{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4609230","name":"Winchester UG Mine","status":"Abandoned","status_date":"2020-05-15","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Kanawha","nearest_town":"Leewood","operator_id":"0141673","operator_name":"Panther Creek Mining LLC","controller_id":"0158381","controller_name":"Sev.en Global Investments a.s.","district":"C04","office":"Madison WV Field Office","employees":0,"latitude":38.058333,"longitude":-81.464444},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":18165},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609230","name":"Winchester UG Mine"},"operator":{"type":"operator","id":"0141673","name":"Panther Creek Mining LLC"},"controller":{"type":"controller","id":"0158381","name":"Sev.en Global Investments a.s."},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"0056849","name":"Magnum Coal Company"},"object":{"type":"mine","id":"4609230","name":"Winchester UG Mine"},"validFrom":"2003-07-03","validTo":"2008-07-22","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609230|0056849|2003-07-03|2008-07-22"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0051510","name":"Remington LLC"},"object":{"type":"mine","id":"4609230","name":"Winchester UG Mine"},"validFrom":"2007-09-13","validTo":"2015-10-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609230|0051510|2007-09-13|2015-10-25"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0056849","name":"Magnum Coal Company"},"object":{"type":"operator","id":"0051510","name":"Remington LLC"},"validFrom":"2007-09-13","validTo":"2008-07-22","current":false,"derived":true,"evidenceMineId":"4609230","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609230|0051510|2007-09-13|0056849|2003-07-03|7462"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0071611","name":"Patriot Coal Corporation"},"object":{"type":"mine","id":"4609230","name":"Winchester UG Mine"},"validFrom":"2008-07-23","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609230|0071611|2008-07-23|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0071611","name":"Patriot Coal Corporation"},"object":{"type":"operator","id":"0051510","name":"Remington LLC"},"validFrom":"2008-07-23","validTo":"2015-10-25","current":false,"derived":true,"evidenceMineId":"4609230","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609230|0051510|2007-09-13|0071611|2008-07-23|10406"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0141673","name":"Panther Creek Mining LLC"},"object":{"type":"mine","id":"4609230","name":"Winchester UG Mine"},"validFrom":"2015-10-26","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609230|0141673|2015-10-26|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0109461","name":"Blackhawk Mining LLC"},"object":{"type":"mine","id":"4609230","name":"Winchester UG Mine"},"validFrom":"2015-10-26","validTo":"2020-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609230|0109461|2015-10-26|2020-05-31"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0109461","name":"Blackhawk Mining LLC"},"object":{"type":"operator","id":"0141673","name":"Panther Creek Mining LLC"},"validFrom":"2015-10-26","validTo":"2020-05-31","current":false,"derived":true,"evidenceMineId":"4609230","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609230|0141673|2015-10-26|0109461|2015-10-26|19931"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0158381","name":"Sev.en Global Investments a.s."},"object":{"type":"mine","id":"4609230","name":"Winchester UG Mine"},"validFrom":"2020-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609230|0158381|2020-06-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0158381","name":"Sev.en Global Investments a.s."},"object":{"type":"operator","id":"0141673","name":"Panther Creek Mining LLC"},"validFrom":"2020-06-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609230","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609230|0141673|2015-10-26|0158381|2020-06-01|32869"}}],"coverage":{"historyRecords":4,"edgeCount":10,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":125,"firstDate":"2008-06-20","lastDate":"2019-06-15","metrics":{"daysLost":4012,"injuries":115,"fatalities":0,"recentRows":0,"restrictedDays":494,"contractorRecords":3},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"111348","DOCUMENT_NO":"220191710016","ACCIDENT_DT":"06/15/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALLING/SLIDING/ROLLING MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Miner, NEC","NO_INJURIES":"1","DAYS_LOST":"49","NARRATIVE":"Employee states that they were struck in the leg and foot by an 8 inch I beam that came loose for a belt take-up that was being removed as part of a section move. Employee suffered a fractured ankle and fractured metatarsal bones.","sourceDate":"2019-06-15"},{"SOURCE_ROW_NUMBER":"253552","DOCUMENT_NO":"220191710045","ACCIDENT_DT":"06/11/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Scoop tram operator, Load/Haul/Dump operator","NO_INJURIES":"1","DAYS_LOST":"14","NARRATIVE":"Employee states that EE received an injury to EE's hand while raising the lid on  the scoop batteries. Employee states that the support rod for the battery lid did not latch causing the lid to strike EE's hand.","sourceDate":"2019-06-11"},{"SOURCE_ROW_NUMBER":"106950","DOCUMENT_NO":"220190980035","ACCIDENT_DT":"03/23/2019","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee stated was operating the Joy 14/15 C/M machine on the Unit 1 Section. In the process of operating the machine cleaning up some gob a rock flew off of the C/M head and struck the employee in the mouth. This caused EE's tooth to be chipped. NOTE: This employee didn't seek medical treatment until 4/8/2019 and that is why it is now being reported.","sourceDate":"2019-03-23"},{"SOURCE_ROW_NUMBER":"210498","DOCUMENT_NO":"220183040038","ACCIDENT_DT":"10/29/2018","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was struck on the right knee by a piece of belt structure.","sourceDate":"2018-10-29"},{"SOURCE_ROW_NUMBER":"154577","DOCUMENT_NO":"220182900007","ACCIDENT_DT":"10/10/2018","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"99","NARRATIVE":"Employee was hanging miner cable when they slipped on a small piece of slate rock and fractured the outermost distal toe which resulted in lost workdays.","sourceDate":"2018-10-10"},{"SOURCE_ROW_NUMBER":"219158","DOCUMENT_NO":"220182840011","ACCIDENT_DT":"10/09/2018","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was operating a continuous miner when EE was struck by a roof bolter trailing cable that was knocked down by a rock that was coming out of the conveyor chain of the miner which resulted in a laceration that required 5 sutures. No lost or restricted work days.","sourceDate":"2018-10-09"},{"SOURCE_ROW_NUMBER":"163177","DOCUMENT_NO":"220182840010","ACCIDENT_DT":"10/05/2018","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"22","NARRATIVE":"Employee was trying to install a bottom roller when EE crawled underneath the belt to use EE's back to lift the belt which resulted in a sprain/strain injury and lost work days.","sourceDate":"2018-10-05"},{"SOURCE_ROW_NUMBER":"42687","DOCUMENT_NO":"220182690021","ACCIDENT_DT":"09/18/2018","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was removing a spreader bar from the boom of the continuous miner when a sharp piece of metal on the spreader bar cut employee's hand resulting in a laceration that required 3 sutures. No Lost or Restricted work days.","sourceDate":"2018-09-18"},{"SOURCE_ROW_NUMBER":"128516","DOCUMENT_NO":"220182600069","ACCIDENT_DT":"09/11/2018","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"256","NARRATIVE":"Injured employee was hanging continuous miner cable in the #6 entry when EE heard a pop in the right elbow which resulted in a sprain / strain type injury and lost work days.","sourceDate":"2018-09-11"},{"SOURCE_ROW_NUMBER":"154576","DOCUMENT_NO":"220182200014","ACCIDENT_DT":"07/30/2018","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was operating a roof bolter when ee tried to catch drill steel that was falling out of hole and struck left hand against the drill pot causing left pinky finger to become dislocated. This did not result in any lost or restricted days.","sourceDate":"2018-07-30"},{"SOURCE_ROW_NUMBER":"244960","DOCUMENT_NO":"220190940022","ACCIDENT_DT":"07/12/2018","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"20","NARRATIVE":"Employee stated ee was shoveling the belt line on the Byrd #1 belt at Break 0 when a piece of slate rock fell from the mine roof and struck the employee on the right forearm and left ring finger. The rock measured approximately 2.5' in length X 1.5' in width X 1' in thickness. NOTE: This employee didn't start missing work until 4/2/2019.","sourceDate":"2018-07-12"},{"SOURCE_ROW_NUMBER":"16895","DOCUMENT_NO":"220181860032","ACCIDENT_DT":"06/26/2018","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was operating a roof bolter machine when a rock fell on its edge and fell over onto EE's left foot which resulted in a contusion and restricted work days.","sourceDate":"2018-06-26"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2020-05-15","lastDate":"2020-05-15","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":2659,"firstDate":"2007-12-21","lastDate":"2020-02-26","metrics":{"ss":565,"delinquent":2541,"recentRows":0,"paidPenalty":1705941.65,"proposedPenalty":2624444,"currentAssessment":1873639.76},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1903402","VIOLATION_NO":"9246042","ISSUE_DT":"02/26/2020","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"217.00","CURRENT_ASSESSMENT_AMT":"217.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-02-26"},{"SOURCE_ROW_NUMBER":"1903401","VIOLATION_NO":"9246041","ISSUE_DT":"02/24/2020","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"144.00","CURRENT_ASSESSMENT_AMT":"144.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-02-24"},{"SOURCE_ROW_NUMBER":"1903400","VIOLATION_NO":"9246040","ISSUE_DT":"02/24/2020","CFR_STANDARD_CD":"77.1605(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"324.00","CURRENT_ASSESSMENT_AMT":"324.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-02-24"},{"SOURCE_ROW_NUMBER":"1903399","VIOLATION_NO":"9246039","ISSUE_DT":"02/20/2020","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"217.00","CURRENT_ASSESSMENT_AMT":"217.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-02-20"},{"SOURCE_ROW_NUMBER":"1903398","VIOLATION_NO":"9246038","ISSUE_DT":"02/20/2020","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"666.00","CURRENT_ASSESSMENT_AMT":"666.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-02-20"},{"SOURCE_ROW_NUMBER":"1903397","VIOLATION_NO":"9246025","ISSUE_DT":"02/20/2020","CFR_STANDARD_CD":"75.312(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"144.00","CURRENT_ASSESSMENT_AMT":"144.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-02-20"},{"SOURCE_ROW_NUMBER":"1903396","VIOLATION_NO":"9246024","ISSUE_DT":"01/21/2020","CFR_STANDARD_CD":"75.904","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"324.00","CURRENT_ASSESSMENT_AMT":"324.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-01-21"},{"SOURCE_ROW_NUMBER":"1903395","VIOLATION_NO":"9246023","ISSUE_DT":"01/13/2020","CFR_STANDARD_CD":"75.380(b)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"217.00","CURRENT_ASSESSMENT_AMT":"217.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-01-13"},{"SOURCE_ROW_NUMBER":"1903394","VIOLATION_NO":"9246022","ISSUE_DT":"01/08/2020","CFR_STANDARD_CD":"75.1403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"567.00","CURRENT_ASSESSMENT_AMT":"567.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-01-08"},{"SOURCE_ROW_NUMBER":"1903393","VIOLATION_NO":"9246021","ISSUE_DT":"01/08/2020","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"351.00","CURRENT_ASSESSMENT_AMT":"351.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-01-08"},{"SOURCE_ROW_NUMBER":"1906818","VIOLATION_NO":"9163466","ISSUE_DT":"12/09/2019","CFR_STANDARD_CD":"75.1714-8(a)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"123.00","CURRENT_ASSESSMENT_AMT":"123.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-12-09"},{"SOURCE_ROW_NUMBER":"1906735","VIOLATION_NO":"4637103","ISSUE_DT":"11/20/2019","CFR_STANDARD_CD":"75.523-3(b)(5)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"270.00","CURRENT_ASSESSMENT_AMT":"270.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-11-20"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":1207,"firstDate":"2008-10-17","lastDate":"2020-08-21","metrics":{"appeals":0,"decisions":1207,"recentRows":0,"decisionPenalty":1459954.26,"originalPenalty":2231202},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"422132","VIOLATION_NO":"9163461","DOCKET_NO":"WEVA 2020-0376","DECISION_DT":"08/21/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1738.00","DECISION_PENALTY_AMT":"898.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-08-21"},{"SOURCE_ROW_NUMBER":"421312","VIOLATION_NO":"9246042","DOCKET_NO":"WEVA 2020-0376","DECISION_DT":"08/21/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"217.00","DECISION_PENALTY_AMT":"217.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-08-21"},{"SOURCE_ROW_NUMBER":"420957","VIOLATION_NO":"9246038","DOCKET_NO":"WEVA 2020-0376","DECISION_DT":"08/21/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"666.00","DECISION_PENALTY_AMT":"666.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-08-21"},{"SOURCE_ROW_NUMBER":"420434","VIOLATION_NO":"9246039","DOCKET_NO":"WEVA 2020-0376","DECISION_DT":"08/21/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"217.00","DECISION_PENALTY_AMT":"217.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-08-21"},{"SOURCE_ROW_NUMBER":"144211","VIOLATION_NO":"9246041","DOCKET_NO":"WEVA 2020-0376","DECISION_DT":"08/21/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"144.00","DECISION_PENALTY_AMT":"144.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-08-21"},{"SOURCE_ROW_NUMBER":"144210","VIOLATION_NO":"9246040","DOCKET_NO":"WEVA 2020-0376","DECISION_DT":"08/21/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"324.00","DECISION_PENALTY_AMT":"324.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-08-21"},{"SOURCE_ROW_NUMBER":"144209","VIOLATION_NO":"9245464","DOCKET_NO":"WEVA 2020-0376","DECISION_DT":"08/21/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1263.00","DECISION_PENALTY_AMT":"1263.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-08-21"},{"SOURCE_ROW_NUMBER":"144048","VIOLATION_NO":"9246025","DOCKET_NO":"WEVA 2020-0376","DECISION_DT":"08/21/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"144.00","DECISION_PENALTY_AMT":"144.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-08-21"},{"SOURCE_ROW_NUMBER":"143941","VIOLATION_NO":"9245462","DOCKET_NO":"WEVA 2020-0376","DECISION_DT":"08/21/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1884.00","DECISION_PENALTY_AMT":"988.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-08-21"},{"SOURCE_ROW_NUMBER":"419044","VIOLATION_NO":"9163454","DOCKET_NO":"WEVA 2020-0193","DECISION_DT":"04/16/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"355.00","DECISION_PENALTY_AMT":"355.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-04-16"},{"SOURCE_ROW_NUMBER":"418211","VIOLATION_NO":"9163451","DOCKET_NO":"WEVA 2020-0193","DECISION_DT":"04/16/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"787.00","DECISION_PENALTY_AMT":"787.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-04-16"},{"SOURCE_ROW_NUMBER":"420551","VIOLATION_NO":"9163459","DOCKET_NO":"WEVA 2020-0244","DECISION_DT":"04/15/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"405.00","DECISION_PENALTY_AMT":"405.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-04-15"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":8032,"firstDate":"2000-04-11","lastDate":"2020-01-07","metrics":{"recentRows":0,"cpdmSamples":5071,"voidSamples":2652,"validSamples":5380,"maxConcentration":32.293,"concentrationTotal":4194.336},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2721448","SMP_TAKEN_DT":"1/7/2020","CONC":".323","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-01-07"},{"SOURCE_ROW_NUMBER":"2295137","SMP_TAKEN_DT":"1/7/2020","CONC":".131","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-01-07"},{"SOURCE_ROW_NUMBER":"2039621","SMP_TAKEN_DT":"1/7/2020","CONC":".538","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-01-07"},{"SOURCE_ROW_NUMBER":"1784947","SMP_TAKEN_DT":"1/7/2020","CONC":".487","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-01-07"},{"SOURCE_ROW_NUMBER":"2806644","SMP_TAKEN_DT":"1/6/2020","CONC":".52","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-01-06"},{"SOURCE_ROW_NUMBER":"1784027","SMP_TAKEN_DT":"1/6/2020","CONC":".476","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-01-06"},{"SOURCE_ROW_NUMBER":"2550949","SMP_TAKEN_DT":"12/31/2019","CONC":".598","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-12-31"},{"SOURCE_ROW_NUMBER":"2038899","SMP_TAKEN_DT":"12/30/2019","CONC":".285","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-12-30"},{"SOURCE_ROW_NUMBER":"1386081","CASS_NUM":"58405176","SMP_TAKEN_DT":"12/30/2019","CONC":".22","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2019-12-30"},{"SOURCE_ROW_NUMBER":"1267038","CASS_NUM":"58405091","SMP_TAKEN_DT":"12/30/2019","CONC":".178","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2019-12-30"},{"SOURCE_ROW_NUMBER":"717815","CASS_NUM":"58405173","SMP_TAKEN_DT":"12/30/2019","CONC":".382","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2019-12-30"},{"SOURCE_ROW_NUMBER":"590973","CASS_NUM":"58405154","SMP_TAKEN_DT":"12/30/2019","CONC":".2","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2019-12-30"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":149,"firstDate":"2011-11-10","lastDate":"2020-03-24","metrics":{"linkedIssuances":149},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":1207,"firstDate":"2007-12-21","lastDate":"2020-02-26","metrics":{"decisions":1207,"ssChanged":121,"recentRows":0,"decisionPenalty":1459954.26,"proposedPenalty":2231202},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"383064","CITATION_NO":"9246042","CITATION_ISSUE_DT":"02/26/2020","DOCKET_NO":"WEVA 2020-0376","DECISION_DT":"08/21/2020","CFR_STANDARD_CODE":"75.503","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"217.00","DECISION_PENALTY_AMT":"217.00","sourceDate":"2020-02-26"},{"SOURCE_ROW_NUMBER":"444818","CITATION_NO":"9246041","CITATION_ISSUE_DT":"02/24/2020","DOCKET_NO":"WEVA 2020-0376","DECISION_DT":"08/21/2020","CFR_STANDARD_CODE":"75.503","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"144.00","DECISION_PENALTY_AMT":"144.00","sourceDate":"2020-02-24"},{"SOURCE_ROW_NUMBER":"386337","CITATION_NO":"9246040","CITATION_ISSUE_DT":"02/24/2020","DOCKET_NO":"WEVA 2020-0376","DECISION_DT":"08/21/2020","CFR_STANDARD_CODE":"77.1605(b)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"324.00","DECISION_PENALTY_AMT":"324.00","sourceDate":"2020-02-24"},{"SOURCE_ROW_NUMBER":"386112","CITATION_NO":"9246025","CITATION_ISSUE_DT":"02/20/2020","DOCKET_NO":"WEVA 2020-0376","DECISION_DT":"08/21/2020","CFR_STANDARD_CODE":"75.312(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"144.00","DECISION_PENALTY_AMT":"144.00","sourceDate":"2020-02-20"},{"SOURCE_ROW_NUMBER":"214131","CITATION_NO":"9246039","CITATION_ISSUE_DT":"02/20/2020","DOCKET_NO":"WEVA 2020-0376","DECISION_DT":"08/21/2020","CFR_STANDARD_CODE":"75.503","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"217.00","DECISION_PENALTY_AMT":"217.00","sourceDate":"2020-02-20"},{"SOURCE_ROW_NUMBER":"161256","CITATION_NO":"9246038","CITATION_ISSUE_DT":"02/20/2020","DOCKET_NO":"WEVA 2020-0376","DECISION_DT":"08/21/2020","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"666.00","DECISION_PENALTY_AMT":"666.00","sourceDate":"2020-02-20"},{"SOURCE_ROW_NUMBER":"442087","CITATION_NO":"4637103","CITATION_ISSUE_DT":"11/20/2019","DOCKET_NO":"WEVA 2020-0244","DECISION_DT":"04/15/2020","CFR_STANDARD_CODE":"75.523-3(b)(5)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"270.00","DECISION_PENALTY_AMT":"270.00","sourceDate":"2019-11-20"},{"SOURCE_ROW_NUMBER":"443899","CITATION_NO":"9162864","CITATION_ISSUE_DT":"11/18/2019","DOCKET_NO":"WEVA 2020-0244","DECISION_DT":"04/15/2020","CFR_STANDARD_CODE":"75.1731(b)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"270.00","DECISION_PENALTY_AMT":"270.00","sourceDate":"2019-11-18"},{"SOURCE_ROW_NUMBER":"387594","CITATION_NO":"9163461","CITATION_ISSUE_DT":"11/18/2019","DOCKET_NO":"WEVA 2020-0376","DECISION_DT":"08/21/2020","CFR_STANDARD_CODE":"72.630(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1738.00","DECISION_PENALTY_AMT":"898.00","sourceDate":"2019-11-18"},{"SOURCE_ROW_NUMBER":"385175","CITATION_NO":"9162866","CITATION_ISSUE_DT":"11/18/2019","DOCKET_NO":"WEVA 2020-0244","DECISION_DT":"04/15/2020","CFR_STANDARD_CODE":"75.1107-9(a)(1)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"214.00","DECISION_PENALTY_AMT":"214.00","sourceDate":"2019-11-18"},{"SOURCE_ROW_NUMBER":"330213","CITATION_NO":"9162865","CITATION_ISSUE_DT":"11/18/2019","DOCKET_NO":"WEVA 2020-0244","DECISION_DT":"04/15/2020","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"440.00","DECISION_PENALTY_AMT":"440.00","sourceDate":"2019-11-18"},{"SOURCE_ROW_NUMBER":"217331","CITATION_NO":"9163460","CITATION_ISSUE_DT":"11/13/2019","DOCKET_NO":"WEVA 2020-0244","DECISION_DT":"04/15/2020","CFR_STANDARD_CODE":"75.1103-5(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2993.00","DECISION_PENALTY_AMT":"1406.00","sourceDate":"2019-11-13"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":938,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":8,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":176,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":8,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":4,"firstDate":"2007-09-13","lastDate":"2015-10-26","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":122,"firstDate":"2007-11-05","lastDate":"2020-05-27","metrics":{"inspectors":471,"recentRows":0,"onSiteHours":16149.25,"inspectionHours":27560.25,"inspectionSamples":3167},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"278257","EVENT_NO":"6315291","INSPECTION_BEGIN_DT":"05/27/2020","INSPECTION_END_DT":"05/27/2020","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2020-05-27"},{"SOURCE_ROW_NUMBER":"392880","EVENT_NO":"6315289","INSPECTION_BEGIN_DT":"04/09/2020","INSPECTION_END_DT":"04/09/2020","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":".25","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2020-04-09"},{"SOURCE_ROW_NUMBER":"1152466","EVENT_NO":"6314423","INSPECTION_BEGIN_DT":"01/06/2020","INSPECTION_END_DT":"03/24/2020","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"159","SUM_TOTAL_ON_SITE_HOURS":"91","sourceDate":"2020-01-06"},{"SOURCE_ROW_NUMBER":"925138","EVENT_NO":"6315562","INSPECTION_BEGIN_DT":"10/01/2019","INSPECTION_END_DT":"12/30/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"497.5","SUM_TOTAL_ON_SITE_HOURS":"309.25","sourceDate":"2019-10-01"},{"SOURCE_ROW_NUMBER":"784357","EVENT_NO":"6312863","INSPECTION_BEGIN_DT":"07/01/2019","INSPECTION_END_DT":"09/27/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"9","SUM_TOTAL_INSP_HOURS":"723.5","SUM_TOTAL_ON_SITE_HOURS":"438.5","sourceDate":"2019-07-01"},{"SOURCE_ROW_NUMBER":"924937","EVENT_NO":"6312861","INSPECTION_BEGIN_DT":"04/01/2019","INSPECTION_END_DT":"06/26/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"10","SUM_TOTAL_INSP_HOURS":"748.25","SUM_TOTAL_ON_SITE_HOURS":"396.5","sourceDate":"2019-04-01"},{"SOURCE_ROW_NUMBER":"97471","EVENT_NO":"6314804","INSPECTION_BEGIN_DT":"03/19/2019","INSPECTION_END_DT":"03/26/2019","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"23.5","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2019-03-19"},{"SOURCE_ROW_NUMBER":"70532","EVENT_NO":"6313684","INSPECTION_BEGIN_DT":"03/11/2019","INSPECTION_END_DT":"03/12/2019","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"22","SUM_TOTAL_ON_SITE_HOURS":"12","sourceDate":"2019-03-11"},{"SOURCE_ROW_NUMBER":"642418","EVENT_NO":"6314801","INSPECTION_BEGIN_DT":"01/02/2019","INSPECTION_END_DT":"03/13/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"497.75","SUM_TOTAL_ON_SITE_HOURS":"273.5","sourceDate":"2019-01-02"},{"SOURCE_ROW_NUMBER":"398780","EVENT_NO":"6310450","INSPECTION_BEGIN_DT":"10/01/2018","INSPECTION_END_DT":"12/18/2018","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"7","SUM_TOTAL_INSP_HOURS":"556","SUM_TOTAL_ON_SITE_HOURS":"300","sourceDate":"2018-10-01"},{"SOURCE_ROW_NUMBER":"181863","EVENT_NO":"6304494","INSPECTION_BEGIN_DT":"09/27/2018","INSPECTION_END_DT":"09/27/2018","ACTIVITY_CODE":"E19","ACTIVITY":"Electrical Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2018-09-27"},{"SOURCE_ROW_NUMBER":"210778","EVENT_NO":"6311522","INSPECTION_BEGIN_DT":"09/25/2018","INSPECTION_END_DT":"09/27/2018","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"25","SUM_TOTAL_ON_SITE_HOURS":"14","sourceDate":"2018-09-25"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":138,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2020-Q2":{"hours":379,"employees":1,"production":0},"2020-Q1":{"hours":27131,"employees":48,"production":9881},"2019-Q4":{"hours":39601,"employees":68,"production":69110},"2019-Q3":{"hours":61260,"employees":104,"production":82373},"2019-Q2":{"hours":84480,"employees":124,"production":117608},"2019-Q1":{"hours":81828,"employees":124,"production":138317},"2018-Q4":{"hours":72026,"employees":119,"production":136684},"2018-Q3":{"hours":73599,"employees":127,"production":131989},"2018-Q2":{"hours":61856,"employees":126,"production":115552},"2018-Q1":{"hours":84836,"employees":138,"production":114062},"2017-Q4":{"hours":77487,"employees":142,"production":124785},"2017-Q3":{"hours":74442,"employees":123,"production":132327}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":32,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2011":{"hours":266640,"employees":125,"production":888887},"2012":{"hours":334109,"employees":167,"production":961441},"2013":{"hours":405224,"employees":196,"production":1013890},"2014":{"hours":414196,"employees":166,"production":928812},"2015":{"hours":253699,"employees":114,"production":656909},"2016":{"hours":250843,"employees":109,"production":532403},"2017":{"hours":305117,"employees":134,"production":482516},"2018":{"hours":292317,"employees":136,"production":498287},"2019":{"hours":267169,"employees":105,"production":407408},"2020":{"hours":27510,"employees":26,"production":9881}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":347,"firstDate":"2008-03-17","lastDate":"2019-11-18","metrics":{"recentRows":0,"doseOver100":89,"actDoseTotal":27561,"pelDoseTotal":20221},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"261434","EVENT_NO":"6315562","SURVEY_DATE":"11/18/2019","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"17","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2019-11-18"},{"SOURCE_ROW_NUMBER":"261433","EVENT_NO":"6315562","SURVEY_DATE":"11/18/2019","OCCUPATION_CD_DESC":"MAINTENANCE FOREMAN","MACHINE_CD":"20","MANUFACTURER_CD":"119","ACT_DOSE_85":"26","PEL_DOSE_90":"20","SURVEY_TYPE":"I","sourceDate":"2019-11-18"},{"SOURCE_ROW_NUMBER":"261432","EVENT_NO":"6315562","SURVEY_DATE":"11/18/2019","OCCUPATION_CD_DESC":"TRACTOR OPERATOR/MOTORMAN","MACHINE_CD":"25","MANUFACTURER_CD":"119","ACT_DOSE_85":"24","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2019-11-18"},{"SOURCE_ROW_NUMBER":"261431","EVENT_NO":"6315562","SURVEY_DATE":"11/18/2019","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"31","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2019-11-18"},{"SOURCE_ROW_NUMBER":"261407","EVENT_NO":"6312863","SURVEY_DATE":"09/18/2019","OCCUPATION_CD_DESC":"FIRE BOSS PRE-SHIFT EXAMINER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"36","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2019-09-18"},{"SOURCE_ROW_NUMBER":"261406","EVENT_NO":"6312863","SURVEY_DATE":"09/18/2019","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"20","MANUFACTURER_CD":"119","ACT_DOSE_85":"25","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2019-09-18"},{"SOURCE_ROW_NUMBER":"261405","EVENT_NO":"6312863","SURVEY_DATE":"09/18/2019","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"39","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2019-09-18"},{"SOURCE_ROW_NUMBER":"261404","EVENT_NO":"6312863","SURVEY_DATE":"09/18/2019","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"28","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2019-09-18"},{"SOURCE_ROW_NUMBER":"261403","EVENT_NO":"6312863","SURVEY_DATE":"09/18/2019","OCCUPATION_CD_DESC":"DISPATCHER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"4","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2019-09-18"},{"SOURCE_ROW_NUMBER":"261427","EVENT_NO":"6312863","SURVEY_DATE":"08/21/2019","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"23","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2019-08-21"},{"SOURCE_ROW_NUMBER":"261426","EVENT_NO":"6312863","SURVEY_DATE":"08/21/2019","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"43","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2019-08-21"},{"SOURCE_ROW_NUMBER":"261425","EVENT_NO":"6312863","SURVEY_DATE":"08/21/2019","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"34","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2019-08-21"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":329,"firstDate":"2008-04-23","lastDate":"2019-12-30","metrics":{"recentRows":0,"voidSamples":38,"maxQuartzPct":30.7,"validSamples":291,"quartzPctTotal":2010.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"104223","CASSETTE_NO":"58405176","SAMPLE_DT":"12/30/2019","QUARTZ_PCT":"04.6","QUARTZ_MICROGRAMS":"10","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-12-30"},{"SOURCE_ROW_NUMBER":"93288","CASSETTE_NO":"58405154","SAMPLE_DT":"12/30/2019","QUARTZ_PCT":"03.2","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"SCOOP CAR OPERATOR","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-12-30"},{"SOURCE_ROW_NUMBER":"84593","CASSETTE_NO":"58405173","SAMPLE_DT":"12/30/2019","QUARTZ_PCT":"05.0","QUARTZ_MICROGRAMS":"19","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-12-30"},{"SOURCE_ROW_NUMBER":"50698","CASSETTE_NO":"58405090","SAMPLE_DT":"12/30/2019","QUARTZ_PCT":"06.4","QUARTZ_MICROGRAMS":"29","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-12-30"},{"SOURCE_ROW_NUMBER":"75611","CASSETTE_NO":"58405357","SAMPLE_DT":"11/18/2019","QUARTZ_PCT":"04.6","QUARTZ_MICROGRAMS":"24","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-11-18"},{"SOURCE_ROW_NUMBER":"38888","CASSETTE_NO":"58405201","SAMPLE_DT":"11/18/2019","QUARTZ_PCT":"04.7","QUARTZ_MICROGRAMS":"9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-11-18"},{"SOURCE_ROW_NUMBER":"165771","CASSETTE_NO":"58405033","SAMPLE_DT":"11/06/2019","QUARTZ_PCT":"04.9","QUARTZ_MICROGRAMS":"17","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-11-06"},{"SOURCE_ROW_NUMBER":"149616","CASSETTE_NO":"58404968","SAMPLE_DT":"11/06/2019","QUARTZ_PCT":"05.0","QUARTZ_MICROGRAMS":"20","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-11-06"},{"SOURCE_ROW_NUMBER":"99551","CASSETTE_NO":"58405292","SAMPLE_DT":"11/06/2019","QUARTZ_PCT":"05.0","QUARTZ_MICROGRAMS":"20","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-11-06"},{"SOURCE_ROW_NUMBER":"63980","CASSETTE_NO":"58404973","SAMPLE_DT":"11/06/2019","QUARTZ_PCT":"06.1","QUARTZ_MICROGRAMS":"21","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-11-06"},{"SOURCE_ROW_NUMBER":"49569","CASSETTE_NO":"58404965","SAMPLE_DT":"11/06/2019","QUARTZ_PCT":"04.9","QUARTZ_MICROGRAMS":"16","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-11-06"},{"SOURCE_ROW_NUMBER":"48854","CASSETTE_NO":"58405024","SAMPLE_DT":"11/06/2019","QUARTZ_PCT":"05.5","QUARTZ_MICROGRAMS":"26","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-11-06"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":2698,"firstDate":"2007-12-21","lastDate":"2020-02-26","metrics":{"ss":560,"amountDue":1873639.76,"contested":90,"amountPaid":1705941.65,"recentRows":0,"section104d":13,"unterminated":6,"proposedPenalty":2624444},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2928993","VIOLATION_NO":"9246042","VIOLATION_ISSUE_DT":"02/26/2020","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/26/2020","PROPOSED_PENALTY":"217","AMOUNT_DUE":"217","AMOUNT_PAID":"217","CONTESTED_IND":"N","sourceDate":"2020-02-26"},{"SOURCE_ROW_NUMBER":"2928992","VIOLATION_NO":"9246041","VIOLATION_ISSUE_DT":"02/24/2020","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/24/2020","PROPOSED_PENALTY":"144","AMOUNT_DUE":"144","AMOUNT_PAID":"144","CONTESTED_IND":"N","sourceDate":"2020-02-24"},{"SOURCE_ROW_NUMBER":"2928991","VIOLATION_NO":"9246040","VIOLATION_ISSUE_DT":"02/24/2020","SIG_SUB":"N","PART_SECTION":"77.1605(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/24/2020","PROPOSED_PENALTY":"324","AMOUNT_DUE":"324","AMOUNT_PAID":"324","CONTESTED_IND":"N","sourceDate":"2020-02-24"},{"SOURCE_ROW_NUMBER":"2928990","VIOLATION_NO":"9246039","VIOLATION_ISSUE_DT":"02/20/2020","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/24/2020","PROPOSED_PENALTY":"217","AMOUNT_DUE":"217","AMOUNT_PAID":"217","CONTESTED_IND":"N","sourceDate":"2020-02-20"},{"SOURCE_ROW_NUMBER":"2928989","VIOLATION_NO":"9246038","VIOLATION_ISSUE_DT":"02/20/2020","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/24/2020","PROPOSED_PENALTY":"666","AMOUNT_DUE":"666","AMOUNT_PAID":"666","CONTESTED_IND":"N","sourceDate":"2020-02-20"},{"SOURCE_ROW_NUMBER":"2928988","VIOLATION_NO":"9246025","VIOLATION_ISSUE_DT":"02/20/2020","SIG_SUB":"N","PART_SECTION":"75.312(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/20/2020","PROPOSED_PENALTY":"144","AMOUNT_DUE":"144","AMOUNT_PAID":"144","CONTESTED_IND":"N","sourceDate":"2020-02-20"},{"SOURCE_ROW_NUMBER":"2928987","VIOLATION_NO":"9246024","VIOLATION_ISSUE_DT":"01/21/2020","SIG_SUB":"N","PART_SECTION":"75.904","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/21/2020","PROPOSED_PENALTY":"324","AMOUNT_DUE":"324","AMOUNT_PAID":"324","CONTESTED_IND":"N","sourceDate":"2020-01-21"},{"SOURCE_ROW_NUMBER":"2928986","VIOLATION_NO":"9246023","VIOLATION_ISSUE_DT":"01/13/2020","SIG_SUB":"N","PART_SECTION":"75.380(b)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/14/2020","PROPOSED_PENALTY":"217","AMOUNT_DUE":"217","AMOUNT_PAID":"217","CONTESTED_IND":"N","sourceDate":"2020-01-13"},{"SOURCE_ROW_NUMBER":"2928985","VIOLATION_NO":"9246022","VIOLATION_ISSUE_DT":"01/08/2020","SIG_SUB":"N","PART_SECTION":"75.1403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/08/2020","PROPOSED_PENALTY":"567","AMOUNT_DUE":"567","AMOUNT_PAID":"567","CONTESTED_IND":"N","sourceDate":"2020-01-08"},{"SOURCE_ROW_NUMBER":"2928984","VIOLATION_NO":"9246021","VIOLATION_ISSUE_DT":"01/08/2020","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/09/2020","PROPOSED_PENALTY":"351","AMOUNT_DUE":"351","AMOUNT_PAID":"351","CONTESTED_IND":"N","sourceDate":"2020-01-08"},{"SOURCE_ROW_NUMBER":"2930902","VIOLATION_NO":"9163466","VIOLATION_ISSUE_DT":"12/09/2019","SIG_SUB":"N","PART_SECTION":"75.1714-8(a)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/17/2019","PROPOSED_PENALTY":"123","AMOUNT_DUE":"123","AMOUNT_PAID":"123","CONTESTED_IND":"N","sourceDate":"2019-12-09"},{"SOURCE_ROW_NUMBER":"2930819","VIOLATION_NO":"4637103","VIOLATION_ISSUE_DT":"11/20/2019","SIG_SUB":"N","PART_SECTION":"75.523-3(b)(5)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/21/2019","PROPOSED_PENALTY":"270","AMOUNT_DUE":"270","AMOUNT_PAID":"270","CONTESTED_IND":"N","sourceDate":"2019-11-20"}]}],"safety":{"href":"/api/v1/mines/4609230/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609230/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","heading":"Main mine fan examinations and records.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.312","part":"75","subchapter":"O","subpart":"D","id":"75.312","citation":"30 CFR 75.312","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.904","heading":"Identification of circuit breakers.","id":"75.904","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-J/section-75.904","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"J","subpartHeading":"Subpart J—Underground Low- and Medium-Voltage Alternating Current Circuits","text":"[Statutory Provisions]\n\nCircuit breakers shall be marked for identification.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.380","heading":"Escapeways; bituminous and lignite mines.","id":"75.380","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.380","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Except in situations addressed in § 75.381, § 75.385 and § 75.386, at least two separate and distinct travelable passageways shall be designated as escapeways and shall meet the requirements of this section.\n\n(b) (1) Escapeways shall be provided from each working section, and each area where mechanized mining equipment is being installed or removed, continuous to the surface escape drift opening or continuous to the escape shaft or slope facilities to the surface.\n\n(2) During equipment installation, these escapeways shall begin at the projected location for the section loading point. During equipment removal, they shall begin at the location of the last loading point.\n\n(c) The two separate and distinct escapeways required by this section shall not end at a common shaft, slope, or drift opening, except that multiple compartment shafts or slopes separated by walls constructed of noncombustible material may be used as separate and distinct passageways.\n\n(d) Each escapeway shall be—\n\n(1) Maintained in a safe condition to always assure passage of anyone, including disabled persons;\n\n(2) Clearly marked to show the route and direction of travel to the surface;\n\n(3) Maintained to at least a height of 5 feet from the mine floor to the mine roof, excluding the thickness of any roof support, except that the escapeways shall be maintained to at least the height of the coalbed, excluding the thickness of any roof support, where the coalbed is less than 5 feet. In areas of mines where escapeways pass through doors, the height may be less than 5 feet, provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. In areas of mines developed before November 16, 1992, where escapeways pass over or under overcasts or undercasts, the height may be less than 5 feet provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient height is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(4) Maintained at least 6 feet wide except—\n\n(i) Where necessary supplemental roof support is installed, the escapeway shall not be less than 4 feet wide; or\n\n(ii) Where the route of travel passes through doors or other permanent ventilation controls, the escapeway shall be at least 4 feet wide to enable miners to escape quickly in an emergency, or\n\n(iii) Where the alternate escapeway passes through doors or other permanent ventilation controls or where supplemental roof support is required and sufficient width is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher, or\n\n(iv) Where mobile equipment near working sections, and other equipment essential to the ongoing operation of longwall sections, is necessary during normal mining operations, such as material cars containing rock dust or roof control supplies, or is to be used for the evacuation of miners off the section in the event of an emergency. In any instance, escapeways shall be of sufficient width to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(5) Located to follow the most direct, safe and practical route to the nearest mine opening suitable for the safe evacuation of miners; and\n\n(6) Provided with ladders, stairways, ramps, or similar facilities where the escapeways cross over obstructions.\n\n(7) Provided with a continuous, durable directional lifeline or equivalent device that shall be—\n\n(i) Installed and maintained throughout the entire length of each escapeway as defined in paragraph (b)(1) of this section;\n\n(ii) Flame-resistant in accordance with the requirements of part 18 of this chapter upon replacement of existing lifelines; but in no case later than June 15, 2009;\n\n(iii) Marked with a reflective material every 25 feet;\n\n(iv) Located in such a manner for miners to use effectively to escape;\n\n(v) Equipped with one directional indicator cone securely attached to the lifeline, signifying the route of escape, placed at intervals not exceeding 100 feet. Cones shall be installed so that the tapered section points inby;\n\n(vi) Equipped with one sphere securely attached to the lifeline at each intersection where personnel doors are installed in adjacent crosscuts;\n\n(vii) Equipped with two securely attached cones, installed consecutively with the tapered section pointing inby, to signify an attached branch line is immediately ahead.\n\n(A) A branch line leading from the lifeline to an SCSR cache will be marked with four cones with the base sections in contact to form two diamond shapes. The cones must be placed within reach of the lifeline.\n\n(B) A branch line leading from the lifeline to a refuge alternative will be marked with a rigid spiraled coil at least eight inches in length. The spiraled coil must be placed within reach of the lifeline (see Illustration 1 below).\n\n(e) Surface openings shall be adequately protected to prevent surface fires, fumes, smoke, and flood water from entering the mine.\n\n(f) Primary escapeway. (1) One escapeway that is ventilated with intake air shall be designated as the primary escapeway. The primary escapeway shall have a higher ventilation pressure than the belt entry unless the mine operator submits an alternative in the mine ventilation plan to protect the integrity of the primary escapeway, based on mine specific conditions, which is approved by the district manager.\n\n(2) Paragraphs (f)(3) through (f)(7) of this section apply as follows:\n\n(i) To all areas of a primary escapeway developed on or after November 16, 1992;\n\n(ii) Effective as of June 10, 1997, to all areas of a primary escapeway developed between March 30, 1970 and November 16, 1992; and\n\n(iii) Effective as of June 10, 1997, to all areas of the primary escapeway developed prior to March 30, 1970 where separation of the belt and trolley haulage entries from the primary escapeway existed prior to November 16, 1992.\n\n(3) The following equipment is not permitted in the primary escapeway:\n\n(i) Mobile equipment hauling coal except for hauling coal incidental to cleanup or maintenance of the primary escapeway.\n\n(ii) Compressors, except—\n\n(A) Compressors necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Compressors that are components of equipment such as locomotives and rock dusting machines; and\n\n(C) Compressors of less than five horsepower.\n\n(iii) Underground transformer stations, battery charging stations, substations, and rectifiers except—\n\n(A) Where necessary to maintain the escapeway in safe, travelable condition; and\n\n(B) Battery charging stations and rectifiers and power centers with transformers that are either dry-type or contain nonflammable liquid, provided they are located on or near a working section and are moved as the section advances or retreats.\n\n(iv) Water pumps, except—\n\n(A) Water pumps necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Submersible pumps;\n\n(C) Permissible pumps and associated permissible switchgear;\n\n(D) Pumps located on or near a working section that are moved as the section advances or retreats;\n\n(E) Pumps installed in anthracite mines; and\n\n(F) Small portable pumps.\n\n(4) Mobile equipment operated in the primary escapeway, except for continuous miners and as provided in paragraphs (f)(5), (f)(6), and (f)(7) of this section, shall be equipped with a fire suppression system installed according to §§ 75.1107-3 through 75.1107-16 that is—\n\n(i) Manually operated and attended continuously by a person trained in the systems function and use, or\n\n(ii) A multipurpose dry chemical type capable of both automatic and manual activation.\n\n(5) Personnel carriers and small mobile equipment designed and used only for carrying people and small hand tools may be operated in primary escapeways if—\n\n(i) The equipment is provided with a multipurpose dry chemical type fire suppression system capable of both automatic and manual activation, and the suppression system is suitable for the intended application and is listed or approved by a nationally recognized independent testing laboratory, or,\n\n(ii) Battery powered and provided with two 10 pound multipurpose dry chemical portable fire extinguishers.\n\n(6) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment not provided with a fire suppression system may operate in the primary escapeway if no one is inby except those persons directly engaged in using or moving the equipment.\n\n(7) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment designated and used only as emergency vehicles or ambulances, may be operated in the primary escapeway without fire suppression systems.\n\n(g) Except where separation of belt and trolley haulage entries from designated escapeways did not exist before November 15, 1992, and except as provided in § 75.350(c), the primary escapeway must be separated from belt and trolley haulage entries for its entire length, to and including the first connecting crosscut outby each loading point except when a greater or lesser distance for this separation is specified and approved in the mine ventilation plan and does not pose a hazard to miners.\n\n(h) Alternate escapeway. One escapeway shall be designated as the alternate escapeway. The alternate escapeway shall be separated from the primary escapeway for its entire length, except that the alternate and primary escapeways may be ventilated from a common intake air shaft or slope opening.\n\n(i) Mechanical escape facilities shall be provided and maintained for—\n\n(1) Each shaft that is part of a designated escapeway and is greater than 50 feet in depth; and\n\n(2) Each slope from the coal seam to the surface that is part of a designated escapeway and is inclined more than 9 degrees from the horizontal.\n\n(j) Within 30 minutes after mine personnel on the surface have been notified of an emergency requiring evacuation, mechanical escape facilities provided under paragraph (i) of this section shall be operational at the bottom of shaft and slope openings that are part of escapeways.\n\n(k) Except where automatically activated hoisting equipment is used, the bottom of each shaft or slope opening that is part of a designated escapeway shall be equipped with a means of signaling a surface location where a person is always on duty when anyone is underground. When the signal is activated or the evacuation of persons underground is necessary, the person shall assure that mechanical escape facilities are operational as required by paragraph (j) of this section.\n\n(l)(1) Stairways or mechanical escape facilities shall be installed in shafts that are part of the designated escapeways and that are 50 feet or less in depth, except ladders may be used in shafts that are part of the designated escapeways and that are 5 feet or less in depth.\n\n(2) Stairways shall be constructed of concrete or metal, set on an angle not to exceed 45 degrees from the horizontal, and equipped on the open side with handrails. In addition, landing platforms that are at least 2 feet by 4 feet shall be installed at intervals not to exceed 20 vertical feet on the stairways and equipped on the open side with handrails.\n\n(3) Ladders shall be constructed of metal, anchored securely, and set on an angle not to exceed 60 degrees from the horizontal.\n\n(m) A travelway designed to prevent slippage shall be provided in slope and drift openings that are part of designated escapeways, unless mechanical escape facilities are installed.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 69 FR 17530, Apr. 2, 2004; 71 FR 12269, Mar. 9, 2006; 71 FR 71452, Dec. 8, 2006; 73 FR 80613, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403","heading":"Other safeguards.","id":"75.1403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"[Statutory Provisions]\n\nOther safeguards adequate, in the judgment of an authorized representative of the Secretary, to minimize hazards with respect to transportation of men and materials shall be provided.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","heading":"Reporting SCSR inventory and malfunctions; retention of SCSRs.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-8","part":"75","subchapter":"O","subpart":"R","id":"75.1714-8","citation":"30 CFR 75.1714-8","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.523-3","heading":"Automatic emergency-parking brakes.","id":"75.523-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"(a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking brakes in accordance with the following schedule.\n\n(1) On and after May 23, 1989—\n\n(i) All new equipment ordered; and\n\n(ii) All equipment originally furnished with or retrofitted with automatic emergency-parking brakes which meet the requirements of this section.\n\n(2) On and after May 23, 1991, all other equipment.\n\n(b) Automatic emergency-parking brakes shall—\n\n(1) Be activated immediately by the emergency deenergization device required by 30 CFR 75.523-1 and 75.523-2;\n\n(2) Engage automatically within 5.0 seconds when the equipment is deenergized;\n\n(3) Safely bring the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(4) Hold the equipment stationary despite any contraction of brake parts, exhaustion of any non-mechanical source of energy, or leakage; and\n\n(5) Release only by a manual control that does not operate any other equipment function.\n\n(c) Automatic emergency-parking brakes shall include a means in the equipment operator's compartment to—\n\n(1) Apply the brakes manually without deenergizing the equipment; and\n\n(2) Release and reengage the brakes without energizing the equipment.\n\n(d) On and after November 24, 1989, rubber-tired, self-propelled electric face equipment not covered by paragraph (a) of this section shall be equipped with a means incorporated on the equipment and operable from each tramming station to hold the equipment stationary—\n\n(1) On the maximum grade on which it is operated; and\n\n(2) Despite any contraction of components, exhaustion of any non-mechanical source of energy, or leakage.\n\n(e) The brake systems required by paragraphs (a) or (d) of this section shall be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n[54 FR 12412, Mar. 24, 1989]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609230","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}