{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4609193","name":"Parker Peerless Mine","status":"Abandoned and Sealed","status_date":"2015-06-30","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Raleigh","nearest_town":"Naoma","operator_id":"P22603","operator_name":"Marfork Coal Company Inc","controller_id":"0127321","controller_name":"Alpha Metallurgical Resources Inc","district":"C04","office":"Beckley Field Office","employees":0,"latitude":37.865556,"longitude":-81.5225},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":3050},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609193","name":"Parker Peerless Mine"},"operator":{"type":"operator","id":"P22603","name":"Marfork Coal Company Inc"},"controller":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"mine","id":"4609193","name":"Parker Peerless Mine"},"validFrom":"1993-04-01","validTo":"2011-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609193|C02508|1993-04-01|2011-05-31"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22603","name":"Marfork Coal Company Inc"},"object":{"type":"mine","id":"4609193","name":"Parker Peerless Mine"},"validFrom":"2007-08-30","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609193|P22603|2007-08-30|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"P22603","name":"Marfork Coal Company Inc"},"validFrom":"2007-08-30","validTo":"2011-05-31","current":false,"derived":true,"evidenceMineId":"4609193","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609193|P22603|2007-08-30|C02508|1993-04-01|59362"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"4609193","name":"Parker Peerless Mine"},"validFrom":"2011-06-01","validTo":"2016-07-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609193|0041211|2011-06-01|2016-07-25"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P22603","name":"Marfork Coal Company Inc"},"validFrom":"2011-06-01","validTo":"2016-07-25","current":false,"derived":true,"evidenceMineId":"4609193","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609193|P22603|2007-08-30|0041211|2011-06-01|2191"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"mine","id":"4609193","name":"Parker Peerless Mine"},"validFrom":"2016-07-26","validTo":"2018-11-08","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609193|0127923|2016-07-26|2018-11-08"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"operator","id":"P22603","name":"Marfork Coal Company Inc"},"validFrom":"2016-07-26","validTo":"2018-11-08","current":false,"derived":true,"evidenceMineId":"4609193","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609193|P22603|2007-08-30|0127923|2016-07-26|25286"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"mine","id":"4609193","name":"Parker Peerless Mine"},"validFrom":"2018-11-09","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609193|0127321|2018-11-09|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"operator","id":"P22603","name":"Marfork Coal Company Inc"},"validFrom":"2018-11-09","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609193","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609193|P22603|2007-08-30|0127321|2018-11-09|24921"}}],"coverage":{"historyRecords":4,"edgeCount":9,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":40,"firstDate":"2008-05-26","lastDate":"2015-03-26","metrics":{"daysLost":865,"injuries":35,"fatalities":0,"recentRows":0,"restrictedDays":26,"contractorRecords":1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"266406","DOCUMENT_NO":"220151900017","ACCIDENT_DT":"03/26/2015","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee has been diagnosed with Occupational Pneumoconiosis. The Safety Department received notification of his diagnosis on 7/9/2015.  Employee retired December 3, 2012.","sourceDate":"2015-03-26"},{"SOURCE_ROW_NUMBER":"94164","DOCUMENT_NO":"220131560004","ACCIDENT_DT":"05/28/2013","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"An unplanned roof fall occurred outby #5 neutral entry near old #6 Belt spad 3037.  The fall was approximately 90' x 20' x 5' to 6'.  No injuries were report and no equipment was damaged.","sourceDate":"2013-05-28"},{"SOURCE_ROW_NUMBER":"150337","DOCUMENT_NO":"220140830058","ACCIDENT_DT":"05/23/2013","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (REPEATED TRAUMA)","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Superintendent","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee has been diagnosed with Occupational Bilateral Carpal Tunnel Syndrome.","sourceDate":"2013-05-23"},{"SOURCE_ROW_NUMBER":"68441","DOCUMENT_NO":"220131710047","ACCIDENT_DT":"09/18/2012","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While Employee was resetting a timber he felt pain in his right shoulder. Employee did not seek medical treatment until 9/27/12 which x-rays and MRI were taken. Employee did not miss any work but had multiple sessions of physical therapy and/or chiropractic treatment. Employee also had a steroid injection guided by x-ray done by an orthopedic surgeon.","sourceDate":"2012-09-18"},{"SOURCE_ROW_NUMBER":"4058","DOCUMENT_NO":"220120580038","ACCIDENT_DT":"02/16/2012","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"As Employee was cutting a piece of belt with a knife; the knife slipped cutting his right thigh above the knee.  Employee was treated at Raleigh General Hospital and received one (1) staple.","sourceDate":"2012-02-16"},{"SOURCE_ROW_NUMBER":"12669","DOCUMENT_NO":"220120370074","ACCIDENT_DT":"01/26/2012","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was pulling one loop of feeder cable, approximately 30ft, when nylon rope hanger broke which caused s-hook to fly backwards 20ft in the air striking the right side of Employee's bottom lip and chipped his tooth.","sourceDate":"2012-01-26"},{"SOURCE_ROW_NUMBER":"201787","DOCUMENT_NO":"220120090051","ACCIDENT_DT":"12/28/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"As Employee tripped over a jack and fell against another jack causing a laceration to his left hand.  Employee was treated at Raleigh General Hospital where he received three (3) sutures to his left hand.","sourceDate":"2011-12-28"},{"SOURCE_ROW_NUMBER":"197462","DOCUMENT_NO":"220113540034","ACCIDENT_DT":"11/15/2011","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"STEPPING OR KNEELING ON OBJECT","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"As Employee was walking he stepped on a rock which caused his right ankle to roll.  Employee was treated at Med Express and xrays were taken.","sourceDate":"2011-11-15"},{"SOURCE_ROW_NUMBER":"141673","DOCUMENT_NO":"220113070024","ACCIDENT_DT":"10/19/2011","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"As Employee was carrying a roll of curtain he tripped on a rock causing the curtain to strike the back of his neck. Employee was treated at Raleigh General Hospital. Xrays were negative but was instructed to be on restricted duty for 10 days.","sourceDate":"2011-10-19"},{"SOURCE_ROW_NUMBER":"64096","DOCUMENT_NO":"220112900019","ACCIDENT_DT":"10/10/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Utility man, Errand boy, Service truck operator","NO_INJURIES":"1","DAYS_LOST":"7","NARRATIVE":"As Employee was moving a battery lid the lid slipped and fell striking his right foot. Employee was treated at Fayette Foot and Ankle Clinic. Employee had xrays taken which were negative.","sourceDate":"2011-10-10"},{"SOURCE_ROW_NUMBER":"111328","DOCUMENT_NO":"220112840004","ACCIDENT_DT":"09/09/2011","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"As Employee was scaling top in #5R a piece of draw rock fell out between a row of bolts striking Employee on the head and neck.  Employee was treated at Raleigh General Hospital.","sourceDate":"2011-09-09"},{"SOURCE_ROW_NUMBER":"89989","DOCUMENT_NO":"220112500025","ACCIDENT_DT":"08/30/2011","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"As employee was moving continuous miner to the intersection of 5 and 6 to make repairs a piece of rock fell out between a row of bolts striking employee on the left arm. Employee was treated at the scene by EMTs and transported to Raleigh General Hospital for further evaluation. Xrays were taken and was negative but was instructed to be on restricted duty for four (4) days.","sourceDate":"2011-08-30"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2015-06-30","lastDate":"2015-06-30","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":616,"firstDate":"2008-03-27","lastDate":"2015-06-22","metrics":{"ss":169,"delinquent":616,"recentRows":0,"paidPenalty":1096009,"proposedPenalty":1243258,"currentAssessment":1096009},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1831497","VIOLATION_NO":"9056981","ISSUE_DT":"06/22/2015","CFR_STANDARD_CD":"75.1711-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"873.00","CURRENT_ASSESSMENT_AMT":"873.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-06-22"},{"SOURCE_ROW_NUMBER":"1816174","VIOLATION_NO":"9001613","ISSUE_DT":"02/20/2014","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1412.00","CURRENT_ASSESSMENT_AMT":"1412.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-02-20"},{"SOURCE_ROW_NUMBER":"1816173","VIOLATION_NO":"9001612","ISSUE_DT":"02/20/2014","CFR_STANDARD_CD":"75.364(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"687.00","CURRENT_ASSESSMENT_AMT":"687.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-02-20"},{"SOURCE_ROW_NUMBER":"1816172","VIOLATION_NO":"9001611","ISSUE_DT":"02/20/2014","CFR_STANDARD_CD":"75.335(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2161.00","CURRENT_ASSESSMENT_AMT":"2161.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-02-20"},{"SOURCE_ROW_NUMBER":"1816176","VIOLATION_NO":"9002002","ISSUE_DT":"01/23/2014","CFR_STANDARD_CD":"75.1100-2(f)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-01-23"},{"SOURCE_ROW_NUMBER":"1816175","VIOLATION_NO":"9002001","ISSUE_DT":"01/23/2014","CFR_STANDARD_CD":"75.1714-6","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"334.00","CURRENT_ASSESSMENT_AMT":"334.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-01-23"},{"SOURCE_ROW_NUMBER":"1847477","VIOLATION_NO":"7169672","ISSUE_DT":"09/23/2013","CFR_STANDARD_CD":"75.515","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"263.00","CURRENT_ASSESSMENT_AMT":"263.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-09-23"},{"SOURCE_ROW_NUMBER":"1847478","VIOLATION_NO":"9001687","ISSUE_DT":"09/18/2013","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"263.00","CURRENT_ASSESSMENT_AMT":"263.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-09-18"},{"SOURCE_ROW_NUMBER":"1847476","VIOLATION_NO":"7169671","ISSUE_DT":"09/18/2013","CFR_STANDARD_CD":"75.1714-8(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-09-18"},{"SOURCE_ROW_NUMBER":"1847453","VIOLATION_NO":"7169642","ISSUE_DT":"06/25/2013","CFR_STANDARD_CD":"75.1505(a)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1795.00","CURRENT_ASSESSMENT_AMT":"1795.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-06-25"},{"SOURCE_ROW_NUMBER":"1832225","VIOLATION_NO":"8154641","ISSUE_DT":"03/25/2013","CFR_STANDARD_CD":"47.51(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"425.00","CURRENT_ASSESSMENT_AMT":"425.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-03-25"},{"SOURCE_ROW_NUMBER":"1832224","VIOLATION_NO":"8154640","ISSUE_DT":"03/19/2013","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"334.00","CURRENT_ASSESSMENT_AMT":"334.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-03-19"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":203,"firstDate":"2011-02-10","lastDate":"2014-10-15","metrics":{"appeals":0,"decisions":203,"recentRows":0,"decisionPenalty":733933,"originalPenalty":887547},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"351532","VIOLATION_NO":"8154639","DOCKET_NO":"WEVA 2014-261","DECISION_DT":"10/15/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"18271.00","DECISION_PENALTY_AMT":"12271.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2014-10-15"},{"SOURCE_ROW_NUMBER":"102843","VIOLATION_NO":"8154635","DOCKET_NO":"WEVA 2014-261","DECISION_DT":"10/15/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"23229.00","DECISION_PENALTY_AMT":"17229.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2014-10-15"},{"SOURCE_ROW_NUMBER":"99661","VIOLATION_NO":"8154581","DOCKET_NO":"WEVA 2013-1142","DECISION_DT":"05/30/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"7578.00","DECISION_PENALTY_AMT":"5300.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2014-05-30"},{"SOURCE_ROW_NUMBER":"327156","VIOLATION_NO":"7228079","DOCKET_NO":"WEVA 2012-1234","DECISION_DT":"03/28/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"6458.00","DECISION_PENALTY_AMT":"436.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2014-03-28"},{"SOURCE_ROW_NUMBER":"344763","VIOLATION_NO":"8154634","DOCKET_NO":"WEVA 2013-978","DECISION_DT":"02/26/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":"875.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2014-02-26"},{"SOURCE_ROW_NUMBER":"98364","VIOLATION_NO":"8154636","DOCKET_NO":"WEVA 2013-978","DECISION_DT":"02/26/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"285.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2014-02-26"},{"SOURCE_ROW_NUMBER":"320000","VIOLATION_NO":"8145277","DOCKET_NO":"WEVA 2012-790","DECISION_DT":"11/13/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"25163.00","DECISION_PENALTY_AMT":"17500.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2013-11-13"},{"SOURCE_ROW_NUMBER":"319143","VIOLATION_NO":"8145279","DOCKET_NO":"WEVA 2012-662","DECISION_DT":"11/13/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2976.00","DECISION_PENALTY_AMT":"2976.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2013-11-13"},{"SOURCE_ROW_NUMBER":"318472","VIOLATION_NO":"8145278","DOCKET_NO":"WEVA 2012-662","DECISION_DT":"11/13/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"14743.00","DECISION_PENALTY_AMT":"7399.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2013-11-13"},{"SOURCE_ROW_NUMBER":"341648","VIOLATION_NO":"8154579","DOCKET_NO":"WEVA 2013-596","DECISION_DT":"09/18/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"5961.00","DECISION_PENALTY_AMT":"4000.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2013-09-18"},{"SOURCE_ROW_NUMBER":"340565","VIOLATION_NO":"8154580","DOCKET_NO":"WEVA 2013-596","DECISION_DT":"09/18/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"5961.00","DECISION_PENALTY_AMT":"2000.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2013-09-18"},{"SOURCE_ROW_NUMBER":"318474","VIOLATION_NO":"8140013","DOCKET_NO":"WEVA 2012-663","DECISION_DT":"08/19/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"5503.00","DECISION_PENALTY_AMT":"5503.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2013-08-19"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":824,"firstDate":"2008-03-31","lastDate":"2012-02-23","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":136,"validSamples":688,"maxConcentration":18.434,"concentrationTotal":536.421},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1248176","CASS_NUM":"51168740","SMP_TAKEN_DT":"2/23/2012","CONC":".174","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-02-23"},{"SOURCE_ROW_NUMBER":"1644863","CASS_NUM":"57964724","SMP_TAKEN_DT":"2/21/2012","CONC":".123","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-02-21"},{"SOURCE_ROW_NUMBER":"1631057","CASS_NUM":"57964669","SMP_TAKEN_DT":"2/21/2012","CONC":".135","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-02-21"},{"SOURCE_ROW_NUMBER":"1478511","CASS_NUM":"57964675","SMP_TAKEN_DT":"2/21/2012","CONC":".661","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-02-21"},{"SOURCE_ROW_NUMBER":"1407664","CASS_NUM":"57964704","SMP_TAKEN_DT":"2/21/2012","CONC":".399","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-02-21"},{"SOURCE_ROW_NUMBER":"1350924","CASS_NUM":"57964642","SMP_TAKEN_DT":"2/21/2012","CONC":".414","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-02-21"},{"SOURCE_ROW_NUMBER":"1287344","CASS_NUM":"57964699","SMP_TAKEN_DT":"2/21/2012","CONC":".671","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-02-21"},{"SOURCE_ROW_NUMBER":"1265468","CASS_NUM":"57964641","SMP_TAKEN_DT":"2/21/2012","CONC":".434","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-02-21"},{"SOURCE_ROW_NUMBER":"1242648","CASS_NUM":"57964710","SMP_TAKEN_DT":"2/21/2012","CONC":".567","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-02-21"},{"SOURCE_ROW_NUMBER":"1044388","CASS_NUM":"57964739","SMP_TAKEN_DT":"2/21/2012","CONC":".449","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-02-21"},{"SOURCE_ROW_NUMBER":"777192","CASS_NUM":"57964632","SMP_TAKEN_DT":"2/21/2012","CONC":".253","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-02-21"},{"SOURCE_ROW_NUMBER":"527208","CASS_NUM":"57964741","SMP_TAKEN_DT":"2/21/2012","CONC":".323","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-02-21"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":1,"firstDate":"2012-02-17","lastDate":"2012-02-17","metrics":{"linkedIssuances":1},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":203,"firstDate":"2008-04-29","lastDate":"2013-03-19","metrics":{"decisions":203,"ssChanged":108,"recentRows":0,"decisionPenalty":733933,"proposedPenalty":887547},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"428587","CITATION_NO":"8154639","CITATION_ISSUE_DT":"03/19/2013","DOCKET_NO":"WEVA 2014-261","DECISION_DT":"10/15/2014","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"18271.00","DECISION_PENALTY_AMT":"12271.00","sourceDate":"2013-03-19"},{"SOURCE_ROW_NUMBER":"147481","CITATION_NO":"8154635","CITATION_ISSUE_DT":"03/14/2013","DOCKET_NO":"WEVA 2014-261","DECISION_DT":"10/15/2014","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"23229.00","DECISION_PENALTY_AMT":"17229.00","sourceDate":"2013-03-14"},{"SOURCE_ROW_NUMBER":"142144","CITATION_NO":"8154636","CITATION_ISSUE_DT":"03/14/2013","DOCKET_NO":"WEVA 2013-978","DECISION_DT":"02/26/2014","CFR_STANDARD_CODE":"75.333(d)(3)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"285.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2013-03-14"},{"SOURCE_ROW_NUMBER":"30639","CITATION_NO":"8154634","CITATION_ISSUE_DT":"03/14/2013","DOCKET_NO":"WEVA 2013-978","DECISION_DT":"02/26/2014","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":"875.00","sourceDate":"2013-03-14"},{"SOURCE_ROW_NUMBER":"147744","CITATION_NO":"8154581","CITATION_ISSUE_DT":"12/13/2012","DOCKET_NO":"WEVA 2013-1142","DECISION_DT":"05/30/2014","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"7578.00","DECISION_PENALTY_AMT":"5300.00","sourceDate":"2012-12-13"},{"SOURCE_ROW_NUMBER":"88542","CITATION_NO":"8154580","CITATION_ISSUE_DT":"12/13/2012","DOCKET_NO":"WEVA 2013-596","DECISION_DT":"09/18/2013","CFR_STANDARD_CODE":"75.1714(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"5961.00","DECISION_PENALTY_AMT":"2000.00","sourceDate":"2012-12-13"},{"SOURCE_ROW_NUMBER":"201324","CITATION_NO":"8154579","CITATION_ISSUE_DT":"12/12/2012","DOCKET_NO":"WEVA 2013-596","DECISION_DT":"09/18/2013","CFR_STANDARD_CODE":"77.701","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"5961.00","DECISION_PENALTY_AMT":"4000.00","sourceDate":"2012-12-12"},{"SOURCE_ROW_NUMBER":"399527","CITATION_NO":"8145362","CITATION_ISSUE_DT":"06/29/2012","DOCKET_NO":"WEVA 2012-1655","DECISION_DT":"02/06/2013","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"5080.00","DECISION_PENALTY_AMT":"687.00","sourceDate":"2012-06-29"},{"SOURCE_ROW_NUMBER":"89567","CITATION_NO":"8145356","CITATION_ISSUE_DT":"06/06/2012","DOCKET_NO":"WEVA 2012-1538","DECISION_DT":"03/20/2013","CFR_STANDARD_CODE":"75.364(b)(1)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"6458.00","DECISION_PENALTY_AMT":"2161.00","sourceDate":"2012-06-06"},{"SOURCE_ROW_NUMBER":"258847","CITATION_NO":"8145352","CITATION_ISSUE_DT":"05/30/2012","DOCKET_NO":"WEVA 2012-1538","DECISION_DT":"03/20/2013","CFR_STANDARD_CODE":"75.1403","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"16867.00","DECISION_PENALTY_AMT":"7579.00","sourceDate":"2012-05-30"},{"SOURCE_ROW_NUMBER":"310657","CITATION_NO":"7228079","CITATION_ISSUE_DT":"03/27/2012","DOCKET_NO":"WEVA 2012-1234","DECISION_DT":"03/28/2014","CFR_STANDARD_CODE":"75.1200","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"6458.00","DECISION_PENALTY_AMT":"436.00","sourceDate":"2012-03-27"},{"SOURCE_ROW_NUMBER":"309390","CITATION_NO":"8140055","CITATION_ISSUE_DT":"02/15/2012","DOCKET_NO":"WEVA 2012-1079","DECISION_DT":"05/24/2013","CFR_STANDARD_CODE":"75.904","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"946.00","DECISION_PENALTY_AMT":"473.00","sourceDate":"2012-02-15"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":278,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":59,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":4,"firstDate":"2007-08-30","lastDate":"2007-08-30","metrics":{"recentRows":0,"currentOperatorTenures":4,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":40,"firstDate":"2007-12-12","lastDate":"2015-06-16","metrics":{"inspectors":111,"recentRows":0,"onSiteHours":2670,"inspectionHours":4671.5,"inspectionSamples":585},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"822275","EVENT_NO":"6295950","INSPECTION_BEGIN_DT":"06/16/2015","INSPECTION_END_DT":"06/25/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"85","SUM_TOTAL_ON_SITE_HOURS":"37","sourceDate":"2015-06-16"},{"SOURCE_ROW_NUMBER":"458683","EVENT_NO":"6297541","INSPECTION_BEGIN_DT":"04/01/2014","INSPECTION_END_DT":"04/02/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.5","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2014-04-01"},{"SOURCE_ROW_NUMBER":"747816","EVENT_NO":"6292897","INSPECTION_BEGIN_DT":"01/08/2014","INSPECTION_END_DT":"03/31/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"82","SUM_TOTAL_ON_SITE_HOURS":"39","sourceDate":"2014-01-08"},{"SOURCE_ROW_NUMBER":"235890","EVENT_NO":"6300574","INSPECTION_BEGIN_DT":"11/04/2013","INSPECTION_END_DT":"12/30/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"80.5","SUM_TOTAL_ON_SITE_HOURS":"35","sourceDate":"2013-11-04"},{"SOURCE_ROW_NUMBER":"114523","EVENT_NO":"6299704","INSPECTION_BEGIN_DT":"08/19/2013","INSPECTION_END_DT":"09/30/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"102.5","SUM_TOTAL_ON_SITE_HOURS":"45","sourceDate":"2013-08-19"},{"SOURCE_ROW_NUMBER":"451965","EVENT_NO":"6299508","INSPECTION_BEGIN_DT":"05/29/2013","INSPECTION_END_DT":"05/29/2013","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2013-05-29"},{"SOURCE_ROW_NUMBER":"536278","EVENT_NO":"6299701","INSPECTION_BEGIN_DT":"04/02/2013","INSPECTION_END_DT":"06/27/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"51.5","SUM_TOTAL_ON_SITE_HOURS":"26","sourceDate":"2013-04-02"},{"SOURCE_ROW_NUMBER":"295986","EVENT_NO":"6296121","INSPECTION_BEGIN_DT":"03/11/2013","INSPECTION_END_DT":"03/28/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"58","SUM_TOTAL_ON_SITE_HOURS":"38","sourceDate":"2013-03-11"},{"SOURCE_ROW_NUMBER":"11893","EVENT_NO":"6288382","INSPECTION_BEGIN_DT":"02/21/2013","INSPECTION_END_DT":"02/21/2013","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2013-02-21"},{"SOURCE_ROW_NUMBER":"1052616","EVENT_NO":"6296119","INSPECTION_BEGIN_DT":"12/12/2012","INSPECTION_END_DT":"12/26/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"56","SUM_TOTAL_ON_SITE_HOURS":"33","sourceDate":"2012-12-12"},{"SOURCE_ROW_NUMBER":"984604","EVENT_NO":"6292870","INSPECTION_BEGIN_DT":"07/11/2012","INSPECTION_END_DT":"09/24/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"68.5","SUM_TOTAL_ON_SITE_HOURS":"40","sourceDate":"2012-07-11"},{"SOURCE_ROW_NUMBER":"771571","EVENT_NO":"6294717","INSPECTION_BEGIN_DT":"04/02/2012","INSPECTION_END_DT":"06/13/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"84.5","SUM_TOTAL_ON_SITE_HOURS":"42.5","sourceDate":"2012-04-02"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":54,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2015-Q2":{"hours":0,"employees":0,"production":0},"2014-Q2":{"hours":0,"employees":0,"production":0},"2014-Q1":{"hours":2576,"employees":5,"production":0},"2013-Q4":{"hours":3431,"employees":8,"production":0},"2013-Q3":{"hours":3144,"employees":7,"production":0},"2013-Q2":{"hours":4334,"employees":6,"production":0},"2013-Q1":{"hours":6102,"employees":30,"production":0},"2012-Q4":{"hours":7592,"employees":16,"production":0},"2012-Q3":{"hours":7607,"employees":15,"production":0},"2012-Q2":{"hours":8080,"employees":30,"production":0},"2012-Q1":{"hours":35042,"employees":61,"production":57491},"2011-Q4":{"hours":33054,"employees":57,"production":55213}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":14,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2008":{"hours":77694,"employees":33,"production":362392},"2009":{"hours":179520,"employees":78,"production":613365},"2010":{"hours":157317,"employees":73,"production":436565},"2011":{"hours":181870,"employees":80,"production":360546},"2012":{"hours":58321,"employees":31,"production":57491},"2013":{"hours":17011,"employees":13,"production":0},"2014":{"hours":2576,"employees":5,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":56,"firstDate":"2008-04-23","lastDate":"2012-02-15","metrics":{"recentRows":0,"doseOver100":10,"actDoseTotal":4220,"pelDoseTotal":3307},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"259041","EVENT_NO":"6292864","SURVEY_DATE":"02/15/2012","OCCUPATION_CD_DESC":"CUTTING MACHINE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"038","ACT_DOSE_85":"44","PEL_DOSE_90":"27","SURVEY_TYPE":"I","sourceDate":"2012-02-15"},{"SOURCE_ROW_NUMBER":"259040","EVENT_NO":"6292864","SURVEY_DATE":"02/15/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"058","ACT_DOSE_85":"88","PEL_DOSE_90":"57","SURVEY_TYPE":"I","sourceDate":"2012-02-15"},{"SOURCE_ROW_NUMBER":"259039","EVENT_NO":"6292864","SURVEY_DATE":"02/15/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"039","ACT_DOSE_85":"79","PEL_DOSE_90":"57","SURVEY_TYPE":"I","sourceDate":"2012-02-15"},{"SOURCE_ROW_NUMBER":"259038","EVENT_NO":"6292864","SURVEY_DATE":"02/15/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"039","ACT_DOSE_85":"78","PEL_DOSE_90":"57","SURVEY_TYPE":"I","sourceDate":"2012-02-15"},{"SOURCE_ROW_NUMBER":"259037","EVENT_NO":"6292864","SURVEY_DATE":"02/15/2012","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"058","ACT_DOSE_85":"114","PEL_DOSE_90":"96","SURVEY_TYPE":"I","sourceDate":"2012-02-15"},{"SOURCE_ROW_NUMBER":"259036","EVENT_NO":"6292864","SURVEY_DATE":"02/15/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"058","ACT_DOSE_85":"45","PEL_DOSE_90":"24","SURVEY_TYPE":"I","sourceDate":"2012-02-15"},{"SOURCE_ROW_NUMBER":"259035","EVENT_NO":"6292864","SURVEY_DATE":"02/15/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"058","ACT_DOSE_85":"45","PEL_DOSE_90":"24","SURVEY_TYPE":"I","sourceDate":"2012-02-15"},{"SOURCE_ROW_NUMBER":"259034","EVENT_NO":"6292864","SURVEY_DATE":"02/15/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"039","ACT_DOSE_85":"77","PEL_DOSE_90":"55","SURVEY_TYPE":"I","sourceDate":"2012-02-15"},{"SOURCE_ROW_NUMBER":"259033","EVENT_NO":"6292864","SURVEY_DATE":"02/15/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"039","ACT_DOSE_85":"77","PEL_DOSE_90":"55","SURVEY_TYPE":"I","sourceDate":"2012-02-15"},{"SOURCE_ROW_NUMBER":"259032","EVENT_NO":"6292864","SURVEY_DATE":"02/15/2012","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"058","ACT_DOSE_85":"78","PEL_DOSE_90":"57","SURVEY_TYPE":"I","sourceDate":"2012-02-15"},{"SOURCE_ROW_NUMBER":"259031","EVENT_NO":"6292864","SURVEY_DATE":"02/15/2012","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"040","ACT_DOSE_85":"63","PEL_DOSE_90":"46","SURVEY_TYPE":"I","sourceDate":"2012-02-15"},{"SOURCE_ROW_NUMBER":"259030","EVENT_NO":"6292864","SURVEY_DATE":"02/15/2012","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"040","ACT_DOSE_85":"32","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2012-02-15"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":25,"firstDate":"2008-04-08","lastDate":"2011-06-21","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":7.7,"validSamples":25,"quartzPctTotal":140.1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"34357","CASSETTE_NO":"51101744","SAMPLE_DT":"06/21/2011","QUARTZ_PCT":"04.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-06-21"},{"SOURCE_ROW_NUMBER":"100638","CASSETTE_NO":"51107507","SAMPLE_DT":"05/31/2011","QUARTZ_PCT":"07.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-05-31"},{"SOURCE_ROW_NUMBER":"81153","CASSETTE_NO":"57883344","SAMPLE_DT":"10/22/2010","QUARTZ_PCT":"06.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-10-22"},{"SOURCE_ROW_NUMBER":"52972","CASSETTE_NO":"57883267","SAMPLE_DT":"10/20/2010","QUARTZ_PCT":"06.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-10-20"},{"SOURCE_ROW_NUMBER":"18736","CASSETTE_NO":"57883279","SAMPLE_DT":"10/20/2010","QUARTZ_PCT":"06.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-10-20"},{"SOURCE_ROW_NUMBER":"108458","CASSETTE_NO":"57832081","SAMPLE_DT":"09/17/2010","QUARTZ_PCT":"06.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-09-17"},{"SOURCE_ROW_NUMBER":"166119","CASSETTE_NO":"57831357","SAMPLE_DT":"02/25/2010","QUARTZ_PCT":"00.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-02-25"},{"SOURCE_ROW_NUMBER":"166956","CASSETTE_NO":"57831079","SAMPLE_DT":"02/08/2010","QUARTZ_PCT":"06.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-02-08"},{"SOURCE_ROW_NUMBER":"26965","CASSETTE_NO":"57831067","SAMPLE_DT":"02/08/2010","QUARTZ_PCT":"07.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-02-08"},{"SOURCE_ROW_NUMBER":"145219","CASSETTE_NO":"51048861","SAMPLE_DT":"01/29/2010","QUARTZ_PCT":"01.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-01-29"},{"SOURCE_ROW_NUMBER":"26235","CASSETTE_NO":"57831062","SAMPLE_DT":"01/06/2010","QUARTZ_PCT":"05.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-01-06"},{"SOURCE_ROW_NUMBER":"114105","CASSETTE_NO":"57830873","SAMPLE_DT":"12/01/2009","QUARTZ_PCT":"05.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-12-01"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":631,"firstDate":"2008-03-27","lastDate":"2015-06-22","metrics":{"ss":169,"amountDue":1096009,"contested":125,"amountPaid":1096009,"recentRows":0,"section104d":12,"unterminated":3,"proposedPenalty":1243258},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2913766","VIOLATION_NO":"9056981","VIOLATION_ISSUE_DT":"06/22/2015","SIG_SUB":"N","PART_SECTION":"75.1711-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/22/2015","PROPOSED_PENALTY":"873","AMOUNT_DUE":"873","AMOUNT_PAID":"873","CONTESTED_IND":"N","sourceDate":"2015-06-22"},{"SOURCE_ROW_NUMBER":"2913579","VIOLATION_NO":"9001614","VIOLATION_ISSUE_DT":"02/20/2014","PART_SECTION":"75.335(c)","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"06/25/2015","CONTESTED_IND":"N","sourceDate":"2014-02-20"},{"SOURCE_ROW_NUMBER":"2913578","VIOLATION_NO":"9001613","VIOLATION_ISSUE_DT":"02/20/2014","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"Reckless","TERMINATION_DT":"02/27/2014","PROPOSED_PENALTY":"1412","AMOUNT_DUE":"1412","AMOUNT_PAID":"1412","CONTESTED_IND":"N","sourceDate":"2014-02-20"},{"SOURCE_ROW_NUMBER":"2913577","VIOLATION_NO":"9001612","VIOLATION_ISSUE_DT":"02/20/2014","SIG_SUB":"N","PART_SECTION":"75.364(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"5","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"02/27/2014","PROPOSED_PENALTY":"687","AMOUNT_DUE":"687","AMOUNT_PAID":"687","CONTESTED_IND":"N","sourceDate":"2014-02-20"},{"SOURCE_ROW_NUMBER":"2913576","VIOLATION_NO":"9001611","VIOLATION_ISSUE_DT":"02/20/2014","SIG_SUB":"N","PART_SECTION":"75.335(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"4","NEGLIGENCE":"Reckless","PROPOSED_PENALTY":"2161","AMOUNT_DUE":"2161","AMOUNT_PAID":"2161","CONTESTED_IND":"N","sourceDate":"2014-02-20"},{"SOURCE_ROW_NUMBER":"2913581","VIOLATION_NO":"9002002","VIOLATION_ISSUE_DT":"01/23/2014","SIG_SUB":"N","PART_SECTION":"75.1100-2(f)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/23/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-01-23"},{"SOURCE_ROW_NUMBER":"2913580","VIOLATION_NO":"9002001","VIOLATION_ISSUE_DT":"01/23/2014","SIG_SUB":"N","PART_SECTION":"75.1714-6","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/23/2014","PROPOSED_PENALTY":"334","AMOUNT_DUE":"334","AMOUNT_PAID":"334","CONTESTED_IND":"N","sourceDate":"2014-01-23"},{"SOURCE_ROW_NUMBER":"2913909","VIOLATION_NO":"7169672","VIOLATION_ISSUE_DT":"09/23/2013","SIG_SUB":"N","PART_SECTION":"75.515","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/23/2013","PROPOSED_PENALTY":"263","AMOUNT_DUE":"263","AMOUNT_PAID":"263","CONTESTED_IND":"N","sourceDate":"2013-09-23"},{"SOURCE_ROW_NUMBER":"2913910","VIOLATION_NO":"9001687","VIOLATION_ISSUE_DT":"09/18/2013","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/18/2013","PROPOSED_PENALTY":"263","AMOUNT_DUE":"263","AMOUNT_PAID":"263","CONTESTED_IND":"N","sourceDate":"2013-09-18"},{"SOURCE_ROW_NUMBER":"2913908","VIOLATION_NO":"7169671","VIOLATION_ISSUE_DT":"09/18/2013","SIG_SUB":"N","PART_SECTION":"75.1714-8(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/25/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-09-18"},{"SOURCE_ROW_NUMBER":"2913733","VIOLATION_NO":"7169642","VIOLATION_ISSUE_DT":"06/25/2013","SIG_SUB":"N","PART_SECTION":"75.1505(a)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"3","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/26/2013","PROPOSED_PENALTY":"1795","AMOUNT_DUE":"1795","AMOUNT_PAID":"1795","CONTESTED_IND":"N","sourceDate":"2013-06-25"},{"SOURCE_ROW_NUMBER":"2913589","VIOLATION_NO":"8154641","VIOLATION_ISSUE_DT":"03/25/2013","SIG_SUB":"N","PART_SECTION":"47.51(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/25/2013","PROPOSED_PENALTY":"425","AMOUNT_DUE":"425","AMOUNT_PAID":"425","CONTESTED_IND":"N","sourceDate":"2013-03-25"}]}],"safety":{"href":"/api/v1/mines/4609193/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609193/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Openings of active mines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1711-3","part":"75","subchapter":"O","subpart":"R","id":"75.1711-3","citation":"30 CFR 75.1711-3","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Seal strengths, design applications, and installation.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.335","part":"75","subchapter":"O","subpart":"D","id":"75.335","citation":"30 CFR 75.335","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.364","heading":"Weekly examination.","id":"75.364","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.364","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Worked-out areas. (1) At least every 7 days, a certified person shall examine unsealed worked-out areas where no pillars have been recovered by traveling to the area of deepest penetration; measuring methane and oxygen concentrations and air quantities and making tests to determine if the air is moving in the proper direction in the area. The locations of measurement points where tests and measurements will be performed shall be included in the mine ventilation plan and shall be adequate in number and location to assure ventilation and air quality in the area. Air quantity measurements shall also be made where the air enters and leaves the worked-out area. An alternative method of evaluating the ventilation of the area may be approved in the ventilation plan.\n\n(2) At least every 7 days, a certified person shall evaluate the effectiveness of bleeder systems required by § 75.334 as follows:\n\n(i) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in its proper direction shall be made where air enters the worked-out area.\n\n(ii) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in the proper direction shall be made immediately before the air enters a return split of air.\n\n(iii) At least one entry of each set of bleeder entries used as part of a bleeder system under § 75.334 shall be traveled in its entirety. Measurements of methane and oxygen concentrations and air quantities and a test to determine if the air is moving in the proper direction shall be made at the measurement point locations specified in the mine ventilation plan to determine the effectiveness of the bleeder system.\n\n(iv) In lieu of the requirements of paragraphs (a)(2)(i) and (iii) of this section, an alternative method of evaluation may be specified in the ventilation plan provided the alternative method results in proper evaluation of the effectiveness of the bleeder system.\n\n(b) Hazardous conditions and violations of mandatory health or safety standards. At least every 7 days, an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(8) of this section shall be made by a certified person designated by the operator at the following locations:\n\n(1) In at least one entry of each intake air course, in its entirety, so that the entire air course is traveled.\n\n(2) In at least one entry of each return air course, in its entirety, so that the entire air course is traveled.\n\n(3) In each longwall or shortwall travelway in its entirety, so that the entire travelway is traveled.\n\n(4) At each seal along return and bleeder air courses and at each seal along intake air courses not examined under § 75.360(b)(5).\n\n(5) In each escapeway so that the entire escapeway is traveled.\n\n(6) On each working section not examined under § 75.360(b)(3) during the previous 7 days.\n\n(7) At each water pump not examined during a preshift examination conducted during the previous 7 days.\n\n(8) Weekly examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust; and\n\n(iv) § 75.1403—maintenance of off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) Measurements and tests. At least every 7 days, a certified person shall—\n\n(1) Determine the volume of air entering the main intakes and in each intake split;\n\n(2) Determine the volume of air and test for methane in the last open crosscut in any pair or set of developing entries or rooms, in the return of each split of air immediately before it enters the main returns, and where the air leaves the main returns; and\n\n(3) Test for methane in the return entry nearest each set of seals immediately after the air passes the seals.\n\n(d) Hazardous conditions shall be corrected immediately. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Any violation of the nine mandatory health or safety standards found during a weekly examination shall be corrected.\n\n(e) The weekly examination may be conducted at the same time as the preshift or on-shift examinations.\n\n(f) (1) The weekly examination is not required during any 7 day period in which no one enters any underground area of the mine.\n\n(2) Except for certified persons required to make examinations, no one shall enter any underground area of the mine if a weekly examination has not been completed within the previous 7 days.\n\n(g) Certification. The person making the weekly examinations shall certify by initials, date, and the time that the examination was made. Certifications and times shall appear at enough locations to show that the entire area has been examined.\n\n(h) Recordkeeping. At the completion of any shift during which a portion of a weekly examination is conducted, a record of the results of each weekly examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards found during each examination and their locations, the corrective action taken, and the results and location of air and methane measurements, shall be made. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the person making the examination or a person designated by the operator. If made by a person other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(i) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 77 FR 20715, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1714-6","heading":"Emergency tethers.","id":"75.1714-6","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-6","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"At least one tether, which is a durable rope or equivalent material designed to permit members of a mine crew to link together while evacuating the mine during an emergency, shall be provided and stored with the additional SCSRs on the fixed work location and on the mobile equipment required in §§ 75.1714-4(a)(1) and (b) of this part.\n\n[71 FR 71454, Dec. 8, 2006]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.515","heading":"Cable fittings; suitability.","id":"75.515","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.515","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nCables shall enter metal frames of motors, splice boxes, and electric compartments only through proper fittings. When insulated wires other than cables pass through metal frames, the holes shall be substantially bushed with insulated bushings.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","heading":"Reporting SCSR inventory and malfunctions; retention of SCSRs.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-8","part":"75","subchapter":"O","subpart":"R","id":"75.1714-8","citation":"30 CFR 75.1714-8","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1505","heading":"Escapeway maps.","id":"75.1505","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-P/section-75.1505","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"P","subpartHeading":"Subpart P—Mine Emergencies","text":"(a) Content and accessibility. An escapeway map shall show the designated escapeways from the working sections or the miners' work stations to the surface or the exits at the bottom of the shaft or slope, refuge alternatives, and SCSR storage locations. The escapeway map shall be posted or readily accessible for all miners—\n\n(1) In each working section;\n\n(2) In each area where mechanized mining equipment is being installed or removed;\n\n(3) At the refuge alternative; and\n\n(4) At a surface location of the mine where miners congregate, such as at the mine bulletin board, bathhouse, or waiting room.\n\n(b) Keeping maps current. All maps shall be kept up-to-date and any change in route of travel, location of doors, location of refuge alternatives, or direction of airflow shall be shown on the maps by the end of the shift on which the change is made.\n\n(c) Informing affected miners. Miners underground on a shift when any such change is made shall be notified immediately of the change and other affected miners shall be informed of the change before entering the underground areas of the mine.\n\n[71 FR 71452, Dec. 8, 2006, as amended at 73 FR 80698, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","heading":"Requirement for an MSDS.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-47/subpart-F/section-47.51","part":"47","subchapter":"H","subpart":"F","id":"47.51","citation":"30 CFR 47.51","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","partHeading":"PART 47—HAZARD COMMUNICATION (HazCom)","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609193","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}