{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"4608928","name":"Fairmont Energy Mine #2","status":"Abandoned and Sealed","status_date":"2005-09-22","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Barbour","nearest_town":"VOLGA","operator_id":"P24513","operator_name":"Bishoff Brothers Inc.","controller_id":"C15986","controller_name":"Johnny J  Bishoff; James R  Bishoff","district":"C03","office":"Bridgeport WV Field Office","employees":0,"latitude":39.126666,"longitude":-80.166666},"coverage":{"contributingSources":14,"registeredSources":20,"sourceRows":1098},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4608928","name":"Fairmont Energy Mine #2"},"operator":{"type":"operator","id":"P24513","name":"Bishoff Brothers Inc."},"controller":{"type":"controller","id":"C15986","name":"Johnny J  Bishoff; James R  Bishoff"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C01017","name":"William E  Konya et al"},"object":{"type":"mine","id":"4608928","name":"Fairmont Energy Mine #2"},"validFrom":"1998-09-02","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608928|C01017|1998-09-02|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15986","name":"Johnny J  Bishoff et al"},"object":{"type":"mine","id":"4608928","name":"Fairmont Energy Mine #2"},"validFrom":"2001-01-04","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608928|C15986|2001-01-04|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24031","name":"Konya Enterprises, Inc."},"object":{"type":"mine","id":"4608928","name":"Fairmont Energy Mine #2"},"validFrom":"2001-11-12","validTo":"2002-01-19","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608928|P24031|2001-11-12|2002-01-19"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C01017","name":"William E  Konya et al"},"object":{"type":"operator","id":"P24031","name":"Konya Enterprises, Inc."},"validFrom":"2001-11-12","validTo":"2002-01-19","current":false,"derived":true,"evidenceMineId":"4608928","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608928|P24031|2001-11-12|C01017|1998-09-02|51776"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C01017","name":"Steve A  Konya et al"},"object":{"type":"operator","id":"P24031","name":"Konya Enterprises, Inc."},"validFrom":"2001-11-12","validTo":"2002-01-19","current":false,"derived":true,"evidenceMineId":"4608928","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608928|P24031|2001-11-12|C01017|1998-09-02|51777"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0050327","name":"TWOINONE COAL COMPANY, INC."},"object":{"type":"mine","id":"4608928","name":"Fairmont Energy Mine #2"},"validFrom":"2002-01-20","validTo":"2002-03-17","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608928|0050327|2002-01-20|2002-03-17"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15334","name":"Gary  Morgan"},"object":{"type":"mine","id":"4608928","name":"Fairmont Energy Mine #2"},"validFrom":"2002-01-20","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608928|C15334|2002-01-20|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15334","name":"Gary  Morgan"},"object":{"type":"operator","id":"0050327","name":"TWOINONE COAL COMPANY, INC."},"validFrom":"2002-01-20","validTo":"2002-03-17","current":false,"derived":true,"evidenceMineId":"4608928","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608928|0050327|2002-01-20|C15334|2002-01-20|95338"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24513","name":"Bishoff Brothers Inc."},"object":{"type":"mine","id":"4608928","name":"Fairmont Energy Mine #2"},"validFrom":"2002-03-18","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608928|P24513|2002-03-18|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15986","name":"Johnny J  Bishoff et al"},"object":{"type":"operator","id":"P24513","name":"Bishoff Brothers Inc."},"validFrom":"2002-03-18","validTo":null,"current":true,"derived":true,"evidenceMineId":"4608928","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608928|P24513|2002-03-18|C15986|2001-01-04|97940"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15986","name":"James R  Bishoff et al"},"object":{"type":"operator","id":"P24513","name":"Bishoff Brothers Inc."},"validFrom":"2002-03-18","validTo":null,"current":true,"derived":true,"evidenceMineId":"4608928","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608928|P24513|2002-03-18|C15986|2001-01-04|97941"}}],"coverage":{"historyRecords":5,"edgeCount":11,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":22,"firstDate":"2002-04-08","lastDate":"2005-06-20","metrics":{"daysLost":259,"injuries":11,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"63997","DOCUMENT_NO":"220051920058","ACCIDENT_DT":"06/20/2005","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A ROOF FALL WAS FOUND BY THE PRE-SHIFT MINE EXAMINER ON 6-20-05. THE LOCATION WAS 1 BLOCK INBY SPAD 31, IN #2 ENTRY. THE FALL OCCURRED OVER A WEEKEND. THE WIDTH 16', LENGTH 65', HEIGHT 6' TO 7'. DATE OF DEVELOPMENT 8-02. ROOF SUPPORT 6' FULLY GROUTED RESIN BOLTS WITH STRAPS. IN A 4 WAY INTERSECTION. THE FALL WILL NOT BE CLEANED UP.","sourceDate":"2005-06-20"},{"SOURCE_ROW_NUMBER":"223281","DOCUMENT_NO":"220051430078","ACCIDENT_DT":"05/09/2005","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE was taking a belt pin out using two hammers. When he hit one hammer against the other a piece of hammer (steel) came off and went into his left hand above the thumb.","sourceDate":"2005-05-09"},{"SOURCE_ROW_NUMBER":"154472","DOCUMENT_NO":"220051450051","ACCIDENT_DT":"03/02/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"5","NARRATIVE":"EE WAS MOVING CABLES.  HIS RIGHT LEG GOT CAUGHT IN THE MUD.  WHEN HE PULLED HIS LEG OUT OF THE MUD HE SPRAINED HIS RIGHT KNEE.  ON 5/2/05 HE HAD TO HAVE SURGERY ON HIS RIGHT KNEE.","sourceDate":"2005-03-02"},{"SOURCE_ROW_NUMBER":"63996","DOCUMENT_NO":"220043620044","ACCIDENT_DT":"09/22/2004","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A PILLAR FALL OCCURRED WHILE BACKING THE CONTINUOUS MINER OUT OF THE SECOND PILLAR SPLIT OF THE NO.10 PILLAR BLOCK, COVERING UP THE HEAD OF THE MINER. THE LENGTH, WIDTH & THICKNESS COULD NOT BE DETERMINED. THE FALL WAS IN THE NO. 10 ENTRY, 3 BLOCKS INBY STATION NO.219.","sourceDate":"2004-09-22"},{"SOURCE_ROW_NUMBER":"193128","DOCUMENT_NO":"220041800125","ACCIDENT_DT":"06/14/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between two or more moving objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"79","NARRATIVE":"EMPLOYEE WAS OPERATING THE FLETCHER ROOF BOLTER. WHILE BACKING UP TO GO INTO ANOTHER FACE, HE PINCHED HIS RIGHT LEG AND FOOT BETWEEN THE ROOF BOLTER AND THE JOY SHUTTLE CAR. HE WAS IN THE DECK OF THE BOLTER WITH HIS RIGHT LEG ON THE BUMPER.","sourceDate":"2004-06-14"},{"SOURCE_ROW_NUMBER":"193127","DOCUMENT_NO":"220041760052","ACCIDENT_DT":"06/09/2004","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall was found at 11:00 am on 6-9-04 in an idle entry 001 north mains. The fall will not be cleaned up. It was 18' wide 45' long 8' high. fully grouted resin bolts with 11' straps.","sourceDate":"2004-06-09"},{"SOURCE_ROW_NUMBER":"106832","DOCUMENT_NO":"220041800129","ACCIDENT_DT":"06/02/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"EMPLOYEE WAS WALKING BY THE POWER CENTER OF THE SECTION.  HE SLIPPED ON THE BELT MAT AT THE POWER CENTER, SPRAINING HIS RIGHT KNEE.  HE DID NOT GO TO THE DOCTOR UNTIL 6/11/04.","sourceDate":"2004-06-02"},{"SOURCE_ROW_NUMBER":"111241","DOCUMENT_NO":"220040300030","ACCIDENT_DT":"01/14/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"155","NARRATIVE":"EE WAS STEPPING INTO THE SCOOP BUCKET TO HOOK UP A CHAIN WHEN HE PULLED HIS LEFT KNEE.","sourceDate":"2004-01-14"},{"SOURCE_ROW_NUMBER":"270591","DOCUMENT_NO":"220040330088","ACCIDENT_DT":"01/12/2004","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A ROOF FALL WAS FOUND ON #1 BELTLINE AT SPAD NO. 14 IN A 4-WAY INTERSECTION. IT WAS 18 FT WIDE, 26 FT LONG, 10 FT HIGH. THE ROOF SUPPORT IN THIS AREA WAS 6' FULLY GROUTED RESIN BOLTS WITH CROS SBARS. DATE DEVELOPED WAS MAY 2002.","sourceDate":"2004-01-12"},{"SOURCE_ROW_NUMBER":"262138","DOCUMENT_NO":"220032600009","ACCIDENT_DT":"09/03/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"EE WAS REPAIRING THE CONVEYOR CHAINS ON THE MINER, WHEN HE HIT HIS LIFT FOOT WITH A SLEDGE HAMMER.","sourceDate":"2003-09-03"},{"SOURCE_ROW_NUMBER":"197370","DOCUMENT_NO":"220031740034","ACCIDENT_DT":"06/05/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"EE BENT OVER TO MOVE THE MINER CABLE OUT OF THE SHUTTLE CAR ROADWAY, WHEN HE PICKED THE CABLE UP HE PULLED A MUSCLE IN HIS LOWER BACK.","sourceDate":"2003-06-05"},{"SOURCE_ROW_NUMBER":"262137","DOCUMENT_NO":"220031570014","ACCIDENT_DT":"05/12/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"EE WAS CHECKING A HYD. HOSE THAT HE HAD TIGHTENED ON THE 488 S&S SCOOP. HE HAD TO BEND OVER AND LOOK INSIDE TO SEE IF IT WAS LEAKING. WHEN HE TURNED THE SCOOP ON AND PUSHED THE LEVER A HYD. HO SE BESIDE IT BLEW UP IN HIS FACE, AND GOT DIRT AND METAL IN HIS LEFT AND RIGHT EYES.","sourceDate":"2003-05-12"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2005-09-22","lastDate":"2005-09-22","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":175,"firstDate":"2002-04-30","lastDate":"2005-05-26","metrics":{"ss":63,"delinquent":175,"recentRows":0,"paidPenalty":974.49,"proposedPenalty":18797,"currentAssessment":18797},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"713276","VIOLATION_NO":"7097832","ISSUE_DT":"05/26/2005","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"154.00","CURRENT_ASSESSMENT_AMT":"154.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-05-26"},{"SOURCE_ROW_NUMBER":"713275","VIOLATION_NO":"7097831","ISSUE_DT":"05/26/2005","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-05-26"},{"SOURCE_ROW_NUMBER":"713274","VIOLATION_NO":"7097829","ISSUE_DT":"05/24/2005","CFR_STANDARD_CD":"75.1107-16(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-05-24"},{"SOURCE_ROW_NUMBER":"713273","VIOLATION_NO":"7097828","ISSUE_DT":"05/24/2005","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-05-24"},{"SOURCE_ROW_NUMBER":"713272","VIOLATION_NO":"7097822","ISSUE_DT":"05/16/2005","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"154.00","CURRENT_ASSESSMENT_AMT":"154.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-05-16"},{"SOURCE_ROW_NUMBER":"713271","VIOLATION_NO":"7097820","ISSUE_DT":"05/16/2005","CFR_STANDARD_CD":"70.207(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-05-16"},{"SOURCE_ROW_NUMBER":"713270","VIOLATION_NO":"7097819","ISSUE_DT":"05/12/2005","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"154.00","CURRENT_ASSESSMENT_AMT":"154.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-05-12"},{"SOURCE_ROW_NUMBER":"713269","VIOLATION_NO":"7097818","ISSUE_DT":"05/12/2005","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-05-12"},{"SOURCE_ROW_NUMBER":"713268","VIOLATION_NO":"7097816","ISSUE_DT":"05/11/2005","CFR_STANDARD_CD":"77.200","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"154.00","CURRENT_ASSESSMENT_AMT":"154.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-05-11"},{"SOURCE_ROW_NUMBER":"713267","VIOLATION_NO":"7097815","ISSUE_DT":"05/11/2005","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"437.00","CURRENT_ASSESSMENT_AMT":"437.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-05-11"},{"SOURCE_ROW_NUMBER":"713266","VIOLATION_NO":"7097814","ISSUE_DT":"05/11/2005","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"154.00","CURRENT_ASSESSMENT_AMT":"154.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-05-11"},{"SOURCE_ROW_NUMBER":"713265","VIOLATION_NO":"7097813","ISSUE_DT":"05/11/2005","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"154.00","CURRENT_ASSESSMENT_AMT":"154.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-05-11"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":211,"firstDate":"2002-05-20","lastDate":"2005-05-16","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":24,"validSamples":187,"maxConcentration":2.991,"concentrationTotal":129.493},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1434506","CASS_NUM":"57507180","SMP_TAKEN_DT":"5/16/2005","CONC":".039","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-16"},{"SOURCE_ROW_NUMBER":"1109245","CASS_NUM":"57507202","SMP_TAKEN_DT":"5/16/2005","CONC":".624","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-16"},{"SOURCE_ROW_NUMBER":"957182","CASS_NUM":"57507212","SMP_TAKEN_DT":"5/16/2005","CONC":".053","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-16"},{"SOURCE_ROW_NUMBER":"656046","CASS_NUM":"57507211","SMP_TAKEN_DT":"5/16/2005","CONC":"1.202","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-16"},{"SOURCE_ROW_NUMBER":"583031","CASS_NUM":"57507230","SMP_TAKEN_DT":"5/16/2005","CONC":".497","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-16"},{"SOURCE_ROW_NUMBER":"399243","CASS_NUM":"57507235","SMP_TAKEN_DT":"5/16/2005","CONC":".562","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-16"},{"SOURCE_ROW_NUMBER":"316954","CASS_NUM":"57507207","SMP_TAKEN_DT":"5/16/2005","CONC":".492","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER HELPER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-16"},{"SOURCE_ROW_NUMBER":"1318657","CASS_NUM":"50773199","SMP_TAKEN_DT":"4/15/2005","CONC":"1.666","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-04-15"},{"SOURCE_ROW_NUMBER":"578792","CASS_NUM":"50773188","SMP_TAKEN_DT":"4/13/2005","CONC":"1.598","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-04-13"},{"SOURCE_ROW_NUMBER":"1001212","CASS_NUM":"50773151","SMP_TAKEN_DT":"4/12/2005","CONC":"1.415","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-04-12"},{"SOURCE_ROW_NUMBER":"435434","CASS_NUM":"50773141","SMP_TAKEN_DT":"4/11/2005","CONC":".615","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-04-11"},{"SOURCE_ROW_NUMBER":"1608248","CASS_NUM":"57528395","SMP_TAKEN_DT":"3/16/2005","CONC":".132","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID WORKSHIFT","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-03-16"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":329,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":76,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":5,"firstDate":"2001-11-12","lastDate":"2002-03-18","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":3},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":57,"firstDate":"2002-03-26","lastDate":"2005-08-24","metrics":{"inspectors":77,"recentRows":0,"onSiteHours":835.5,"inspectionHours":1545.5,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"365695","EVENT_NO":"4054625","INSPECTION_BEGIN_DT":"08/24/2005","INSPECTION_END_DT":"08/24/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2005-08-24"},{"SOURCE_ROW_NUMBER":"867226","EVENT_NO":"4054746","INSPECTION_BEGIN_DT":"05/09/2005","INSPECTION_END_DT":"06/22/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"94.25","SUM_TOTAL_ON_SITE_HOURS":"69.25","sourceDate":"2005-05-09"},{"SOURCE_ROW_NUMBER":"612035","EVENT_NO":"4077471","INSPECTION_BEGIN_DT":"03/30/2005","INSPECTION_END_DT":"03/31/2005","ACTIVITY_CODE":"CEF","ACTIVITY":"OTHER TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"9.5","sourceDate":"2005-03-30"},{"SOURCE_ROW_NUMBER":"863806","EVENT_NO":"4075929","INSPECTION_BEGIN_DT":"03/01/2005","INSPECTION_END_DT":"03/01/2005","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2005-03-01"},{"SOURCE_ROW_NUMBER":"181283","EVENT_NO":"4076993","INSPECTION_BEGIN_DT":"01/24/2005","INSPECTION_END_DT":"03/25/2005","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"111.75","SUM_TOTAL_ON_SITE_HOURS":"44.5","sourceDate":"2005-01-24"},{"SOURCE_ROW_NUMBER":"1144579","EVENT_NO":"4077269","INSPECTION_BEGIN_DT":"11/09/2004","INSPECTION_END_DT":"11/09/2004","ACTIVITY_CODE":"CED","ACTIVITY":"RESP DUST TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11.5","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2004-11-09"},{"SOURCE_ROW_NUMBER":"778920","EVENT_NO":"4054505","INSPECTION_BEGIN_DT":"11/01/2004","INSPECTION_END_DT":"12/17/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"110","SUM_TOTAL_ON_SITE_HOURS":"60.25","sourceDate":"2004-11-01"},{"SOURCE_ROW_NUMBER":"412841","EVENT_NO":"4077158","INSPECTION_BEGIN_DT":"11/01/2004","INSPECTION_END_DT":"11/10/2004","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.5","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2004-11-01"},{"SOURCE_ROW_NUMBER":"121510","EVENT_NO":"4077262","INSPECTION_BEGIN_DT":"09/27/2004","INSPECTION_END_DT":"10/05/2004","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"21","SUM_TOTAL_ON_SITE_HOURS":"14","sourceDate":"2004-09-27"},{"SOURCE_ROW_NUMBER":"1141560","EVENT_NO":"4077153","INSPECTION_BEGIN_DT":"09/23/2004","INSPECTION_END_DT":"09/29/2004","ACTIVITY_CODE":"AFC","ACTIVITY":"NON-INJURY ACCIDENT INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11.5","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2004-09-23"},{"SOURCE_ROW_NUMBER":"432994","EVENT_NO":"4076417","INSPECTION_BEGIN_DT":"08/25/2004","INSPECTION_END_DT":"09/15/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"34","SUM_TOTAL_ON_SITE_HOURS":"20","sourceDate":"2004-08-25"},{"SOURCE_ROW_NUMBER":"609025","EVENT_NO":"4054295","INSPECTION_BEGIN_DT":"06/16/2004","INSPECTION_END_DT":"06/16/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2004-06-16"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":4,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002-Q4":{"hours":6254,"employees":12,"production":22633},"2002-Q3":{"hours":0,"employees":0,"production":0},"2002-Q2":{"hours":315,"employees":1,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":8,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002":{"hours":6569,"employees":8,"production":22633},"2003":{"hours":28057,"employees":13,"production":74503},"2004":{"hours":24082,"employees":12,"production":59874},"2005":{"hours":13018,"employees":14,"production":35665}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":15,"firstDate":"2003-09-03","lastDate":"2005-05-16","metrics":{"recentRows":0,"doseOver100":5,"actDoseTotal":1407,"pelDoseTotal":1124},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"248636","EVENT_NO":"4054746","SURVEY_DATE":"05/16/2005","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"66","PEL_DOSE_90":"46","SURVEY_TYPE":"I","sourceDate":"2005-05-16"},{"SOURCE_ROW_NUMBER":"248635","EVENT_NO":"4054746","SURVEY_DATE":"05/16/2005","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"110","PEL_DOSE_90":"102","SURVEY_TYPE":"I","sourceDate":"2005-05-16"},{"SOURCE_ROW_NUMBER":"248634","EVENT_NO":"4054746","SURVEY_DATE":"05/16/2005","OCCUPATION_CD_DESC":"CONTINUOUS MINER HELPER","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"72","PEL_DOSE_90":"62","SURVEY_TYPE":"I","sourceDate":"2005-05-16"},{"SOURCE_ROW_NUMBER":"248633","EVENT_NO":"4054746","SURVEY_DATE":"05/16/2005","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"78","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2005-05-16"},{"SOURCE_ROW_NUMBER":"248632","EVENT_NO":"4054746","SURVEY_DATE":"05/16/2005","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"108","PEL_DOSE_90":"86","SURVEY_TYPE":"I","sourceDate":"2005-05-16"},{"SOURCE_ROW_NUMBER":"248631","EVENT_NO":"4054062","SURVEY_DATE":"12/02/2003","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"90","PEL_DOSE_90":"70","SURVEY_TYPE":"I","sourceDate":"2003-12-02"},{"SOURCE_ROW_NUMBER":"248630","EVENT_NO":"4054062","SURVEY_DATE":"12/02/2003","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"89","PEL_DOSE_90":"71","SURVEY_TYPE":"I","sourceDate":"2003-12-02"},{"SOURCE_ROW_NUMBER":"248629","EVENT_NO":"4054062","SURVEY_DATE":"12/02/2003","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"94","PEL_DOSE_90":"72","SURVEY_TYPE":"I","sourceDate":"2003-12-02"},{"SOURCE_ROW_NUMBER":"248628","EVENT_NO":"4054062","SURVEY_DATE":"12/02/2003","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"151","PEL_DOSE_90":"130","SURVEY_TYPE":"I","sourceDate":"2003-12-02"},{"SOURCE_ROW_NUMBER":"248627","EVENT_NO":"4054062","SURVEY_DATE":"12/02/2003","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"94","PEL_DOSE_90":"72","SURVEY_TYPE":"I","sourceDate":"2003-12-02"},{"SOURCE_ROW_NUMBER":"248641","EVENT_NO":"4076550","SURVEY_DATE":"09/03/2003","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"125","PEL_DOSE_90":"110","SURVEY_TYPE":"I","sourceDate":"2003-09-03"},{"SOURCE_ROW_NUMBER":"248640","EVENT_NO":"4076550","SURVEY_DATE":"09/03/2003","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"67","PEL_DOSE_90":"47","SURVEY_TYPE":"I","sourceDate":"2003-09-03"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":15,"firstDate":"2002-05-28","lastDate":"2005-05-16","metrics":{"recentRows":0,"voidSamples":1,"maxQuartzPct":16.5,"validSamples":14,"quartzPctTotal":79.8},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"160995","CASSETTE_NO":"57507211","SAMPLE_DT":"05/16/2005","QUARTZ_PCT":"02.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-05-16"},{"SOURCE_ROW_NUMBER":"59339","CASSETTE_NO":"57539961","SAMPLE_DT":"11/30/2004","QUARTZ_PCT":"01.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-11-30"},{"SOURCE_ROW_NUMBER":"39384","CASSETTE_NO":"57474247","SAMPLE_DT":"06/16/2004","QUARTZ_PCT":"06.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-06-16"},{"SOURCE_ROW_NUMBER":"133213","CASSETTE_NO":"57463531","SAMPLE_DT":"04/07/2004","QUARTZ_PCT":"04.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-04-07"},{"SOURCE_ROW_NUMBER":"59099","CASSETTE_NO":"50723326","SAMPLE_DT":"03/05/2004","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2004-03-05"},{"SOURCE_ROW_NUMBER":"122600","CASSETTE_NO":"57463307","SAMPLE_DT":"02/17/2004","QUARTZ_PCT":"16.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-02-17"},{"SOURCE_ROW_NUMBER":"25715","CASSETTE_NO":"57463209","SAMPLE_DT":"01/29/2004","QUARTZ_PCT":"04.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-01-29"},{"SOURCE_ROW_NUMBER":"151056","CASSETTE_NO":"57462571","SAMPLE_DT":"11/19/2003","QUARTZ_PCT":"07.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-11-19"},{"SOURCE_ROW_NUMBER":"137696","CASSETTE_NO":"57462573","SAMPLE_DT":"11/19/2003","QUARTZ_PCT":"06.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-11-19"},{"SOURCE_ROW_NUMBER":"108270","CASSETTE_NO":"57462367","SAMPLE_DT":"09/03/2003","QUARTZ_PCT":"02.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-09-03"},{"SOURCE_ROW_NUMBER":"7448","CASSETTE_NO":"57462340","SAMPLE_DT":"09/02/2003","QUARTZ_PCT":"07.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-09-02"},{"SOURCE_ROW_NUMBER":"98462","CASSETTE_NO":"57417902","SAMPLE_DT":"08/19/2002","QUARTZ_PCT":"04.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-08-19"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":179,"firstDate":"2002-04-30","lastDate":"2005-05-26","metrics":{"ss":64,"amountDue":18797,"contested":0,"amountPaid":974.49,"recentRows":0,"section104d":3,"unterminated":0,"proposedPenalty":18797},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2826546","VIOLATION_NO":"7097832","VIOLATION_ISSUE_DT":"05/26/2005","SIG_SUB":"Y","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/26/2005","PROPOSED_PENALTY":"154","AMOUNT_DUE":"154","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2005-05-26"},{"SOURCE_ROW_NUMBER":"2826545","VIOLATION_NO":"7097831","VIOLATION_ISSUE_DT":"05/26/2005","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/26/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2005-05-26"},{"SOURCE_ROW_NUMBER":"2826544","VIOLATION_NO":"7097829","VIOLATION_ISSUE_DT":"05/24/2005","SIG_SUB":"N","PART_SECTION":"75.1107-16(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/26/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2005-05-24"},{"SOURCE_ROW_NUMBER":"2826543","VIOLATION_NO":"7097828","VIOLATION_ISSUE_DT":"05/24/2005","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/26/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2005-05-24"},{"SOURCE_ROW_NUMBER":"2826542","VIOLATION_NO":"7097822","VIOLATION_ISSUE_DT":"05/16/2005","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/17/2005","PROPOSED_PENALTY":"154","AMOUNT_DUE":"154","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2005-05-16"},{"SOURCE_ROW_NUMBER":"2826541","VIOLATION_NO":"7097821","VIOLATION_ISSUE_DT":"05/16/2005","SIG_SUB":"Y","PART_SECTION":"75.388(a)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"3","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"05/17/2005","CONTESTED_IND":"N","sourceDate":"2005-05-16"},{"SOURCE_ROW_NUMBER":"2826540","VIOLATION_NO":"7097820","VIOLATION_ISSUE_DT":"05/16/2005","SIG_SUB":"N","PART_SECTION":"70.207(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/16/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2005-05-16"},{"SOURCE_ROW_NUMBER":"2826539","VIOLATION_NO":"7097819","VIOLATION_ISSUE_DT":"05/12/2005","SIG_SUB":"Y","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/12/2005","PROPOSED_PENALTY":"154","AMOUNT_DUE":"154","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2005-05-12"},{"SOURCE_ROW_NUMBER":"2826538","VIOLATION_NO":"7097818","VIOLATION_ISSUE_DT":"05/12/2005","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/16/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2005-05-12"},{"SOURCE_ROW_NUMBER":"2826537","VIOLATION_NO":"7097817","VIOLATION_ISSUE_DT":"05/12/2005","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"05/13/2005","CONTESTED_IND":"N","sourceDate":"2005-05-12"},{"SOURCE_ROW_NUMBER":"2826536","VIOLATION_NO":"7097816","VIOLATION_ISSUE_DT":"05/11/2005","SIG_SUB":"Y","PART_SECTION":"77.200","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/11/2005","PROPOSED_PENALTY":"154","AMOUNT_DUE":"154","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2005-05-11"},{"SOURCE_ROW_NUMBER":"2826535","VIOLATION_NO":"7097815","VIOLATION_ISSUE_DT":"05/11/2005","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/12/2005","PROPOSED_PENALTY":"437","AMOUNT_DUE":"437","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2005-05-11"}]}],"safety":{"href":"/api/v1/mines/4608928/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4608928/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-16","heading":"Inspection of fire suppression devices.","id":"75.1107-16","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-16","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) All fire suppression devices shall be visually inspected at least once each week by a person qualified to make such inspections.\n\n(b) Each fire suppression device shall be tested and maintained in accordance with the requirements specified in the appropriate National Fire Code listed as follows for the type and kind of device used:\n\nNational Fire Code No. 11A “High Expansion Foam Systems” (NFPA No. 11A—1970). National Fire Code No. 13A “Care and Maintenance of Sprinkler Systems” (NFPA No. 13A—1971). National Fire Code No. 15 “Water Spray Fixed Systems for Fire Protection” (NFPA No. 15—1969). National Fire Code No. 17 “Dry Chemical Extinguishing Systems” (NFPA No. 17—1969). National Fire Code No. 72A “Local Protective Signaling Systems” (NFPA No. 72A—1967). National Fire Code No. 198 “Care of Fire Hose” (NFPA No. 198—1969).\n\n(c) A record of the inspections required by this section shall be maintained by the operator. The record of the weekly inspections may be maintained at an appropriate location by each fire suppression device.\n\n[37 FR 15304, July 29, 1972, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.403","heading":"Maintenance of incombustible content of rock dust.","id":"75.403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 80 percent. Where methane is present in any ventilating current, the percent of incombustible content of such combined dust shall be increased 0.4 percent for each 0.1 percent of methane.\n\n[75 FR 57857, Sept. 23, 2010; 76 FR 35978, June 21, 2011]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","heading":"Boreholes in advance of mining.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.388","part":"75","subchapter":"O","subpart":"D","id":"75.388","citation":"30 CFR 75.388","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1725","heading":"Machinery and equipment; operation and maintenance.","id":"75.1725","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1725","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":2},{"chapter":"I","heading":"Surface installations; general.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.200","part":"77","subchapter":"O","subpart":"C","id":"77.200","citation":"30 CFR 77.200","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4608928","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}