{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4609129","name":"JOLO MINE","status":"Abandoned","status_date":"2025-03-27","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Mcdowell","nearest_town":"Jolo","operator_id":"P16417","operator_name":"CHAD COAL CORP","controller_id":"C07191","controller_name":"James  Taylor; Coy  Taylor","district":"C04","office":"Beckley District","employees":0,"latitude":37.313611,"longitude":-81.848333},"coverage":{"contributingSources":15,"registeredSources":20,"sourceRows":1377},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609129","name":"JOLO MINE"},"operator":{"type":"operator","id":"P16417","name":"CHAD COAL CORP"},"controller":{"type":"controller","id":"C07191","name":"James  Taylor; Coy  Taylor"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07191","name":"Coy  Taylor et al"},"object":{"type":"mine","id":"4609129","name":"JOLO MINE"},"validFrom":"1984-10-04","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609129|C07191|1984-10-04|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C01767","name":"Sunoco, Inc."},"object":{"type":"mine","id":"4609129","name":"JOLO MINE"},"validFrom":"1994-09-01","validTo":"2012-01-16","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609129|C01767|1994-09-01|2012-01-16"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23229","name":"Vansant Coal Corporation"},"object":{"type":"mine","id":"4609129","name":"JOLO MINE"},"validFrom":"2005-11-09","validTo":"2006-06-01","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609129|P23229|2005-11-09|2006-06-01"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C01767","name":"Sunoco, Inc."},"object":{"type":"operator","id":"P23229","name":"Vansant Coal Corporation"},"validFrom":"2005-11-09","validTo":"2006-06-01","current":false,"derived":true,"evidenceMineId":"4609129","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609129|P23229|2005-11-09|C01767|1994-09-01|56017"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P16417","name":"Chad Coal Corp"},"object":{"type":"mine","id":"4609129","name":"JOLO MINE"},"validFrom":"2006-06-02","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609129|P16417|2006-06-02|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07191","name":"Coy  Taylor et al"},"object":{"type":"operator","id":"P16417","name":"Chad Coal Corp"},"validFrom":"2006-06-02","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609129","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609129|P16417|2006-06-02|C07191|1984-10-04|74041"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07191","name":"James  Taylor et al"},"object":{"type":"operator","id":"P16417","name":"Chad Coal Corp"},"validFrom":"2006-06-02","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609129","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609129|P16417|2006-06-02|C07191|1984-10-04|74042"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0104093","name":"SunCoke Energy Incorporated"},"object":{"type":"mine","id":"4609129","name":"JOLO MINE"},"validFrom":"2012-01-17","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609129|0104093|2012-01-17|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0104093","name":"SunCoke Energy Incorporated"},"object":{"type":"operator","id":"P23229","name":"Vansant Coal Corporation"},"validFrom":"2012-01-17","validTo":"2006-06-01","current":false,"derived":true,"evidenceMineId":"4609129","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609129|P23229|2005-11-09|0104093|2012-01-17|18100"}}],"coverage":{"historyRecords":4,"edgeCount":9,"intervalAnomalies":1,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":4,"firstDate":"2007-05-10","lastDate":"2009-10-21","metrics":{"daysLost":104,"injuries":3,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"137229","DOCUMENT_NO":"220093060029","ACCIDENT_DT":"10/21/2009","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"53","NARRATIVE":"Operator went across hump going to miner got head into top and shuttle car","sourceDate":"2009-10-21"},{"SOURCE_ROW_NUMBER":"102714","DOCUMENT_NO":"220091460044","ACCIDENT_DT":"05/15/2009","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Roof fall has occurred on the #2 section ( MMU 002-0) The fall  was 42 inches thick, 17 feet wide and 22 feet long in the #4 right crosscut at survey station #853.(Narrative per Violation No. 8070199)","sourceDate":"2009-05-15"},{"SOURCE_ROW_NUMBER":"68420","DOCUMENT_NO":"220073550058","ACCIDENT_DT":"12/06/2007","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Superintendent","NO_INJURIES":"1","DAYS_LOST":"49","NARRATIVE":"Two employees were installing air lock doors for the new 002 section. One had cut off a section of metal from the bottom of the door exposing a hot sharp point of metal. He tripped and fell on the metal causing a puncture wound to his upper left leg.","sourceDate":"2007-12-06"},{"SOURCE_ROW_NUMBER":"16862","DOCUMENT_NO":"220071970058","ACCIDENT_DT":"05/10/2007","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"EE & superintendent were installing track rail when inj. EE flipped over a section of track rail & caught his finger lacerating the tip of finger. Required stitches.","sourceDate":"2007-05-10"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2025-03-27","lastDate":"2025-03-27","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":302,"firstDate":"2007-02-06","lastDate":"2015-01-13","metrics":{"ss":82,"delinquent":299,"recentRows":0,"paidPenalty":99237,"proposedPenalty":114537,"currentAssessment":99237},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1858416","VIOLATION_NO":"9062680","ISSUE_DT":"01/13/2015","CFR_STANDARD_CD":"77.1911(b)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-01-13"},{"SOURCE_ROW_NUMBER":"1869643","VIOLATION_NO":"9020181","ISSUE_DT":"10/03/2014","CFR_STANDARD_CD":"75.1722(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-10-03"},{"SOURCE_ROW_NUMBER":"1837461","VIOLATION_NO":"7196242","ISSUE_DT":"11/20/2012","CFR_STANDARD_CD":"75.900-4","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-11-20"},{"SOURCE_ROW_NUMBER":"1837460","VIOLATION_NO":"7196241","ISSUE_DT":"11/20/2012","CFR_STANDARD_CD":"75.342(a)(4)(ii)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-11-20"},{"SOURCE_ROW_NUMBER":"1837459","VIOLATION_NO":"7196240","ISSUE_DT":"11/19/2012","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"499.00","CURRENT_ASSESSMENT_AMT":"499.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-11-19"},{"SOURCE_ROW_NUMBER":"1837458","VIOLATION_NO":"7196239","ISSUE_DT":"11/15/2012","CFR_STANDARD_CD":"75.515","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-11-15"},{"SOURCE_ROW_NUMBER":"1837457","VIOLATION_NO":"7196238","ISSUE_DT":"11/15/2012","CFR_STANDARD_CD":"75.1731(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"460.00","CURRENT_ASSESSMENT_AMT":"460.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-11-15"},{"SOURCE_ROW_NUMBER":"1837456","VIOLATION_NO":"7196237","ISSUE_DT":"11/15/2012","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1304.00","CURRENT_ASSESSMENT_AMT":"1304.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-11-15"},{"SOURCE_ROW_NUMBER":"1837455","VIOLATION_NO":"7196235","ISSUE_DT":"10/29/2012","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"243.00","CURRENT_ASSESSMENT_AMT":"243.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-10-29"},{"SOURCE_ROW_NUMBER":"1837454","VIOLATION_NO":"7196234","ISSUE_DT":"10/29/2012","CFR_STANDARD_CD":"75.605","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-10-29"},{"SOURCE_ROW_NUMBER":"1837453","VIOLATION_NO":"7196233","ISSUE_DT":"10/29/2012","CFR_STANDARD_CD":"75.604(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-10-29"},{"SOURCE_ROW_NUMBER":"1837452","VIOLATION_NO":"7196232","ISSUE_DT":"10/29/2012","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-10-29"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":3,"firstDate":"2009-09-29","lastDate":"2011-12-16","metrics":{"appeals":0,"decisions":3,"recentRows":0,"decisionPenalty":2784,"originalPenalty":23102},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"300045","VIOLATION_NO":"8127821","DOCKET_NO":"WEVA 2011-1683","DECISION_DT":"12/16/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2901.00","DECISION_PENALTY_AMT":"392.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2011-12-16"},{"SOURCE_ROW_NUMBER":"71743","VIOLATION_NO":"8127820","DOCKET_NO":"WEVA 2011-1683","DECISION_DT":"12/16/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2901.00","DECISION_PENALTY_AMT":"392.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2011-12-16"},{"SOURCE_ROW_NUMBER":"26650","VIOLATION_NO":"7271773","DOCKET_NO":"WEVA 2008-1573","DECISION_DT":"09/29/2009","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"17300.00","DECISION_PENALTY_AMT":"2000.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2009-09-29"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":503,"firstDate":"2006-07-19","lastDate":"2013-02-07","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":17,"validSamples":486,"maxConcentration":5.449,"concentrationTotal":399.825},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"310944","CASS_NUM":"51202918","SMP_TAKEN_DT":"2/7/2013","CONC":".764","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-02-07"},{"SOURCE_ROW_NUMBER":"289237","CASS_NUM":"51202999","SMP_TAKEN_DT":"2/4/2013","CONC":"1.223","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-02-04"},{"SOURCE_ROW_NUMBER":"1305529","CASS_NUM":"51224337","SMP_TAKEN_DT":"1/11/2013","CONC":".514","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-01-11"},{"SOURCE_ROW_NUMBER":"760590","CASS_NUM":"51224332","SMP_TAKEN_DT":"1/10/2013","CONC":"1.926","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-01-10"},{"SOURCE_ROW_NUMBER":"1621429","CASS_NUM":"51223993","SMP_TAKEN_DT":"1/9/2013","CONC":".905","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-01-09"},{"SOURCE_ROW_NUMBER":"1275330","CASS_NUM":"51224264","SMP_TAKEN_DT":"1/8/2013","CONC":".076","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"UNREPRESENTATIVE SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-01-08"},{"SOURCE_ROW_NUMBER":"1575973","CASS_NUM":"51224260","SMP_TAKEN_DT":"1/7/2013","CONC":".641","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-01-07"},{"SOURCE_ROW_NUMBER":"703510","CASS_NUM":"51224249","SMP_TAKEN_DT":"12/7/2012","CONC":".304","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-12-07"},{"SOURCE_ROW_NUMBER":"1563449","CASS_NUM":"57983503","SMP_TAKEN_DT":"11/19/2012","CONC":".309","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-11-19"},{"SOURCE_ROW_NUMBER":"1228763","CASS_NUM":"57983498","SMP_TAKEN_DT":"11/19/2012","CONC":".293","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-11-19"},{"SOURCE_ROW_NUMBER":"875006","CASS_NUM":"57983497","SMP_TAKEN_DT":"11/19/2012","CONC":".346","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-11-19"},{"SOURCE_ROW_NUMBER":"615323","CASS_NUM":"57983504","SMP_TAKEN_DT":"11/19/2012","CONC":".356","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-11-19"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":5,"firstDate":"2007-10-24","lastDate":"2012-04-18","metrics":{"linkedIssuances":5},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":3,"firstDate":"2007-10-11","lastDate":"2011-02-24","metrics":{"decisions":3,"ssChanged":0,"recentRows":0,"decisionPenalty":2784,"proposedPenalty":23102},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"397764","CITATION_NO":"8127820","CITATION_ISSUE_DT":"02/24/2011","DOCKET_NO":"WEVA 2011-1683","DECISION_DT":"12/16/2011","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2901.00","DECISION_PENALTY_AMT":"392.00","sourceDate":"2011-02-24"},{"SOURCE_ROW_NUMBER":"396980","CITATION_NO":"8127821","CITATION_ISSUE_DT":"02/24/2011","DOCKET_NO":"WEVA 2011-1683","DECISION_DT":"12/16/2011","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2901.00","DECISION_PENALTY_AMT":"392.00","sourceDate":"2011-02-24"},{"SOURCE_ROW_NUMBER":"60226","CITATION_NO":"7271773","CITATION_ISSUE_DT":"10/11/2007","DOCKET_NO":"WEVA 2008-1573","DECISION_DT":"09/29/2009","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"17300.00","DECISION_PENALTY_AMT":"2000.00","sourceDate":"2007-10-11"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":4,"firstDate":"2005-11-09","lastDate":"2006-06-02","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":55,"firstDate":"2006-01-19","lastDate":"2025-03-27","metrics":{"inspectors":77,"recentRows":2,"onSiteHours":1634.25,"inspectionHours":2990.5,"inspectionSamples":438},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"77481","EVENT_NO":"F02A960","INSPECTION_BEGIN_DT":"03/27/2025","INSPECTION_END_DT":"03/27/2025","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2025-03-27"},{"SOURCE_ROW_NUMBER":"1046564","EVENT_NO":"7034766","INSPECTION_BEGIN_DT":"03/27/2024","INSPECTION_END_DT":"03/27/2024","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.25","SUM_TOTAL_ON_SITE_HOURS":".75","sourceDate":"2024-03-27"},{"SOURCE_ROW_NUMBER":"778550","EVENT_NO":"6307201","INSPECTION_BEGIN_DT":"07/07/2015","INSPECTION_END_DT":"07/08/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2015-07-07"},{"SOURCE_ROW_NUMBER":"252465","EVENT_NO":"6304535","INSPECTION_BEGIN_DT":"04/07/2015","INSPECTION_END_DT":"04/10/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2015-04-07"},{"SOURCE_ROW_NUMBER":"716846","EVENT_NO":"6301876","INSPECTION_BEGIN_DT":"01/12/2015","INSPECTION_END_DT":"01/20/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"37","SUM_TOTAL_ON_SITE_HOURS":"18","sourceDate":"2015-01-12"},{"SOURCE_ROW_NUMBER":"662233","EVENT_NO":"6304525","INSPECTION_BEGIN_DT":"10/03/2014","INSPECTION_END_DT":"10/14/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"21.5","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2014-10-03"},{"SOURCE_ROW_NUMBER":"1123495","EVENT_NO":"6301342","INSPECTION_BEGIN_DT":"07/09/2014","INSPECTION_END_DT":"07/09/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2014-07-09"},{"SOURCE_ROW_NUMBER":"826739","EVENT_NO":"6301340","INSPECTION_BEGIN_DT":"04/01/2014","INSPECTION_END_DT":"04/01/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2014-04-01"},{"SOURCE_ROW_NUMBER":"535502","EVENT_NO":"6303961","INSPECTION_BEGIN_DT":"01/14/2014","INSPECTION_END_DT":"01/14/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.25","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2014-01-14"},{"SOURCE_ROW_NUMBER":"48335","EVENT_NO":"6303957","INSPECTION_BEGIN_DT":"12/04/2013","INSPECTION_END_DT":"12/04/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2013-12-04"},{"SOURCE_ROW_NUMBER":"1092179","EVENT_NO":"6300712","INSPECTION_BEGIN_DT":"07/26/2013","INSPECTION_END_DT":"07/29/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2013-07-26"},{"SOURCE_ROW_NUMBER":"147386","EVENT_NO":"6301106","INSPECTION_BEGIN_DT":"04/01/2013","INSPECTION_END_DT":"04/24/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"40","SUM_TOTAL_ON_SITE_HOURS":"20.5","sourceDate":"2013-04-01"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":107,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2015-Q2":{"hours":0,"employees":0,"production":0},"2015-Q1":{"hours":0,"employees":0,"production":0},"2014-Q4":{"hours":0,"employees":0,"production":0},"2014-Q3":{"hours":0,"employees":0,"production":0},"2014-Q2":{"hours":0,"employees":0,"production":0},"2014-Q1":{"hours":0,"employees":0,"production":0},"2013-Q4":{"hours":96,"employees":1,"production":0},"2013-Q3":{"hours":96,"employees":1,"production":0},"2013-Q2":{"hours":1495,"employees":4,"production":0},"2013-Q1":{"hours":4492,"employees":21,"production":6084},"2012-Q4":{"hours":5489,"employees":21,"production":16791},"2012-Q3":{"hours":5599,"employees":20,"production":4785}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":23,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2006":{"hours":9365,"employees":11,"production":40566},"2007":{"hours":29701,"employees":15,"production":85460},"2008":{"hours":48878,"employees":25,"production":110666},"2009":{"hours":41250,"employees":19,"production":84998},"2010":{"hours":35097,"employees":16,"production":48830},"2011":{"hours":32061,"employees":15,"production":32155},"2012":{"hours":28467,"employees":20,"production":45844},"2013":{"hours":6179,"employees":13,"production":6084}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":33,"firstDate":"2007-10-17","lastDate":"2012-06-05","metrics":{"recentRows":0,"doseOver100":1,"actDoseTotal":2061,"pelDoseTotal":1430},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"256312","EVENT_NO":"6296373","SURVEY_DATE":"06/05/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"57","PEL_DOSE_90":"36","SURVEY_TYPE":"I","sourceDate":"2012-06-05"},{"SOURCE_ROW_NUMBER":"256311","EVENT_NO":"6296373","SURVEY_DATE":"06/05/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"50","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2012-06-05"},{"SOURCE_ROW_NUMBER":"256310","EVENT_NO":"6296373","SURVEY_DATE":"06/05/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"88","PEL_DOSE_90":"59","SURVEY_TYPE":"I","sourceDate":"2012-06-05"},{"SOURCE_ROW_NUMBER":"256309","EVENT_NO":"6296373","SURVEY_DATE":"06/05/2012","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"123","PEL_DOSE_90":"101","SURVEY_TYPE":"I","sourceDate":"2012-06-05"},{"SOURCE_ROW_NUMBER":"256308","EVENT_NO":"6296373","SURVEY_DATE":"06/05/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"38","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2012-06-05"},{"SOURCE_ROW_NUMBER":"256307","EVENT_NO":"6292704","SURVEY_DATE":"01/12/2011","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"42","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2011-01-12"},{"SOURCE_ROW_NUMBER":"256306","EVENT_NO":"6292704","SURVEY_DATE":"01/12/2011","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"40","PEL_DOSE_90":"18","SURVEY_TYPE":"I","sourceDate":"2011-01-12"},{"SOURCE_ROW_NUMBER":"256305","EVENT_NO":"6292704","SURVEY_DATE":"01/12/2011","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"42","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2011-01-12"},{"SOURCE_ROW_NUMBER":"256304","EVENT_NO":"6292704","SURVEY_DATE":"01/12/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"53","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2011-01-12"},{"SOURCE_ROW_NUMBER":"256303","EVENT_NO":"6292704","SURVEY_DATE":"01/12/2011","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"81","PEL_DOSE_90":"64","SURVEY_TYPE":"I","sourceDate":"2011-01-12"},{"SOURCE_ROW_NUMBER":"256302","EVENT_NO":"6287212","SURVEY_DATE":"02/23/2010","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"86","PEL_DOSE_90":"81","SURVEY_TYPE":"I","sourceDate":"2010-02-23"},{"SOURCE_ROW_NUMBER":"256301","EVENT_NO":"6287212","SURVEY_DATE":"02/23/2010","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"73","PEL_DOSE_90":"46","SURVEY_TYPE":"I","sourceDate":"2010-02-23"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":28,"firstDate":"2007-04-17","lastDate":"2012-05-16","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":12.9,"validSamples":28,"quartzPctTotal":137.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"52178","CASSETTE_NO":"57963090","SAMPLE_DT":"05/16/2012","QUARTZ_PCT":"03.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-05-16"},{"SOURCE_ROW_NUMBER":"116836","CASSETTE_NO":"51062142","SAMPLE_DT":"07/21/2010","QUARTZ_PCT":"05.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-07-21"},{"SOURCE_ROW_NUMBER":"38763","CASSETTE_NO":"51068057","SAMPLE_DT":"07/06/2010","QUARTZ_PCT":"02.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-07-06"},{"SOURCE_ROW_NUMBER":"43240","CASSETTE_NO":"57840503","SAMPLE_DT":"06/21/2010","QUARTZ_PCT":"12.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-06-21"},{"SOURCE_ROW_NUMBER":"129917","CASSETTE_NO":"57840510","SAMPLE_DT":"06/14/2010","QUARTZ_PCT":"01.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-06-14"},{"SOURCE_ROW_NUMBER":"146383","CASSETTE_NO":"57829239","SAMPLE_DT":"03/10/2010","QUARTZ_PCT":"01.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-03-10"},{"SOURCE_ROW_NUMBER":"63543","CASSETTE_NO":"57829105","SAMPLE_DT":"03/08/2010","QUARTZ_PCT":"01.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-03-08"},{"SOURCE_ROW_NUMBER":"159453","CASSETTE_NO":"51011663","SAMPLE_DT":"05/21/2009","QUARTZ_PCT":"07.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-05-21"},{"SOURCE_ROW_NUMBER":"135690","CASSETTE_NO":"51011646","SAMPLE_DT":"05/07/2009","QUARTZ_PCT":"04.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-05-07"},{"SOURCE_ROW_NUMBER":"4607","CASSETTE_NO":"57691277","SAMPLE_DT":"04/22/2009","QUARTZ_PCT":"12.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-04-22"},{"SOURCE_ROW_NUMBER":"102183","CASSETTE_NO":"57691578","SAMPLE_DT":"04/20/2009","QUARTZ_PCT":"02.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-04-20"},{"SOURCE_ROW_NUMBER":"51357","CASSETTE_NO":"57691414","SAMPLE_DT":"03/11/2009","QUARTZ_PCT":"01.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-03-11"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":305,"firstDate":"2007-02-06","lastDate":"2015-01-13","metrics":{"ss":82,"amountDue":99237,"contested":1,"amountPaid":99237,"recentRows":0,"section104d":4,"unterminated":1,"proposedPenalty":114537},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2891556","VIOLATION_NO":"9062680","VIOLATION_ISSUE_DT":"01/13/2015","SIG_SUB":"N","PART_SECTION":"77.1911(b)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/14/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-01-13"},{"SOURCE_ROW_NUMBER":"2891742","VIOLATION_NO":"9020181","VIOLATION_ISSUE_DT":"10/03/2014","SIG_SUB":"N","PART_SECTION":"75.1722(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/14/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-10-03"},{"SOURCE_ROW_NUMBER":"2891741","VIOLATION_NO":"7196242","VIOLATION_ISSUE_DT":"11/20/2012","SIG_SUB":"N","PART_SECTION":"75.900-4","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/20/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-11-20"},{"SOURCE_ROW_NUMBER":"2891740","VIOLATION_NO":"7196241","VIOLATION_ISSUE_DT":"11/20/2012","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)(ii)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/20/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-11-20"},{"SOURCE_ROW_NUMBER":"2891739","VIOLATION_NO":"7196240","VIOLATION_ISSUE_DT":"11/19/2012","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/19/2012","PROPOSED_PENALTY":"499","AMOUNT_DUE":"499","AMOUNT_PAID":"499","CONTESTED_IND":"N","sourceDate":"2012-11-19"},{"SOURCE_ROW_NUMBER":"2891738","VIOLATION_NO":"7196239","VIOLATION_ISSUE_DT":"11/15/2012","SIG_SUB":"N","PART_SECTION":"75.515","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/15/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-11-15"},{"SOURCE_ROW_NUMBER":"2891737","VIOLATION_NO":"7196238","VIOLATION_ISSUE_DT":"11/15/2012","SIG_SUB":"Y","PART_SECTION":"75.1731(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/15/2012","PROPOSED_PENALTY":"460","AMOUNT_DUE":"460","AMOUNT_PAID":"460","CONTESTED_IND":"N","sourceDate":"2012-11-15"},{"SOURCE_ROW_NUMBER":"2891736","VIOLATION_NO":"7196237","VIOLATION_ISSUE_DT":"11/15/2012","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/15/2012","PROPOSED_PENALTY":"1304","AMOUNT_DUE":"1304","AMOUNT_PAID":"1304","CONTESTED_IND":"N","sourceDate":"2012-11-15"},{"SOURCE_ROW_NUMBER":"2891735","VIOLATION_NO":"7196235","VIOLATION_ISSUE_DT":"10/29/2012","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/15/2012","PROPOSED_PENALTY":"243","AMOUNT_DUE":"243","AMOUNT_PAID":"243","CONTESTED_IND":"N","sourceDate":"2012-10-29"},{"SOURCE_ROW_NUMBER":"2891734","VIOLATION_NO":"7196234","VIOLATION_ISSUE_DT":"10/29/2012","SIG_SUB":"N","PART_SECTION":"75.605","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/29/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-10-29"},{"SOURCE_ROW_NUMBER":"2891733","VIOLATION_NO":"7196233","VIOLATION_ISSUE_DT":"10/29/2012","SIG_SUB":"N","PART_SECTION":"75.604(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/29/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-10-29"},{"SOURCE_ROW_NUMBER":"2891732","VIOLATION_NO":"7196232","VIOLATION_ISSUE_DT":"10/29/2012","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/15/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-10-29"}]}],"safety":{"href":"/api/v1/mines/4609129/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609129/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Ventilation of slopes and shafts.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-T/section-77.1911","part":"77","subchapter":"O","subpart":"T","id":"77.1911","citation":"30 CFR 77.1911","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1722","heading":"Mechanical equipment guards.","id":"75.1722","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1722","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","heading":"Testing, examination, and maintenance of circuit breakers; record.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-J/section-75.900-4","part":"75","subchapter":"O","subpart":"J","id":"75.900-4","citation":"30 CFR 75.900-4","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1725","heading":"Machinery and equipment; operation and maintenance.","id":"75.1725","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1725","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.515","heading":"Cable fittings; suitability.","id":"75.515","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.515","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nCables shall enter metal frames of motors, splice boxes, and electric compartments only through proper fittings. When insulated wires other than cables pass through metal frames, the holes shall be substantially bushed with insulated bushings.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1731","heading":"Maintenance of belt conveyors and belt conveyor entries.","id":"75.1731","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1731","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Damaged rollers, or other damaged belt conveyor components, which pose a fire hazard must be immediately repaired or replaced. All other damaged rollers, or other damaged belt conveyor components, must be repaired or replaced.\n\n(b) Conveyor belts must be properly aligned to prevent the moving belt from rubbing against the structure or components.\n\n(c) Materials shall not be allowed in the belt conveyor entry where the material may contribute to a frictional heating hazard.\n\n(d) Splicing of any approved conveyor belt must maintain flame-resistant properties of the belt.\n\n[73 FR 80616, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":2},{"chapter":"I","heading":"Clamping of trailing cables to equipment.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.605","part":"75","subchapter":"O","subpart":"G","id":"75.605","citation":"30 CFR 75.605","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.604","heading":"Permanent splicing of trailing cables.","id":"75.604","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.604","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"[Statutory Provisions]\n\nWhen permanent splices in trailing cables are made, they shall be:\n\n(a) Mechanically strong with adequate electrical conductivity and flexibility;\n\n(b) Effectively insulated and sealed so as to exclude moisture; and\n\n(c) Vulcanized or otherwise treated with suitable materials to provide flame-resistant qualities and good bonding to the outer jacket.\n\n(d) Made using splice kits accepted or approved by MSHA as flame resistant.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 57 FR 61223, Dec. 23, 1992]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609129","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}