{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4609017","name":"Mine No. 37","status":"Abandoned and Sealed","status_date":"2013-12-16","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Mcdowell","nearest_town":"Elbert","operator_id":"0050923","operator_name":"XMV, Inc.","controller_id":"M00106","controller_name":"Cleveland-Cliffs Inc","district":"C04","office":"Beckley District","employees":0,"latitude":37.348055,"longitude":-81.539444},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":2902},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609017","name":"Mine No. 37"},"operator":{"type":"operator","id":"0050923","name":"XMV, Inc."},"controller":{"type":"controller","id":"M00106","name":"Cleveland-Cliffs Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C16053","name":"Michelle  Hatfield"},"object":{"type":"mine","id":"4609017","name":"Mine No. 37"},"validFrom":"2002-09-17","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609017|C16053|2002-09-17|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00884","name":"William G  Skewes"},"object":{"type":"mine","id":"4609017","name":"Mine No. 37"},"validFrom":"2002-10-17","validTo":"2008-10-19","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609017|C00884|2002-10-17|2008-10-19"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0050923","name":"XMV, Inc."},"object":{"type":"mine","id":"4609017","name":"Mine No. 37"},"validFrom":"2003-12-29","validTo":"2004-01-21","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609017|0050923|2003-12-29|2004-01-21"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00884","name":"William G  Skewes"},"object":{"type":"operator","id":"0050923","name":"XMV, Inc."},"validFrom":"2003-12-29","validTo":"2004-01-21","current":false,"derived":true,"evidenceMineId":"4609017","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609017|0050923|2003-12-29|C00884|2002-10-17|50890"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24639","name":"Walcoal, Inc."},"object":{"type":"mine","id":"4609017","name":"Mine No. 37"},"validFrom":"2004-01-22","validTo":"2006-01-29","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609017|P24639|2004-01-22|2006-01-29"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C16053","name":"Michelle  Hatfield"},"object":{"type":"operator","id":"P24639","name":"Walcoal, Inc."},"validFrom":"2004-01-22","validTo":"2006-01-29","current":false,"derived":true,"evidenceMineId":"4609017","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609017|P24639|2004-01-22|C16053|2002-09-17|98192"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0050923","name":"XMV, Inc."},"object":{"type":"mine","id":"4609017","name":"Mine No. 37"},"validFrom":"2006-01-30","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609017|0050923|2006-01-30|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00884","name":"William G  Skewes"},"object":{"type":"operator","id":"0050923","name":"XMV, Inc."},"validFrom":"2006-01-30","validTo":"2008-10-19","current":false,"derived":true,"evidenceMineId":"4609017","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609017|0050923|2006-01-30|C00884|2002-10-17|50891"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0081113","name":"ArcelorMittal"},"object":{"type":"mine","id":"4609017","name":"Mine No. 37"},"validFrom":"2008-10-20","validTo":"2020-12-08","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609017|0081113|2008-10-20|2020-12-08"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0081113","name":"ArcelorMittal"},"object":{"type":"operator","id":"0050923","name":"XMV, Inc."},"validFrom":"2008-10-20","validTo":"2004-01-21","current":false,"derived":true,"evidenceMineId":"4609017","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609017|0050923|2003-12-29|0081113|2008-10-20|12894"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0081113","name":"ArcelorMittal"},"object":{"type":"operator","id":"0050923","name":"XMV, Inc."},"validFrom":"2008-10-20","validTo":"2020-12-08","current":false,"derived":true,"evidenceMineId":"4609017","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609017|0050923|2006-01-30|0081113|2008-10-20|12895"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"M00106","name":"Cleveland-Cliffs Inc"},"object":{"type":"mine","id":"4609017","name":"Mine No. 37"},"validFrom":"2020-12-09","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609017|M00106|2020-12-09|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"M00106","name":"Cleveland-Cliffs Inc"},"object":{"type":"operator","id":"0050923","name":"XMV, Inc."},"validFrom":"2020-12-09","validTo":"2004-01-21","current":false,"derived":true,"evidenceMineId":"4609017","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609017|0050923|2003-12-29|M00106|2020-12-09|104298"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"M00106","name":"Cleveland-Cliffs Inc"},"object":{"type":"operator","id":"0050923","name":"XMV, Inc."},"validFrom":"2020-12-09","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609017","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4609017|0050923|2006-01-30|M00106|2020-12-09|104299"}}],"coverage":{"historyRecords":7,"edgeCount":14,"intervalAnomalies":2,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":14,"firstDate":"2004-04-14","lastDate":"2013-06-15","metrics":{"daysLost":1090,"injuries":13,"fatalities":0,"recentRows":0,"restrictedDays":13,"contractorRecords":4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"98401","DOCUMENT_NO":"220131690016","ACCIDENT_DT":"06/15/2013","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Security guard, Watchman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"employee stepped into guard bldg to reach for 2 way radio setting in window, he tripped and as he fell, his left hand went through glass window","sourceDate":"2013-06-15"},{"SOURCE_ROW_NUMBER":"206101","DOCUMENT_NO":"220131710003","ACCIDENT_DT":"06/11/2013","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was helping with a belt move and a piece of belt structure fell and struck employee on hand.","sourceDate":"2013-06-11"},{"SOURCE_ROW_NUMBER":"201704","DOCUMENT_NO":"220092430062","ACCIDENT_DT":"08/24/2009","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall measuring approx. 3'x20'x40' occurred on the mains section-mmu 001-0","sourceDate":"2009-08-24"},{"SOURCE_ROW_NUMBER":"59738","DOCUMENT_NO":"220080020025","ACCIDENT_DT":"12/04/2007","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between running or meshing objects","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"130","NARRATIVE":"Employee was cleaning tail piece and put arm in tail roller and was injured.","sourceDate":"2007-12-04"},{"SOURCE_ROW_NUMBER":"98403","DOCUMENT_NO":"220070450025","ACCIDENT_DT":"01/29/2007","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"344","NARRATIVE":"The employee was in the process of moving timbers to start mining a lift. When he removed a timber near him, a piece of rock measuring approx. 7' x 3' x 18\" fell between bolts and struck the employee.","sourceDate":"2007-01-29"},{"SOURCE_ROW_NUMBER":"206100","DOCUMENT_NO":"220061770083","ACCIDENT_DT":"06/12/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"252","NARRATIVE":"While positioning the roof bolter to install roof bolts, a piece of draw rock fell and struck employee on upper back.","sourceDate":"2006-06-12"},{"SOURCE_ROW_NUMBER":"184615","DOCUMENT_NO":"220053640017","ACCIDENT_DT":"12/05/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"While installing last row bolt in #5 entry while drilling a piece of rock fell hitting the operator.","sourceDate":"2005-12-05"},{"SOURCE_ROW_NUMBER":"98402","DOCUMENT_NO":"220053420022","ACCIDENT_DT":"11/08/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"After installing outside pin moved to put inside pin up & a piece of rock fell between outside pin & ATRs.","sourceDate":"2005-11-08"},{"SOURCE_ROW_NUMBER":"154487","DOCUMENT_NO":"220051470064","ACCIDENT_DT":"05/04/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"60","NARRATIVE":"EE AND COWORKER WERE DRILLING HOLES IN MINE FLOOR TO ANCHOR THE TAILPIECE (HYDRAULIC DRILL - LOW COAL).  COWORKER TURNED HIS HANDLE LOOSE.  THE DRILL HIT EE ON THE RIGHT SIDE OF HIS HEAD.","sourceDate":"2005-05-04"},{"SOURCE_ROW_NUMBER":"89908","DOCUMENT_NO":"220051220031","ACCIDENT_DT":"04/20/2005","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"#1 HDG APP 50 TO 60' INBY INTERSECTION WHILE INSTALLING FIRST BOLT IN A CEW CUT A ROCK FELL FROM RIB OVER TO THE HEAD OF THE MACHINE WITH THE MACHINE CATCHING MOST OF THE WEIGHT EE WAS BENT DOWN DRILLING AND THE ROCK STRCUK EE IN AROUND SHOULDER AREA","sourceDate":"2005-04-20"},{"SOURCE_ROW_NUMBER":"180323","DOCUMENT_NO":"220050760049","ACCIDENT_DT":"03/04/2005","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Holding new bolt on belt line to run it down belt. belt stopped and ran backwards a few feet and twisted his back.","sourceDate":"2005-03-04"},{"SOURCE_ROW_NUMBER":"89907","DOCUMENT_NO":"220050600032","ACCIDENT_DT":"02/15/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"Loading oxygen tank in back of 3 wheeler ride and tank over balanced and put head in roof between roof and tank.","sourceDate":"2005-02-15"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2013-12-16","lastDate":"2013-12-16","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":486,"firstDate":"2004-03-25","lastDate":"2013-07-09","metrics":{"ss":149,"delinquent":473,"recentRows":0,"paidPenalty":355639,"proposedPenalty":607795,"currentAssessment":355639},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1845725","VIOLATION_NO":"7248053","ISSUE_DT":"07/09/2013","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"117.00","CURRENT_ASSESSMENT_AMT":"117.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-07-09"},{"SOURCE_ROW_NUMBER":"1845724","VIOLATION_NO":"7248052","ISSUE_DT":"07/09/2013","CFR_STANDARD_CD":"50.20(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-07-09"},{"SOURCE_ROW_NUMBER":"1846323","VIOLATION_NO":"7248051","ISSUE_DT":"06/25/2013","CFR_STANDARD_CD":"75.333(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"176.00","CURRENT_ASSESSMENT_AMT":"176.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-06-25"},{"SOURCE_ROW_NUMBER":"1846317","VIOLATION_NO":"7199587","ISSUE_DT":"06/25/2013","CFR_STANDARD_CD":"75.310(c)(4)(ii)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"460.00","CURRENT_ASSESSMENT_AMT":"460.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-06-25"},{"SOURCE_ROW_NUMBER":"1846316","VIOLATION_NO":"7199586","ISSUE_DT":"06/25/2013","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"308.00","CURRENT_ASSESSMENT_AMT":"308.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-06-25"},{"SOURCE_ROW_NUMBER":"1846315","VIOLATION_NO":"7199585","ISSUE_DT":"06/25/2013","CFR_STANDARD_CD":"75.1714-4(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"117.00","CURRENT_ASSESSMENT_AMT":"117.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-06-25"},{"SOURCE_ROW_NUMBER":"1846322","VIOLATION_NO":"7248050","ISSUE_DT":"06/19/2013","CFR_STANDARD_CD":"75.1731(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"460.00","CURRENT_ASSESSMENT_AMT":"460.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-06-19"},{"SOURCE_ROW_NUMBER":"1846321","VIOLATION_NO":"7248049","ISSUE_DT":"06/19/2013","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"334.00","CURRENT_ASSESSMENT_AMT":"334.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-06-19"},{"SOURCE_ROW_NUMBER":"1846320","VIOLATION_NO":"7248048","ISSUE_DT":"06/19/2013","CFR_STANDARD_CD":"75.1719-4(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"138.00","CURRENT_ASSESSMENT_AMT":"138.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-06-19"},{"SOURCE_ROW_NUMBER":"1846319","VIOLATION_NO":"7248047","ISSUE_DT":"06/19/2013","CFR_STANDARD_CD":"75.523-3(b)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"308.00","CURRENT_ASSESSMENT_AMT":"308.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-06-19"},{"SOURCE_ROW_NUMBER":"1846318","VIOLATION_NO":"7248046","ISSUE_DT":"06/13/2013","CFR_STANDARD_CD":"75.333(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"176.00","CURRENT_ASSESSMENT_AMT":"176.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-06-13"},{"SOURCE_ROW_NUMBER":"1848688","VIOLATION_NO":"7154151","ISSUE_DT":"03/27/2013","CFR_STANDARD_CD":"75.1103-4(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1026.00","CURRENT_ASSESSMENT_AMT":"726.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-03-27"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":235,"firstDate":"2008-11-19","lastDate":"2015-05-19","metrics":{"appeals":0,"decisions":235,"recentRows":0,"decisionPenalty":252725,"originalPenalty":547402},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"352635","VIOLATION_NO":"7178934","DOCKET_NO":"WEVA 2014-274","DECISION_DT":"05/19/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"687.00","DECISION_PENALTY_AMT":"687.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2015-05-19"},{"SOURCE_ROW_NUMBER":"351489","VIOLATION_NO":"7154146","DOCKET_NO":"WEVA 2014-274","DECISION_DT":"05/19/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1944.00","DECISION_PENALTY_AMT":"1379.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2015-05-19"},{"SOURCE_ROW_NUMBER":"102670","VIOLATION_NO":"7178938","DOCKET_NO":"WEVA 2014-274","DECISION_DT":"05/19/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2678.00","DECISION_PENALTY_AMT":"1893.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2015-05-19"},{"SOURCE_ROW_NUMBER":"102669","VIOLATION_NO":"7178935","DOCKET_NO":"WEVA 2014-274","DECISION_DT":"05/19/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"5961.00","DECISION_PENALTY_AMT":"4311.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2015-05-19"},{"SOURCE_ROW_NUMBER":"102668","VIOLATION_NO":"7162190","DOCKET_NO":"WEVA 2014-274","DECISION_DT":"05/19/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1203.00","DECISION_PENALTY_AMT":"1203.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2015-05-19"},{"SOURCE_ROW_NUMBER":"318848","VIOLATION_NO":"8146854","DOCKET_NO":"WEVA 2012-652","DECISION_DT":"04/02/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3405.00","DECISION_PENALTY_AMT":"764.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2015-04-02"},{"SOURCE_ROW_NUMBER":"318847","VIOLATION_NO":"8146842","DOCKET_NO":"WEVA 2012-652","DECISION_DT":"04/02/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"425.00","DECISION_PENALTY_AMT":"425.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2015-04-02"},{"SOURCE_ROW_NUMBER":"318435","VIOLATION_NO":"8146841","DOCKET_NO":"WEVA 2012-652","DECISION_DT":"04/02/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"425.00","DECISION_PENALTY_AMT":"112.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2015-04-02"},{"SOURCE_ROW_NUMBER":"318056","VIOLATION_NO":"8136419","DOCKET_NO":"WEVA 2012-652","DECISION_DT":"04/02/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"946.00","DECISION_PENALTY_AMT":"212.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2015-04-02"},{"SOURCE_ROW_NUMBER":"82728","VIOLATION_NO":"8136420","DOCKET_NO":"WEVA 2012-652","DECISION_DT":"04/02/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"425.00","DECISION_PENALTY_AMT":"425.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2015-04-02"},{"SOURCE_ROW_NUMBER":"82639","VIOLATION_NO":"8146853","DOCKET_NO":"WEVA 2012-652","DECISION_DT":"04/02/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2106.00","DECISION_PENALTY_AMT":"2106.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2015-04-02"},{"SOURCE_ROW_NUMBER":"108037","VIOLATION_NO":"7162189","DOCKET_NO":"WEVA 2014-1072","DECISION_DT":"01/07/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1795.00","DECISION_PENALTY_AMT":"1795.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2015-01-07"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":528,"firstDate":"2004-05-11","lastDate":"2013-08-19","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":45,"validSamples":483,"maxConcentration":7.035,"concentrationTotal":331.385},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1240701","CASS_NUM":"51235036","SMP_TAKEN_DT":"8/19/2013","CONC":".25","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-08-19"},{"SOURCE_ROW_NUMBER":"1078499","CASS_NUM":"51248438","SMP_TAKEN_DT":"8/16/2013","CONC":".201","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-08-16"},{"SOURCE_ROW_NUMBER":"286431","CASS_NUM":"51248823","SMP_TAKEN_DT":"8/15/2013","CONC":".077","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-08-15"},{"SOURCE_ROW_NUMBER":"314961","CASS_NUM":"51234769","SMP_TAKEN_DT":"8/14/2013","CONC":".228","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-08-14"},{"SOURCE_ROW_NUMBER":"110582","CASS_NUM":"51235094","SMP_TAKEN_DT":"8/13/2013","CONC":".543","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-08-13"},{"SOURCE_ROW_NUMBER":"1290332","CASS_NUM":"58013924","SMP_TAKEN_DT":"7/24/2013","CONC":".04","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-07-24"},{"SOURCE_ROW_NUMBER":"1285840","CASS_NUM":"58013817","SMP_TAKEN_DT":"7/24/2013","CONC":".11","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-07-24"},{"SOURCE_ROW_NUMBER":"996581","CASS_NUM":"58013729","SMP_TAKEN_DT":"7/24/2013","CONC":".408","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-07-24"},{"SOURCE_ROW_NUMBER":"938036","CASS_NUM":"58013851","SMP_TAKEN_DT":"7/24/2013","CONC":".54","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-07-24"},{"SOURCE_ROW_NUMBER":"635265","CASS_NUM":"58013806","SMP_TAKEN_DT":"7/24/2013","CONC":".089","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-07-24"},{"SOURCE_ROW_NUMBER":"518477","CASS_NUM":"58013747","SMP_TAKEN_DT":"7/24/2013","CONC":".406","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-07-24"},{"SOURCE_ROW_NUMBER":"174118","CASS_NUM":"58013848","SMP_TAKEN_DT":"7/24/2013","CONC":".529","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER HELPER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-07-24"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":36,"firstDate":"2008-02-25","lastDate":"2013-10-30","metrics":{"linkedIssuances":36},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":235,"firstDate":"2007-01-29","lastDate":"2013-03-27","metrics":{"decisions":235,"ssChanged":49,"recentRows":0,"decisionPenalty":252725,"proposedPenalty":547402},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"31704","CITATION_NO":"7154151","CITATION_ISSUE_DT":"03/27/2013","DOCKET_NO":"WEVA 2013-949","DECISION_DT":"01/06/2014","CFR_STANDARD_CODE":"75.1103-4(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1026.00","DECISION_PENALTY_AMT":"726.00","sourceDate":"2013-03-27"},{"SOURCE_ROW_NUMBER":"427855","CITATION_NO":"7162189","CITATION_ISSUE_DT":"03/26/2013","DOCKET_NO":"WEVA 2014-1072","DECISION_DT":"01/07/2015","CFR_STANDARD_CODE":"75.360(e)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1795.00","DECISION_PENALTY_AMT":"1795.00","sourceDate":"2013-03-26"},{"SOURCE_ROW_NUMBER":"317666","CITATION_NO":"7162190","CITATION_ISSUE_DT":"03/26/2013","DOCKET_NO":"WEVA 2014-274","DECISION_DT":"05/19/2015","CFR_STANDARD_CODE":"75.360(g)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1203.00","DECISION_PENALTY_AMT":"1203.00","sourceDate":"2013-03-26"},{"SOURCE_ROW_NUMBER":"35089","CITATION_NO":"7162188","CITATION_ISSUE_DT":"03/25/2013","DOCKET_NO":"WEVA 2013-949","DECISION_DT":"01/06/2014","CFR_STANDARD_CODE":"75.503","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"634.00","DECISION_PENALTY_AMT":"634.00","sourceDate":"2013-03-25"},{"SOURCE_ROW_NUMBER":"257684","CITATION_NO":"7162186","CITATION_ISSUE_DT":"03/22/2013","DOCKET_NO":"WEVA 2013-1265","DECISION_DT":"02/25/2014","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"807.00","DECISION_PENALTY_AMT":"807.00","sourceDate":"2013-03-22"},{"SOURCE_ROW_NUMBER":"374119","CITATION_NO":"7162185","CITATION_ISSUE_DT":"03/21/2013","DOCKET_NO":"WEVA 2013-949","DECISION_DT":"01/06/2014","CFR_STANDARD_CODE":"75.503","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"807.00","DECISION_PENALTY_AMT":"400.00","sourceDate":"2013-03-21"},{"SOURCE_ROW_NUMBER":"429505","CITATION_NO":"7178940","CITATION_ISSUE_DT":"03/20/2013","DOCKET_NO":"WEVA 2013-949","DECISION_DT":"01/06/2014","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"540.00","DECISION_PENALTY_AMT":"440.00","sourceDate":"2013-03-20"},{"SOURCE_ROW_NUMBER":"317667","CITATION_NO":"7178937","CITATION_ISSUE_DT":"03/20/2013","DOCKET_NO":"WEVA 2013-1265","DECISION_DT":"02/25/2014","CFR_STANDARD_CODE":"75.380(d)(7)(iv)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3405.00","DECISION_PENALTY_AMT":"2450.00","sourceDate":"2013-03-20"},{"SOURCE_ROW_NUMBER":"315981","CITATION_NO":"7248931","CITATION_ISSUE_DT":"03/20/2013","DOCKET_NO":"WEVA 2013-1265","DECISION_DT":"02/25/2014","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"2106.00","DECISION_PENALTY_AMT":"541.00","sourceDate":"2013-03-20"},{"SOURCE_ROW_NUMBER":"313649","CITATION_NO":"7178938","CITATION_ISSUE_DT":"03/20/2013","DOCKET_NO":"WEVA 2014-274","DECISION_DT":"05/19/2015","CFR_STANDARD_CODE":"75.1505(b)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"2678.00","DECISION_PENALTY_AMT":"1893.00","sourceDate":"2013-03-20"},{"SOURCE_ROW_NUMBER":"257073","CITATION_NO":"7178932","CITATION_ISSUE_DT":"03/20/2013","DOCKET_NO":"WEVA 2013-1265","DECISION_DT":"02/25/2014","CFR_STANDARD_CODE":"75.380(d)(7)(i)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2678.00","DECISION_PENALTY_AMT":"2678.00","sourceDate":"2013-03-20"},{"SOURCE_ROW_NUMBER":"256833","CITATION_NO":"7178935","CITATION_ISSUE_DT":"03/20/2013","DOCKET_NO":"WEVA 2014-274","DECISION_DT":"05/19/2015","CFR_STANDARD_CODE":"75.333(h)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"5961.00","DECISION_PENALTY_AMT":"4311.00","sourceDate":"2013-03-20"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":485,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":103,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":7,"firstDate":"2003-12-29","lastDate":"2006-01-30","metrics":{"recentRows":0,"currentOperatorTenures":3,"completedOperatorTenures":4},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":74,"firstDate":"2004-03-24","lastDate":"2013-12-16","metrics":{"inspectors":125,"recentRows":0,"onSiteHours":2154.5,"inspectionHours":3685,"inspectionSamples":542},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"504527","EVENT_NO":"6304204","INSPECTION_BEGIN_DT":"12/16/2013","INSPECTION_END_DT":"12/16/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2013-12-16"},{"SOURCE_ROW_NUMBER":"312459","EVENT_NO":"6301523","INSPECTION_BEGIN_DT":"09/05/2013","INSPECTION_END_DT":"09/05/2013","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2013-09-05"},{"SOURCE_ROW_NUMBER":"612926","EVENT_NO":"6301520","INSPECTION_BEGIN_DT":"08/14/2013","INSPECTION_END_DT":"08/14/2013","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2013-08-14"},{"SOURCE_ROW_NUMBER":"45360","EVENT_NO":"6299121","INSPECTION_BEGIN_DT":"07/24/2013","INSPECTION_END_DT":"08/22/2013","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14.5","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2013-07-24"},{"SOURCE_ROW_NUMBER":"969613","EVENT_NO":"6301515","INSPECTION_BEGIN_DT":"07/23/2013","INSPECTION_END_DT":"07/23/2013","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2013-07-23"},{"SOURCE_ROW_NUMBER":"32763","EVENT_NO":"6299117","INSPECTION_BEGIN_DT":"07/08/2013","INSPECTION_END_DT":"07/10/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"45.5","SUM_TOTAL_ON_SITE_HOURS":"21.5","sourceDate":"2013-07-08"},{"SOURCE_ROW_NUMBER":"806322","EVENT_NO":"6299410","INSPECTION_BEGIN_DT":"06/11/2013","INSPECTION_END_DT":"06/25/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"85.25","SUM_TOTAL_ON_SITE_HOURS":"55.75","sourceDate":"2013-06-11"},{"SOURCE_ROW_NUMBER":"594526","EVENT_NO":"6301505","INSPECTION_BEGIN_DT":"05/28/2013","INSPECTION_END_DT":"05/28/2013","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"5.25","sourceDate":"2013-05-28"},{"SOURCE_ROW_NUMBER":"543614","EVENT_NO":"6299867","INSPECTION_BEGIN_DT":"04/23/2013","INSPECTION_END_DT":"04/23/2013","ACTIVITY_CODE":"E19","ACTIVITY":"Electrical Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2013-04-23"},{"SOURCE_ROW_NUMBER":"741817","EVENT_NO":"6298349","INSPECTION_BEGIN_DT":"04/10/2013","INSPECTION_END_DT":"04/10/2013","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"6.25","sourceDate":"2013-04-10"},{"SOURCE_ROW_NUMBER":"1117008","EVENT_NO":"6297731","INSPECTION_BEGIN_DT":"04/04/2013","INSPECTION_END_DT":"04/04/2013","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.5","SUM_TOTAL_ON_SITE_HOURS":"4.25","sourceDate":"2013-04-04"},{"SOURCE_ROW_NUMBER":"1098579","EVENT_NO":"6299862","INSPECTION_BEGIN_DT":"03/19/2013","INSPECTION_END_DT":"03/27/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"9","SUM_TOTAL_INSP_HOURS":"171","SUM_TOTAL_ON_SITE_HOURS":"108.5","sourceDate":"2013-03-19"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":118,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2014-Q2":{"hours":0,"employees":0,"production":0},"2013-Q4":{"hours":2094,"employees":15,"production":1077},"2013-Q3":{"hours":8422,"employees":14,"production":10785},"2013-Q2":{"hours":9109,"employees":14,"production":14269},"2013-Q1":{"hours":10015,"employees":15,"production":17712},"2012-Q4":{"hours":8468,"employees":13,"production":14239},"2012-Q3":{"hours":8949,"employees":14,"production":2187},"2012-Q2":{"hours":9574,"employees":15,"production":10937},"2012-Q1":{"hours":9367,"employees":14,"production":9777},"2011-Q4":{"hours":9388,"employees":14,"production":12870},"2011-Q3":{"hours":11959,"employees":19,"production":10083},"2011-Q2":{"hours":21229,"employees":26,"production":29219}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":13,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2004":{"hours":22858,"employees":22,"production":1902},"2005":{"hours":50767,"employees":29,"production":76315},"2006":{"hours":48080,"employees":27,"production":71861},"2007":{"hours":42920,"employees":20,"production":78800},"2008":{"hours":63256,"employees":27,"production":158167},"2009":{"hours":82126,"employees":35,"production":125234},"2010":{"hours":95993,"employees":38,"production":163250},"2011":{"hours":67165,"employees":24,"production":87073},"2012":{"hours":36358,"employees":14,"production":37140},"2013":{"hours":29640,"employees":15,"production":43843}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":47,"firstDate":"2005-09-06","lastDate":"2013-07-24","metrics":{"recentRows":0,"doseOver100":4,"actDoseTotal":2182,"pelDoseTotal":1518},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"250428","EVENT_NO":"6299121","SURVEY_DATE":"07/24/2013","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"21","PEL_DOSE_90":"14","SURVEY_TYPE":"I","sourceDate":"2013-07-24"},{"SOURCE_ROW_NUMBER":"250427","EVENT_NO":"6299121","SURVEY_DATE":"07/24/2013","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"40","PEL_DOSE_90":"29","SURVEY_TYPE":"I","sourceDate":"2013-07-24"},{"SOURCE_ROW_NUMBER":"250426","EVENT_NO":"6299121","SURVEY_DATE":"07/24/2013","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"27","MANUFACTURER_CD":"058","ACT_DOSE_85":"46","PEL_DOSE_90":"27","SURVEY_TYPE":"I","sourceDate":"2013-07-24"},{"SOURCE_ROW_NUMBER":"250425","EVENT_NO":"6299121","SURVEY_DATE":"07/24/2013","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"40","PEL_DOSE_90":"32","SURVEY_TYPE":"I","sourceDate":"2013-07-24"},{"SOURCE_ROW_NUMBER":"250424","EVENT_NO":"6299121","SURVEY_DATE":"07/24/2013","OCCUPATION_CD_DESC":"CONTINUOUS MINER HELPER","MACHINE_CD":"06","MANUFACTURER_CD":"066","ACT_DOSE_85":"59","PEL_DOSE_90":"38","SURVEY_TYPE":"I","sourceDate":"2013-07-24"},{"SOURCE_ROW_NUMBER":"250423","EVENT_NO":"6299121","SURVEY_DATE":"07/24/2013","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"066","ACT_DOSE_85":"56","PEL_DOSE_90":"49","SURVEY_TYPE":"I","sourceDate":"2013-07-24"},{"SOURCE_ROW_NUMBER":"250422","EVENT_NO":"6293444","SURVEY_DATE":"12/12/2011","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"70","PEL_DOSE_90":"55","SURVEY_TYPE":"I","sourceDate":"2011-12-12"},{"SOURCE_ROW_NUMBER":"250421","EVENT_NO":"6293444","SURVEY_DATE":"12/12/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"50","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2011-12-12"},{"SOURCE_ROW_NUMBER":"250420","EVENT_NO":"6293444","SURVEY_DATE":"12/12/2011","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"066","ACT_DOSE_85":"24","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2011-12-12"},{"SOURCE_ROW_NUMBER":"250419","EVENT_NO":"6293444","SURVEY_DATE":"12/12/2011","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"30","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2011-12-12"},{"SOURCE_ROW_NUMBER":"250418","EVENT_NO":"6293426","SURVEY_DATE":"09/07/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"49","PEL_DOSE_90":"25","SURVEY_TYPE":"I","sourceDate":"2011-09-07"},{"SOURCE_ROW_NUMBER":"250417","EVENT_NO":"6293426","SURVEY_DATE":"09/07/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"46","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2011-09-07"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":22,"firstDate":"2004-05-24","lastDate":"2013-03-25","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":8.5,"validSamples":22,"quartzPctTotal":81.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"129659","CASSETTE_NO":"57999886","SAMPLE_DT":"03/25/2013","QUARTZ_PCT":"01.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-03-25"},{"SOURCE_ROW_NUMBER":"105137","CASSETTE_NO":"57989730","SAMPLE_DT":"12/19/2012","QUARTZ_PCT":"01.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-12-19"},{"SOURCE_ROW_NUMBER":"50665","CASSETTE_NO":"57945895","SAMPLE_DT":"06/05/2012","QUARTZ_PCT":"02.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-06-05"},{"SOURCE_ROW_NUMBER":"40249","CASSETTE_NO":"57967352","SAMPLE_DT":"03/15/2012","QUARTZ_PCT":"05.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-03-15"},{"SOURCE_ROW_NUMBER":"31558","CASSETTE_NO":"57901028","SAMPLE_DT":"12/12/2011","QUARTZ_PCT":"04.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-12-12"},{"SOURCE_ROW_NUMBER":"56254","CASSETTE_NO":"57885558","SAMPLE_DT":"09/07/2011","QUARTZ_PCT":"07.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-09-07"},{"SOURCE_ROW_NUMBER":"75244","CASSETTE_NO":"57885818","SAMPLE_DT":"06/09/2011","QUARTZ_PCT":"02.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-06-09"},{"SOURCE_ROW_NUMBER":"3845","CASSETTE_NO":"57853453","SAMPLE_DT":"03/02/2011","QUARTZ_PCT":"02.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-03-02"},{"SOURCE_ROW_NUMBER":"5927","CASSETTE_NO":"57821951","SAMPLE_DT":"01/13/2010","QUARTZ_PCT":"03.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-01-13"},{"SOURCE_ROW_NUMBER":"79143","CASSETTE_NO":"57728633","SAMPLE_DT":"05/12/2009","QUARTZ_PCT":"04.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-05-12"},{"SOURCE_ROW_NUMBER":"43979","CASSETTE_NO":"57683159","SAMPLE_DT":"02/02/2009","QUARTZ_PCT":"02.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-02-02"},{"SOURCE_ROW_NUMBER":"12828","CASSETTE_NO":"57743638","SAMPLE_DT":"07/16/2008","QUARTZ_PCT":"02.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-07-16"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":497,"firstDate":"2004-03-24","lastDate":"2013-07-09","metrics":{"ss":147,"amountDue":355639,"contested":127,"amountPaid":355639,"recentRows":0,"section104d":7,"unterminated":3,"proposedPenalty":607795},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2842498","VIOLATION_NO":"7248053","VIOLATION_ISSUE_DT":"07/09/2013","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/10/2013","PROPOSED_PENALTY":"117","AMOUNT_DUE":"117","AMOUNT_PAID":"117","CONTESTED_IND":"N","sourceDate":"2013-07-09"},{"SOURCE_ROW_NUMBER":"2842497","VIOLATION_NO":"7248052","VIOLATION_ISSUE_DT":"07/09/2013","SIG_SUB":"N","PART_SECTION":"50.20(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/09/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-07-09"},{"SOURCE_ROW_NUMBER":"2842490","VIOLATION_NO":"7248051","VIOLATION_ISSUE_DT":"06/25/2013","SIG_SUB":"N","PART_SECTION":"75.333(h)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/09/2013","PROPOSED_PENALTY":"176","AMOUNT_DUE":"176","AMOUNT_PAID":"176","CONTESTED_IND":"N","sourceDate":"2013-06-25"},{"SOURCE_ROW_NUMBER":"2842484","VIOLATION_NO":"7199587","VIOLATION_ISSUE_DT":"06/25/2013","SIG_SUB":"N","PART_SECTION":"75.310(c)(4)(ii)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"12","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/25/2013","PROPOSED_PENALTY":"460","AMOUNT_DUE":"460","AMOUNT_PAID":"460","CONTESTED_IND":"N","sourceDate":"2013-06-25"},{"SOURCE_ROW_NUMBER":"2842483","VIOLATION_NO":"7199586","VIOLATION_ISSUE_DT":"06/25/2013","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/25/2013","PROPOSED_PENALTY":"308","AMOUNT_DUE":"308","AMOUNT_PAID":"308","CONTESTED_IND":"N","sourceDate":"2013-06-25"},{"SOURCE_ROW_NUMBER":"2842482","VIOLATION_NO":"7199585","VIOLATION_ISSUE_DT":"06/25/2013","SIG_SUB":"N","PART_SECTION":"75.1714-4(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/25/2013","PROPOSED_PENALTY":"117","AMOUNT_DUE":"117","AMOUNT_PAID":"117","CONTESTED_IND":"N","sourceDate":"2013-06-25"},{"SOURCE_ROW_NUMBER":"2842489","VIOLATION_NO":"7248050","VIOLATION_ISSUE_DT":"06/19/2013","SIG_SUB":"N","PART_SECTION":"75.1731(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"06/25/2013","PROPOSED_PENALTY":"460","AMOUNT_DUE":"460","AMOUNT_PAID":"460","CONTESTED_IND":"N","sourceDate":"2013-06-19"},{"SOURCE_ROW_NUMBER":"2842488","VIOLATION_NO":"7248049","VIOLATION_ISSUE_DT":"06/19/2013","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/19/2013","PROPOSED_PENALTY":"334","AMOUNT_DUE":"334","AMOUNT_PAID":"334","CONTESTED_IND":"N","sourceDate":"2013-06-19"},{"SOURCE_ROW_NUMBER":"2842487","VIOLATION_NO":"7248048","VIOLATION_ISSUE_DT":"06/19/2013","SIG_SUB":"N","PART_SECTION":"75.1719-4(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/19/2013","PROPOSED_PENALTY":"138","AMOUNT_DUE":"138","AMOUNT_PAID":"138","CONTESTED_IND":"N","sourceDate":"2013-06-19"},{"SOURCE_ROW_NUMBER":"2842486","VIOLATION_NO":"7248047","VIOLATION_ISSUE_DT":"06/19/2013","SIG_SUB":"Y","PART_SECTION":"75.523-3(b)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/19/2013","PROPOSED_PENALTY":"308","AMOUNT_DUE":"308","AMOUNT_PAID":"308","CONTESTED_IND":"N","sourceDate":"2013-06-19"},{"SOURCE_ROW_NUMBER":"2842485","VIOLATION_NO":"7248046","VIOLATION_ISSUE_DT":"06/13/2013","SIG_SUB":"N","PART_SECTION":"75.333(h)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/09/2013","PROPOSED_PENALTY":"176","AMOUNT_DUE":"176","AMOUNT_PAID":"176","CONTESTED_IND":"N","sourceDate":"2013-06-13"},{"SOURCE_ROW_NUMBER":"2842331","VIOLATION_NO":"7154151","VIOLATION_ISSUE_DT":"03/27/2013","SIG_SUB":"Y","PART_SECTION":"75.1103-4(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/27/2013","PROPOSED_PENALTY":"1026","AMOUNT_DUE":"726","AMOUNT_PAID":"726","CONTESTED_IND":"N","sourceDate":"2013-03-27"}]}],"safety":{"href":"/api/v1/mines/4609017/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609017/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","heading":"Preparation and submission of MSHA Report Form 7000-1—Mine Accident, Injury, and Illness Report.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-I/part-50/subpart-C/section-50.20","part":"50","subchapter":"I","subpart":"C","id":"50.20","citation":"30 CFR 50.20","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER I—ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND PRODUCTION IN MINES","partHeading":"PART 50—NOTIFICATION, INVESTIGATION, REPORTS AND RECORDS OF ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND COAL PRODUCTION IN MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":2},{"chapter":"I","heading":"Installation of main mine fans.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.310","part":"75","subchapter":"O","subpart":"D","id":"75.310","citation":"30 CFR 75.310","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1714-4","heading":"Additional self-contained self-rescuers (SCSRs).","id":"75.1714-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Additional SCSRs in work places. In addition to the requirements in §§ 75.1714, 75.1714-1, 75.1714-2, and 75.1714-3 of this part, the mine operator shall provide the following:\n\n(1) At least one additional SCSR, which provides protection for a period of one hour or longer, for each person at a fixed underground work location.\n\n(2) Additional SCSRs along the normal travel routes for pumpers, examiners, and other persons who do not have a fixed work location to be stored at a distance an average miner could walk in 30 minutes. The SCSR storage locations shall be determined by using one of the methods found under paragraph (c)(2) of this section.\n\n(b) Additional SCSRs on mantrips. If a mantrip or mobile equipment is used to enter or exit the mine, at least one additional SCSR, which provides protection for a period of one hour or longer, shall be available for each person who uses such transportation from portal to portal.\n\n(c) Additional SCSRs in escapeways. When each person underground cannot safely evacuate the mine within 30 minutes, the mine operator shall provide additional SCSRs stored in each required escapeway.\n\n(1) Each storage location shall contain at least one SCSR, which provides protection for a period of one hour or longer, for every person who will be inby that location.\n\n(2) Storage locations shall be spaced along each escapeway at 30-minute travel distances no greater than the distances determined by—\n\n(i) Calculating the distance an average miner walks in 30 minutes by using the time necessary for each miner in a sample of typical miners to walk a typical length of each escapeway; or\n\n(ii) Using the SCSR storage location spacing specified in the following table, except for escapeways with grades over 5 percent.\n\nAverage entry height Maximum distancebetween SCSR storage locations (in ft.) <40 in. (Crawl) 2,200 >40-<50 in. (Duck Walk) 3,300 >50-<65 in. (Walk Head Bent) 4,400 >65 in. (Walk Erect) 5,700\n\n(d) Additional SCSRs in hardened rooms. As an alternative to providing SCSR storage locations in each escapeway, the mine operator may store SCSRs in a hardened room located between adjacent escapeways.\n\n(1) The hardened room shall be designed and constructed to the same explosion force criteria as seals.\n\n(2) The hardened room shall include a means to provide independent, positive pressure ventilation from the surface during an emergency.\n\n(3) The District Manager shall approve the design and construction of hardened rooms in the ventilation plan.\n\n(4) These SCSR storage locations shall be spaced in accordance with paragraph (c) of this section.\n\n(e) Storage location accessibility. All SCSRs required under this section shall be stored according to the manufacturers' instructions, in conspicuous locations readily accessible by each person in the mine.\n\n(f) Storage location signs. A sign made of reflective material with the words “SCSRs” or “SELF-RESCUERS” shall be conspicuously posted at each storage location. Direction signs made of a reflective material shall be posted leading to each storage location.\n\n[71 FR 71454, Dec. 8, 2006]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1731","heading":"Maintenance of belt conveyors and belt conveyor entries.","id":"75.1731","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1731","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Damaged rollers, or other damaged belt conveyor components, which pose a fire hazard must be immediately repaired or replaced. All other damaged rollers, or other damaged belt conveyor components, must be repaired or replaced.\n\n(b) Conveyor belts must be properly aligned to prevent the moving belt from rubbing against the structure or components.\n\n(c) Materials shall not be allowed in the belt conveyor entry where the material may contribute to a frictional heating hazard.\n\n(d) Splicing of any approved conveyor belt must maintain flame-resistant properties of the belt.\n\n[73 FR 80616, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","heading":"Mining machines, cap lamps; requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1719-4","part":"75","subchapter":"O","subpart":"R","id":"75.1719-4","citation":"30 CFR 75.1719-4","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.523-3","heading":"Automatic emergency-parking brakes.","id":"75.523-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"(a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking brakes in accordance with the following schedule.\n\n(1) On and after May 23, 1989—\n\n(i) All new equipment ordered; and\n\n(ii) All equipment originally furnished with or retrofitted with automatic emergency-parking brakes which meet the requirements of this section.\n\n(2) On and after May 23, 1991, all other equipment.\n\n(b) Automatic emergency-parking brakes shall—\n\n(1) Be activated immediately by the emergency deenergization device required by 30 CFR 75.523-1 and 75.523-2;\n\n(2) Engage automatically within 5.0 seconds when the equipment is deenergized;\n\n(3) Safely bring the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(4) Hold the equipment stationary despite any contraction of brake parts, exhaustion of any non-mechanical source of energy, or leakage; and\n\n(5) Release only by a manual control that does not operate any other equipment function.\n\n(c) Automatic emergency-parking brakes shall include a means in the equipment operator's compartment to—\n\n(1) Apply the brakes manually without deenergizing the equipment; and\n\n(2) Release and reengage the brakes without energizing the equipment.\n\n(d) On and after November 24, 1989, rubber-tired, self-propelled electric face equipment not covered by paragraph (a) of this section shall be equipped with a means incorporated on the equipment and operable from each tramming station to hold the equipment stationary—\n\n(1) On the maximum grade on which it is operated; and\n\n(2) Despite any contraction of components, exhaustion of any non-mechanical source of energy, or leakage.\n\n(e) The brake systems required by paragraphs (a) or (d) of this section shall be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n[54 FR 12412, Mar. 24, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1103-4","heading":"Automatic fire sensor and warning device systems; installation; minimum requirements.","id":"75.1103-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Effective December 31, 2009, automatic fire sensor and warning device systems that use carbon monoxide sensors shall provide identification of fire along all belt conveyors.\n\n(1) Carbon monoxide sensors shall be installed at the following locations:\n\n(i) Not more than 100 feet downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up. If the belt drive, tailpiece, and/or take-up for a single transfer point are installed together in the same air course, and the distance between the units is less than 100 feet, they may be monitored with one sensor downwind of the last component. If the distance between the units exceeds 100 feet, additional sensors are required downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up;\n\n(ii) Not more than 100 feet downwind of each section loading point;\n\n(iii) Along the belt entry so that the spacing between sensors does not exceed 1,000 feet. Where air velocities are less than 50 feet per minute, spacing must not exceed 350 feet; and\n\n(iv) The mine operator shall indicate the locations of all carbon monoxide sensors on the mine maps required by §§ 75.1200 and 75.1505 of this part.\n\n(2) Where used, sensors responding to radiation, smoke, gases, or other indications of fire, shall be spaced at regular intervals to provide protection equivalent to carbon monoxide sensors, and installed within the time specified in paragraph (a)(3) of this section.\n\n(3) When the distance from the tailpiece at loading points to the first outby sensor reaches the spacing requirements in § 75.1103-4(a)(1)(iii), an additional sensor shall be installed and put in operation within 24 production shift hours. When sensors of the kind described in paragraph (a)(2) of this section are used, they shall be installed and put in operation within 24 production shift hours after the equivalent distance which has been established for the sensor from the tailpiece at loading points to the first outby sensor is first reached.\n\n(b) Automatic fire sensor and warning device systems shall be installed so as to minimize the possibility of damage from roof falls and the moving belt and its load. Sensors must be installed near the center in the upper third of the entry, in a manner that does not expose personnel working on the system to unsafe conditions. Sensors must not be located in abnormally high areas or in other locations where air flow patterns do not permit products of combustion to be carried to the sensors.\n\n(c) Infrared, ultraviolet, and other sensors whose effectiveness is impaired by contamination shall be protected from dust, dirt, and moisture.\n\n(d) The voltage of automatic fire sensor and warning device systems shall not exceed 120 volts.\n\n(e) Except when power must be cut off in the mine under the provisions of § 75.313, automatic fire sensor and warning device systems shall be capable of giving warning of fire for a minimum of 4 hours after the source of power to the belt is removed unless the belt haulageway is examined for hot rollers and fire as provided in paragraph (e) (1) or (2) of this section.\n\n(1) When an unplanned removal of power from the belt occurs an examination for hot rollers and fire in the operating belts of a conveyor system shall be completed within 2 hours after the belt has stopped.\n\n(2) When a preplanned removal of power from the belt occurs an examination for hot rollers and fire on the operating belts of a conveyor system may commence not more than 30 minutes before the belts are stopped and shall be completed within 2 hours after the examination is commenced, or the examination shall be commenced when the belts are stopped and completed within 2 hours after the belts are stopped.\n\n[37 FR 16545, Aug. 16, 1972, as amended at 57 FR 20928, May 15, 1992; 73 FR 80614, Dec. 31, 2008]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609017","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}