{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4608933","name":"White Oak","status":"Abandoned and Sealed","status_date":"2012-05-16","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Boone","nearest_town":"Madison","operator_id":"P21654","operator_name":"Independence Coal Company Inc","controller_id":"0127923","controller_name":"Alpha Natural Resources Holdings, Inc","district":"C04","office":"Madison WV Field Office","employees":0,"latitude":38.030277,"longitude":-81.661944},"coverage":{"contributingSources":15,"registeredSources":20,"sourceRows":1094},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4608933","name":"White Oak"},"operator":{"type":"operator","id":"P21654","name":"Independence Coal Company Inc"},"controller":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"mine","id":"4608933","name":"White Oak"},"validFrom":"1950-01-01","validTo":"2011-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608933|C02508|1950-01-01|2011-05-31"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"mine","id":"4608933","name":"White Oak"},"validFrom":"1991-12-01","validTo":"2011-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608933|C02508|1991-12-01|2011-05-31"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P01231","name":"Omar Mining Company"},"object":{"type":"mine","id":"4608933","name":"White Oak"},"validFrom":"2001-12-11","validTo":"2002-01-23","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608933|P01231|2001-12-11|2002-01-23"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"P01231","name":"Omar Mining Company"},"validFrom":"2001-12-11","validTo":"2002-01-23","current":false,"derived":true,"evidenceMineId":"4608933","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608933|P01231|2001-12-11|C02508|1950-01-01|58828"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P21654","name":"Independence Coal Company Inc"},"object":{"type":"mine","id":"4608933","name":"White Oak"},"validFrom":"2002-01-24","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608933|P21654|2002-01-24|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"P21654","name":"Independence Coal Company Inc"},"validFrom":"2002-01-24","validTo":"2011-05-31","current":false,"derived":true,"evidenceMineId":"4608933","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608933|P21654|2002-01-24|C02508|1991-12-01|59286"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"4608933","name":"White Oak"},"validFrom":"2011-06-01","validTo":"2016-07-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608933|0041211|2011-06-01|2016-07-25"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P01231","name":"Omar Mining Company"},"validFrom":"2011-06-01","validTo":"2002-01-23","current":false,"derived":true,"evidenceMineId":"4608933","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608933|P01231|2001-12-11|0041211|2011-06-01|2161"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P21654","name":"Independence Coal Company Inc"},"validFrom":"2011-06-01","validTo":"2016-07-25","current":false,"derived":true,"evidenceMineId":"4608933","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608933|P21654|2002-01-24|0041211|2011-06-01|2162"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"mine","id":"4608933","name":"White Oak"},"validFrom":"2016-07-26","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608933|0127923|2016-07-26|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"operator","id":"P01231","name":"Omar Mining Company"},"validFrom":"2016-07-26","validTo":"2002-01-23","current":false,"derived":true,"evidenceMineId":"4608933","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608933|P01231|2001-12-11|0127923|2016-07-26|25605"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"operator","id":"P21654","name":"Independence Coal Company Inc"},"validFrom":"2016-07-26","validTo":null,"current":true,"derived":true,"evidenceMineId":"4608933","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608933|P21654|2002-01-24|0127923|2016-07-26|25606"}}],"coverage":{"historyRecords":6,"edgeCount":12,"intervalAnomalies":2,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":7,"firstDate":"2004-03-16","lastDate":"2005-08-18","metrics":{"daysLost":0,"injuries":3,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"55483","DOCUMENT_NO":"220052490123","ACCIDENT_DT":"08/18/2005","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Security guard, Watchman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was walking down mine office steps when his left boot tread caught on steps causing him to twist his left ankle.","sourceDate":"2005-08-18"},{"SOURCE_ROW_NUMBER":"81355","DOCUMENT_NO":"220050620020","ACCIDENT_DT":"02/25/2005","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"UNPLANNED ROOF FALL OCCURRED DURING THE MAINTENANCE SHIFT. THE LOCATION OF THE FALL WAS IN #10 ENTRY 2 BKS INBY SPAD #413 AND 30' FROM THE ACTIVE FACE. THE FALL MEASURED 30'X15'X5-6' AND FELL ON THE JOY 12-27 RIGHTCONTINUOUS MINER. THERE WERE NO INJURIES. VENTILATION WAS NOT AFFECTED. ROCK WAS REMOVED FROM THE CAR AND MINING CEASED IN THAT AREA OF THE MINE","sourceDate":"2005-02-25"},{"SOURCE_ROW_NUMBER":"231918","DOCUMENT_NO":"220050140060","ACCIDENT_DT":"01/06/2005","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"ON 1/6/05 WHILE OAK MINE EXPERIENCED AN UNPLANNED ROOF FALL. THE FALL MEASURED 30'X18'X6' AND WAS 3,400 FT FROM THE ACTIVE FACE. THE FALL WILL BE REHABILITATED.","sourceDate":"2005-01-06"},{"SOURCE_ROW_NUMBER":"128422","DOCUMENT_NO":"220050140046","ACCIDENT_DT":"01/06/2005","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"ON 1/6/05 WHITE OAK MINE EXPERIENCED AN UNPLANNED ROOF FALL. THE FALL MEASURED 23'X 16'X 5' AND WAS 3,200' FROM THE ACTIVE FACE. THE FALL WILL BE REHABILITATED.","sourceDate":"2005-01-06"},{"SOURCE_ROW_NUMBER":"266301","DOCUMENT_NO":"220042150056","ACCIDENT_DT":"07/28/2004","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was cutting a hole in the dust hose when he dropped his knife. He cut his left leg at the knee area. He received 4 stitches.","sourceDate":"2004-07-28"},{"SOURCE_ROW_NUMBER":"214734","DOCUMENT_NO":"220041100018","ACCIDENT_DT":"03/31/2004","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"AN UNPLANNED ROOF FALL OCURRED AT THE WHITE OAK MINE ON 3/31/04. THE FALL MEASURED 70'X 20'X 48\"-8'.","sourceDate":"2004-03-31"},{"SOURCE_ROW_NUMBER":"137155","DOCUMENT_NO":"220040840034","ACCIDENT_DT":"03/16/2004","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE was cleaning duct work on the right continuous miner. He raised the lid to reach for the waterhose. The lid fell cutting his right ring finger. He received four stitches.","sourceDate":"2004-03-16"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2012-05-16","lastDate":"2012-05-16","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":99,"firstDate":"2002-03-13","lastDate":"2006-01-05","metrics":{"ss":37,"delinquent":74,"recentRows":0,"paidPenalty":8987,"proposedPenalty":9047,"currentAssessment":9047},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"818754","VIOLATION_NO":"7245052","ISSUE_DT":"01/05/2006","CFR_STANDARD_CD":"77.512","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"350.00","CURRENT_ASSESSMENT_AMT":"350.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-01-05"},{"SOURCE_ROW_NUMBER":"804798","VIOLATION_NO":"7245031","ISSUE_DT":"12/06/2005","CFR_STANDARD_CD":"75.1712-3(c)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-12-06"},{"SOURCE_ROW_NUMBER":"804797","VIOLATION_NO":"7245030","ISSUE_DT":"11/22/2005","CFR_STANDARD_CD":"77.1102","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-11-22"},{"SOURCE_ROW_NUMBER":"804796","VIOLATION_NO":"7245029","ISSUE_DT":"11/22/2005","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-11-22"},{"SOURCE_ROW_NUMBER":"804795","VIOLATION_NO":"7245028","ISSUE_DT":"11/22/2005","CFR_STANDARD_CD":"77.900-2","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-11-22"},{"SOURCE_ROW_NUMBER":"804794","VIOLATION_NO":"7245027","ISSUE_DT":"11/22/2005","CFR_STANDARD_CD":"77.800-2","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-11-22"},{"SOURCE_ROW_NUMBER":"803793","VIOLATION_NO":"7242201","ISSUE_DT":"04/12/2005","CFR_STANDARD_CD":"77.509(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"228.00","CURRENT_ASSESSMENT_AMT":"228.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-04-12"},{"SOURCE_ROW_NUMBER":"803792","VIOLATION_NO":"7237240","ISSUE_DT":"04/12/2005","CFR_STANDARD_CD":"77.205(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"177.00","CURRENT_ASSESSMENT_AMT":"177.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-04-12"},{"SOURCE_ROW_NUMBER":"803791","VIOLATION_NO":"7237239","ISSUE_DT":"04/12/2005","CFR_STANDARD_CD":"75.333(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-04-12"},{"SOURCE_ROW_NUMBER":"803790","VIOLATION_NO":"7237238","ISSUE_DT":"04/12/2005","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"177.00","CURRENT_ASSESSMENT_AMT":"177.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-04-12"},{"SOURCE_ROW_NUMBER":"803789","VIOLATION_NO":"7237237","ISSUE_DT":"04/12/2005","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"254.00","CURRENT_ASSESSMENT_AMT":"254.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-04-12"},{"SOURCE_ROW_NUMBER":"803788","VIOLATION_NO":"7237234","ISSUE_DT":"04/07/2005","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"177.00","CURRENT_ASSESSMENT_AMT":"177.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-04-07"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":90,"firstDate":"2004-01-21","lastDate":"2005-03-22","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":15,"validSamples":75,"maxConcentration":2.173,"concentrationTotal":42.938},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"571014","CASS_NUM":"50774375","SMP_TAKEN_DT":"3/22/2005","CONC":"1.909","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-03-22"},{"SOURCE_ROW_NUMBER":"1255661","CASS_NUM":"50774322","SMP_TAKEN_DT":"3/17/2005","CONC":".421","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-03-17"},{"SOURCE_ROW_NUMBER":"403935","CASS_NUM":"50774369","SMP_TAKEN_DT":"3/17/2005","CONC":".94","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-03-17"},{"SOURCE_ROW_NUMBER":"829393","CASS_NUM":"50774301","SMP_TAKEN_DT":"3/16/2005","CONC":".61","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-03-16"},{"SOURCE_ROW_NUMBER":"824602","CASS_NUM":"50774316","SMP_TAKEN_DT":"3/16/2005","CONC":".632","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-03-16"},{"SOURCE_ROW_NUMBER":"601139","CASS_NUM":"50774366","SMP_TAKEN_DT":"3/15/2005","CONC":".714","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-03-15"},{"SOURCE_ROW_NUMBER":"301658","CASS_NUM":"50774307","SMP_TAKEN_DT":"3/4/2005","CONC":".139","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-03-04"},{"SOURCE_ROW_NUMBER":"1322622","CASS_NUM":"50774345","SMP_TAKEN_DT":"2/24/2005","CONC":".03","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-24"},{"SOURCE_ROW_NUMBER":"1249015","CASS_NUM":"50774325","SMP_TAKEN_DT":"2/24/2005","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INSUFFICIENT DUST OBSERVED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-24"},{"SOURCE_ROW_NUMBER":"946429","CASS_NUM":"50774377","SMP_TAKEN_DT":"2/23/2005","CONC":".024","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-23"},{"SOURCE_ROW_NUMBER":"1655348","CASS_NUM":"50774312","SMP_TAKEN_DT":"2/22/2005","CONC":".373","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-22"},{"SOURCE_ROW_NUMBER":"405304","CASS_NUM":"50774331","SMP_TAKEN_DT":"2/22/2005","CONC":".048","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-22"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":6,"firstDate":"2004-09-28","lastDate":"2006-02-06","metrics":{"linkedIssuances":6},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":598,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":107,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":6,"firstDate":"2001-12-11","lastDate":"2002-01-24","metrics":{"recentRows":0,"currentOperatorTenures":3,"completedOperatorTenures":3},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":39,"firstDate":"2002-02-05","lastDate":"2006-01-04","metrics":{"inspectors":50,"recentRows":0,"onSiteHours":551,"inspectionHours":903.75,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"623196","EVENT_NO":"4113412","INSPECTION_BEGIN_DT":"01/04/2006","INSPECTION_END_DT":"01/10/2006","ACTIVITY_CODE":"E24","ACTIVITY":"Other Technical Compliance Investigations","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2006-01-04"},{"SOURCE_ROW_NUMBER":"891308","EVENT_NO":"4113406","INSPECTION_BEGIN_DT":"12/30/2005","INSPECTION_END_DT":"02/07/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2005-12-30"},{"SOURCE_ROW_NUMBER":"244331","EVENT_NO":"4109597","INSPECTION_BEGIN_DT":"10/05/2005","INSPECTION_END_DT":"12/20/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"25","SUM_TOTAL_ON_SITE_HOURS":"12","sourceDate":"2005-10-05"},{"SOURCE_ROW_NUMBER":"678572","EVENT_NO":"4112808","INSPECTION_BEGIN_DT":"09/22/2005","INSPECTION_END_DT":"09/22/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2005-09-22"},{"SOURCE_ROW_NUMBER":"164911","EVENT_NO":"4109195","INSPECTION_BEGIN_DT":"04/05/2005","INSPECTION_END_DT":"06/06/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"81","SUM_TOTAL_ON_SITE_HOURS":"54","sourceDate":"2005-04-05"},{"SOURCE_ROW_NUMBER":"145556","EVENT_NO":"4110107","INSPECTION_BEGIN_DT":"02/28/2005","INSPECTION_END_DT":"03/03/2005","ACTIVITY_CODE":"AFC","ACTIVITY":"NON-INJURY ACCIDENT INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2005-02-28"},{"SOURCE_ROW_NUMBER":"1056032","EVENT_NO":"4109184","INSPECTION_BEGIN_DT":"01/19/2005","INSPECTION_END_DT":"03/15/2005","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"106.75","SUM_TOTAL_ON_SITE_HOURS":"74","sourceDate":"2005-01-19"},{"SOURCE_ROW_NUMBER":"605309","EVENT_NO":"4109961","INSPECTION_BEGIN_DT":"01/11/2005","INSPECTION_END_DT":"01/11/2005","ACTIVITY_CODE":"AFC","ACTIVITY":"NON-INJURY ACCIDENT INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2005-01-11"},{"SOURCE_ROW_NUMBER":"516474","EVENT_NO":"4109960","INSPECTION_BEGIN_DT":"01/11/2005","INSPECTION_END_DT":"01/11/2005","ACTIVITY_CODE":"AFC","ACTIVITY":"NON-INJURY ACCIDENT INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2005-01-11"},{"SOURCE_ROW_NUMBER":"802682","EVENT_NO":"4109183","INSPECTION_BEGIN_DT":"01/06/2005","INSPECTION_END_DT":"01/10/2005","ACTIVITY_CODE":"AFC","ACTIVITY":"NON-INJURY ACCIDENT INVESTIGATION","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2005-01-06"},{"SOURCE_ROW_NUMBER":"468242","EVENT_NO":"4107224","INSPECTION_BEGIN_DT":"12/14/2004","INSPECTION_END_DT":"12/22/2004","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"16.5","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2004-12-14"},{"SOURCE_ROW_NUMBER":"624446","EVENT_NO":"4109556","INSPECTION_BEGIN_DT":"10/20/2004","INSPECTION_END_DT":"10/20/2004","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2004-10-20"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":24,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2006-Q3":{"hours":0,"employees":0,"production":0},"2006-Q1":{"hours":0,"employees":0,"production":0},"2005-Q4":{"hours":0,"employees":0,"production":0},"2005-Q3":{"hours":0,"employees":0,"production":0},"2005-Q2":{"hours":3720,"employees":5,"production":13885},"2005-Q1":{"hours":5470,"employees":8,"production":125568},"2004-Q4":{"hours":3621,"employees":5,"production":86477},"2004-Q3":{"hours":1685,"employees":4,"production":50550},"2004-Q2":{"hours":17592,"employees":17,"production":72097},"2004-Q1":{"hours":14905,"employees":71,"production":79492},"2003-Q4":{"hours":2546,"employees":10,"production":5447},"2003-Q3":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":3,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2003":{"hours":2836,"employees":6,"production":5447},"2004":{"hours":37803,"employees":24,"production":288616},"2005":{"hours":9190,"employees":7,"production":139453}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":10,"firstDate":"2004-04-27","lastDate":"2004-10-20","metrics":{"recentRows":0,"doseOver100":5,"actDoseTotal":896,"pelDoseTotal":674},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"249034","EVENT_NO":"4109556","SURVEY_DATE":"10/20/2004","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"40","PEL_DOSE_90":"18","SURVEY_TYPE":"I","sourceDate":"2004-10-20"},{"SOURCE_ROW_NUMBER":"249033","EVENT_NO":"4109556","SURVEY_DATE":"10/20/2004","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"74","PEL_DOSE_90":"49","SURVEY_TYPE":"I","sourceDate":"2004-10-20"},{"SOURCE_ROW_NUMBER":"249032","EVENT_NO":"4109556","SURVEY_DATE":"10/20/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"90","PEL_DOSE_90":"60","SURVEY_TYPE":"I","sourceDate":"2004-10-20"},{"SOURCE_ROW_NUMBER":"249031","EVENT_NO":"4109556","SURVEY_DATE":"10/20/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"108","PEL_DOSE_90":"81","SURVEY_TYPE":"I","sourceDate":"2004-10-20"},{"SOURCE_ROW_NUMBER":"249030","EVENT_NO":"4109556","SURVEY_DATE":"10/20/2004","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"112","PEL_DOSE_90":"97","SURVEY_TYPE":"I","sourceDate":"2004-10-20"},{"SOURCE_ROW_NUMBER":"249029","EVENT_NO":"4107355","SURVEY_DATE":"04/27/2004","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"56","PEL_DOSE_90":"36","SURVEY_TYPE":"I","sourceDate":"2004-04-27"},{"SOURCE_ROW_NUMBER":"249028","EVENT_NO":"4107355","SURVEY_DATE":"04/27/2004","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"65","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2004-04-27"},{"SOURCE_ROW_NUMBER":"249027","EVENT_NO":"4107355","SURVEY_DATE":"04/27/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"108","PEL_DOSE_90":"77","SURVEY_TYPE":"I","sourceDate":"2004-04-27"},{"SOURCE_ROW_NUMBER":"249026","EVENT_NO":"4107355","SURVEY_DATE":"04/27/2004","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"129","PEL_DOSE_90":"116","SURVEY_TYPE":"I","sourceDate":"2004-04-27"},{"SOURCE_ROW_NUMBER":"249025","EVENT_NO":"4107355","SURVEY_DATE":"04/27/2004","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"114","PEL_DOSE_90":"96","SURVEY_TYPE":"I","sourceDate":"2004-04-27"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":2,"firstDate":"2004-04-19","lastDate":"2005-01-25","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":6.7,"validSamples":2,"quartzPctTotal":11.6},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"73528","CASSETTE_NO":"57502308","SAMPLE_DT":"01/25/2005","QUARTZ_PCT":"04.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-01-25"},{"SOURCE_ROW_NUMBER":"73352","CASSETTE_NO":"57465182","SAMPLE_DT":"04/19/2004","QUARTZ_PCT":"06.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-04-19"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":101,"firstDate":"2002-03-13","lastDate":"2006-01-05","metrics":{"ss":37,"amountDue":9047,"contested":0,"amountPaid":8987,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":9047},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2830718","VIOLATION_NO":"7245052","VIOLATION_ISSUE_DT":"01/05/2006","SIG_SUB":"Y","PART_SECTION":"77.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/06/2006","PROPOSED_PENALTY":"350","AMOUNT_DUE":"350","AMOUNT_PAID":"350","CONTESTED_IND":"N","sourceDate":"2006-01-05"},{"SOURCE_ROW_NUMBER":"2830698","VIOLATION_NO":"7245031","VIOLATION_ISSUE_DT":"12/06/2005","SIG_SUB":"N","PART_SECTION":"75.1712-3(c)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"3","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/07/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-12-06"},{"SOURCE_ROW_NUMBER":"2830697","VIOLATION_NO":"7245030","VIOLATION_ISSUE_DT":"11/22/2005","SIG_SUB":"N","PART_SECTION":"77.1102","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/23/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-11-22"},{"SOURCE_ROW_NUMBER":"2830696","VIOLATION_NO":"7245029","VIOLATION_ISSUE_DT":"11/22/2005","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/23/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-11-22"},{"SOURCE_ROW_NUMBER":"2830695","VIOLATION_NO":"7245028","VIOLATION_ISSUE_DT":"11/22/2005","SIG_SUB":"N","PART_SECTION":"77.900-2","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/23/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-11-22"},{"SOURCE_ROW_NUMBER":"2830694","VIOLATION_NO":"7245027","VIOLATION_ISSUE_DT":"11/22/2005","SIG_SUB":"N","PART_SECTION":"77.800-2","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/23/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-11-22"},{"SOURCE_ROW_NUMBER":"2830672","VIOLATION_NO":"7242201","VIOLATION_ISSUE_DT":"04/12/2005","SIG_SUB":"Y","PART_SECTION":"77.509(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/12/2005","PROPOSED_PENALTY":"228","AMOUNT_DUE":"228","AMOUNT_PAID":"228","CONTESTED_IND":"N","sourceDate":"2005-04-12"},{"SOURCE_ROW_NUMBER":"2830671","VIOLATION_NO":"7237240","VIOLATION_ISSUE_DT":"04/12/2005","SIG_SUB":"Y","PART_SECTION":"77.205(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/12/2005","PROPOSED_PENALTY":"177","AMOUNT_DUE":"177","AMOUNT_PAID":"177","CONTESTED_IND":"N","sourceDate":"2005-04-12"},{"SOURCE_ROW_NUMBER":"2830670","VIOLATION_NO":"7237239","VIOLATION_ISSUE_DT":"04/12/2005","SIG_SUB":"N","PART_SECTION":"75.333(h)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/13/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-04-12"},{"SOURCE_ROW_NUMBER":"2830669","VIOLATION_NO":"7237238","VIOLATION_ISSUE_DT":"04/12/2005","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/13/2005","PROPOSED_PENALTY":"177","AMOUNT_DUE":"177","AMOUNT_PAID":"177","CONTESTED_IND":"N","sourceDate":"2005-04-12"},{"SOURCE_ROW_NUMBER":"2830668","VIOLATION_NO":"7237237","VIOLATION_ISSUE_DT":"04/12/2005","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/13/2005","PROPOSED_PENALTY":"254","AMOUNT_DUE":"254","AMOUNT_PAID":"254","CONTESTED_IND":"N","sourceDate":"2005-04-12"},{"SOURCE_ROW_NUMBER":"2830667","VIOLATION_NO":"7237236","VIOLATION_ISSUE_DT":"04/12/2005","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"04/13/2005","CONTESTED_IND":"N","sourceDate":"2005-04-12"}]}],"safety":{"href":"/api/v1/mines/4608933/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4608933/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.512","heading":"Inspection and cover plates.","id":"77.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.512","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Inspection and cover plates on electrical equipment shall be kept in place at all times except during testing or repairs.","occurrenceCount":1},{"chapter":"I","heading":"Minimum requirements of surface bathing facilities, change rooms, and sanitary toilet facilities.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1712-3","part":"75","subchapter":"O","subpart":"R","id":"75.1712-3","citation":"30 CFR 75.1712-3","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Warning signs; smoking and open flame.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1102","part":"77","subchapter":"O","subpart":"L","id":"77.1102","citation":"30 CFR 77.1102","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":1},{"chapter":"I","heading":"Testing, examination, and maintenance of circuit breakers; record.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-J/section-77.900-2","part":"77","subchapter":"O","subpart":"J","id":"77.900-2","citation":"30 CFR 77.900-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Testing, examination, and maintenance of circuit breakers; record.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-I/section-77.800-2","part":"77","subchapter":"O","subpart":"I","id":"77.800-2","citation":"30 CFR 77.800-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Transformers; installation and guarding.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.509","part":"77","subchapter":"O","subpart":"F","id":"77.509","citation":"30 CFR 77.509","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.205","heading":"Travelways at surface installations.","id":"77.205","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.205","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Safe means of access shall be provided and maintained to all working places.\n\n(b) Travelways and platforms or other means of access to areas where persons are required to travel or work, shall be kept clear of all extraneous material and other stumbling or slipping hazards.\n\n(c) Inclined travelways shall be constructed of nonskid material or equipped with cleats.\n\n(d) Regularly used travelways shall be sanded, salted, or cleared of snow and ice as soon as practicable.\n\n(e) Crossovers, elevated walkways, elevated ramps, and stairways shall be of substantial construction, provided with handrails, and maintained in good condition. Where necessary toeboards shall be provided.\n\n(f) Crossovers shall be provided where it is necessary to cross conveyors.\n\n(g) Moving conveyors shall be crossed only at designated crossover points.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":2}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4608933","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}