{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4608955","name":"Mine No. 2","status":"Abandoned and Sealed","status_date":"2018-08-02","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Mcdowell","nearest_town":"Jolo","operator_id":"0050101","operator_name":"Resurrection Coal Company, Inc.","controller_id":"C09864","controller_name":"Darvin  Rowe","district":"C04","office":"Beckley District","employees":0,"latitude":37.375278,"longitude":-81.741667},"coverage":{"contributingSources":14,"registeredSources":20,"sourceRows":1203},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4608955","name":"Mine No. 2"},"operator":{"type":"operator","id":"0050101","name":"Resurrection Coal Company, Inc."},"controller":{"type":"controller","id":"C09864","name":"Darvin  Rowe"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"0040495","name":"Denver L  Stevens"},"object":{"type":"mine","id":"4608955","name":"Mine No. 2"},"validFrom":"2001-12-05","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608955|0040495|2001-12-05|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0050101","name":"Resurrection Coal Co., Inc."},"object":{"type":"mine","id":"4608955","name":"Mine No. 2"},"validFrom":"2002-02-15","validTo":"2002-07-21","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608955|0050101|2002-02-15|2002-07-21"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C09864","name":"Darvin  Rowe et al"},"object":{"type":"mine","id":"4608955","name":"Mine No. 2"},"validFrom":"2002-02-15","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608955|C09864|2002-02-15|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C09864","name":"Darvin  Rowe et al"},"object":{"type":"operator","id":"0050101","name":"Resurrection Coal Co., Inc."},"validFrom":"2002-02-15","validTo":"2002-07-21","current":false,"derived":true,"evidenceMineId":"4608955","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608955|0050101|2002-02-15|C09864|2002-02-15|80774"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0050042","name":"Lo-Vein Coal, Inc."},"object":{"type":"mine","id":"4608955","name":"Mine No. 2"},"validFrom":"2002-07-22","validTo":"2006-04-11","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608955|0050042|2002-07-22|2006-04-11"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0040495","name":"Denver L  Stevens"},"object":{"type":"operator","id":"0050042","name":"Lo-Vein Coal, Inc."},"validFrom":"2002-07-22","validTo":"2006-04-11","current":false,"derived":true,"evidenceMineId":"4608955","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608955|0050042|2002-07-22|0040495|2001-12-05|74"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0050101","name":"Resurrection Coal Company, Inc."},"object":{"type":"mine","id":"4608955","name":"Mine No. 2"},"validFrom":"2006-04-12","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608955|0050101|2006-04-12|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C09864","name":"Darvin  Rowe et al"},"object":{"type":"operator","id":"0050101","name":"Resurrection Coal Company, Inc."},"validFrom":"2006-04-12","validTo":null,"current":true,"derived":true,"evidenceMineId":"4608955","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608955|0050101|2006-04-12|C09864|2002-02-15|80775"}}],"coverage":{"historyRecords":3,"edgeCount":8,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":4,"firstDate":"2009-11-09","lastDate":"2012-11-17","metrics":{"daysLost":11,"injuries":1,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"236276","DOCUMENT_NO":"220123350003","ACCIDENT_DT":"11/17/2012","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"11","NARRATIVE":"EE was running a 270 tractor that pulls coal in a ram car and had made a turn thru an intersection and had his right arm hanging out of the deck and over the bumper when the ram car bumped out against the tractor bumper it mashed his arm in between the two resulting in an injury he didn't think he hurt it but it started to swell up and decided to get it checked.","sourceDate":"2012-11-17"},{"SOURCE_ROW_NUMBER":"68349","DOCUMENT_NO":"220122070001","ACCIDENT_DT":"07/03/2012","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"We were taking a 10' cut by 16' wide out of #5 heading where we were going under a hollow and as we were cleaning up the cut I saw some of the top drip from the rib and we stopped and backed miner out and was going to set some cribs but in about 10 mins. it started to fall from the face out.","sourceDate":"2012-07-03"},{"SOURCE_ROW_NUMBER":"137157","DOCUMENT_NO":"220120930018","ACCIDENT_DT":"03/23/2012","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"INUNDATION","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"We were starting a cut in #7 heading and was cutting 10' on right side (curtain side) on blowing vent. When the right corner cut thru into a unknown old mine, there was some water every-one evacuated no one was hurt and no equipment was damaged no ch4 or bad air was in old mine.","sourceDate":"2012-03-23"},{"SOURCE_ROW_NUMBER":"98388","DOCUMENT_NO":"220093200024","ACCIDENT_DT":"11/09/2009","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"After taking a cut right hand break out of the #7 entry the miner moved to another cut and the bolter operater seen the place was working and backed the bolter out and called for the boss and the place started working more and then fell starting from the inter into the right brk. they had just started the fall was approx. 8 ft wide, 4-5 ft thick and about 25 ft long.","sourceDate":"2009-11-09"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2018-08-02","lastDate":"2018-08-02","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":291,"firstDate":"2007-01-03","lastDate":"2014-11-25","metrics":{"ss":53,"delinquent":291,"recentRows":0,"paidPenalty":39551.71,"proposedPenalty":54043,"currentAssessment":54043},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1869667","VIOLATION_NO":"9020196","ISSUE_DT":"11/25/2014","CFR_STANDARD_CD":"70.100(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-11-25"},{"SOURCE_ROW_NUMBER":"1869666","VIOLATION_NO":"9020190","ISSUE_DT":"11/21/2014","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"108.00","CURRENT_ASSESSMENT_AMT":"108.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-11-21"},{"SOURCE_ROW_NUMBER":"1869649","VIOLATION_NO":"9020187","ISSUE_DT":"11/05/2014","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2000.00","CURRENT_ASSESSMENT_AMT":"2000.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-11-05"},{"SOURCE_ROW_NUMBER":"1869648","VIOLATION_NO":"9020186","ISSUE_DT":"11/05/2014","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"162.00","CURRENT_ASSESSMENT_AMT":"162.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-11-05"},{"SOURCE_ROW_NUMBER":"1869647","VIOLATION_NO":"9020185","ISSUE_DT":"11/05/2014","CFR_STANDARD_CD":"77.1606(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"243.00","CURRENT_ASSESSMENT_AMT":"243.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-11-05"},{"SOURCE_ROW_NUMBER":"1869646","VIOLATION_NO":"9020184","ISSUE_DT":"11/05/2014","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"243.00","CURRENT_ASSESSMENT_AMT":"243.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-11-05"},{"SOURCE_ROW_NUMBER":"1869645","VIOLATION_NO":"9020183","ISSUE_DT":"10/30/2014","CFR_STANDARD_CD":"77.502-2","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"285.00","CURRENT_ASSESSMENT_AMT":"285.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-10-30"},{"SOURCE_ROW_NUMBER":"1869644","VIOLATION_NO":"9020182","ISSUE_DT":"10/30/2014","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"176.00","CURRENT_ASSESSMENT_AMT":"176.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-10-30"},{"SOURCE_ROW_NUMBER":"1853313","VIOLATION_NO":"9018848","ISSUE_DT":"09/15/2014","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-09-15"},{"SOURCE_ROW_NUMBER":"1853312","VIOLATION_NO":"9018847","ISSUE_DT":"09/15/2014","CFR_STANDARD_CD":"75.310(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-09-15"},{"SOURCE_ROW_NUMBER":"1853310","VIOLATION_NO":"9018845","ISSUE_DT":"09/11/2014","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-09-11"},{"SOURCE_ROW_NUMBER":"1853309","VIOLATION_NO":"9018844","ISSUE_DT":"09/11/2014","CFR_STANDARD_CD":"75.364(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-09-11"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":321,"firstDate":"2007-06-05","lastDate":"2015-01-16","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":44,"validSamples":277,"maxConcentration":8.957,"concentrationTotal":184.956},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"995008","CASS_NUM":"51345897","SMP_TAKEN_DT":"1/16/2015","CONC":".014","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"CONTROL FILTER ABSENT","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-01-16"},{"SOURCE_ROW_NUMBER":"1509766","CASS_NUM":"51345880","SMP_TAKEN_DT":"1/15/2015","CONC":"1.562","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"CONTROL FILTER ABSENT","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-01-15"},{"SOURCE_ROW_NUMBER":"1247693","CASS_NUM":"51345884","SMP_TAKEN_DT":"1/14/2015","CONC":".044","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"CONTROL FILTER ABSENT","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-01-14"},{"SOURCE_ROW_NUMBER":"1248970","CASS_NUM":"51345862","SMP_TAKEN_DT":"1/13/2015","CONC":".277","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"CONTROL FILTER ABSENT","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-01-13"},{"SOURCE_ROW_NUMBER":"700646","CASS_NUM":"51345853","SMP_TAKEN_DT":"1/13/2015","CONC":".257","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"CONTROL FILTER ABSENT","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-01-13"},{"SOURCE_ROW_NUMBER":"1430516","CASS_NUM":"51308460","SMP_TAKEN_DT":"1/12/2015","CONC":".149","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"CONTROL FILTER ABSENT","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-01-12"},{"SOURCE_ROW_NUMBER":"1286692","CASS_NUM":"51345849","SMP_TAKEN_DT":"1/12/2015","CONC":".672","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"CONTROL FILTER ABSENT","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-01-12"},{"SOURCE_ROW_NUMBER":"1639962","CASS_NUM":"51345857","SMP_TAKEN_DT":"1/7/2015","CONC":".586","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"CONTROL FILTER ABSENT","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-01-07"},{"SOURCE_ROW_NUMBER":"653715","CASS_NUM":"51308465","SMP_TAKEN_DT":"1/6/2015","CONC":".234","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"CONTROL FILTER ABSENT","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-01-06"},{"SOURCE_ROW_NUMBER":"1300488","CASS_NUM":"51306057","SMP_TAKEN_DT":"1/5/2015","CONC":".294","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"CONTROL FILTER ABSENT","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-01-05"},{"SOURCE_ROW_NUMBER":"1421937","CASS_NUM":"58171312","SMP_TAKEN_DT":"11/4/2014","CONC":".129","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-11-04"},{"SOURCE_ROW_NUMBER":"1359964","CASS_NUM":"58171323","SMP_TAKEN_DT":"11/4/2014","CONC":".091","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"TRACTOR OPERATOR/MOTORMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-11-04"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":75,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":20,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"2002-02-15","lastDate":"2006-04-12","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":63,"firstDate":"2006-07-25","lastDate":"2015-06-08","metrics":{"inspectors":113,"recentRows":0,"onSiteHours":1355.5,"inspectionHours":2595.75,"inspectionSamples":436},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"41298","EVENT_NO":"6304537","INSPECTION_BEGIN_DT":"06/08/2015","INSPECTION_END_DT":"06/18/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2015-06-08"},{"SOURCE_ROW_NUMBER":"36739","EVENT_NO":"6305193","INSPECTION_BEGIN_DT":"02/02/2015","INSPECTION_END_DT":"02/02/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"22","SUM_TOTAL_ON_SITE_HOURS":"11","sourceDate":"2015-02-02"},{"SOURCE_ROW_NUMBER":"395647","EVENT_NO":"6305961","INSPECTION_BEGIN_DT":"01/27/2015","INSPECTION_END_DT":"01/27/2015","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4.25","sourceDate":"2015-01-27"},{"SOURCE_ROW_NUMBER":"1028107","EVENT_NO":"6305183","INSPECTION_BEGIN_DT":"12/16/2014","INSPECTION_END_DT":"12/16/2014","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2014-12-16"},{"SOURCE_ROW_NUMBER":"907862","EVENT_NO":"6304529","INSPECTION_BEGIN_DT":"11/21/2014","INSPECTION_END_DT":"01/22/2015","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"20.5","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2014-11-21"},{"SOURCE_ROW_NUMBER":"1152276","EVENT_NO":"6304527","INSPECTION_BEGIN_DT":"10/21/2014","INSPECTION_END_DT":"11/17/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"103.5","SUM_TOTAL_ON_SITE_HOURS":"54.25","sourceDate":"2014-10-21"},{"SOURCE_ROW_NUMBER":"873541","EVENT_NO":"6305171","INSPECTION_BEGIN_DT":"10/09/2014","INSPECTION_END_DT":"10/09/2014","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"15","SUM_TOTAL_ON_SITE_HOURS":"8.5","sourceDate":"2014-10-09"},{"SOURCE_ROW_NUMBER":"725119","EVENT_NO":"6305166","INSPECTION_BEGIN_DT":"09/24/2014","INSPECTION_END_DT":"09/24/2014","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"20.5","SUM_TOTAL_ON_SITE_HOURS":"11","sourceDate":"2014-09-24"},{"SOURCE_ROW_NUMBER":"1053874","EVENT_NO":"6300938","INSPECTION_BEGIN_DT":"09/09/2014","INSPECTION_END_DT":"09/16/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"44.5","SUM_TOTAL_ON_SITE_HOURS":"23.5","sourceDate":"2014-09-09"},{"SOURCE_ROW_NUMBER":"350298","EVENT_NO":"6305041","INSPECTION_BEGIN_DT":"09/02/2014","INSPECTION_END_DT":"09/02/2014","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2014-09-02"},{"SOURCE_ROW_NUMBER":"112960","EVENT_NO":"6305157","INSPECTION_BEGIN_DT":"08/12/2014","INSPECTION_END_DT":"08/12/2014","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"17","SUM_TOTAL_ON_SITE_HOURS":"8.5","sourceDate":"2014-08-12"},{"SOURCE_ROW_NUMBER":"577936","EVENT_NO":"6305034","INSPECTION_BEGIN_DT":"07/30/2014","INSPECTION_END_DT":"07/30/2014","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2014-07-30"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":78,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2015-Q4":{"hours":0,"employees":0,"production":0},"2015-Q3":{"hours":0,"employees":0,"production":0},"2015-Q2":{"hours":0,"employees":0,"production":0},"2015-Q1":{"hours":2289,"employees":11,"production":657},"2014-Q4":{"hours":4996,"employees":12,"production":5628},"2014-Q3":{"hours":4956,"employees":10,"production":7493},"2014-Q2":{"hours":5254,"employees":10,"production":6019},"2014-Q1":{"hours":4717,"employees":10,"production":7029},"2013-Q4":{"hours":5233,"employees":10,"production":6512},"2013-Q3":{"hours":5062,"employees":10,"production":6452},"2013-Q2":{"hours":4716,"employees":9,"production":4985},"2013-Q1":{"hours":4442,"employees":10,"production":4595}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":10,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2006":{"hours":420,"employees":4,"production":410},"2007":{"hours":1510,"employees":4,"production":2490},"2008":{"hours":4636,"employees":4,"production":5993},"2009":{"hours":9879,"employees":5,"production":19124},"2010":{"hours":13556,"employees":8,"production":22659},"2011":{"hours":8806,"employees":7,"production":18614},"2012":{"hours":18682,"employees":10,"production":28617},"2013":{"hours":19453,"employees":10,"production":22544},"2014":{"hours":19923,"employees":11,"production":26169},"2015":{"hours":2289,"employees":11,"production":657}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":28,"firstDate":"2009-07-14","lastDate":"2014-09-11","metrics":{"recentRows":0,"doseOver100":1,"actDoseTotal":1510,"pelDoseTotal":1135},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"249382","EVENT_NO":"6300938","SURVEY_DATE":"09/11/2014","OCCUPATION_CD_DESC":"DISPATCHER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"12","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2014-09-11"},{"SOURCE_ROW_NUMBER":"249381","EVENT_NO":"6300929","SURVEY_DATE":"04/16/2014","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"6","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2014-04-16"},{"SOURCE_ROW_NUMBER":"249380","EVENT_NO":"6300929","SURVEY_DATE":"04/16/2014","OCCUPATION_CD_DESC":"TRACTOR OPERATOR/MOTORMAN","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"39","PEL_DOSE_90":"35","SURVEY_TYPE":"I","sourceDate":"2014-04-16"},{"SOURCE_ROW_NUMBER":"249379","EVENT_NO":"6300929","SURVEY_DATE":"04/16/2014","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"14","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2014-04-16"},{"SOURCE_ROW_NUMBER":"249378","EVENT_NO":"6300929","SURVEY_DATE":"04/16/2014","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"066","ACT_DOSE_85":"73","PEL_DOSE_90":"65","SURVEY_TYPE":"I","sourceDate":"2014-04-16"},{"SOURCE_ROW_NUMBER":"249377","EVENT_NO":"6300929","SURVEY_DATE":"04/16/2014","OCCUPATION_CD_DESC":"TRACTOR OPERATOR/MOTORMAN","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"38","PEL_DOSE_90":"34","SURVEY_TYPE":"I","sourceDate":"2014-04-16"},{"SOURCE_ROW_NUMBER":"249368","EVENT_NO":"6293293","SURVEY_DATE":"10/22/2012","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"83","PEL_DOSE_90":"71","SURVEY_TYPE":"I","sourceDate":"2012-10-22"},{"SOURCE_ROW_NUMBER":"249367","EVENT_NO":"6293293","SURVEY_DATE":"10/22/2012","OCCUPATION_CD_DESC":"TRACTOR OPERATOR/MOTORMAN","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"57","PEL_DOSE_90":"32","SURVEY_TYPE":"I","sourceDate":"2012-10-22"},{"SOURCE_ROW_NUMBER":"249366","EVENT_NO":"6293293","SURVEY_DATE":"10/22/2012","OCCUPATION_CD_DESC":"TRACTOR OPERATOR/MOTORMAN","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"120","PEL_DOSE_90":"96","SURVEY_TYPE":"I","sourceDate":"2012-10-22"},{"SOURCE_ROW_NUMBER":"249365","EVENT_NO":"6293293","SURVEY_DATE":"10/22/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"043","ACT_DOSE_85":"55","PEL_DOSE_90":"34","SURVEY_TYPE":"I","sourceDate":"2012-10-22"},{"SOURCE_ROW_NUMBER":"249364","EVENT_NO":"6293293","SURVEY_DATE":"10/22/2012","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"066","ACT_DOSE_85":"89","PEL_DOSE_90":"73","SURVEY_TYPE":"I","sourceDate":"2012-10-22"},{"SOURCE_ROW_NUMBER":"249376","EVENT_NO":"6296360","SURVEY_DATE":"03/02/2012","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"066","ACT_DOSE_85":"56","PEL_DOSE_90":"27","SURVEY_TYPE":"I","sourceDate":"2012-03-02"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":12,"firstDate":"2008-06-11","lastDate":"2014-11-04","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":9.3,"validSamples":12,"quartzPctTotal":68.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"150914","CASSETTE_NO":"58171238","SAMPLE_DT":"11/04/2014","QUARTZ_PCT":"05.4","QUARTZ_MICROGRAMS":"138","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-11-04"},{"SOURCE_ROW_NUMBER":"9474","CASSETTE_NO":"58171008","SAMPLE_DT":"09/10/2014","QUARTZ_PCT":"04.2","QUARTZ_MICROGRAMS":"14","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-09-10"},{"SOURCE_ROW_NUMBER":"15370","CASSETTE_NO":"58132429","SAMPLE_DT":"01/14/2014","QUARTZ_PCT":"05.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-01-14"},{"SOURCE_ROW_NUMBER":"14954","CASSETTE_NO":"58007805","SAMPLE_DT":"07/11/2013","QUARTZ_PCT":"03.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-07-11"},{"SOURCE_ROW_NUMBER":"6768","CASSETTE_NO":"57994729","SAMPLE_DT":"02/27/2013","QUARTZ_PCT":"09.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-02-27"},{"SOURCE_ROW_NUMBER":"117036","CASSETTE_NO":"57983730","SAMPLE_DT":"10/11/2012","QUARTZ_PCT":"03.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-10-11"},{"SOURCE_ROW_NUMBER":"63202","CASSETTE_NO":"57963227","SAMPLE_DT":"06/11/2012","QUARTZ_PCT":"06.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-06-11"},{"SOURCE_ROW_NUMBER":"131324","CASSETTE_NO":"57902605","SAMPLE_DT":"09/16/2011","QUARTZ_PCT":"06.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-09-16"},{"SOURCE_ROW_NUMBER":"90711","CASSETTE_NO":"57723806","SAMPLE_DT":"07/15/2009","QUARTZ_PCT":"05.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-07-15"},{"SOURCE_ROW_NUMBER":"119560","CASSETTE_NO":"57723833","SAMPLE_DT":"06/24/2009","QUARTZ_PCT":"06.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-06-24"},{"SOURCE_ROW_NUMBER":"70047","CASSETTE_NO":"57691312","SAMPLE_DT":"02/25/2009","QUARTZ_PCT":"06.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-02-25"},{"SOURCE_ROW_NUMBER":"33836","CASSETTE_NO":"57732038","SAMPLE_DT":"06/11/2008","QUARTZ_PCT":"06.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-06-11"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":296,"firstDate":"2007-01-03","lastDate":"2014-11-25","metrics":{"ss":53,"amountDue":54043,"contested":0,"amountPaid":39551.71,"recentRows":0,"section104d":1,"unterminated":2,"proposedPenalty":54043},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2833830","VIOLATION_NO":"9020196","VIOLATION_ISSUE_DT":"11/25/2014","SIG_SUB":"N","PART_SECTION":"70.100(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/22/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2014-11-25"},{"SOURCE_ROW_NUMBER":"2833829","VIOLATION_NO":"9020190","VIOLATION_ISSUE_DT":"11/21/2014","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"6","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/02/2014","PROPOSED_PENALTY":"108","AMOUNT_DUE":"108","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2014-11-21"},{"SOURCE_ROW_NUMBER":"2833810","VIOLATION_NO":"9020187","VIOLATION_ISSUE_DT":"11/05/2014","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"11/05/2014","PROPOSED_PENALTY":"2000","AMOUNT_DUE":"2000","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2014-11-05"},{"SOURCE_ROW_NUMBER":"2833809","VIOLATION_NO":"9020186","VIOLATION_ISSUE_DT":"11/05/2014","SIG_SUB":"N","PART_SECTION":"75.1100-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"6","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/05/2014","PROPOSED_PENALTY":"162","AMOUNT_DUE":"162","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2014-11-05"},{"SOURCE_ROW_NUMBER":"2833808","VIOLATION_NO":"9020185","VIOLATION_ISSUE_DT":"11/05/2014","SIG_SUB":"Y","PART_SECTION":"77.1606(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/12/2014","PROPOSED_PENALTY":"243","AMOUNT_DUE":"243","AMOUNT_PAID":"243","CONTESTED_IND":"N","sourceDate":"2014-11-05"},{"SOURCE_ROW_NUMBER":"2833807","VIOLATION_NO":"9020184","VIOLATION_ISSUE_DT":"11/05/2014","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/12/2014","PROPOSED_PENALTY":"243","AMOUNT_DUE":"243","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2014-11-05"},{"SOURCE_ROW_NUMBER":"2833806","VIOLATION_NO":"9020183","VIOLATION_ISSUE_DT":"10/30/2014","SIG_SUB":"N","PART_SECTION":"77.502-2","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"10/30/2014","PROPOSED_PENALTY":"285","AMOUNT_DUE":"285","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2014-10-30"},{"SOURCE_ROW_NUMBER":"2833805","VIOLATION_NO":"9020182","VIOLATION_ISSUE_DT":"10/30/2014","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/30/2014","PROPOSED_PENALTY":"176","AMOUNT_DUE":"176","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2014-10-30"},{"SOURCE_ROW_NUMBER":"2833767","VIOLATION_NO":"9018848","VIOLATION_ISSUE_DT":"09/15/2014","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"NoNegligence","TERMINATION_DT":"09/15/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2014-09-15"},{"SOURCE_ROW_NUMBER":"2833766","VIOLATION_NO":"9018847","VIOLATION_ISSUE_DT":"09/15/2014","SIG_SUB":"N","PART_SECTION":"75.310(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/15/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2014-09-15"},{"SOURCE_ROW_NUMBER":"2833764","VIOLATION_NO":"9018845","VIOLATION_ISSUE_DT":"09/11/2014","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/11/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2014-09-11"},{"SOURCE_ROW_NUMBER":"2833763","VIOLATION_NO":"9018844","VIOLATION_ISSUE_DT":"09/11/2014","SIG_SUB":"N","PART_SECTION":"75.364(h)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/11/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2014-09-11"}]}],"safety":{"href":"/api/v1/mines/4608955/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4608955/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Respirable dust standards.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-70/subpart-B/section-70.100","part":"70","subchapter":"O","subpart":"B","id":"70.100","citation":"30 CFR 70.100","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 70—MANDATORY HEALTH STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.403","heading":"Maintenance of incombustible content of rock dust.","id":"75.403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 80 percent. Where methane is present in any ventilating current, the percent of incombustible content of such combined dust shall be increased 0.4 percent for each 0.1 percent of methane.\n\n[75 FR 57857, Sept. 23, 2010; 76 FR 35978, June 21, 2011]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1725","heading":"Machinery and equipment; operation and maintenance.","id":"75.1725","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1725","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-3","heading":"Condition and examination of firefighting equipment.","id":"75.1100-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"All firefighting equipment shall be maintained in a usable and operative condition. Chemical extinguishers shall be examined every 6 months and the date of the examination shall be written on a permanent tag attached to the extinguisher.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":1},{"chapter":"I","heading":"Electric equipment; frequency of examination and testing.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502-2","part":"77","subchapter":"O","subpart":"F","id":"77.502-2","citation":"30 CFR 77.502-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","heading":"Installation of main mine fans.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.310","part":"75","subchapter":"O","subpart":"D","id":"75.310","citation":"30 CFR 75.310","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.364","heading":"Weekly examination.","id":"75.364","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.364","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Worked-out areas. (1) At least every 7 days, a certified person shall examine unsealed worked-out areas where no pillars have been recovered by traveling to the area of deepest penetration; measuring methane and oxygen concentrations and air quantities and making tests to determine if the air is moving in the proper direction in the area. The locations of measurement points where tests and measurements will be performed shall be included in the mine ventilation plan and shall be adequate in number and location to assure ventilation and air quality in the area. Air quantity measurements shall also be made where the air enters and leaves the worked-out area. An alternative method of evaluating the ventilation of the area may be approved in the ventilation plan.\n\n(2) At least every 7 days, a certified person shall evaluate the effectiveness of bleeder systems required by § 75.334 as follows:\n\n(i) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in its proper direction shall be made where air enters the worked-out area.\n\n(ii) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in the proper direction shall be made immediately before the air enters a return split of air.\n\n(iii) At least one entry of each set of bleeder entries used as part of a bleeder system under § 75.334 shall be traveled in its entirety. Measurements of methane and oxygen concentrations and air quantities and a test to determine if the air is moving in the proper direction shall be made at the measurement point locations specified in the mine ventilation plan to determine the effectiveness of the bleeder system.\n\n(iv) In lieu of the requirements of paragraphs (a)(2)(i) and (iii) of this section, an alternative method of evaluation may be specified in the ventilation plan provided the alternative method results in proper evaluation of the effectiveness of the bleeder system.\n\n(b) Hazardous conditions and violations of mandatory health or safety standards. At least every 7 days, an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(8) of this section shall be made by a certified person designated by the operator at the following locations:\n\n(1) In at least one entry of each intake air course, in its entirety, so that the entire air course is traveled.\n\n(2) In at least one entry of each return air course, in its entirety, so that the entire air course is traveled.\n\n(3) In each longwall or shortwall travelway in its entirety, so that the entire travelway is traveled.\n\n(4) At each seal along return and bleeder air courses and at each seal along intake air courses not examined under § 75.360(b)(5).\n\n(5) In each escapeway so that the entire escapeway is traveled.\n\n(6) On each working section not examined under § 75.360(b)(3) during the previous 7 days.\n\n(7) At each water pump not examined during a preshift examination conducted during the previous 7 days.\n\n(8) Weekly examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust; and\n\n(iv) § 75.1403—maintenance of off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) Measurements and tests. At least every 7 days, a certified person shall—\n\n(1) Determine the volume of air entering the main intakes and in each intake split;\n\n(2) Determine the volume of air and test for methane in the last open crosscut in any pair or set of developing entries or rooms, in the return of each split of air immediately before it enters the main returns, and where the air leaves the main returns; and\n\n(3) Test for methane in the return entry nearest each set of seals immediately after the air passes the seals.\n\n(d) Hazardous conditions shall be corrected immediately. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Any violation of the nine mandatory health or safety standards found during a weekly examination shall be corrected.\n\n(e) The weekly examination may be conducted at the same time as the preshift or on-shift examinations.\n\n(f) (1) The weekly examination is not required during any 7 day period in which no one enters any underground area of the mine.\n\n(2) Except for certified persons required to make examinations, no one shall enter any underground area of the mine if a weekly examination has not been completed within the previous 7 days.\n\n(g) Certification. The person making the weekly examinations shall certify by initials, date, and the time that the examination was made. Certifications and times shall appear at enough locations to show that the entire area has been examined.\n\n(h) Recordkeeping. At the completion of any shift during which a portion of a weekly examination is conducted, a record of the results of each weekly examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards found during each examination and their locations, the corrective action taken, and the results and location of air and methane measurements, shall be made. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the person making the examination or a person designated by the operator. If made by a person other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(i) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 77 FR 20715, Apr. 6, 2012]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4608955","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}