{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4609110","name":"No. 10","status":"Abandoned and Sealed","status_date":"2007-06-29","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Mingo","nearest_town":"Gilbert","operator_id":"P24390","operator_name":"Rockhouse Creek Development Corp.","controller_id":"C13562","controller_name":"James River Coal Company","district":"C04","office":"Beckley District","employees":0,"latitude":37.583888,"longitude":-81.888333},"coverage":{"contributingSources":15,"registeredSources":20,"sourceRows":175},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609110","name":"No. 10"},"operator":{"type":"operator","id":"P24390","name":"Rockhouse Creek Development Corp."},"controller":{"type":"controller","id":"C13562","name":"James River Coal Company"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13442","name":"International Industries Inc"},"object":{"type":"mine","id":"4609110","name":"No. 10"},"validFrom":"1977-07-01","validTo":"2007-07-19","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609110|C13442|1977-07-01|2007-07-19"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13442","name":"International Industries Inc"},"object":{"type":"mine","id":"4609110","name":"No. 10"},"validFrom":"1999-06-01","validTo":"2007-07-15","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609110|C13442|1999-06-01|2007-07-15"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22053","name":"Chafin Branch Coal Company"},"object":{"type":"mine","id":"4609110","name":"No. 10"},"validFrom":"2005-07-10","validTo":"2005-08-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609110|P22053|2005-07-10|2005-08-31"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13442","name":"International Industries Inc"},"object":{"type":"operator","id":"P22053","name":"Chafin Branch Coal Company"},"validFrom":"2005-07-10","validTo":"2005-08-31","current":false,"derived":true,"evidenceMineId":"4609110","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609110|P22053|2005-07-10|C13442|1977-07-01|89988"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0063644","name":"Newborn Contracting, Inc."},"object":{"type":"mine","id":"4609110","name":"No. 10"},"validFrom":"2005-09-01","validTo":"2006-07-11","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609110|0063644|2005-09-01|2006-07-11"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0053231","name":"Donnie R  Boren"},"object":{"type":"mine","id":"4609110","name":"No. 10"},"validFrom":"2005-09-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609110|0053231|2005-09-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0053231","name":"Donnie R  Boren"},"object":{"type":"operator","id":"0063644","name":"Newborn Contracting, Inc."},"validFrom":"2005-09-01","validTo":"2006-07-11","current":false,"derived":true,"evidenceMineId":"4609110","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609110|0063644|2005-09-01|0053231|2005-09-01|6795"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24390","name":"Rockhouse Creek Development Corp."},"object":{"type":"mine","id":"4609110","name":"No. 10"},"validFrom":"2006-07-12","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609110|P24390|2006-07-12|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13442","name":"International Industries Inc"},"object":{"type":"operator","id":"P24390","name":"Rockhouse Creek Development Corp."},"validFrom":"2006-07-12","validTo":"2007-07-15","current":false,"derived":true,"evidenceMineId":"4609110","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609110|P24390|2006-07-12|C13442|1999-06-01|90015"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0069031","name":"International Resources LLC"},"object":{"type":"mine","id":"4609110","name":"No. 10"},"validFrom":"2007-07-16","validTo":"2011-04-17","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609110|0069031|2007-07-16|2011-04-17"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0069031","name":"International Resources LLC"},"object":{"type":"operator","id":"P24390","name":"Rockhouse Creek Development Corp."},"validFrom":"2007-07-16","validTo":"2011-04-17","current":false,"derived":true,"evidenceMineId":"4609110","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609110|P24390|2006-07-12|0069031|2007-07-16|9765"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0069031","name":"International Resources LLC"},"object":{"type":"mine","id":"4609110","name":"No. 10"},"validFrom":"2007-07-20","validTo":"2011-04-17","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609110|0069031|2007-07-20|2011-04-17"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0069031","name":"International Resources LLC"},"object":{"type":"operator","id":"P22053","name":"Chafin Branch Coal Company"},"validFrom":"2007-07-20","validTo":"2005-08-31","current":false,"derived":true,"evidenceMineId":"4609110","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609110|P22053|2005-07-10|0069031|2007-07-20|9777"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"mine","id":"4609110","name":"No. 10"},"validFrom":"2011-04-18","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609110|C13562|2011-04-18|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"operator","id":"P22053","name":"Chafin Branch Coal Company"},"validFrom":"2011-04-18","validTo":"2005-08-31","current":false,"derived":true,"evidenceMineId":"4609110","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609110|P22053|2005-07-10|C13562|2011-04-18|90494"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"operator","id":"P24390","name":"Rockhouse Creek Development Corp."},"validFrom":"2011-04-18","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609110","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609110|P24390|2006-07-12|C13562|2011-04-18|90495"}}],"coverage":{"historyRecords":7,"edgeCount":16,"intervalAnomalies":2,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":9,"firstDate":"2006-02-13","lastDate":"2007-03-27","metrics":{"daysLost":656,"injuries":7,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"51240","DOCUMENT_NO":"220070920058","ACCIDENT_DT":"03/27/2007","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was removing bolts from a structure when a piece of draw rock fell hitting him on rt side of neck and shoulder.","sourceDate":"2007-03-27"},{"SOURCE_ROW_NUMBER":"244935","DOCUMENT_NO":"220070540052","ACCIDENT_DT":"02/05/2007","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"No one was injured or any equipment involved. We have soft top conditions and low cover in this area. No cracks or water was present in this area during normal mining procedures.","sourceDate":"2007-02-05"},{"SOURCE_ROW_NUMBER":"210463","DOCUMENT_NO":"220070090023","ACCIDENT_DT":"01/02/2007","DEGREE_INJURY":"PERM TOT OR PERM PRTL DISABLTY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"33","NARRATIVE":"Employee was putting pusher & finisher together caught left index finger between steel, pinching end of finer off.","sourceDate":"2007-01-02"},{"SOURCE_ROW_NUMBER":"262200","DOCUMENT_NO":"220062890116","ACCIDENT_DT":"10/11/2006","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Unplanned roof fall in return entry. Area cribbed and dangered off to prevent entrance by fellow employees. Fall was approximately 18' wide by 30 ' long and 3' to 4' thick.","sourceDate":"2006-10-11"},{"SOURCE_ROW_NUMBER":"274898","DOCUMENT_NO":"220062120091","ACCIDENT_DT":"07/22/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"6","NARRATIVE":"Employee was bolting top in the #3 entry. He went to bend the roof bolt and pulled lower back.","sourceDate":"2006-07-22"},{"SOURCE_ROW_NUMBER":"81426","DOCUMENT_NO":"220061630073","ACCIDENT_DT":"05/30/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"261","NARRATIVE":"Employee bolting top when bolting operator being performed a piece of draw rock fell striking ee on left foot, lower back and top of head.","sourceDate":"2006-05-30"},{"SOURCE_ROW_NUMBER":"154537","DOCUMENT_NO":"220061500050","ACCIDENT_DT":"05/15/2006","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"bolting top in #7 hdg., piece of draw rock fell hitting ee on back of neck and forearm. (Contusion)","sourceDate":"2006-05-15"},{"SOURCE_ROW_NUMBER":"16858","DOCUMENT_NO":"220060720080","ACCIDENT_DT":"03/03/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"21","NARRATIVE":"Had left hand outside operator compartment and on rubber bumper block. Steered scoop and caught fingers between bumper block and frame of scoop.","sourceDate":"2006-03-03"},{"SOURCE_ROW_NUMBER":"219119","DOCUMENT_NO":"220060550028","ACCIDENT_DT":"02/13/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter helper, Rock bolter helper, Pinner helper","NO_INJURIES":"1","DAYS_LOST":"335","NARRATIVE":"Bolting top, small piece of draw rock approximately 15\" square - 1 1/2\" to 2\" thick fell and hit employee on lower back.","sourceDate":"2006-02-13"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2007-06-29","lastDate":"2007-06-29","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":28,"firstDate":"2006-01-10","lastDate":"2007-02-05","metrics":{"ss":7,"delinquent":28,"recentRows":0,"paidPenalty":2211,"proposedPenalty":2649,"currentAssessment":2211},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"825092","VIOLATION_NO":"7264446","ISSUE_DT":"02/05/2007","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"838.00","CURRENT_ASSESSMENT_AMT":"400.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-02-05"},{"SOURCE_ROW_NUMBER":"820448","VIOLATION_NO":"7248890","ISSUE_DT":"01/12/2007","CFR_STANDARD_CD":"75.1101-6","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-01-12"},{"SOURCE_ROW_NUMBER":"820447","VIOLATION_NO":"7248889","ISSUE_DT":"01/12/2007","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-01-12"},{"SOURCE_ROW_NUMBER":"820442","VIOLATION_NO":"7248881","ISSUE_DT":"10/30/2006","CFR_STANDARD_CD":"75.333(d)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-10-30"},{"SOURCE_ROW_NUMBER":"820441","VIOLATION_NO":"7248880","ISSUE_DT":"10/24/2006","CFR_STANDARD_CD":"75.1714-3(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-10-24"},{"SOURCE_ROW_NUMBER":"820440","VIOLATION_NO":"7248879","ISSUE_DT":"10/24/2006","CFR_STANDARD_CD":"75.400-2","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-10-24"},{"SOURCE_ROW_NUMBER":"820439","VIOLATION_NO":"7248878","ISSUE_DT":"10/24/2006","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-10-24"},{"SOURCE_ROW_NUMBER":"820438","VIOLATION_NO":"7248877","ISSUE_DT":"10/24/2006","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"124.00","CURRENT_ASSESSMENT_AMT":"124.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-10-24"},{"SOURCE_ROW_NUMBER":"820437","VIOLATION_NO":"7248876","ISSUE_DT":"10/24/2006","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-10-24"},{"SOURCE_ROW_NUMBER":"820436","VIOLATION_NO":"7248875","ISSUE_DT":"10/24/2006","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"135.00","CURRENT_ASSESSMENT_AMT":"135.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-10-24"},{"SOURCE_ROW_NUMBER":"820435","VIOLATION_NO":"7248874","ISSUE_DT":"10/24/2006","CFR_STANDARD_CD":"75.1002(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-10-24"},{"SOURCE_ROW_NUMBER":"820434","VIOLATION_NO":"7248873","ISSUE_DT":"10/24/2006","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-10-24"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":1,"firstDate":"2009-07-28","lastDate":"2009-07-28","metrics":{"appeals":0,"decisions":1,"recentRows":0,"decisionPenalty":400,"originalPenalty":838},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"216654","VIOLATION_NO":"7264446","DOCKET_NO":"WEVA 2008-1023","DECISION_DT":"07/28/2009","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"838.00","DECISION_PENALTY_AMT":"400.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2009-07-28"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":63,"firstDate":"2006-01-11","lastDate":"2007-03-28","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":1,"validSamples":62,"maxConcentration":5.098,"concentrationTotal":67.982},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"142436","CASS_NUM":"50898952","SMP_TAKEN_DT":"3/28/2007","CONC":".386","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-03-28"},{"SOURCE_ROW_NUMBER":"100661","CASS_NUM":"50898926","SMP_TAKEN_DT":"3/27/2007","CONC":"1.177","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-03-27"},{"SOURCE_ROW_NUMBER":"607657","CASS_NUM":"50898899","SMP_TAKEN_DT":"3/26/2007","CONC":"2.511","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-03-26"},{"SOURCE_ROW_NUMBER":"90807","CASS_NUM":"50898925","SMP_TAKEN_DT":"3/23/2007","CONC":"1.851","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-03-23"},{"SOURCE_ROW_NUMBER":"1347999","CASS_NUM":"50898916","SMP_TAKEN_DT":"3/22/2007","CONC":".756","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-03-22"},{"SOURCE_ROW_NUMBER":"330434","CASS_NUM":"50898948","SMP_TAKEN_DT":"3/20/2007","CONC":"1.102","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-03-20"},{"SOURCE_ROW_NUMBER":"1553810","CASS_NUM":"50892560","SMP_TAKEN_DT":"1/25/2007","CONC":".099","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-01-25"},{"SOURCE_ROW_NUMBER":"621800","CASS_NUM":"50892598","SMP_TAKEN_DT":"1/22/2007","CONC":".211","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-01-22"},{"SOURCE_ROW_NUMBER":"1247614","CASS_NUM":"50892590","SMP_TAKEN_DT":"1/19/2007","CONC":"1.597","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-01-19"},{"SOURCE_ROW_NUMBER":"1662835","CASS_NUM":"50892581","SMP_TAKEN_DT":"1/17/2007","CONC":".28","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-01-17"},{"SOURCE_ROW_NUMBER":"59963","CASS_NUM":"50892597","SMP_TAKEN_DT":"1/16/2007","CONC":".468","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-01-16"},{"SOURCE_ROW_NUMBER":"929166","CASS_NUM":"50892606","SMP_TAKEN_DT":"1/15/2007","CONC":".388","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-01-15"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":3,"firstDate":"2007-01-30","lastDate":"2007-02-15","metrics":{"linkedIssuances":3},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":1,"firstDate":"2007-02-05","lastDate":"2007-02-05","metrics":{"decisions":1,"ssChanged":0,"recentRows":0,"decisionPenalty":400,"proposedPenalty":838},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"229650","CITATION_NO":"7264446","CITATION_ISSUE_DT":"02/05/2007","DOCKET_NO":"WEVA 2008-1023","DECISION_DT":"07/28/2009","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"838.00","DECISION_PENALTY_AMT":"400.00","sourceDate":"2007-02-05"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":7,"firstDate":"2005-07-10","lastDate":"2006-07-12","metrics":{"recentRows":0,"currentOperatorTenures":3,"completedOperatorTenures":4},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":8,"firstDate":"2006-01-09","lastDate":"2007-06-27","metrics":{"inspectors":8,"recentRows":0,"onSiteHours":192.75,"inspectionHours":345.5,"inspectionSamples":38},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"318410","EVENT_NO":"4113892","INSPECTION_BEGIN_DT":"06/27/2007","INSPECTION_END_DT":"06/28/2007","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2007-06-27"},{"SOURCE_ROW_NUMBER":"263291","EVENT_NO":"4113888","INSPECTION_BEGIN_DT":"05/22/2007","INSPECTION_END_DT":"05/22/2007","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2007-05-22"},{"SOURCE_ROW_NUMBER":"825158","EVENT_NO":"4115124","INSPECTION_BEGIN_DT":"02/05/2007","INSPECTION_END_DT":"02/08/2007","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"19.5","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2007-02-05"},{"SOURCE_ROW_NUMBER":"424310","EVENT_NO":"4113876","INSPECTION_BEGIN_DT":"01/12/2007","INSPECTION_END_DT":"01/25/2007","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"55","SUM_TOTAL_ON_SITE_HOURS":"32.5","sourceDate":"2007-01-12"},{"SOURCE_ROW_NUMBER":"877690","EVENT_NO":"4113873","INSPECTION_BEGIN_DT":"10/24/2006","INSPECTION_END_DT":"11/27/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"90","SUM_TOTAL_ON_SITE_HOURS":"53.5","sourceDate":"2006-10-24"},{"SOURCE_ROW_NUMBER":"317468","EVENT_NO":"4115256","INSPECTION_BEGIN_DT":"07/05/2006","INSPECTION_END_DT":"08/10/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"78","SUM_TOTAL_ON_SITE_HOURS":"37.75","sourceDate":"2006-07-05"},{"SOURCE_ROW_NUMBER":"826232","EVENT_NO":"4106293","INSPECTION_BEGIN_DT":"04/04/2006","INSPECTION_END_DT":"06/29/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"54","SUM_TOTAL_ON_SITE_HOURS":"33","sourceDate":"2006-04-04"},{"SOURCE_ROW_NUMBER":"859538","EVENT_NO":"4106286","INSPECTION_BEGIN_DT":"01/09/2006","INSPECTION_END_DT":"01/18/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"37","SUM_TOTAL_ON_SITE_HOURS":"24","sourceDate":"2006-01-09"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":10,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2007-Q1":{"hours":22485,"employees":41,"production":36859},"2006-Q4":{"hours":22756,"employees":41,"production":33719},"2006-Q3":{"hours":23794,"employees":35,"production":23794},"2006-Q2":{"hours":9298,"employees":13,"production":16299},"2006-Q1":{"hours":7308,"employees":10,"production":17089},"2005-Q4":{"hours":3854,"employees":7,"production":4631},"2005-Q3":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":5,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2005":{"hours":3854,"employees":7,"production":4631},"2006":{"hours":63156,"employees":26,"production":90901},"2007":{"hours":22485,"employees":41,"production":36859}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":7,"firstDate":"2006-07-20","lastDate":"2006-07-20","metrics":{"recentRows":0,"doseOver100":0,"actDoseTotal":365,"pelDoseTotal":226},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"255753","EVENT_NO":"4115256","SURVEY_DATE":"07/20/2006","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"57","PEL_DOSE_90":"34","SURVEY_TYPE":"I","sourceDate":"2006-07-20"},{"SOURCE_ROW_NUMBER":"255752","EVENT_NO":"4115256","SURVEY_DATE":"07/20/2006","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"38","PEL_DOSE_90":"20","SURVEY_TYPE":"I","sourceDate":"2006-07-20"},{"SOURCE_ROW_NUMBER":"255751","EVENT_NO":"4115256","SURVEY_DATE":"07/20/2006","OCCUPATION_CD_DESC":"CONTINUOUS MINER HELPER","MACHINE_CD":"06","MANUFACTURER_CD":"033","ACT_DOSE_85":"28","PEL_DOSE_90":"18","SURVEY_TYPE":"I","sourceDate":"2006-07-20"},{"SOURCE_ROW_NUMBER":"255750","EVENT_NO":"4115256","SURVEY_DATE":"07/20/2006","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"033","ACT_DOSE_85":"60","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2006-07-20"},{"SOURCE_ROW_NUMBER":"255749","EVENT_NO":"4115256","SURVEY_DATE":"07/20/2006","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"38","PEL_DOSE_90":"18","SURVEY_TYPE":"I","sourceDate":"2006-07-20"},{"SOURCE_ROW_NUMBER":"255748","EVENT_NO":"4115256","SURVEY_DATE":"07/20/2006","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"81","PEL_DOSE_90":"55","SURVEY_TYPE":"I","sourceDate":"2006-07-20"},{"SOURCE_ROW_NUMBER":"255747","EVENT_NO":"4115256","SURVEY_DATE":"07/20/2006","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"63","PEL_DOSE_90":"37","SURVEY_TYPE":"I","sourceDate":"2006-07-20"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":2,"firstDate":"2006-06-12","lastDate":"2006-10-31","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":8,"validSamples":2,"quartzPctTotal":13},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"16110","CASSETTE_NO":"57630501","SAMPLE_DT":"10/31/2006","QUARTZ_PCT":"05.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-10-31"},{"SOURCE_ROW_NUMBER":"138001","CASSETTE_NO":"57630337","SAMPLE_DT":"06/12/2006","QUARTZ_PCT":"08.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-06-12"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":29,"firstDate":"2006-01-10","lastDate":"2007-02-05","metrics":{"ss":7,"amountDue":2211,"contested":1,"amountPaid":2211,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":2649},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2889576","VIOLATION_NO":"7264447","VIOLATION_ISSUE_DT":"02/05/2007","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"02/06/2007","CONTESTED_IND":"N","sourceDate":"2007-02-05"},{"SOURCE_ROW_NUMBER":"2889575","VIOLATION_NO":"7264446","VIOLATION_ISSUE_DT":"02/05/2007","SIG_SUB":"Y","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/06/2007","PROPOSED_PENALTY":"838","AMOUNT_DUE":"400","AMOUNT_PAID":"400","CONTESTED_IND":"Y","DOCKET_NO":"WEVA 2008-1023","sourceDate":"2007-02-05"},{"SOURCE_ROW_NUMBER":"2889574","VIOLATION_NO":"7248890","VIOLATION_ISSUE_DT":"01/12/2007","SIG_SUB":"N","PART_SECTION":"75.1101-6","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/12/2007","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2007-01-12"},{"SOURCE_ROW_NUMBER":"2889573","VIOLATION_NO":"7248889","VIOLATION_ISSUE_DT":"01/12/2007","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/12/2007","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2007-01-12"},{"SOURCE_ROW_NUMBER":"2889596","VIOLATION_NO":"7248881","VIOLATION_ISSUE_DT":"10/30/2006","SIG_SUB":"N","PART_SECTION":"75.333(d)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/07/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-10-30"},{"SOURCE_ROW_NUMBER":"2889595","VIOLATION_NO":"7248880","VIOLATION_ISSUE_DT":"10/24/2006","SIG_SUB":"N","PART_SECTION":"75.1714-3(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"12","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/25/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-10-24"},{"SOURCE_ROW_NUMBER":"2889594","VIOLATION_NO":"7248879","VIOLATION_ISSUE_DT":"10/24/2006","SIG_SUB":"N","PART_SECTION":"75.400-2","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"5","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/25/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-10-24"},{"SOURCE_ROW_NUMBER":"2889593","VIOLATION_NO":"7248878","VIOLATION_ISSUE_DT":"10/24/2006","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/25/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-10-24"},{"SOURCE_ROW_NUMBER":"2889592","VIOLATION_NO":"7248877","VIOLATION_ISSUE_DT":"10/24/2006","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/24/2006","PROPOSED_PENALTY":"124","AMOUNT_DUE":"124","AMOUNT_PAID":"124","CONTESTED_IND":"N","sourceDate":"2006-10-24"},{"SOURCE_ROW_NUMBER":"2889591","VIOLATION_NO":"7248876","VIOLATION_ISSUE_DT":"10/24/2006","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/25/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-10-24"},{"SOURCE_ROW_NUMBER":"2889590","VIOLATION_NO":"7248875","VIOLATION_ISSUE_DT":"10/24/2006","SIG_SUB":"Y","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/24/2006","PROPOSED_PENALTY":"135","AMOUNT_DUE":"135","AMOUNT_PAID":"135","CONTESTED_IND":"N","sourceDate":"2006-10-24"},{"SOURCE_ROW_NUMBER":"2889589","VIOLATION_NO":"7248874","VIOLATION_ISSUE_DT":"10/24/2006","SIG_SUB":"N","PART_SECTION":"75.1002(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/24/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-10-24"}]}],"safety":{"href":"/api/v1/mines/4609110/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609110/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":2},{"chapter":"I","heading":"Water sprinkler systems; general.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1101-6","part":"75","subchapter":"O","subpart":"L","id":"75.1101-6","citation":"30 CFR 75.1101-6","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","heading":"Self-rescue devices; inspection, testing, maintenance, repair, and recordkeeping.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-3","part":"75","subchapter":"O","subpart":"R","id":"75.1714-3","citation":"30 CFR 75.1714-3","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Cleanup program.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400-2","part":"75","subchapter":"O","subpart":"E","id":"75.400-2","citation":"30 CFR 75.400-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1002","heading":"Installation of electric equipment and conductors; permissibility.","id":"75.1002","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-K/section-75.1002","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"K","subpartHeading":"Subpart K—Trolley Wires and Trolley Feeder Wires","text":"(a) Electric equipment must be permissible and maintained in a permissible condition when such equipment is located within 150 feet of pillar workings or longwall faces.\n\n(b) Electric conductors and cables installed in or in by the last open crosscut or within 150 feet of pillar workings or longwall faces must be—\n\n(1) Shielded high-voltage cables supplying power to permissible longwall equipment;\n\n(2) Interconnecting conductors and cables of permissible longwall equipment;\n\n(3) Conductors and cables of intrinsically safe circuits; and\n\n(4) Cables and conductors supplying power to low- and medium-voltage permissible equipment.\n\n(5) Shielded high-voltage cables supplying power to permissible continuous mining machines.\n\n[67 FR 11004, Mar. 11, 2002, as amended at 75 FR 17553, Apr. 6, 2010]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609110","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}