{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"4609082","name":"Coalburg No 1 Mine","status":"Abandoned and Sealed","status_date":"2012-10-10","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Boone","nearest_town":"Prenter","operator_id":"0056457","operator_name":"Jarrell's Branch Coal Company","controller_id":"C15833","controller_name":"Peabody Energy Corporation","district":"C04","office":"Madison WV Field Office","employees":0,"latitude":37.996388,"longitude":-81.623055},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":4528},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609082","name":"Coalburg No 1 Mine"},"operator":{"type":"operator","id":"0056457","name":"Jarrell's Branch Coal Company"},"controller":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C14767","name":"James Roy  Lucas"},"object":{"type":"mine","id":"4609082","name":"Coalburg No 1 Mine"},"validFrom":"1992-12-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609082|C14767|1992-12-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15194","name":"Douglas M  Epling"},"object":{"type":"mine","id":"4609082","name":"Coalburg No 1 Mine"},"validFrom":"1994-12-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609082|C15194|1994-12-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0056457","name":"Jarrell's Branch Coal Company"},"object":{"type":"mine","id":"4609082","name":"Coalburg No 1 Mine"},"validFrom":"2004-12-09","validTo":"2005-07-21","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609082|0056457|2004-12-09|2005-07-21"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"mine","id":"4609082","name":"Coalburg No 1 Mine"},"validFrom":"2004-12-09","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609082|C15833|2004-12-09|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"operator","id":"0056457","name":"Jarrell's Branch Coal Company"},"validFrom":"2004-12-09","validTo":"2005-07-21","current":false,"derived":true,"evidenceMineId":"4609082","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609082|0056457|2004-12-09|C15833|2004-12-09|97025"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22186","name":"Point Mining Inc"},"object":{"type":"mine","id":"4609082","name":"Coalburg No 1 Mine"},"validFrom":"2005-07-22","validTo":"2007-03-04","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609082|P22186|2005-07-22|2007-03-04"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14767","name":"James Roy  Lucas"},"object":{"type":"operator","id":"P22186","name":"Point Mining Inc"},"validFrom":"2005-07-22","validTo":"2007-03-04","current":false,"derived":true,"evidenceMineId":"4609082","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609082|P22186|2005-07-22|C14767|1992-12-01|93866"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23018","name":"Mountain Edge Mining, Inc."},"object":{"type":"mine","id":"4609082","name":"Coalburg No 1 Mine"},"validFrom":"2007-03-05","validTo":"2011-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609082|P23018|2007-03-05|2011-05-31"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15194","name":"Douglas M  Epling"},"object":{"type":"operator","id":"P23018","name":"Mountain Edge Mining, Inc."},"validFrom":"2007-03-05","validTo":"2011-05-31","current":false,"derived":true,"evidenceMineId":"4609082","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609082|P23018|2007-03-05|C15194|1994-12-01|95022"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0118289","name":"Signature Mining Services LLC"},"object":{"type":"mine","id":"4609082","name":"Coalburg No 1 Mine"},"validFrom":"2011-06-01","validTo":"2012-01-19","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609082|0118289|2011-06-01|2012-01-19"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0055749","name":"Randel L  Richmond"},"object":{"type":"mine","id":"4609082","name":"Coalburg No 1 Mine"},"validFrom":"2011-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609082|0055749|2011-06-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0055749","name":"Randel L  Richmond"},"object":{"type":"operator","id":"0118289","name":"Signature Mining Services LLC"},"validFrom":"2011-06-01","validTo":"2012-01-19","current":false,"derived":true,"evidenceMineId":"4609082","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609082|0118289|2011-06-01|0055749|2011-06-01|7232"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0056457","name":"Jarrell's Branch Coal Company"},"object":{"type":"mine","id":"4609082","name":"Coalburg No 1 Mine"},"validFrom":"2012-01-20","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609082|0056457|2012-01-20|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"operator","id":"0056457","name":"Jarrell's Branch Coal Company"},"validFrom":"2012-01-20","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609082","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609082|0056457|2012-01-20|C15833|2004-12-09|97026"}}],"coverage":{"historyRecords":5,"edgeCount":14,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":60,"firstDate":"2005-10-26","lastDate":"2011-09-06","metrics":{"daysLost":1695,"injuries":42,"fatalities":0,"recentRows":0,"restrictedDays":48,"contractorRecords":8},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"16835","DOCUMENT_NO":"220112550049","ACCIDENT_DT":"09/06/2011","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Fall extended above anchorage point, reported to be 8 feet high and the immediate roof appeared to be laminated shale with slickensides. Fall blocked roadway and occurred at No.17 Break of 1Rt.-Southwest Mains, one break inby No.6 Belthead and one break outby spad 1646. Dimensions: 20 feet wide and 23 feel long.","sourceDate":"2011-09-06"},{"SOURCE_ROW_NUMBER":"124114","DOCUMENT_NO":"220112520064","ACCIDENT_DT":"08/31/2011","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Fall extended above anchorage point, reported to be up to 10 feet high and the immediate roof appeared to be laminated shale with slickensides. Fall blocked roadway and beltline. Fall occurred at No.2 Break of No.5 Belt between spads 11655 and 1507, No. 1 Entry and No.2 Entry. Dimensions: 17 to 18 feet wide and 60 to 70 feet long.","sourceDate":"2011-08-31"},{"SOURCE_ROW_NUMBER":"29792","DOCUMENT_NO":"220112520063","ACCIDENT_DT":"08/31/2011","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Fall extended above anchorage point, reported to be 6 to 8 feet high and the immediate roof appeared to be laminated shale with slickensides. Fall occurred at No.17 Break of No.4 Belt between spad 1400 and 1409, between No. 2 Entry and No.3 Entry. Dimensions: 17 to 18 feet wide and 20 to 30 feet long.","sourceDate":"2011-08-31"},{"SOURCE_ROW_NUMBER":"124113","DOCUMENT_NO":"220112430051","ACCIDENT_DT":"08/23/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"101","NARRATIVE":"A small piece of rock fell between roof bolts, hitting the victim on the upper left shoulder and knocking him to the ground. The victim received bruising to his left shoulder, upper back, and laceration to his mouth. The laceration caused from being knocked to the ground, not the rock itself. (His teeth cut his mouth)","sourceDate":"2011-08-23"},{"SOURCE_ROW_NUMBER":"266367","DOCUMENT_NO":"220112310046","ACCIDENT_DT":"08/09/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Struck by rolling or sliding object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"27","NARRATIVE":"Worker was walking away from the continuous miner to help repair a burst waterline. A rib approx. 4'6\"x 32\"x 9\" rolled off striking the victim in the back and knocking him down. Injuries include 2 fractures to pelvis, fractured tailbone and right ankle.","sourceDate":"2011-08-09"},{"SOURCE_ROW_NUMBER":"128469","DOCUMENT_NO":"220112310045","ACCIDENT_DT":"08/08/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Struck by rolling or sliding object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"28","NARRATIVE":"Worker was moving MRS unit out of area where mining was completed. He stopped the MRS & walked toward it. When he was appr 8' from front of MRS & about 4' away from ribline a piece of top part of rib broke loose & fell about 6' striking victim on left side of upper torso. He finished working shift. Accident occurred in xcut. Mine ht was about 11 1/2'. He declined med treatment.","sourceDate":"2011-08-08"},{"SOURCE_ROW_NUMBER":"132827","DOCUMENT_NO":"220111670038","ACCIDENT_DT":"06/09/2011","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Roof fall in intersection on the #1 belt conveyor. Slickensided roof conditions in the area. Transition zone between sandstone and shale roof.","sourceDate":"2011-06-09"},{"SOURCE_ROW_NUMBER":"46972","DOCUMENT_NO":"220111400041","ACCIDENT_DT":"05/11/2011","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Slicken sided formation with laminated shale fell at or near anchorage zone 16'-17' L. X 16'-19' W. X 6'-6.5' Thick.","sourceDate":"2011-05-11"},{"SOURCE_ROW_NUMBER":"214795","DOCUMENT_NO":"220110200005","ACCIDENT_DT":"01/18/2011","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"64","NARRATIVE":"Employee was rolling out tensar on the corner of intersection with two other employees.  A section of the rib, 62\" long, 12\" thick and 2\" wide rolled off striking employee on his left lower leg, causing a compound fracture.","sourceDate":"2011-01-18"},{"SOURCE_ROW_NUMBER":"89950","DOCUMENT_NO":"220110180010","ACCIDENT_DT":"01/06/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"5","NARRATIVE":"While employee was checking supplies on bolter, rock about 4' wide, 3' long, 8\" to 10\" thick fell out between bolts hitting the left side of his body; including his head, face, neck, shoulder, arm and hand.","sourceDate":"2011-01-06"},{"SOURCE_ROW_NUMBER":"145851","DOCUMENT_NO":"220110100023","ACCIDENT_DT":"12/22/2010","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"5","NARRATIVE":"EE was walking in drift mouth when he slipped and twisted his ankle. EE was released to go back to work but chose not to.","sourceDate":"2010-12-22"},{"SOURCE_ROW_NUMBER":"236327","DOCUMENT_NO":"220103400056","ACCIDENT_DT":"11/19/2010","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"39","NARRATIVE":"EE stepped off of mantrip and twisted his right ankle.","sourceDate":"2010-11-19"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2012-10-10","lastDate":"2012-10-10","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":980,"firstDate":"2005-06-01","lastDate":"2011-11-28","metrics":{"ss":409,"delinquent":980,"recentRows":0,"paidPenalty":630223,"proposedPenalty":1094338,"currentAssessment":642004},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1776626","VIOLATION_NO":"4637302","ISSUE_DT":"11/28/2011","CFR_STANDARD_CD":"77.208(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-11-28"},{"SOURCE_ROW_NUMBER":"1776625","VIOLATION_NO":"4637301","ISSUE_DT":"11/28/2011","CFR_STANDARD_CD":"75.523-2(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"138.00","CURRENT_ASSESSMENT_AMT":"138.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-11-28"},{"SOURCE_ROW_NUMBER":"1776628","VIOLATION_NO":"8125000","ISSUE_DT":"11/18/2011","CFR_STANDARD_CD":"75.1107-16(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-11-18"},{"SOURCE_ROW_NUMBER":"1776627","VIOLATION_NO":"8124998","ISSUE_DT":"10/27/2011","CFR_STANDARD_CD":"75.364(a)(2)(i)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-10-27"},{"SOURCE_ROW_NUMBER":"848638","VIOLATION_NO":"7257540","ISSUE_DT":"09/15/2011","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"142100.00","CURRENT_ASSESSMENT_AMT":"10000.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-09-15"},{"SOURCE_ROW_NUMBER":"1803826","VIOLATION_NO":"8139506","ISSUE_DT":"08/23/2011","CFR_STANDARD_CD":"75.1101-6","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2901.00","CURRENT_ASSESSMENT_AMT":"2901.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-08-23"},{"SOURCE_ROW_NUMBER":"1803825","VIOLATION_NO":"8139505","ISSUE_DT":"08/23/2011","CFR_STANDARD_CD":"75.362(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"224.00","CURRENT_ASSESSMENT_AMT":"224.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-08-23"},{"SOURCE_ROW_NUMBER":"1803824","VIOLATION_NO":"8139504","ISSUE_DT":"08/23/2011","CFR_STANDARD_CD":"75.1722(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"334.00","CURRENT_ASSESSMENT_AMT":"334.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-08-23"},{"SOURCE_ROW_NUMBER":"1803823","VIOLATION_NO":"8139503","ISSUE_DT":"08/22/2011","CFR_STANDARD_CD":"75.523-2(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"334.00","CURRENT_ASSESSMENT_AMT":"334.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-08-22"},{"SOURCE_ROW_NUMBER":"1803822","VIOLATION_NO":"8139500","ISSUE_DT":"08/18/2011","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"745.00","CURRENT_ASSESSMENT_AMT":"745.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-08-18"},{"SOURCE_ROW_NUMBER":"1803821","VIOLATION_NO":"8139499","ISSUE_DT":"08/18/2011","CFR_STANDARD_CD":"75.1106-3(a)(2)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1111.00","CURRENT_ASSESSMENT_AMT":"1111.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-08-18"},{"SOURCE_ROW_NUMBER":"1803820","VIOLATION_NO":"8139498","ISSUE_DT":"08/18/2011","CFR_STANDARD_CD":"75.1722(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-08-18"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":444,"firstDate":"2010-04-12","lastDate":"2014-03-31","metrics":{"appeals":0,"decisions":444,"recentRows":0,"decisionPenalty":470497,"originalPenalty":939505},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"116355","VIOLATION_NO":"8105681","DOCKET_NO":"WEVA 2013-515","DECISION_DT":"03/31/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"6300.00","DECISION_PENALTY_AMT":"3000.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2014-03-31"},{"SOURCE_ROW_NUMBER":"347429","VIOLATION_NO":"8139504","DOCKET_NO":"WEVA 2012-185","DECISION_DT":"07/11/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"334.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2013-07-11"},{"SOURCE_ROW_NUMBER":"347428","VIOLATION_NO":"8139498","DOCKET_NO":"WEVA 2012-185","DECISION_DT":"07/11/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2013-07-11"},{"SOURCE_ROW_NUMBER":"347427","VIOLATION_NO":"8139491","DOCKET_NO":"WEVA 2012-185","DECISION_DT":"07/11/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"499.00","DECISION_PENALTY_AMT":"300.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2013-07-11"},{"SOURCE_ROW_NUMBER":"346801","VIOLATION_NO":"8139497","DOCKET_NO":"WEVA 2012-185","DECISION_DT":"07/11/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"334.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2013-07-11"},{"SOURCE_ROW_NUMBER":"346603","VIOLATION_NO":"8139493","DOCKET_NO":"WEVA 2012-185","DECISION_DT":"07/11/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"745.00","DECISION_PENALTY_AMT":"500.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2013-07-11"},{"SOURCE_ROW_NUMBER":"105755","VIOLATION_NO":"8139489","DOCKET_NO":"WEVA 2012-185","DECISION_DT":"07/11/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"499.00","DECISION_PENALTY_AMT":"300.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2013-07-11"},{"SOURCE_ROW_NUMBER":"105386","VIOLATION_NO":"8139500","DOCKET_NO":"WEVA 2012-185","DECISION_DT":"07/11/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"745.00","DECISION_PENALTY_AMT":"745.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2013-07-11"},{"SOURCE_ROW_NUMBER":"105385","VIOLATION_NO":"8139495","DOCKET_NO":"WEVA 2012-185","DECISION_DT":"07/11/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2473.00","DECISION_PENALTY_AMT":"1302.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2013-07-11"},{"SOURCE_ROW_NUMBER":"105323","VIOLATION_NO":"8139490","DOCKET_NO":"WEVA 2012-185","DECISION_DT":"07/11/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"499.00","DECISION_PENALTY_AMT":"300.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2013-07-11"},{"SOURCE_ROW_NUMBER":"105193","VIOLATION_NO":"8139488","DOCKET_NO":"WEVA 2012-185","DECISION_DT":"07/11/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"499.00","DECISION_PENALTY_AMT":"300.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2013-07-11"},{"SOURCE_ROW_NUMBER":"105042","VIOLATION_NO":"9969236","DOCKET_NO":"WEVA 2012-185","DECISION_DT":"07/11/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"585.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2013-07-11"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":640,"firstDate":"2005-11-15","lastDate":"2099-05-06","metrics":{"recentRows":1,"cpdmSamples":0,"voidSamples":136,"validSamples":504,"maxConcentration":18.897,"concentrationTotal":336.762},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"931415","CASS_NUM":"51028193","SMP_TAKEN_DT":"5/6/2099","CONC":".505","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"PREDATED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2099-05-06"},{"SOURCE_ROW_NUMBER":"1634690","CASS_NUM":"57908359","SMP_TAKEN_DT":"8/25/2011","CONC":".155","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-08-25"},{"SOURCE_ROW_NUMBER":"1294511","CASS_NUM":"57908300","SMP_TAKEN_DT":"8/25/2011","CONC":".148","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-08-25"},{"SOURCE_ROW_NUMBER":"1161437","CASS_NUM":"57908398","SMP_TAKEN_DT":"8/25/2011","CONC":".695","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ELECTRICIAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-08-25"},{"SOURCE_ROW_NUMBER":"1113077","CASS_NUM":"57908349","SMP_TAKEN_DT":"8/25/2011","CONC":".184","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-08-25"},{"SOURCE_ROW_NUMBER":"682279","CASS_NUM":"57908337","SMP_TAKEN_DT":"8/25/2011","CONC":"1.247","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-08-25"},{"SOURCE_ROW_NUMBER":"589529","CASS_NUM":"57908323","SMP_TAKEN_DT":"8/25/2011","CONC":"1.134","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-08-25"},{"SOURCE_ROW_NUMBER":"401799","CASS_NUM":"57908345","SMP_TAKEN_DT":"8/25/2011","CONC":".448","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-08-25"},{"SOURCE_ROW_NUMBER":"278415","CASS_NUM":"57908310","SMP_TAKEN_DT":"8/25/2011","CONC":".111","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-08-25"},{"SOURCE_ROW_NUMBER":"212816","CASS_NUM":"57908312","SMP_TAKEN_DT":"8/25/2011","CONC":".747","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-08-25"},{"SOURCE_ROW_NUMBER":"202218","CASS_NUM":"57908298","SMP_TAKEN_DT":"8/25/2011","CONC":".561","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-08-25"},{"SOURCE_ROW_NUMBER":"149548","CASS_NUM":"57908347","SMP_TAKEN_DT":"8/25/2011","CONC":".779","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-08-25"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":9,"firstDate":"2007-10-08","lastDate":"2012-01-12","metrics":{"linkedIssuances":9},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":444,"firstDate":"2008-02-01","lastDate":"2011-09-15","metrics":{"decisions":444,"ssChanged":27,"recentRows":0,"decisionPenalty":470497,"proposedPenalty":939505},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"137731","CITATION_NO":"7257540","CITATION_ISSUE_DT":"09/15/2011","DOCKET_NO":"WEVA 2012-1555","DECISION_DT":"04/17/2013","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"142100.00","DECISION_PENALTY_AMT":"10000.00","sourceDate":"2011-09-15"},{"SOURCE_ROW_NUMBER":"58158","CITATION_NO":"9969236","CITATION_ISSUE_DT":"08/24/2011","DOCKET_NO":"WEVA 2012-185","DECISION_DT":"07/11/2013","CFR_STANDARD_CODE":"70.101","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"585.00","sourceDate":"2011-08-24"},{"SOURCE_ROW_NUMBER":"310663","CITATION_NO":"8139504","CITATION_ISSUE_DT":"08/23/2011","DOCKET_NO":"WEVA 2012-185","DECISION_DT":"07/11/2013","CFR_STANDARD_CODE":"75.1722(c)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"334.00","sourceDate":"2011-08-23"},{"SOURCE_ROW_NUMBER":"309154","CITATION_NO":"8139498","CITATION_ISSUE_DT":"08/18/2011","DOCKET_NO":"WEVA 2012-185","DECISION_DT":"07/11/2013","CFR_STANDARD_CODE":"75.1722(c)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2011-08-18"},{"SOURCE_ROW_NUMBER":"307792","CITATION_NO":"8139500","CITATION_ISSUE_DT":"08/18/2011","DOCKET_NO":"WEVA 2012-185","DECISION_DT":"07/11/2013","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"745.00","DECISION_PENALTY_AMT":"745.00","sourceDate":"2011-08-18"},{"SOURCE_ROW_NUMBER":"249812","CITATION_NO":"8139497","CITATION_ISSUE_DT":"08/18/2011","DOCKET_NO":"WEVA 2012-185","DECISION_DT":"07/11/2013","CFR_STANDARD_CODE":"75.1722(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"334.00","sourceDate":"2011-08-18"},{"SOURCE_ROW_NUMBER":"309155","CITATION_NO":"8139495","CITATION_ISSUE_DT":"08/16/2011","DOCKET_NO":"WEVA 2012-185","DECISION_DT":"07/11/2013","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2473.00","DECISION_PENALTY_AMT":"1302.00","sourceDate":"2011-08-16"},{"SOURCE_ROW_NUMBER":"306488","CITATION_NO":"8139493","CITATION_ISSUE_DT":"08/10/2011","DOCKET_NO":"WEVA 2012-185","DECISION_DT":"07/11/2013","CFR_STANDARD_CODE":"75.601","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"745.00","DECISION_PENALTY_AMT":"500.00","sourceDate":"2011-08-10"},{"SOURCE_ROW_NUMBER":"422781","CITATION_NO":"8139489","CITATION_ISSUE_DT":"08/08/2011","DOCKET_NO":"WEVA 2012-185","DECISION_DT":"07/11/2013","CFR_STANDARD_CODE":"75.380(d)(7)(vii)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"499.00","DECISION_PENALTY_AMT":"300.00","sourceDate":"2011-08-08"},{"SOURCE_ROW_NUMBER":"309605","CITATION_NO":"8139492","CITATION_ISSUE_DT":"08/08/2011","DOCKET_NO":"WEVA 2012-1128","DECISION_DT":"02/27/2013","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":"207.00","sourceDate":"2011-08-08"},{"SOURCE_ROW_NUMBER":"196317","CITATION_NO":"8139488","CITATION_ISSUE_DT":"08/08/2011","DOCKET_NO":"WEVA 2012-185","DECISION_DT":"07/11/2013","CFR_STANDARD_CODE":"75.1600-3(a)(1)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"499.00","DECISION_PENALTY_AMT":"300.00","sourceDate":"2011-08-08"},{"SOURCE_ROW_NUMBER":"83880","CITATION_NO":"8139490","CITATION_ISSUE_DT":"08/08/2011","DOCKET_NO":"WEVA 2012-185","DECISION_DT":"07/11/2013","CFR_STANDARD_CODE":"75.380(d)(7)(vii)(B)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"499.00","DECISION_PENALTY_AMT":"300.00","sourceDate":"2011-08-08"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":601,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":8,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":151,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":8,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":5,"firstDate":"2004-12-09","lastDate":"2012-01-20","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":4},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":88,"firstDate":"2005-01-07","lastDate":"2013-08-20","metrics":{"inspectors":190,"recentRows":0,"onSiteHours":4061.75,"inspectionHours":6476.25,"inspectionSamples":536},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"781939","EVENT_NO":"6299011","INSPECTION_BEGIN_DT":"08/20/2013","INSPECTION_END_DT":"08/20/2013","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2013-08-20"},{"SOURCE_ROW_NUMBER":"1078666","EVENT_NO":"6295075","INSPECTION_BEGIN_DT":"10/10/2012","INSPECTION_END_DT":"10/10/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2012-10-10"},{"SOURCE_ROW_NUMBER":"920526","EVENT_NO":"6296082","INSPECTION_BEGIN_DT":"07/23/2012","INSPECTION_END_DT":"07/24/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2012-07-23"},{"SOURCE_ROW_NUMBER":"692297","EVENT_NO":"6292775","INSPECTION_BEGIN_DT":"06/11/2012","INSPECTION_END_DT":"06/13/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"27.5","SUM_TOTAL_ON_SITE_HOURS":"10.5","sourceDate":"2012-06-11"},{"SOURCE_ROW_NUMBER":"792438","EVENT_NO":"6285349","INSPECTION_BEGIN_DT":"01/23/2012","INSPECTION_END_DT":"02/13/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2012-01-23"},{"SOURCE_ROW_NUMBER":"974747","EVENT_NO":"6285346","INSPECTION_BEGIN_DT":"12/29/2011","INSPECTION_END_DT":"12/29/2011","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2011-12-29"},{"SOURCE_ROW_NUMBER":"900792","EVENT_NO":"6290189","INSPECTION_BEGIN_DT":"10/26/2011","INSPECTION_END_DT":"10/26/2011","ACTIVITY_CODE":"E22","ACTIVITY":"Health Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2011-10-26"},{"SOURCE_ROW_NUMBER":"566472","EVENT_NO":"6285335","INSPECTION_BEGIN_DT":"10/05/2011","INSPECTION_END_DT":"12/07/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"104","SUM_TOTAL_ON_SITE_HOURS":"67.5","sourceDate":"2011-10-05"},{"SOURCE_ROW_NUMBER":"3733","EVENT_NO":"4119589","INSPECTION_BEGIN_DT":"09/07/2011","INSPECTION_END_DT":"09/22/2011","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2011-09-07"},{"SOURCE_ROW_NUMBER":"260292","EVENT_NO":"4119588","INSPECTION_BEGIN_DT":"08/29/2011","INSPECTION_END_DT":"01/19/2012","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"101.5","SUM_TOTAL_ON_SITE_HOURS":"47.75","sourceDate":"2011-08-29"},{"SOURCE_ROW_NUMBER":"348971","EVENT_NO":"6290182","INSPECTION_BEGIN_DT":"07/11/2011","INSPECTION_END_DT":"09/21/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"10","SUM_TOTAL_INSP_HOURS":"460.75","SUM_TOTAL_ON_SITE_HOURS":"277","sourceDate":"2011-07-11"},{"SOURCE_ROW_NUMBER":"883863","EVENT_NO":"6288186","INSPECTION_BEGIN_DT":"06/29/2011","INSPECTION_END_DT":"07/07/2011","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"32.25","SUM_TOTAL_ON_SITE_HOURS":"21.5","sourceDate":"2011-06-29"}]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":22,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2005":{"hours":16986,"employees":24,"production":56781},"2006":{"hours":87565,"employees":51,"production":294568},"2007":{"hours":59826,"employees":30,"production":351654},"2008":{"hours":128794,"employees":55,"production":502819},"2009":{"hours":191075,"employees":74,"production":647239},"2010":{"hours":184876,"employees":79,"production":480622},"2011":{"hours":142712,"employees":64,"production":331623},"2012":{"hours":354,"employees":3,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":63,"firstDate":"2008-01-24","lastDate":"2011-08-10","metrics":{"recentRows":0,"doseOver100":5,"actDoseTotal":4156,"pelDoseTotal":3632},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"254249","EVENT_NO":"6290182","SURVEY_DATE":"08/10/2011","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"79","PEL_DOSE_90":"78","SURVEY_TYPE":"I","sourceDate":"2011-08-10"},{"SOURCE_ROW_NUMBER":"254248","EVENT_NO":"6290182","SURVEY_DATE":"08/10/2011","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"119","ACT_DOSE_85":"81","PEL_DOSE_90":"80","SURVEY_TYPE":"I","sourceDate":"2011-08-10"},{"SOURCE_ROW_NUMBER":"254247","EVENT_NO":"6290182","SURVEY_DATE":"08/10/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"81","PEL_DOSE_90":"80","SURVEY_TYPE":"I","sourceDate":"2011-08-10"},{"SOURCE_ROW_NUMBER":"254246","EVENT_NO":"6290182","SURVEY_DATE":"08/10/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"84","PEL_DOSE_90":"83","SURVEY_TYPE":"I","sourceDate":"2011-08-10"},{"SOURCE_ROW_NUMBER":"254245","EVENT_NO":"6290182","SURVEY_DATE":"08/10/2011","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"85","PEL_DOSE_90":"84","SURVEY_TYPE":"I","sourceDate":"2011-08-10"},{"SOURCE_ROW_NUMBER":"254244","EVENT_NO":"6290182","SURVEY_DATE":"08/02/2011","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"86","PEL_DOSE_90":"85","SURVEY_TYPE":"I","sourceDate":"2011-08-02"},{"SOURCE_ROW_NUMBER":"254243","EVENT_NO":"6290182","SURVEY_DATE":"08/02/2011","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"82","PEL_DOSE_90":"80","SURVEY_TYPE":"I","sourceDate":"2011-08-02"},{"SOURCE_ROW_NUMBER":"254242","EVENT_NO":"6290182","SURVEY_DATE":"08/02/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"89","PEL_DOSE_90":"88","SURVEY_TYPE":"I","sourceDate":"2011-08-02"},{"SOURCE_ROW_NUMBER":"254241","EVENT_NO":"6290182","SURVEY_DATE":"08/02/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"86","PEL_DOSE_90":"86","SURVEY_TYPE":"I","sourceDate":"2011-08-02"},{"SOURCE_ROW_NUMBER":"254240","EVENT_NO":"6290182","SURVEY_DATE":"08/02/2011","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"89","PEL_DOSE_90":"88","SURVEY_TYPE":"I","sourceDate":"2011-08-02"},{"SOURCE_ROW_NUMBER":"254239","EVENT_NO":"6288726","SURVEY_DATE":"01/10/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"56","PEL_DOSE_90":"33","SURVEY_TYPE":"I","sourceDate":"2011-01-10"},{"SOURCE_ROW_NUMBER":"254238","EVENT_NO":"6288726","SURVEY_DATE":"01/10/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"51","PEL_DOSE_90":"29","SURVEY_TYPE":"I","sourceDate":"2011-01-10"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":14,"firstDate":"2005-11-15","lastDate":"2011-08-25","metrics":{"recentRows":0,"voidSamples":1,"maxQuartzPct":9.7,"validSamples":13,"quartzPctTotal":69.6},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"13723","CASSETTE_NO":"57908337","SAMPLE_DT":"08/25/2011","QUARTZ_PCT":"05.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-08-25"},{"SOURCE_ROW_NUMBER":"48485","CASSETTE_NO":"51137463","SAMPLE_DT":"06/13/2011","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2011-06-13"},{"SOURCE_ROW_NUMBER":"162466","CASSETTE_NO":"51137548","SAMPLE_DT":"06/08/2011","QUARTZ_PCT":"08.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-06-08"},{"SOURCE_ROW_NUMBER":"161717","CASSETTE_NO":"57886919","SAMPLE_DT":"05/18/2011","QUARTZ_PCT":"07.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-05-18"},{"SOURCE_ROW_NUMBER":"52578","CASSETTE_NO":"57886944","SAMPLE_DT":"05/18/2011","QUARTZ_PCT":"09.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-05-18"},{"SOURCE_ROW_NUMBER":"26543","CASSETTE_NO":"57912012","SAMPLE_DT":"02/08/2011","QUARTZ_PCT":"05.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-02-08"},{"SOURCE_ROW_NUMBER":"27476","CASSETTE_NO":"57882636","SAMPLE_DT":"10/26/2010","QUARTZ_PCT":"01.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-10-26"},{"SOURCE_ROW_NUMBER":"15805","CASSETTE_NO":"57882551","SAMPLE_DT":"10/26/2010","QUARTZ_PCT":"02.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-10-26"},{"SOURCE_ROW_NUMBER":"39873","CASSETTE_NO":"57821565","SAMPLE_DT":"01/11/2010","QUARTZ_PCT":"05.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-01-11"},{"SOURCE_ROW_NUMBER":"135750","CASSETTE_NO":"57821395","SAMPLE_DT":"12/11/2009","QUARTZ_PCT":"05.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-12-11"},{"SOURCE_ROW_NUMBER":"5125","CASSETTE_NO":"57702578","SAMPLE_DT":"05/16/2008","QUARTZ_PCT":"04.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-05-16"},{"SOURCE_ROW_NUMBER":"7247","CASSETTE_NO":"57703206","SAMPLE_DT":"04/16/2008","QUARTZ_PCT":"04.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-04-16"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":1005,"firstDate":"2005-06-01","lastDate":"2011-11-28","metrics":{"ss":407,"amountDue":642004,"contested":330,"amountPaid":630223,"recentRows":0,"section104d":8,"unterminated":7,"proposedPenalty":1094338},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2874141","VIOLATION_NO":"4637302","VIOLATION_ISSUE_DT":"11/28/2011","SIG_SUB":"N","PART_SECTION":"77.208(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/29/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-11-28"},{"SOURCE_ROW_NUMBER":"2874140","VIOLATION_NO":"4637301","VIOLATION_ISSUE_DT":"11/28/2011","SIG_SUB":"Y","PART_SECTION":"75.523-2(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/29/2011","PROPOSED_PENALTY":"138","AMOUNT_DUE":"138","AMOUNT_PAID":"138","CONTESTED_IND":"N","sourceDate":"2011-11-28"},{"SOURCE_ROW_NUMBER":"2874143","VIOLATION_NO":"8125000","VIOLATION_ISSUE_DT":"11/18/2011","SIG_SUB":"N","PART_SECTION":"75.1107-16(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/18/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-11-18"},{"SOURCE_ROW_NUMBER":"2874142","VIOLATION_NO":"8124998","VIOLATION_ISSUE_DT":"10/27/2011","SIG_SUB":"N","PART_SECTION":"75.364(a)(2)(i)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/27/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-10-27"},{"SOURCE_ROW_NUMBER":"2874004","VIOLATION_NO":"7257540","VIOLATION_ISSUE_DT":"09/15/2011","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Highly","INJ_ILLNESS":"Fatal","NO_AFFECTED":"3","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"09/16/2011","PROPOSED_PENALTY":"142100","AMOUNT_DUE":"10000","AMOUNT_PAID":"10000","CONTESTED_IND":"N","sourceDate":"2011-09-15"},{"SOURCE_ROW_NUMBER":"2874003","VIOLATION_NO":"7257539","VIOLATION_ISSUE_DT":"08/30/2011","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"01/09/2012","CONTESTED_IND":"N","sourceDate":"2011-08-30"},{"SOURCE_ROW_NUMBER":"2873967","VIOLATION_NO":"8126005","VIOLATION_ISSUE_DT":"08/27/2011","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"08/31/2011","CONTESTED_IND":"N","sourceDate":"2011-08-27"},{"SOURCE_ROW_NUMBER":"2873992","VIOLATION_NO":"8139507","VIOLATION_ISSUE_DT":"08/25/2011","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"08/25/2011","CONTESTED_IND":"N","sourceDate":"2011-08-25"},{"SOURCE_ROW_NUMBER":"2873991","VIOLATION_NO":"8139506","VIOLATION_ISSUE_DT":"08/23/2011","SIG_SUB":"Y","PART_SECTION":"75.1101-6","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"20","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/25/2011","PROPOSED_PENALTY":"2901","AMOUNT_DUE":"2901","AMOUNT_PAID":"2901","CONTESTED_IND":"N","sourceDate":"2011-08-23"},{"SOURCE_ROW_NUMBER":"2873990","VIOLATION_NO":"8139505","VIOLATION_ISSUE_DT":"08/23/2011","SIG_SUB":"Y","PART_SECTION":"75.362(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/25/2011","PROPOSED_PENALTY":"224","AMOUNT_DUE":"224","AMOUNT_PAID":"224","CONTESTED_IND":"N","sourceDate":"2011-08-23"},{"SOURCE_ROW_NUMBER":"2873989","VIOLATION_NO":"8139504","VIOLATION_ISSUE_DT":"08/23/2011","SIG_SUB":"Y","PART_SECTION":"75.1722(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/23/2011","PROPOSED_PENALTY":"334","AMOUNT_DUE":"334","AMOUNT_PAID":"334","CONTESTED_IND":"N","sourceDate":"2011-08-23"},{"SOURCE_ROW_NUMBER":"2873988","VIOLATION_NO":"8139503","VIOLATION_ISSUE_DT":"08/22/2011","SIG_SUB":"Y","PART_SECTION":"75.523-2(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/25/2011","PROPOSED_PENALTY":"334","AMOUNT_DUE":"334","AMOUNT_PAID":"334","CONTESTED_IND":"N","sourceDate":"2011-08-22"}]}],"safety":{"href":"/api/v1/mines/4609082/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609082/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.208","heading":"Storage of materials.","id":"77.208","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.208","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Materials shall be stored and stacked in a manner which minimizes stumbling or fall-of-material hazards.\n\n(b) Materials that can create hazards if accidentally liberated from their containers shall be stored in a manner that minimizes the dangers.\n\n(c) Containers holding hazardous materials must be of a type approved for such use by recognized agencies.\n\n(d) Compressed and liquid gas cylinders shall be secured in a safe manner.\n\n(e) Valves on compressed gas cylinders shall be protected by covers when being transported or stored, and by a safe location when the cylinders are in use.\n\n[36 FR 9364, May 22, 1971, as amended at 67 FR 42389, June 21, 2002]","occurrenceCount":1},{"chapter":"I","heading":"Deenergization of self-propelled electric face equipment; performance requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-2","part":"75","subchapter":"O","subpart":"F","id":"75.523-2","citation":"30 CFR 75.523-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-16","heading":"Inspection of fire suppression devices.","id":"75.1107-16","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-16","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) All fire suppression devices shall be visually inspected at least once each week by a person qualified to make such inspections.\n\n(b) Each fire suppression device shall be tested and maintained in accordance with the requirements specified in the appropriate National Fire Code listed as follows for the type and kind of device used:\n\nNational Fire Code No. 11A “High Expansion Foam Systems” (NFPA No. 11A—1970). National Fire Code No. 13A “Care and Maintenance of Sprinkler Systems” (NFPA No. 13A—1971). National Fire Code No. 15 “Water Spray Fixed Systems for Fire Protection” (NFPA No. 15—1969). National Fire Code No. 17 “Dry Chemical Extinguishing Systems” (NFPA No. 17—1969). National Fire Code No. 72A “Local Protective Signaling Systems” (NFPA No. 72A—1967). National Fire Code No. 198 “Care of Fire Hose” (NFPA No. 198—1969).\n\n(c) A record of the inspections required by this section shall be maintained by the operator. The record of the weekly inspections may be maintained at an appropriate location by each fire suppression device.\n\n[37 FR 15304, July 29, 1972, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.364","heading":"Weekly examination.","id":"75.364","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.364","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Worked-out areas. (1) At least every 7 days, a certified person shall examine unsealed worked-out areas where no pillars have been recovered by traveling to the area of deepest penetration; measuring methane and oxygen concentrations and air quantities and making tests to determine if the air is moving in the proper direction in the area. The locations of measurement points where tests and measurements will be performed shall be included in the mine ventilation plan and shall be adequate in number and location to assure ventilation and air quality in the area. Air quantity measurements shall also be made where the air enters and leaves the worked-out area. An alternative method of evaluating the ventilation of the area may be approved in the ventilation plan.\n\n(2) At least every 7 days, a certified person shall evaluate the effectiveness of bleeder systems required by § 75.334 as follows:\n\n(i) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in its proper direction shall be made where air enters the worked-out area.\n\n(ii) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in the proper direction shall be made immediately before the air enters a return split of air.\n\n(iii) At least one entry of each set of bleeder entries used as part of a bleeder system under § 75.334 shall be traveled in its entirety. Measurements of methane and oxygen concentrations and air quantities and a test to determine if the air is moving in the proper direction shall be made at the measurement point locations specified in the mine ventilation plan to determine the effectiveness of the bleeder system.\n\n(iv) In lieu of the requirements of paragraphs (a)(2)(i) and (iii) of this section, an alternative method of evaluation may be specified in the ventilation plan provided the alternative method results in proper evaluation of the effectiveness of the bleeder system.\n\n(b) Hazardous conditions and violations of mandatory health or safety standards. At least every 7 days, an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(8) of this section shall be made by a certified person designated by the operator at the following locations:\n\n(1) In at least one entry of each intake air course, in its entirety, so that the entire air course is traveled.\n\n(2) In at least one entry of each return air course, in its entirety, so that the entire air course is traveled.\n\n(3) In each longwall or shortwall travelway in its entirety, so that the entire travelway is traveled.\n\n(4) At each seal along return and bleeder air courses and at each seal along intake air courses not examined under § 75.360(b)(5).\n\n(5) In each escapeway so that the entire escapeway is traveled.\n\n(6) On each working section not examined under § 75.360(b)(3) during the previous 7 days.\n\n(7) At each water pump not examined during a preshift examination conducted during the previous 7 days.\n\n(8) Weekly examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust; and\n\n(iv) § 75.1403—maintenance of off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) Measurements and tests. At least every 7 days, a certified person shall—\n\n(1) Determine the volume of air entering the main intakes and in each intake split;\n\n(2) Determine the volume of air and test for methane in the last open crosscut in any pair or set of developing entries or rooms, in the return of each split of air immediately before it enters the main returns, and where the air leaves the main returns; and\n\n(3) Test for methane in the return entry nearest each set of seals immediately after the air passes the seals.\n\n(d) Hazardous conditions shall be corrected immediately. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Any violation of the nine mandatory health or safety standards found during a weekly examination shall be corrected.\n\n(e) The weekly examination may be conducted at the same time as the preshift or on-shift examinations.\n\n(f) (1) The weekly examination is not required during any 7 day period in which no one enters any underground area of the mine.\n\n(2) Except for certified persons required to make examinations, no one shall enter any underground area of the mine if a weekly examination has not been completed within the previous 7 days.\n\n(g) Certification. The person making the weekly examinations shall certify by initials, date, and the time that the examination was made. Certifications and times shall appear at enough locations to show that the entire area has been examined.\n\n(h) Recordkeeping. At the completion of any shift during which a portion of a weekly examination is conducted, a record of the results of each weekly examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards found during each examination and their locations, the corrective action taken, and the results and location of air and methane measurements, shall be made. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the person making the examination or a person designated by the operator. If made by a person other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(i) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 77 FR 20715, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","heading":"Water sprinkler systems; general.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1101-6","part":"75","subchapter":"O","subpart":"L","id":"75.1101-6","citation":"30 CFR 75.1101-6","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.362","heading":"On-shift examination.","id":"75.362","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.362","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) At least once during each shift, or more often if necessary for safety, a certified person designated by the operator shall conduct an on-shift examination of each section where anyone is assigned to work during the shift and any area where mechanized mining equipment is being installed or removed during the shift. The certified person shall check for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (a)(3) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction.\n\n(2) A person designated by the operator shall conduct an examination and record the results and the corrective actions taken to assure compliance with the respirable dust control parameters specified in the approved mine ventilation plan. In those instances when a shift change is accomplished without an interruption in production on a section, the examination shall be made anytime within 1 hour after the shift change. In those instances when there is an interruption in production during the shift change, the examination shall be made before production begins on a section. Deficiencies in dust controls shall be corrected before production begins or resumes. The examination shall include: Air quantities and velocities; water pressures and flow rates; excessive leakage in the water delivery system; water spray numbers and orientations; section ventilation and control device placement; roof bolting machine dust collector vacuum levels; scrubber air flow rate; work practices required by the ventilation plan; and any other dust suppression measures. Measurements of the air velocity and quantity, water pressure and flow rates are not required if continuous monitoring of these controls is used and indicates that the dust controls are functioning properly.\n\n(3) On-shift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(b) During each shift that coal is produced, a certified person shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (a)(3) of this section along each belt conveyor haulageway where a belt conveyor is operated. This examination may be conducted at the same time as the preshift examination of belt conveyors and belt conveyor haulageways, if the examination is conducted within 3 hours before the oncoming shift.\n\n(c) Persons conducting the on-shift examination shall determine at the following locations:\n\n(1) The volume of air in the last open crosscut of each set of entries or rooms on each section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) The volume of air on a longwall or shortwall, including areas where longwall or shortwall equipment is being installed or removed, in the intake entry or entries at the intake end of the longwall or shortwall.\n\n(3) The velocity of air at each end of the longwall or shortwall face at the locations specified in the approved ventilation plan.\n\n(4) The volume of air at the intake end of any pillar line—\n\n(i) Where a single split of air is used in the intake entry furthest from the return air course immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) Where a split system is used in the intake entries of each split immediately inby the split point.\n\n(d) (1) A qualified person shall make tests for methane—\n\n(i) At the start of each shift at each working place before electrically operated equipment is energized; and\n\n(ii) Immediately before equipment is energized, taken into, or operated in a working place; and\n\n(iii) At 20-minute intervals, or more often if required in the approved ventilation plan at specific locations, during the operation of equipment in the working place.\n\n(2) Except as provided for in paragraph (d)(3) of this section, these methane tests shall be made at the face from under permanent roof support, using extendable probes or other acceptable means. When longwall or shortwall mining systems are used, these methane tests shall be made at the shearer, the plow, or the cutting head. When mining has been stopped for more than 20 minutes, methane tests shall be conducted prior to the start up of equipment.\n\n(3) As an alternative method of compliance with paragraph (d)(2) of this section during roof bolting, methane tests may be made by sweeping an area not less than 16 feet inby the last area of permanently supported roof, using a probe or other acceptable means. This method of testing is conditioned on meeting the following requirements:\n\n(i) The roof bolting machine must be equipped with an integral automated temporary roof support (ATRS) system that meets the requirements of 30 CFR 75.209.\n\n(ii) The roof bolting machine must have a permanently mounted, MSHA-approved methane monitor which meets the maintenance and calibration requirements of 30 CFR 75.342(a)(4), the warning signal requirements of 30 CFR 75.342(b), and the automatic de-energization requirements of 30 CFR 75.342(c).\n\n(iii) The methane monitor sensor must be mounted near the inby end and within 18 inches of the longitudinal center of the ATRS support, and positioned at least 12 inches from the roof when the ATRS is fully deployed.\n\n(iv) Manual methane tests must be made at intervals not exceeding 20 minutes. The test may be made either from under permanent roof support or from the roof bolter's work position protected by the deployed ATRS.\n\n(v) Once a methane test is made at the face, all subsequent methane tests in the same area of unsupported roof must also be made at the face, from under permanent roof support, using extendable probes or other acceptable means at intervals not exceeding 20 minutes.\n\n(vi) The district manager may require that the ventilation plan include the minimum air quantity and the position and placement of ventilation controls to be maintained during roof bolting.\n\n(e) If auxiliary fans and tubing are used, they shall be inspected frequently.\n\n(f) During each shift that coal is produced and at intervals not exceeding 4 hours, tests for methane shall be made by a certified person or by an atmospheric monitoring system (AMS) in each return split of air from each working section between the last working place, or longwall or shortwall face, ventilated by that split of air and the junction of the return air split with another air split, seal, or worked-out area. If auxiliary fans and tubing are used, the tests shall be made at a location outby the auxiliary fan discharge.\n\n(g) Certification. (1) The person conducting the on-shift examination in belt haulage entries shall certify by initials, date, and time that the examination was made. The certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(2) The certified person directing the on-shift examination to assure compliance with the respirable dust control parameters specified in the approved mine ventilation plan shall:\n\n(i) Certify by initials, date, and time on a board maintained at the section load-out or similar location showing that the examination was made prior to resuming production; and\n\n(ii) Verify, by initials and date, the record of the results of the examination required under (a)(2) of this section to assure compliance with the respirable dust control parameters specified in the mine ventilation plan. The verification shall be made no later than the end of the shift for which the examination was made.\n\n(3) The mine foreman or equivalent mine official shall countersign each examination record required under (a)(2) of this section after it is verified by the certified person under (g)(2)(ii) of this section, and no later than the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The record shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(4) Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 26442, May 28, 1996, as amended at 68 FR 40138, July 7, 2003; 77 FR 20715, Apr. 6, 2012; 79 FR 24987, May 1, 2014]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1722","heading":"Mechanical equipment guards.","id":"75.1722","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1722","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609082","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}