{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"4609010","name":"Covington Coal Company #1 Mine","status":"Abandoned","status_date":"2021-02-01","mine_type":"Surface","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Boone","nearest_town":"Ashford","operator_id":"0123931","operator_name":"Covington Coal Company LLC","controller_id":"C06675","controller_name":"Peter K  Moran","district":"C04","office":"Madison WV Field Office","employees":0,"latitude":38.199167,"longitude":-81.693889},"coverage":{"contributingSources":14,"registeredSources":20,"sourceRows":1475},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4609010","name":"Covington Coal Company #1 Mine"},"operator":{"type":"operator","id":"0123931","name":"Covington Coal Company LLC"},"controller":{"type":"controller","id":"C06675","name":"Peter K  Moran"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C14644","name":"Andrew B  Jordon"},"object":{"type":"mine","id":"4609010","name":"Covington Coal Company #1 Mine"},"validFrom":"1992-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609010|C14644|1992-06-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P21951","name":"Pritchard Mining Co., Inc."},"object":{"type":"mine","id":"4609010","name":"Covington Coal Company #1 Mine"},"validFrom":"2003-10-28","validTo":"2012-07-16","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609010|P21951|2003-10-28|2012-07-16"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14644","name":"Andrew B  Jordon"},"object":{"type":"operator","id":"P21951","name":"Pritchard Mining Co., Inc."},"validFrom":"2003-10-28","validTo":"2012-07-16","current":false,"derived":true,"evidenceMineId":"4609010","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609010|P21951|2003-10-28|C14644|1992-06-01|93506"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0123931","name":"Covington Coal Company LLC"},"object":{"type":"mine","id":"4609010","name":"Covington Coal Company #1 Mine"},"validFrom":"2012-07-17","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609010|0123931|2012-07-17|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C06675","name":"Peter K  Moran"},"object":{"type":"mine","id":"4609010","name":"Covington Coal Company #1 Mine"},"validFrom":"2012-07-17","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609010|C06675|2012-07-17|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C06675","name":"Peter K  Moran"},"object":{"type":"operator","id":"0123931","name":"Covington Coal Company LLC"},"validFrom":"2012-07-17","validTo":null,"current":true,"derived":true,"evidenceMineId":"4609010","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4609010|0123931|2012-07-17|C06675|2012-07-17|72744"}}],"coverage":{"historyRecords":2,"edgeCount":6,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":12,"firstDate":"2005-06-13","lastDate":"2014-05-23","metrics":{"daysLost":42,"injuries":12,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"214756","DOCUMENT_NO":"220141600008","ACCIDENT_DT":"05/23/2014","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall from machine","OCCUPATION":"Outside foreman, Leadman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Operator stepped out of cab of dozer to use bathroom. He thinks he blacked out and fell off D10R Cat dozer. Hit his head and elbow as he fell. He does take blood pressure medicine - which may have caused him to black out.","sourceDate":"2014-05-23"},{"SOURCE_ROW_NUMBER":"188799","DOCUMENT_NO":"220141000001","ACCIDENT_DT":"03/18/2014","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"FALLING/SLIDING/ROLLING MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Mechanic helper","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Wet soft muddy ground cause blocks to sink. Truck was blocked with 6\"x36\" wooden blocks. Front brakes and rotors were being replaced. Truck was blocked on drivers side. Started to jack up passenger when blocks gave way in the soft ground causing the truck to shift side ways and fall off one of the blocks.","sourceDate":"2014-03-18"},{"SOURCE_ROW_NUMBER":"51201","DOCUMENT_NO":"220090890098","ACCIDENT_DT":"03/11/2009","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Pumper","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"Employee was climbing the ladder on a Cat 777C rock truck. While climbing the ladder, he bumped his foot on the ladder which caused injury to right foot toe joint.","sourceDate":"2009-03-11"},{"SOURCE_ROW_NUMBER":"262154","DOCUMENT_NO":"220083530027","ACCIDENT_DT":"12/09/2008","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Greaser, Grease man, Oiler, Lube man, Dragline oiler","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"Mounting 922C endloader. Slipped when he lost his footing, catching himself with handrails resulting in pulling his right shoulder.","sourceDate":"2008-12-09"},{"SOURCE_ROW_NUMBER":"154492","DOCUMENT_NO":"220083090047","ACCIDENT_DT":"10/28/2008","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Drill operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Operator was dismounting a drill. As he put his left foot on the ground, it went into a void, or hole, in the bench causing his foot to turn toes up. This stretched the back of heel and back of calf. He still had his other foot and both hands on the ladder, preventing him from putting his full weight on his foot.","sourceDate":"2008-10-28"},{"SOURCE_ROW_NUMBER":"201709","DOCUMENT_NO":"220082820044","ACCIDENT_DT":"10/06/2008","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Cutting zip ties with knife, when tie cut/stabbed leg.","sourceDate":"2008-10-06"},{"SOURCE_ROW_NUMBER":"219066","DOCUMENT_NO":"220081070041","ACCIDENT_DT":"04/07/2008","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was lifting battery out of battery crate on lower end of maintenance area for grader. Side of crate broke causing employee to fall. He said he bruised his left ankle. He said he was OK and didn't need an EMT or did not need medical attention. I told him we would fill out a report and he said OK.","sourceDate":"2008-04-07"},{"SOURCE_ROW_NUMBER":"206105","DOCUMENT_NO":"220072900055","ACCIDENT_DT":"09/05/2007","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"EE was backing up in a D10 Dozer and backed over a rock causing the dozer to hit down on the fill jarring his back. He decided it was not necessary to go to the doctor's office at this time and kept working.","sourceDate":"2007-09-05"},{"SOURCE_ROW_NUMBER":"111258","DOCUMENT_NO":"220071930065","ACCIDENT_DT":"06/28/2007","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to lower level, NEC","OCCUPATION":"Crane operator, Mobile equipment operator (MEO), Dragline operator, Dropball operator, Rigger","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE stated that he was standing on a berm and stumbled which resulted in falling approx 3' onto his shoulder. Shoulder jammed on left side & right shin had small abrasion.","sourceDate":"2007-06-28"},{"SOURCE_ROW_NUMBER":"42608","DOCUMENT_NO":"220062630037","ACCIDENT_DT":"08/16/2006","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Using a grinder on a piece of equipment that he was welding on, when a piece went into his eye.","sourceDate":"2006-08-16"},{"SOURCE_ROW_NUMBER":"119924","DOCUMENT_NO":"220062000034","ACCIDENT_DT":"07/13/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Haul/Off road/Coal/Ore/Pit/Quarry/Rock/Rubber tire truck driver, Transportation truck driver","NO_INJURIES":"1","DAYS_LOST":"34","NARRATIVE":"During the day, EE loaded wet hole bags and he also stated that he was jostled around in his truck by a rock. We loaded a total of 120 wet hole bags, which is not normal duty. EE stated pain got worse as day went on. Back hurting, not sure what actually happened.","sourceDate":"2006-07-13"},{"SOURCE_ROW_NUMBER":"262153","DOCUMENT_NO":"220051730022","ACCIDENT_DT":"06/13/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"Mechanic was working on lights on 301 D10N when operator EE went to get off of dozer to use the bathroom when he slipped and fell on push arm of dozer. NOTE: He missed 6/14/05, worked thru 6/15/05 and missed 6/16/05 and 06/17/05","sourceDate":"2005-06-13"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2021-02-01","lastDate":"2021-02-01","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":70,"firstDate":"2004-01-30","lastDate":"2015-05-14","metrics":{"ss":30,"delinquent":64,"recentRows":0,"paidPenalty":12592,"proposedPenalty":38330,"currentAssessment":38330},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1883068","VIOLATION_NO":"9056332","ISSUE_DT":"05/14/2015","CFR_STANDARD_CD":"50.20","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2015-05-14"},{"SOURCE_ROW_NUMBER":"1883067","VIOLATION_NO":"9056327","ISSUE_DT":"04/29/2015","CFR_STANDARD_CD":"50.30(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2015-04-29"},{"SOURCE_ROW_NUMBER":"1883020","VIOLATION_NO":"9004807","ISSUE_DT":"10/06/2014","CFR_STANDARD_CD":"77.410(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2014-10-06"},{"SOURCE_ROW_NUMBER":"1859863","VIOLATION_NO":"9007136","ISSUE_DT":"04/21/2014","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"2000.00","CURRENT_ASSESSMENT_AMT":"2000.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-04-21"},{"SOURCE_ROW_NUMBER":"1859862","VIOLATION_NO":"9007135","ISSUE_DT":"04/21/2014","CFR_STANDARD_CD":"71.600","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-04-21"},{"SOURCE_ROW_NUMBER":"1859861","VIOLATION_NO":"9007134","ISSUE_DT":"04/21/2014","CFR_STANDARD_CD":"77.1605(k)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"138.00","CURRENT_ASSESSMENT_AMT":"138.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-04-21"},{"SOURCE_ROW_NUMBER":"1859860","VIOLATION_NO":"9007133","ISSUE_DT":"04/16/2014","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-04-16"},{"SOURCE_ROW_NUMBER":"1859859","VIOLATION_NO":"9007132","ISSUE_DT":"04/16/2014","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"22600.00","CURRENT_ASSESSMENT_AMT":"22600.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2014-04-16"},{"SOURCE_ROW_NUMBER":"1859858","VIOLATION_NO":"9007131","ISSUE_DT":"04/15/2014","CFR_STANDARD_CD":"77.1109(c)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-04-15"},{"SOURCE_ROW_NUMBER":"1859857","VIOLATION_NO":"9007129","ISSUE_DT":"04/15/2014","CFR_STANDARD_CD":"77.1600(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-04-15"},{"SOURCE_ROW_NUMBER":"1859856","VIOLATION_NO":"9007128","ISSUE_DT":"04/14/2014","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-04-14"},{"SOURCE_ROW_NUMBER":"1859855","VIOLATION_NO":"9007127","ISSUE_DT":"04/14/2014","CFR_STANDARD_CD":"77.1606(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-04-14"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":58,"firstDate":"2005-04-05","lastDate":"2014-10-28","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":2,"validSamples":56,"maxConcentration":1.636,"concentrationTotal":13.989},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1639995","CASS_NUM":"58169750","SMP_TAKEN_DT":"10/28/2014","CONC":".051","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-10-28"},{"SOURCE_ROW_NUMBER":"1585083","CASS_NUM":"58170030","SMP_TAKEN_DT":"10/28/2014","CONC":".078","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"Invalid Code","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-10-28"},{"SOURCE_ROW_NUMBER":"1538264","CASS_NUM":"58169838","SMP_TAKEN_DT":"10/28/2014","CONC":".015","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-10-28"},{"SOURCE_ROW_NUMBER":"1427731","CASS_NUM":"58169892","SMP_TAKEN_DT":"10/28/2014","CONC":".046","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-10-28"},{"SOURCE_ROW_NUMBER":"388386","CASS_NUM":"58169920","SMP_TAKEN_DT":"10/28/2014","CONC":".032","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-10-28"},{"SOURCE_ROW_NUMBER":"1392298","CASS_NUM":"58155229","SMP_TAKEN_DT":"4/21/2014","CONC":".208","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-04-21"},{"SOURCE_ROW_NUMBER":"1106332","CASS_NUM":"58155147","SMP_TAKEN_DT":"4/21/2014","CONC":".296","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-04-21"},{"SOURCE_ROW_NUMBER":"1058339","CASS_NUM":"58155328","SMP_TAKEN_DT":"4/21/2014","CONC":".05","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-04-21"},{"SOURCE_ROW_NUMBER":"1000384","CASS_NUM":"58155222","SMP_TAKEN_DT":"4/21/2014","CONC":".425","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL STRIP OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-04-21"},{"SOURCE_ROW_NUMBER":"712442","CASS_NUM":"58155315","SMP_TAKEN_DT":"4/21/2014","CONC":".079","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-04-21"},{"SOURCE_ROW_NUMBER":"1615915","CASS_NUM":"58124434","SMP_TAKEN_DT":"10/29/2013","CONC":".205","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-10-29"},{"SOURCE_ROW_NUMBER":"1568835","CASS_NUM":"58124340","SMP_TAKEN_DT":"10/29/2013","CONC":".14","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-10-29"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":2,"firstDate":"2007-03-20","lastDate":"2007-03-20","metrics":{"linkedIssuances":2},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":975,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":7,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":195,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":7,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2003-10-28","lastDate":"2012-07-17","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":43,"firstDate":"2004-01-30","lastDate":"2021-01-11","metrics":{"inspectors":50,"recentRows":1,"onSiteHours":516,"inspectionHours":938.75,"inspectionSamples":48},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"536627","EVENT_NO":"6317953","INSPECTION_BEGIN_DT":"01/11/2021","INSPECTION_END_DT":"02/16/2021","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"18","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2021-01-11"},{"SOURCE_ROW_NUMBER":"436929","EVENT_NO":"6316046","INSPECTION_BEGIN_DT":"04/06/2020","INSPECTION_END_DT":"04/06/2020","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.75","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2020-04-06"},{"SOURCE_ROW_NUMBER":"706967","EVENT_NO":"6315146","INSPECTION_BEGIN_DT":"10/31/2019","INSPECTION_END_DT":"11/04/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2019-10-31"},{"SOURCE_ROW_NUMBER":"556232","EVENT_NO":"6316005","INSPECTION_BEGIN_DT":"05/09/2019","INSPECTION_END_DT":"05/09/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2019-05-09"},{"SOURCE_ROW_NUMBER":"575001","EVENT_NO":"6314273","INSPECTION_BEGIN_DT":"10/11/2018","INSPECTION_END_DT":"10/15/2018","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.75","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2018-10-11"},{"SOURCE_ROW_NUMBER":"448818","EVENT_NO":"6313347","INSPECTION_BEGIN_DT":"05/30/2018","INSPECTION_END_DT":"05/30/2018","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2018-05-30"},{"SOURCE_ROW_NUMBER":"781350","EVENT_NO":"6313315","INSPECTION_BEGIN_DT":"10/02/2017","INSPECTION_END_DT":"10/03/2017","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2017-10-02"},{"SOURCE_ROW_NUMBER":"306276","EVENT_NO":"6313308","INSPECTION_BEGIN_DT":"06/05/2017","INSPECTION_END_DT":"06/05/2017","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2017-06-05"},{"SOURCE_ROW_NUMBER":"910547","EVENT_NO":"6311221","INSPECTION_BEGIN_DT":"10/18/2016","INSPECTION_END_DT":"12/22/2016","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2016-10-18"},{"SOURCE_ROW_NUMBER":"599762","EVENT_NO":"6309726","INSPECTION_BEGIN_DT":"06/21/2016","INSPECTION_END_DT":"06/23/2016","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"17","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2016-06-21"},{"SOURCE_ROW_NUMBER":"716152","EVENT_NO":"6309784","INSPECTION_BEGIN_DT":"05/06/2016","INSPECTION_END_DT":"07/01/2016","ACTIVITY_CODE":"E17","ACTIVITY":"Special Emphasis Programs","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2016-05-06"},{"SOURCE_ROW_NUMBER":"523474","EVENT_NO":"6310870","INSPECTION_BEGIN_DT":"03/24/2016","INSPECTION_END_DT":"05/03/2016","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"20","SUM_TOTAL_ON_SITE_HOURS":"8.5","sourceDate":"2016-03-24"}]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":10,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2004":{"hours":43533,"employees":17,"production":200093},"2005":{"hours":79488,"employees":33,"production":328441},"2006":{"hours":89868,"employees":37,"production":325348},"2007":{"hours":99885,"employees":40,"production":387128},"2008":{"hours":102842,"employees":41,"production":345352},"2009":{"hours":39059,"employees":24,"production":79656},"2013":{"hours":25539,"employees":16,"production":30531},"2014":{"hours":10489,"employees":14,"production":23655}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":25,"firstDate":"2005-09-28","lastDate":"2013-10-29","metrics":{"recentRows":0,"doseOver100":4,"actDoseTotal":1692,"pelDoseTotal":851},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"250474","EVENT_NO":"6302718","SURVEY_DATE":"10/29/2013","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"77","PEL_DOSE_90":"18","SURVEY_TYPE":"I","sourceDate":"2013-10-29"},{"SOURCE_ROW_NUMBER":"250473","EVENT_NO":"6302718","SURVEY_DATE":"10/29/2013","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"42","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2013-10-29"},{"SOURCE_ROW_NUMBER":"250472","EVENT_NO":"6302718","SURVEY_DATE":"10/29/2013","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"62","PEL_DOSE_90":"18","SURVEY_TYPE":"I","sourceDate":"2013-10-29"},{"SOURCE_ROW_NUMBER":"250471","EVENT_NO":"6302718","SURVEY_DATE":"10/29/2013","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"51","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2013-10-29"},{"SOURCE_ROW_NUMBER":"250470","EVENT_NO":"6302718","SURVEY_DATE":"10/29/2013","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"46","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2013-10-29"},{"SOURCE_ROW_NUMBER":"250469","EVENT_NO":"6297773","SURVEY_DATE":"12/05/2012","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"94","PEL_DOSE_90":"47","SURVEY_TYPE":"I","sourceDate":"2012-12-05"},{"SOURCE_ROW_NUMBER":"250468","EVENT_NO":"6297773","SURVEY_DATE":"12/05/2012","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"101","PEL_DOSE_90":"48","SURVEY_TYPE":"I","sourceDate":"2012-12-05"},{"SOURCE_ROW_NUMBER":"250467","EVENT_NO":"6297773","SURVEY_DATE":"12/05/2012","OCCUPATION_CD_DESC":"HIGHWALL DRILL OPERATOR","MACHINE_CD":"21","MANUFACTURER_CD":"053","ACT_DOSE_85":"86","PEL_DOSE_90":"27","SURVEY_TYPE":"I","sourceDate":"2012-12-05"},{"SOURCE_ROW_NUMBER":"250466","EVENT_NO":"6297773","SURVEY_DATE":"12/05/2012","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"54","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2012-12-05"},{"SOURCE_ROW_NUMBER":"250465","EVENT_NO":"6297773","SURVEY_DATE":"12/05/2012","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"106","PEL_DOSE_90":"51","SURVEY_TYPE":"I","sourceDate":"2012-12-05"},{"SOURCE_ROW_NUMBER":"250464","EVENT_NO":"4123920","SURVEY_DATE":"02/10/2009","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"94","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2009-02-10"},{"SOURCE_ROW_NUMBER":"250463","EVENT_NO":"4123920","SURVEY_DATE":"02/10/2009","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"71","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2009-02-10"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":11,"firstDate":"2005-09-28","lastDate":"2008-10-22","metrics":{"recentRows":0,"voidSamples":2,"maxQuartzPct":50.9,"validSamples":9,"quartzPctTotal":221.7},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"14839","CASSETTE_NO":"50990110","SAMPLE_DT":"10/22/2008","QUARTZ_PCT":"29.8","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"UNACCEPTABLE TIMEFRAME","sourceDate":"2008-10-22"},{"SOURCE_ROW_NUMBER":"165027","CASSETTE_NO":"57774025","SAMPLE_DT":"09/18/2008","QUARTZ_PCT":"27.2","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-09-18"},{"SOURCE_ROW_NUMBER":"43439","CASSETTE_NO":"57774046","SAMPLE_DT":"09/18/2008","QUARTZ_PCT":"06.4","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-09-18"},{"SOURCE_ROW_NUMBER":"111849","CASSETTE_NO":"50831798","SAMPLE_DT":"12/15/2005","QUARTZ_PCT":"10.3","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-12-15"},{"SOURCE_ROW_NUMBER":"78898","CASSETTE_NO":"50832437","SAMPLE_DT":"11/22/2005","QUARTZ_PCT":"13.4","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-11-22"},{"SOURCE_ROW_NUMBER":"30737","CASSETTE_NO":"50828011","SAMPLE_DT":"11/22/2005","QUARTZ_PCT":"02.4","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-11-22"},{"SOURCE_ROW_NUMBER":"151689","CASSETTE_NO":"50827079","SAMPLE_DT":"11/03/2005","QUARTZ_PCT":"21.6","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-11-03"},{"SOURCE_ROW_NUMBER":"120335","CASSETTE_NO":"50814212","SAMPLE_DT":"10/25/2005","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2005-10-25"},{"SOURCE_ROW_NUMBER":"122258","CASSETTE_NO":"57568139","SAMPLE_DT":"09/28/2005","QUARTZ_PCT":"50.9","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-09-28"},{"SOURCE_ROW_NUMBER":"82827","CASSETTE_NO":"57568328","SAMPLE_DT":"09/28/2005","QUARTZ_PCT":"28.8","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-09-28"},{"SOURCE_ROW_NUMBER":"58280","CASSETTE_NO":"57568347","SAMPLE_DT":"09/28/2005","QUARTZ_PCT":"30.9","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-09-28"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":70,"firstDate":"2004-01-30","lastDate":"2015-05-14","metrics":{"ss":30,"amountDue":38330,"contested":0,"amountPaid":12592,"recentRows":0,"section104d":2,"unterminated":0,"proposedPenalty":38330},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2843159","VIOLATION_NO":"9056332","VIOLATION_ISSUE_DT":"05/14/2015","SIG_SUB":"N","PART_SECTION":"50.20","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/07/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2015-05-14"},{"SOURCE_ROW_NUMBER":"2843158","VIOLATION_NO":"9056327","VIOLATION_ISSUE_DT":"04/29/2015","SIG_SUB":"N","PART_SECTION":"50.30(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"05/14/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2015-04-29"},{"SOURCE_ROW_NUMBER":"2843185","VIOLATION_NO":"9004807","VIOLATION_ISSUE_DT":"10/06/2014","SIG_SUB":"N","PART_SECTION":"77.410(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/07/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2014-10-06"},{"SOURCE_ROW_NUMBER":"2843157","VIOLATION_NO":"9007136","VIOLATION_ISSUE_DT":"04/21/2014","SIG_SUB":"Y","PART_SECTION":"77.502","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"04/21/2014","PROPOSED_PENALTY":"2000","AMOUNT_DUE":"2000","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2014-04-21"},{"SOURCE_ROW_NUMBER":"2843156","VIOLATION_NO":"9007135","VIOLATION_ISSUE_DT":"04/21/2014","SIG_SUB":"N","PART_SECTION":"71.600","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"10","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/21/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2014-04-21"},{"SOURCE_ROW_NUMBER":"2843155","VIOLATION_NO":"9007134","VIOLATION_ISSUE_DT":"04/21/2014","SIG_SUB":"Y","PART_SECTION":"77.1605(k)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/21/2014","PROPOSED_PENALTY":"138","AMOUNT_DUE":"138","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2014-04-21"},{"SOURCE_ROW_NUMBER":"2843154","VIOLATION_NO":"9007133","VIOLATION_ISSUE_DT":"04/16/2014","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/21/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2014-04-16"},{"SOURCE_ROW_NUMBER":"2843153","VIOLATION_NO":"9007132","VIOLATION_ISSUE_DT":"04/16/2014","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Highly","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"Reckless","TERMINATION_DT":"04/23/2014","PROPOSED_PENALTY":"22600","AMOUNT_DUE":"22600","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2014-04-16"},{"SOURCE_ROW_NUMBER":"2843152","VIOLATION_NO":"9007131","VIOLATION_ISSUE_DT":"04/15/2014","SIG_SUB":"N","PART_SECTION":"77.1109(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/15/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2014-04-15"},{"SOURCE_ROW_NUMBER":"2843151","VIOLATION_NO":"9007129","VIOLATION_ISSUE_DT":"04/15/2014","SIG_SUB":"N","PART_SECTION":"77.1600(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/15/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2014-04-15"},{"SOURCE_ROW_NUMBER":"2843150","VIOLATION_NO":"9007128","VIOLATION_ISSUE_DT":"04/14/2014","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/15/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2014-04-14"},{"SOURCE_ROW_NUMBER":"2843149","VIOLATION_NO":"9007127","VIOLATION_ISSUE_DT":"04/14/2014","SIG_SUB":"N","PART_SECTION":"77.1606(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/14/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-04-14"}]}],"safety":{"href":"/api/v1/mines/4609010/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4609010/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Preparation and submission of MSHA Report Form 7000-1—Mine Accident, Injury, and Illness Report.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-I/part-50/subpart-C/section-50.20","part":"50","subchapter":"I","subpart":"C","id":"50.20","citation":"30 CFR 50.20","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER I—ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND PRODUCTION IN MINES","partHeading":"PART 50—NOTIFICATION, INVESTIGATION, REPORTS AND RECORDS OF ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND COAL PRODUCTION IN MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Preparation and submission of MSHA Form 7000-2—Quarterly Employment and Coal Production Report.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-I/part-50/subpart-D/section-50.30","part":"50","subchapter":"I","subpart":"D","id":"50.30","citation":"30 CFR 50.30","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER I—ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND PRODUCTION IN MINES","partHeading":"PART 50—NOTIFICATION, INVESTIGATION, REPORTS AND RECORDS OF ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND COAL PRODUCTION IN MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":1},{"chapter":"I","heading":"Drinking water; general.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-71/subpart-G/section-71.600","part":"71","subchapter":"O","subpart":"G","id":"71.600","citation":"30 CFR 71.600","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 71—MANDATORY HEALTH STANDARDS—SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":1},{"chapter":"I","heading":"Loading and haulage; general.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1600","part":"77","subchapter":"O","subpart":"Q","id":"77.1600","citation":"30 CFR 77.1600","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4609010","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}