{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4609152","name":"Black Oak Mine","status":"NonProducing","status_date":"2020-11-12","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Boone","nearest_town":"Wharton","operator_id":"0141655","operator_name":"Rockwell Mining LLC","controller_id":"0158381","controller_name":"Sev.en Global Investments a.s.","district":"C04","office":"Madison WV Field Office","employees":1,"latitude":37.810833,"longitude":-81.566667},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":19390},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609152","name":"Black Oak Mine"},"operator":{"type":"operator","id":"0141655","name":"Rockwell Mining LLC"},"controller":{"type":"controller","id":"0158381","name":"Sev.en Global Investments a.s."},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13737","name":"Long Branch Energy Corporation"},"object":{"type":"mine","id":"4609152","name":"Black Oak Mine"},"validFrom":"1989-03-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609152|C13737|1989-03-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"mine","id":"4609152","name":"Black Oak Mine"},"validFrom":"1998-03-26","validTo":"2007-10-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609152|C15833|1998-03-26|2007-10-30"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24184","name":"Eastern Associated Coal LLC"},"object":{"type":"mine","id":"4609152","name":"Black Oak Mine"},"validFrom":"2006-04-13","validTo":"2007-05-20","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609152|P24184|2006-04-13|2007-05-20"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"operator","id":"P24184","name":"Eastern Associated Coal LLC"},"validFrom":"2006-04-13","validTo":"2007-05-20","current":false,"derived":true,"evidenceMineId":"4609152","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609152|P24184|2006-04-13|C15833|1998-03-26|96934"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P20124","name":"Long Branch Energy"},"object":{"type":"mine","id":"4609152","name":"Black Oak Mine"},"validFrom":"2007-05-21","validTo":"2008-06-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609152|P20124|2007-05-21|2008-06-30"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13737","name":"Long Branch Energy Corporation"},"object":{"type":"operator","id":"P20124","name":"Long Branch Energy"},"validFrom":"2007-05-21","validTo":"2008-06-30","current":false,"derived":true,"evidenceMineId":"4609152","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609152|P20124|2007-05-21|C13737|1989-03-01|90999"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0071611","name":"Patriot Coal Corporation"},"object":{"type":"mine","id":"4609152","name":"Black Oak Mine"},"validFrom":"2007-10-31","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609152|0071611|2007-10-31|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0071611","name":"Patriot Coal Corporation"},"object":{"type":"operator","id":"P24184","name":"Eastern Associated Coal LLC"},"validFrom":"2007-10-31","validTo":"2007-05-20","current":false,"derived":true,"evidenceMineId":"4609152","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609152|P24184|2006-04-13|0071611|2007-10-31|10323"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24184","name":"Eastern Associated Coal LLC"},"object":{"type":"mine","id":"4609152","name":"Black Oak Mine"},"validFrom":"2008-07-01","validTo":"2015-10-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609152|P24184|2008-07-01|2015-10-25"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0071611","name":"Patriot Coal Corporation"},"object":{"type":"operator","id":"P24184","name":"Eastern Associated Coal LLC"},"validFrom":"2008-07-01","validTo":"2015-10-25","current":false,"derived":true,"evidenceMineId":"4609152","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609152|P24184|2008-07-01|0071611|2007-10-31|10324"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"operator","id":"P24184","name":"Eastern Associated Coal LLC"},"validFrom":"2008-07-01","validTo":"2007-10-30","current":false,"derived":true,"evidenceMineId":"4609152","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609152|P24184|2008-07-01|C15833|1998-03-26|96935"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0141655","name":"Rockwell Mining LLC"},"object":{"type":"mine","id":"4609152","name":"Black Oak Mine"},"validFrom":"2015-10-26","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609152|0141655|2015-10-26|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0109461","name":"Blackhawk Mining LLC"},"object":{"type":"mine","id":"4609152","name":"Black Oak Mine"},"validFrom":"2015-10-26","validTo":"2020-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609152|0109461|2015-10-26|2020-05-31"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0109461","name":"Blackhawk Mining LLC"},"object":{"type":"operator","id":"0141655","name":"Rockwell Mining LLC"},"validFrom":"2015-10-26","validTo":"2020-05-31","current":false,"derived":true,"evidenceMineId":"4609152","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609152|0141655|2015-10-26|0109461|2015-10-26|19928"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0158381","name":"Sev.en Global Investments a.s."},"object":{"type":"mine","id":"4609152","name":"Black Oak Mine"},"validFrom":"2020-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609152|0158381|2020-06-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0158381","name":"Sev.en Global Investments a.s."},"object":{"type":"operator","id":"0141655","name":"Rockwell Mining LLC"},"validFrom":"2020-06-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609152","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609152|0141655|2015-10-26|0158381|2020-06-01|32866"}}],"coverage":{"historyRecords":7,"edgeCount":16,"intervalAnomalies":2,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":198,"firstDate":"2007-10-26","lastDate":"2020-10-26","metrics":{"daysLost":11003,"injuries":166,"fatalities":0,"recentRows":0,"restrictedDays":374,"contractorRecords":10},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"8330","DOCUMENT_NO":"220203030023","ACCIDENT_DT":"10/26/2020","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"11","NARRATIVE":"Employee states that while riding outside on the #4 mantrip that the mantrip spread the track at bk7 on 9c.  When the mantrip did this, the employee stated that EE's back hit the metal seat causing pain in the lower back and rib cage.","sourceDate":"2020-10-26"},{"SOURCE_ROW_NUMBER":"219129","DOCUMENT_NO":"220203030015","ACCIDENT_DT":"10/20/2020","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Dispatcher","NO_INJURIES":"1","DAYS_LOST":"17","NARRATIVE":"Employee stated that they went outside to get a case of drinking water to put in the meeting room. They lifted the case of water to set it on the table when they herd and felt a popping in the right shoulder.","sourceDate":"2020-10-20"},{"SOURCE_ROW_NUMBER":"106912","DOCUMENT_NO":"220202760009","ACCIDENT_DT":"09/25/2020","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"105","NARRATIVE":"Witness stated that they, and injured employee, were in the process of leveling the belt structure on the 3A belt when a piece of rock dislodged from the roof striking injured employee on top of the head and right shoulder.","sourceDate":"2020-09-25"},{"SOURCE_ROW_NUMBER":"167480","DOCUMENT_NO":"220202660022","ACCIDENT_DT":"05/20/2020","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"69","NARRATIVE":"Employee stated that EE was walking beside the 222 cm when EE saw a piece of the rib falling. EE stated that EE tried to get out of the way but could not and the rib fell striking EE on the left leg and pushed EE into the operator side of the cm. The rock measured 2' x 2' x 1' thick.","sourceDate":"2020-05-20"},{"SOURCE_ROW_NUMBER":"240667","DOCUMENT_NO":"220201270020","ACCIDENT_DT":"04/24/2020","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"14","NARRATIVE":"Employee stated that EE was attempting to get a can of hydraulic oil from the oil sled. The cans were stacked 3 high, when EE pulled the top can off a second can fell from the 2nd row landing on the side of EE's right foot resulting in a fractured little toe.","sourceDate":"2020-04-24"},{"SOURCE_ROW_NUMBER":"262217","DOCUMENT_NO":"220193020004","ACCIDENT_DT":"10/23/2019","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"An unintentional roof fall occurred above the anchorage point of permanent roof support in the active workings of the # 1 Section, at the intersection of the #2 entry. (Survey Station 6847)","sourceDate":"2019-10-23"},{"SOURCE_ROW_NUMBER":"214824","DOCUMENT_NO":"220192610021","ACCIDENT_DT":"09/13/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"234","NARRATIVE":"Employee stated employee was traveling the in #6 entry just outby the section power center.  Employee stated employee walked over a small ledge in the mine floor, and hyperextended right leg, causing employee to fall to the ground injuring right knee.","sourceDate":"2019-09-13"},{"SOURCE_ROW_NUMBER":"223338","DOCUMENT_NO":"220192480012","ACCIDENT_DT":"08/27/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Bodily reaction, NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"Employee was installing a fly board in the #3 Entry on 1 section.  Employee stated they twisted their body away from the machine, and when they took a step, they felt pain in the left calf.","sourceDate":"2019-08-27"},{"SOURCE_ROW_NUMBER":"77159","DOCUMENT_NO":"220192380030","ACCIDENT_DT":"08/25/2019","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"An unintentional fall of the mine roof was found at 223 BRK (survey station: 5326) on 08-25-2019 at 08:35 PM.  A pre-shift examiner traveling the #4 (track) entry when EE found the fall.  The exact time of the fall is unknown.  The fall was reported 18' W x 34' L x 8' thick, from the intersection of the #4 entry, continuing over into the crosscut between the #4 and #3 entries.","sourceDate":"2019-08-25"},{"SOURCE_ROW_NUMBER":"25646","DOCUMENT_NO":"220192310003","ACCIDENT_DT":"08/09/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Section foreman, Bullgang foreman, Labor foreman, Leadman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"7","NARRATIVE":"Employee stated EE was pulling C/M cable in the #7 entry when EE felt a sharp burning pain in EE's lower back. Employee continued to work the remainder of the shift. On EE's way outside, the employee stated the pain got worse. EE went to the bathhouse after getting outside, and then returned to the mine office to report the incident before leaving mine property.","sourceDate":"2019-08-09"},{"SOURCE_ROW_NUMBER":"145878","DOCUMENT_NO":"220192200028","ACCIDENT_DT":"07/30/2019","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A fall was discovered by EE on the evening shift on 07/30/2019. The fall was located at brk 28 #6 entry 100' inby spad 1231 on Beltway mains. The fall was cribbed and dangered off called into the hot line. The fall was 0 to 2' thick 14' wide and 40' long.","sourceDate":"2019-07-30"},{"SOURCE_ROW_NUMBER":"34155","DOCUMENT_NO":"220192060089","ACCIDENT_DT":"07/23/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Drill helper","NO_INJURIES":"1","DAYS_LOST":"170","NARRATIVE":"Footing got stuck in mud carrying a drill reamer.  Fell due to feet stuck in mud and injured lower back.","sourceDate":"2019-07-23"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2020-11-12","lastDate":"2020-11-12","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":2892,"firstDate":"2007-07-03","lastDate":"2023-03-21","metrics":{"ss":753,"delinquent":2819,"recentRows":14,"paidPenalty":2624989.18,"proposedPenalty":3922570,"currentAssessment":2705387.75},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1921911","VIOLATION_NO":"9552571","ISSUE_DT":"03/21/2023","CFR_STANDARD_CD":"77.208(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"252.00","CURRENT_ASSESSMENT_AMT":"252.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-03-21"},{"SOURCE_ROW_NUMBER":"1921910","VIOLATION_NO":"9552570","ISSUE_DT":"03/21/2023","CFR_STANDARD_CD":"77.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"143.00","CURRENT_ASSESSMENT_AMT":"143.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-03-21"},{"SOURCE_ROW_NUMBER":"1921909","VIOLATION_NO":"9552569","ISSUE_DT":"03/21/2023","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"143.00","CURRENT_ASSESSMENT_AMT":"143.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-03-21"},{"SOURCE_ROW_NUMBER":"1921908","VIOLATION_NO":"9552568","ISSUE_DT":"03/21/2023","CFR_STANDARD_CD":"75.1712-3(c)(2)(iv)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"143.00","CURRENT_ASSESSMENT_AMT":"143.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-03-21"},{"SOURCE_ROW_NUMBER":"1921907","VIOLATION_NO":"9552567","ISSUE_DT":"03/21/2023","CFR_STANDARD_CD":"75.1712","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"376.00","CURRENT_ASSESSMENT_AMT":"376.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-03-21"},{"SOURCE_ROW_NUMBER":"1904291","VIOLATION_NO":"9246700","ISSUE_DT":"03/03/2021","CFR_STANDARD_CD":"75.364(b)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"729.00","CURRENT_ASSESSMENT_AMT":"729.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-03-03"},{"SOURCE_ROW_NUMBER":"1904290","VIOLATION_NO":"9246699","ISSUE_DT":"03/02/2021","CFR_STANDARD_CD":"75.364(b)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"220.00","CURRENT_ASSESSMENT_AMT":"220.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-03-02"},{"SOURCE_ROW_NUMBER":"1904289","VIOLATION_NO":"9246698","ISSUE_DT":"02/16/2021","CFR_STANDARD_CD":"75.1107-4(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"416.00","CURRENT_ASSESSMENT_AMT":"416.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-02-16"},{"SOURCE_ROW_NUMBER":"1904288","VIOLATION_NO":"9246697","ISSUE_DT":"02/16/2021","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1624.00","CURRENT_ASSESSMENT_AMT":"1624.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-02-16"},{"SOURCE_ROW_NUMBER":"1904287","VIOLATION_NO":"9246696","ISSUE_DT":"02/09/2021","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1500.00","CURRENT_ASSESSMENT_AMT":"1500.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-02-09"},{"SOURCE_ROW_NUMBER":"1904286","VIOLATION_NO":"9246695","ISSUE_DT":"01/20/2021","CFR_STANDARD_CD":"75.1202-1(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"125.00","CURRENT_ASSESSMENT_AMT":"125.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-01-20"},{"SOURCE_ROW_NUMBER":"1904285","VIOLATION_NO":"9246694","ISSUE_DT":"01/13/2021","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1278.00","CURRENT_ASSESSMENT_AMT":"1278.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2021-01-13"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":2025,"firstDate":"2008-07-17","lastDate":"2021-12-06","metrics":{"appeals":0,"decisions":2025,"recentRows":210,"decisionPenalty":2319442.75,"originalPenalty":3555959},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"428385","VIOLATION_NO":"9249455","DOCKET_NO":"WEVA 2021-0392","DECISION_DT":"12/06/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"6331.00","DECISION_PENALTY_AMT":"3305.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2021-12-06"},{"SOURCE_ROW_NUMBER":"428384","VIOLATION_NO":"9249453","DOCKET_NO":"WEVA 2021-0392","DECISION_DT":"12/06/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1006.00","DECISION_PENALTY_AMT":"1006.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2021-12-06"},{"SOURCE_ROW_NUMBER":"426891","VIOLATION_NO":"9249468","DOCKET_NO":"WEVA 2021-0392","DECISION_DT":"12/06/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"6858.00","DECISION_PENALTY_AMT":"3561.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2021-12-06"},{"SOURCE_ROW_NUMBER":"426890","VIOLATION_NO":"9249454","DOCKET_NO":"WEVA 2021-0392","DECISION_DT":"12/06/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"6858.00","DECISION_PENALTY_AMT":"3561.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2021-12-06"},{"SOURCE_ROW_NUMBER":"426333","VIOLATION_NO":"9249466","DOCKET_NO":"WEVA 2021-0392","DECISION_DT":"12/06/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"8048.00","DECISION_PENALTY_AMT":"1041.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2021-12-06"},{"SOURCE_ROW_NUMBER":"426332","VIOLATION_NO":"9249465","DOCKET_NO":"WEVA 2021-0392","DECISION_DT":"12/06/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"5395.00","DECISION_PENALTY_AMT":"5395.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2021-12-06"},{"SOURCE_ROW_NUMBER":"426331","VIOLATION_NO":"9249457","DOCKET_NO":"WEVA 2021-0392","DECISION_DT":"12/06/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4598.00","DECISION_PENALTY_AMT":"4598.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2021-12-06"},{"SOURCE_ROW_NUMBER":"148120","VIOLATION_NO":"9249471","DOCKET_NO":"WEVA 2021-0392","DECISION_DT":"12/06/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3338.00","DECISION_PENALTY_AMT":"3338.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2021-12-06"},{"SOURCE_ROW_NUMBER":"147782","VIOLATION_NO":"9249456","DOCKET_NO":"WEVA 2021-0391","DECISION_DT":"11/18/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"21022.00","DECISION_PENALTY_AMT":"6592.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2021-11-18"},{"SOURCE_ROW_NUMBER":"428021","VIOLATION_NO":"9246698","DOCKET_NO":"WEVA 2021-0316","DECISION_DT":"10/26/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"416.00","DECISION_PENALTY_AMT":"416.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Young","sourceDate":"2021-10-26"},{"SOURCE_ROW_NUMBER":"426274","VIOLATION_NO":"9246699","DOCKET_NO":"WEVA 2021-0316","DECISION_DT":"10/26/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"220.00","DECISION_PENALTY_AMT":"220.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Young","sourceDate":"2021-10-26"},{"SOURCE_ROW_NUMBER":"426273","VIOLATION_NO":"9246696","DOCKET_NO":"WEVA 2021-0316","DECISION_DT":"10/26/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1500.00","DECISION_PENALTY_AMT":"1500.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Young","sourceDate":"2021-10-26"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":6927,"firstDate":"2007-08-22","lastDate":"2021-01-15","metrics":{"recentRows":7,"cpdmSamples":5137,"voidSamples":2614,"validSamples":4313,"maxConcentration":66016.64,"concentrationTotal":69333.08},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2899847","SMP_TAKEN_DT":"1/15/2021","CONC":".035","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"MAINTENANCE FOREMAN","DEVICE_TYPE_CD":"CPDM","sourceDate":"2021-01-15"},{"SOURCE_ROW_NUMBER":"1792367","SMP_TAKEN_DT":"1/14/2021","CONC":"0","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MAINTENANCE FOREMAN","DEVICE_TYPE_CD":"CPDM","sourceDate":"2021-01-14"},{"SOURCE_ROW_NUMBER":"2046748","SMP_TAKEN_DT":"1/13/2021","CONC":".007","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MAINTENANCE FOREMAN","DEVICE_TYPE_CD":"CPDM","sourceDate":"2021-01-13"},{"SOURCE_ROW_NUMBER":"2729430","SMP_TAKEN_DT":"1/12/2021","CONC":".015","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MAINTENANCE FOREMAN","DEVICE_TYPE_CD":"CPDM","sourceDate":"2021-01-12"},{"SOURCE_ROW_NUMBER":"1878159","SMP_TAKEN_DT":"1/11/2021","CONC":"0","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MAINTENANCE FOREMAN","DEVICE_TYPE_CD":"CPDM","sourceDate":"2021-01-11"},{"SOURCE_ROW_NUMBER":"2985212","SMP_TAKEN_DT":"1/8/2021","CONC":".01","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MAINTENANCE FOREMAN","DEVICE_TYPE_CD":"CPDM","sourceDate":"2021-01-08"},{"SOURCE_ROW_NUMBER":"299602","CASS_NUM":"58388572","SMP_TAKEN_DT":"1/7/2021","CONC":".175","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MAINTENANCE FOREMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2021-01-07"},{"SOURCE_ROW_NUMBER":"317579","CASS_NUM":"58388599","SMP_TAKEN_DT":"12/2/2020","CONC":".102","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MAINTENANCE FOREMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2020-12-02"},{"SOURCE_ROW_NUMBER":"2813234","SMP_TAKEN_DT":"11/11/2020","CONC":"1.058","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-11-11"},{"SOURCE_ROW_NUMBER":"2131148","SMP_TAKEN_DT":"11/11/2020","CONC":".83","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-11-11"},{"SOURCE_ROW_NUMBER":"2045330","SMP_TAKEN_DT":"11/11/2020","CONC":".926","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-11-11"},{"SOURCE_ROW_NUMBER":"1960135","SMP_TAKEN_DT":"11/11/2020","CONC":"1.449","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-11-11"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":202,"firstDate":"2007-10-15","lastDate":"2021-07-08","metrics":{"linkedIssuances":202},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":2026,"firstDate":"2007-10-10","lastDate":"2021-03-03","metrics":{"decisions":2026,"ssChanged":175,"recentRows":9,"decisionPenalty":2323442.75,"proposedPenalty":3559959},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"216835","CITATION_NO":"9246700","CITATION_ISSUE_DT":"03/03/2021","DOCKET_NO":"WEVA 2021-0316","DECISION_DT":"10/26/2021","CFR_STANDARD_CODE":"75.364(b)(2)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"729.00","DECISION_PENALTY_AMT":"729.00","sourceDate":"2021-03-03"},{"SOURCE_ROW_NUMBER":"103967","CITATION_NO":"9246699","CITATION_ISSUE_DT":"03/02/2021","DOCKET_NO":"WEVA 2021-0316","DECISION_DT":"10/26/2021","CFR_STANDARD_CODE":"75.364(b)(2)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"220.00","DECISION_PENALTY_AMT":"220.00","sourceDate":"2021-03-02"},{"SOURCE_ROW_NUMBER":"386897","CITATION_NO":"9246697","CITATION_ISSUE_DT":"02/16/2021","DOCKET_NO":"WEVA 2021-0316","DECISION_DT":"10/26/2021","CFR_STANDARD_CODE":"75.1725(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1624.00","DECISION_PENALTY_AMT":"1624.00","sourceDate":"2021-02-16"},{"SOURCE_ROW_NUMBER":"104362","CITATION_NO":"9246698","CITATION_ISSUE_DT":"02/16/2021","DOCKET_NO":"WEVA 2021-0316","DECISION_DT":"10/26/2021","CFR_STANDARD_CODE":"75.1107-4(c)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"416.00","DECISION_PENALTY_AMT":"416.00","sourceDate":"2021-02-16"},{"SOURCE_ROW_NUMBER":"388126","CITATION_NO":"9246696","CITATION_ISSUE_DT":"02/09/2021","DOCKET_NO":"WEVA 2021-0316","DECISION_DT":"10/26/2021","CFR_STANDARD_CODE":"75.1725(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1500.00","DECISION_PENALTY_AMT":"1500.00","sourceDate":"2021-02-09"},{"SOURCE_ROW_NUMBER":"159683","CITATION_NO":"9246695","CITATION_ISSUE_DT":"01/20/2021","DOCKET_NO":"WEVA 2021-0247","DECISION_DT":"10/05/2021","CFR_STANDARD_CODE":"75.1202-1(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"125.00","DECISION_PENALTY_AMT":"125.00","sourceDate":"2021-01-20"},{"SOURCE_ROW_NUMBER":"329950","CITATION_NO":"9246694","CITATION_ISSUE_DT":"01/13/2021","DOCKET_NO":"WEVA 2021-0247","DECISION_DT":"10/05/2021","CFR_STANDARD_CODE":"75.1725(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1278.00","DECISION_PENALTY_AMT":"1278.00","sourceDate":"2021-01-13"},{"SOURCE_ROW_NUMBER":"47459","CITATION_NO":"9246693","CITATION_ISSUE_DT":"01/13/2021","DOCKET_NO":"WEVA 2021-0246","DECISION_DT":"09/15/2021","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"810.00","DECISION_PENALTY_AMT":"810.00","sourceDate":"2021-01-13"},{"SOURCE_ROW_NUMBER":"216834","CITATION_NO":"9246692","CITATION_ISSUE_DT":"01/07/2021","DOCKET_NO":"WEVA 2021-0307","DECISION_DT":"10/26/2021","CFR_STANDARD_CODE":"75.1714-4(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3616.00","DECISION_PENALTY_AMT":"3616.00","sourceDate":"2021-01-07"},{"SOURCE_ROW_NUMBER":"166025","CITATION_NO":"9246110","CITATION_ISSUE_DT":"12/16/2020","DOCKET_NO":"WEVA 2021-0307","DECISION_DT":"10/26/2021","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"302.00","DECISION_PENALTY_AMT":"302.00","sourceDate":"2020-12-16"},{"SOURCE_ROW_NUMBER":"159667","CITATION_NO":"9246109","CITATION_ISSUE_DT":"12/15/2020","DOCKET_NO":"WEVA 2021-0307","DECISION_DT":"10/26/2021","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"5844.00","DECISION_PENALTY_AMT":"2600.00","sourceDate":"2020-12-15"},{"SOURCE_ROW_NUMBER":"50078","CITATION_NO":"9246689","CITATION_ISSUE_DT":"12/07/2020","DOCKET_NO":"WEVA 2021-0307","DECISION_DT":"10/26/2021","CFR_STANDARD_CODE":"75.363(b)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"2844.00","DECISION_PENALTY_AMT":"1461.00","sourceDate":"2020-12-07"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":995,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":9,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":226,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":9,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":7,"firstDate":"2006-04-13","lastDate":"2015-10-26","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":5},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":200,"firstDate":"2006-12-21","lastDate":"2026-07-06","metrics":{"inspectors":574,"recentRows":25,"onSiteHours":17565,"inspectionHours":28362.25,"inspectionSamples":2288},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"699785","EVENT_NO":"6316104","INSPECTION_BEGIN_DT":"07/06/2026","INSPECTION_END_DT":"07/06/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2026-07-06"},{"SOURCE_ROW_NUMBER":"825331","EVENT_NO":"F022D71","INSPECTION_BEGIN_DT":"04/22/2026","INSPECTION_END_DT":"04/22/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2026-04-22"},{"SOURCE_ROW_NUMBER":"1039376","EVENT_NO":"4425658","INSPECTION_BEGIN_DT":"03/04/2026","INSPECTION_END_DT":"03/05/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2026-03-04"},{"SOURCE_ROW_NUMBER":"1044102","EVENT_NO":"4425655","INSPECTION_BEGIN_DT":"10/16/2025","INSPECTION_END_DT":"10/16/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.25","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2025-10-16"},{"SOURCE_ROW_NUMBER":"125201","EVENT_NO":"F00C75D","INSPECTION_BEGIN_DT":"08/14/2025","INSPECTION_END_DT":"08/14/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2025-08-14"},{"SOURCE_ROW_NUMBER":"714878","EVENT_NO":"6322980","INSPECTION_BEGIN_DT":"04/16/2025","INSPECTION_END_DT":"04/16/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2025-04-16"},{"SOURCE_ROW_NUMBER":"1157626","EVENT_NO":"4425650","INSPECTION_BEGIN_DT":"03/04/2025","INSPECTION_END_DT":"03/04/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2025-03-04"},{"SOURCE_ROW_NUMBER":"159899","EVENT_NO":"6322966","INSPECTION_BEGIN_DT":"12/17/2024","INSPECTION_END_DT":"12/17/2024","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.25","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2024-12-17"},{"SOURCE_ROW_NUMBER":"317630","EVENT_NO":"6311850","INSPECTION_BEGIN_DT":"08/21/2024","INSPECTION_END_DT":"08/21/2024","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2024-08-21"},{"SOURCE_ROW_NUMBER":"367118","EVENT_NO":"6321416","INSPECTION_BEGIN_DT":"06/13/2024","INSPECTION_END_DT":"06/13/2024","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2024-06-13"},{"SOURCE_ROW_NUMBER":"1107777","EVENT_NO":"6321468","INSPECTION_BEGIN_DT":"03/27/2024","INSPECTION_END_DT":"03/27/2024","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2024-03-27"},{"SOURCE_ROW_NUMBER":"93492","EVENT_NO":"6321462","INSPECTION_BEGIN_DT":"12/29/2023","INSPECTION_END_DT":"12/29/2023","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.5","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2023-12-29"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":196,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2026-Q2":{"hours":0,"employees":0,"production":0},"2026-Q1":{"hours":0,"employees":0,"production":0},"2025-Q4":{"hours":0,"employees":0,"production":0},"2025-Q3":{"hours":0,"employees":0,"production":0},"2025-Q2":{"hours":0,"employees":0,"production":0},"2025-Q1":{"hours":0,"employees":0,"production":0},"2024-Q4":{"hours":0,"employees":0,"production":0},"2024-Q2":{"hours":0,"employees":0,"production":0},"2024-Q1":{"hours":0,"employees":0,"production":0},"2023-Q4":{"hours":0,"employees":0,"production":0},"2023-Q3":{"hours":0,"employees":0,"production":0},"2023-Q2":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":38,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2013":{"hours":235023,"employees":98,"production":363717},"2014":{"hours":333656,"employees":130,"production":561925},"2015":{"hours":258969,"employees":120,"production":390411},"2016":{"hours":193819,"employees":79,"production":314574},"2017":{"hours":314556,"employees":134,"production":379819},"2018":{"hours":298204,"employees":132,"production":333792},"2019":{"hours":340551,"employees":145,"production":330492},"2020":{"hours":203859,"employees":115,"production":219113},"2021":{"hours":27819,"employees":25,"production":0},"2026":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":267,"firstDate":"2008-04-14","lastDate":"2020-09-24","metrics":{"recentRows":0,"doseOver100":34,"actDoseTotal":17931,"pelDoseTotal":14070},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"257039","EVENT_NO":"6315615","SURVEY_DATE":"09/24/2020","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"20","MANUFACTURER_CD":"119","ACT_DOSE_85":"34","PEL_DOSE_90":"27","SURVEY_TYPE":"I","sourceDate":"2020-09-24"},{"SOURCE_ROW_NUMBER":"257038","EVENT_NO":"6315615","SURVEY_DATE":"09/24/2020","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"64","PEL_DOSE_90":"50","SURVEY_TYPE":"I","sourceDate":"2020-09-24"},{"SOURCE_ROW_NUMBER":"257037","EVENT_NO":"6315615","SURVEY_DATE":"09/24/2020","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"30","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2020-09-24"},{"SOURCE_ROW_NUMBER":"257036","EVENT_NO":"6315615","SURVEY_DATE":"09/24/2020","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"111","PEL_DOSE_90":"95","SURVEY_TYPE":"I","sourceDate":"2020-09-24"},{"SOURCE_ROW_NUMBER":"257035","EVENT_NO":"6315615","SURVEY_DATE":"09/24/2020","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"038","ACT_DOSE_85":"34","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2020-09-24"},{"SOURCE_ROW_NUMBER":"257034","EVENT_NO":"6315612","SURVEY_DATE":"06/03/2020","OCCUPATION_CD_DESC":"BELT CLEANER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"48","PEL_DOSE_90":"30","SURVEY_TYPE":"I","sourceDate":"2020-06-03"},{"SOURCE_ROW_NUMBER":"257033","EVENT_NO":"6315612","SURVEY_DATE":"06/03/2020","OCCUPATION_CD_DESC":"MOTORMAN","MACHINE_CD":"25","MANUFACTURER_CD":"119","ACT_DOSE_85":"18","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2020-06-03"},{"SOURCE_ROW_NUMBER":"257032","EVENT_NO":"6315612","SURVEY_DATE":"06/03/2020","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"33","PEL_DOSE_90":"24","SURVEY_TYPE":"I","sourceDate":"2020-06-03"},{"SOURCE_ROW_NUMBER":"257031","EVENT_NO":"6315612","SURVEY_DATE":"06/03/2020","OCCUPATION_CD_DESC":"DISPATCHER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"2","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2020-06-03"},{"SOURCE_ROW_NUMBER":"257030","EVENT_NO":"6315612","SURVEY_DATE":"06/03/2020","OCCUPATION_CD_DESC":"MAINTENANCE FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"63","PEL_DOSE_90":"53","SURVEY_TYPE":"I","sourceDate":"2020-06-03"},{"SOURCE_ROW_NUMBER":"257029","EVENT_NO":"6314769","SURVEY_DATE":"12/04/2019","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"76","PEL_DOSE_90":"58","SURVEY_TYPE":"I","sourceDate":"2019-12-04"},{"SOURCE_ROW_NUMBER":"257028","EVENT_NO":"6314769","SURVEY_DATE":"12/04/2019","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"58","PEL_DOSE_90":"43","SURVEY_TYPE":"I","sourceDate":"2019-12-04"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":239,"firstDate":"2007-11-28","lastDate":"2021-01-07","metrics":{"recentRows":1,"voidSamples":33,"maxQuartzPct":28.5,"validSamples":206,"quartzPctTotal":1623.7},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"11683","CASSETTE_NO":"58388572","SAMPLE_DT":"01/07/2021","QUARTZ_PCT":"04.3","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"MAINTENANCE FOREMAN","SAMPLE_TYPE_DESC":"PART 90 MINER","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2021-01-07"},{"SOURCE_ROW_NUMBER":"102553","CASSETTE_NO":"58388504","SAMPLE_DT":"11/04/2020","QUARTZ_PCT":"04.8","QUARTZ_MICROGRAMS":"26","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-11-04"},{"SOURCE_ROW_NUMBER":"39204","CASSETTE_NO":"58388278","SAMPLE_DT":"11/04/2020","QUARTZ_PCT":"07.1","QUARTZ_MICROGRAMS":"11","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-11-04"},{"SOURCE_ROW_NUMBER":"33224","CASSETTE_NO":"58388286","SAMPLE_DT":"11/04/2020","QUARTZ_PCT":"05.7","QUARTZ_MICROGRAMS":"13","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-11-04"},{"SOURCE_ROW_NUMBER":"136255","CASSETTE_NO":"58388090","SAMPLE_DT":"11/03/2020","QUARTZ_PCT":"06.4","QUARTZ_MICROGRAMS":"11","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-11-03"},{"SOURCE_ROW_NUMBER":"39356","CASSETTE_NO":"58388093","SAMPLE_DT":"11/03/2020","QUARTZ_PCT":"06.2","QUARTZ_MICROGRAMS":"10","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-11-03"},{"SOURCE_ROW_NUMBER":"159200","CASSETTE_NO":"58388510","SAMPLE_DT":"09/23/2020","QUARTZ_PCT":"05.8","QUARTZ_MICROGRAMS":"10","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-09-23"},{"SOURCE_ROW_NUMBER":"44991","CASSETTE_NO":"58388195","SAMPLE_DT":"06/04/2020","QUARTZ_PCT":"05.6","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"CONTROL FILTER INVALID","sourceDate":"2020-06-04"},{"SOURCE_ROW_NUMBER":"165679","CASSETTE_NO":"58388636","SAMPLE_DT":"06/03/2020","QUARTZ_PCT":"02.5","QUARTZ_MICROGRAMS":"5","OCC_CODE_DESC":"MAINTENANCE FOREMAN","SAMPLE_TYPE_DESC":"PART 90 MINER","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-06-03"},{"SOURCE_ROW_NUMBER":"80035","CASSETTE_NO":"58388188","SAMPLE_DT":"06/02/2020","QUARTZ_PCT":"05.7","QUARTZ_MICROGRAMS":"15","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-06-02"},{"SOURCE_ROW_NUMBER":"5695","CASSETTE_NO":"58388203","SAMPLE_DT":"06/02/2020","QUARTZ_PCT":"05.7","QUARTZ_MICROGRAMS":"9","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-06-02"},{"SOURCE_ROW_NUMBER":"120803","CASSETTE_NO":"58388607","SAMPLE_DT":"05/27/2020","QUARTZ_PCT":"07.2","QUARTZ_MICROGRAMS":"67","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-05-27"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":2950,"firstDate":"2007-07-03","lastDate":"2023-03-21","metrics":{"ss":751,"amountDue":2705387.75,"contested":42,"amountPaid":2624989.18,"recentRows":14,"section104d":41,"unterminated":17,"proposedPenalty":3922570},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2897250","VIOLATION_NO":"9552571","VIOLATION_ISSUE_DT":"03/21/2023","SIG_SUB":"Y","PART_SECTION":"77.208(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/29/2023","PROPOSED_PENALTY":"252","AMOUNT_DUE":"252","AMOUNT_PAID":"252","CONTESTED_IND":"N","sourceDate":"2023-03-21"},{"SOURCE_ROW_NUMBER":"2897249","VIOLATION_NO":"9552570","VIOLATION_ISSUE_DT":"03/21/2023","SIG_SUB":"N","PART_SECTION":"77.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/21/2023","PROPOSED_PENALTY":"143","AMOUNT_DUE":"143","AMOUNT_PAID":"143","CONTESTED_IND":"N","sourceDate":"2023-03-21"},{"SOURCE_ROW_NUMBER":"2897248","VIOLATION_NO":"9552569","VIOLATION_ISSUE_DT":"03/21/2023","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/21/2023","PROPOSED_PENALTY":"143","AMOUNT_DUE":"143","AMOUNT_PAID":"143","CONTESTED_IND":"N","sourceDate":"2023-03-21"},{"SOURCE_ROW_NUMBER":"2897247","VIOLATION_NO":"9552568","VIOLATION_ISSUE_DT":"03/21/2023","SIG_SUB":"N","PART_SECTION":"75.1712-3(c)(2)(iv)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/21/2023","PROPOSED_PENALTY":"143","AMOUNT_DUE":"143","AMOUNT_PAID":"143","CONTESTED_IND":"N","sourceDate":"2023-03-21"},{"SOURCE_ROW_NUMBER":"2897246","VIOLATION_NO":"9552567","VIOLATION_ISSUE_DT":"03/21/2023","SIG_SUB":"Y","PART_SECTION":"75.1712","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/29/2023","PROPOSED_PENALTY":"376","AMOUNT_DUE":"376","AMOUNT_PAID":"376","CONTESTED_IND":"N","sourceDate":"2023-03-21"},{"SOURCE_ROW_NUMBER":"2897191","VIOLATION_NO":"9246700","VIOLATION_ISSUE_DT":"03/03/2021","SIG_SUB":"N","PART_SECTION":"75.364(b)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"03/16/2021","PROPOSED_PENALTY":"729","AMOUNT_DUE":"729","AMOUNT_PAID":"729","CONTESTED_IND":"N","sourceDate":"2021-03-03"},{"SOURCE_ROW_NUMBER":"2897190","VIOLATION_NO":"9246699","VIOLATION_ISSUE_DT":"03/02/2021","SIG_SUB":"N","PART_SECTION":"75.364(b)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/16/2021","PROPOSED_PENALTY":"220","AMOUNT_DUE":"220","AMOUNT_PAID":"220","CONTESTED_IND":"N","sourceDate":"2021-03-02"},{"SOURCE_ROW_NUMBER":"2897189","VIOLATION_NO":"9246698","VIOLATION_ISSUE_DT":"02/16/2021","SIG_SUB":"N","PART_SECTION":"75.1107-4(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/19/2021","PROPOSED_PENALTY":"416","AMOUNT_DUE":"416","AMOUNT_PAID":"416","CONTESTED_IND":"N","sourceDate":"2021-02-16"},{"SOURCE_ROW_NUMBER":"2897188","VIOLATION_NO":"9246697","VIOLATION_ISSUE_DT":"02/16/2021","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/19/2021","PROPOSED_PENALTY":"1624","AMOUNT_DUE":"1624","AMOUNT_PAID":"1624","CONTESTED_IND":"N","sourceDate":"2021-02-16"},{"SOURCE_ROW_NUMBER":"2897187","VIOLATION_NO":"9246696","VIOLATION_ISSUE_DT":"02/09/2021","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/16/2021","PROPOSED_PENALTY":"1500","AMOUNT_DUE":"1500","AMOUNT_PAID":"1500","CONTESTED_IND":"N","sourceDate":"2021-02-09"},{"SOURCE_ROW_NUMBER":"2897186","VIOLATION_NO":"9246695","VIOLATION_ISSUE_DT":"01/20/2021","SIG_SUB":"N","PART_SECTION":"75.1202-1(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/02/2021","PROPOSED_PENALTY":"125","AMOUNT_DUE":"125","AMOUNT_PAID":"125","CONTESTED_IND":"N","sourceDate":"2021-01-20"},{"SOURCE_ROW_NUMBER":"2897185","VIOLATION_NO":"9246694","VIOLATION_ISSUE_DT":"01/13/2021","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/14/2021","PROPOSED_PENALTY":"1278","AMOUNT_DUE":"1278","AMOUNT_PAID":"1278","CONTESTED_IND":"N","sourceDate":"2021-01-13"}]}],"safety":{"href":"/api/v1/mines/4609152/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609152/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.208","heading":"Storage of materials.","id":"77.208","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.208","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Materials shall be stored and stacked in a manner which minimizes stumbling or fall-of-material hazards.\n\n(b) Materials that can create hazards if accidentally liberated from their containers shall be stored in a manner that minimizes the dangers.\n\n(c) Containers holding hazardous materials must be of a type approved for such use by recognized agencies.\n\n(d) Compressed and liquid gas cylinders shall be secured in a safe manner.\n\n(e) Valves on compressed gas cylinders shall be protected by covers when being transported or stored, and by a safe location when the cylinders are in use.\n\n[36 FR 9364, May 22, 1971, as amended at 67 FR 42389, June 21, 2002]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.512","heading":"Inspection and cover plates.","id":"77.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.512","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Inspection and cover plates on electrical equipment shall be kept in place at all times except during testing or repairs.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1110","heading":"Examination and maintenance of firefighting equipment.","id":"77.1110","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1110","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment shall be continuously maintained in a usable and operative condition. Fire extinguishers shall be examined at least once every 6 months and the date of such examination shall be recorded on a permanent tag attached to the extinguisher.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","heading":"Minimum requirements of surface bathing facilities, change rooms, and sanitary toilet facilities.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1712-3","part":"75","subchapter":"O","subpart":"R","id":"75.1712-3","citation":"30 CFR 75.1712-3","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Bath houses and toilet facilities.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1712","part":"75","subchapter":"O","subpart":"R","id":"75.1712","citation":"30 CFR 75.1712","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.364","heading":"Weekly examination.","id":"75.364","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.364","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Worked-out areas. (1) At least every 7 days, a certified person shall examine unsealed worked-out areas where no pillars have been recovered by traveling to the area of deepest penetration; measuring methane and oxygen concentrations and air quantities and making tests to determine if the air is moving in the proper direction in the area. The locations of measurement points where tests and measurements will be performed shall be included in the mine ventilation plan and shall be adequate in number and location to assure ventilation and air quality in the area. Air quantity measurements shall also be made where the air enters and leaves the worked-out area. An alternative method of evaluating the ventilation of the area may be approved in the ventilation plan.\n\n(2) At least every 7 days, a certified person shall evaluate the effectiveness of bleeder systems required by § 75.334 as follows:\n\n(i) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in its proper direction shall be made where air enters the worked-out area.\n\n(ii) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in the proper direction shall be made immediately before the air enters a return split of air.\n\n(iii) At least one entry of each set of bleeder entries used as part of a bleeder system under § 75.334 shall be traveled in its entirety. Measurements of methane and oxygen concentrations and air quantities and a test to determine if the air is moving in the proper direction shall be made at the measurement point locations specified in the mine ventilation plan to determine the effectiveness of the bleeder system.\n\n(iv) In lieu of the requirements of paragraphs (a)(2)(i) and (iii) of this section, an alternative method of evaluation may be specified in the ventilation plan provided the alternative method results in proper evaluation of the effectiveness of the bleeder system.\n\n(b) Hazardous conditions and violations of mandatory health or safety standards. At least every 7 days, an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(8) of this section shall be made by a certified person designated by the operator at the following locations:\n\n(1) In at least one entry of each intake air course, in its entirety, so that the entire air course is traveled.\n\n(2) In at least one entry of each return air course, in its entirety, so that the entire air course is traveled.\n\n(3) In each longwall or shortwall travelway in its entirety, so that the entire travelway is traveled.\n\n(4) At each seal along return and bleeder air courses and at each seal along intake air courses not examined under § 75.360(b)(5).\n\n(5) In each escapeway so that the entire escapeway is traveled.\n\n(6) On each working section not examined under § 75.360(b)(3) during the previous 7 days.\n\n(7) At each water pump not examined during a preshift examination conducted during the previous 7 days.\n\n(8) Weekly examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust; and\n\n(iv) § 75.1403—maintenance of off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) Measurements and tests. At least every 7 days, a certified person shall—\n\n(1) Determine the volume of air entering the main intakes and in each intake split;\n\n(2) Determine the volume of air and test for methane in the last open crosscut in any pair or set of developing entries or rooms, in the return of each split of air immediately before it enters the main returns, and where the air leaves the main returns; and\n\n(3) Test for methane in the return entry nearest each set of seals immediately after the air passes the seals.\n\n(d) Hazardous conditions shall be corrected immediately. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Any violation of the nine mandatory health or safety standards found during a weekly examination shall be corrected.\n\n(e) The weekly examination may be conducted at the same time as the preshift or on-shift examinations.\n\n(f) (1) The weekly examination is not required during any 7 day period in which no one enters any underground area of the mine.\n\n(2) Except for certified persons required to make examinations, no one shall enter any underground area of the mine if a weekly examination has not been completed within the previous 7 days.\n\n(g) Certification. The person making the weekly examinations shall certify by initials, date, and the time that the examination was made. Certifications and times shall appear at enough locations to show that the entire area has been examined.\n\n(h) Recordkeeping. At the completion of any shift during which a portion of a weekly examination is conducted, a record of the results of each weekly examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards found during each examination and their locations, the corrective action taken, and the results and location of air and methane measurements, shall be made. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the person making the examination or a person designated by the operator. If made by a person other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(i) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 77 FR 20715, Apr. 6, 2012]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-4","heading":"Automatic fire sensors and manual actuators; installation; minimum requirements.","id":"75.1107-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a)(1) Where fire suppression devices are installed on unattended underground equipment, one or more point-type sensors or equivalent shall be installed for each 50 square feet of top surface area, or fraction thereof, of such equipment, and each sensor shall be designed to activate the first suppression system and disconnect the electrical power source to the equipment protected, and, except where sprinklers are used, there shall be in addition, a manual actuator installed to operate the system. Where sprinklers are used, provision shall be made for manual application of water to the protected equipment in lieu of a manual actuator.\n\n(2) Two or more manual actuators, where practicable, shall be installed, as provided in paragraphs (a)(2) (i) and (ii) of this section, to activate fire suppression devices on attended equipment purchased on or after the effective date of this § 75.1107-4. At least one manual actuator shall be used on equipment purchased prior to the effective date of this § 75.1107-4.\n\n(i) Manual actuators installed on attended equipment regularly operated by a miner, as provided in § 75.1107-1(c)(1) shall be located at different locations on the equipment, and at least one manual actuator shall be located within easy reach of the operator's normal operating position.\n\n(ii) Manual actuators to activate fire suppression devices on attended equipment not regularly operated by a miner, as provided in § 75.1107-1(c)(2), shall be installed at different location, and at least one manual actuator shall be installed so as to be easily reached by the miner at the jobsite or by persons approaching the equipment.\n\n(b) Sensors shall, where practicable, be installed in accordance with the recommendations set forth in National Fire Code No. 72A “Local Protective Signaling Systems” (NFPA No. 72A-1967).\n\n(c) On unattended equipment the fire suppression device shall operate independently of the power to the main motor (or equivalent) so it will remain operative if the circuit breakers (or other protective device) actuates. On attended equipment powered through a trailing cable the fire suppression device shall operate independently of the electrical power provided by the cable.\n\n(d) Point-type sensors (such as thermocouple, bimetallic strip, or rate of temperature rise) located in ventilated passageways shall be installed downwind from the equipment to be protected.\n\n(e) Sensor systems shall include a device or method for determining their operative condition.\n\n[37 FR 15301, July 29, 1972]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1725","heading":"Machinery and equipment; operation and maintenance.","id":"75.1725","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1725","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":3},{"chapter":"I","heading":"Temporary notations, revisions, and supplements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-M/section-75.1202-1","part":"75","subchapter":"O","subpart":"M","id":"75.1202-1","citation":"30 CFR 75.1202-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609152","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}