{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4609104","name":"Still Run No. 10","status":"Abandoned and Sealed","status_date":"2009-06-16","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Wyoming","nearest_town":"Itmann","operator_id":"P24515","operator_name":"Richmond Works Inc","controller_id":"C15988","controller_name":"Timothy  Lester","district":"C04","office":"Beckley District","employees":0,"latitude":37.586666,"longitude":-81.421944},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":616},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609104","name":"Still Run No. 10"},"operator":{"type":"operator","id":"P24515","name":"Richmond Works Inc"},"controller":{"type":"controller","id":"C15988","name":"Timothy  Lester"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15988","name":"Timothy  Lester"},"object":{"type":"mine","id":"4609104","name":"Still Run No. 10"},"validFrom":"2000-12-21","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609104|C15988|2000-12-21|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24515","name":"Richmond Works Inc"},"object":{"type":"mine","id":"4609104","name":"Still Run No. 10"},"validFrom":"2005-05-12","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609104|P24515|2005-05-12|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15988","name":"Timothy  Lester"},"object":{"type":"operator","id":"P24515","name":"Richmond Works Inc"},"validFrom":"2005-05-12","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609104","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609104|P24515|2005-05-12|C15988|2000-12-21|97928"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":1,"firstDate":"2008-09-22","lastDate":"2008-09-22","metrics":{"daysLost":0,"injuries":0,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"85683","DOCUMENT_NO":"220082760050","ACCIDENT_DT":"09/22/2008","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Rock fall in # 7 entry","sourceDate":"2008-09-22"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2009-06-16","lastDate":"2009-06-16","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":136,"firstDate":"2006-02-06","lastDate":"2008-08-27","metrics":{"ss":46,"delinquent":136,"recentRows":0,"paidPenalty":14160.88,"proposedPenalty":90142,"currentAssessment":90142},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"870783","VIOLATION_NO":"6622740","ISSUE_DT":"08/27/2008","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"150.00","CURRENT_ASSESSMENT_AMT":"150.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-08-27"},{"SOURCE_ROW_NUMBER":"870782","VIOLATION_NO":"6622739","ISSUE_DT":"08/27/2008","CFR_STANDARD_CD":"77.1710(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-08-27"},{"SOURCE_ROW_NUMBER":"870784","VIOLATION_NO":"6622741","ISSUE_DT":"08/26/2008","CFR_STANDARD_CD":"77.1606(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-08-26"},{"SOURCE_ROW_NUMBER":"870781","VIOLATION_NO":"6622738","ISSUE_DT":"08/26/2008","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1412.00","CURRENT_ASSESSMENT_AMT":"1412.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-08-26"},{"SOURCE_ROW_NUMBER":"870780","VIOLATION_NO":"6622737","ISSUE_DT":"08/26/2008","CFR_STANDARD_CD":"75.1103-4(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"634.00","CURRENT_ASSESSMENT_AMT":"634.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-08-26"},{"SOURCE_ROW_NUMBER":"870779","VIOLATION_NO":"6622736","ISSUE_DT":"08/26/2008","CFR_STANDARD_CD":"77.1606(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-08-26"},{"SOURCE_ROW_NUMBER":"870778","VIOLATION_NO":"6622735","ISSUE_DT":"08/26/2008","CFR_STANDARD_CD":"77.1606(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-08-26"},{"SOURCE_ROW_NUMBER":"870798","VIOLATION_NO":"7266964","ISSUE_DT":"08/13/2008","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"499.00","CURRENT_ASSESSMENT_AMT":"499.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-08-13"},{"SOURCE_ROW_NUMBER":"870797","VIOLATION_NO":"7266963","ISSUE_DT":"08/13/2008","CFR_STANDARD_CD":"75.515","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"362.00","CURRENT_ASSESSMENT_AMT":"362.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-08-13"},{"SOURCE_ROW_NUMBER":"870796","VIOLATION_NO":"7266962","ISSUE_DT":"08/13/2008","CFR_STANDARD_CD":"75.1722(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"425.00","CURRENT_ASSESSMENT_AMT":"425.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-08-13"},{"SOURCE_ROW_NUMBER":"870795","VIOLATION_NO":"7266961","ISSUE_DT":"08/13/2008","CFR_STANDARD_CD":"75.1101-7(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"499.00","CURRENT_ASSESSMENT_AMT":"499.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-08-13"},{"SOURCE_ROW_NUMBER":"870794","VIOLATION_NO":"7266960","ISSUE_DT":"08/13/2008","CFR_STANDARD_CD":"75.516-2(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-08-13"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":29,"firstDate":"2010-07-19","lastDate":"2011-01-04","metrics":{"appeals":0,"decisions":29,"recentRows":0,"decisionPenalty":50123,"originalPenalty":50123},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"233272","VIOLATION_NO":"6622737","DOCKET_NO":"WEVA 2009-354","DECISION_DT":"01/04/2011","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"634.00","DECISION_PENALTY_AMT":"634.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2011-01-04"},{"SOURCE_ROW_NUMBER":"31184","VIOLATION_NO":"6622738","DOCKET_NO":"WEVA 2009-354","DECISION_DT":"01/04/2011","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"1412.00","DECISION_PENALTY_AMT":"1412.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2011-01-04"},{"SOURCE_ROW_NUMBER":"227185","VIOLATION_NO":"7266949","DOCKET_NO":"WEVA 2008-1851","DECISION_DT":"08/11/2010","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"3405.00","DECISION_PENALTY_AMT":"3405.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2010-08-11"},{"SOURCE_ROW_NUMBER":"227184","VIOLATION_NO":"7266948","DOCKET_NO":"WEVA 2008-1851","DECISION_DT":"08/11/2010","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"6458.00","DECISION_PENALTY_AMT":"6458.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2010-08-11"},{"SOURCE_ROW_NUMBER":"227183","VIOLATION_NO":"6616543","DOCKET_NO":"WEVA 2008-1851","DECISION_DT":"08/11/2010","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"7176.00","DECISION_PENALTY_AMT":"7176.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2010-08-11"},{"SOURCE_ROW_NUMBER":"227182","VIOLATION_NO":"6616534","DOCKET_NO":"WEVA 2008-1851","DECISION_DT":"08/11/2010","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"6458.00","DECISION_PENALTY_AMT":"6458.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2010-08-11"},{"SOURCE_ROW_NUMBER":"227139","VIOLATION_NO":"6616541","DOCKET_NO":"WEVA 2008-1851","DECISION_DT":"08/11/2010","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"7176.00","DECISION_PENALTY_AMT":"7176.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2010-08-11"},{"SOURCE_ROW_NUMBER":"227138","VIOLATION_NO":"6616532","DOCKET_NO":"WEVA 2008-1851","DECISION_DT":"08/11/2010","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"2000.00","DECISION_PENALTY_AMT":"2000.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2010-08-11"},{"SOURCE_ROW_NUMBER":"227137","VIOLATION_NO":"6616523","DOCKET_NO":"WEVA 2008-1851","DECISION_DT":"08/11/2010","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"946.00","DECISION_PENALTY_AMT":"946.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2010-08-11"},{"SOURCE_ROW_NUMBER":"226416","VIOLATION_NO":"6616525","DOCKET_NO":"WEVA 2008-1851","DECISION_DT":"08/11/2010","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"634.00","DECISION_PENALTY_AMT":"634.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2010-08-11"},{"SOURCE_ROW_NUMBER":"226054","VIOLATION_NO":"6616533","DOCKET_NO":"WEVA 2008-1851","DECISION_DT":"08/11/2010","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"2000.00","DECISION_PENALTY_AMT":"2000.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2010-08-11"},{"SOURCE_ROW_NUMBER":"226053","VIOLATION_NO":"6616528","DOCKET_NO":"WEVA 2008-1851","DECISION_DT":"08/11/2010","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"946.00","DECISION_PENALTY_AMT":"946.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2010-08-11"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":123,"firstDate":"2006-02-08","lastDate":"2008-08-27","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":9,"validSamples":114,"maxConcentration":6.116,"concentrationTotal":88.99},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1383263","CASS_NUM":"57737715","SMP_TAKEN_DT":"8/27/2008","CONC":".324","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-08-27"},{"SOURCE_ROW_NUMBER":"1345594","CASS_NUM":"57737735","SMP_TAKEN_DT":"8/27/2008","CONC":".736","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-08-27"},{"SOURCE_ROW_NUMBER":"1139871","CASS_NUM":"57737716","SMP_TAKEN_DT":"8/27/2008","CONC":".162","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SECTION FOREMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-08-27"},{"SOURCE_ROW_NUMBER":"1109773","CASS_NUM":"57737652","SMP_TAKEN_DT":"8/27/2008","CONC":".142","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-08-27"},{"SOURCE_ROW_NUMBER":"874272","CASS_NUM":"57737664","SMP_TAKEN_DT":"8/27/2008","CONC":".274","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-08-27"},{"SOURCE_ROW_NUMBER":"127410","CASS_NUM":"57737673","SMP_TAKEN_DT":"8/27/2008","CONC":".265","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-08-27"},{"SOURCE_ROW_NUMBER":"1263207","CASS_NUM":"50945854","SMP_TAKEN_DT":"7/22/2008","CONC":".353","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-07-22"},{"SOURCE_ROW_NUMBER":"865554","CASS_NUM":"50941138","SMP_TAKEN_DT":"7/21/2008","CONC":".787","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-07-21"},{"SOURCE_ROW_NUMBER":"1159244","CASS_NUM":"50941123","SMP_TAKEN_DT":"7/18/2008","CONC":".209","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-07-18"},{"SOURCE_ROW_NUMBER":"335193","CASS_NUM":"50941142","SMP_TAKEN_DT":"7/17/2008","CONC":".337","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-07-17"},{"SOURCE_ROW_NUMBER":"1180875","CASS_NUM":"50941111","SMP_TAKEN_DT":"7/15/2008","CONC":".326","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-07-15"},{"SOURCE_ROW_NUMBER":"117996","CASS_NUM":"50964860","SMP_TAKEN_DT":"6/27/2008","CONC":".17","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-06-27"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":1,"firstDate":"2007-06-27","lastDate":"2007-06-27","metrics":{"linkedIssuances":1},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":29,"firstDate":"2008-06-10","lastDate":"2008-08-26","metrics":{"decisions":29,"ssChanged":29,"recentRows":0,"decisionPenalty":50123,"proposedPenalty":50123},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"123216","CITATION_NO":"6622737","CITATION_ISSUE_DT":"08/26/2008","DOCKET_NO":"WEVA 2009-354","DECISION_DT":"01/04/2011","CFR_STANDARD_CODE":"75.1103-4(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"634.00","DECISION_PENALTY_AMT":"634.00","sourceDate":"2008-08-26"},{"SOURCE_ROW_NUMBER":"10591","CITATION_NO":"6622738","CITATION_ISSUE_DT":"08/26/2008","DOCKET_NO":"WEVA 2009-354","DECISION_DT":"01/04/2011","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1412.00","DECISION_PENALTY_AMT":"1412.00","sourceDate":"2008-08-26"},{"SOURCE_ROW_NUMBER":"66091","CITATION_NO":"6616545","CITATION_ISSUE_DT":"06/19/2008","DOCKET_NO":"WEVA 2008-1852","DECISION_DT":"07/19/2010","CFR_STANDARD_CODE":"75.1106-2(a)(1)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"150.00","DECISION_PENALTY_AMT":"150.00","sourceDate":"2008-06-19"},{"SOURCE_ROW_NUMBER":"11306","CITATION_NO":"6616546","CITATION_ISSUE_DT":"06/19/2008","DOCKET_NO":"WEVA 2008-1852","DECISION_DT":"07/19/2010","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"308.00","DECISION_PENALTY_AMT":"308.00","sourceDate":"2008-06-19"},{"SOURCE_ROW_NUMBER":"350204","CITATION_NO":"6616537","CITATION_ISSUE_DT":"06/16/2008","DOCKET_NO":"WEVA 2008-1852","DECISION_DT":"07/19/2010","CFR_STANDARD_CODE":"75.1002(a)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"190.00","DECISION_PENALTY_AMT":"190.00","sourceDate":"2008-06-16"},{"SOURCE_ROW_NUMBER":"292966","CITATION_NO":"6616539","CITATION_ISSUE_DT":"06/16/2008","DOCKET_NO":"WEVA 2008-1851","DECISION_DT":"08/11/2010","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3493.00","DECISION_PENALTY_AMT":"3493.00","sourceDate":"2008-06-16"},{"SOURCE_ROW_NUMBER":"236920","CITATION_NO":"6616541","CITATION_ISSUE_DT":"06/16/2008","DOCKET_NO":"WEVA 2008-1851","DECISION_DT":"08/11/2010","CFR_STANDARD_CODE":"75.360(b)(3)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"7176.00","DECISION_PENALTY_AMT":"7176.00","sourceDate":"2008-06-16"},{"SOURCE_ROW_NUMBER":"236919","CITATION_NO":"6616538","CITATION_ISSUE_DT":"06/16/2008","DOCKET_NO":"WEVA 2008-1851","DECISION_DT":"08/11/2010","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3784.00","DECISION_PENALTY_AMT":"3784.00","sourceDate":"2008-06-16"},{"SOURCE_ROW_NUMBER":"180112","CITATION_NO":"6616542","CITATION_ISSUE_DT":"06/16/2008","DOCKET_NO":"WEVA 2008-1852","DECISION_DT":"07/19/2010","CFR_STANDARD_CODE":"75.807","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"190.00","DECISION_PENALTY_AMT":"190.00","sourceDate":"2008-06-16"},{"SOURCE_ROW_NUMBER":"179916","CITATION_NO":"6616543","CITATION_ISSUE_DT":"06/16/2008","DOCKET_NO":"WEVA 2008-1851","DECISION_DT":"08/11/2010","CFR_STANDARD_CODE":"75.360(b)(3)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"7176.00","DECISION_PENALTY_AMT":"7176.00","sourceDate":"2008-06-16"},{"SOURCE_ROW_NUMBER":"67864","CITATION_NO":"6616540","CITATION_ISSUE_DT":"06/16/2008","DOCKET_NO":"WEVA 2008-1852","DECISION_DT":"07/19/2010","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"392.00","sourceDate":"2008-06-16"},{"SOURCE_ROW_NUMBER":"11307","CITATION_NO":"6616536","CITATION_ISSUE_DT":"06/13/2008","DOCKET_NO":"WEVA 2008-1852","DECISION_DT":"07/19/2010","CFR_STANDARD_CODE":"75.338(a)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2008-06-13"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":68,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":22,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"2005-05-12","lastDate":"2005-05-12","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":18,"firstDate":"2005-10-03","lastDate":"2009-01-20","metrics":{"inspectors":30,"recentRows":0,"onSiteHours":600.5,"inspectionHours":926.75,"inspectionSamples":140},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"456469","EVENT_NO":"4123117","INSPECTION_BEGIN_DT":"01/20/2009","INSPECTION_END_DT":"01/20/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"1.25","sourceDate":"2009-01-20"},{"SOURCE_ROW_NUMBER":"493007","EVENT_NO":"4118492","INSPECTION_BEGIN_DT":"12/18/2008","INSPECTION_END_DT":"12/19/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2008-12-18"},{"SOURCE_ROW_NUMBER":"602419","EVENT_NO":"4119317","INSPECTION_BEGIN_DT":"09/22/2008","INSPECTION_END_DT":"01/21/2009","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"4.75","sourceDate":"2008-09-22"},{"SOURCE_ROW_NUMBER":"998671","EVENT_NO":"4123102","INSPECTION_BEGIN_DT":"07/30/2008","INSPECTION_END_DT":"09/29/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"173","SUM_TOTAL_ON_SITE_HOURS":"122","sourceDate":"2008-07-30"},{"SOURCE_ROW_NUMBER":"442635","EVENT_NO":"4121415","INSPECTION_BEGIN_DT":"06/23/2008","INSPECTION_END_DT":"06/23/2008","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2008-06-23"},{"SOURCE_ROW_NUMBER":"947899","EVENT_NO":"4117870","INSPECTION_BEGIN_DT":"05/13/2008","INSPECTION_END_DT":"06/20/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"132.75","SUM_TOTAL_ON_SITE_HOURS":"83","sourceDate":"2008-05-13"},{"SOURCE_ROW_NUMBER":"189488","EVENT_NO":"4119307","INSPECTION_BEGIN_DT":"02/04/2008","INSPECTION_END_DT":"03/31/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"54.5","SUM_TOTAL_ON_SITE_HOURS":"38","sourceDate":"2008-02-04"},{"SOURCE_ROW_NUMBER":"487835","EVENT_NO":"4117292","INSPECTION_BEGIN_DT":"10/17/2007","INSPECTION_END_DT":"12/05/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"115.5","SUM_TOTAL_ON_SITE_HOURS":"76.5","sourceDate":"2007-10-17"},{"SOURCE_ROW_NUMBER":"301899","EVENT_NO":"4115141","INSPECTION_BEGIN_DT":"07/10/2007","INSPECTION_END_DT":"07/19/2007","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"48.5","SUM_TOTAL_ON_SITE_HOURS":"33.5","sourceDate":"2007-07-10"},{"SOURCE_ROW_NUMBER":"1119965","EVENT_NO":"4115836","INSPECTION_BEGIN_DT":"05/09/2007","INSPECTION_END_DT":"05/09/2007","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.75","SUM_TOTAL_ON_SITE_HOURS":"1.25","sourceDate":"2007-05-09"},{"SOURCE_ROW_NUMBER":"495462","EVENT_NO":"4114731","INSPECTION_BEGIN_DT":"04/13/2007","INSPECTION_END_DT":"06/07/2007","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"50.25","SUM_TOTAL_ON_SITE_HOURS":"32.25","sourceDate":"2007-04-13"},{"SOURCE_ROW_NUMBER":"155899","EVENT_NO":"4117258","INSPECTION_BEGIN_DT":"02/05/2007","INSPECTION_END_DT":"02/08/2007","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"40.75","SUM_TOTAL_ON_SITE_HOURS":"28.25","sourceDate":"2007-02-05"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":30,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2008-Q4":{"hours":590,"employees":1,"production":0},"2008-Q3":{"hours":2576,"employees":6,"production":4597},"2008-Q2":{"hours":4547,"employees":7,"production":10002},"2008-Q1":{"hours":3467,"employees":8,"production":8792},"2007-Q4":{"hours":4024,"employees":8,"production":10622},"2007-Q3":{"hours":4012,"employees":8,"production":10197},"2007-Q2":{"hours":4198,"employees":8,"production":11953},"2007-Q1":{"hours":4528,"employees":8,"production":9632},"2006-Q4":{"hours":3950,"employees":8,"production":6599},"2006-Q3":{"hours":4147,"employees":8,"production":11982},"2006-Q2":{"hours":4338,"employees":8,"production":12514},"2006-Q1":{"hours":4353,"employees":8,"production":12934}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":5,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2005":{"hours":2114,"employees":7,"production":6026},"2006":{"hours":16788,"employees":8,"production":44029},"2007":{"hours":16762,"employees":8,"production":42404},"2008":{"hours":11180,"employees":8,"production":23391}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":10,"firstDate":"2006-05-01","lastDate":"2008-08-28","metrics":{"recentRows":0,"doseOver100":1,"actDoseTotal":423,"pelDoseTotal":316},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"255554","EVENT_NO":"4123102","SURVEY_DATE":"08/28/2008","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"41","PEL_DOSE_90":"26","SURVEY_TYPE":"I","sourceDate":"2008-08-28"},{"SOURCE_ROW_NUMBER":"255553","EVENT_NO":"4123102","SURVEY_DATE":"08/28/2008","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"07","MANUFACTURER_CD":"066","ACT_DOSE_85":"73","PEL_DOSE_90":"56","SURVEY_TYPE":"I","sourceDate":"2008-08-28"},{"SOURCE_ROW_NUMBER":"255552","EVENT_NO":"4123102","SURVEY_DATE":"08/28/2008","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"043","ACT_DOSE_85":"111","PEL_DOSE_90":"89","SURVEY_TYPE":"I","sourceDate":"2008-08-28"},{"SOURCE_ROW_NUMBER":"255551","EVENT_NO":"4123102","SURVEY_DATE":"08/28/2008","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"08","MANUFACTURER_CD":"067","ACT_DOSE_85":"39","PEL_DOSE_90":"39","SURVEY_TYPE":"I","sourceDate":"2008-08-28"},{"SOURCE_ROW_NUMBER":"255550","EVENT_NO":"4123102","SURVEY_DATE":"08/28/2008","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"08","MANUFACTURER_CD":"067","ACT_DOSE_85":"36","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2008-08-28"},{"SOURCE_ROW_NUMBER":"255549","EVENT_NO":"4106292","SURVEY_DATE":"05/01/2006","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"18","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2006-05-01"},{"SOURCE_ROW_NUMBER":"255548","EVENT_NO":"4106292","SURVEY_DATE":"05/01/2006","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"35","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2006-05-01"},{"SOURCE_ROW_NUMBER":"255547","EVENT_NO":"4106292","SURVEY_DATE":"05/01/2006","OCCUPATION_CD_DESC":"ROOF BOLTER HELPER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"043","ACT_DOSE_85":"20","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2006-05-01"},{"SOURCE_ROW_NUMBER":"255546","EVENT_NO":"4106292","SURVEY_DATE":"05/01/2006","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"043","ACT_DOSE_85":"23","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2006-05-01"},{"SOURCE_ROW_NUMBER":"255545","EVENT_NO":"4106292","SURVEY_DATE":"05/01/2006","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"066","ACT_DOSE_85":"27","PEL_DOSE_90":"18","SURVEY_TYPE":"I","sourceDate":"2006-05-01"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":3,"firstDate":"2006-02-08","lastDate":"2006-04-27","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":4.2,"validSamples":3,"quartzPctTotal":10.3},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"122489","CASSETTE_NO":"57630218","SAMPLE_DT":"04/27/2006","QUARTZ_PCT":"03.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-04-27"},{"SOURCE_ROW_NUMBER":"115038","CASSETTE_NO":"57630057","SAMPLE_DT":"04/11/2006","QUARTZ_PCT":"02.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-04-11"},{"SOURCE_ROW_NUMBER":"152937","CASSETTE_NO":"57552357","SAMPLE_DT":"02/08/2006","QUARTZ_PCT":"04.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-02-08"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":138,"firstDate":"2006-02-06","lastDate":"2008-09-22","metrics":{"ss":46,"amountDue":90142,"contested":29,"amountPaid":14160.88,"recentRows":0,"section104d":12,"unterminated":1,"proposedPenalty":90142},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2887882","VIOLATION_NO":"6623876","VIOLATION_ISSUE_DT":"09/22/2008","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"01/21/2009","CONTESTED_IND":"N","sourceDate":"2008-09-22"},{"SOURCE_ROW_NUMBER":"2887866","VIOLATION_NO":"6622740","VIOLATION_ISSUE_DT":"08/27/2008","SIG_SUB":"Y","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/28/2008","PROPOSED_PENALTY":"150","AMOUNT_DUE":"150","AMOUNT_PAID":"150","CONTESTED_IND":"N","sourceDate":"2008-08-27"},{"SOURCE_ROW_NUMBER":"2887865","VIOLATION_NO":"6622739","VIOLATION_ISSUE_DT":"08/27/2008","SIG_SUB":"N","PART_SECTION":"77.1710(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/28/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-08-27"},{"SOURCE_ROW_NUMBER":"2887867","VIOLATION_NO":"6622741","VIOLATION_ISSUE_DT":"08/26/2008","SIG_SUB":"N","PART_SECTION":"77.1606(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/26/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2008-08-26"},{"SOURCE_ROW_NUMBER":"2887864","VIOLATION_NO":"6622738","VIOLATION_ISSUE_DT":"08/26/2008","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/27/2008","PROPOSED_PENALTY":"1412","AMOUNT_DUE":"1412","AMOUNT_PAID":"0","CONTESTED_IND":"Y","DOCKET_NO":"WEVA 2009-354","sourceDate":"2008-08-26"},{"SOURCE_ROW_NUMBER":"2887863","VIOLATION_NO":"6622737","VIOLATION_ISSUE_DT":"08/26/2008","SIG_SUB":"Y","PART_SECTION":"75.1103-4(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/28/2008","PROPOSED_PENALTY":"634","AMOUNT_DUE":"634","AMOUNT_PAID":"0","CONTESTED_IND":"Y","DOCKET_NO":"WEVA 2009-354","sourceDate":"2008-08-26"},{"SOURCE_ROW_NUMBER":"2887862","VIOLATION_NO":"6622736","VIOLATION_ISSUE_DT":"08/26/2008","SIG_SUB":"N","PART_SECTION":"77.1606(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/26/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-08-26"},{"SOURCE_ROW_NUMBER":"2887861","VIOLATION_NO":"6622735","VIOLATION_ISSUE_DT":"08/26/2008","SIG_SUB":"N","PART_SECTION":"77.1606(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/26/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-08-26"},{"SOURCE_ROW_NUMBER":"2887881","VIOLATION_NO":"7266964","VIOLATION_ISSUE_DT":"08/13/2008","SIG_SUB":"Y","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"4","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/13/2008","PROPOSED_PENALTY":"499","AMOUNT_DUE":"499","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2008-08-13"},{"SOURCE_ROW_NUMBER":"2887880","VIOLATION_NO":"7266963","VIOLATION_ISSUE_DT":"08/13/2008","SIG_SUB":"Y","PART_SECTION":"75.515","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/26/2008","PROPOSED_PENALTY":"362","AMOUNT_DUE":"362","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2008-08-13"},{"SOURCE_ROW_NUMBER":"2887879","VIOLATION_NO":"7266962","VIOLATION_ISSUE_DT":"08/13/2008","SIG_SUB":"Y","PART_SECTION":"75.1722(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"3","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/26/2008","PROPOSED_PENALTY":"425","AMOUNT_DUE":"425","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2008-08-13"},{"SOURCE_ROW_NUMBER":"2887878","VIOLATION_NO":"7266961","VIOLATION_ISSUE_DT":"08/13/2008","SIG_SUB":"Y","PART_SECTION":"75.1101-7(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"4","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/26/2008","PROPOSED_PENALTY":"499","AMOUNT_DUE":"499","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2008-08-13"}]}],"safety":{"href":"/api/v1/mines/4609104/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609104/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":1},{"chapter":"I","heading":"Protective clothing; requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-R/section-77.1710","part":"77","subchapter":"O","subpart":"R","id":"77.1710","citation":"30 CFR 77.1710","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1103-4","heading":"Automatic fire sensor and warning device systems; installation; minimum requirements.","id":"75.1103-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Effective December 31, 2009, automatic fire sensor and warning device systems that use carbon monoxide sensors shall provide identification of fire along all belt conveyors.\n\n(1) Carbon monoxide sensors shall be installed at the following locations:\n\n(i) Not more than 100 feet downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up. If the belt drive, tailpiece, and/or take-up for a single transfer point are installed together in the same air course, and the distance between the units is less than 100 feet, they may be monitored with one sensor downwind of the last component. If the distance between the units exceeds 100 feet, additional sensors are required downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up;\n\n(ii) Not more than 100 feet downwind of each section loading point;\n\n(iii) Along the belt entry so that the spacing between sensors does not exceed 1,000 feet. Where air velocities are less than 50 feet per minute, spacing must not exceed 350 feet; and\n\n(iv) The mine operator shall indicate the locations of all carbon monoxide sensors on the mine maps required by §§ 75.1200 and 75.1505 of this part.\n\n(2) Where used, sensors responding to radiation, smoke, gases, or other indications of fire, shall be spaced at regular intervals to provide protection equivalent to carbon monoxide sensors, and installed within the time specified in paragraph (a)(3) of this section.\n\n(3) When the distance from the tailpiece at loading points to the first outby sensor reaches the spacing requirements in § 75.1103-4(a)(1)(iii), an additional sensor shall be installed and put in operation within 24 production shift hours. When sensors of the kind described in paragraph (a)(2) of this section are used, they shall be installed and put in operation within 24 production shift hours after the equivalent distance which has been established for the sensor from the tailpiece at loading points to the first outby sensor is first reached.\n\n(b) Automatic fire sensor and warning device systems shall be installed so as to minimize the possibility of damage from roof falls and the moving belt and its load. Sensors must be installed near the center in the upper third of the entry, in a manner that does not expose personnel working on the system to unsafe conditions. Sensors must not be located in abnormally high areas or in other locations where air flow patterns do not permit products of combustion to be carried to the sensors.\n\n(c) Infrared, ultraviolet, and other sensors whose effectiveness is impaired by contamination shall be protected from dust, dirt, and moisture.\n\n(d) The voltage of automatic fire sensor and warning device systems shall not exceed 120 volts.\n\n(e) Except when power must be cut off in the mine under the provisions of § 75.313, automatic fire sensor and warning device systems shall be capable of giving warning of fire for a minimum of 4 hours after the source of power to the belt is removed unless the belt haulageway is examined for hot rollers and fire as provided in paragraph (e) (1) or (2) of this section.\n\n(1) When an unplanned removal of power from the belt occurs an examination for hot rollers and fire in the operating belts of a conveyor system shall be completed within 2 hours after the belt has stopped.\n\n(2) When a preplanned removal of power from the belt occurs an examination for hot rollers and fire on the operating belts of a conveyor system may commence not more than 30 minutes before the belts are stopped and shall be completed within 2 hours after the examination is commenced, or the examination shall be commenced when the belts are stopped and completed within 2 hours after the belts are stopped.\n\n[37 FR 16545, Aug. 16, 1972, as amended at 57 FR 20928, May 15, 1992; 73 FR 80614, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.515","heading":"Cable fittings; suitability.","id":"75.515","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.515","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nCables shall enter metal frames of motors, splice boxes, and electric compartments only through proper fittings. When insulated wires other than cables pass through metal frames, the holes shall be substantially bushed with insulated bushings.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1722","heading":"Mechanical equipment guards.","id":"75.1722","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1722","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1101-7","heading":"Installation of water sprinkler systems; requirements.","id":"75.1101-7","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1101-7","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) The fire-control components of each water sprinkler system shall be installed, as far as practicable in accordance with the recommendations set forth in National Fire Protection Association 1968-69 edition, Code No. 13, “Installation of Sprinkler Systems” and such systems' components shall be of a type approved by the Underwriters' Laboratories, Inc., Factory Mutual Research Corp.\n\n(b) Each sprinkler system shall provide protection for the motor drive belt takeup, electrical controls, gear reducing unit, and the 50 feet of fire-resistant belt, or 150 feet of nonfire-resistant belt adjacent to the belt drive.\n\n(c) The components of each water sprinkler system shall be located so as to minimize the possibility of damage by roof fall or by the moving belt and its load.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609104","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}