{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4608963","name":"Mine No. 1","status":"Abandoned and Sealed","status_date":"2005-04-25","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Mcdowell","nearest_town":"Iaeger","operator_id":"0050384","operator_name":"Harman Branch Mining, Inc.","controller_id":"0067993","controller_name":"Hung  Q  Nguyen","district":"C04","office":"Beckley District","employees":0,"latitude":37.464444,"longitude":-81.776111},"coverage":{"contributingSources":12,"registeredSources":20,"sourceRows":311},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4608963","name":"Mine No. 1"},"operator":{"type":"operator","id":"0050384","name":"Harman Branch Mining, Inc."},"controller":{"type":"controller","id":"0067993","name":"Hung  Q  Nguyen"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"0050384","name":"Harman Branch Mining, Inc."},"object":{"type":"mine","id":"4608963","name":"Mine No. 1"},"validFrom":"2002-06-11","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608963|0050384|2002-06-11|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C16007","name":"Daniel S  Jordan"},"object":{"type":"mine","id":"4608963","name":"Mine No. 1"},"validFrom":"2002-06-11","validTo":"2007-02-27","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608963|C16007|2002-06-11|2007-02-27"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C16007","name":"Daniel S  Jordan"},"object":{"type":"operator","id":"0050384","name":"Harman Branch Mining, Inc."},"validFrom":"2002-06-11","validTo":"2007-02-27","current":false,"derived":true,"evidenceMineId":"4608963","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608963|0050384|2002-06-11|C16007|2002-06-11|97990"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0067993","name":"Hung  Q  Nguyen"},"object":{"type":"mine","id":"4608963","name":"Mine No. 1"},"validFrom":"2007-02-28","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608963|0067993|2007-02-28|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0067993","name":"Hung  Q  Nguyen"},"object":{"type":"operator","id":"0050384","name":"Harman Branch Mining, Inc."},"validFrom":"2007-02-28","validTo":null,"current":true,"derived":true,"evidenceMineId":"4608963","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608963|0050384|2002-06-11|0067993|2007-02-28|9537"}}],"coverage":{"historyRecords":2,"edgeCount":5,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":3,"firstDate":"2003-02-28","lastDate":"2004-08-05","metrics":{"daysLost":1,"injuries":1,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"270591","DOCUMENT_NO":"220042290114","ACCIDENT_DT":"08/05/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"Fixing wheel unit. Chain slipped, fell on left knee, which pushed leg forward causing sprained foot & ankle.","sourceDate":"2004-08-05"},{"SOURCE_ROW_NUMBER":"158786","DOCUMENT_NO":"220032510002","ACCIDENT_DT":"09/02/2003","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"ROCK FALL APPROX. 20'WIDE, 7'THICK & 125'LONG. FROM SPAD #40 ACROSS 2 INTERSECTION. MINE ADVANCED ON 50 BY 90 CENTERS BLOCKED INTAKE ESCAPEWAY, REROUTED STOPPING LINE AND TIMBERED CRIBBED & DANGERED OFF.","sourceDate":"2003-09-02"},{"SOURCE_ROW_NUMBER":"163086","DOCUMENT_NO":"220030660012","ACCIDENT_DT":"02/28/2003","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"THE AFFECTED AREA HAD ADDITIONAL ROOF SUPPORT INCLUDING 7' ROOF BOLTS, TIMBER AND CRIBS WE KNOW IT WAS A FAULTY AREA. IT IS IN AREA WHERE ADD SIZE BLOCK ARE WHERE SECTION BELT TURNED OFF MAINS . ADDITIONAL CRIBS WERE SET AROUND FALL AND STOPPING LINE WAS SET OVER FOR INTAKE.","sourceDate":"2003-02-28"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2005-04-25","lastDate":"2005-04-25","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":37,"firstDate":"2002-10-25","lastDate":"2005-04-06","metrics":{"ss":12,"delinquent":37,"recentRows":0,"paidPenalty":2644,"proposedPenalty":2644,"currentAssessment":2644},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"794311","VIOLATION_NO":"7229693","ISSUE_DT":"04/06/2005","CFR_STANDARD_CD":"77.1109(c)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-04-06"},{"SOURCE_ROW_NUMBER":"794260","VIOLATION_NO":"7229670","ISSUE_DT":"02/10/2005","CFR_STANDARD_CD":"75.1714-3(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-02-10"},{"SOURCE_ROW_NUMBER":"794259","VIOLATION_NO":"7229669","ISSUE_DT":"02/10/2005","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-02-10"},{"SOURCE_ROW_NUMBER":"789386","VIOLATION_NO":"7222658","ISSUE_DT":"09/27/2004","CFR_STANDARD_CD":"75.800-3(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-09-27"},{"SOURCE_ROW_NUMBER":"789366","VIOLATION_NO":"7222576","ISSUE_DT":"04/14/2004","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"107.00","CURRENT_ASSESSMENT_AMT":"107.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-14"},{"SOURCE_ROW_NUMBER":"789365","VIOLATION_NO":"7222575","ISSUE_DT":"04/14/2004","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-14"},{"SOURCE_ROW_NUMBER":"789355","VIOLATION_NO":"7222563","ISSUE_DT":"02/26/2004","CFR_STANDARD_CD":"75.800-4","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"114.00","CURRENT_ASSESSMENT_AMT":"114.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-02-26"},{"SOURCE_ROW_NUMBER":"789354","VIOLATION_NO":"7222562","ISSUE_DT":"02/26/2004","CFR_STANDARD_CD":"75.311(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"114.00","CURRENT_ASSESSMENT_AMT":"114.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-02-26"},{"SOURCE_ROW_NUMBER":"789353","VIOLATION_NO":"7222561","ISSUE_DT":"02/25/2004","CFR_STANDARD_CD":"77.1109(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"114.00","CURRENT_ASSESSMENT_AMT":"114.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-02-25"},{"SOURCE_ROW_NUMBER":"789352","VIOLATION_NO":"7222560","ISSUE_DT":"02/25/2004","CFR_STANDARD_CD":"75.333(b)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"177.00","CURRENT_ASSESSMENT_AMT":"177.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-02-25"},{"SOURCE_ROW_NUMBER":"789356","VIOLATION_NO":"7224285","ISSUE_DT":"01/06/2004","CFR_STANDARD_CD":"75.325(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-01-06"},{"SOURCE_ROW_NUMBER":"789341","VIOLATION_NO":"7222553","ISSUE_DT":"11/05/2003","CFR_STANDARD_CD":"75.523-1(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"91.00","CURRENT_ASSESSMENT_AMT":"91.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-11-05"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":155,"firstDate":"2002-10-14","lastDate":"2005-03-03","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":7,"validSamples":148,"maxConcentration":4.943,"concentrationTotal":111.518},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"971248","CASS_NUM":"57541991","SMP_TAKEN_DT":"3/3/2005","CONC":".586","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-03-03"},{"SOURCE_ROW_NUMBER":"862486","CASS_NUM":"57541955","SMP_TAKEN_DT":"3/3/2005","CONC":".592","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER HELPER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-03-03"},{"SOURCE_ROW_NUMBER":"464703","CASS_NUM":"57542236","SMP_TAKEN_DT":"3/3/2005","CONC":"1.241","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-03-03"},{"SOURCE_ROW_NUMBER":"397412","CASS_NUM":"57541950","SMP_TAKEN_DT":"3/3/2005","CONC":".755","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-03-03"},{"SOURCE_ROW_NUMBER":"1446530","CASS_NUM":"57490318","SMP_TAKEN_DT":"1/25/2005","CONC":".763","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-01-25"},{"SOURCE_ROW_NUMBER":"497825","CASS_NUM":"57490188","SMP_TAKEN_DT":"1/25/2005","CONC":"1.044","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-01-25"},{"SOURCE_ROW_NUMBER":"334765","CASS_NUM":"57490362","SMP_TAKEN_DT":"1/25/2005","CONC":"1.122","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-01-25"},{"SOURCE_ROW_NUMBER":"325303","CASS_NUM":"57490313","SMP_TAKEN_DT":"1/25/2005","CONC":".713","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-01-25"},{"SOURCE_ROW_NUMBER":"64035","CASS_NUM":"57490263","SMP_TAKEN_DT":"1/25/2005","CONC":"2.461","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER HELPER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-01-25"},{"SOURCE_ROW_NUMBER":"531992","CASS_NUM":"50686917","SMP_TAKEN_DT":"1/11/2005","CONC":".126","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-01-11"},{"SOURCE_ROW_NUMBER":"1179189","CASS_NUM":"50686965","SMP_TAKEN_DT":"1/10/2005","CONC":".205","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-01-10"},{"SOURCE_ROW_NUMBER":"1207775","CASS_NUM":"50764775","SMP_TAKEN_DT":"1/6/2005","CONC":".109","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-01-06"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2002-06-11","lastDate":"2002-06-11","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":39,"firstDate":"2002-07-16","lastDate":"2005-04-06","metrics":{"inspectors":46,"recentRows":0,"onSiteHours":556.5,"inspectionHours":993.25,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"34305","EVENT_NO":"4105549","INSPECTION_BEGIN_DT":"04/06/2005","INSPECTION_END_DT":"04/06/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2005-04-06"},{"SOURCE_ROW_NUMBER":"25902","EVENT_NO":"4105541","INSPECTION_BEGIN_DT":"03/03/2005","INSPECTION_END_DT":"03/11/2005","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"17.5","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2005-03-03"},{"SOURCE_ROW_NUMBER":"999722","EVENT_NO":"4105538","INSPECTION_BEGIN_DT":"01/05/2005","INSPECTION_END_DT":"03/01/2005","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"67.5","SUM_TOTAL_ON_SITE_HOURS":"33.5","sourceDate":"2005-01-05"},{"SOURCE_ROW_NUMBER":"487462","EVENT_NO":"4106252","INSPECTION_BEGIN_DT":"10/05/2004","INSPECTION_END_DT":"12/02/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"34","SUM_TOTAL_ON_SITE_HOURS":"23","sourceDate":"2004-10-05"},{"SOURCE_ROW_NUMBER":"1016560","EVENT_NO":"4108101","INSPECTION_BEGIN_DT":"10/04/2004","INSPECTION_END_DT":"10/04/2004","ACTIVITY_CODE":"CDB","ACTIVITY":"ACCIDENT PREVENTION SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2004-10-04"},{"SOURCE_ROW_NUMBER":"978581","EVENT_NO":"4103145","INSPECTION_BEGIN_DT":"09/22/2004","INSPECTION_END_DT":"09/23/2004","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2004-09-22"},{"SOURCE_ROW_NUMBER":"928433","EVENT_NO":"4103139","INSPECTION_BEGIN_DT":"07/06/2004","INSPECTION_END_DT":"09/30/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"52.25","SUM_TOTAL_ON_SITE_HOURS":"30","sourceDate":"2004-07-06"},{"SOURCE_ROW_NUMBER":"17918","EVENT_NO":"4107129","INSPECTION_BEGIN_DT":"04/29/2004","INSPECTION_END_DT":"04/29/2004","ACTIVITY_CODE":"CDA","ACTIVITY":"ROOF CONTROL SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2004-04-29"},{"SOURCE_ROW_NUMBER":"70126","EVENT_NO":"4103128","INSPECTION_BEGIN_DT":"04/02/2004","INSPECTION_END_DT":"06/01/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"59","SUM_TOTAL_ON_SITE_HOURS":"37","sourceDate":"2004-04-02"},{"SOURCE_ROW_NUMBER":"664889","EVENT_NO":"4103788","INSPECTION_BEGIN_DT":"02/04/2004","INSPECTION_END_DT":"02/11/2004","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2004-02-04"},{"SOURCE_ROW_NUMBER":"241425","EVENT_NO":"4103121","INSPECTION_BEGIN_DT":"01/05/2004","INSPECTION_END_DT":"03/29/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"73","SUM_TOTAL_ON_SITE_HOURS":"41","sourceDate":"2004-01-05"},{"SOURCE_ROW_NUMBER":"429434","EVENT_NO":"4103119","INSPECTION_BEGIN_DT":"12/22/2003","INSPECTION_END_DT":"12/31/2003","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"18","SUM_TOTAL_ON_SITE_HOURS":"9.5","sourceDate":"2003-12-22"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":13,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2005-Q2":{"hours":0,"employees":0,"production":0},"2005-Q1":{"hours":3566,"employees":8,"production":26778},"2004-Q4":{"hours":4610,"employees":8,"production":18951},"2004-Q3":{"hours":3727,"employees":8,"production":21309},"2004-Q2":{"hours":4798,"employees":11,"production":20305},"2004-Q1":{"hours":4699,"employees":11,"production":20587},"2003-Q4":{"hours":6856,"employees":12,"production":23284},"2003-Q3":{"hours":4760,"employees":10,"production":17236},"2003-Q2":{"hours":4988,"employees":18,"production":20652},"2003-Q1":{"hours":1928,"employees":12,"production":17091},"2002-Q4":{"hours":4691,"employees":11,"production":16907},"2002-Q3":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":4,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002":{"hours":4691,"employees":11,"production":16907},"2003":{"hours":18532,"employees":13,"production":78263},"2004":{"hours":17834,"employees":10,"production":81152},"2005":{"hours":3566,"employees":8,"production":26778}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":10,"firstDate":"2003-04-21","lastDate":"2004-09-22","metrics":{"recentRows":0,"doseOver100":3,"actDoseTotal":806,"pelDoseTotal":617},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"249533","EVENT_NO":"4103145","SURVEY_DATE":"09/22/2004","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"115","PEL_DOSE_90":"99","SURVEY_TYPE":"I","sourceDate":"2004-09-22"},{"SOURCE_ROW_NUMBER":"249532","EVENT_NO":"4103145","SURVEY_DATE":"09/22/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"066","ACT_DOSE_85":"62","PEL_DOSE_90":"38","SURVEY_TYPE":"I","sourceDate":"2004-09-22"},{"SOURCE_ROW_NUMBER":"249531","EVENT_NO":"4103145","SURVEY_DATE":"09/22/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"066","ACT_DOSE_85":"90","PEL_DOSE_90":"70","SURVEY_TYPE":"I","sourceDate":"2004-09-22"},{"SOURCE_ROW_NUMBER":"249530","EVENT_NO":"4103145","SURVEY_DATE":"09/22/2004","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"43","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2004-09-22"},{"SOURCE_ROW_NUMBER":"249529","EVENT_NO":"4103145","SURVEY_DATE":"09/22/2004","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"28","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2004-09-22"},{"SOURCE_ROW_NUMBER":"249528","EVENT_NO":"4102265","SURVEY_DATE":"04/21/2003","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"55","PEL_DOSE_90":"37","SURVEY_TYPE":"I","sourceDate":"2003-04-21"},{"SOURCE_ROW_NUMBER":"249527","EVENT_NO":"4102265","SURVEY_DATE":"04/21/2003","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"50","PEL_DOSE_90":"26","SURVEY_TYPE":"I","sourceDate":"2003-04-21"},{"SOURCE_ROW_NUMBER":"249526","EVENT_NO":"4102265","SURVEY_DATE":"04/21/2003","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"053","ACT_DOSE_85":"139","PEL_DOSE_90":"125","SURVEY_TYPE":"I","sourceDate":"2003-04-21"},{"SOURCE_ROW_NUMBER":"249525","EVENT_NO":"4102265","SURVEY_DATE":"04/21/2003","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"053","ACT_DOSE_85":"98","PEL_DOSE_90":"83","SURVEY_TYPE":"I","sourceDate":"2003-04-21"},{"SOURCE_ROW_NUMBER":"249524","EVENT_NO":"4102265","SURVEY_DATE":"04/21/2003","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"126","PEL_DOSE_90":"112","SURVEY_TYPE":"I","sourceDate":"2003-04-21"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":8,"firstDate":"2002-10-28","lastDate":"2005-03-03","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":4.5,"validSamples":8,"quartzPctTotal":19.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"95623","CASSETTE_NO":"57542236","SAMPLE_DT":"03/03/2005","QUARTZ_PCT":"01.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-03-03"},{"SOURCE_ROW_NUMBER":"130410","CASSETTE_NO":"57490188","SAMPLE_DT":"01/25/2005","QUARTZ_PCT":"01.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-01-25"},{"SOURCE_ROW_NUMBER":"7002","CASSETTE_NO":"57453787","SAMPLE_DT":"04/22/2004","QUARTZ_PCT":"02.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-04-22"},{"SOURCE_ROW_NUMBER":"9143","CASSETTE_NO":"57453753","SAMPLE_DT":"02/24/2004","QUARTZ_PCT":"01.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-02-24"},{"SOURCE_ROW_NUMBER":"103537","CASSETTE_NO":"57443506","SAMPLE_DT":"08/05/2003","QUARTZ_PCT":"02.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-08-05"},{"SOURCE_ROW_NUMBER":"117883","CASSETTE_NO":"57420456","SAMPLE_DT":"05/13/2003","QUARTZ_PCT":"04.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-05-13"},{"SOURCE_ROW_NUMBER":"72544","CASSETTE_NO":"57420325","SAMPLE_DT":"02/04/2003","QUARTZ_PCT":"02.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-02-04"},{"SOURCE_ROW_NUMBER":"47849","CASSETTE_NO":"57419899","SAMPLE_DT":"10/28/2002","QUARTZ_PCT":"02.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-10-28"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":38,"firstDate":"2002-10-25","lastDate":"2005-04-06","metrics":{"ss":12,"amountDue":2644,"contested":0,"amountPaid":2644,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":2644},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2834532","VIOLATION_NO":"7229693","VIOLATION_ISSUE_DT":"04/06/2005","SIG_SUB":"N","PART_SECTION":"77.1109(c)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"04/06/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-04-06"},{"SOURCE_ROW_NUMBER":"2834520","VIOLATION_NO":"7229670","VIOLATION_ISSUE_DT":"02/10/2005","SIG_SUB":"N","PART_SECTION":"75.1714-3(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"02/10/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-02-10"},{"SOURCE_ROW_NUMBER":"2834519","VIOLATION_NO":"7229669","VIOLATION_ISSUE_DT":"02/10/2005","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"3","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"02/14/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-02-10"},{"SOURCE_ROW_NUMBER":"2834535","VIOLATION_NO":"7222658","VIOLATION_ISSUE_DT":"09/27/2004","SIG_SUB":"N","PART_SECTION":"75.800-3(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"2","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/27/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-09-27"},{"SOURCE_ROW_NUMBER":"2834531","VIOLATION_NO":"7222576","VIOLATION_ISSUE_DT":"04/14/2004","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/22/2004","PROPOSED_PENALTY":"107","AMOUNT_DUE":"107","AMOUNT_PAID":"107","CONTESTED_IND":"N","sourceDate":"2004-04-14"},{"SOURCE_ROW_NUMBER":"2834530","VIOLATION_NO":"7222575","VIOLATION_ISSUE_DT":"04/14/2004","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/14/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-04-14"},{"SOURCE_ROW_NUMBER":"2834517","VIOLATION_NO":"7222563","VIOLATION_ISSUE_DT":"02/26/2004","SIG_SUB":"Y","PART_SECTION":"75.800-4","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/26/2004","PROPOSED_PENALTY":"114","AMOUNT_DUE":"114","AMOUNT_PAID":"114","CONTESTED_IND":"N","sourceDate":"2004-02-26"},{"SOURCE_ROW_NUMBER":"2834516","VIOLATION_NO":"7222562","VIOLATION_ISSUE_DT":"02/26/2004","SIG_SUB":"Y","PART_SECTION":"75.311(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/26/2004","PROPOSED_PENALTY":"114","AMOUNT_DUE":"114","AMOUNT_PAID":"114","CONTESTED_IND":"N","sourceDate":"2004-02-26"},{"SOURCE_ROW_NUMBER":"2834515","VIOLATION_NO":"7222561","VIOLATION_ISSUE_DT":"02/25/2004","SIG_SUB":"Y","PART_SECTION":"77.1109(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/25/2004","PROPOSED_PENALTY":"114","AMOUNT_DUE":"114","AMOUNT_PAID":"114","CONTESTED_IND":"N","sourceDate":"2004-02-25"},{"SOURCE_ROW_NUMBER":"2834514","VIOLATION_NO":"7222560","VIOLATION_ISSUE_DT":"02/25/2004","SIG_SUB":"Y","PART_SECTION":"75.333(b)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"3","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/26/2004","PROPOSED_PENALTY":"177","AMOUNT_DUE":"177","AMOUNT_PAID":"177","CONTESTED_IND":"N","sourceDate":"2004-02-25"},{"SOURCE_ROW_NUMBER":"2834518","VIOLATION_NO":"7224285","VIOLATION_ISSUE_DT":"01/06/2004","SIG_SUB":"N","PART_SECTION":"75.325(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"6","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/06/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-01-06"},{"SOURCE_ROW_NUMBER":"2834551","VIOLATION_NO":"7222553","VIOLATION_ISSUE_DT":"11/05/2003","SIG_SUB":"Y","PART_SECTION":"75.523-1(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/06/2003","PROPOSED_PENALTY":"91","AMOUNT_DUE":"91","AMOUNT_PAID":"91","CONTESTED_IND":"N","sourceDate":"2003-11-05"}]}],"safety":{"href":"/api/v1/mines/4608963/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4608963/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":2},{"chapter":"I","heading":"Self-rescue devices; inspection, testing, maintenance, repair, and recordkeeping.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-3","part":"75","subchapter":"O","subpart":"R","id":"75.1714-3","citation":"30 CFR 75.1714-3","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","heading":"Testing, examination and maintenance of circuit breakers; procedures.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-I/section-75.800-3","part":"75","subchapter":"O","subpart":"I","id":"75.800-3","citation":"30 CFR 75.800-3","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1725","heading":"Machinery and equipment; operation and maintenance.","id":"75.1725","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1725","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.800-4","heading":"Testing, examination, and maintenance of circuit breakers; record.","id":"75.800-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-I/section-75.800-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"I","subpartHeading":"Subpart I—Underground High-Voltage Distribution","text":"(a) Recordkeeping. The operator shall make a record of each test, examination, repair, or adjustment of all circuit breakers protecting high-voltage circuits which enter any underground area of the mine.\n\n(b) Record security. These records shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(c) Retention and access. These records shall be retained at a surface location at the mine for at least one year and shall be made available to authorized representatives of the Secretary, the representative of miners, and other interested persons.\n\n[64 FR 43287, Aug. 10, 1999]","occurrenceCount":1},{"chapter":"I","heading":"Main mine fan operation.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.311","part":"75","subchapter":"O","subpart":"D","id":"75.311","citation":"30 CFR 75.311","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","heading":"Air quantity.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.325","part":"75","subchapter":"O","subpart":"D","id":"75.325","citation":"30 CFR 75.325","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Deenergization of self-propelled electric face equipment installation requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-1","part":"75","subchapter":"O","subpart":"F","id":"75.523-1","citation":"30 CFR 75.523-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4608963","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}