{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4609192","name":"LEER MINE","status":"Active","status_date":"2026-08-13","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Taylor","nearest_town":"Thornton","operator_id":"0078004","operator_name":"ICG TYGART VALLEY","controller_id":"0189840","controller_name":"Core Natural Resources Inc","district":"C03","office":"Bridgeport WV Field Office","employees":487,"latitude":39.331111,"longitude":-79.958611},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":36596},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609192","name":"LEER MINE"},"operator":{"type":"operator","id":"0078004","name":"ICG TYGART VALLEY"},"controller":{"type":"controller","id":"0189840","name":"Core Natural Resources Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"0078004","name":"ICG Tygart Valley"},"object":{"type":"mine","id":"4609192","name":"LEER MINE"},"validFrom":"2007-01-23","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609192|0078004|2007-01-23|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0045307","name":"International Coal Group Inc (ICG)"},"object":{"type":"mine","id":"4609192","name":"LEER MINE"},"validFrom":"2007-01-23","validTo":"2011-06-14","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609192|0045307|2007-01-23|2011-06-14"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0045307","name":"International Coal Group Inc (ICG)"},"object":{"type":"operator","id":"0078004","name":"ICG Tygart Valley"},"validFrom":"2007-01-23","validTo":"2011-06-14","current":false,"derived":true,"evidenceMineId":"4609192","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609192|0078004|2007-01-23|0045307|2007-01-23|5390"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15561","name":"Arch Resources Inc"},"object":{"type":"mine","id":"4609192","name":"LEER MINE"},"validFrom":"2011-06-15","validTo":"2025-01-13","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609192|C15561|2011-06-15|2025-01-13"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15561","name":"Arch Resources Inc"},"object":{"type":"operator","id":"0078004","name":"ICG Tygart Valley"},"validFrom":"2011-06-15","validTo":"2025-01-13","current":false,"derived":true,"evidenceMineId":"4609192","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609192|0078004|2007-01-23|C15561|2011-06-15|96133"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0189840","name":"Core Natural Resources Inc"},"object":{"type":"mine","id":"4609192","name":"LEER MINE"},"validFrom":"2025-01-14","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609192|0189840|2025-01-14|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0189840","name":"Core Natural Resources Inc"},"object":{"type":"operator","id":"0078004","name":"ICG Tygart Valley"},"validFrom":"2025-01-14","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609192","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609192|0078004|2007-01-23|0189840|2025-01-14|40487"}}],"coverage":{"historyRecords":3,"edgeCount":7,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":139,"firstDate":"2011-04-11","lastDate":"2026-09-19","metrics":{"daysLost":6919,"injuries":112,"fatalities":3,"recentRows":57,"restrictedDays":314,"contractorRecords":21},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"16882","DOCUMENT_NO":"220262740012","ACCIDENT_DT":"09/19/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"IE was lifting a belt roller into a mantrip. It slipped out of EE's hands and EE attempted to catch it. As EE did so, EE's finger was caught between two rollers. The injury was reported after finishing midnight shift (9/20/26) Injury was not the result of a training or compliance issue.","sourceDate":"2026-09-19"},{"SOURCE_ROW_NUMBER":"253535","DOCUMENT_NO":"220262310013","ACCIDENT_DT":"08/14/2026","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A roof fall occured in the 1TG, #2 entry, at 8 Block in the intersection. The dimensions are approximately 25'x19'x14'. No injuries occurred from the incident.","sourceDate":"2026-08-14"},{"SOURCE_ROW_NUMBER":"12665","DOCUMENT_NO":"220262370024","ACCIDENT_DT":"08/12/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"IE was cleaning a track tie. The rail was sitting on mud. The mud gave way, causing the rail to drop, catching right pointer finger between the rail and the tie. Injury was not the result of a training or compliance issue.","sourceDate":"2026-08-12"},{"SOURCE_ROW_NUMBER":"38480","DOCUMENT_NO":"220262300019","ACCIDENT_DT":"08/09/2026","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"Roof fall located in the crosscuts of 1-2 and 2-3 in the #62 Block. The dimensions are approximately 185'x19'x8'. No injuries occurred from the incident.","sourceDate":"2026-08-09"},{"SOURCE_ROW_NUMBER":"42675","DOCUMENT_NO":"220262040018","ACCIDENT_DT":"07/20/2026","DEGREE_INJURY":"PERM TOT OR PERM PRTL DISABLTY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","NARRATIVE":"Employee was carrying bolter bits to the bolter when they felt a pain in their groin.","sourceDate":"2026-07-20"},{"SOURCE_ROW_NUMBER":"257878","DOCUMENT_NO":"220262020008","ACCIDENT_DT":"07/16/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","NARRATIVE":"EE was install conduit after re-entering the CM cable, when EE felt pain in EE's left bicep.","sourceDate":"2026-07-16"},{"SOURCE_ROW_NUMBER":"270662","DOCUMENT_NO":"220262020015","ACCIDENT_DT":"07/09/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"4","NARRATIVE":"Employee was walking 3 Right #3 Belt when EE felt a pain in EE's lower back on the left side.","sourceDate":"2026-07-09"},{"SOURCE_ROW_NUMBER":"64095","DOCUMENT_NO":"220261820017","ACCIDENT_DT":"06/23/2026","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"INUNDATION","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"The mine experienced a disruption in ventilation in the District 8 Ventilation System from water during sealing of District 8.","sourceDate":"2026-06-23"},{"SOURCE_ROW_NUMBER":"219139","DOCUMENT_NO":"220261540013","ACCIDENT_DT":"05/26/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","NARRATIVE":"IE was cutting a gauge rod with a guarded grinder. The grinder kicked back and struck IE above the right knee, causing a laceration. Injury was not the result of a training or compliance issue.","sourceDate":"2026-05-26"},{"SOURCE_ROW_NUMBER":"214832","DOCUMENT_NO":"220261320004","ACCIDENT_DT":"05/07/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"59","NARRATIVE":"EE was assisting in pulling rocks off the miner when EE moved between the scoop bucket and rib. The miner operator then trammed the miner backwards, hitting the scoop bucket which then caught employee between the scoop and rib.","sourceDate":"2026-05-07"},{"SOURCE_ROW_NUMBER":"128501","DOCUMENT_NO":"220261320008","ACCIDENT_DT":"05/05/2026","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"Roof fall located in #1 Entry (Return Entry) between 13 to 14 Block. The dimensions were approximately 60'x19'x8'. No injuries occurred from this incident.","sourceDate":"2026-05-05"},{"SOURCE_ROW_NUMBER":"102734","DOCUMENT_NO":"220261210016","ACCIDENT_DT":"04/26/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"LW Propman, Propman helper, Move crew if LW, Move-up man, Jacksetter, Advanceman LW helper","NO_INJURIES":"1","NARRATIVE":"Employee was kneeling on a shield when EE advanced an adjacent shield in. As shield set it lodged EE's foot between the clevis and panline.","sourceDate":"2026-04-26"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2026-08-13","lastDate":"2026-08-13","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":4156,"firstDate":"2008-10-30","lastDate":"2026-08-27","metrics":{"ss":900,"delinquent":3917,"recentRows":1094,"paidPenalty":2358060.53,"proposedPenalty":2969270,"currentAssessment":2530419},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2964452","VIOLATION_NO":"9188273","ISSUE_DT":"08/27/2026","CFR_STANDARD_CD":"75.1600-2(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"193.00","CURRENT_ASSESSMENT_AMT":"193.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-27"},{"SOURCE_ROW_NUMBER":"2964451","VIOLATION_NO":"9188272","ISSUE_DT":"08/27/2026","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"775.00","CURRENT_ASSESSMENT_AMT":"775.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-27"},{"SOURCE_ROW_NUMBER":"3003160","VIOLATION_NO":"8046849","ISSUE_DT":"08/26/2026","CFR_STANDARD_CD":"77.400(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"3184.00","CURRENT_ASSESSMENT_AMT":"3184.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"2964264","VIOLATION_NO":"9934143","ISSUE_DT":"08/25/2026","CFR_STANDARD_CD":"75.331(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"288.00","CURRENT_ASSESSMENT_AMT":"288.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-25"},{"SOURCE_ROW_NUMBER":"2970761","VIOLATION_NO":"8056009","ISSUE_DT":"08/23/2026","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"313.00","CURRENT_ASSESSMENT_AMT":"313.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-23"},{"SOURCE_ROW_NUMBER":"2970760","VIOLATION_NO":"8056008","ISSUE_DT":"08/22/2026","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1550.00","CURRENT_ASSESSMENT_AMT":"1550.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-22"},{"SOURCE_ROW_NUMBER":"3003167","VIOLATION_NO":"8046848","ISSUE_DT":"08/14/2026","CFR_STANDARD_CD":"75.1403","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2712.00","CURRENT_ASSESSMENT_AMT":"2712.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-14"},{"SOURCE_ROW_NUMBER":"3003166","VIOLATION_NO":"8046847","ISSUE_DT":"08/13/2026","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"818.00","CURRENT_ASSESSMENT_AMT":"818.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-13"},{"SOURCE_ROW_NUMBER":"3003159","VIOLATION_NO":"8046846","ISSUE_DT":"08/10/2026","CFR_STANDARD_CD":"75.1731(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-10"},{"SOURCE_ROW_NUMBER":"3003158","VIOLATION_NO":"8046845","ISSUE_DT":"08/10/2026","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1818.00","CURRENT_ASSESSMENT_AMT":"1818.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-10"},{"SOURCE_ROW_NUMBER":"3003157","VIOLATION_NO":"8046844","ISSUE_DT":"08/06/2026","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2312.00","CURRENT_ASSESSMENT_AMT":"2312.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-06"},{"SOURCE_ROW_NUMBER":"3003156","VIOLATION_NO":"8046843","ISSUE_DT":"08/06/2026","CFR_STANDARD_CD":"75.351(c)(3)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"549.00","CURRENT_ASSESSMENT_AMT":"549.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-06"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":713,"firstDate":"2012-10-05","lastDate":"2026-09-17","metrics":{"appeals":0,"decisions":699,"recentRows":77,"decisionPenalty":1117875,"originalPenalty":1559303},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"463199","VIOLATION_NO":"9935349","DOCKET_NO":"WEVA 2026-0197","DECISION_DT":"09/17/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"642.00","DECISION_PENALTY_AMT":"288.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Young","sourceDate":"2026-09-17"},{"SOURCE_ROW_NUMBER":"462701","VIOLATION_NO":"9938221","DOCKET_NO":"WEVA 2026-0197","DECISION_DT":"09/17/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"642.00","DECISION_PENALTY_AMT":"193.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Young","sourceDate":"2026-09-17"},{"SOURCE_ROW_NUMBER":"462700","VIOLATION_NO":"9938210","DOCKET_NO":"WEVA 2026-0197","DECISION_DT":"09/17/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3736.00","DECISION_PENALTY_AMT":"1007.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Young","sourceDate":"2026-09-17"},{"SOURCE_ROW_NUMBER":"462111","VIOLATION_NO":"9938222","DOCKET_NO":"WEVA 2026-0197","DECISION_DT":"09/17/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"642.00","DECISION_PENALTY_AMT":"193.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Young","sourceDate":"2026-09-17"},{"SOURCE_ROW_NUMBER":"462110","VIOLATION_NO":"9938214","DOCKET_NO":"WEVA 2026-0197","DECISION_DT":"09/17/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"288.00","DECISION_PENALTY_AMT":"288.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Young","sourceDate":"2026-09-17"},{"SOURCE_ROW_NUMBER":"462109","VIOLATION_NO":"9938213","DOCKET_NO":"WEVA 2026-0197","DECISION_DT":"09/17/2026","DECISION_TYPE_CODE_DESC":"Vacate","ORIGINAL_PENALTY_AMT":"288.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Young","sourceDate":"2026-09-17"},{"SOURCE_ROW_NUMBER":"462009","VIOLATION_NO":"9935350","DOCKET_NO":"WEVA 2026-0197","DECISION_DT":"09/17/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"818.00","DECISION_PENALTY_AMT":"818.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Young","sourceDate":"2026-09-17"},{"SOURCE_ROW_NUMBER":"168860","VIOLATION_NO":"9938225","DOCKET_NO":"WEVA 2026-0197","DECISION_DT":"09/17/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1431.00","DECISION_PENALTY_AMT":"1431.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Young","sourceDate":"2026-09-17"},{"SOURCE_ROW_NUMBER":"168450","VIOLATION_NO":"9938219","DOCKET_NO":"WEVA 2026-0197","DECISION_DT":"09/17/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1431.00","DECISION_PENALTY_AMT":"1431.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Young","sourceDate":"2026-09-17"},{"SOURCE_ROW_NUMBER":"464253","VIOLATION_NO":"9934409","DOCKET_NO":"WEVA 2026-0331","DECISION_DT":"09/16/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"432.00","DECISION_PENALTY_AMT":"432.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-09-16"},{"SOURCE_ROW_NUMBER":"464170","VIOLATION_NO":"9934404","DOCKET_NO":"WEVA 2026-0331","DECISION_DT":"09/16/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3184.00","DECISION_PENALTY_AMT":"1431.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-09-16"},{"SOURCE_ROW_NUMBER":"169765","VIOLATION_NO":"9935298","DOCKET_NO":"WEVA 2026-0331","DECISION_DT":"09/16/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1431.00","DECISION_PENALTY_AMT":"642.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-09-16"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":17908,"firstDate":"2010-03-09","lastDate":"2026-10-08","metrics":{"recentRows":9288,"cpdmSamples":14132,"voidSamples":6319,"validSamples":11589,"maxConcentration":148.409,"concentrationTotal":10563.172},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2773796","SMP_TAKEN_DT":"10/8/2026","CONC":".386","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2688629","SMP_TAKEN_DT":"10/8/2026","CONC":".752","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2773987","SMP_TAKEN_DT":"10/7/2026","CONC":".334","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2517918","SMP_TAKEN_DT":"10/7/2026","CONC":".33","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2517916","SMP_TAKEN_DT":"10/7/2026","CONC":".607","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2262454","SMP_TAKEN_DT":"10/7/2026","CONC":".536","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2176918","SMP_TAKEN_DT":"10/7/2026","CONC":".398","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2006314","SMP_TAKEN_DT":"10/7/2026","CONC":".666","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2858726","SMP_TAKEN_DT":"10/6/2026","CONC":".475","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"NON-APPROVED EQUIPMENT","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2773311","SMP_TAKEN_DT":"10/6/2026","CONC":".515","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2773271","SMP_TAKEN_DT":"10/6/2026","CONC":".409","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"NON-APPROVED EQUIPMENT","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2602922","SMP_TAKEN_DT":"10/6/2026","CONC":".591","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":181,"firstDate":"2012-03-22","lastDate":"2026-09-24","metrics":{"linkedIssuances":181},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":713,"firstDate":"2011-03-23","lastDate":"2026-07-29","metrics":{"decisions":699,"ssChanged":63,"recentRows":90,"decisionPenalty":1117875,"proposedPenalty":1715099},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"111289","CITATION_NO":"8056006","CITATION_ISSUE_DT":"07/29/2026","DOCKET_NO":"WEVA 2026-0402","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1968.00","sourceDate":"2026-07-29"},{"SOURCE_ROW_NUMBER":"223866","CITATION_NO":"9934413","CITATION_ISSUE_DT":"06/23/2026","DOCKET_NO":"WEVA 2026-0383","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1679.00","sourceDate":"2026-06-23"},{"SOURCE_ROW_NUMBER":"54471","CITATION_NO":"9934409","CITATION_ISSUE_DT":"05/27/2026","DOCKET_NO":"WEVA 2026-0331","DECISION_DT":"09/16/2026","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"432.00","DECISION_PENALTY_AMT":"432.00","sourceDate":"2026-05-27"},{"SOURCE_ROW_NUMBER":"280353","CITATION_NO":"9584954","CITATION_ISSUE_DT":"05/20/2026","DOCKET_NO":"WEVA 2026-0331","DECISION_DT":"09/16/2026","CFR_STANDARD_CODE":"75.1106-3(a)(3)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"432.00","DECISION_PENALTY_AMT":"151.00","sourceDate":"2026-05-20"},{"SOURCE_ROW_NUMBER":"167770","CITATION_NO":"9934404","CITATION_ISSUE_DT":"05/20/2026","DOCKET_NO":"WEVA 2026-0331","DECISION_DT":"09/16/2026","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3184.00","DECISION_PENALTY_AMT":"1431.00","sourceDate":"2026-05-20"},{"SOURCE_ROW_NUMBER":"450624","CITATION_NO":"9935298","CITATION_ISSUE_DT":"05/11/2026","DOCKET_NO":"WEVA 2026-0331","DECISION_DT":"09/16/2026","CFR_STANDARD_CODE":"75.1732(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1431.00","DECISION_PENALTY_AMT":"642.00","sourceDate":"2026-05-11"},{"SOURCE_ROW_NUMBER":"451789","CITATION_NO":"9586595","CITATION_ISSUE_DT":"05/05/2026","DOCKET_NO":"WEVA 2026-0331","DECISION_DT":"09/16/2026","CFR_STANDARD_CODE":"75.1722(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"642.00","DECISION_PENALTY_AMT":"151.00","sourceDate":"2026-05-05"},{"SOURCE_ROW_NUMBER":"167174","CITATION_NO":"9934397","CITATION_ISSUE_DT":"04/15/2026","DOCKET_NO":"WEVA 2026-0302","CFR_STANDARD_CODE":"75.517","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1550.00","sourceDate":"2026-04-15"},{"SOURCE_ROW_NUMBER":"167115","CITATION_NO":"9934394","CITATION_ISSUE_DT":"04/14/2026","DOCKET_NO":"WEVA 2026-0302","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"818.00","sourceDate":"2026-04-14"},{"SOURCE_ROW_NUMBER":"448837","CITATION_NO":"9935390","CITATION_ISSUE_DT":"03/23/2026","DOCKET_NO":"WEVA 2026-0263","CFR_STANDARD_CODE":"72.630(b)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"151.00","sourceDate":"2026-03-23"},{"SOURCE_ROW_NUMBER":"394587","CITATION_NO":"9935389","CITATION_ISSUE_DT":"03/23/2026","DOCKET_NO":"WEVA 2026-0402","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1679.00","sourceDate":"2026-03-23"},{"SOURCE_ROW_NUMBER":"393590","CITATION_NO":"9935388","CITATION_ISSUE_DT":"03/23/2026","DOCKET_NO":"WEVA 2026-0263","CFR_STANDARD_CODE":"75.1403-5(g)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"959.00","sourceDate":"2026-03-23"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":4524,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":21,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":1018,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":21,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"2007-01-23","lastDate":"2007-01-23","metrics":{"recentRows":0,"currentOperatorTenures":3,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":1495,"firstDate":"2008-10-29","lastDate":"2026-10-07","metrics":{"inspectors":2231,"recentRows":593,"onSiteHours":41115.25,"inspectionHours":59767,"inspectionSamples":3749},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"264292","EVENT_NO":"F02678B","INSPECTION_BEGIN_DT":"10/07/2026","INSPECTION_END_DT":"10/07/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"0","SUM_TOTAL_INSP_HOURS":"0","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"500381","EVENT_NO":"F02678A","INSPECTION_BEGIN_DT":"10/01/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16.25","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"823391","EVENT_NO":"F013FDF","INSPECTION_BEGIN_DT":"09/30/2026","INSPECTION_END_DT":"09/30/2026","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11.5","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2026-09-30"},{"SOURCE_ROW_NUMBER":"453750","EVENT_NO":"F02467B","INSPECTION_BEGIN_DT":"09/30/2026","INSPECTION_END_DT":"09/30/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2026-09-30"},{"SOURCE_ROW_NUMBER":"678446","EVENT_NO":"F0166CA","INSPECTION_BEGIN_DT":"09/29/2026","INSPECTION_END_DT":"09/29/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.25","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2026-09-29"},{"SOURCE_ROW_NUMBER":"462880","EVENT_NO":"F02467A","INSPECTION_BEGIN_DT":"09/25/2026","INSPECTION_END_DT":"09/25/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.25","SUM_TOTAL_ON_SITE_HOURS":"6.25","sourceDate":"2026-09-25"},{"SOURCE_ROW_NUMBER":"525402","EVENT_NO":"F024677","INSPECTION_BEGIN_DT":"09/18/2026","INSPECTION_END_DT":"09/18/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2026-09-18"},{"SOURCE_ROW_NUMBER":"548266","EVENT_NO":"F024675","INSPECTION_BEGIN_DT":"09/15/2026","INSPECTION_END_DT":"09/16/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.5","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2026-09-15"},{"SOURCE_ROW_NUMBER":"104330","EVENT_NO":"F024674","INSPECTION_BEGIN_DT":"09/10/2026","INSPECTION_END_DT":"09/11/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2026-09-10"},{"SOURCE_ROW_NUMBER":"685667","EVENT_NO":"F024673","INSPECTION_BEGIN_DT":"09/04/2026","INSPECTION_END_DT":"09/04/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-09-04"},{"SOURCE_ROW_NUMBER":"219546","EVENT_NO":"F024672","INSPECTION_BEGIN_DT":"08/31/2026","INSPECTION_END_DT":"09/01/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"6.25","sourceDate":"2026-08-31"},{"SOURCE_ROW_NUMBER":"839178","EVENT_NO":"F024671","INSPECTION_BEGIN_DT":"08/25/2026","INSPECTION_END_DT":"08/25/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2026-08-25"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":277,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2026-Q2":{"hours":262454,"employees":437,"production":915054},"2026-Q1":{"hours":290135,"employees":455,"production":778733},"2025-Q4":{"hours":298267,"employees":462,"production":1140206},"2025-Q3":{"hours":311698,"employees":485,"production":1377455},"2025-Q2":{"hours":326627,"employees":491,"production":1403008},"2025-Q1":{"hours":351098,"employees":567,"production":1376846},"2024-Q4":{"hours":335266,"employees":520,"production":869114},"2024-Q3":{"hours":333066,"employees":522,"production":731438},"2024-Q2":{"hours":330124,"employees":525,"production":1246258},"2024-Q1":{"hours":325288,"employees":511,"production":803332},"2023-Q4":{"hours":302758,"employees":497,"production":1297179},"2023-Q3":{"hours":303703,"employees":482,"production":1074126}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":49,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017":{"hours":1031600,"employees":439,"production":3381442},"2018":{"hours":1113142,"employees":444,"production":3444773},"2019":{"hours":1122624,"employees":427,"production":4274748},"2020":{"hours":1144218,"employees":430,"production":4185123},"2021":{"hours":1149032,"employees":463,"production":4370790},"2022":{"hours":1175619,"employees":473,"production":4041623},"2023":{"hours":1202719,"employees":482,"production":4443600},"2024":{"hours":1323744,"employees":519,"production":3650142},"2025":{"hours":1287690,"employees":502,"production":5297515},"2026":{"hours":552589,"employees":447,"production":1693787}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":600,"firstDate":"2010-08-03","lastDate":"2026-02-24","metrics":{"recentRows":183,"doseOver100":158,"actDoseTotal":47281,"pelDoseTotal":34558},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"258985","EVENT_NO":"F018E40","SURVEY_DATE":"02/24/2026","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"16","PEL_DOSE_90":"53","SURVEY_TYPE":"I","sourceDate":"2026-02-24"},{"SOURCE_ROW_NUMBER":"258984","EVENT_NO":"F018E40","SURVEY_DATE":"02/24/2026","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"62","PEL_DOSE_90":"36","SURVEY_TYPE":"I","sourceDate":"2026-02-24"},{"SOURCE_ROW_NUMBER":"258983","EVENT_NO":"F018E40","SURVEY_DATE":"02/24/2026","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"124","PEL_DOSE_90":"109","SURVEY_TYPE":"I","sourceDate":"2026-02-24"},{"SOURCE_ROW_NUMBER":"258982","EVENT_NO":"F018E40","SURVEY_DATE":"02/24/2026","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"111","PEL_DOSE_90":"98","SURVEY_TYPE":"I","sourceDate":"2026-02-24"},{"SOURCE_ROW_NUMBER":"258981","EVENT_NO":"F018E40","SURVEY_DATE":"02/24/2026","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"101","PEL_DOSE_90":"89","SURVEY_TYPE":"I","sourceDate":"2026-02-24"},{"SOURCE_ROW_NUMBER":"258980","EVENT_NO":"F018E40","SURVEY_DATE":"02/11/2026","OCCUPATION_CD_DESC":"HEADGATE OPERATOR","MACHINE_CD":"27","ACT_DOSE_85":"63","PEL_DOSE_90":"40","SURVEY_TYPE":"I","sourceDate":"2026-02-11"},{"SOURCE_ROW_NUMBER":"258979","EVENT_NO":"F018E40","SURVEY_DATE":"02/11/2026","OCCUPATION_CD_DESC":"JACK SETTER (LONGWALL)","MACHINE_CD":"40","ACT_DOSE_85":"46","PEL_DOSE_90":"24","SURVEY_TYPE":"I","sourceDate":"2026-02-11"},{"SOURCE_ROW_NUMBER":"258978","EVENT_NO":"F018E40","SURVEY_DATE":"02/11/2026","OCCUPATION_CD_DESC":"JACK SETTER (LONGWALL)","MACHINE_CD":"40","ACT_DOSE_85":"61","PEL_DOSE_90":"38","SURVEY_TYPE":"I","sourceDate":"2026-02-11"},{"SOURCE_ROW_NUMBER":"258977","EVENT_NO":"F018E40","SURVEY_DATE":"02/11/2026","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","ACT_DOSE_85":"26","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2026-02-11"},{"SOURCE_ROW_NUMBER":"258976","EVENT_NO":"F018E40","SURVEY_DATE":"02/11/2026","OCCUPATION_CD_DESC":"LONGWALL OPERATOR (HEADGATE SIDE)","MACHINE_CD":"27","ACT_DOSE_85":"77","PEL_DOSE_90":"55","SURVEY_TYPE":"I","sourceDate":"2026-02-11"},{"SOURCE_ROW_NUMBER":"258975","EVENT_NO":"F0123CC","SURVEY_DATE":"11/19/2025","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"28","PEL_DOSE_90":"14","SURVEY_TYPE":"I","sourceDate":"2025-11-19"},{"SOURCE_ROW_NUMBER":"258974","EVENT_NO":"F0123CC","SURVEY_DATE":"11/19/2025","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"34","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2025-11-19"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":605,"firstDate":"2010-07-21","lastDate":"2026-09-01","metrics":{"recentRows":283,"voidSamples":31,"maxQuartzPct":26.5,"validSamples":574,"quartzPctTotal":2209.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"134371","CASSETTE_NO":"58601200","SAMPLE_DT":"09/01/2026","QUARTZ_PCT":"01.0","QUARTZ_MICROGRAMS":"10","OCC_CODE_DESC":"JACK SETTER (LONGWALL)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"133465","CASSETTE_NO":"58600732","SAMPLE_DT":"09/01/2026","QUARTZ_PCT":"00.6","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"MECHANIC","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"52410","CASSETTE_NO":"58600744","SAMPLE_DT":"09/01/2026","QUARTZ_PCT":"01.6","QUARTZ_MICROGRAMS":"16","OCC_CODE_DESC":"LONGWALL OPERATOR (HEADGATE SIDE)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"47983","CASSETTE_NO":"58601124","SAMPLE_DT":"09/01/2026","QUARTZ_MICROGRAMS":"0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"INTAKE AIR","VOID_CD_DESC":"INVALID SAMPLE TYPE","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"156104","CASSETTE_NO":"58601094","SAMPLE_DT":"08/27/2026","QUARTZ_PCT":"02.2","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-27"},{"SOURCE_ROW_NUMBER":"108011","CASSETTE_NO":"58601098","SAMPLE_DT":"08/27/2026","QUARTZ_PCT":"00.7","QUARTZ_MICROGRAMS":"1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"INTAKE AIR","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-27"},{"SOURCE_ROW_NUMBER":"58023","CASSETTE_NO":"58601312","SAMPLE_DT":"08/27/2026","QUARTZ_PCT":"05.3","QUARTZ_MICROGRAMS":"9","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-27"},{"SOURCE_ROW_NUMBER":"123849","CASSETTE_NO":"58600731","SAMPLE_DT":"08/07/2026","QUARTZ_PCT":"04.3","QUARTZ_MICROGRAMS":"21","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-07"},{"SOURCE_ROW_NUMBER":"47705","CASSETTE_NO":"58601222","SAMPLE_DT":"08/07/2026","QUARTZ_PCT":"04.9","QUARTZ_MICROGRAMS":"24","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-07"},{"SOURCE_ROW_NUMBER":"18931","CASSETTE_NO":"58600746","SAMPLE_DT":"08/07/2026","QUARTZ_PCT":"00.6","QUARTZ_MICROGRAMS":"1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"INTAKE AIR","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-07"},{"SOURCE_ROW_NUMBER":"167331","CASSETTE_NO":"58599637","SAMPLE_DT":"07/22/2026","QUARTZ_PCT":"01.7","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-22"},{"SOURCE_ROW_NUMBER":"163548","CASSETTE_NO":"58599654","SAMPLE_DT":"07/22/2026","QUARTZ_PCT":"01.2","QUARTZ_MICROGRAMS":"5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-22"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":4213,"firstDate":"2008-10-30","lastDate":"2026-10-07","metrics":{"ss":901,"amountDue":2530419,"contested":0,"amountPaid":2358060.53,"recentRows":1119,"section104d":11,"unterminated":3,"proposedPenalty":2969270},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2913113","VIOLATION_NO":"9939477","VIOLATION_ISSUE_DT":"10/07/2026","SIG_SUB":"N","PART_SECTION":"75.333(d)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","CONTESTED_IND":"N","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2912406","VIOLATION_NO":"8046855","VIOLATION_ISSUE_DT":"09/18/2026","SIG_SUB":"N","PART_SECTION":"75.1403-6(b)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/18/2026","CONTESTED_IND":"N","sourceDate":"2026-09-18"},{"SOURCE_ROW_NUMBER":"2912394","VIOLATION_NO":"8046854","VIOLATION_ISSUE_DT":"09/16/2026","SIG_SUB":"N","PART_SECTION":"75.363(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/18/2026","CONTESTED_IND":"N","sourceDate":"2026-09-16"},{"SOURCE_ROW_NUMBER":"2912393","VIOLATION_NO":"8046853","VIOLATION_ISSUE_DT":"09/16/2026","SIG_SUB":"N","PART_SECTION":"75.1403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/16/2026","CONTESTED_IND":"N","sourceDate":"2026-09-16"},{"SOURCE_ROW_NUMBER":"2911747","VIOLATION_NO":"8046852","VIOLATION_ISSUE_DT":"09/10/2026","SIG_SUB":"N","PART_SECTION":"75.1403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/10/2026","CONTESTED_IND":"N","sourceDate":"2026-09-10"},{"SOURCE_ROW_NUMBER":"2911753","VIOLATION_NO":"9930789","VIOLATION_ISSUE_DT":"09/09/2026","SIG_SUB":"N","PART_SECTION":"75.1002(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/09/2026","CONTESTED_IND":"N","sourceDate":"2026-09-09"},{"SOURCE_ROW_NUMBER":"2911752","VIOLATION_NO":"9188279","VIOLATION_ISSUE_DT":"09/09/2026","SIG_SUB":"N","PART_SECTION":"75.1002(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/09/2026","CONTESTED_IND":"N","sourceDate":"2026-09-09"},{"SOURCE_ROW_NUMBER":"2911751","VIOLATION_NO":"9188278","VIOLATION_ISSUE_DT":"09/09/2026","SIG_SUB":"N","PART_SECTION":"75.1002(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/09/2026","CONTESTED_IND":"N","sourceDate":"2026-09-09"},{"SOURCE_ROW_NUMBER":"2911750","VIOLATION_NO":"9188277","VIOLATION_ISSUE_DT":"09/09/2026","SIG_SUB":"N","PART_SECTION":"75.1107-16-b","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/09/2026","CONTESTED_IND":"N","sourceDate":"2026-09-09"},{"SOURCE_ROW_NUMBER":"2911749","VIOLATION_NO":"9188276","VIOLATION_ISSUE_DT":"09/09/2026","SIG_SUB":"N","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/09/2026","CONTESTED_IND":"N","sourceDate":"2026-09-09"},{"SOURCE_ROW_NUMBER":"2912354","VIOLATION_NO":"8046851","VIOLATION_ISSUE_DT":"09/04/2026","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/05/2026","CONTESTED_IND":"N","sourceDate":"2026-09-04"},{"SOURCE_ROW_NUMBER":"2912111","VIOLATION_NO":"9188273","VIOLATION_ISSUE_DT":"08/27/2026","SIG_SUB":"N","PART_SECTION":"75.1600-2(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/01/2026","PROPOSED_PENALTY":"193","AMOUNT_DUE":"193","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-08-27"}]}],"safety":{"href":"/api/v1/mines/4609192/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609192/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":{"averageEmployees":520,"companyType":"Operating Subsidiary","components":[{"averageEmployees":520,"laborHours":1323744,"mineType":"Underground","productionTons":3650142}],"county":"Taylor","laborHours":1323744,"mineName":"Leer Mine","mineType":"Underground","mshaId":"4609192","operatingAddress":"1200 Tygart Drive, Grafton, WV 26354","operatingCompany":"Aci Tygart Valley","operationType":"Mine only","productionTons":3650142,"reportedRows":1,"sourceUrl":"https://www.eia.gov/coal/data/public/xls/coalpublic2024.xlsx","state":"West Virginia (Northern)","status":"Active","supplyRegion":"Appalachia Northern","union":"","year":2024},"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403-6","heading":"Criteria—Self-propelled personnel carriers.","id":"75.1403-6","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403-6","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"(a) Each self-propelled personnel carrier should:\n\n(1) Be provided with an audible warning device;\n\n(2) Be provided with a sealed-beam headlight, or its equivalent, on each end;\n\n(3) Be provided with reflectors on both ends and sides.\n\n(b) In addition, each track-mounted self-propelled personnel carrier should:\n\n(1) Be provided with a suitable lifting jack and bar, which shall be secured or carried in a tool compartment;\n\n(2) Be equipped with 2 separate and independent braking systems properly installed and well maintained;\n\n(3) Be equipped with properly installed and well-maintained sanding devices, except that personnel carriers (jitneys), which transport not more than 5 men, need not be equipped with such sanding device;\n\n(4) If an open type, be equipped with guards of sufficient strength and height to prevent personnel from being thrown from such carriers.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.363","heading":"Hazardous conditions and violations of mandatory health or safety standards; posting, correcting, and recording.","id":"75.363","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.363","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Any hazardous condition found by the mine foreman or equivalent mine official, assistant mine foreman or equivalent mine official, or other certified persons designated by the operator for the purposes of conducting examinations under this subpart D, shall be posted with a conspicuous danger sign where anyone entering the areas would pass. A hazardous condition shall be corrected immediately or the area shall remain posted until the hazardous condition is corrected. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Only persons designated by the operator to correct or evaluate the hazardous condition may enter the posted area. Any violation of a mandatory health or safety standard found during a preshift, supplemental, on-shift, or weekly examination shall be corrected.\n\n(b) A record shall be made of any hazardous condition and any violation of the nine mandatory health or safety standards found by the mine examiner. This record shall be kept in a book maintained for this purpose on the surface at the mine. The record shall be made by the completion of the shift on which the hazardous condition or violation of the nine mandatory health or safety standards is found and shall include the nature and location of the hazardous condition or violation and the corrective action taken. This record shall not be required for shifts when no hazardous conditions or violations of the nine mandatory health or safety standards are found.\n\n(c) The record shall be made by the certified person who conducted the examination or a person designated by the operator. If made by a person other than the certified person, the certified person shall verify the record by initials and date by or at the end of the shift for which the examination was made. Records shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The record shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(d) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(e) Review of citations and orders. The mine operator shall review with mine examiners on a quarterly basis citations and orders issued in areas where preshift, supplemental, on-shift, and weekly examinations are required.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 26442, May 28, 1996; 77 FR 20715, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403","heading":"Other safeguards.","id":"75.1403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"[Statutory Provisions]\n\nOther safeguards adequate, in the judgment of an authorized representative of the Secretary, to minimize hazards with respect to transportation of men and materials shall be provided.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1002","heading":"Installation of electric equipment and conductors; permissibility.","id":"75.1002","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-K/section-75.1002","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"K","subpartHeading":"Subpart K—Trolley Wires and Trolley Feeder Wires","text":"(a) Electric equipment must be permissible and maintained in a permissible condition when such equipment is located within 150 feet of pillar workings or longwall faces.\n\n(b) Electric conductors and cables installed in or in by the last open crosscut or within 150 feet of pillar workings or longwall faces must be—\n\n(1) Shielded high-voltage cables supplying power to permissible longwall equipment;\n\n(2) Interconnecting conductors and cables of permissible longwall equipment;\n\n(3) Conductors and cables of intrinsically safe circuits; and\n\n(4) Cables and conductors supplying power to low- and medium-voltage permissible equipment.\n\n(5) Shielded high-voltage cables supplying power to permissible continuous mining machines.\n\n[67 FR 11004, Mar. 11, 2002, as amended at 75 FR 17553, Apr. 6, 2010]","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-16","heading":"Inspection of fire suppression devices.","id":"75.1107-16","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-16","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) All fire suppression devices shall be visually inspected at least once each week by a person qualified to make such inspections.\n\n(b) Each fire suppression device shall be tested and maintained in accordance with the requirements specified in the appropriate National Fire Code listed as follows for the type and kind of device used:\n\nNational Fire Code No. 11A “High Expansion Foam Systems” (NFPA No. 11A—1970). National Fire Code No. 13A “Care and Maintenance of Sprinkler Systems” (NFPA No. 13A—1971). National Fire Code No. 15 “Water Spray Fixed Systems for Fire Protection” (NFPA No. 15—1969). National Fire Code No. 17 “Dry Chemical Extinguishing Systems” (NFPA No. 17—1969). National Fire Code No. 72A “Local Protective Signaling Systems” (NFPA No. 72A—1967). National Fire Code No. 198 “Care of Fire Hose” (NFPA No. 198—1969).\n\n(c) A record of the inspections required by this section shall be maintained by the operator. The record of the weekly inspections may be maintained at an appropriate location by each fire suppression device.\n\n[37 FR 15304, July 29, 1972, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.403","heading":"Maintenance of incombustible content of rock dust.","id":"75.403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 80 percent. Where methane is present in any ventilating current, the percent of incombustible content of such combined dust shall be increased 0.4 percent for each 0.1 percent of methane.\n\n[75 FR 57857, Sept. 23, 2010; 76 FR 35978, June 21, 2011]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1600-2","heading":"Communication facilities; working sections; installation and maintenance requirements; audible or visual alarms.","id":"75.1600-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-Q/section-75.1600-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Communications","text":"(a) Telephones or equivalent two-way communication facilities provided at each working section shall be located not more than 500 feet outby the last open crosscut and not more than 800 feet from the farthest point of penetration of the working places on such section.\n\n(b) The incoming communication signal shall activate an audible alarm, distinguishable from the surrounding noise level, or a visual alarm that can be seen by a miner regularly employed on the working section.\n\n(c) If a communication system other than telephones is used and its operation depends entirely upon power from the mine electric system, means shall be provided to permit continued communication in the event the mine electric power fails or is cut off; provided, however, that where trolley phones and telephones are both used, an alternate source of power for the trolley phone system is not required.\n\n(d) Trolley phones connected to the trolley wire shall be grounded in accordance with Subpart H of this part.\n\n(e) Telephones or equivalent two-way communication facilities shall be maintained in good operating condition at all times. In the event of any failure in the system that results in loss of communication, repairs shall be started immediately, and the system restored to operating condition as soon as possible.\n\n[38 FR 29999, Oct. 31, 1973]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609192","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}