{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4609081","name":"Red Stag #1","status":"Abandoned","status_date":"2006-10-19","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Boone","nearest_town":"Prenter","operator_id":"P22186","operator_name":"Point Mining Inc","controller_id":"C14767","controller_name":"James Roy  Lucas","district":"C04","office":"Madison WV Field Office","employees":0,"latitude":37.996388,"longitude":-81.623055},"coverage":{"contributingSources":15,"registeredSources":20,"sourceRows":1014},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609081","name":"Red Stag #1"},"operator":{"type":"operator","id":"P22186","name":"Point Mining Inc"},"controller":{"type":"controller","id":"C14767","name":"James Roy  Lucas"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C14767","name":"James Roy  Lucas"},"object":{"type":"mine","id":"4609081","name":"Red Stag #1"},"validFrom":"1992-12-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609081|C14767|1992-12-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"mine","id":"4609081","name":"Red Stag #1"},"validFrom":"2004-12-09","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609081|C15833|2004-12-09|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0056457","name":"Jarrell's Branch Coal Company"},"object":{"type":"mine","id":"4609081","name":"Red Stag #1"},"validFrom":"2004-12-15","validTo":"2005-01-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609081|0056457|2004-12-15|2005-01-31"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"operator","id":"0056457","name":"Jarrell's Branch Coal Company"},"validFrom":"2004-12-15","validTo":"2005-01-31","current":false,"derived":true,"evidenceMineId":"4609081","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609081|0056457|2004-12-15|C15833|2004-12-09|97000"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22186","name":"Point Mining Inc"},"object":{"type":"mine","id":"4609081","name":"Red Stag #1"},"validFrom":"2005-02-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609081|P22186|2005-02-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14767","name":"James Roy  Lucas"},"object":{"type":"operator","id":"P22186","name":"Point Mining Inc"},"validFrom":"2005-02-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609081","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609081|P22186|2005-02-01|C14767|1992-12-01|93841"}}],"coverage":{"historyRecords":2,"edgeCount":6,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":9,"firstDate":"2005-05-13","lastDate":"2006-09-29","metrics":{"daysLost":235,"injuries":9,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"210440","DOCUMENT_NO":"220062780045","ACCIDENT_DT":"09/29/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"STEPPING OR KNEELING ON OBJECT","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"EE was unloading scoop outside that had water line on it, when he stepped on a piece of hiline cable laying on ground-twisted his right ankle. Went to dr an dmissed 1 shift.","sourceDate":"2006-09-29"},{"SOURCE_ROW_NUMBER":"145846","DOCUMENT_NO":"220062120064","ACCIDENT_DT":"07/20/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"226","NARRATIVE":"EE, general labor. Foot slipped on gob or rock & he twisted his right knee. Went to Dr & he is going to run an MRI to check knee. Doesn't know extent of injury or when he will return to work.","sourceDate":"2006-07-20"},{"SOURCE_ROW_NUMBER":"214788","DOCUMENT_NO":"220061790022","ACCIDENT_DT":"06/22/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"Employee was helping wind up belt rubber in roadway, hit his arm against guard and cut his forearm - small cut to lower forearm. He went to hospital, received first aid treatment (no sutures); missed one shift.","sourceDate":"2006-06-22"},{"SOURCE_ROW_NUMBER":"270627","DOCUMENT_NO":"220061700087","ACCIDENT_DT":"06/08/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"Beltman was cleaning gob out at tail area, had piece of drill steel prying on rock - hit bar against eye - resulting in laceration to head over right eye - went to hospital & got 5 sutures. Returned to work 6-12-06.","sourceDate":"2006-06-08"},{"SOURCE_ROW_NUMBER":"167450","DOCUMENT_NO":"220061560085","ACCIDENT_DT":"05/26/2006","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was helping set feeder, picked up a crib block that had a nail in it and punctured his right wrist. Got 2 sutures in wrist but missed no work.","sourceDate":"2006-05-26"},{"SOURCE_ROW_NUMBER":"188833","DOCUMENT_NO":"220060460026","ACCIDENT_DT":"02/08/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"Employee was helping rock dust, standing by scoop when operator went to move scoop and backed over his foot. He went to the hospital; big toe was broken.","sourceDate":"2006-02-08"},{"SOURCE_ROW_NUMBER":"137204","DOCUMENT_NO":"220053400025","ACCIDENT_DT":"12/01/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Bolter operator was loading bolt supplies on bolter when other bolter operator trammed bolter forward - ran wheel up on metatarsal boot on left foot, bruising foot.","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"266356","DOCUMENT_NO":"220053180100","ACCIDENT_DT":"11/08/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Absorption of radiations, caustics, toxic and noxious substances","OCCUPATION":"Stopping builder, Ventilation man, Mason man, Overcast","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"EE was plastering stopping by hand, when he splashed a little in right eye-causing irritation to eyes. Went to dr and got first aid treatment-he was off 2 days.","sourceDate":"2005-11-08"},{"SOURCE_ROW_NUMBER":"68403","DOCUMENT_NO":"220051400044","ACCIDENT_DT":"05/13/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"Employee was loading headers on roof bolter, slipped and fell and hurt his right wrist. He went to doctor; had wrist sprain. Was off two days.","sourceDate":"2005-05-13"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2006-10-19","lastDate":"2006-10-19","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":111,"firstDate":"2004-12-27","lastDate":"2006-09-26","metrics":{"ss":33,"delinquent":111,"recentRows":0,"paidPenalty":988,"proposedPenalty":27358,"currentAssessment":27358},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"821116","VIOLATION_NO":"7252167","ISSUE_DT":"09/26/2006","CFR_STANDARD_CD":"77.205(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"305.00","CURRENT_ASSESSMENT_AMT":"305.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-26"},{"SOURCE_ROW_NUMBER":"821115","VIOLATION_NO":"7252166","ISSUE_DT":"09/26/2006","CFR_STANDARD_CD":"75.364(g)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-26"},{"SOURCE_ROW_NUMBER":"821114","VIOLATION_NO":"7252165","ISSUE_DT":"09/26/2006","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"305.00","CURRENT_ASSESSMENT_AMT":"305.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-26"},{"SOURCE_ROW_NUMBER":"821119","VIOLATION_NO":"7256981","ISSUE_DT":"09/12/2006","CFR_STANDARD_CD":"75.360(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"6900.00","CURRENT_ASSESSMENT_AMT":"6900.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-12"},{"SOURCE_ROW_NUMBER":"821118","VIOLATION_NO":"7256980","ISSUE_DT":"09/12/2006","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"5300.00","CURRENT_ASSESSMENT_AMT":"5300.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-12"},{"SOURCE_ROW_NUMBER":"821117","VIOLATION_NO":"7256979","ISSUE_DT":"09/12/2006","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"6300.00","CURRENT_ASSESSMENT_AMT":"6300.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-12"},{"SOURCE_ROW_NUMBER":"818509","VIOLATION_NO":"7252392","ISSUE_DT":"05/25/2006","CFR_STANDARD_CD":"50.20(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-05-25"},{"SOURCE_ROW_NUMBER":"810149","VIOLATION_NO":"7249935","ISSUE_DT":"01/25/2006","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"144.00","CURRENT_ASSESSMENT_AMT":"144.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-01-25"},{"SOURCE_ROW_NUMBER":"810148","VIOLATION_NO":"7249934","ISSUE_DT":"01/20/2006","CFR_STANDARD_CD":"75.1107-16(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-01-20"},{"SOURCE_ROW_NUMBER":"810147","VIOLATION_NO":"7249933","ISSUE_DT":"01/20/2006","CFR_STANDARD_CD":"75.604(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-01-20"},{"SOURCE_ROW_NUMBER":"810146","VIOLATION_NO":"7249932","ISSUE_DT":"01/20/2006","CFR_STANDARD_CD":"75.523-2(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"268.00","CURRENT_ASSESSMENT_AMT":"268.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-01-20"},{"SOURCE_ROW_NUMBER":"810145","VIOLATION_NO":"7249931","ISSUE_DT":"01/20/2006","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-01-20"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":99,"firstDate":"2005-02-28","lastDate":"2006-09-07","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":14,"validSamples":85,"maxConcentration":36.628,"concentrationTotal":85.741},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"70626","CASS_NUM":"50866703","SMP_TAKEN_DT":"9/7/2006","CONC":".254","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-09-07"},{"SOURCE_ROW_NUMBER":"1185942","CASS_NUM":"50865740","SMP_TAKEN_DT":"8/25/2006","CONC":".136","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-08-25"},{"SOURCE_ROW_NUMBER":"541945","CASS_NUM":"50865785","SMP_TAKEN_DT":"8/24/2006","CONC":".375","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-08-24"},{"SOURCE_ROW_NUMBER":"303751","CASS_NUM":"50865704","SMP_TAKEN_DT":"8/23/2006","CONC":".092","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-08-23"},{"SOURCE_ROW_NUMBER":"1336574","CASS_NUM":"50866717","SMP_TAKEN_DT":"8/22/2006","CONC":".133","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-08-22"},{"SOURCE_ROW_NUMBER":"135206","CASS_NUM":"50866679","SMP_TAKEN_DT":"8/21/2006","CONC":".245","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-08-21"},{"SOURCE_ROW_NUMBER":"1383295","CASS_NUM":"50858533","SMP_TAKEN_DT":"7/10/2006","CONC":".053","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-07-10"},{"SOURCE_ROW_NUMBER":"414968","CASS_NUM":"50858554","SMP_TAKEN_DT":"6/17/2006","CONC":"36.628","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"CONTAMINATED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-17"},{"SOURCE_ROW_NUMBER":"776231","CASS_NUM":"50858581","SMP_TAKEN_DT":"6/16/2006","CONC":".071","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"194733","CASS_NUM":"50858564","SMP_TAKEN_DT":"6/14/2006","CONC":".235","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-14"},{"SOURCE_ROW_NUMBER":"1202093","CASS_NUM":"50858592","SMP_TAKEN_DT":"6/12/2006","CONC":".097","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-12"},{"SOURCE_ROW_NUMBER":"1549915","CASS_NUM":"50858535","SMP_TAKEN_DT":"6/9/2006","CONC":".316","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-09"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":5,"firstDate":"2005-03-03","lastDate":"2006-10-19","metrics":{"linkedIssuances":5},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":510,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":110,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2004-12-15","lastDate":"2005-02-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":13,"firstDate":"2004-12-09","lastDate":"2006-10-19","metrics":{"inspectors":28,"recentRows":0,"onSiteHours":391.25,"inspectionHours":627.75,"inspectionSamples":15},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"210044","EVENT_NO":"4114041","INSPECTION_BEGIN_DT":"10/19/2006","INSPECTION_END_DT":"10/19/2006","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2006-10-19"},{"SOURCE_ROW_NUMBER":"646270","EVENT_NO":"4114037","INSPECTION_BEGIN_DT":"09/11/2006","INSPECTION_END_DT":"09/12/2006","ACTIVITY_CODE":"E03","ACTIVITY":"103 (g) Written Notification Hazard Complaint Inspectio","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2006-09-11"},{"SOURCE_ROW_NUMBER":"54934","EVENT_NO":"4114036","INSPECTION_BEGIN_DT":"09/11/2006","INSPECTION_END_DT":"09/26/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"35.5","SUM_TOTAL_ON_SITE_HOURS":"25.75","sourceDate":"2006-09-11"},{"SOURCE_ROW_NUMBER":"1069096","EVENT_NO":"4113362","INSPECTION_BEGIN_DT":"04/12/2006","INSPECTION_END_DT":"07/03/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"25.25","SUM_TOTAL_ON_SITE_HOURS":"13","sourceDate":"2006-04-12"},{"SOURCE_ROW_NUMBER":"356161","EVENT_NO":"4111329","INSPECTION_BEGIN_DT":"02/02/2006","INSPECTION_END_DT":"02/14/2006","ACTIVITY_CODE":"E17","ACTIVITY":"Special Emphasis Programs","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2006-02-02"},{"SOURCE_ROW_NUMBER":"577568","EVENT_NO":"4111325","INSPECTION_BEGIN_DT":"01/03/2006","INSPECTION_END_DT":"01/31/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"94.5","SUM_TOTAL_ON_SITE_HOURS":"59","sourceDate":"2006-01-03"},{"SOURCE_ROW_NUMBER":"242192","EVENT_NO":"4111318","INSPECTION_BEGIN_DT":"10/04/2005","INSPECTION_END_DT":"10/27/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"71","SUM_TOTAL_ON_SITE_HOURS":"51","sourceDate":"2005-10-04"},{"SOURCE_ROW_NUMBER":"360781","EVENT_NO":"4112259","INSPECTION_BEGIN_DT":"07/11/2005","INSPECTION_END_DT":"08/30/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"134.25","SUM_TOTAL_ON_SITE_HOURS":"77.25","sourceDate":"2005-07-11"},{"SOURCE_ROW_NUMBER":"795998","EVENT_NO":"4112254","INSPECTION_BEGIN_DT":"06/01/2005","INSPECTION_END_DT":"06/01/2005","ACTIVITY_CODE":"E24","ACTIVITY":"Other Technical Compliance Investigations","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2005-06-01"},{"SOURCE_ROW_NUMBER":"733480","EVENT_NO":"4109192","INSPECTION_BEGIN_DT":"04/04/2005","INSPECTION_END_DT":"06/13/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"7","SUM_TOTAL_INSP_HOURS":"183.25","SUM_TOTAL_ON_SITE_HOURS":"122.75","sourceDate":"2005-04-04"},{"SOURCE_ROW_NUMBER":"824066","EVENT_NO":"4108601","INSPECTION_BEGIN_DT":"03/15/2005","INSPECTION_END_DT":"03/22/2005","ACTIVITY_CODE":"BBA","ACTIVITY":"ELECTRICAL INVESTIGATION","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"22","SUM_TOTAL_ON_SITE_HOURS":"13","sourceDate":"2005-03-15"},{"SOURCE_ROW_NUMBER":"23741","EVENT_NO":"4109187","INSPECTION_BEGIN_DT":"02/28/2005","INSPECTION_END_DT":"03/01/2005","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2005-02-28"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":21,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2006-Q4":{"hours":0,"employees":0,"production":0},"2006-Q3":{"hours":8100,"employees":23,"production":33201},"2006-Q2":{"hours":12913,"employees":25,"production":25798},"2006-Q1":{"hours":5456,"employees":33,"production":10384},"2005-Q4":{"hours":16530,"employees":28,"production":48909},"2005-Q3":{"hours":19463,"employees":39,"production":55165},"2005-Q2":{"hours":15670,"employees":38,"production":47012}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2005":{"hours":51663,"employees":35,"production":151086},"2006":{"hours":26469,"employees":28,"production":69383}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":5,"firstDate":"2005-08-10","lastDate":"2005-08-10","metrics":{"recentRows":0,"doseOver100":2,"actDoseTotal":381,"pelDoseTotal":325},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"254069","EVENT_NO":"4112259","SURVEY_DATE":"08/10/2005","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"5","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2005-08-10"},{"SOURCE_ROW_NUMBER":"254068","EVENT_NO":"4112259","SURVEY_DATE":"08/10/2005","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"112","PEL_DOSE_90":"110","SURVEY_TYPE":"I","sourceDate":"2005-08-10"},{"SOURCE_ROW_NUMBER":"254067","EVENT_NO":"4112259","SURVEY_DATE":"08/10/2005","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"65","PEL_DOSE_90":"43","SURVEY_TYPE":"I","sourceDate":"2005-08-10"},{"SOURCE_ROW_NUMBER":"254066","EVENT_NO":"4112259","SURVEY_DATE":"08/10/2005","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"63","PEL_DOSE_90":"43","SURVEY_TYPE":"I","sourceDate":"2005-08-10"},{"SOURCE_ROW_NUMBER":"254065","EVENT_NO":"4112259","SURVEY_DATE":"08/10/2005","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"136","PEL_DOSE_90":"128","SURVEY_TYPE":"I","sourceDate":"2005-08-10"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":8,"firstDate":"2005-05-18","lastDate":"2006-04-24","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":12.9,"validSamples":8,"quartzPctTotal":86.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"89563","CASSETTE_NO":"57637319","SAMPLE_DT":"04/24/2006","QUARTZ_PCT":"10.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-04-24"},{"SOURCE_ROW_NUMBER":"30618","CASSETTE_NO":"57637380","SAMPLE_DT":"04/24/2006","QUARTZ_PCT":"11.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-04-24"},{"SOURCE_ROW_NUMBER":"125263","CASSETTE_NO":"57568259","SAMPLE_DT":"10/20/2005","QUARTZ_PCT":"12.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-10-20"},{"SOURCE_ROW_NUMBER":"77542","CASSETTE_NO":"57568268","SAMPLE_DT":"10/20/2005","QUARTZ_PCT":"10.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-10-20"},{"SOURCE_ROW_NUMBER":"154898","CASSETTE_NO":"50773344","SAMPLE_DT":"08/30/2005","QUARTZ_PCT":"09.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-08-30"},{"SOURCE_ROW_NUMBER":"35120","CASSETTE_NO":"57504094","SAMPLE_DT":"08/09/2005","QUARTZ_PCT":"12.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-08-09"},{"SOURCE_ROW_NUMBER":"83836","CASSETTE_NO":"57503886","SAMPLE_DT":"05/18/2005","QUARTZ_PCT":"07.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-05-18"},{"SOURCE_ROW_NUMBER":"82214","CASSETTE_NO":"57503903","SAMPLE_DT":"05/18/2005","QUARTZ_PCT":"12.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-05-18"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":113,"firstDate":"2004-12-09","lastDate":"2006-09-26","metrics":{"ss":34,"amountDue":27358,"contested":0,"amountPaid":988,"recentRows":0,"section104d":3,"unterminated":0,"proposedPenalty":27358},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2872099","VIOLATION_NO":"7252167","VIOLATION_ISSUE_DT":"09/26/2006","SIG_SUB":"Y","PART_SECTION":"77.205(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/19/2006","PROPOSED_PENALTY":"305","AMOUNT_DUE":"305","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2006-09-26"},{"SOURCE_ROW_NUMBER":"2872098","VIOLATION_NO":"7252166","VIOLATION_ISSUE_DT":"09/26/2006","SIG_SUB":"N","PART_SECTION":"75.364(g)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/26/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2006-09-26"},{"SOURCE_ROW_NUMBER":"2872097","VIOLATION_NO":"7252165","VIOLATION_ISSUE_DT":"09/26/2006","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/26/2006","PROPOSED_PENALTY":"305","AMOUNT_DUE":"305","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2006-09-26"},{"SOURCE_ROW_NUMBER":"2872102","VIOLATION_NO":"7256981","VIOLATION_ISSUE_DT":"09/12/2006","SIG_SUB":"Y","PART_SECTION":"75.360(a)(1)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"5","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"09/14/2006","PROPOSED_PENALTY":"6900","AMOUNT_DUE":"6900","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2006-09-12"},{"SOURCE_ROW_NUMBER":"2872101","VIOLATION_NO":"7256980","VIOLATION_ISSUE_DT":"09/12/2006","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"09/14/2006","PROPOSED_PENALTY":"5300","AMOUNT_DUE":"5300","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2006-09-12"},{"SOURCE_ROW_NUMBER":"2872100","VIOLATION_NO":"7256979","VIOLATION_ISSUE_DT":"09/12/2006","SIG_SUB":"Y","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"5","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"09/14/2006","PROPOSED_PENALTY":"6300","AMOUNT_DUE":"6300","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2006-09-12"},{"SOURCE_ROW_NUMBER":"2872068","VIOLATION_NO":"7252392","VIOLATION_ISSUE_DT":"05/25/2006","SIG_SUB":"N","PART_SECTION":"50.20(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/30/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2006-05-25"},{"SOURCE_ROW_NUMBER":"2872031","VIOLATION_NO":"7249935","VIOLATION_ISSUE_DT":"01/25/2006","SIG_SUB":"Y","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/26/2006","PROPOSED_PENALTY":"144","AMOUNT_DUE":"144","AMOUNT_PAID":"144","CONTESTED_IND":"N","sourceDate":"2006-01-25"},{"SOURCE_ROW_NUMBER":"2872030","VIOLATION_NO":"7249934","VIOLATION_ISSUE_DT":"01/20/2006","SIG_SUB":"N","PART_SECTION":"75.1107-16(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/20/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2006-01-20"},{"SOURCE_ROW_NUMBER":"2872029","VIOLATION_NO":"7249933","VIOLATION_ISSUE_DT":"01/20/2006","SIG_SUB":"N","PART_SECTION":"75.604(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/20/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2006-01-20"},{"SOURCE_ROW_NUMBER":"2872028","VIOLATION_NO":"7249932","VIOLATION_ISSUE_DT":"01/20/2006","SIG_SUB":"Y","PART_SECTION":"75.523-2(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/20/2006","PROPOSED_PENALTY":"268","AMOUNT_DUE":"268","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2006-01-20"},{"SOURCE_ROW_NUMBER":"2872027","VIOLATION_NO":"7249931","VIOLATION_ISSUE_DT":"01/20/2006","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/20/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2006-01-20"}]}],"safety":{"href":"/api/v1/mines/4609081/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609081/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.205","heading":"Travelways at surface installations.","id":"77.205","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.205","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Safe means of access shall be provided and maintained to all working places.\n\n(b) Travelways and platforms or other means of access to areas where persons are required to travel or work, shall be kept clear of all extraneous material and other stumbling or slipping hazards.\n\n(c) Inclined travelways shall be constructed of nonskid material or equipped with cleats.\n\n(d) Regularly used travelways shall be sanded, salted, or cleared of snow and ice as soon as practicable.\n\n(e) Crossovers, elevated walkways, elevated ramps, and stairways shall be of substantial construction, provided with handrails, and maintained in good condition. Where necessary toeboards shall be provided.\n\n(f) Crossovers shall be provided where it is necessary to cross conveyors.\n\n(g) Moving conveyors shall be crossed only at designated crossover points.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.364","heading":"Weekly examination.","id":"75.364","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.364","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Worked-out areas. (1) At least every 7 days, a certified person shall examine unsealed worked-out areas where no pillars have been recovered by traveling to the area of deepest penetration; measuring methane and oxygen concentrations and air quantities and making tests to determine if the air is moving in the proper direction in the area. The locations of measurement points where tests and measurements will be performed shall be included in the mine ventilation plan and shall be adequate in number and location to assure ventilation and air quality in the area. Air quantity measurements shall also be made where the air enters and leaves the worked-out area. An alternative method of evaluating the ventilation of the area may be approved in the ventilation plan.\n\n(2) At least every 7 days, a certified person shall evaluate the effectiveness of bleeder systems required by § 75.334 as follows:\n\n(i) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in its proper direction shall be made where air enters the worked-out area.\n\n(ii) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in the proper direction shall be made immediately before the air enters a return split of air.\n\n(iii) At least one entry of each set of bleeder entries used as part of a bleeder system under § 75.334 shall be traveled in its entirety. Measurements of methane and oxygen concentrations and air quantities and a test to determine if the air is moving in the proper direction shall be made at the measurement point locations specified in the mine ventilation plan to determine the effectiveness of the bleeder system.\n\n(iv) In lieu of the requirements of paragraphs (a)(2)(i) and (iii) of this section, an alternative method of evaluation may be specified in the ventilation plan provided the alternative method results in proper evaluation of the effectiveness of the bleeder system.\n\n(b) Hazardous conditions and violations of mandatory health or safety standards. At least every 7 days, an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(8) of this section shall be made by a certified person designated by the operator at the following locations:\n\n(1) In at least one entry of each intake air course, in its entirety, so that the entire air course is traveled.\n\n(2) In at least one entry of each return air course, in its entirety, so that the entire air course is traveled.\n\n(3) In each longwall or shortwall travelway in its entirety, so that the entire travelway is traveled.\n\n(4) At each seal along return and bleeder air courses and at each seal along intake air courses not examined under § 75.360(b)(5).\n\n(5) In each escapeway so that the entire escapeway is traveled.\n\n(6) On each working section not examined under § 75.360(b)(3) during the previous 7 days.\n\n(7) At each water pump not examined during a preshift examination conducted during the previous 7 days.\n\n(8) Weekly examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust; and\n\n(iv) § 75.1403—maintenance of off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) Measurements and tests. At least every 7 days, a certified person shall—\n\n(1) Determine the volume of air entering the main intakes and in each intake split;\n\n(2) Determine the volume of air and test for methane in the last open crosscut in any pair or set of developing entries or rooms, in the return of each split of air immediately before it enters the main returns, and where the air leaves the main returns; and\n\n(3) Test for methane in the return entry nearest each set of seals immediately after the air passes the seals.\n\n(d) Hazardous conditions shall be corrected immediately. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Any violation of the nine mandatory health or safety standards found during a weekly examination shall be corrected.\n\n(e) The weekly examination may be conducted at the same time as the preshift or on-shift examinations.\n\n(f) (1) The weekly examination is not required during any 7 day period in which no one enters any underground area of the mine.\n\n(2) Except for certified persons required to make examinations, no one shall enter any underground area of the mine if a weekly examination has not been completed within the previous 7 days.\n\n(g) Certification. The person making the weekly examinations shall certify by initials, date, and the time that the examination was made. Certifications and times shall appear at enough locations to show that the entire area has been examined.\n\n(h) Recordkeeping. At the completion of any shift during which a portion of a weekly examination is conducted, a record of the results of each weekly examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards found during each examination and their locations, the corrective action taken, and the results and location of air and methane measurements, shall be made. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the person making the examination or a person designated by the operator. If made by a person other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(i) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 77 FR 20715, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1725","heading":"Machinery and equipment; operation and maintenance.","id":"75.1725","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1725","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.360","heading":"Preshift examination at fixed intervals.","id":"75.360","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.360","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) Except as provided in paragraph (a)(2) of this section, a certified person designated by the operator must make a preshift examination within 3 hours preceding the beginning of any 8-hour interval during which any person is scheduled to work or travel underground. No person other than certified examiners may enter or remain in any underground area unless a preshift examination has been completed for the established 8-hour interval. The operator must establish 8-hour intervals of time subject to the required preshift examinations.\n\n(2) Preshift examinations of areas where pumpers are scheduled to work or travel shall not be required prior to the pumper entering the areas if the pumper is a certified person and the pumper conducts an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, tests for methane and oxygen deficiency, and determines if the air is moving in its proper direction in the area where the pumper works or travels. The examination of the area must be completed before the pumper performs any other work. A record of all hazardous conditions and violations of the mandatory health or safety standards found by the pumper shall be made and retained in accordance with § 75.363 of this part.\n\n(b) The person conducting the preshift examination shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction at the following locations:\n\n(1) Roadways, travelways and track haulageways where persons are scheduled, prior to the beginning of the preshift examination, to work or travel during the oncoming shift.\n\n(2) Belt conveyors that will be used to transport persons during the oncoming shift and the entries in which these belt conveyors are located.\n\n(3) Working sections and areas where mechanized mining equipment is being installed or removed, if anyone is scheduled to work on the section or in the area during the oncoming shift. The scope of the examination shall include the working places, approaches to worked-out areas and ventilation controls on these sections and in these areas, and the examination shall include tests of the roof, face and rib conditions on these sections and in these areas.\n\n(4) Approaches to worked-out areas along intake air courses and at the entries used to carry air into worked-out areas if the intake air passing the approaches is used to ventilate working sections where anyone is scheduled to work during the oncoming shift. The examination of the approaches to the worked-out areas shall be made in the intake air course immediately inby and outby each entry used to carry air into the worked-out area. An examination of the entries used to carry air into the worked-out areas shall be conducted at a point immediately inby the intersection of each entry with the intake air course.\n\n(5) Seals along intake air courses where intake air passes by a seal to ventilate working sections where anyone is scheduled to work during the oncoming shift.\n\n(6)(i) Entries and rooms developed after November 15, 1992, and developed more than 2 crosscuts off an intake air course without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift; and,\n\n(ii) Entries and rooms developed after November 15, 1992, and driven more than 20 feet off an intake air course without a crosscut and without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift.\n\n(7) Areas where trolley wires or trolley feeder wires are to be or will remain energized during the oncoming shift.\n\n(8) High spots along intake air courses where methane is likely to accumulate, if equipment will be operated in the area during the shift.\n\n(9) Underground electrical installations referred to in § 75.340(a), except those pumps listed in § 75.340 (b)(2) through (b)(6), and areas where compressors subject to § 75.344 are installed if the electrical installation or compressor is or will be energized during the shift.\n\n(10) Other areas where work or travel during the oncoming shift is scheduled prior to the beginning of the preshift examination.\n\n(11) Preshift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) The person conducting the preshift examination shall determine the volume of air entering each of the following areas if anyone is scheduled to work in the areas during the oncoming shift:\n\n(1) In the last open crosscut of each set of entries or rooms on each working section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) On each longwall or shortwall in the intake entry or entries at the intake end of the longwall or shortwall face immediately outby the face and the velocity of air at each end of the face at the locations specified in the approved ventilation plan.\n\n(3) At the intake end of any pillar line—\n\n(i) If a single split of air is used, in the intake entry furthest from the return air course, immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) If a split system is used, in the intake entries of each split immediately inby the split point.\n\n(d) The person conducting the preshift examination shall check the refuge alternative for damage, the integrity of the tamper-evident seal and the mechanisms required to deploy the refuge alternative, and the ready availability of compressed oxygen and air.\n\n(e) The district manager may require the operator to examine other areas of the mine or examine for other hazards and violations of other mandatory health or safety standards found during the preshift examination.\n\n(f) Certification. At each working place examined, the person doing the preshift examination shall certify by initials, date, and the time, that the examination was made. In areas required to be examined outby a working section, the certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(g) Recordkeeping. A record of the results of each preshift examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards and their locations found by the examiner during each examination, and of the results and locations of air and methane measurements, shall be made on the surface before any persons, other than certified persons conducting examinations required by this subpart, enter any underground area of the mine. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the certified person who made the examination or by a person designated by the operator. If the record is made by someone other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. A record shall also be made by a certified person of the action taken to correct hazardous conditions and violations of mandatory health or safety standards found during the preshift examination. All preshift and corrective action records shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(h) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 62 FR 35085, June 30, 1997; 64 FR 45170, Aug. 19, 1999; 73 FR 80697, Dec. 31, 2008; 77 FR 20714, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1},{"chapter":"I","heading":"Preparation and submission of MSHA Report Form 7000-1—Mine Accident, Injury, and Illness Report.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-I/part-50/subpart-C/section-50.20","part":"50","subchapter":"I","subpart":"C","id":"50.20","citation":"30 CFR 50.20","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER I—ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND PRODUCTION IN MINES","partHeading":"PART 50—NOTIFICATION, INVESTIGATION, REPORTS AND RECORDS OF ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND COAL PRODUCTION IN MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-16","heading":"Inspection of fire suppression devices.","id":"75.1107-16","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-16","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) All fire suppression devices shall be visually inspected at least once each week by a person qualified to make such inspections.\n\n(b) Each fire suppression device shall be tested and maintained in accordance with the requirements specified in the appropriate National Fire Code listed as follows for the type and kind of device used:\n\nNational Fire Code No. 11A “High Expansion Foam Systems” (NFPA No. 11A—1970). National Fire Code No. 13A “Care and Maintenance of Sprinkler Systems” (NFPA No. 13A—1971). National Fire Code No. 15 “Water Spray Fixed Systems for Fire Protection” (NFPA No. 15—1969). National Fire Code No. 17 “Dry Chemical Extinguishing Systems” (NFPA No. 17—1969). National Fire Code No. 72A “Local Protective Signaling Systems” (NFPA No. 72A—1967). National Fire Code No. 198 “Care of Fire Hose” (NFPA No. 198—1969).\n\n(c) A record of the inspections required by this section shall be maintained by the operator. The record of the weekly inspections may be maintained at an appropriate location by each fire suppression device.\n\n[37 FR 15304, July 29, 1972, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.604","heading":"Permanent splicing of trailing cables.","id":"75.604","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.604","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"[Statutory Provisions]\n\nWhen permanent splices in trailing cables are made, they shall be:\n\n(a) Mechanically strong with adequate electrical conductivity and flexibility;\n\n(b) Effectively insulated and sealed so as to exclude moisture; and\n\n(c) Vulcanized or otherwise treated with suitable materials to provide flame-resistant qualities and good bonding to the outer jacket.\n\n(d) Made using splice kits accepted or approved by MSHA as flame resistant.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 57 FR 61223, Dec. 23, 1992]","occurrenceCount":1},{"chapter":"I","heading":"Deenergization of self-propelled electric face equipment; performance requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-2","part":"75","subchapter":"O","subpart":"F","id":"75.523-2","citation":"30 CFR 75.523-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609081","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}