30"},{"SOURCE_ROW_NUMBER":"48535","CASSETTE_NO":"58007050","SAMPLE_DT":"01/30/2013","QUARTZ_PCT":"04.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-01-30"},{"SOURCE_ROW_NUMBER":"70169","CASSETTE_NO":"58006710","SAMPLE_DT":"01/16/2013","QUARTZ_PCT":"05.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-01-16"},{"SOURCE_ROW_NUMBER":"23397","CASSETTE_NO":"57972726","SAMPLE_DT":"11/28/2012","QUARTZ_PCT":"06.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-11-28"},{"SOURCE_ROW_NUMBER":"84103","CASSETTE_NO":"51201382","SAMPLE_DT":"10/17/2012","QUARTZ_PCT":"06.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-10-17"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":254,"firstDate":"2008-12-18","lastDate":"2014-02-04","metrics":{"ss":88,"amountDue":133882,"contested":12,"amountPaid":120018,"recentRows":0,"section104d":3,"unterminated":1,"proposedPenalty":157291},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2950741","VIOLATION_NO":"9012800","VIOLATION_ISSUE_DT":"02/04/2014","SIG_SUB":"N","PART_SECTION":"75.333(d)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"7","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/04/2014","PROPOSED_PENALTY":"285","AMOUNT_DUE":"285","AMOUNT_PAID":"285","CONTESTED_IND":"N","sourceDate":"2014-02-04"},{"SOURCE_ROW_NUMBER":"2950740","VIOLATION_NO":"9012799","VIOLATION_ISSUE_DT":"02/02/2014","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/02/2014","PROPOSED_PENALTY":"207","AMOUNT_DUE":"207","AMOUNT_PAID":"207","CONTESTED_IND":"N","sourceDate":"2014-02-02"},{"SOURCE_ROW_NUMBER":"2950739","VIOLATION_NO":"9012798","VIOLATION_ISSUE_DT":"01/27/2014","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/28/2014","PROPOSED_PENALTY":"117","AMOUNT_DUE":"117","AMOUNT_PAID":"117","CONTESTED_IND":"N","sourceDate":"2014-01-27"},{"SOURCE_ROW_NUMBER":"2950738","VIOLATION_NO":"9012797","VIOLATION_ISSUE_DT":"01/22/2014","SIG_SUB":"N","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/22/2014","PROPOSED_PENALTY":"392","AMOUNT_DUE":"392","AMOUNT_PAID":"392","CONTESTED_IND":"N","sourceDate":"2014-01-22"},{"SOURCE_ROW_NUMBER":"2950737","VIOLATION_NO":"9012796","VIOLATION_ISSUE_DT":"01/13/2014","SIG_SUB":"N","PART_SECTION":"75.604(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/13/2014","PROPOSED_PENALTY":"392","AMOUNT_DUE":"392","AMOUNT_PAID":"392","CONTESTED_IND":"N","sourceDate":"2014-01-13"},{"SOURCE_ROW_NUMBER":"2950736","VIOLATION_NO":"9012795","VIOLATION_ISSUE_DT":"01/13/2014","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"01/13/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-01-13"},{"SOURCE_ROW_NUMBER":"2950735","VIOLATION_NO":"9012794","VIOLATION_ISSUE_DT":"01/09/2014","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/13/2014","PROPOSED_PENALTY":"243","AMOUNT_DUE":"243","AMOUNT_PAID":"243","CONTESTED_IND":"N","sourceDate":"2014-01-09"},{"SOURCE_ROW_NUMBER":"2950734","VIOLATION_NO":"9012792","VIOLATION_ISSUE_DT":"01/06/2014","SIG_SUB":"Y","PART_SECTION":"75.1731(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"15","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/06/2014","PROPOSED_PENALTY":"2282","AMOUNT_DUE":"2282","AMOUNT_PAID":"2282","CONTESTED_IND":"N","sourceDate":"2014-01-06"},{"SOURCE_ROW_NUMBER":"2950733","VIOLATION_NO":"9012791","VIOLATION_ISSUE_DT":"01/06/2014","SIG_SUB":"N","PART_SECTION":"75.605","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/06/2014","PROPOSED_PENALTY":"117","AMOUNT_DUE":"117","AMOUNT_PAID":"117","CONTESTED_IND":"N","sourceDate":"2014-01-06"},{"SOURCE_ROW_NUMBER":"2950732","VIOLATION_NO":"9012790","VIOLATION_ISSUE_DT":"01/06/2014","SIG_SUB":"N","PART_SECTION":"75.1505(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"15","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/06/2014","PROPOSED_PENALTY":"1530","AMOUNT_DUE":"1530","AMOUNT_PAID":"1530","CONTESTED_IND":"N","sourceDate":"2014-01-06"},{"SOURCE_ROW_NUMBER":"2950731","VIOLATION_NO":"9012789","VIOLATION_ISSUE_DT":"01/06/2014","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"15","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/07/2014","PROPOSED_PENALTY":"873","AMOUNT_DUE":"873","AMOUNT_PAID":"873","CONTESTED_IND":"N","sourceDate":"2014-01-06"},{"SOURCE_ROW_NUMBER":"2950730","VIOLATION_NO":"9012788","VIOLATION_ISSUE_DT":"01/02/2014","SIG_SUB":"N","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/02/2014","PROPOSED_PENALTY":"308","AMOUNT_DUE":"308","AMOUNT_PAID":"308","CONTESTED_IND":"N","sourceDate":"2014-01-02"}]}],"safety":{"href":"/api/v1/mines/4609299/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609299/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.604","heading":"Permanent splicing of trailing cables.","id":"75.604","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.604","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"[Statutory Provisions]\n\nWhen permanent splices in trailing cables are made, they shall be:\n\n(a) Mechanically strong with adequate electrical conductivity and flexibility;\n\n(b) Effectively insulated and sealed so as to exclude moisture; and\n\n(c) Vulcanized or otherwise treated with suitable materials to provide flame-resistant qualities and good bonding to the outer jacket.\n\n(d) Made using splice kits accepted or approved by MSHA as flame resistant.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 57 FR 61223, Dec. 23, 1992]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1731","heading":"Maintenance of belt conveyors and belt conveyor entries.","id":"75.1731","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1731","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Damaged rollers, or other damaged belt conveyor components, which pose a fire hazard must be immediately repaired or replaced. All other damaged rollers, or other damaged belt conveyor components, must be repaired or replaced.\n\n(b) Conveyor belts must be properly aligned to prevent the moving belt from rubbing against the structure or components.\n\n(c) Materials shall not be allowed in the belt conveyor entry where the material may contribute to a frictional heating hazard.\n\n(d) Splicing of any approved conveyor belt must maintain flame-resistant properties of the belt.\n\n[73 FR 80616, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","heading":"Clamping of trailing cables to equipment.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.605","part":"75","subchapter":"O","subpart":"G","id":"75.605","citation":"30 CFR 75.605","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1505","heading":"Escapeway maps.","id":"75.1505","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-P/section-75.1505","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"P","subpartHeading":"Subpart P—Mine Emergencies","text":"(a) Content and accessibility. An escapeway map shall show the designated escapeways from the working sections or the miners' work stations to the surface or the exits at the bottom of the shaft or slope, refuge alternatives, and SCSR storage locations. The escapeway map shall be posted or readily accessible for all miners—\n\n(1) In each working section;\n\n(2) In each area where mechanized mining equipment is being installed or removed;\n\n(3) At the refuge alternative; and\n\n(4) At a surface location of the mine where miners congregate, such as at the mine bulletin board, bathhouse, or waiting room.\n\n(b) Keeping maps current. All maps shall be kept up-to-date and any change in route of travel, location of doors, location of refuge alternatives, or direction of airflow shall be shown on the maps by the end of the shift on which the change is made.\n\n(c) Informing affected miners. Miners underground on a shift when any such change is made shall be notified immediately of the change and other affected miners shall be informed of the change before entering the underground areas of the mine.\n\n[71 FR 71452, Dec. 8, 2006, as amended at 73 FR 80698, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609299","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}