{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4609207","name":"Mine No 2","status":"Active","status_date":"2025-07-28","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Mcdowell","nearest_town":"Caretta","operator_id":"0050384","operator_name":"Harman Branch Mining Inc","controller_id":"0067993","controller_name":"Hung  Q  Nguyen","district":"C04","office":"Logan WV Field Office","employees":12,"latitude":37.334444,"longitude":-81.688056},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":4451},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609207","name":"Mine No 2"},"operator":{"type":"operator","id":"0050384","name":"Harman Branch Mining Inc"},"controller":{"type":"controller","id":"0067993","name":"Hung  Q  Nguyen"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C16007","name":"Daniel S  Jordan"},"object":{"type":"mine","id":"4609207","name":"Mine No 2"},"validFrom":"2002-06-11","validTo":"2007-02-27","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609207|C16007|2002-06-11|2007-02-27"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0050384","name":"Harman Branch Mining Inc"},"object":{"type":"mine","id":"4609207","name":"Mine No 2"},"validFrom":"2007-02-28","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609207|0050384|2007-02-28|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0067993","name":"Hung  Q  Nguyen"},"object":{"type":"mine","id":"4609207","name":"Mine No 2"},"validFrom":"2007-02-28","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609207|0067993|2007-02-28|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0067993","name":"Hung  Q  Nguyen"},"object":{"type":"operator","id":"0050384","name":"Harman Branch Mining Inc"},"validFrom":"2007-02-28","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609207","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609207|0050384|2007-02-28|0067993|2007-02-28|9538"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C16007","name":"Daniel S  Jordan"},"object":{"type":"operator","id":"0050384","name":"Harman Branch Mining Inc"},"validFrom":"2007-02-28","validTo":"2007-02-27","current":false,"derived":true,"evidenceMineId":"4609207","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609207|0050384|2007-02-28|C16007|2002-06-11|97991"}}],"coverage":{"historyRecords":2,"edgeCount":5,"intervalAnomalies":1,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":9,"firstDate":"2009-10-07","lastDate":"2026-02-19","metrics":{"daysLost":464,"injuries":9,"fatalities":0,"recentRows":3,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"154559","DOCUMENT_NO":"220260790003","ACCIDENT_DT":"02/19/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","NARRATIVE":"Employee went into con x 2 to get a box of belt splices. After picking up the box, they turned around to exit the con x and felt pain in left knee. Employee went for medical treatment.","sourceDate":"2026-02-19"},{"SOURCE_ROW_NUMBER":"188873","DOCUMENT_NO":"220242470002","ACCIDENT_DT":"08/20/2024","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"211","NARRATIVE":"EE was helping to move a trailer car loaded with timbers. The EE was located behind the trailer. As the scoop was pushing the car backwards, the car suddenly moved towards the inby rib. This movement caught the employee's right foot between the car and the mine floor injuring EE's right foot.","sourceDate":"2024-08-20"},{"SOURCE_ROW_NUMBER":"193209","DOCUMENT_NO":"220232830002","ACCIDENT_DT":"09/25/2023","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in wielding or throwing objects","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"188","NARRATIVE":"Employee doing regular activity while shoveling belt and felt pain in lower back.","sourceDate":"2023-09-25"},{"SOURCE_ROW_NUMBER":"64097","DOCUMENT_NO":"220202380004","ACCIDENT_DT":"08/12/2020","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE was bringing the steel out of the hole. EE reached to grab the steel to keep from falling on ground & instead of hitting the lever to run the steel on out EE accidentally hit the rotation and a burr on the steel caught EE's glove and wrapped EE's arm up in steel.","sourceDate":"2020-08-12"},{"SOURCE_ROW_NUMBER":"47015","DOCUMENT_NO":"220182470001","ACCIDENT_DT":"08/27/2018","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"Injured Person stated while changing out a bottom roller IP hung one side and went to pull up to hook other side and the side IP first hooked came off causing the bottom roller to strike IP in right side. There was no witness and IP didn't tell nobody till next day.","sourceDate":"2018-08-27"},{"SOURCE_ROW_NUMBER":"94165","DOCUMENT_NO":"220133600001","ACCIDENT_DT":"12/17/2013","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"15","NARRATIVE":"Electrician /Mechanic kneel down and turned around and felt his knee hurting. EE had prior surgery on his knee before employment at mine. EE said that he had forgotten to wear his knee brace. The EE said he would RTW the next day. He did not go to hospital after leaving mine property.","sourceDate":"2013-12-17"},{"SOURCE_ROW_NUMBER":"193208","DOCUMENT_NO":"220113490002","ACCIDENT_DT":"12/01/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Continuous miner helper, Coal mole helper, Bridgeman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Miner helper went to pick up miner cable to move out of haul way, hurting his back.","sourceDate":"2011-12-01"},{"SOURCE_ROW_NUMBER":"210487","DOCUMENT_NO":"220112340048","ACCIDENT_DT":"08/10/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"45","NARRATIVE":"Electrician/mechanic was change a tire on std shuttle car, when he went to put wedge under tire, the tire fell off the shuttle car hub and landing on Electricians ankle. Electrician continued working on wheel until he completed job then leaving to outside to go home.","sourceDate":"2011-08-10"},{"SOURCE_ROW_NUMBER":"227728","DOCUMENT_NO":"220092990033","ACCIDENT_DT":"10/07/2009","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"Hanging cable - sprained shoulder muscle.","sourceDate":"2009-10-07"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2025-07-28","lastDate":"2025-07-28","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":782,"firstDate":"2007-07-24","lastDate":"2026-07-16","metrics":{"ss":163,"delinquent":757,"recentRows":243,"paidPenalty":253111,"proposedPenalty":351673,"currentAssessment":253111},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2889156","VIOLATION_NO":"5132066","ISSUE_DT":"07/16/2026","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-07-16"},{"SOURCE_ROW_NUMBER":"2889155","VIOLATION_NO":"5132065","ISSUE_DT":"07/16/2026","CFR_STANDARD_CD":"75.333(c)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-07-16"},{"SOURCE_ROW_NUMBER":"2889154","VIOLATION_NO":"5132063","ISSUE_DT":"07/09/2026","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-07-09"},{"SOURCE_ROW_NUMBER":"2889153","VIOLATION_NO":"5132062","ISSUE_DT":"07/09/2026","CFR_STANDARD_CD":"75.1731(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-07-09"},{"SOURCE_ROW_NUMBER":"2889152","VIOLATION_NO":"5132061","ISSUE_DT":"07/09/2026","CFR_STANDARD_CD":"75.1103-8(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-07-09"},{"SOURCE_ROW_NUMBER":"2889151","VIOLATION_NO":"5132060","ISSUE_DT":"07/09/2026","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-07-09"},{"SOURCE_ROW_NUMBER":"2889150","VIOLATION_NO":"5132059","ISSUE_DT":"07/09/2026","CFR_STANDARD_CD":"75.516","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-07-09"},{"SOURCE_ROW_NUMBER":"2889149","VIOLATION_NO":"5132058","ISSUE_DT":"07/09/2026","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"245.00","CURRENT_ASSESSMENT_AMT":"245.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-07-09"},{"SOURCE_ROW_NUMBER":"2889148","VIOLATION_NO":"5132057","ISSUE_DT":"07/08/2026","CFR_STANDARD_CD":"75.604(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-07-08"},{"SOURCE_ROW_NUMBER":"2889147","VIOLATION_NO":"5132056","ISSUE_DT":"07/08/2026","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-07-08"},{"SOURCE_ROW_NUMBER":"2889146","VIOLATION_NO":"5132055","ISSUE_DT":"07/08/2026","CFR_STANDARD_CD":"75.604(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"504.00","CURRENT_ASSESSMENT_AMT":"504.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-07-08"},{"SOURCE_ROW_NUMBER":"2889145","VIOLATION_NO":"5132054","ISSUE_DT":"07/08/2026","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-07-08"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":470,"firstDate":"2009-11-23","lastDate":"2026-01-27","metrics":{"appeals":0,"decisions":470,"recentRows":164,"decisionPenalty":183214,"originalPenalty":288571},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"460870","VIOLATION_NO":"5095415","DOCKET_NO":"WEVA 2026-0048","DECISION_DT":"01/27/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"151.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-01-27"},{"SOURCE_ROW_NUMBER":"460869","VIOLATION_NO":"5091154","DOCKET_NO":"WEVA 2026-0048","DECISION_DT":"01/27/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"267.00","DECISION_PENALTY_AMT":"267.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-01-27"},{"SOURCE_ROW_NUMBER":"460868","VIOLATION_NO":"5090857","DOCKET_NO":"WEVA 2026-0048","DECISION_DT":"01/27/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"336.00","DECISION_PENALTY_AMT":"156.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-01-27"},{"SOURCE_ROW_NUMBER":"460420","VIOLATION_NO":"5090860","DOCKET_NO":"WEVA 2026-0048","DECISION_DT":"01/27/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"336.00","DECISION_PENALTY_AMT":"156.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-01-27"},{"SOURCE_ROW_NUMBER":"459914","VIOLATION_NO":"5095414","DOCKET_NO":"WEVA 2026-0048","DECISION_DT":"01/27/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"151.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-01-27"},{"SOURCE_ROW_NUMBER":"459830","VIOLATION_NO":"5091155","DOCKET_NO":"WEVA 2026-0048","DECISION_DT":"01/27/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"151.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-01-27"},{"SOURCE_ROW_NUMBER":"459829","VIOLATION_NO":"5090858","DOCKET_NO":"WEVA 2026-0048","DECISION_DT":"01/27/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"151.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-01-27"},{"SOURCE_ROW_NUMBER":"459637","VIOLATION_NO":"5090856","DOCKET_NO":"WEVA 2026-0048","DECISION_DT":"01/27/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"151.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-01-27"},{"SOURCE_ROW_NUMBER":"167470","VIOLATION_NO":"5091653","DOCKET_NO":"WEVA 2026-0048","DECISION_DT":"01/27/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"151.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-01-27"},{"SOURCE_ROW_NUMBER":"167469","VIOLATION_NO":"5090861","DOCKET_NO":"WEVA 2026-0048","DECISION_DT":"01/27/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1126.00","DECISION_PENALTY_AMT":"231.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-01-27"},{"SOURCE_ROW_NUMBER":"167468","VIOLATION_NO":"5090855","DOCKET_NO":"WEVA 2026-0048","DECISION_DT":"01/27/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"226.00","DECISION_PENALTY_AMT":"226.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-01-27"},{"SOURCE_ROW_NUMBER":"167023","VIOLATION_NO":"5091655","DOCKET_NO":"WEVA 2026-0048","DECISION_DT":"01/27/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"151.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-01-27"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":1302,"firstDate":"2007-08-21","lastDate":"2026-09-28","metrics":{"recentRows":614,"cpdmSamples":575,"voidSamples":184,"validSamples":1118,"maxConcentration":4.643,"concentrationTotal":440.124},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2944014","SMP_TAKEN_DT":"9/28/2026","CONC":".728","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-09-28"},{"SOURCE_ROW_NUMBER":"2688854","SMP_TAKEN_DT":"9/24/2026","CONC":".296","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-09-24"},{"SOURCE_ROW_NUMBER":"2262351","SMP_TAKEN_DT":"9/22/2026","CONC":".208","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-09-22"},{"SOURCE_ROW_NUMBER":"2773995","SMP_TAKEN_DT":"8/5/2026","CONC":".082","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-08-05"},{"SOURCE_ROW_NUMBER":"2347460","SMP_TAKEN_DT":"8/3/2026","CONC":".096","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-08-03"},{"SOURCE_ROW_NUMBER":"2603142","SMP_TAKEN_DT":"7/31/2026","CONC":".031","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"UNREPRESENTATIVE SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-07-31"},{"SOURCE_ROW_NUMBER":"2091649","SMP_TAKEN_DT":"7/28/2026","CONC":".086","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-07-28"},{"SOURCE_ROW_NUMBER":"2517707","SMP_TAKEN_DT":"7/27/2026","CONC":".193","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-07-27"},{"SOURCE_ROW_NUMBER":"1060479","CASS_NUM":"58593576","SMP_TAKEN_DT":"7/22/2026","CONC":".445","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-07-22"},{"SOURCE_ROW_NUMBER":"1025130","CASS_NUM":"58593566","SMP_TAKEN_DT":"7/22/2026","CONC":".541","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-07-22"},{"SOURCE_ROW_NUMBER":"828682","CASS_NUM":"58593594","SMP_TAKEN_DT":"7/22/2026","CONC":".151","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-07-22"},{"SOURCE_ROW_NUMBER":"537874","CASS_NUM":"58593366","SMP_TAKEN_DT":"7/22/2026","CONC":".245","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-07-22"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":4,"firstDate":"2008-04-24","lastDate":"2020-10-16","metrics":{"linkedIssuances":4},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":470,"firstDate":"2008-05-23","lastDate":"2025-10-14","metrics":{"decisions":470,"ssChanged":43,"recentRows":130,"decisionPenalty":183214,"proposedPenalty":288571},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"223275","CITATION_NO":"5091655","CITATION_ISSUE_DT":"10/14/2025","DOCKET_NO":"WEVA 2026-0048","DECISION_DT":"01/27/2026","CFR_STANDARD_CODE":"75.333(h)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"151.00","sourceDate":"2025-10-14"},{"SOURCE_ROW_NUMBER":"450261","CITATION_NO":"5091154","CITATION_ISSUE_DT":"10/08/2025","DOCKET_NO":"WEVA 2026-0048","DECISION_DT":"01/27/2026","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"267.00","DECISION_PENALTY_AMT":"267.00","sourceDate":"2025-10-08"},{"SOURCE_ROW_NUMBER":"336510","CITATION_NO":"5091654","CITATION_ISSUE_DT":"10/08/2025","DOCKET_NO":"WEVA 2026-0048","DECISION_DT":"01/27/2026","CFR_STANDARD_CODE":"75.1101-10","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"151.00","sourceDate":"2025-10-08"},{"SOURCE_ROW_NUMBER":"223385","CITATION_NO":"5091652","CITATION_ISSUE_DT":"10/08/2025","DOCKET_NO":"WEVA 2026-0048","DECISION_DT":"01/27/2026","CFR_STANDARD_CODE":"75.1731(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"151.00","sourceDate":"2025-10-08"},{"SOURCE_ROW_NUMBER":"167859","CITATION_NO":"5091653","CITATION_ISSUE_DT":"10/08/2025","DOCKET_NO":"WEVA 2026-0048","DECISION_DT":"01/27/2026","CFR_STANDARD_CODE":"75.1731(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"151.00","sourceDate":"2025-10-08"},{"SOURCE_ROW_NUMBER":"110390","CITATION_NO":"5091155","CITATION_ISSUE_DT":"10/08/2025","DOCKET_NO":"WEVA 2026-0048","DECISION_DT":"01/27/2026","CFR_STANDARD_CODE":"75.1100-3","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"151.00","sourceDate":"2025-10-08"},{"SOURCE_ROW_NUMBER":"223517","CITATION_NO":"5095414","CITATION_ISSUE_DT":"08/18/2025","DOCKET_NO":"WEVA 2026-0048","DECISION_DT":"01/27/2026","CFR_STANDARD_CODE":"75.380(d)(1)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"151.00","sourceDate":"2025-08-18"},{"SOURCE_ROW_NUMBER":"223406","CITATION_NO":"5095415","CITATION_ISSUE_DT":"08/18/2025","DOCKET_NO":"WEVA 2026-0048","DECISION_DT":"01/27/2026","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"151.00","sourceDate":"2025-08-18"},{"SOURCE_ROW_NUMBER":"393136","CITATION_NO":"5090861","CITATION_ISSUE_DT":"08/07/2025","DOCKET_NO":"WEVA 2026-0048","DECISION_DT":"01/27/2026","CFR_STANDARD_CODE":"77.502","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1126.00","DECISION_PENALTY_AMT":"231.00","sourceDate":"2025-08-07"},{"SOURCE_ROW_NUMBER":"223379","CITATION_NO":"5090860","CITATION_ISSUE_DT":"08/07/2025","DOCKET_NO":"WEVA 2026-0048","DECISION_DT":"01/27/2026","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"336.00","DECISION_PENALTY_AMT":"156.00","sourceDate":"2025-08-07"},{"SOURCE_ROW_NUMBER":"450131","CITATION_NO":"5090856","CITATION_ISSUE_DT":"08/06/2025","DOCKET_NO":"WEVA 2026-0048","DECISION_DT":"01/27/2026","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"151.00","sourceDate":"2025-08-06"},{"SOURCE_ROW_NUMBER":"393662","CITATION_NO":"5090857","CITATION_ISSUE_DT":"08/06/2025","DOCKET_NO":"WEVA 2026-0048","DECISION_DT":"01/27/2026","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"336.00","DECISION_PENALTY_AMT":"156.00","sourceDate":"2025-08-06"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":75,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":20,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2007-02-28","lastDate":"2007-02-28","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":117,"firstDate":"2007-05-30","lastDate":"2026-07-30","metrics":{"inspectors":236,"recentRows":32,"onSiteHours":3691.25,"inspectionHours":6112.75,"inspectionSamples":873},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"342525","EVENT_NO":"F00CDD9","INSPECTION_BEGIN_DT":"07/30/2026","INSPECTION_END_DT":"07/30/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2026-07-30"},{"SOURCE_ROW_NUMBER":"500616","EVENT_NO":"7047949","INSPECTION_BEGIN_DT":"07/01/2026","INSPECTION_END_DT":"07/23/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"103.25","SUM_TOTAL_ON_SITE_HOURS":"67.25","sourceDate":"2026-07-01"},{"SOURCE_ROW_NUMBER":"1161675","EVENT_NO":"F00D994","INSPECTION_BEGIN_DT":"04/03/2026","INSPECTION_END_DT":"04/28/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"99.25","SUM_TOTAL_ON_SITE_HOURS":"65.5","sourceDate":"2026-04-03"},{"SOURCE_ROW_NUMBER":"109809","EVENT_NO":"F020A5E","INSPECTION_BEGIN_DT":"01/22/2026","INSPECTION_END_DT":"03/24/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"153.25","SUM_TOTAL_ON_SITE_HOURS":"96","sourceDate":"2026-01-22"},{"SOURCE_ROW_NUMBER":"407786","EVENT_NO":"F00EB38","INSPECTION_BEGIN_DT":"12/18/2025","INSPECTION_END_DT":"12/18/2025","ACTIVITY_CODE":"E19","ACTIVITY":"Electrical Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2025-12-18"},{"SOURCE_ROW_NUMBER":"470763","EVENT_NO":"F017F39","INSPECTION_BEGIN_DT":"10/08/2025","INSPECTION_END_DT":"12/09/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"94.25","SUM_TOTAL_ON_SITE_HOURS":"60.75","sourceDate":"2025-10-08"},{"SOURCE_ROW_NUMBER":"961863","EVENT_NO":"F010DD2","INSPECTION_BEGIN_DT":"08/18/2025","INSPECTION_END_DT":"08/18/2025","ACTIVITY_CODE":"E19","ACTIVITY":"Electrical Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2025-08-18"},{"SOURCE_ROW_NUMBER":"239910","EVENT_NO":"F02A965","INSPECTION_BEGIN_DT":"07/28/2025","INSPECTION_END_DT":"09/02/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"90.5","SUM_TOTAL_ON_SITE_HOURS":"65.25","sourceDate":"2025-07-28"},{"SOURCE_ROW_NUMBER":"790969","EVENT_NO":"F020A43","INSPECTION_BEGIN_DT":"06/05/2025","INSPECTION_END_DT":"06/05/2025","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2025-06-05"},{"SOURCE_ROW_NUMBER":"984087","EVENT_NO":"6320798","INSPECTION_BEGIN_DT":"05/14/2025","INSPECTION_END_DT":"05/21/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"40","SUM_TOTAL_ON_SITE_HOURS":"28","sourceDate":"2025-05-14"},{"SOURCE_ROW_NUMBER":"528996","EVENT_NO":"7048924","INSPECTION_BEGIN_DT":"03/19/2025","INSPECTION_END_DT":"03/19/2025","ACTIVITY_CODE":"E19","ACTIVITY":"Electrical Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2025-03-19"},{"SOURCE_ROW_NUMBER":"811558","EVENT_NO":"F01D4AD","INSPECTION_BEGIN_DT":"01/02/2025","INSPECTION_END_DT":"01/21/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"57.25","SUM_TOTAL_ON_SITE_HOURS":"38.5","sourceDate":"2025-01-02"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":174,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2026-Q2":{"hours":7097,"employees":14,"production":19929},"2026-Q1":{"hours":5771,"employees":13,"production":15769},"2025-Q4":{"hours":8003,"employees":14,"production":16495},"2025-Q3":{"hours":4658,"employees":14,"production":15000},"2025-Q2":{"hours":7350,"employees":20,"production":18212},"2025-Q1":{"hours":7789,"employees":20,"production":20041},"2024-Q4":{"hours":11123,"employees":21,"production":34703},"2024-Q3":{"hours":10110,"employees":21,"production":29848},"2024-Q2":{"hours":12211,"employees":21,"production":30612},"2024-Q1":{"hours":10934,"employees":21,"production":26763},"2023-Q4":{"hours":11814,"employees":19,"production":29750},"2023-Q3":{"hours":9593,"employees":19,"production":23069}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":32,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017":{"hours":26869,"employees":20,"production":34526},"2018":{"hours":50876,"employees":27,"production":99206},"2019":{"hours":40184,"employees":23,"production":112876},"2020":{"hours":22374,"employees":16,"production":56733},"2021":{"hours":31429,"employees":16,"production":77159},"2022":{"hours":34911,"employees":18,"production":87579},"2023":{"hours":44195,"employees":19,"production":112627},"2024":{"hours":44378,"employees":21,"production":121926},"2025":{"hours":27800,"employees":17,"production":69748},"2026":{"hours":12868,"employees":14,"production":35698}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":130,"firstDate":"2008-02-12","lastDate":"2026-04-22","metrics":{"recentRows":38,"doseOver100":3,"actDoseTotal":6103,"pelDoseTotal":4191},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"259429","EVENT_NO":"F00D994","SURVEY_DATE":"04/22/2026","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"40","ACT_DOSE_85":"34","PEL_DOSE_90":"14","SURVEY_TYPE":"I","sourceDate":"2026-04-22"},{"SOURCE_ROW_NUMBER":"259428","EVENT_NO":"F00D994","SURVEY_DATE":"04/22/2026","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"27","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2026-04-22"},{"SOURCE_ROW_NUMBER":"259427","EVENT_NO":"F00D994","SURVEY_DATE":"04/22/2026","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"35","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2026-04-22"},{"SOURCE_ROW_NUMBER":"259426","EVENT_NO":"F00D994","SURVEY_DATE":"04/22/2026","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"48","PEL_DOSE_90":"24","SURVEY_TYPE":"I","sourceDate":"2026-04-22"},{"SOURCE_ROW_NUMBER":"259425","EVENT_NO":"F00D994","SURVEY_DATE":"04/22/2026","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"53","PEL_DOSE_90":"36","SURVEY_TYPE":"I","sourceDate":"2026-04-22"},{"SOURCE_ROW_NUMBER":"259431","EVENT_NO":"F02A965","SURVEY_DATE":"08/20/2025","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"20","ACT_DOSE_85":"5","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2025-08-20"},{"SOURCE_ROW_NUMBER":"259430","EVENT_NO":"F02A965","SURVEY_DATE":"08/20/2025","OCCUPATION_CD_DESC":"DISPATCHER","MACHINE_CD":"40","ACT_DOSE_85":"2","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2025-08-20"},{"SOURCE_ROW_NUMBER":"259367","EVENT_NO":"6322493","SURVEY_DATE":"11/20/2024","OCCUPATION_CD_DESC":"TIMBERMAN","MACHINE_CD":"40","ACT_DOSE_85":"38","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2024-11-20"},{"SOURCE_ROW_NUMBER":"259366","EVENT_NO":"6322493","SURVEY_DATE":"11/20/2024","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"40","ACT_DOSE_85":"34","PEL_DOSE_90":"20","SURVEY_TYPE":"I","sourceDate":"2024-11-20"},{"SOURCE_ROW_NUMBER":"259365","EVENT_NO":"6322493","SURVEY_DATE":"11/20/2024","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"40","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2024-11-20"},{"SOURCE_ROW_NUMBER":"259364","EVENT_NO":"6322493","SURVEY_DATE":"11/20/2024","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"21","PEL_DOSE_90":"68","SURVEY_TYPE":"I","sourceDate":"2024-11-20"},{"SOURCE_ROW_NUMBER":"259363","EVENT_NO":"6322493","SURVEY_DATE":"11/20/2024","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"52","PEL_DOSE_90":"36","SURVEY_TYPE":"I","sourceDate":"2024-11-20"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":71,"firstDate":"2008-04-10","lastDate":"2026-07-22","metrics":{"recentRows":34,"voidSamples":0,"maxQuartzPct":8.9,"validSamples":71,"quartzPctTotal":280.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"161039","CASSETTE_NO":"58593566","SAMPLE_DT":"07/22/2026","QUARTZ_PCT":"04.8","QUARTZ_MICROGRAMS":"25","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-22"},{"SOURCE_ROW_NUMBER":"139259","CASSETTE_NO":"58593576","SAMPLE_DT":"07/22/2026","QUARTZ_PCT":"05.8","QUARTZ_MICROGRAMS":"25","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-22"},{"SOURCE_ROW_NUMBER":"108761","CASSETTE_NO":"58594867","SAMPLE_DT":"04/22/2026","QUARTZ_PCT":"02.9","QUARTZ_MICROGRAMS":"12","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-04-22"},{"SOURCE_ROW_NUMBER":"35960","CASSETTE_NO":"58594957","SAMPLE_DT":"04/22/2026","QUARTZ_PCT":"01.6","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-04-22"},{"SOURCE_ROW_NUMBER":"35876","CASSETTE_NO":"58594805","SAMPLE_DT":"04/22/2026","QUARTZ_PCT":"06.2","QUARTZ_MICROGRAMS":"23","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-04-22"},{"SOURCE_ROW_NUMBER":"32312","CASSETTE_NO":"58594399","SAMPLE_DT":"03/18/2026","QUARTZ_PCT":"04.0","QUARTZ_MICROGRAMS":"14","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-03-18"},{"SOURCE_ROW_NUMBER":"1424","CASSETTE_NO":"58594425","SAMPLE_DT":"03/18/2026","QUARTZ_PCT":"05.6","QUARTZ_MICROGRAMS":"24","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-03-18"},{"SOURCE_ROW_NUMBER":"54726","CASSETTE_NO":"58568099","SAMPLE_DT":"10/30/2025","QUARTZ_PCT":"02.1","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-10-30"},{"SOURCE_ROW_NUMBER":"48769","CASSETTE_NO":"58568400","SAMPLE_DT":"10/30/2025","QUARTZ_PCT":"03.5","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-10-30"},{"SOURCE_ROW_NUMBER":"28967","CASSETTE_NO":"58568520","SAMPLE_DT":"08/12/2025","QUARTZ_PCT":"08.8","QUARTZ_MICROGRAMS":"16","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-08-12"},{"SOURCE_ROW_NUMBER":"168138","CASSETTE_NO":"58483384","SAMPLE_DT":"05/14/2025","QUARTZ_PCT":"08.9","QUARTZ_MICROGRAMS":"17","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-05-14"},{"SOURCE_ROW_NUMBER":"93632","CASSETTE_NO":"58504382","SAMPLE_DT":"11/20/2024","QUARTZ_PCT":"03.8","QUARTZ_MICROGRAMS":"5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2024-11-20"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":791,"firstDate":"2007-07-24","lastDate":"2026-07-16","metrics":{"ss":163,"amountDue":253111,"contested":13,"amountPaid":253111,"recentRows":248,"section104d":8,"unterminated":2,"proposedPenalty":351673},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2915660","VIOLATION_NO":"5132066","VIOLATION_ISSUE_DT":"07/16/2026","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/23/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-07-16"},{"SOURCE_ROW_NUMBER":"2915659","VIOLATION_NO":"5132065","VIOLATION_ISSUE_DT":"07/16/2026","SIG_SUB":"N","PART_SECTION":"75.333(c)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/16/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-07-16"},{"SOURCE_ROW_NUMBER":"2915658","VIOLATION_NO":"5132064","VIOLATION_ISSUE_DT":"07/14/2026","PART_SECTION":"75.1403","CIT_ORD_SAFE":"Safeguard","NO_AFFECTED":"0","TERMINATION_DT":"07/14/2026","CONTESTED_IND":"N","sourceDate":"2026-07-14"},{"SOURCE_ROW_NUMBER":"2915657","VIOLATION_NO":"5132063","VIOLATION_ISSUE_DT":"07/09/2026","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/14/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-07-09"},{"SOURCE_ROW_NUMBER":"2915656","VIOLATION_NO":"5132062","VIOLATION_ISSUE_DT":"07/09/2026","SIG_SUB":"N","PART_SECTION":"75.1731(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/14/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-07-09"},{"SOURCE_ROW_NUMBER":"2915655","VIOLATION_NO":"5132061","VIOLATION_ISSUE_DT":"07/09/2026","SIG_SUB":"N","PART_SECTION":"75.1103-8(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/09/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-07-09"},{"SOURCE_ROW_NUMBER":"2915654","VIOLATION_NO":"5132060","VIOLATION_ISSUE_DT":"07/09/2026","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/14/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-07-09"},{"SOURCE_ROW_NUMBER":"2915653","VIOLATION_NO":"5132059","VIOLATION_ISSUE_DT":"07/09/2026","SIG_SUB":"N","PART_SECTION":"75.516","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/09/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-07-09"},{"SOURCE_ROW_NUMBER":"2915652","VIOLATION_NO":"5132058","VIOLATION_ISSUE_DT":"07/09/2026","SIG_SUB":"Y","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/09/2026","PROPOSED_PENALTY":"245","AMOUNT_DUE":"245","AMOUNT_PAID":"245","CONTESTED_IND":"N","sourceDate":"2026-07-09"},{"SOURCE_ROW_NUMBER":"2915651","VIOLATION_NO":"5132057","VIOLATION_ISSUE_DT":"07/08/2026","SIG_SUB":"N","PART_SECTION":"75.604(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/08/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-07-08"},{"SOURCE_ROW_NUMBER":"2915650","VIOLATION_NO":"5132056","VIOLATION_ISSUE_DT":"07/08/2026","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/08/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-07-08"},{"SOURCE_ROW_NUMBER":"2915649","VIOLATION_NO":"5132055","VIOLATION_ISSUE_DT":"07/08/2026","SIG_SUB":"Y","PART_SECTION":"75.604(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/08/2026","PROPOSED_PENALTY":"504","AMOUNT_DUE":"504","AMOUNT_PAID":"504","CONTESTED_IND":"N","sourceDate":"2026-07-08"}]}],"safety":{"href":"/api/v1/mines/4609207/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609207/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":{"averageEmployees":21,"companyType":"Independent Producer Operator","components":[{"averageEmployees":21,"laborHours":44378,"mineType":"Underground","productionTons":121926}],"county":"Mcdowell","laborHours":44378,"mineName":"Mine No 2","mineType":"Underground","mshaId":"4609207","operatingAddress":"Hc 32 Box 588, Caretta, WV 24821","operatingCompany":"Harman Branch Mining Inc","operationType":"Mine only","productionTons":121926,"reportedRows":1,"sourceUrl":"https://www.eia.gov/coal/data/public/xls/coalpublic2024.xlsx","state":"West Virginia (Southern)","status":"Active, men working, not producing","supplyRegion":"Appalachia Central","union":"","year":2024},"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403","heading":"Other safeguards.","id":"75.1403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"[Statutory Provisions]\n\nOther safeguards adequate, in the judgment of an authorized representative of the Secretary, to minimize hazards with respect to transportation of men and materials shall be provided.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1731","heading":"Maintenance of belt conveyors and belt conveyor entries.","id":"75.1731","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1731","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Damaged rollers, or other damaged belt conveyor components, which pose a fire hazard must be immediately repaired or replaced. All other damaged rollers, or other damaged belt conveyor components, must be repaired or replaced.\n\n(b) Conveyor belts must be properly aligned to prevent the moving belt from rubbing against the structure or components.\n\n(c) Materials shall not be allowed in the belt conveyor entry where the material may contribute to a frictional heating hazard.\n\n(d) Splicing of any approved conveyor belt must maintain flame-resistant properties of the belt.\n\n[73 FR 80616, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1103-8","heading":"Automatic fire sensor and warning device systems; examination and test requirements.","id":"75.1103-8","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103-8","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Automatic fire sensor and warning device systems shall be examined at least once each shift when belts are operated as part of a production shift. A functional test of the warning signals shall be made at least once every seven days. Examination and maintenance of such systems shall be by a qualified person.\n\n(b) A record of the functional test conducted in accordance with paragraph (a) of this section shall be maintained by the operator and kept for a period of one year.\n\n(c) Sensors shall be calibrated in accordance with the manufacturer's calibration instructions at intervals not to exceed 31 days. A record of the sensor calibrations shall be maintained by the operator and kept for a period of one year.\n\n[73 FR 80615, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.516","heading":"Power wires; support.","id":"75.516","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.516","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll power wires (except trailing cables on mobile equipment, specially designed cables conducting high-voltage power to underground rectifying equipment or transformers, or bare or insulated ground and return wires) shall be supported on well-insulated insulators and shall not contact combustible material, roof, or ribs.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.604","heading":"Permanent splicing of trailing cables.","id":"75.604","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.604","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"[Statutory Provisions]\n\nWhen permanent splices in trailing cables are made, they shall be:\n\n(a) Mechanically strong with adequate electrical conductivity and flexibility;\n\n(b) Effectively insulated and sealed so as to exclude moisture; and\n\n(c) Vulcanized or otherwise treated with suitable materials to provide flame-resistant qualities and good bonding to the outer jacket.\n\n(d) Made using splice kits accepted or approved by MSHA as flame resistant.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 57 FR 61223, Dec. 23, 1992]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609207","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}