{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"4609029","name":"Mountaineer II Mine","status":"Active","status_date":"2006-03-27","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Logan","nearest_town":"Sharples","operator_id":"P21148","operator_name":"Mingo Logan Coal LLC","controller_id":"0189840","controller_name":"Core Natural Resources Inc","district":"C04","office":"Logan WV Field Office","employees":310,"latitude":37.911944,"longitude":-81.798611},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":48162},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609029","name":"Mountaineer II Mine"},"operator":{"type":"operator","id":"P21148","name":"Mingo Logan Coal LLC"},"controller":{"type":"controller","id":"0189840","name":"Core Natural Resources Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00012","name":"Ashland Inc et al"},"object":{"type":"mine","id":"4609029","name":"Mountaineer II Mine"},"validFrom":"1990-01-24","validTo":"1996-06-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609029|C00012|1990-01-24|1996-06-30"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15561","name":"Arch Resources Inc"},"object":{"type":"mine","id":"4609029","name":"Mountaineer II Mine"},"validFrom":"1997-07-01","validTo":"2025-01-13","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609029|C15561|1997-07-01|2025-01-13"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P21148","name":"Mingo Logan Coal LLC"},"object":{"type":"mine","id":"4609029","name":"Mountaineer II Mine"},"validFrom":"2004-03-25","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609029|P21148|2004-03-25|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00012","name":"Ashland Inc et al"},"object":{"type":"operator","id":"P21148","name":"Mingo Logan Coal LLC"},"validFrom":"2004-03-25","validTo":"1996-06-30","current":false,"derived":true,"evidenceMineId":"4609029","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609029|P21148|2004-03-25|C00012|1990-01-24|43469"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15561","name":"Arch Resources Inc"},"object":{"type":"operator","id":"P21148","name":"Mingo Logan Coal LLC"},"validFrom":"2004-03-25","validTo":"2025-01-13","current":false,"derived":true,"evidenceMineId":"4609029","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609029|P21148|2004-03-25|C15561|1997-07-01|96045"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0189840","name":"Core Natural Resources Inc"},"object":{"type":"mine","id":"4609029","name":"Mountaineer II Mine"},"validFrom":"2025-01-14","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609029|0189840|2025-01-14|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0189840","name":"Core Natural Resources Inc"},"object":{"type":"operator","id":"P21148","name":"Mingo Logan Coal LLC"},"validFrom":"2025-01-14","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609029","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609029|P21148|2004-03-25|0189840|2025-01-14|40491"}}],"coverage":{"historyRecords":3,"edgeCount":7,"intervalAnomalies":1,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":366,"firstDate":"2004-12-06","lastDate":"2026-08-10","metrics":{"daysLost":20519,"injuries":251,"fatalities":4,"recentRows":51,"restrictedDays":677,"contractorRecords":82},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"38421","DOCUMENT_NO":"220262330001","ACCIDENT_DT":"08/10/2026","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"An unplanned roof fall has occurred on the West Mains at 5 crosscut #5 entry.","sourceDate":"2026-08-10"},{"SOURCE_ROW_NUMBER":"77116","DOCUMENT_NO":"220262320020","ACCIDENT_DT":"08/06/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Master mechanic, Foreman, Supervisor","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was operating a roof bolter when they turned around and struck their elbow on the boom of the ATRS.","sourceDate":"2026-08-06"},{"SOURCE_ROW_NUMBER":"167443","DOCUMENT_NO":"220262150012","ACCIDENT_DT":"07/27/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","NARRATIVE":"Employee was operating a roof bolter when EE pinched EE's finger.","sourceDate":"2026-07-27"},{"SOURCE_ROW_NUMBER":"38420","DOCUMENT_NO":"220262020010","ACCIDENT_DT":"07/10/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","NARRATIVE":"Employee was removing a rub rail from a continuous mining machine when the rub rail came down on top of the employee's left foot.","sourceDate":"2026-07-10"},{"SOURCE_ROW_NUMBER":"253485","DOCUMENT_NO":"220262520010","ACCIDENT_DT":"06/11/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"23","NARRATIVE":"Employee was dragging a 4\" waterline when EE stepped in a hole and twisted EE's knee. Employee returned to work until EE was placed off work by a doctor on 8/24/2026.","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"197408","DOCUMENT_NO":"220261320026","ACCIDENT_DT":"04/30/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","NARRATIVE":"Employee was walking ahead of a scoop when EE bent over to tie EE's boots and EE's foot was ran over by a scoop tire.","sourceDate":"2026-04-30"},{"SOURCE_ROW_NUMBER":"262170","DOCUMENT_NO":"220261110031","ACCIDENT_DT":"04/01/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"24","NARRATIVE":"Employee was placing glue in the tray of the roof bolter when a rock fell from the roof striking their right foot. Employee was placed off work on 4/13/26.","sourceDate":"2026-04-01"},{"SOURCE_ROW_NUMBER":"158816","DOCUMENT_NO":"220260990026","ACCIDENT_DT":"03/30/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"14","NARRATIVE":"Employee was reaching a piece of 4\" discharge line across the beltline when the pipe slipped and pinched the right index finger against the belt structure.","sourceDate":"2026-03-30"},{"SOURCE_ROW_NUMBER":"193160","DOCUMENT_NO":"220260550012","ACCIDENT_DT":"02/11/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"Employee was hanging curtain at the roof bolt machine when they were struck by a rock measuring approximately 32\" wide by 65\" long by 1-4\" thick.","sourceDate":"2026-02-11"},{"SOURCE_ROW_NUMBER":"253484","DOCUMENT_NO":"220260550013","ACCIDENT_DT":"02/10/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Master mechanic, Foreman, Supervisor","NO_INJURIES":"1","DAYS_LOST":"67","NARRATIVE":"Employee was helping move cm cable over when they felt pain in their left foot.","sourceDate":"2026-02-10"},{"SOURCE_ROW_NUMBER":"38419","DOCUMENT_NO":"220253170683","ACCIDENT_DT":"11/03/2025","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"An unplanned roof fall occurred on 2 Gas Mainline 3 section at 38 crosscut, #3 intersection, in the last open break.","sourceDate":"2025-11-03"},{"SOURCE_ROW_NUMBER":"236307","DOCUMENT_NO":"220253170274","ACCIDENT_DT":"10/02/2025","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"An unplanned roof fall occurred in the West Mains Return, #3 entry between 7&8 cross cut. Approximately 20'x75'x6'","sourceDate":"2025-10-02"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2006-03-27","lastDate":"2006-03-27","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":7146,"firstDate":"2004-11-30","lastDate":"2026-08-28","metrics":{"ss":1556,"delinquent":6845,"recentRows":2245,"paidPenalty":4547248,"proposedPenalty":6862922.1,"currentAssessment":5357619},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"3001395","VIOLATION_NO":"5134512","ISSUE_DT":"08/28/2026","CFR_STANDARD_CD":"75.514","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"755.00","CURRENT_ASSESSMENT_AMT":"755.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-28"},{"SOURCE_ROW_NUMBER":"3001394","VIOLATION_NO":"5134511","ISSUE_DT":"08/28/2026","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"398.00","CURRENT_ASSESSMENT_AMT":"398.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-28"},{"SOURCE_ROW_NUMBER":"3001393","VIOLATION_NO":"5134510","ISSUE_DT":"08/28/2026","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"504.00","CURRENT_ASSESSMENT_AMT":"504.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-28"},{"SOURCE_ROW_NUMBER":"3001278","VIOLATION_NO":"5096349","ISSUE_DT":"08/28/2026","CFR_STANDARD_CD":"75.604(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-28"},{"SOURCE_ROW_NUMBER":"3001276","VIOLATION_NO":"5094515","ISSUE_DT":"08/28/2026","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"245.00","CURRENT_ASSESSMENT_AMT":"245.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-28"},{"SOURCE_ROW_NUMBER":"3001392","VIOLATION_NO":"5134509","ISSUE_DT":"08/27/2026","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"177.00","CURRENT_ASSESSMENT_AMT":"177.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-27"},{"SOURCE_ROW_NUMBER":"3001391","VIOLATION_NO":"5134508","ISSUE_DT":"08/27/2026","CFR_STANDARD_CD":"75.1106-2(a)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"226.00","CURRENT_ASSESSMENT_AMT":"226.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-27"},{"SOURCE_ROW_NUMBER":"3001390","VIOLATION_NO":"5134507","ISSUE_DT":"08/27/2026","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1219.00","CURRENT_ASSESSMENT_AMT":"1219.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-27"},{"SOURCE_ROW_NUMBER":"3001389","VIOLATION_NO":"5134506","ISSUE_DT":"08/27/2026","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"432.00","CURRENT_ASSESSMENT_AMT":"432.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-27"},{"SOURCE_ROW_NUMBER":"2952523","VIOLATION_NO":"5134312","ISSUE_DT":"08/27/2026","CFR_STANDARD_CD":"75.333(d)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"226.00","CURRENT_ASSESSMENT_AMT":"226.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-27"},{"SOURCE_ROW_NUMBER":"3001323","VIOLATION_NO":"5132873","ISSUE_DT":"08/25/2026","CFR_STANDARD_CD":"75.333(c)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-25"},{"SOURCE_ROW_NUMBER":"3001322","VIOLATION_NO":"5132872","ISSUE_DT":"08/25/2026","CFR_STANDARD_CD":"75.604(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"336.00","CURRENT_ASSESSMENT_AMT":"336.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-25"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":2475,"firstDate":"2005-09-06","lastDate":"2026-07-13","metrics":{"appeals":10,"decisions":2320,"recentRows":909,"decisionPenalty":2983719,"originalPenalty":4559978.1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"468062","VIOLATION_NO":"5132439","DOCKET_NO":"WEVA 2026-0264","DECISION_DT":"07/13/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1550.00","DECISION_PENALTY_AMT":"697.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-07-13"},{"SOURCE_ROW_NUMBER":"468061","VIOLATION_NO":"5132432","DOCKET_NO":"WEVA 2026-0264","DECISION_DT":"07/13/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2133.00","DECISION_PENALTY_AMT":"193.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-07-13"},{"SOURCE_ROW_NUMBER":"468060","VIOLATION_NO":"5095201","DOCKET_NO":"WEVA 2026-0264","DECISION_DT":"07/13/2026","DECISION_TYPE_CODE_DESC":"Vacate","ORIGINAL_PENALTY_AMT":"3448.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2026-07-13"},{"SOURCE_ROW_NUMBER":"467804","VIOLATION_NO":"5132440","DOCKET_NO":"WEVA 2026-0264","DECISION_DT":"07/13/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"7676.00","DECISION_PENALTY_AMT":"2312.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-07-13"},{"SOURCE_ROW_NUMBER":"467803","VIOLATION_NO":"5095206","DOCKET_NO":"WEVA 2026-0264","DECISION_DT":"07/13/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1431.00","DECISION_PENALTY_AMT":"432.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-07-13"},{"SOURCE_ROW_NUMBER":"467280","VIOLATION_NO":"5095207","DOCKET_NO":"WEVA 2026-0264","DECISION_DT":"07/13/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"7084.00","DECISION_PENALTY_AMT":"7084.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-07-13"},{"SOURCE_ROW_NUMBER":"226992","VIOLATION_NO":"5132109","DOCKET_NO":"WEVA 2026-0264","DECISION_DT":"07/13/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1431.00","DECISION_PENALTY_AMT":"1431.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-07-13"},{"SOURCE_ROW_NUMBER":"226058","VIOLATION_NO":"5132443","DOCKET_NO":"WEVA 2026-0264","DECISION_DT":"07/13/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1320.00","DECISION_PENALTY_AMT":"151.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-07-13"},{"SOURCE_ROW_NUMBER":"226057","VIOLATION_NO":"5095202","DOCKET_NO":"WEVA 2026-0264","DECISION_DT":"07/13/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2133.00","DECISION_PENALTY_AMT":"2133.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-07-13"},{"SOURCE_ROW_NUMBER":"225786","VIOLATION_NO":"5132431","DOCKET_NO":"WEVA 2026-0264","DECISION_DT":"07/13/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"465.00","DECISION_PENALTY_AMT":"209.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-07-13"},{"SOURCE_ROW_NUMBER":"466684","VIOLATION_NO":"5095861","DOCKET_NO":"WEVA 2026-0166","DECISION_DT":"05/14/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2133.00","DECISION_PENALTY_AMT":"151.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-05-14"},{"SOURCE_ROW_NUMBER":"466046","VIOLATION_NO":"5096518","DOCKET_NO":"WEVA 2026-0166","DECISION_DT":"05/14/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"697.00","DECISION_PENALTY_AMT":"697.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-05-14"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":18899,"firstDate":"2006-03-30","lastDate":"2026-10-14","metrics":{"recentRows":10280,"cpdmSamples":13757,"voidSamples":6217,"validSamples":12682,"maxConcentration":110897.414,"concentrationTotal":169343.078},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"3032817","SMP_TAKEN_DT":"10/14/2026","CONC":"1.443","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-14"},{"SOURCE_ROW_NUMBER":"3032496","SMP_TAKEN_DT":"10/14/2026","CONC":".485","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-14"},{"SOURCE_ROW_NUMBER":"2606146","SMP_TAKEN_DT":"10/14/2026","CONC":".301","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-14"},{"SOURCE_ROW_NUMBER":"2520223","SMP_TAKEN_DT":"10/14/2026","CONC":".445","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-14"},{"SOURCE_ROW_NUMBER":"2434353","SMP_TAKEN_DT":"10/14/2026","CONC":".729","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-14"},{"SOURCE_ROW_NUMBER":"2178307","SMP_TAKEN_DT":"10/14/2026","CONC":".78","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-14"},{"SOURCE_ROW_NUMBER":"1922223","SMP_TAKEN_DT":"10/14/2026","CONC":".189","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-14"},{"SOURCE_ROW_NUMBER":"1837288","SMP_TAKEN_DT":"10/14/2026","CONC":".37","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-14"},{"SOURCE_ROW_NUMBER":"1751414","SMP_TAKEN_DT":"10/14/2026","CONC":".644","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"Miner is not active with QnC","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-14"},{"SOURCE_ROW_NUMBER":"2947137","SMP_TAKEN_DT":"10/13/2026","CONC":".441","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-13"},{"SOURCE_ROW_NUMBER":"2861823","SMP_TAKEN_DT":"10/13/2026","CONC":".762","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-13"},{"SOURCE_ROW_NUMBER":"2605405","SMP_TAKEN_DT":"10/13/2026","CONC":".066","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-13"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":263,"firstDate":"2005-06-23","lastDate":"2026-06-02","metrics":{"linkedIssuances":263},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":2466,"firstDate":"2005-03-14","lastDate":"2026-07-29","metrics":{"decisions":2310,"ssChanged":525,"recentRows":938,"decisionPenalty":2969057,"proposedPenalty":5322235},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"451880","CITATION_NO":"5132856","CITATION_ISSUE_DT":"07/29/2026","DOCKET_NO":"WEVA 2026-0397","CFR_STANDARD_CODE":"75.604(b)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1679.00","sourceDate":"2026-07-29"},{"SOURCE_ROW_NUMBER":"452195","CITATION_NO":"5132852","CITATION_ISSUE_DT":"07/28/2026","DOCKET_NO":"WEVA 2026-0397","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2133.00","sourceDate":"2026-07-28"},{"SOURCE_ROW_NUMBER":"112335","CITATION_NO":"5133472","CITATION_ISSUE_DT":"07/28/2026","DOCKET_NO":"WEVA 2026-0397","CFR_STANDARD_CODE":"75.807","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"755.00","sourceDate":"2026-07-28"},{"SOURCE_ROW_NUMBER":"56066","CITATION_NO":"5133474","CITATION_ISSUE_DT":"07/28/2026","DOCKET_NO":"WEVA 2026-0397","CFR_STANDARD_CODE":"75.1725(a)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1679.00","sourceDate":"2026-07-28"},{"SOURCE_ROW_NUMBER":"281852","CITATION_NO":"5133471","CITATION_ISSUE_DT":"07/27/2026","DOCKET_NO":"WEVA 2026-0397","CFR_STANDARD_CODE":"77.400(a)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1679.00","sourceDate":"2026-07-27"},{"SOURCE_ROW_NUMBER":"168709","CITATION_NO":"5132843","CITATION_ISSUE_DT":"07/22/2026","DOCKET_NO":"WEVA 2026-0397","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1550.00","sourceDate":"2026-07-22"},{"SOURCE_ROW_NUMBER":"225030","CITATION_NO":"5133467","CITATION_ISSUE_DT":"07/21/2026","DOCKET_NO":"WEVA 2026-0397","CFR_STANDARD_CODE":"77.512","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1679.00","sourceDate":"2026-07-21"},{"SOURCE_ROW_NUMBER":"394932","CITATION_NO":"5133465","CITATION_ISSUE_DT":"07/20/2026","DOCKET_NO":"WEVA 2026-0397","CFR_STANDARD_CODE":"75.514","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"755.00","sourceDate":"2026-07-20"},{"SOURCE_ROW_NUMBER":"55905","CITATION_NO":"5133463","CITATION_ISSUE_DT":"07/20/2026","DOCKET_NO":"WEVA 2026-0397","CFR_STANDARD_CODE":"75.1725(a)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1126.00","sourceDate":"2026-07-20"},{"SOURCE_ROW_NUMBER":"281851","CITATION_NO":"5133462","CITATION_ISSUE_DT":"07/19/2026","DOCKET_NO":"WEVA 2026-0397","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1037.00","sourceDate":"2026-07-19"},{"SOURCE_ROW_NUMBER":"224044","CITATION_NO":"5133460","CITATION_ISSUE_DT":"07/19/2026","DOCKET_NO":"WEVA 2026-0397","CFR_STANDARD_CODE":"75.1403","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1818.00","sourceDate":"2026-07-19"},{"SOURCE_ROW_NUMBER":"168853","CITATION_NO":"5133461","CITATION_ISSUE_DT":"07/19/2026","DOCKET_NO":"WEVA 2026-0397","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1219.00","sourceDate":"2026-07-19"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":4896,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":23,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":955,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":23,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"2004-03-25","lastDate":"2004-03-25","metrics":{"recentRows":0,"currentOperatorTenures":3,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":1843,"firstDate":"2004-08-30","lastDate":"2026-10-13","metrics":{"inspectors":2931,"recentRows":525,"onSiteHours":50915.5,"inspectionHours":76992.25,"inspectionSamples":5660},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"523140","EVENT_NO":"F005E96","INSPECTION_BEGIN_DT":"10/13/2026","INSPECTION_END_DT":"10/13/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.5","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2026-10-13"},{"SOURCE_ROW_NUMBER":"639955","EVENT_NO":"F005E95","INSPECTION_BEGIN_DT":"10/08/2026","INSPECTION_END_DT":"10/08/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"926184","EVENT_NO":"F005E93","INSPECTION_BEGIN_DT":"10/05/2026","INSPECTION_END_DT":"10/05/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"151836","EVENT_NO":"F01518F","INSPECTION_BEGIN_DT":"10/01/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"82.75","SUM_TOTAL_ON_SITE_HOURS":"58.5","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"873024","EVENT_NO":"F02EE0F","INSPECTION_BEGIN_DT":"09/29/2026","INSPECTION_END_DT":"09/29/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.25","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2026-09-29"},{"SOURCE_ROW_NUMBER":"838492","EVENT_NO":"F022447","INSPECTION_BEGIN_DT":"09/24/2026","INSPECTION_END_DT":"09/24/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"8.5","sourceDate":"2026-09-24"},{"SOURCE_ROW_NUMBER":"148127","EVENT_NO":"F02EE0E","INSPECTION_BEGIN_DT":"09/21/2026","INSPECTION_END_DT":"09/21/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2026-09-21"},{"SOURCE_ROW_NUMBER":"32059","EVENT_NO":"F02F688","INSPECTION_BEGIN_DT":"09/14/2026","INSPECTION_END_DT":"09/14/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2026-09-14"},{"SOURCE_ROW_NUMBER":"1142914","EVENT_NO":"F02F687","INSPECTION_BEGIN_DT":"09/08/2026","INSPECTION_END_DT":"09/08/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2026-09-08"},{"SOURCE_ROW_NUMBER":"259201","EVENT_NO":"F022446","INSPECTION_BEGIN_DT":"09/03/2026","INSPECTION_END_DT":"09/03/2026","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"11.5","SUM_TOTAL_ON_SITE_HOURS":"9.25","sourceDate":"2026-09-03"},{"SOURCE_ROW_NUMBER":"117580","EVENT_NO":"F02D872","INSPECTION_BEGIN_DT":"09/03/2026","INSPECTION_END_DT":"09/04/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-09-03"},{"SOURCE_ROW_NUMBER":"1006458","EVENT_NO":"F008575","INSPECTION_BEGIN_DT":"08/31/2026","INSPECTION_END_DT":"08/31/2026","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"15.5","SUM_TOTAL_ON_SITE_HOURS":"9.75","sourceDate":"2026-08-31"}]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":67,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017":{"hours":707155,"employees":279,"production":1509675},"2018":{"hours":787678,"employees":311,"production":1763202},"2019":{"hours":763798,"employees":305,"production":1256784},"2020":{"hours":709263,"employees":293,"production":891573},"2021":{"hours":703244,"employees":305,"production":866524},"2022":{"hours":731923,"employees":307,"production":749643},"2023":{"hours":755030,"employees":305,"production":1034656},"2024":{"hours":828735,"employees":349,"production":1102478},"2025":{"hours":790495,"employees":346,"production":1230323},"2026":{"hours":383172,"employees":318,"production":580765}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":678,"firstDate":"2006-04-26","lastDate":"2026-09-15","metrics":{"recentRows":203,"doseOver100":132,"actDoseTotal":61029,"pelDoseTotal":49770},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"252294","EVENT_NO":"F022443","SURVEY_DATE":"09/15/2026","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"40","ACT_DOSE_85":"51","PEL_DOSE_90":"88","SURVEY_TYPE":"I","sourceDate":"2026-09-15"},{"SOURCE_ROW_NUMBER":"252293","EVENT_NO":"F022443","SURVEY_DATE":"09/15/2026","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"54","PEL_DOSE_90":"72","SURVEY_TYPE":"I","sourceDate":"2026-09-15"},{"SOURCE_ROW_NUMBER":"252292","EVENT_NO":"F022443","SURVEY_DATE":"09/15/2026","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"65","PEL_DOSE_90":"42","SURVEY_TYPE":"I","sourceDate":"2026-09-15"},{"SOURCE_ROW_NUMBER":"252291","EVENT_NO":"F022443","SURVEY_DATE":"09/15/2026","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"52","PEL_DOSE_90":"25","SURVEY_TYPE":"I","sourceDate":"2026-09-15"},{"SOURCE_ROW_NUMBER":"252290","EVENT_NO":"F022443","SURVEY_DATE":"09/15/2026","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"62","PEL_DOSE_90":"89","SURVEY_TYPE":"I","sourceDate":"2026-09-15"},{"SOURCE_ROW_NUMBER":"252269","EVENT_NO":"F022440","SURVEY_DATE":"05/19/2026","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","ACT_DOSE_85":"18","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2026-05-19"},{"SOURCE_ROW_NUMBER":"252268","EVENT_NO":"F022440","SURVEY_DATE":"05/19/2026","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"25","ACT_DOSE_85":"20","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2026-05-19"},{"SOURCE_ROW_NUMBER":"252267","EVENT_NO":"F022440","SURVEY_DATE":"05/19/2026","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"25","ACT_DOSE_85":"18","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2026-05-19"},{"SOURCE_ROW_NUMBER":"252266","EVENT_NO":"F022440","SURVEY_DATE":"05/19/2026","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"40","ACT_DOSE_85":"84","PEL_DOSE_90":"85","SURVEY_TYPE":"I","sourceDate":"2026-05-19"},{"SOURCE_ROW_NUMBER":"252265","EVENT_NO":"F022440","SURVEY_DATE":"05/19/2026","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","ACT_DOSE_85":"42","PEL_DOSE_90":"31","SURVEY_TYPE":"I","sourceDate":"2026-05-19"},{"SOURCE_ROW_NUMBER":"252264","EVENT_NO":"F022440","SURVEY_DATE":"05/19/2026","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","ACT_DOSE_85":"34","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2026-05-19"},{"SOURCE_ROW_NUMBER":"252253","EVENT_NO":"F022440","SURVEY_DATE":"05/19/2026","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","ACT_DOSE_85":"19","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2026-05-19"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":725,"firstDate":"2006-04-12","lastDate":"2026-09-01","metrics":{"recentRows":365,"voidSamples":45,"maxQuartzPct":32.5,"validSamples":680,"quartzPctTotal":3930.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"156312","CASSETTE_NO":"58595890","SAMPLE_DT":"09/01/2026","QUARTZ_PCT":"03.9","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"153651","CASSETTE_NO":"58595851","SAMPLE_DT":"09/01/2026","QUARTZ_PCT":"06.5","QUARTZ_MICROGRAMS":"20","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"128998","CASSETTE_NO":"58596061","SAMPLE_DT":"09/01/2026","QUARTZ_PCT":"05.1","QUARTZ_MICROGRAMS":"10","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"116288","CASSETTE_NO":"58595972","SAMPLE_DT":"09/01/2026","QUARTZ_PCT":"05.8","QUARTZ_MICROGRAMS":"10","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"113905","CASSETTE_NO":"58595885","SAMPLE_DT":"09/01/2026","QUARTZ_PCT":"03.3","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"MMU NOT IN PRODUCING STATUS","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"98739","CASSETTE_NO":"58595668","SAMPLE_DT":"09/01/2026","QUARTZ_PCT":"06.6","QUARTZ_MICROGRAMS":"10","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"74908","CASSETTE_NO":"58595802","SAMPLE_DT":"09/01/2026","QUARTZ_PCT":"09.0","QUARTZ_MICROGRAMS":"14","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"MMU NOT IN PRODUCING STATUS","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"74182","CASSETTE_NO":"58595877","SAMPLE_DT":"09/01/2026","QUARTZ_PCT":"04.8","QUARTZ_MICROGRAMS":"14","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"71587","CASSETTE_NO":"58595804","SAMPLE_DT":"09/01/2026","QUARTZ_PCT":"07.9","QUARTZ_MICROGRAMS":"15","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"52750","CASSETTE_NO":"58595982","SAMPLE_DT":"09/01/2026","QUARTZ_MICROGRAMS":"0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"INTAKE AIR","VOID_CD_DESC":"INVALID SAMPLE TYPE","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"46222","CASSETTE_NO":"58596047","SAMPLE_DT":"09/01/2026","QUARTZ_PCT":"01.9","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"INTAKE AIR","VOID_CD_DESC":"INVALID SAMPLE TYPE","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"38062","CASSETTE_NO":"58595753","SAMPLE_DT":"09/01/2026","QUARTZ_PCT":"05.6","QUARTZ_MICROGRAMS":"10","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-01"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":7378,"firstDate":"2004-11-30","lastDate":"2026-10-14","metrics":{"ss":1563,"amountDue":5357619,"contested":280,"amountPaid":4547248,"recentRows":2361,"section104d":33,"unterminated":17,"proposedPenalty":6862922.1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2857498","VIOLATION_NO":"5098943","VIOLATION_ISSUE_DT":"10/14/2026","SIG_SUB":"N","PART_SECTION":"75.1731(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/14/2026","CONTESTED_IND":"N","sourceDate":"2026-10-14"},{"SOURCE_ROW_NUMBER":"2857497","VIOLATION_NO":"5098942","VIOLATION_ISSUE_DT":"10/14/2026","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","CONTESTED_IND":"N","sourceDate":"2026-10-14"},{"SOURCE_ROW_NUMBER":"2858024","VIOLATION_NO":"5097342","VIOLATION_ISSUE_DT":"10/13/2026","SIG_SUB":"N","PART_SECTION":"75.601-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/13/2026","CONTESTED_IND":"N","sourceDate":"2026-10-13"},{"SOURCE_ROW_NUMBER":"2857496","VIOLATION_NO":"5098941","VIOLATION_ISSUE_DT":"10/13/2026","SIG_SUB":"N","PART_SECTION":"75.1106-3(a)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/13/2026","CONTESTED_IND":"N","sourceDate":"2026-10-13"},{"SOURCE_ROW_NUMBER":"2857495","VIOLATION_NO":"5098940","VIOLATION_ISSUE_DT":"10/13/2026","SIG_SUB":"N","PART_SECTION":"75.604(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/13/2026","CONTESTED_IND":"N","sourceDate":"2026-10-13"},{"SOURCE_ROW_NUMBER":"2857494","VIOLATION_NO":"5098939","VIOLATION_ISSUE_DT":"10/13/2026","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/13/2026","CONTESTED_IND":"N","sourceDate":"2026-10-13"},{"SOURCE_ROW_NUMBER":"2857508","VIOLATION_NO":"5184234","VIOLATION_ISSUE_DT":"10/08/2026","SIG_SUB":"N","PART_SECTION":"75.1505(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/08/2026","CONTESTED_IND":"N","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2857507","VIOLATION_NO":"5184233","VIOLATION_ISSUE_DT":"10/08/2026","SIG_SUB":"N","PART_SECTION":"75.351(c)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/08/2026","CONTESTED_IND":"N","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2857506","VIOLATION_NO":"5184232","VIOLATION_ISSUE_DT":"10/08/2026","SIG_SUB":"N","PART_SECTION":"75.1600-2(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/08/2026","CONTESTED_IND":"N","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2857505","VIOLATION_NO":"5184231","VIOLATION_ISSUE_DT":"10/08/2026","SIG_SUB":"N","PART_SECTION":"75.1002(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/08/2026","CONTESTED_IND":"N","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2857504","VIOLATION_NO":"5184230","VIOLATION_ISSUE_DT":"10/08/2026","SIG_SUB":"N","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/08/2026","CONTESTED_IND":"N","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2857493","VIOLATION_NO":"5098938","VIOLATION_ISSUE_DT":"10/08/2026","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/08/2026","CONTESTED_IND":"N","sourceDate":"2026-10-08"}]}],"safety":{"href":"/api/v1/mines/4609029/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609029/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":{"averageEmployees":349,"companyType":"Operating Subsidiary","components":[{"averageEmployees":349,"laborHours":828735,"mineType":"Underground","productionTons":1102478}],"county":"Logan","laborHours":828735,"mineName":"Mountaineer Ii Mine","mineType":"Underground","mshaId":"4609029","operatingAddress":"P.O. Box E, Sharples, WV 25183","operatingCompany":"Mingo Logan Coal Llc","operationType":"Mine only","productionTons":1102478,"reportedRows":1,"sourceUrl":"https://www.eia.gov/coal/data/public/xls/coalpublic2024.xlsx","state":"West Virginia (Southern)","status":"Active","supplyRegion":"Appalachia Central","union":"","year":2024},"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1731","heading":"Maintenance of belt conveyors and belt conveyor entries.","id":"75.1731","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1731","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Damaged rollers, or other damaged belt conveyor components, which pose a fire hazard must be immediately repaired or replaced. All other damaged rollers, or other damaged belt conveyor components, must be repaired or replaced.\n\n(b) Conveyor belts must be properly aligned to prevent the moving belt from rubbing against the structure or components.\n\n(c) Materials shall not be allowed in the belt conveyor entry where the material may contribute to a frictional heating hazard.\n\n(d) Splicing of any approved conveyor belt must maintain flame-resistant properties of the belt.\n\n[73 FR 80616, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.601-1","heading":"Short circuit protection; ratings and settings of circuit breakers.","id":"75.601-1","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.601-1","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"Circuit breakers providing short circuit protection for trailing cables shall be set so as not to exceed the maximum allowable instantaneous settings specified in this section; however, higher settings may be permitted by an authorized representative of the Secretary when he has determined that special applications are justified:\n\nConductor size AWG or MGM Maximum allowable circuit breaker instantaneous setting (amperes) 14 50 12 75 10 150 8 200 6 300 4 500 3 600 2 800 1 1,000 1/0 1,250 2/0 1,500 3/0 2,000 4/0 2,500 250 2,500 300 2,500 350 2,500 400 2,500 450 2,500 500 2,500","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1106-3","heading":"Storage of liquefied and nonliquefied compressed gas cylinders; requirements.","id":"75.1106-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1106-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Liquefied and nonliquefied compressed gas cylinders stored in an underground coal mine shall be:\n\n(1) Clearly marked and identified as to their contents in accordance with Department of Transportation regulations.\n\n(2) Placed securely in storage areas designated by the operator for such purpose, and where the height of the coalbed permits, in an upright position, preferably in specially designated racks, or otherwise secured against being accidently tipped over.\n\n(3) Protected against damage from falling material, contact with power lines and energized electrical equipment, heat from welding, cutting or soldering, and exposure to flammable liquids.\n\n(b) Liquefied and nonliquefied compressed gas cylinders shall not be stored or left unattended in any area inby the last open crosscut of an underground coal mine.\n\n(c) When not in use, the valves of all liquefied and nonliquefied compressed gas cylinders shall be in the closed position, and all hoses shall be removed from the cylinder.\n\n[36 FR 22061, Nov. 19, 1971]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.604","heading":"Permanent splicing of trailing cables.","id":"75.604","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.604","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"[Statutory Provisions]\n\nWhen permanent splices in trailing cables are made, they shall be:\n\n(a) Mechanically strong with adequate electrical conductivity and flexibility;\n\n(b) Effectively insulated and sealed so as to exclude moisture; and\n\n(c) Vulcanized or otherwise treated with suitable materials to provide flame-resistant qualities and good bonding to the outer jacket.\n\n(d) Made using splice kits accepted or approved by MSHA as flame resistant.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 57 FR 61223, Dec. 23, 1992]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1505","heading":"Escapeway maps.","id":"75.1505","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-P/section-75.1505","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"P","subpartHeading":"Subpart P—Mine Emergencies","text":"(a) Content and accessibility. An escapeway map shall show the designated escapeways from the working sections or the miners' work stations to the surface or the exits at the bottom of the shaft or slope, refuge alternatives, and SCSR storage locations. The escapeway map shall be posted or readily accessible for all miners—\n\n(1) In each working section;\n\n(2) In each area where mechanized mining equipment is being installed or removed;\n\n(3) At the refuge alternative; and\n\n(4) At a surface location of the mine where miners congregate, such as at the mine bulletin board, bathhouse, or waiting room.\n\n(b) Keeping maps current. All maps shall be kept up-to-date and any change in route of travel, location of doors, location of refuge alternatives, or direction of airflow shall be shown on the maps by the end of the shift on which the change is made.\n\n(c) Informing affected miners. Miners underground on a shift when any such change is made shall be notified immediately of the change and other affected miners shall be informed of the change before entering the underground areas of the mine.\n\n[71 FR 71452, Dec. 8, 2006, as amended at 73 FR 80698, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.351","heading":"Atmospheric monitoring systems.","id":"75.351","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.351","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) AMS operation. Whenever personnel are underground and an AMS is used to fulfill the requirements of §§ 75.323(d)(1)(ii), 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), 75.350(d), or 75.362(f), the AMS must be operating and a designated AMS operator must be on duty at a location on the surface of the mine where audible and visual signals from the AMS must be seen or heard and the AMS operator can promptly respond to these signals.\n\n(b) Designated surface location and AMS operator. When an AMS is used to comply with §§ 75.323(d)(1)(ii), 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), 75.350(d), or 75.362(f), the following requirements apply:\n\n(1) The mine operator must designate a surface location at the mine where signals from the AMS will be received and two-way voice communication is maintained with each working section, with areas where mechanized mining equipment is being installed or removed, and with other areas designated in the approved emergency evacuation and firefighting program of instruction (§ 75.1502).\n\n(2) The mine operator must designate an AMS operator to monitor and promptly respond to all AMS signals. The AMS operator must have as a primary duty the responsibility to monitor the malfunction, alert and alarm signals of the AMS, and to notify appropriate personnel of these signals. In the event of an emergency, the sole responsibility of the AMS operator shall be to respond to the emergency.\n\n(3) A map or schematic must be provided at the designated surface location that shows the locations and type of AMS sensor at each location, and the intended air flow direction at these locations. This map or schematic must be updated within 24 hours of any change in this information.\n\n(4) The names of the designated AMS operators and other appropriate personnel, including the designated person responsible for initiating an emergency mine evacuation under § 75.1501, and the method to contact these persons, must be provided at the designated surface location.\n\n(c) Minimum operating requirements. AMSs used to comply with §§ 75.323(d)(1)(ii), 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), 75.350(d), or 75.362(f) must:\n\n(1) Automatically provide visual and audible signals at the designated surface location for any interruption of circuit continuity and any electrical malfunction of the system. These signals must be of sufficient magnitude to be seen or heard by the AMS operator.\n\n(2) Automatically provide visual and audible signals at the designated surface location when the carbon monoxide concentration or methane concentration at any sensor reaches the alert level as specified in § 75.351(i). These signals must be of sufficient magnitude to be seen or heard by the AMS operator.\n\n(3) Automatically provide visual and audible signals at the designated surface location distinguishable from alert signals when the carbon monoxide, smoke, or methane concentration at any sensor reaches the alarm level as specified in § 75.351(i). These signals must be of sufficient magnitude to be seen or heard by the AMS operator.\n\n(4) Automatically provide visual and audible signals at all affected working sections and at all affected areas where mechanized mining equipment is being installed or removed when the carbon monoxide, smoke, or methane concentration at any sensor reaches the alarm level as specified in § 75.351(i). These signals must be of sufficient magnitude to be seen or heard by miners working at these locations. Methane signals must be distinguishable from other signals.\n\n(5) Automatically provide visual and audible signals at other locations as specified in Mine Emergency Evacuation and Firefighting Program of Instruction (§ 75.1502) when the carbon monoxide, smoke, or methane concentration at any sensor reaches the alarm level as specified in § 75.351(i). These signals must be seen or heard by miners working at these locations. Methane alarms must be distinguishable from other signals.\n\n(6) Identify at the designated surface location the operational status of all sensors.\n\n(7) Automatically provide visual and audible alarm signals at the designated surface location, at all affected working sections, and at all affected areas where mechanized mining equipment is being installed or removed when the carbon monoxide level at any two consecutive sensors alert at the same time. These signals must be seen or heard by the AMS operator and miners working at these locations.\n\n(d) Location and installation of AMS sensors. (1) All AMS sensors, as specified in §§ 75.351(e) through 75.351(h), must be located such that measurements are representative of the mine atmosphere in these locations.\n\n(2) Carbon monoxide or smoke sensors must be installed near the center in the upper third of the entry, in a location that does not expose personnel working on the system to unsafe conditions. Sensors must not be located in abnormally high areas or in other locations where air flow patterns do not permit products of combustion to be carried to the sensors.\n\n(3) Methane sensors must be installed near the center of the entry, at least 12 inches from the roof, ribs, and floor, in a location that would not expose personnel working on the system to unsafe conditions.\n\n(e) Location of sensors-belt air course. (1) In addition to the requirements of paragraph (d) of this section, any AMS used to monitor belt air courses under § 75.350(b) must have approved sensors to monitor for carbon monoxide at the following locations:\n\n(i) At or near the working section belt tailpiece in the air stream ventilating the belt entry. In longwall mining systems the sensor must be located upwind in the belt entry at a distance no greater than 150 feet from the mixing point where intake air is mixed with the belt air at or near the tailpiece;\n\n(ii) No more than 50 feet upwind from the point where the belt air course is combined with another air course or splits into multiple air courses;\n\n(iii) At intervals not to exceed 1,000 feet along each belt entry. However, in areas along each belt entry where air velocities are between 50 and 100 feet per minute, spacing of sensors must not exceed 500 feet. In areas along each belt entry where air velocities are less than 50 feet per minute, the sensor spacing must not exceed 350 feet;\n\n(iv) Not more than 100 feet downwind of each belt drive unit, each tailpiece, transfer point, and each belt take-up. If the belt drive, tailpiece, and/or take-up for a single transfer point are installed together in the same air course, and the distance between the units is less than 100 feet, they may be monitored with one sensor downwind of the last component. If the distance between the units exceeds 100 feet, additional sensors are required downwind of each belt drive unit, each tailpiece, transfer point, and each belt take-up; and\n\n(v) At other locations in any entry that is part of the belt air course as required and specified in the mine ventilation plan.\n\n(2) Smoke sensors must be installed to monitor the belt entry under § 75.350(b) at the following locations:\n\n(i) At or near the working section belt tailpiece in the air stream ventilating the belt entry. In longwall mining systems the sensor must be located upwind in the belt entry at a distance no greater than 150 feet from the mixing point where intake air is mixed with the belt air at or near the tailpiece;\n\n(ii) Not more than 100 feet downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up. If the belt drive, tailpiece, and/or take-up for a single transfer point are installed together in the same air course, and the distance between the units is less than 100 feet, they may be monitored with one sensor downwind of the last component. If the distance between the units exceeds 100 feet, additional sensors are required downwind of each belt drive unit, each tailpiece, transfer point, and each belt take-up; and\n\n(iii) At intervals not to exceed 3,000 feet along each belt entry.\n\n(iv) This provision shall be effective one year after the Secretary has determined that a smoke sensor is available to reliably detect fire in underground coal mines.\n\n(f) Locations of sensors—the primary escapeway. When used to monitor the primary escapeway under § 75.350(b)(4), carbon monoxide or smoke sensors must be located in the primary escapeway within 500 feet of the working section and areas where mechanized mining equipment is being installed or removed. In addition, another sensor must be located within 500 feet inby the beginning of the panel. The point-feed sensor required by § 75.350(d)(1) may be used as the sensor at the beginning of the panel if it is located within 500 feet inby the beginning of the panel.\n\n(g) Location of sensors—return air splits. (1) If used to monitor return air splits under § 75.362(f), a methane sensor must be installed in the return air split between the last working place, longwall or shortwall face ventilated by that air split, and the junction of the return air split with another air split, seal, or worked out area.\n\n(2) If used to monitor a return air split under § 75.323(d)(1)(ii), the methane sensors must be installed at the following locations:\n\n(i) In the return air course opposite the section loading point, or, if exhausting auxiliary fan(s) are used, in the return air course no closer than 300 feet downwind from the fan exhaust and at a point opposite or immediately outby the section loading point; and\n\n(ii) Immediately upwind from the location where the return air split meets another air split or immediately upwind of the location where an air split is used to ventilate seals or worked-out areas.\n\n(h) Location of sensors—electrical installations. When monitoring the intake air ventilating underground transformer stations, battery charging stations, substations, rectifiers, or water pumps under § 75.340(a)(1)(ii) or § 75.340(a)(2)(ii), at least one sensor must be installed to monitor the mine atmosphere for carbon monoxide or smoke, located downwind and not greater than 50 feet from the electrical installation being monitored.\n\n(i) Establishing alert and alarm levels. An AMS installed in accordance with the following paragraphs must initiate alert and alarm signals at the specified levels, as indicated:\n\n(1) For § 75.323(d)(1)(ii) alarm at 1.5% methane.\n\n(2) For §§ 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), and 75.350(d), alert at 5 ppm carbon monoxide above the ambient level and alarm at 10 ppm carbon monoxide above the ambient level when carbon monoxide sensors are used; and alarm at a smoke optical density of 0.022 per meter when smoke sensors are used. Reduced alert and alarm settings approved by the district manager may be required for carbon monoxide sensors identified in the mine ventilation plan, § 75.371(nn).\n\n(3) For § 75.362(f), alert at 1.0% methane and alarm at 1.5% methane.\n\n(j) Establishing carbon monoxide ambient levels. Carbon monoxide ambient levels and the means to determine these levels must be approved in the mine ventilation plan (§ 75.371(hh)) for monitors installed in accordance with §§ 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), and 75.350(d).\n\n(k) Installation and maintenance. An AMS installed in accordance with §§ 75.323(d)(1)(ii), 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), 75.350(d), or 75.362(f) must be installed and maintained by personnel trained in the installation and maintenance of the system. The system must be maintained in proper operating condition.\n\n(l) Sensors. Sensors used to monitor for carbon monoxide, methane, and smoke must be either of a type listed and installed in accordance with the recommendations of a nationally recognized testing laboratory approved by the Secretary; or these sensors must be of a type, and installed in a manner, approved by the Secretary.\n\n(m) Time delays. When a demonstrated need exists, time delays may be incorporated into the AMS. These time delays must only be used to account for non-fire related carbon monoxide alert and alarm sensor signals. These time delays are limited to no more than three minutes. The use and length of any time delays, or other techniques or methods which eliminate or reduce the need for time delays, must be specified and approved in the mine ventilation plan.\n\n(n) Examination, testing, and calibration. (1) At least once each shift when belts are operated as part of a production shift, sensors used to detect carbon monoxide or smoke in accordance with §§ 75.350(b), and 75.350(d), and alarms installed in accordance with § 75.350(b) must be visually examined.\n\n(2) At least once every seven days, alarms for AMS installed in accordance with §§ 75.350(b), and 75.350(d) must be functionally tested for proper operation.\n\n(3) At intervals not to exceed 31 days—\n\n(i) Each carbon monoxide sensor installed in accordance with §§ 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), or 75.350(d) must be calibrated in accordance with the manufacturer's calibration specifications. Calibration must be done with a known concentration of carbon monoxide in air sufficient to activate the alarm;\n\n(ii) Each smoke sensor installed in accordance with §§ 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), or 75.350(d) must be functionally tested in accordance with the manufacturer's calibration specifications;\n\n(iii) Each methane sensor installed in accordance with §§ 75.323(d)(1)(ii) or 75.362(f) must be calibrated in accordance with the manufacturer's calibration specifications. Calibration must be done with a known concentration of methane in air sufficient to activate an alarm.\n\n(iv) If the alert or alarm signals will be activated during calibration of sensors, the AMS operator must be notified prior to and upon completion of calibration. The AMS operator must notify miners on affected working sections, areas where mechanized mining equipment is being installed or removed, or other areas designated in the approved emergency evacuation and firefighting program of instruction (§ 75.1502) when calibration will activate alarms and when calibration is completed.\n\n(4) Gases used for the testing and calibration of AMS sensors must be traceable to the National Institute of Standards and Technology reference standard for the specific gas. When these reference standards are not available for a specific gas, calibration gases must be traceable to an analytical standard which is prepared using a method traceable to the National Institute of Standards and Technology. Calibration gases must be within ±2.0 percent of the indicated gas concentration.\n\n(o) Recordkeeping. (1) When an AMS is used to comply with §§ 75.323(d)(1)(ii), 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), 75.350(d), or 75.362(f), individuals designated by the operator must make the following records by the end of the shift in which the following event(s) occur:\n\n(i) If an alert or alarm signal occurs, a record of the date, time, location and type of sensor, and the cause for the activation.\n\n(ii) If an AMS malfunctions, a record of the date, the extent and cause of the malfunction, and the corrective action taken to return the system to proper operation.\n\n(iii) A record of the seven-day tests of alert and alarm signals; calibrations; and maintenance of the AMS must be made by the person(s) performing these actions.\n\n(2) The person entering the record must include their name, date, and signature in the record.\n\n(3) The records required by this section must be kept either in a secure book that is not susceptible to alteration, or electronically in a computer system that is secure and not susceptible to alteration. These records must be maintained separately from other records and identifiable by a title, such as the ‘AMS log.’\n\n(p) Retention period. Records must be retained for at least one year at a surface location at the mine and made available for inspection by miners and authorized representatives of the Secretary.\n\n(q) Training. (1) All AMS operators must be trained annually in the proper operation of the AMS. This training must include the following subjects:\n\n(i) Familiarity with underground mining systems;\n\n(ii) Basic atmospheric monitoring system requirements;\n\n(iii) The mine emergency evacuation and firefighting program of instruction;\n\n(iv) The mine ventilation system including planned air directions;\n\n(v) Appropriate response to alert, alarm and malfunction signals;\n\n(vi) Use of mine communication systems including emergency notification procedures; and\n\n(vii) AMS recordkeeping requirements.\n\n(2) At least once every six months, all AMS operators must travel to all working sections.\n\n(3) A record of the content of training, the person conducting the training, and the date the training was conducted, must be maintained at the mine for at least one year by the mine operator.\n\n(r) Communications. When an AMS is used to comply with § 75.350(b), a two-way voice communication system required by § 75.1600 must be installed in an entry that is separate from the entry in which the AMS is installed no later than August 2, 2004. The two-way voice communication system may be installed in the entry where the intake sensors required by §§ 75.350(b)(4) or 75.350(d)(1) are installed.\n\n[69 FR 17527, Apr. 2, 2004, as amended at 73 FR 80612, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1600-2","heading":"Communication facilities; working sections; installation and maintenance requirements; audible or visual alarms.","id":"75.1600-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-Q/section-75.1600-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Communications","text":"(a) Telephones or equivalent two-way communication facilities provided at each working section shall be located not more than 500 feet outby the last open crosscut and not more than 800 feet from the farthest point of penetration of the working places on such section.\n\n(b) The incoming communication signal shall activate an audible alarm, distinguishable from the surrounding noise level, or a visual alarm that can be seen by a miner regularly employed on the working section.\n\n(c) If a communication system other than telephones is used and its operation depends entirely upon power from the mine electric system, means shall be provided to permit continued communication in the event the mine electric power fails or is cut off; provided, however, that where trolley phones and telephones are both used, an alternate source of power for the trolley phone system is not required.\n\n(d) Trolley phones connected to the trolley wire shall be grounded in accordance with Subpart H of this part.\n\n(e) Telephones or equivalent two-way communication facilities shall be maintained in good operating condition at all times. In the event of any failure in the system that results in loss of communication, repairs shall be started immediately, and the system restored to operating condition as soon as possible.\n\n[38 FR 29999, Oct. 31, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1002","heading":"Installation of electric equipment and conductors; permissibility.","id":"75.1002","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-K/section-75.1002","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"K","subpartHeading":"Subpart K—Trolley Wires and Trolley Feeder Wires","text":"(a) Electric equipment must be permissible and maintained in a permissible condition when such equipment is located within 150 feet of pillar workings or longwall faces.\n\n(b) Electric conductors and cables installed in or in by the last open crosscut or within 150 feet of pillar workings or longwall faces must be—\n\n(1) Shielded high-voltage cables supplying power to permissible longwall equipment;\n\n(2) Interconnecting conductors and cables of permissible longwall equipment;\n\n(3) Conductors and cables of intrinsically safe circuits; and\n\n(4) Cables and conductors supplying power to low- and medium-voltage permissible equipment.\n\n(5) Shielded high-voltage cables supplying power to permissible continuous mining machines.\n\n[67 FR 11004, Mar. 11, 2002, as amended at 75 FR 17553, Apr. 6, 2010]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609029","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}