{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4609038","name":"No. 4","status":"Abandoned and Sealed","status_date":"2010-09-28","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Mingo","nearest_town":"Varney","operator_id":"P21850","operator_name":"Wayco Limited Partnership No. 1","controller_id":"C14544","controller_name":"James O  Bunn; Franklin D  Robertson","district":"C04","office":"Beckley District","employees":0,"latitude":37.652222,"longitude":-82.009166},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":1076},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609038","name":"No. 4"},"operator":{"type":"operator","id":"P21850","name":"Wayco Limited Partnership No. 1"},"controller":{"type":"controller","id":"C14544","name":"James O  Bunn; Franklin D  Robertson"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C14544","name":"Franklin D  Robertson  et al"},"object":{"type":"mine","id":"4609038","name":"No. 4"},"validFrom":"1992-01-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609038|C14544|1992-01-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0052542","name":"Hi-Tech Construction Co Inc"},"object":{"type":"mine","id":"4609038","name":"No. 4"},"validFrom":"2004-05-05","validTo":"2004-08-16","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609038|0052542|2004-05-05|2004-08-16"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0043391","name":"Carl D  Runyon"},"object":{"type":"mine","id":"4609038","name":"No. 4"},"validFrom":"2004-05-05","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609038|0043391|2004-05-05|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0043391","name":"Carl D  Runyon"},"object":{"type":"operator","id":"0052542","name":"Hi-Tech Construction Co Inc"},"validFrom":"2004-05-05","validTo":"2004-08-16","current":false,"derived":true,"evidenceMineId":"4609038","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609038|0052542|2004-05-05|0043391|2004-05-05|4617"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P21850","name":"Wayco Limited Partnership No. 1"},"object":{"type":"mine","id":"4609038","name":"No. 4"},"validFrom":"2004-08-17","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609038|P21850|2004-08-17|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14544","name":"Franklin D  Robertson  et al"},"object":{"type":"operator","id":"P21850","name":"Wayco Limited Partnership No. 1"},"validFrom":"2004-08-17","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609038","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609038|P21850|2004-08-17|C14544|1992-01-01|93154"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14544","name":"James O  Bunn  et al"},"object":{"type":"operator","id":"P21850","name":"Wayco Limited Partnership No. 1"},"validFrom":"2004-08-17","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609038","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609038|P21850|2004-08-17|C14544|1992-01-01|93155"}}],"coverage":{"historyRecords":3,"edgeCount":7,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":8,"firstDate":"2005-01-26","lastDate":"2007-08-31","metrics":{"daysLost":538,"injuries":5,"fatalities":0,"recentRows":0,"restrictedDays":1,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"145831","DOCUMENT_NO":"220072550024","ACCIDENT_DT":"08/31/2007","DEGREE_INJURY":"PERM TOT OR PERM PRTL DISABLTY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Beltman was busting rock with sledge hammer & picking up rock he felt pain in his groin area.","sourceDate":"2007-08-31"},{"SOURCE_ROW_NUMBER":"236302","DOCUMENT_NO":"220072190034","ACCIDENT_DT":"07/24/2007","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Operator was tramming s.c. to face, car hit hole in mine floor jamming back.","sourceDate":"2007-07-24"},{"SOURCE_ROW_NUMBER":"34102","DOCUMENT_NO":"220071690035","ACCIDENT_DT":"05/29/2007","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Lifting 2 bags of rock dust, strained back.","sourceDate":"2007-05-29"},{"SOURCE_ROW_NUMBER":"154505","DOCUMENT_NO":"220071140067","ACCIDENT_DT":"04/14/2007","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Fall of roof #5 entry, 1 br inby spad 497. Date mined 4-15-06. Slicken sides, longwall pressure. 3000 feet from working section. No airways or escapeways were affected. 9 cribs and 16 timbers were set around the fall.","sourceDate":"2007-04-14"},{"SOURCE_ROW_NUMBER":"68387","DOCUMENT_NO":"220062630035","ACCIDENT_DT":"09/12/2006","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"At spad 473 in return airway, a fall was found while return airway was being made.","sourceDate":"2006-09-12"},{"SOURCE_ROW_NUMBER":"68386","DOCUMENT_NO":"220052840066","ACCIDENT_DT":"09/21/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"186","NARRATIVE":"A small piece of draw rock fell, ap. 8\" dia. x 1/2\" thick striking employee on neck.","sourceDate":"2005-09-21"},{"SOURCE_ROW_NUMBER":"4000","DOCUMENT_NO":"220050540044","ACCIDENT_DT":"02/14/2005","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"WATER IN ROOF. FALL WAS IN #5 ENTRY BETWEEN SPAD 100 & 106. CALLED REPORT IN LOGAN OFFICE 8:05 AM.","sourceDate":"2005-02-14"},{"SOURCE_ROW_NUMBER":"184633","DOCUMENT_NO":"220050420039","ACCIDENT_DT":"01/26/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by rolling or sliding object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"352","NARRATIVE":"WHILE CUTTING CROSS CUT FROM #2 TO #1, RIB OF #2 ROLLED OFF STRIKING EMPLOYEE IN THE BACK.","sourceDate":"2005-01-26"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2010-09-28","lastDate":"2010-09-28","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":190,"firstDate":"2004-12-09","lastDate":"2007-07-19","metrics":{"ss":61,"delinquent":170,"recentRows":0,"paidPenalty":65597,"proposedPenalty":67539,"currentAssessment":67539},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"821384","VIOLATION_NO":"7250172","ISSUE_DT":"07/19/2007","CFR_STANDARD_CD":"50.20(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-07-19"},{"SOURCE_ROW_NUMBER":"827114","VIOLATION_NO":"7266011","ISSUE_DT":"07/11/2007","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1203.00","CURRENT_ASSESSMENT_AMT":"1203.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-07-11"},{"SOURCE_ROW_NUMBER":"827113","VIOLATION_NO":"7266010","ISSUE_DT":"07/10/2007","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"5080.00","CURRENT_ASSESSMENT_AMT":"5080.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-07-10"},{"SOURCE_ROW_NUMBER":"827112","VIOLATION_NO":"7266009","ISSUE_DT":"07/10/2007","CFR_STANDARD_CD":"75.1107-13(g)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"207.00","CURRENT_ASSESSMENT_AMT":"207.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-07-10"},{"SOURCE_ROW_NUMBER":"827111","VIOLATION_NO":"7266008","ISSUE_DT":"07/10/2007","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1657.00","CURRENT_ASSESSMENT_AMT":"1657.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-07-10"},{"SOURCE_ROW_NUMBER":"830395","VIOLATION_NO":"7270131","ISSUE_DT":"06/21/2007","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1530.00","CURRENT_ASSESSMENT_AMT":"1530.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-06-21"},{"SOURCE_ROW_NUMBER":"830394","VIOLATION_NO":"7270130","ISSUE_DT":"06/21/2007","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1530.00","CURRENT_ASSESSMENT_AMT":"1530.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-06-21"},{"SOURCE_ROW_NUMBER":"830393","VIOLATION_NO":"7270129","ISSUE_DT":"06/19/2007","CFR_STANDARD_CD":"75.904","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"308.00","CURRENT_ASSESSMENT_AMT":"308.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-06-19"},{"SOURCE_ROW_NUMBER":"830392","VIOLATION_NO":"7270128","ISSUE_DT":"06/19/2007","CFR_STANDARD_CD":"75.516","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1530.00","CURRENT_ASSESSMENT_AMT":"1530.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-06-19"},{"SOURCE_ROW_NUMBER":"830391","VIOLATION_NO":"7270127","ISSUE_DT":"06/19/2007","CFR_STANDARD_CD":"75.516","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1530.00","CURRENT_ASSESSMENT_AMT":"1530.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-06-19"},{"SOURCE_ROW_NUMBER":"830390","VIOLATION_NO":"7270124","ISSUE_DT":"06/19/2007","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"687.00","CURRENT_ASSESSMENT_AMT":"687.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-06-19"},{"SOURCE_ROW_NUMBER":"830389","VIOLATION_NO":"7270123","ISSUE_DT":"06/19/2007","CFR_STANDARD_CD":"75.1107-16(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"308.00","CURRENT_ASSESSMENT_AMT":"308.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-06-19"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":5,"firstDate":"2007-12-18","lastDate":"2008-06-27","metrics":{"appeals":0,"decisions":5,"recentRows":0,"decisionPenalty":1381,"originalPenalty":1381},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"199014","VIOLATION_NO":"7263339","DOCKET_NO":"WEVA 2007-427","DECISION_DT":"06/27/2008","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"217.00","DECISION_PENALTY_AMT":"217.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2008-06-27"},{"SOURCE_ROW_NUMBER":"199013","VIOLATION_NO":"7263340","DOCKET_NO":"WEVA 2007-426","DECISION_DT":"06/27/2008","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"350.00","DECISION_PENALTY_AMT":"350.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2008-06-27"},{"SOURCE_ROW_NUMBER":"10607","VIOLATION_NO":"7265098","DOCKET_NO":"WEVA 2007-427","DECISION_DT":"06/27/2008","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"217.00","DECISION_PENALTY_AMT":"217.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2008-06-27"},{"SOURCE_ROW_NUMBER":"10606","VIOLATION_NO":"7263337","DOCKET_NO":"WEVA 2007-426","DECISION_DT":"06/27/2008","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"350.00","DECISION_PENALTY_AMT":"350.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2008-06-27"},{"SOURCE_ROW_NUMBER":"196190","VIOLATION_NO":"7255133","DOCKET_NO":"WEVA 2007-267","DECISION_DT":"12/18/2007","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"247.00","DECISION_PENALTY_AMT":"247.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2007-12-18"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":162,"firstDate":"2004-10-28","lastDate":"2007-07-25","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":8,"validSamples":154,"maxConcentration":7.153,"concentrationTotal":92.566},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"404052","CASS_NUM":"50907653","SMP_TAKEN_DT":"7/25/2007","CONC":".907","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-07-25"},{"SOURCE_ROW_NUMBER":"328339","CASS_NUM":"50907668","SMP_TAKEN_DT":"7/24/2007","CONC":"1.817","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-07-24"},{"SOURCE_ROW_NUMBER":"216947","CASS_NUM":"50907644","SMP_TAKEN_DT":"7/24/2007","CONC":".475","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-07-24"},{"SOURCE_ROW_NUMBER":"136795","CASS_NUM":"50907654","SMP_TAKEN_DT":"7/20/2007","CONC":"1.111","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-07-20"},{"SOURCE_ROW_NUMBER":"165394","CASS_NUM":"50907667","SMP_TAKEN_DT":"7/19/2007","CONC":".766","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-07-19"},{"SOURCE_ROW_NUMBER":"1478504","CASS_NUM":"57632759","SMP_TAKEN_DT":"6/13/2007","CONC":"1.129","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-13"},{"SOURCE_ROW_NUMBER":"1165543","CASS_NUM":"57632765","SMP_TAKEN_DT":"6/13/2007","CONC":".056","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-13"},{"SOURCE_ROW_NUMBER":"1152711","CASS_NUM":"57632795","SMP_TAKEN_DT":"6/13/2007","CONC":".204","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-13"},{"SOURCE_ROW_NUMBER":"740900","CASS_NUM":"57632776","SMP_TAKEN_DT":"6/13/2007","CONC":".021","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-13"},{"SOURCE_ROW_NUMBER":"401434","CASS_NUM":"57632760","SMP_TAKEN_DT":"6/13/2007","CONC":".629","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-13"},{"SOURCE_ROW_NUMBER":"376111","CASS_NUM":"57632790","SMP_TAKEN_DT":"6/13/2007","CONC":".011","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INSUFFICIENT DUST OBSERVED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-13"},{"SOURCE_ROW_NUMBER":"793742","CASS_NUM":"50911132","SMP_TAKEN_DT":"5/29/2007","CONC":".465","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-05-29"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":37,"firstDate":"2007-03-01","lastDate":"2007-06-22","metrics":{"linkedIssuances":37},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":5,"firstDate":"2006-09-05","lastDate":"2007-02-12","metrics":{"decisions":5,"ssChanged":1,"recentRows":0,"decisionPenalty":1381,"proposedPenalty":1381},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"397649","CITATION_NO":"7265098","CITATION_ISSUE_DT":"02/12/2007","DOCKET_NO":"WEVA 2007-427","DECISION_DT":"06/27/2008","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"217.00","DECISION_PENALTY_AMT":"217.00","sourceDate":"2007-02-12"},{"SOURCE_ROW_NUMBER":"400171","CITATION_NO":"7263337","CITATION_ISSUE_DT":"12/18/2006","DOCKET_NO":"WEVA 2007-426","DECISION_DT":"06/27/2008","CFR_STANDARD_CODE":"75.903","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"350.00","DECISION_PENALTY_AMT":"350.00","sourceDate":"2006-12-18"},{"SOURCE_ROW_NUMBER":"228237","CITATION_NO":"7263339","CITATION_ISSUE_DT":"12/18/2006","DOCKET_NO":"WEVA 2007-427","DECISION_DT":"06/27/2008","CFR_STANDARD_CODE":"75.340(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"217.00","DECISION_PENALTY_AMT":"217.00","sourceDate":"2006-12-18"},{"SOURCE_ROW_NUMBER":"115666","CITATION_NO":"7263340","CITATION_ISSUE_DT":"12/18/2006","DOCKET_NO":"WEVA 2007-426","DECISION_DT":"06/27/2008","CFR_STANDARD_CODE":"75.703","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"350.00","DECISION_PENALTY_AMT":"350.00","sourceDate":"2006-12-18"},{"SOURCE_ROW_NUMBER":"227629","CITATION_NO":"7255133","CITATION_ISSUE_DT":"09/05/2006","DOCKET_NO":"WEVA 2007-267","DECISION_DT":"12/18/2007","CFR_STANDARD_CODE":"75.520","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"247.00","DECISION_PENALTY_AMT":"247.00","sourceDate":"2006-09-05"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":328,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":80,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"2004-05-05","lastDate":"2004-08-17","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":22,"firstDate":"2004-09-03","lastDate":"2007-10-03","metrics":{"inspectors":31,"recentRows":0,"onSiteHours":640.75,"inspectionHours":1074.25,"inspectionSamples":100},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"961939","EVENT_NO":"4115683","INSPECTION_BEGIN_DT":"10/03/2007","INSPECTION_END_DT":"10/03/2007","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2007-10-03"},{"SOURCE_ROW_NUMBER":"1064722","EVENT_NO":"4114123","INSPECTION_BEGIN_DT":"07/19/2007","INSPECTION_END_DT":"07/19/2007","ACTIVITY_CODE":"E25","ACTIVITY":"Part 50 Audit","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2007-07-19"},{"SOURCE_ROW_NUMBER":"283032","EVENT_NO":"4115488","INSPECTION_BEGIN_DT":"07/05/2007","INSPECTION_END_DT":"07/12/2007","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"30","SUM_TOTAL_ON_SITE_HOURS":"19.5","sourceDate":"2007-07-05"},{"SOURCE_ROW_NUMBER":"1049047","EVENT_NO":"4116131","INSPECTION_BEGIN_DT":"05/30/2007","INSPECTION_END_DT":"06/28/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"58.5","SUM_TOTAL_ON_SITE_HOURS":"37","sourceDate":"2007-05-30"},{"SOURCE_ROW_NUMBER":"768090","EVENT_NO":"4116132","INSPECTION_BEGIN_DT":"05/30/2007","INSPECTION_END_DT":"06/01/2007","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"19.5","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2007-05-30"},{"SOURCE_ROW_NUMBER":"670189","EVENT_NO":"4116121","INSPECTION_BEGIN_DT":"02/08/2007","INSPECTION_END_DT":"02/12/2007","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.5","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2007-02-08"},{"SOURCE_ROW_NUMBER":"453800","EVENT_NO":"4116114","INSPECTION_BEGIN_DT":"01/08/2007","INSPECTION_END_DT":"03/09/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"104.5","SUM_TOTAL_ON_SITE_HOURS":"60.25","sourceDate":"2007-01-08"},{"SOURCE_ROW_NUMBER":"491567","EVENT_NO":"4116058","INSPECTION_BEGIN_DT":"10/26/2006","INSPECTION_END_DT":"12/21/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"63.5","SUM_TOTAL_ON_SITE_HOURS":"50.25","sourceDate":"2006-10-26"},{"SOURCE_ROW_NUMBER":"386865","EVENT_NO":"4115157","INSPECTION_BEGIN_DT":"08/28/2006","INSPECTION_END_DT":"09/29/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"71.5","SUM_TOTAL_ON_SITE_HOURS":"43.5","sourceDate":"2006-08-28"},{"SOURCE_ROW_NUMBER":"39874","EVENT_NO":"4113335","INSPECTION_BEGIN_DT":"06/14/2006","INSPECTION_END_DT":"06/14/2006","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2006-06-14"},{"SOURCE_ROW_NUMBER":"496545","EVENT_NO":"4113217","INSPECTION_BEGIN_DT":"04/07/2006","INSPECTION_END_DT":"05/31/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"157","SUM_TOTAL_ON_SITE_HOURS":"82.5","sourceDate":"2006-04-07"},{"SOURCE_ROW_NUMBER":"286927","EVENT_NO":"4111429","INSPECTION_BEGIN_DT":"01/04/2006","INSPECTION_END_DT":"03/30/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"97.25","SUM_TOTAL_ON_SITE_HOURS":"54","sourceDate":"2006-01-04"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":30,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2007-Q4":{"hours":0,"employees":0,"production":0},"2007-Q3":{"hours":11225,"employees":19,"production":46953},"2007-Q2":{"hours":16581,"employees":25,"production":64975},"2007-Q1":{"hours":18847,"employees":33,"production":60323},"2006-Q4":{"hours":17940,"employees":34,"production":51323},"2006-Q3":{"hours":19470,"employees":32,"production":62160},"2006-Q2":{"hours":15902,"employees":29,"production":58772},"2006-Q1":{"hours":15165,"employees":26,"production":40129},"2005-Q4":{"hours":17093,"employees":23,"production":50753},"2005-Q3":{"hours":15137,"employees":25,"production":50549},"2005-Q2":{"hours":14524,"employees":27,"production":72626},"2005-Q1":{"hours":13851,"employees":24,"production":66607}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":8,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2004":{"hours":13567,"employees":26,"production":39669},"2005":{"hours":60605,"employees":25,"production":240535},"2006":{"hours":68477,"employees":30,"production":212384},"2007":{"hours":46653,"employees":26,"production":172251}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":5,"firstDate":"2005-02-02","lastDate":"2007-05-22","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":24.1,"validSamples":5,"quartzPctTotal":49.3},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"35912","CASSETTE_NO":"50911142","SAMPLE_DT":"05/22/2007","QUARTZ_PCT":"24.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-05-22"},{"SOURCE_ROW_NUMBER":"45338","CASSETTE_NO":"50871510","SAMPLE_DT":"10/10/2006","QUARTZ_PCT":"05.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-10-10"},{"SOURCE_ROW_NUMBER":"100730","CASSETTE_NO":"57611619","SAMPLE_DT":"03/27/2006","QUARTZ_PCT":"08.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-03-27"},{"SOURCE_ROW_NUMBER":"133951","CASSETTE_NO":"57541763","SAMPLE_DT":"04/14/2005","QUARTZ_PCT":"06.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-04-14"},{"SOURCE_ROW_NUMBER":"34212","CASSETTE_NO":"57528501","SAMPLE_DT":"02/02/2005","QUARTZ_PCT":"05.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-02-02"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":191,"firstDate":"2004-12-09","lastDate":"2007-07-19","metrics":{"ss":61,"amountDue":67539,"contested":5,"amountPaid":65597,"recentRows":0,"section104d":6,"unterminated":0,"proposedPenalty":67539},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2858270","VIOLATION_NO":"7250172","VIOLATION_ISSUE_DT":"07/19/2007","SIG_SUB":"N","PART_SECTION":"50.20(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/19/2007","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2007-07-19"},{"SOURCE_ROW_NUMBER":"2858264","VIOLATION_NO":"7266011","VIOLATION_ISSUE_DT":"07/11/2007","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/12/2007","PROPOSED_PENALTY":"1203","AMOUNT_DUE":"1203","AMOUNT_PAID":"1203","CONTESTED_IND":"N","sourceDate":"2007-07-11"},{"SOURCE_ROW_NUMBER":"2858263","VIOLATION_NO":"7266010","VIOLATION_ISSUE_DT":"07/10/2007","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/11/2007","PROPOSED_PENALTY":"5080","AMOUNT_DUE":"5080","AMOUNT_PAID":"5080","CONTESTED_IND":"N","sourceDate":"2007-07-10"},{"SOURCE_ROW_NUMBER":"2858262","VIOLATION_NO":"7266009","VIOLATION_ISSUE_DT":"07/10/2007","SIG_SUB":"N","PART_SECTION":"75.1107-13(g)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/10/2007","PROPOSED_PENALTY":"207","AMOUNT_DUE":"207","AMOUNT_PAID":"207","CONTESTED_IND":"N","sourceDate":"2007-07-10"},{"SOURCE_ROW_NUMBER":"2858261","VIOLATION_NO":"7266008","VIOLATION_ISSUE_DT":"07/10/2007","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"7","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/11/2007","PROPOSED_PENALTY":"1657","AMOUNT_DUE":"1657","AMOUNT_PAID":"1657","CONTESTED_IND":"N","sourceDate":"2007-07-10"},{"SOURCE_ROW_NUMBER":"2858260","VIOLATION_NO":"7270131","VIOLATION_ISSUE_DT":"06/21/2007","SIG_SUB":"Y","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/27/2007","PROPOSED_PENALTY":"1530","AMOUNT_DUE":"1530","AMOUNT_PAID":"1530","CONTESTED_IND":"N","sourceDate":"2007-06-21"},{"SOURCE_ROW_NUMBER":"2858259","VIOLATION_NO":"7270130","VIOLATION_ISSUE_DT":"06/21/2007","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/27/2007","PROPOSED_PENALTY":"1530","AMOUNT_DUE":"1530","AMOUNT_PAID":"1530","CONTESTED_IND":"N","sourceDate":"2007-06-21"},{"SOURCE_ROW_NUMBER":"2858258","VIOLATION_NO":"7270129","VIOLATION_ISSUE_DT":"06/19/2007","SIG_SUB":"N","PART_SECTION":"75.904","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/21/2007","PROPOSED_PENALTY":"308","AMOUNT_DUE":"308","AMOUNT_PAID":"308","CONTESTED_IND":"N","sourceDate":"2007-06-19"},{"SOURCE_ROW_NUMBER":"2858257","VIOLATION_NO":"7270128","VIOLATION_ISSUE_DT":"06/19/2007","SIG_SUB":"Y","PART_SECTION":"75.516","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/19/2007","PROPOSED_PENALTY":"1530","AMOUNT_DUE":"1530","AMOUNT_PAID":"1530","CONTESTED_IND":"N","sourceDate":"2007-06-19"},{"SOURCE_ROW_NUMBER":"2858256","VIOLATION_NO":"7270127","VIOLATION_ISSUE_DT":"06/19/2007","SIG_SUB":"Y","PART_SECTION":"75.516","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/19/2007","PROPOSED_PENALTY":"1530","AMOUNT_DUE":"1530","AMOUNT_PAID":"1530","CONTESTED_IND":"N","sourceDate":"2007-06-19"},{"SOURCE_ROW_NUMBER":"2858255","VIOLATION_NO":"7270124","VIOLATION_ISSUE_DT":"06/19/2007","SIG_SUB":"Y","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/19/2007","PROPOSED_PENALTY":"687","AMOUNT_DUE":"687","AMOUNT_PAID":"687","CONTESTED_IND":"N","sourceDate":"2007-06-19"},{"SOURCE_ROW_NUMBER":"2858254","VIOLATION_NO":"7270123","VIOLATION_ISSUE_DT":"06/19/2007","SIG_SUB":"N","PART_SECTION":"75.1107-16(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/19/2007","PROPOSED_PENALTY":"308","AMOUNT_DUE":"308","AMOUNT_PAID":"308","CONTESTED_IND":"N","sourceDate":"2007-06-19"}]}],"safety":{"href":"/api/v1/mines/4609038/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609038/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Preparation and submission of MSHA Report Form 7000-1—Mine Accident, Injury, and Illness Report.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-I/part-50/subpart-C/section-50.20","part":"50","subchapter":"I","subpart":"C","id":"50.20","citation":"30 CFR 50.20","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER I—ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND PRODUCTION IN MINES","partHeading":"PART 50—NOTIFICATION, INVESTIGATION, REPORTS AND RECORDS OF ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND COAL PRODUCTION IN MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-13","heading":"Approval of other fire suppression devices.","id":"75.1107-13","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-13","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Notwithstanding the provisions of §§ 75.1107-1 through 75.1107-12 the District Manager for the District in which the mine is located may approve any other fire suppression system or device which provides substantially equivalent protection as would be achieved through compliance with those sections: Provided, That no such system or device shall be approved which does not meet the following minimum criteria:\n\n(a) Components shall be approved by the Secretary, or where appropriate be listed as approved by a nationally recognized agency approved by the Secretary.\n\n(b) The fire suppression equipment shall be designed to withstand the rigors of the mine environment. Where used, pressure vessels shall conform with the requirements of section 3603, 3606, 3607, 3707, and 3708 of National Fire Code No. 22 “Water Tanks for Private Fire Protection” (NFPA No. 22-1971).\n\n(c) The cover of hose of fire suppression devices, if used on the protected equipment, shall meet the flame-resistant requirements of Part 18 of this chapter (Bureau of Mines Schedule 2G).\n\n(d) Extinguishing agents shall not create a serious toxic or other hazard to the miners.\n\n(e) The electrical components of the fire suppression device shall meet the requirements for electrical components of the mining machine.\n\n(f) Where used, manual actuators for initiating the operation of the fire suppression device shall be readily accessible to the machine operator. On unattended equipment, an automatic as well as a manual actuator shall be provided.\n\n(g) On unattended equipment the fire suppression device shall operate independently of the power to the main motor (or equivalent) so it will remain operative if the circuit breakers (or other protective device) actuates. On attended equipment powered through a trailing cable the fire suppression device shall operate independently of the electrical power provided by the cable.\n\n(h) On unattended equipment, the sensor system shall have a means for checking its operative condition.\n\n(i) The fire suppression agent shall be directed at locations where the greatest potential fire hazard exists. Cable reel compartments shall receive approximately twice the quantity of extinguishing agent as each other hazardous location.\n\n(j) The rate of application of the fire suppression agent shall minimize the time for quenching and the total quantity applied shall be sufficient to quench a fire in its incipient stage.\n\n(k) The effectiveness of the quenching agent, together with the total quantity of agent and its rate of application shall provide equivalent protection to the water, dry powder, or foam systems described in §§ 75.1107-7, 75.1107-9, and 75.1107-10.\n\n(l) The fire suppression device shall be operable at all times electrical power is connected to the mining machine, except during tramming when the machine is in a ventilated passageway, the water hose if used, may be switched from one hydrant to another in a reasonable time and except in systems meeting the minimum special criteria set forth in paragraph (m) of this section.\n\n(m) Systems for attended equipment which are not continuously connected to a water supply shall not be approved unless they meet the following minimum criteria:\n\n(1) The machine shall be equipped with a firehose at least 50 feet in length which is continuously connected to the machine-mounted portion of the system.\n\n(2) Hydrants in proximity to the area where the machine is to be used shall be equipped with sufficient hose to reach the machine at any time it is connected to a power source.\n\n(3) The machine shall be used only where the operator (or other person) will always be in ventilated air uncontaminated by smoke and hot gases from the machine fire while extending the machine-mounted hose to connect with the hydrant-mounted hose.\n\n(4) The machine and hydrant hoses shall be readily accessible so that the connection between the machine-mounted hose and the hydrant hose can be made and water flow achieved in not more than 3 minutes under actual mining conditions for any location of the machine while electric power is connected.\n\n(5) The rate of water flow at the machine shall provide a minimum of 0.12 gallon of water per minute per square foot of top surface area (excluding conveyors, cutters, and gathering heads). The water shall discharge to all hazardous locations on the machine.\n\n(6) Hose, if used on the machine, in addition to meeting the flame resistant requirements for the cover of a hose provided in §§ 75.1107-3(b) and 75.1107-13(c) shall have a minimum burst pressure 4 times that of the static water pressure at the mining machine. Fabric braid hose shall have at least two braids, and wire braid hose shall have at least a single braid.\n\n(7) In addition to the hose located at the hydrant (which is intended to be connected to the hose on the machine) the firefighting equipment required by § 75.1100-2(a) shall be maintained.\n\n(8) A sufficient number of trained miners shall be kept on the section when the machine is in use to connect the machine hose to the hydrant hose and achieve water flow in not more than 3 minutes.\n\n[37 FR 15303, July 29, 1972]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.904","heading":"Identification of circuit breakers.","id":"75.904","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-J/section-75.904","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"J","subpartHeading":"Subpart J—Underground Low- and Medium-Voltage Alternating Current Circuits","text":"[Statutory Provisions]\n\nCircuit breakers shall be marked for identification.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.516","heading":"Power wires; support.","id":"75.516","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.516","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll power wires (except trailing cables on mobile equipment, specially designed cables conducting high-voltage power to underground rectifying equipment or transformers, or bare or insulated ground and return wires) shall be supported on well-insulated insulators and shall not contact combustible material, roof, or ribs.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-16","heading":"Inspection of fire suppression devices.","id":"75.1107-16","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-16","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) All fire suppression devices shall be visually inspected at least once each week by a person qualified to make such inspections.\n\n(b) Each fire suppression device shall be tested and maintained in accordance with the requirements specified in the appropriate National Fire Code listed as follows for the type and kind of device used:\n\nNational Fire Code No. 11A “High Expansion Foam Systems” (NFPA No. 11A—1970). National Fire Code No. 13A “Care and Maintenance of Sprinkler Systems” (NFPA No. 13A—1971). National Fire Code No. 15 “Water Spray Fixed Systems for Fire Protection” (NFPA No. 15—1969). National Fire Code No. 17 “Dry Chemical Extinguishing Systems” (NFPA No. 17—1969). National Fire Code No. 72A “Local Protective Signaling Systems” (NFPA No. 72A—1967). National Fire Code No. 198 “Care of Fire Hose” (NFPA No. 198—1969).\n\n(c) A record of the inspections required by this section shall be maintained by the operator. The record of the weekly inspections may be maintained at an appropriate location by each fire suppression device.\n\n[37 FR 15304, July 29, 1972, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609038","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}