{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4609294","name":"Washington Mine","status":"Abandoned","status_date":"2024-02-05","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Logan","nearest_town":"Amherstdale","operator_id":"0179133","operator_name":"Active Resources, Inc.","controller_id":"0164901","controller_name":"Jon  Nix","district":"C04","office":"Beckley District","employees":0,"latitude":37.761944,"longitude":-81.776389},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":9040},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609294","name":"Washington Mine"},"operator":{"type":"operator","id":"0179133","name":"Active Resources, Inc."},"controller":{"type":"controller","id":"0164901","name":"Jon  Nix"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"0056849","name":"Magnum Coal Company"},"object":{"type":"mine","id":"4609294","name":"Washington Mine"},"validFrom":"2007-08-15","validTo":"2008-07-22","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609294|0056849|2007-08-15|2008-07-22"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0082465","name":"Coyote Coal Company LLC"},"object":{"type":"mine","id":"4609294","name":"Washington Mine"},"validFrom":"2008-07-15","validTo":"2014-12-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609294|0082465|2008-07-15|2014-12-31"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0056849","name":"Magnum Coal Company"},"object":{"type":"operator","id":"0082465","name":"Coyote Coal Company LLC"},"validFrom":"2008-07-15","validTo":"2008-07-22","current":false,"derived":true,"evidenceMineId":"4609294","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609294|0082465|2008-07-15|0056849|2007-08-15|7528"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0071611","name":"Patriot Coal Corporation"},"object":{"type":"mine","id":"4609294","name":"Washington Mine"},"validFrom":"2008-07-23","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609294|0071611|2008-07-23|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0071611","name":"Patriot Coal Corporation"},"object":{"type":"operator","id":"0082465","name":"Coyote Coal Company LLC"},"validFrom":"2008-07-23","validTo":"2014-12-31","current":false,"derived":true,"evidenceMineId":"4609294","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609294|0082465|2008-07-15|0071611|2008-07-23|10408"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0109461","name":"Blackhawk Mining LLC"},"object":{"type":"mine","id":"4609294","name":"Washington Mine"},"validFrom":"2014-09-01","validTo":"2020-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609294|0109461|2014-09-01|2020-05-31"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0135215","name":"Hampden Coal, LLC"},"object":{"type":"mine","id":"4609294","name":"Washington Mine"},"validFrom":"2015-01-01","validTo":"2023-09-24","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609294|0135215|2015-01-01|2023-09-24"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0109461","name":"Blackhawk Mining LLC"},"object":{"type":"operator","id":"0135215","name":"Hampden Coal, LLC"},"validFrom":"2015-01-01","validTo":"2020-05-31","current":false,"derived":true,"evidenceMineId":"4609294","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609294|0135215|2015-01-01|0109461|2014-09-01|19869"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0158381","name":"Sev.en Global Investments a.s."},"object":{"type":"mine","id":"4609294","name":"Washington Mine"},"validFrom":"2020-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609294|0158381|2020-06-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0158381","name":"Sev.en Global Investments a.s."},"object":{"type":"operator","id":"0135215","name":"Hampden Coal, LLC"},"validFrom":"2020-06-01","validTo":"2023-09-24","current":false,"derived":true,"evidenceMineId":"4609294","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609294|0135215|2015-01-01|0158381|2020-06-01|32873"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0164901","name":"Jon  Nix"},"object":{"type":"mine","id":"4609294","name":"Washington Mine"},"validFrom":"2021-10-04","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609294|0164901|2021-10-04|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0179133","name":"Active Resources, Inc."},"object":{"type":"mine","id":"4609294","name":"Washington Mine"},"validFrom":"2023-09-25","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609294|0179133|2023-09-25|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0164901","name":"Jon  Nix"},"object":{"type":"operator","id":"0179133","name":"Active Resources, Inc."},"validFrom":"2023-09-25","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609294","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609294|0179133|2023-09-25|0164901|2021-10-04|34547"}}],"coverage":{"historyRecords":5,"edgeCount":13,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":49,"firstDate":"2015-07-30","lastDate":"2019-10-23","metrics":{"daysLost":5993,"injuries":41,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"240706","DOCUMENT_NO":"220193040004","ACCIDENT_DT":"10/23/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"32","NARRATIVE":"Employee stated that while attempting to remove the pin from the belt structure, the belt rail fell and the bottom roller hanger struck EE on top of EE's left foot.","sourceDate":"2019-10-23"},{"SOURCE_ROW_NUMBER":"8370","DOCUMENT_NO":"220192750013","ACCIDENT_DT":"09/25/2019","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee stated was attempting to remove the drill steel after drilling a hole in the top when a piece of draw rock struck employee on right forearm causing a laceration that required sutures.  IE did not miss any scheduled work due this incident.","sourceDate":"2019-09-25"},{"SOURCE_ROW_NUMBER":"16906","DOCUMENT_NO":"220191220002","ACCIDENT_DT":"04/24/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"31","NARRATIVE":"Employee stated that EE was attempting to bend a bolt to fit it into EE's drill mast when EE felt a pain in EE's lower back.","sourceDate":"2019-04-24"},{"SOURCE_ROW_NUMBER":"128532","DOCUMENT_NO":"220190880020","ACCIDENT_DT":"03/19/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Motorman, Motor person, Swamper, Switchman, Locomotive operator","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"Employee stated ee was attempting to shove the feeder shaft from the flat car to the end loader bucket by using knee when ee felt a pain in knee.","sourceDate":"2019-03-19"},{"SOURCE_ROW_NUMBER":"206198","DOCUMENT_NO":"220190740020","ACCIDENT_DT":"03/05/2019","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Safety director","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee stated that the GT568 4 Wheeler jumped into high tram causing employee to strike head on the steering wheel.  This caused a laceration to the forehead that required sutures.  Employee did not miss any scheduled work days due to this incident.","sourceDate":"2019-03-05"},{"SOURCE_ROW_NUMBER":"64121","DOCUMENT_NO":"220190510024","ACCIDENT_DT":"02/12/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"24","NARRATIVE":"Employee stated was attempting to remove a rock from the continuous miner with a pry bar when the rock slid off onto EE's left foot.  This caused a fracture to the left foot.","sourceDate":"2019-02-12"},{"SOURCE_ROW_NUMBER":"253562","DOCUMENT_NO":"220183110014","ACCIDENT_DT":"10/25/2018","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"271","NARRATIVE":"Employee was loading bolts into the tray when they felt a pain in their back. Employee returned to work on 10/26/18, but was taken off work by a physician on 10/29/18 awaiting an MRI.","sourceDate":"2018-10-25"},{"SOURCE_ROW_NUMBER":"219171","DOCUMENT_NO":"220183040013","ACCIDENT_DT":"10/15/2018","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Miner, NEC","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"***We tried to report this Injury on 10/23/2018 but got caught kicked out of the MSHA site under a specific login*** Employee was loading cinder blocks into a scoop and another employee put blocks into the scoop and the blocks smashed injured employee's right middle finger.","sourceDate":"2018-10-15"},{"SOURCE_ROW_NUMBER":"72729","DOCUMENT_NO":"220182560003","ACCIDENT_DT":"09/05/2018","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A fall occurred at the mine on the MB #2 Panel in an intersection between the #2 and #3 entries inby the section tailpiece.","sourceDate":"2018-09-05"},{"SOURCE_ROW_NUMBER":"154587","DOCUMENT_NO":"220181450015","ACCIDENT_DT":"05/16/2018","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by powered moving object","OCCUPATION":"LW Propman, Propman helper, Move crew if LW, Move-up man, Jacksetter, Advanceman LW helper","NO_INJURIES":"1","DAYS_LOST":"90","NARRATIVE":"Employee stated that ee was attempting to hook a chain to the scoop bucket when the operator of the scoop inadvertently lowered the scoop bucket onto left leg just above knee.","sourceDate":"2018-05-16"},{"SOURCE_ROW_NUMBER":"16905","DOCUMENT_NO":"220180940026","ACCIDENT_DT":"03/26/2018","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Section foreman, Bullgang foreman, Labor foreman, Leadman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"420","NARRATIVE":"Employee stated that as EE was kneeling near the rib on the #1 Section during the last lift of pillaring on the solid block in the #1 entry, a section of rib fell out and struck EE in the lower back.","sourceDate":"2018-03-26"},{"SOURCE_ROW_NUMBER":"145922","DOCUMENT_NO":"220180460021","ACCIDENT_DT":"02/07/2018","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"The employee stated EE was attempting to make a belt splice when EE struck left middle finger with a hammer causing a laceration to the finger.","sourceDate":"2018-02-07"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2024-02-05","lastDate":"2024-02-05","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":1100,"firstDate":"2008-09-17","lastDate":"2020-03-30","metrics":{"ss":268,"delinquent":1062,"recentRows":0,"paidPenalty":740812.35,"proposedPenalty":992169,"currentAssessment":754848.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2823933","VIOLATION_NO":"9222082","ISSUE_DT":"03/30/2020","CFR_STANDARD_CD":"75.1713-2(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"3046.00","CURRENT_ASSESSMENT_AMT":"616.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-03-30"},{"SOURCE_ROW_NUMBER":"2823931","VIOLATION_NO":"9222080","ISSUE_DT":"01/08/2020","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"234.00","CURRENT_ASSESSMENT_AMT":"234.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-01-08"},{"SOURCE_ROW_NUMBER":"2812439","VIOLATION_NO":"9229024","ISSUE_DT":"12/10/2019","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"168.00","CURRENT_ASSESSMENT_AMT":"168.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-12-10"},{"SOURCE_ROW_NUMBER":"2812438","VIOLATION_NO":"9229023","ISSUE_DT":"12/10/2019","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"514.00","CURRENT_ASSESSMENT_AMT":"514.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-12-10"},{"SOURCE_ROW_NUMBER":"2812437","VIOLATION_NO":"9229022","ISSUE_DT":"12/10/2019","CFR_STANDARD_CD":"75.518","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-12-10"},{"SOURCE_ROW_NUMBER":"2812436","VIOLATION_NO":"9229021","ISSUE_DT":"12/10/2019","CFR_STANDARD_CD":"75.518","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-12-10"},{"SOURCE_ROW_NUMBER":"2812435","VIOLATION_NO":"9229020","ISSUE_DT":"12/10/2019","CFR_STANDARD_CD":"75.516","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"250.00","CURRENT_ASSESSMENT_AMT":"250.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-12-10"},{"SOURCE_ROW_NUMBER":"2812434","VIOLATION_NO":"9226274","ISSUE_DT":"10/07/2019","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"319.00","CURRENT_ASSESSMENT_AMT":"319.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-10-07"},{"SOURCE_ROW_NUMBER":"2812433","VIOLATION_NO":"9226273","ISSUE_DT":"10/06/2019","CFR_STANDARD_CD":"75.312(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"214.00","CURRENT_ASSESSMENT_AMT":"214.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-10-06"},{"SOURCE_ROW_NUMBER":"2812432","VIOLATION_NO":"9226272","ISSUE_DT":"10/06/2019","CFR_STANDARD_CD":"75.360(g)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-10-06"},{"SOURCE_ROW_NUMBER":"2812431","VIOLATION_NO":"9226267","ISSUE_DT":"10/01/2019","CFR_STANDARD_CD":"75.1714-4(c)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1242.00","CURRENT_ASSESSMENT_AMT":"1242.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-10-01"},{"SOURCE_ROW_NUMBER":"2812430","VIOLATION_NO":"9226266","ISSUE_DT":"10/01/2019","CFR_STANDARD_CD":"75.1714-3(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-10-01"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":609,"firstDate":"2011-12-22","lastDate":"2020-12-11","metrics":{"appeals":0,"decisions":609,"recentRows":0,"decisionPenalty":670341.5,"originalPenalty":907662},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"144620","VIOLATION_NO":"9222082","DOCKET_NO":"WEVA 2020-0427","DECISION_DT":"12/11/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3046.00","DECISION_PENALTY_AMT":"616.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2020-12-11"},{"SOURCE_ROW_NUMBER":"416990","VIOLATION_NO":"9222781","DOCKET_NO":"WEVA 2019-0680","DECISION_DT":"03/31/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2353.00","DECISION_PENALTY_AMT":"1483.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2020-03-31"},{"SOURCE_ROW_NUMBER":"141020","VIOLATION_NO":"9222783","DOCKET_NO":"WEVA 2019-0680","DECISION_DT":"03/31/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"7817.00","DECISION_PENALTY_AMT":"1578.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2020-03-31"},{"SOURCE_ROW_NUMBER":"140959","VIOLATION_NO":"9222782","DOCKET_NO":"WEVA 2019-0680","DECISION_DT":"03/31/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1057.00","DECISION_PENALTY_AMT":"1057.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2020-03-31"},{"SOURCE_ROW_NUMBER":"419253","VIOLATION_NO":"9226763","DOCKET_NO":"WEVA 2020-0142","DECISION_DT":"03/10/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"8468.00","DECISION_PENALTY_AMT":"3468.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"419252","VIOLATION_NO":"9226762","DOCKET_NO":"WEVA 2020-0142","DECISION_DT":"03/10/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"8468.00","DECISION_PENALTY_AMT":"3468.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"419251","VIOLATION_NO":"9226759","DOCKET_NO":"WEVA 2020-0142","DECISION_DT":"03/10/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"121.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"419250","VIOLATION_NO":"9226752","DOCKET_NO":"WEVA 2020-0142","DECISION_DT":"03/10/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"121.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"419249","VIOLATION_NO":"9226751","DOCKET_NO":"WEVA 2020-0142","DECISION_DT":"03/10/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"121.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"419248","VIOLATION_NO":"9226749","DOCKET_NO":"WEVA 2020-0142","DECISION_DT":"03/10/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3804.00","DECISION_PENALTY_AMT":"1500.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"419247","VIOLATION_NO":"9226748","DOCKET_NO":"WEVA 2020-0142","DECISION_DT":"03/10/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"214.00","DECISION_PENALTY_AMT":"214.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"419246","VIOLATION_NO":"9226746","DOCKET_NO":"WEVA 2020-0142","DECISION_DT":"03/10/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"474.00","DECISION_PENALTY_AMT":"474.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-03-10"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":4440,"firstDate":"2015-05-04","lastDate":"2019-10-07","metrics":{"recentRows":0,"cpdmSamples":3839,"voidSamples":1534,"validSamples":2906,"maxConcentration":106659.648,"concentrationTotal":108941.778},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2549617","SMP_TAKEN_DT":"10/7/2019","CONC":".775","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-10-07"},{"SOURCE_ROW_NUMBER":"2464034","SMP_TAKEN_DT":"10/7/2019","CONC":".638","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-10-07"},{"SOURCE_ROW_NUMBER":"2123214","SMP_TAKEN_DT":"10/7/2019","CONC":".209","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-10-07"},{"SOURCE_ROW_NUMBER":"2037179","SMP_TAKEN_DT":"10/7/2019","CONC":".063","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-10-07"},{"SOURCE_ROW_NUMBER":"1952866","SMP_TAKEN_DT":"10/7/2019","CONC":".268","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-10-07"},{"SOURCE_ROW_NUMBER":"1952588","SMP_TAKEN_DT":"10/7/2019","CONC":".656","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-10-07"},{"SOURCE_ROW_NUMBER":"1867629","SMP_TAKEN_DT":"10/7/2019","CONC":".2","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-10-07"},{"SOURCE_ROW_NUMBER":"1867628","SMP_TAKEN_DT":"10/7/2019","CONC":".094","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-10-07"},{"SOURCE_ROW_NUMBER":"2891273","SMP_TAKEN_DT":"10/4/2019","CONC":".417","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"Sample Transmitted Late","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-10-04"},{"SOURCE_ROW_NUMBER":"2720437","SMP_TAKEN_DT":"10/4/2019","CONC":".342","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"Sample Transmitted Late","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-10-04"},{"SOURCE_ROW_NUMBER":"2379453","SMP_TAKEN_DT":"10/4/2019","CONC":".767","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"Sample Transmitted Late","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-10-04"},{"SOURCE_ROW_NUMBER":"1868324","SMP_TAKEN_DT":"10/4/2019","CONC":".647","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"Sample Transmitted Late","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-10-04"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":44,"firstDate":"2015-04-24","lastDate":"2019-09-30","metrics":{"linkedIssuances":44},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":609,"firstDate":"2009-09-21","lastDate":"2020-03-30","metrics":{"decisions":609,"ssChanged":129,"recentRows":0,"decisionPenalty":670341.5,"proposedPenalty":907662},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"332501","CITATION_NO":"9222082","CITATION_ISSUE_DT":"03/30/2020","DOCKET_NO":"WEVA 2020-0427","DECISION_DT":"12/11/2020","CFR_STANDARD_CODE":"75.1713-2(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"3046.00","DECISION_PENALTY_AMT":"616.00","sourceDate":"2020-03-30"},{"SOURCE_ROW_NUMBER":"274021","CITATION_NO":"9226266","CITATION_ISSUE_DT":"10/01/2019","DOCKET_NO":"WEVA 2020-0142","DECISION_DT":"03/10/2020","CFR_STANDARD_CODE":"75.1714-3(e)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"121.00","sourceDate":"2019-10-01"},{"SOURCE_ROW_NUMBER":"270908","CITATION_NO":"9226267","CITATION_ISSUE_DT":"10/01/2019","DOCKET_NO":"WEVA 2020-0142","DECISION_DT":"03/10/2020","CFR_STANDARD_CODE":"75.1714-4(c)(2)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1242.00","DECISION_PENALTY_AMT":"1242.00","sourceDate":"2019-10-01"},{"SOURCE_ROW_NUMBER":"48108","CITATION_NO":"9226265","CITATION_ISSUE_DT":"10/01/2019","DOCKET_NO":"WEVA 2020-0142","DECISION_DT":"03/10/2020","CFR_STANDARD_CODE":"75.1714-3(d)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1242.00","DECISION_PENALTY_AMT":"1242.00","sourceDate":"2019-10-01"},{"SOURCE_ROW_NUMBER":"384327","CITATION_NO":"9223964","CITATION_ISSUE_DT":"09/30/2019","DOCKET_NO":"WEVA 2020-0142","DECISION_DT":"03/10/2020","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"902.00","DECISION_PENALTY_AMT":"902.00","sourceDate":"2019-09-30"},{"SOURCE_ROW_NUMBER":"387057","CITATION_NO":"9226766","CITATION_ISSUE_DT":"09/26/2019","DOCKET_NO":"WEVA 2020-0142","DECISION_DT":"03/10/2020","CFR_STANDARD_CODE":"75.342(a)(4)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"121.00","sourceDate":"2019-09-26"},{"SOURCE_ROW_NUMBER":"330822","CITATION_NO":"9226765","CITATION_ISSUE_DT":"09/24/2019","DOCKET_NO":"WEVA 2020-0142","DECISION_DT":"03/10/2020","CFR_STANDARD_CODE":"75.503","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"154.00","DECISION_PENALTY_AMT":"154.00","sourceDate":"2019-09-24"},{"SOURCE_ROW_NUMBER":"106743","CITATION_NO":"9226764","CITATION_ISSUE_DT":"09/24/2019","DOCKET_NO":"WEVA 2020-0142","DECISION_DT":"03/10/2020","CFR_STANDARD_CODE":"75.342(a)(4)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"121.00","sourceDate":"2019-09-24"},{"SOURCE_ROW_NUMBER":"444526","CITATION_NO":"9226763","CITATION_ISSUE_DT":"09/23/2019","DOCKET_NO":"WEVA 2020-0142","DECISION_DT":"03/10/2020","CFR_STANDARD_CODE":"75.517","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"8468.00","DECISION_PENALTY_AMT":"3468.00","sourceDate":"2019-09-23"},{"SOURCE_ROW_NUMBER":"439762","CITATION_NO":"9226762","CITATION_ISSUE_DT":"09/23/2019","DOCKET_NO":"WEVA 2020-0142","DECISION_DT":"03/10/2020","CFR_STANDARD_CODE":"75.517","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"8468.00","DECISION_PENALTY_AMT":"3468.00","sourceDate":"2019-09-23"},{"SOURCE_ROW_NUMBER":"328312","CITATION_NO":"9226761","CITATION_ISSUE_DT":"09/23/2019","DOCKET_NO":"WEVA 2020-0142","DECISION_DT":"03/10/2020","CFR_STANDARD_CODE":"75.503","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"154.00","DECISION_PENALTY_AMT":"154.00","sourceDate":"2019-09-23"},{"SOURCE_ROW_NUMBER":"439761","CITATION_NO":"9226759","CITATION_ISSUE_DT":"09/19/2019","DOCKET_NO":"WEVA 2020-0142","DECISION_DT":"03/10/2020","CFR_STANDARD_CODE":"75.1731(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"121.00","sourceDate":"2019-09-19"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":481,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":6,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":100,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":6,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":5,"firstDate":"2008-07-15","lastDate":"2023-09-25","metrics":{"recentRows":1,"currentOperatorTenures":1,"completedOperatorTenures":4},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":88,"firstDate":"2008-09-10","lastDate":"2023-09-06","metrics":{"inspectors":282,"recentRows":1,"onSiteHours":5637.25,"inspectionHours":9451.25,"inspectionSamples":974},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1147743","EVENT_NO":"7048081","INSPECTION_BEGIN_DT":"09/06/2023","INSPECTION_END_DT":"09/07/2023","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.25","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2023-09-06"},{"SOURCE_ROW_NUMBER":"391501","EVENT_NO":"7004697","INSPECTION_BEGIN_DT":"10/16/2020","INSPECTION_END_DT":"10/16/2020","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2020-10-16"},{"SOURCE_ROW_NUMBER":"1151499","EVENT_NO":"7015195","INSPECTION_BEGIN_DT":"03/30/2020","INSPECTION_END_DT":"04/02/2020","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12.5","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2020-03-30"},{"SOURCE_ROW_NUMBER":"787094","EVENT_NO":"7015182","INSPECTION_BEGIN_DT":"01/07/2020","INSPECTION_END_DT":"01/13/2020","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2020-01-07"},{"SOURCE_ROW_NUMBER":"26897","EVENT_NO":"7009508","INSPECTION_BEGIN_DT":"10/01/2019","INSPECTION_END_DT":"12/12/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"55.75","SUM_TOTAL_ON_SITE_HOURS":"41.25","sourceDate":"2019-10-01"},{"SOURCE_ROW_NUMBER":"342401","EVENT_NO":"7009247","INSPECTION_BEGIN_DT":"09/30/2019","INSPECTION_END_DT":"09/30/2019","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2019-09-30"},{"SOURCE_ROW_NUMBER":"392075","EVENT_NO":"7008828","INSPECTION_BEGIN_DT":"08/30/2019","INSPECTION_END_DT":"08/30/2019","ACTIVITY_CODE":"E22","ACTIVITY":"Health Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.5","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2019-08-30"},{"SOURCE_ROW_NUMBER":"364067","EVENT_NO":"7003088","INSPECTION_BEGIN_DT":"07/01/2019","INSPECTION_END_DT":"09/30/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"14","SUM_TOTAL_INSP_HOURS":"467","SUM_TOTAL_ON_SITE_HOURS":"319","sourceDate":"2019-07-01"},{"SOURCE_ROW_NUMBER":"1080535","EVENT_NO":"7003087","INSPECTION_BEGIN_DT":"06/28/2019","INSPECTION_END_DT":"07/01/2019","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13.5","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2019-06-28"},{"SOURCE_ROW_NUMBER":"127795","EVENT_NO":"7004669","INSPECTION_BEGIN_DT":"04/05/2019","INSPECTION_END_DT":"06/27/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"15","SUM_TOTAL_INSP_HOURS":"541.75","SUM_TOTAL_ON_SITE_HOURS":"318.75","sourceDate":"2019-04-05"},{"SOURCE_ROW_NUMBER":"408554","EVENT_NO":"6306044","INSPECTION_BEGIN_DT":"03/29/2019","INSPECTION_END_DT":"03/30/2019","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13.5","SUM_TOTAL_ON_SITE_HOURS":"12.5","sourceDate":"2019-03-29"},{"SOURCE_ROW_NUMBER":"418995","EVENT_NO":"6306042","INSPECTION_BEGIN_DT":"03/18/2019","INSPECTION_END_DT":"03/20/2019","ACTIVITY_CODE":"E22","ACTIVITY":"Health Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"25","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2019-03-18"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":58,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2023-Q4":{"hours":0,"employees":0,"production":0},"2021-Q4":{"hours":0,"employees":0,"production":0},"2021-Q3":{"hours":0,"employees":0,"production":0},"2021-Q2":{"hours":0,"employees":0,"production":0},"2021-Q1":{"hours":450,"employees":1,"production":0},"2020-Q4":{"hours":635,"employees":1,"production":0},"2020-Q3":{"hours":756,"employees":1,"production":0},"2020-Q2":{"hours":746,"employees":1,"production":0},"2020-Q1":{"hours":1649,"employees":3,"production":0},"2019-Q4":{"hours":38502,"employees":69,"production":6399},"2019-Q3":{"hours":77290,"employees":124,"production":83944},"2019-Q2":{"hours":84958,"employees":114,"production":75696}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":14,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2008":{"hours":60,"employees":1,"production":0},"2009":{"hours":90,"employees":1,"production":0},"2015":{"hours":98546,"employees":71,"production":260817},"2016":{"hours":269708,"employees":128,"production":578947},"2017":{"hours":295111,"employees":136,"production":553660},"2018":{"hours":280022,"employees":113,"production":461204},"2019":{"hours":277844,"employees":104,"production":259627},"2020":{"hours":3786,"employees":2,"production":0},"2021":{"hours":450,"employees":1,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":145,"firstDate":"2015-05-18","lastDate":"2019-04-10","metrics":{"recentRows":0,"doseOver100":28,"actDoseTotal":10194,"pelDoseTotal":7604},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"263694","EVENT_NO":"7004669","SURVEY_DATE":"04/10/2019","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"84","PEL_DOSE_90":"70","SURVEY_TYPE":"F","sourceDate":"2019-04-10"},{"SOURCE_ROW_NUMBER":"263693","EVENT_NO":"7004669","SURVEY_DATE":"04/10/2019","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"99","PEL_DOSE_90":"88","SURVEY_TYPE":"F","sourceDate":"2019-04-10"},{"SOURCE_ROW_NUMBER":"263692","EVENT_NO":"7004669","SURVEY_DATE":"04/10/2019","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"83","PEL_DOSE_90":"69","SURVEY_TYPE":"F","sourceDate":"2019-04-10"},{"SOURCE_ROW_NUMBER":"263607","EVENT_NO":"6306042","SURVEY_DATE":"03/19/2019","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"253","PEL_DOSE_90":"240","SURVEY_TYPE":"I","sourceDate":"2019-03-19"},{"SOURCE_ROW_NUMBER":"263606","EVENT_NO":"6306042","SURVEY_DATE":"03/19/2019","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"231","PEL_DOSE_90":"213","SURVEY_TYPE":"I","sourceDate":"2019-03-19"},{"SOURCE_ROW_NUMBER":"263605","EVENT_NO":"6306042","SURVEY_DATE":"03/19/2019","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"72","PEL_DOSE_90":"57","SURVEY_TYPE":"I","sourceDate":"2019-03-19"},{"SOURCE_ROW_NUMBER":"263604","EVENT_NO":"6306042","SURVEY_DATE":"03/19/2019","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"105","PEL_DOSE_90":"85","SURVEY_TYPE":"I","sourceDate":"2019-03-19"},{"SOURCE_ROW_NUMBER":"263603","EVENT_NO":"6306042","SURVEY_DATE":"03/19/2019","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"74","PEL_DOSE_90":"56","SURVEY_TYPE":"I","sourceDate":"2019-03-19"},{"SOURCE_ROW_NUMBER":"263602","EVENT_NO":"6306042","SURVEY_DATE":"03/19/2019","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"70","PEL_DOSE_90":"53","SURVEY_TYPE":"I","sourceDate":"2019-03-19"},{"SOURCE_ROW_NUMBER":"263601","EVENT_NO":"6306042","SURVEY_DATE":"03/19/2019","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"105","PEL_DOSE_90":"87","SURVEY_TYPE":"I","sourceDate":"2019-03-19"},{"SOURCE_ROW_NUMBER":"263600","EVENT_NO":"6306042","SURVEY_DATE":"03/19/2019","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"72","PEL_DOSE_90":"53","SURVEY_TYPE":"I","sourceDate":"2019-03-19"},{"SOURCE_ROW_NUMBER":"263599","EVENT_NO":"6306042","SURVEY_DATE":"03/19/2019","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"176","PEL_DOSE_90":"156","SURVEY_TYPE":"I","sourceDate":"2019-03-19"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":168,"firstDate":"2015-05-04","lastDate":"2019-09-04","metrics":{"recentRows":0,"voidSamples":28,"maxQuartzPct":34.6,"validSamples":140,"quartzPctTotal":1560.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"155035","CASSETTE_NO":"58352183","SAMPLE_DT":"09/04/2019","QUARTZ_PCT":"05.5","QUARTZ_MICROGRAMS":"15","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-09-04"},{"SOURCE_ROW_NUMBER":"147321","CASSETTE_NO":"58352544","SAMPLE_DT":"09/04/2019","QUARTZ_PCT":"03.8","QUARTZ_MICROGRAMS":"9","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-09-04"},{"SOURCE_ROW_NUMBER":"115706","CASSETTE_NO":"58352548","SAMPLE_DT":"09/04/2019","QUARTZ_PCT":"07.7","QUARTZ_MICROGRAMS":"39","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-09-04"},{"SOURCE_ROW_NUMBER":"91554","CASSETTE_NO":"58352542","SAMPLE_DT":"09/04/2019","QUARTZ_PCT":"05.2","QUARTZ_MICROGRAMS":"20","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-09-04"},{"SOURCE_ROW_NUMBER":"57897","CASSETTE_NO":"58352395","SAMPLE_DT":"09/04/2019","QUARTZ_PCT":"05.7","QUARTZ_MICROGRAMS":"33","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-09-04"},{"SOURCE_ROW_NUMBER":"54013","CASSETTE_NO":"58352171","SAMPLE_DT":"09/04/2019","QUARTZ_PCT":"09.3","QUARTZ_MICROGRAMS":"29","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-09-04"},{"SOURCE_ROW_NUMBER":"139858","CASSETTE_NO":"58352378","SAMPLE_DT":"09/03/2019","QUARTZ_PCT":"06.7","QUARTZ_MICROGRAMS":"66","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-09-03"},{"SOURCE_ROW_NUMBER":"124957","CASSETTE_NO":"58352264","SAMPLE_DT":"09/03/2019","QUARTZ_PCT":"08.0","QUARTZ_MICROGRAMS":"47","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-09-03"},{"SOURCE_ROW_NUMBER":"98608","CASSETTE_NO":"58352587","SAMPLE_DT":"09/03/2019","QUARTZ_PCT":"09.3","QUARTZ_MICROGRAMS":"15","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-09-03"},{"SOURCE_ROW_NUMBER":"69842","CASSETTE_NO":"58352343","SAMPLE_DT":"09/03/2019","QUARTZ_PCT":"06.6","QUARTZ_MICROGRAMS":"17","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-09-03"},{"SOURCE_ROW_NUMBER":"55859","CASSETTE_NO":"58352374","SAMPLE_DT":"09/03/2019","QUARTZ_PCT":"07.3","QUARTZ_MICROGRAMS":"15","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-09-03"},{"SOURCE_ROW_NUMBER":"36187","CASSETTE_NO":"58352554","SAMPLE_DT":"09/03/2019","QUARTZ_PCT":"11.9","QUARTZ_MICROGRAMS":"22","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-09-03"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":1128,"firstDate":"2008-09-17","lastDate":"2020-03-30","metrics":{"ss":268,"amountDue":754848.5,"contested":1,"amountPaid":740812.35,"recentRows":0,"section104d":6,"unterminated":1,"proposedPenalty":992169},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2946379","VIOLATION_NO":"9222082","VIOLATION_ISSUE_DT":"03/30/2020","SIG_SUB":"N","PART_SECTION":"75.1713-2(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"03/31/2020","PROPOSED_PENALTY":"3046","AMOUNT_DUE":"616","AMOUNT_PAID":"616","CONTESTED_IND":"N","sourceDate":"2020-03-30"},{"SOURCE_ROW_NUMBER":"2946364","VIOLATION_NO":"9222080","VIOLATION_ISSUE_DT":"01/08/2020","SIG_SUB":"N","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/13/2020","PROPOSED_PENALTY":"234","AMOUNT_DUE":"234","AMOUNT_PAID":"234","CONTESTED_IND":"N","sourceDate":"2020-01-08"},{"SOURCE_ROW_NUMBER":"2947110","VIOLATION_NO":"9229024","VIOLATION_ISSUE_DT":"12/10/2019","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"12/12/2019","PROPOSED_PENALTY":"168","AMOUNT_DUE":"168","AMOUNT_PAID":"168","CONTESTED_IND":"N","sourceDate":"2019-12-10"},{"SOURCE_ROW_NUMBER":"2947109","VIOLATION_NO":"9229023","VIOLATION_ISSUE_DT":"12/10/2019","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/12/2019","PROPOSED_PENALTY":"514","AMOUNT_DUE":"514","AMOUNT_PAID":"514","CONTESTED_IND":"N","sourceDate":"2019-12-10"},{"SOURCE_ROW_NUMBER":"2947108","VIOLATION_NO":"9229022","VIOLATION_ISSUE_DT":"12/10/2019","SIG_SUB":"N","PART_SECTION":"75.518","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"12/10/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-12-10"},{"SOURCE_ROW_NUMBER":"2947107","VIOLATION_NO":"9229021","VIOLATION_ISSUE_DT":"12/10/2019","SIG_SUB":"N","PART_SECTION":"75.518","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"12/10/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-12-10"},{"SOURCE_ROW_NUMBER":"2947106","VIOLATION_NO":"9229020","VIOLATION_ISSUE_DT":"12/10/2019","SIG_SUB":"N","PART_SECTION":"75.516","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/10/2019","PROPOSED_PENALTY":"250","AMOUNT_DUE":"250","AMOUNT_PAID":"250","CONTESTED_IND":"N","sourceDate":"2019-12-10"},{"SOURCE_ROW_NUMBER":"2947105","VIOLATION_NO":"9226274","VIOLATION_ISSUE_DT":"10/07/2019","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/07/2019","PROPOSED_PENALTY":"319","AMOUNT_DUE":"319","AMOUNT_PAID":"319","CONTESTED_IND":"N","sourceDate":"2019-10-07"},{"SOURCE_ROW_NUMBER":"2947104","VIOLATION_NO":"9226273","VIOLATION_ISSUE_DT":"10/06/2019","SIG_SUB":"N","PART_SECTION":"75.312(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/07/2019","PROPOSED_PENALTY":"214","AMOUNT_DUE":"214","AMOUNT_PAID":"214","CONTESTED_IND":"N","sourceDate":"2019-10-06"},{"SOURCE_ROW_NUMBER":"2947103","VIOLATION_NO":"9226272","VIOLATION_ISSUE_DT":"10/06/2019","SIG_SUB":"N","PART_SECTION":"75.360(g)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/06/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-10-06"},{"SOURCE_ROW_NUMBER":"2947102","VIOLATION_NO":"9226267","VIOLATION_ISSUE_DT":"10/01/2019","SIG_SUB":"N","PART_SECTION":"75.1714-4(c)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"13","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/03/2019","PROPOSED_PENALTY":"1242","AMOUNT_DUE":"1242","AMOUNT_PAID":"1242","CONTESTED_IND":"N","sourceDate":"2019-10-01"},{"SOURCE_ROW_NUMBER":"2947101","VIOLATION_NO":"9226266","VIOLATION_ISSUE_DT":"10/01/2019","SIG_SUB":"N","PART_SECTION":"75.1714-3(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/03/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-10-01"}]}],"safety":{"href":"/api/v1/mines/4609294/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609294/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Emergency communications; requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1713-2","part":"75","subchapter":"O","subpart":"R","id":"75.1713-2","citation":"30 CFR 75.1713-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","heading":"Electric equipment and circuits; overload and short circuit protection.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.518","part":"75","subchapter":"O","subpart":"F","id":"75.518","citation":"30 CFR 75.518","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.516","heading":"Power wires; support.","id":"75.516","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.516","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll power wires (except trailing cables on mobile equipment, specially designed cables conducting high-voltage power to underground rectifying equipment or transformers, or bare or insulated ground and return wires) shall be supported on well-insulated insulators and shall not contact combustible material, roof, or ribs.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","heading":"Main mine fan examinations and records.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.312","part":"75","subchapter":"O","subpart":"D","id":"75.312","citation":"30 CFR 75.312","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.360","heading":"Preshift examination at fixed intervals.","id":"75.360","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.360","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) Except as provided in paragraph (a)(2) of this section, a certified person designated by the operator must make a preshift examination within 3 hours preceding the beginning of any 8-hour interval during which any person is scheduled to work or travel underground. No person other than certified examiners may enter or remain in any underground area unless a preshift examination has been completed for the established 8-hour interval. The operator must establish 8-hour intervals of time subject to the required preshift examinations.\n\n(2) Preshift examinations of areas where pumpers are scheduled to work or travel shall not be required prior to the pumper entering the areas if the pumper is a certified person and the pumper conducts an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, tests for methane and oxygen deficiency, and determines if the air is moving in its proper direction in the area where the pumper works or travels. The examination of the area must be completed before the pumper performs any other work. A record of all hazardous conditions and violations of the mandatory health or safety standards found by the pumper shall be made and retained in accordance with § 75.363 of this part.\n\n(b) The person conducting the preshift examination shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction at the following locations:\n\n(1) Roadways, travelways and track haulageways where persons are scheduled, prior to the beginning of the preshift examination, to work or travel during the oncoming shift.\n\n(2) Belt conveyors that will be used to transport persons during the oncoming shift and the entries in which these belt conveyors are located.\n\n(3) Working sections and areas where mechanized mining equipment is being installed or removed, if anyone is scheduled to work on the section or in the area during the oncoming shift. The scope of the examination shall include the working places, approaches to worked-out areas and ventilation controls on these sections and in these areas, and the examination shall include tests of the roof, face and rib conditions on these sections and in these areas.\n\n(4) Approaches to worked-out areas along intake air courses and at the entries used to carry air into worked-out areas if the intake air passing the approaches is used to ventilate working sections where anyone is scheduled to work during the oncoming shift. The examination of the approaches to the worked-out areas shall be made in the intake air course immediately inby and outby each entry used to carry air into the worked-out area. An examination of the entries used to carry air into the worked-out areas shall be conducted at a point immediately inby the intersection of each entry with the intake air course.\n\n(5) Seals along intake air courses where intake air passes by a seal to ventilate working sections where anyone is scheduled to work during the oncoming shift.\n\n(6)(i) Entries and rooms developed after November 15, 1992, and developed more than 2 crosscuts off an intake air course without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift; and,\n\n(ii) Entries and rooms developed after November 15, 1992, and driven more than 20 feet off an intake air course without a crosscut and without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift.\n\n(7) Areas where trolley wires or trolley feeder wires are to be or will remain energized during the oncoming shift.\n\n(8) High spots along intake air courses where methane is likely to accumulate, if equipment will be operated in the area during the shift.\n\n(9) Underground electrical installations referred to in § 75.340(a), except those pumps listed in § 75.340 (b)(2) through (b)(6), and areas where compressors subject to § 75.344 are installed if the electrical installation or compressor is or will be energized during the shift.\n\n(10) Other areas where work or travel during the oncoming shift is scheduled prior to the beginning of the preshift examination.\n\n(11) Preshift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) The person conducting the preshift examination shall determine the volume of air entering each of the following areas if anyone is scheduled to work in the areas during the oncoming shift:\n\n(1) In the last open crosscut of each set of entries or rooms on each working section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) On each longwall or shortwall in the intake entry or entries at the intake end of the longwall or shortwall face immediately outby the face and the velocity of air at each end of the face at the locations specified in the approved ventilation plan.\n\n(3) At the intake end of any pillar line—\n\n(i) If a single split of air is used, in the intake entry furthest from the return air course, immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) If a split system is used, in the intake entries of each split immediately inby the split point.\n\n(d) The person conducting the preshift examination shall check the refuge alternative for damage, the integrity of the tamper-evident seal and the mechanisms required to deploy the refuge alternative, and the ready availability of compressed oxygen and air.\n\n(e) The district manager may require the operator to examine other areas of the mine or examine for other hazards and violations of other mandatory health or safety standards found during the preshift examination.\n\n(f) Certification. At each working place examined, the person doing the preshift examination shall certify by initials, date, and the time, that the examination was made. In areas required to be examined outby a working section, the certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(g) Recordkeeping. A record of the results of each preshift examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards and their locations found by the examiner during each examination, and of the results and locations of air and methane measurements, shall be made on the surface before any persons, other than certified persons conducting examinations required by this subpart, enter any underground area of the mine. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the certified person who made the examination or by a person designated by the operator. If the record is made by someone other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. A record shall also be made by a certified person of the action taken to correct hazardous conditions and violations of mandatory health or safety standards found during the preshift examination. All preshift and corrective action records shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(h) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 62 FR 35085, June 30, 1997; 64 FR 45170, Aug. 19, 1999; 73 FR 80697, Dec. 31, 2008; 77 FR 20714, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1714-4","heading":"Additional self-contained self-rescuers (SCSRs).","id":"75.1714-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Additional SCSRs in work places. In addition to the requirements in §§ 75.1714, 75.1714-1, 75.1714-2, and 75.1714-3 of this part, the mine operator shall provide the following:\n\n(1) At least one additional SCSR, which provides protection for a period of one hour or longer, for each person at a fixed underground work location.\n\n(2) Additional SCSRs along the normal travel routes for pumpers, examiners, and other persons who do not have a fixed work location to be stored at a distance an average miner could walk in 30 minutes. The SCSR storage locations shall be determined by using one of the methods found under paragraph (c)(2) of this section.\n\n(b) Additional SCSRs on mantrips. If a mantrip or mobile equipment is used to enter or exit the mine, at least one additional SCSR, which provides protection for a period of one hour or longer, shall be available for each person who uses such transportation from portal to portal.\n\n(c) Additional SCSRs in escapeways. When each person underground cannot safely evacuate the mine within 30 minutes, the mine operator shall provide additional SCSRs stored in each required escapeway.\n\n(1) Each storage location shall contain at least one SCSR, which provides protection for a period of one hour or longer, for every person who will be inby that location.\n\n(2) Storage locations shall be spaced along each escapeway at 30-minute travel distances no greater than the distances determined by—\n\n(i) Calculating the distance an average miner walks in 30 minutes by using the time necessary for each miner in a sample of typical miners to walk a typical length of each escapeway; or\n\n(ii) Using the SCSR storage location spacing specified in the following table, except for escapeways with grades over 5 percent.\n\nAverage entry height Maximum distancebetween SCSR storage locations (in ft.) <40 in. (Crawl) 2,200 >40-<50 in. (Duck Walk) 3,300 >50-<65 in. (Walk Head Bent) 4,400 >65 in. (Walk Erect) 5,700\n\n(d) Additional SCSRs in hardened rooms. As an alternative to providing SCSR storage locations in each escapeway, the mine operator may store SCSRs in a hardened room located between adjacent escapeways.\n\n(1) The hardened room shall be designed and constructed to the same explosion force criteria as seals.\n\n(2) The hardened room shall include a means to provide independent, positive pressure ventilation from the surface during an emergency.\n\n(3) The District Manager shall approve the design and construction of hardened rooms in the ventilation plan.\n\n(4) These SCSR storage locations shall be spaced in accordance with paragraph (c) of this section.\n\n(e) Storage location accessibility. All SCSRs required under this section shall be stored according to the manufacturers' instructions, in conspicuous locations readily accessible by each person in the mine.\n\n(f) Storage location signs. A sign made of reflective material with the words “SCSRs” or “SELF-RESCUERS” shall be conspicuously posted at each storage location. Direction signs made of a reflective material shall be posted leading to each storage location.\n\n[71 FR 71454, Dec. 8, 2006]","occurrenceCount":1},{"chapter":"I","heading":"Self-rescue devices; inspection, testing, maintenance, repair, and recordkeeping.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-3","part":"75","subchapter":"O","subpart":"R","id":"75.1714-3","citation":"30 CFR 75.1714-3","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609294","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}