{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4608902","name":"No 4","status":"Abandoned and Sealed","status_date":"2008-08-05","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Mingo","nearest_town":"Dingess","operator_id":"P23152","operator_name":"Laurel Creek Company Inc","controller_id":"0041211","controller_name":"Alpha Natural Resources, Inc.","district":"C04","office":"Beckley District","employees":0,"latitude":37.832777,"longitude":-82.18},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":1547},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4608902","name":"No 4"},"operator":{"type":"operator","id":"P23152","name":"Laurel Creek Company Inc"},"controller":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15532","name":"Rag Aktiengesellschaft"},"object":{"type":"mine","id":"4608902","name":"No 4"},"validFrom":"1995-06-01","validTo":"2004-07-29","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608902|C15532|1995-06-01|2004-07-29"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23152","name":"Laurel Creek Company Inc"},"object":{"type":"mine","id":"4608902","name":"No 4"},"validFrom":"2001-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608902|P23152|2001-06-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15532","name":"Rag Aktiengesellschaft"},"object":{"type":"operator","id":"P23152","name":"Laurel Creek Company Inc"},"validFrom":"2001-06-01","validTo":"2004-07-29","current":false,"derived":true,"evidenceMineId":"4608902","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608902|P23152|2001-06-01|C15532|1995-06-01|95861"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0044281","name":"Foundation Coal Corporation"},"object":{"type":"mine","id":"4608902","name":"No 4"},"validFrom":"2004-07-30","validTo":"2009-07-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608902|0044281|2004-07-30|2009-07-30"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0044281","name":"Foundation Coal Corporation"},"object":{"type":"operator","id":"P23152","name":"Laurel Creek Company Inc"},"validFrom":"2004-07-30","validTo":"2009-07-30","current":false,"derived":true,"evidenceMineId":"4608902","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608902|P23152|2001-06-01|0044281|2004-07-30|4988"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"4608902","name":"No 4"},"validFrom":"2009-07-31","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608902|0041211|2009-07-31|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P23152","name":"Laurel Creek Company Inc"},"validFrom":"2009-07-31","validTo":null,"current":true,"derived":true,"evidenceMineId":"4608902","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608902|P23152|2001-06-01|0041211|2009-07-31|1796"}}],"coverage":{"historyRecords":3,"edgeCount":7,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":28,"firstDate":"2002-04-09","lastDate":"2007-05-04","metrics":{"daysLost":692,"injuries":24,"fatalities":0,"recentRows":0,"restrictedDays":22,"contractorRecords":2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"29718","DOCUMENT_NO":"220071430014","ACCIDENT_DT":"05/04/2007","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"8","NARRATIVE":"He was lifting oxygen bottle; felt pain in lower left stomach. *****Employee did not miss work until surgery was scheduled 05-16-2007******","sourceDate":"2007-05-04"},{"SOURCE_ROW_NUMBER":"236264","DOCUMENT_NO":"220070720011","ACCIDENT_DT":"03/09/2007","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While bolting top, drill steel became stuck in the top and came loose hitting finger between drill steel and drill pot; cutting right ring finger.","sourceDate":"2007-03-09"},{"SOURCE_ROW_NUMBER":"89883","DOCUMENT_NO":"220070570016","ACCIDENT_DT":"02/21/2007","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Location: Old works in return; entry No.3, spad no.2040. Distance from active face: 2,000', Airway: neutral. Size: L-20', W-20', H-5'; 48\" resin fully grouted, no cribs or timbers installed prior to fall. Strata: shale, no coal rider seam present. All entrances to fall breakered off, area will not be rehabilitated.","sourceDate":"2007-02-21"},{"SOURCE_ROW_NUMBER":"128409","DOCUMENT_NO":"220070510038","ACCIDENT_DT":"02/19/2007","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Location: No.4 belt, entry No.2, spad no.2608; Distance from active face: 600'; No personal injuries; Size: L-60', W-18', H-8 - 10'; 48\" resin; 6 or 7 cribs installed prior to fall; Strata: mixed; no coal rider seam present; All entrances are breakered off, area will not be rehabilitated.","sourceDate":"2007-02-19"},{"SOURCE_ROW_NUMBER":"68341","DOCUMENT_NO":"220070430026","ACCIDENT_DT":"02/05/2007","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Fall occured on No.4 belt linea t brk. 16 approx. 6' - 8' high 20 X 20 in intersection.","sourceDate":"2007-02-05"},{"SOURCE_ROW_NUMBER":"55474","DOCUMENT_NO":"220070290017","ACCIDENT_DT":"01/25/2007","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was cutting plastic water line, knife slipped and cut left thumb.","sourceDate":"2007-01-25"},{"SOURCE_ROW_NUMBER":"128408","DOCUMENT_NO":"220070100004","ACCIDENT_DT":"01/09/2007","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Actual date of fall is unknown. Size: L-60';W-19';H-6'; 48\" resin fully grouted resin; 5 cribs installed prior to fall; Strata: laminated; No coal rider seam present; All entrances will be breakered off; Area will be rehabilitated; Airway: neural, intake; distance from active face: 5,100'.","sourceDate":"2007-01-09"},{"SOURCE_ROW_NUMBER":"132767","DOCUMENT_NO":"220070660036","ACCIDENT_DT":"11/16/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"81","NARRATIVE":"while servicing roof bolter, was going around roof bolter and stepped on pc. of curtain a lump of coal was underneath it causing employee to twist left knee. Accident happened 11-16-2006 at this time the employee did not miss work.  He had surgery on his knee on 02-20-2007 and started missing work at that time.","sourceDate":"2006-11-16"},{"SOURCE_ROW_NUMBER":"193115","DOCUMENT_NO":"220062620028","ACCIDENT_DT":"09/14/2006","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While taking apart style jack, I had it standing in the up right position. When I turned around to get a hammer, the style jack fell striking me in the right lower leg.","sourceDate":"2006-09-14"},{"SOURCE_ROW_NUMBER":"8246","DOCUMENT_NO":"220062070005","ACCIDENT_DT":"07/20/2006","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"FALLING/SLIDING/ROLLING MATERIALS","ACCIDENT_TYPE":"Struck by rolling or sliding object","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"changing ripper motor on miner, had motor on hoist moving in place when motor rolled over and caught left thumb against crib block being used as a guide.","sourceDate":"2006-07-20"},{"SOURCE_ROW_NUMBER":"231909","DOCUMENT_NO":"220061100002","ACCIDENT_DT":"04/18/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"Pc. of draw rock fell striking employee on head and neck","sourceDate":"2006-04-18"},{"SOURCE_ROW_NUMBER":"34048","DOCUMENT_NO":"220060470010","ACCIDENT_DT":"02/10/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"40","NARRATIVE":"was lifting a pc. of structure, bent over to pick it up and felt something pull in rt. side","sourceDate":"2006-02-10"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2008-08-05","lastDate":"2008-08-05","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":151,"firstDate":"2002-04-15","lastDate":"2008-03-07","metrics":{"ss":46,"delinquent":140,"recentRows":0,"paidPenalty":24083,"proposedPenalty":24677,"currentAssessment":24083},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"812841","VIOLATION_NO":"7267579","ISSUE_DT":"03/07/2008","CFR_STANDARD_CD":"75.1505(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-03-07"},{"SOURCE_ROW_NUMBER":"812840","VIOLATION_NO":"7267578","ISSUE_DT":"03/01/2008","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1026.00","CURRENT_ASSESSMENT_AMT":"1026.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-03-01"},{"SOURCE_ROW_NUMBER":"812797","VIOLATION_NO":"7267556","ISSUE_DT":"12/12/2007","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"745.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-12-12"},{"SOURCE_ROW_NUMBER":"812796","VIOLATION_NO":"7267555","ISSUE_DT":"12/12/2007","CFR_STANDARD_CD":"75.1100-2(f)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-12-12"},{"SOURCE_ROW_NUMBER":"812795","VIOLATION_NO":"7267543","ISSUE_DT":"10/23/2007","CFR_STANDARD_CD":"75.1200","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"138.00","CURRENT_ASSESSMENT_AMT":"138.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-10-23"},{"SOURCE_ROW_NUMBER":"829384","VIOLATION_NO":"7268434","ISSUE_DT":"08/22/2007","CFR_STANDARD_CD":"75.904","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"207.00","CURRENT_ASSESSMENT_AMT":"207.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-08-22"},{"SOURCE_ROW_NUMBER":"829383","VIOLATION_NO":"7268433","ISSUE_DT":"08/21/2007","CFR_STANDARD_CD":"77.904","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"207.00","CURRENT_ASSESSMENT_AMT":"207.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-08-21"},{"SOURCE_ROW_NUMBER":"829382","VIOLATION_NO":"7268432","ISSUE_DT":"08/20/2007","CFR_STANDARD_CD":"75.1403-8(e)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1026.00","CURRENT_ASSESSMENT_AMT":"1026.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-08-20"},{"SOURCE_ROW_NUMBER":"829381","VIOLATION_NO":"7268431","ISSUE_DT":"08/20/2007","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"634.00","CURRENT_ASSESSMENT_AMT":"634.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-08-20"},{"SOURCE_ROW_NUMBER":"829380","VIOLATION_NO":"7268430","ISSUE_DT":"08/20/2007","CFR_STANDARD_CD":"75.1722(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1026.00","CURRENT_ASSESSMENT_AMT":"1026.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-08-20"},{"SOURCE_ROW_NUMBER":"829379","VIOLATION_NO":"7268429","ISSUE_DT":"08/20/2007","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"207.00","CURRENT_ASSESSMENT_AMT":"207.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-08-20"},{"SOURCE_ROW_NUMBER":"829277","VIOLATION_NO":"7268333","ISSUE_DT":"05/24/2007","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"117.00","CURRENT_ASSESSMENT_AMT":"117.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-05-24"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":5,"firstDate":"2007-02-16","lastDate":"2008-12-17","metrics":{"appeals":0,"decisions":5,"recentRows":0,"decisionPenalty":774,"originalPenalty":1368},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"17590","VIOLATION_NO":"7267556","DOCKET_NO":"WEVA 2008-504","DECISION_DT":"12/17/2008","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"745.00","DECISION_PENALTY_AMT":"151.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2008-12-17"},{"SOURCE_ROW_NUMBER":"193955","VIOLATION_NO":"7136532","DOCKET_NO":"WEVA 2006-855","DECISION_DT":"02/16/2007","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"144.00","DECISION_PENALTY_AMT":"144.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2007-02-16"},{"SOURCE_ROW_NUMBER":"8183","VIOLATION_NO":"7136534","DOCKET_NO":"WEVA 2006-855","DECISION_DT":"02/16/2007","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"144.00","DECISION_PENALTY_AMT":"144.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2007-02-16"},{"SOURCE_ROW_NUMBER":"8182","VIOLATION_NO":"7136531","DOCKET_NO":"WEVA 2006-855","DECISION_DT":"02/16/2007","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"144.00","DECISION_PENALTY_AMT":"144.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2007-02-16"},{"SOURCE_ROW_NUMBER":"7917","VIOLATION_NO":"7136536","DOCKET_NO":"WEVA 2006-855","DECISION_DT":"02/16/2007","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"191.00","DECISION_PENALTY_AMT":"191.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2007-02-16"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":425,"firstDate":"2002-05-01","lastDate":"2008-03-26","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":6,"validSamples":419,"maxConcentration":4.002,"concentrationTotal":266.878},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1644015","CASS_NUM":"57719183","SMP_TAKEN_DT":"3/26/2008","CONC":".763","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-03-26"},{"SOURCE_ROW_NUMBER":"1398454","CASS_NUM":"57719215","SMP_TAKEN_DT":"3/26/2008","CONC":"1.162","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-03-26"},{"SOURCE_ROW_NUMBER":"1363767","CASS_NUM":"57719222","SMP_TAKEN_DT":"3/26/2008","CONC":".741","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-03-26"},{"SOURCE_ROW_NUMBER":"1244000","CASS_NUM":"57719175","SMP_TAKEN_DT":"3/26/2008","CONC":"1.335","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-03-26"},{"SOURCE_ROW_NUMBER":"985497","CASS_NUM":"57719196","SMP_TAKEN_DT":"3/26/2008","CONC":"1.124","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-03-26"},{"SOURCE_ROW_NUMBER":"455880","CASS_NUM":"57719160","SMP_TAKEN_DT":"3/26/2008","CONC":".708","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-03-26"},{"SOURCE_ROW_NUMBER":"99510","CASS_NUM":"57719154","SMP_TAKEN_DT":"3/26/2008","CONC":".13","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-03-26"},{"SOURCE_ROW_NUMBER":"275267","CASS_NUM":"50951140","SMP_TAKEN_DT":"3/18/2008","CONC":".099","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-03-18"},{"SOURCE_ROW_NUMBER":"1326341","CASS_NUM":"57718831","SMP_TAKEN_DT":"3/1/2008","CONC":"1.14","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-03-01"},{"SOURCE_ROW_NUMBER":"1308651","CASS_NUM":"57718896","SMP_TAKEN_DT":"3/1/2008","CONC":".049","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-03-01"},{"SOURCE_ROW_NUMBER":"1232769","CASS_NUM":"57718861","SMP_TAKEN_DT":"3/1/2008","CONC":".293","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ELECTRICIAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-03-01"},{"SOURCE_ROW_NUMBER":"1219298","CASS_NUM":"57718925","SMP_TAKEN_DT":"3/1/2008","CONC":".495","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SECTION FOREMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-03-01"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":7,"firstDate":"2003-09-10","lastDate":"2006-08-22","metrics":{"linkedIssuances":7},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":5,"firstDate":"2006-05-16","lastDate":"2007-12-12","metrics":{"decisions":5,"ssChanged":5,"recentRows":0,"decisionPenalty":774,"proposedPenalty":1368},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"399828","CITATION_NO":"7267556","CITATION_ISSUE_DT":"12/12/2007","DOCKET_NO":"WEVA 2008-504","DECISION_DT":"12/17/2008","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"745.00","DECISION_PENALTY_AMT":"151.00","sourceDate":"2007-12-12"},{"SOURCE_ROW_NUMBER":"342870","CITATION_NO":"7136534","CITATION_ISSUE_DT":"05/16/2006","DOCKET_NO":"WEVA 2006-855","DECISION_DT":"02/16/2007","CFR_STANDARD_CODE":"75.1725(a)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"144.00","DECISION_PENALTY_AMT":"144.00","sourceDate":"2006-05-16"},{"SOURCE_ROW_NUMBER":"229357","CITATION_NO":"7136531","CITATION_ISSUE_DT":"05/16/2006","DOCKET_NO":"WEVA 2006-855","DECISION_DT":"02/16/2007","CFR_STANDARD_CODE":"77.502","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"144.00","DECISION_PENALTY_AMT":"144.00","sourceDate":"2006-05-16"},{"SOURCE_ROW_NUMBER":"173111","CITATION_NO":"7136536","CITATION_ISSUE_DT":"05/16/2006","DOCKET_NO":"WEVA 2006-855","DECISION_DT":"02/16/2007","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"191.00","DECISION_PENALTY_AMT":"191.00","sourceDate":"2006-05-16"},{"SOURCE_ROW_NUMBER":"117026","CITATION_NO":"7136532","CITATION_ISSUE_DT":"05/16/2006","DOCKET_NO":"WEVA 2006-855","DECISION_DT":"02/16/2007","CFR_STANDARD_CODE":"77.400","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"144.00","DECISION_PENALTY_AMT":"144.00","sourceDate":"2006-05-16"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":491,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":5,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":93,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":5,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"2001-06-01","lastDate":"2001-06-01","metrics":{"recentRows":0,"currentOperatorTenures":3,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":54,"firstDate":"2002-03-19","lastDate":"2008-06-06","metrics":{"inspectors":67,"recentRows":0,"onSiteHours":1672.75,"inspectionHours":2618,"inspectionSamples":108},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1054998","EVENT_NO":"4121509","INSPECTION_BEGIN_DT":"06/06/2008","INSPECTION_END_DT":"06/06/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2008-06-06"},{"SOURCE_ROW_NUMBER":"953453","EVENT_NO":"4112084","INSPECTION_BEGIN_DT":"02/29/2008","INSPECTION_END_DT":"03/31/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"112.25","SUM_TOTAL_ON_SITE_HOURS":"54.25","sourceDate":"2008-02-29"},{"SOURCE_ROW_NUMBER":"126969","EVENT_NO":"4112074","INSPECTION_BEGIN_DT":"10/09/2007","INSPECTION_END_DT":"12/19/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"147","SUM_TOTAL_ON_SITE_HOURS":"84.5","sourceDate":"2007-10-09"},{"SOURCE_ROW_NUMBER":"816654","EVENT_NO":"4115977","INSPECTION_BEGIN_DT":"08/20/2007","INSPECTION_END_DT":"08/23/2007","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"25.5","SUM_TOTAL_ON_SITE_HOURS":"16","sourceDate":"2007-08-20"},{"SOURCE_ROW_NUMBER":"982967","EVENT_NO":"4115966","INSPECTION_BEGIN_DT":"04/19/2007","INSPECTION_END_DT":"06/21/2007","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"60","SUM_TOTAL_ON_SITE_HOURS":"34.5","sourceDate":"2007-04-19"},{"SOURCE_ROW_NUMBER":"1153155","EVENT_NO":"4115958","INSPECTION_BEGIN_DT":"01/10/2007","INSPECTION_END_DT":"03/06/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"164","SUM_TOTAL_ON_SITE_HOURS":"94.25","sourceDate":"2007-01-10"},{"SOURCE_ROW_NUMBER":"391216","EVENT_NO":"4116609","INSPECTION_BEGIN_DT":"12/09/2006","INSPECTION_END_DT":"12/09/2006","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2006-12-09"},{"SOURCE_ROW_NUMBER":"808823","EVENT_NO":"4109933","INSPECTION_BEGIN_DT":"11/06/2006","INSPECTION_END_DT":"12/14/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"100.5","SUM_TOTAL_ON_SITE_HOURS":"64","sourceDate":"2006-11-06"},{"SOURCE_ROW_NUMBER":"690223","EVENT_NO":"4116053","INSPECTION_BEGIN_DT":"08/23/2006","INSPECTION_END_DT":"08/24/2006","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"15","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2006-08-23"},{"SOURCE_ROW_NUMBER":"107842","EVENT_NO":"4109929","INSPECTION_BEGIN_DT":"08/04/2006","INSPECTION_END_DT":"10/02/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"106.5","SUM_TOTAL_ON_SITE_HOURS":"59.5","sourceDate":"2006-08-04"},{"SOURCE_ROW_NUMBER":"57642","EVENT_NO":"4064974","INSPECTION_BEGIN_DT":"05/16/2006","INSPECTION_END_DT":"07/05/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"84.5","SUM_TOTAL_ON_SITE_HOURS":"44","sourceDate":"2006-05-16"},{"SOURCE_ROW_NUMBER":"187495","EVENT_NO":"4109919","INSPECTION_BEGIN_DT":"01/09/2006","INSPECTION_END_DT":"03/31/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"112","SUM_TOTAL_ON_SITE_HOURS":"69","sourceDate":"2006-01-09"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":52,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2008-Q3":{"hours":0,"employees":0,"production":0},"2008-Q2":{"hours":0,"employees":0,"production":0},"2008-Q1":{"hours":20989,"employees":35,"production":60395},"2007-Q4":{"hours":20986,"employees":35,"production":65951},"2007-Q3":{"hours":20694,"employees":36,"production":71948},"2007-Q2":{"hours":21506,"employees":36,"production":89997},"2007-Q1":{"hours":19995,"employees":31,"production":85190},"2006-Q4":{"hours":19993,"employees":33,"production":94446},"2006-Q3":{"hours":18964,"employees":33,"production":83447},"2006-Q2":{"hours":16793,"employees":35,"production":85095},"2006-Q1":{"hours":16147,"employees":35,"production":98191},"2005-Q4":{"hours":18251,"employees":35,"production":101472}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":14,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002":{"hours":51732,"employees":34,"production":229096},"2003":{"hours":74884,"employees":33,"production":407811},"2004":{"hours":75643,"employees":34,"production":409066},"2005":{"hours":78627,"employees":34,"production":414588},"2006":{"hours":71897,"employees":34,"production":361179},"2007":{"hours":83181,"employees":35,"production":313086},"2008":{"hours":20989,"employees":35,"production":60395}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":20,"firstDate":"2003-06-04","lastDate":"2007-10-23","metrics":{"recentRows":0,"doseOver100":11,"actDoseTotal":44980,"pelDoseTotal":26262},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"248188","EVENT_NO":"4112074","SURVEY_DATE":"10/23/2007","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"067","ACT_DOSE_85":"118","PEL_DOSE_90":"100","SURVEY_TYPE":"I","sourceDate":"2007-10-23"},{"SOURCE_ROW_NUMBER":"248187","EVENT_NO":"4112074","SURVEY_DATE":"10/23/2007","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"067","ACT_DOSE_85":"85","PEL_DOSE_90":"82","SURVEY_TYPE":"I","sourceDate":"2007-10-23"},{"SOURCE_ROW_NUMBER":"248186","EVENT_NO":"4112074","SURVEY_DATE":"10/23/2007","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"067","ACT_DOSE_85":"85","PEL_DOSE_90":"80","SURVEY_TYPE":"I","sourceDate":"2007-10-23"},{"SOURCE_ROW_NUMBER":"248185","EVENT_NO":"4112074","SURVEY_DATE":"10/23/2007","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"067","ACT_DOSE_85":"80","PEL_DOSE_90":"79","SURVEY_TYPE":"I","sourceDate":"2007-10-23"},{"SOURCE_ROW_NUMBER":"248184","EVENT_NO":"4112074","SURVEY_DATE":"10/23/2007","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"108","PEL_DOSE_90":"104","SURVEY_TYPE":"I","sourceDate":"2007-10-23"},{"SOURCE_ROW_NUMBER":"248183","EVENT_NO":"4107450","SURVEY_DATE":"08/31/2005","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"067","ACT_DOSE_85":"39","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2005-08-31"},{"SOURCE_ROW_NUMBER":"248182","EVENT_NO":"4107450","SURVEY_DATE":"08/31/2005","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"067","ACT_DOSE_85":"41","PEL_DOSE_90":"20","SURVEY_TYPE":"I","sourceDate":"2005-08-31"},{"SOURCE_ROW_NUMBER":"248181","EVENT_NO":"4107450","SURVEY_DATE":"08/31/2005","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"067","ACT_DOSE_85":"38","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2005-08-31"},{"SOURCE_ROW_NUMBER":"248180","EVENT_NO":"4107450","SURVEY_DATE":"08/31/2005","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"067","ACT_DOSE_85":"56","PEL_DOSE_90":"41","SURVEY_TYPE":"I","sourceDate":"2005-08-31"},{"SOURCE_ROW_NUMBER":"248179","EVENT_NO":"4107450","SURVEY_DATE":"08/31/2005","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"65","PEL_DOSE_90":"52","SURVEY_TYPE":"I","sourceDate":"2005-08-31"},{"SOURCE_ROW_NUMBER":"248178","EVENT_NO":"4107418","SURVEY_DATE":"09/24/2004","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"067","ACT_DOSE_85":"3800","PEL_DOSE_90":"2000","SURVEY_TYPE":"I","sourceDate":"2004-09-24"},{"SOURCE_ROW_NUMBER":"248177","EVENT_NO":"4107418","SURVEY_DATE":"09/24/2004","OCCUPATION_CD_DESC":"TRACTOR OPERATOR/MOTORMAN","MACHINE_CD":"38","MANUFACTURER_CD":"067","ACT_DOSE_85":"4700","PEL_DOSE_90":"1900","SURVEY_TYPE":"I","sourceDate":"2004-09-24"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":39,"firstDate":"2002-05-30","lastDate":"2008-03-26","metrics":{"recentRows":0,"voidSamples":1,"maxQuartzPct":18.6,"validSamples":38,"quartzPctTotal":367.3},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"93197","CASSETTE_NO":"57719222","SAMPLE_DT":"03/26/2008","QUARTZ_PCT":"10.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"INVALID CERTIFICATION NUMBER","sourceDate":"2008-03-26"},{"SOURCE_ROW_NUMBER":"153975","CASSETTE_NO":"57718933","SAMPLE_DT":"03/01/2008","QUARTZ_PCT":"11.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-03-01"},{"SOURCE_ROW_NUMBER":"76314","CASSETTE_NO":"57718848","SAMPLE_DT":"03/01/2008","QUARTZ_PCT":"18.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-03-01"},{"SOURCE_ROW_NUMBER":"29666","CASSETTE_NO":"57638271","SAMPLE_DT":"10/18/2007","QUARTZ_PCT":"07.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-10-18"},{"SOURCE_ROW_NUMBER":"9482","CASSETTE_NO":"50907633","SAMPLE_DT":"07/11/2007","QUARTZ_PCT":"09.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-07-11"},{"SOURCE_ROW_NUMBER":"57359","CASSETTE_NO":"57647419","SAMPLE_DT":"09/25/2006","QUARTZ_PCT":"09.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-09-25"},{"SOURCE_ROW_NUMBER":"15183","CASSETTE_NO":"57647410","SAMPLE_DT":"09/25/2006","QUARTZ_PCT":"06.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-09-25"},{"SOURCE_ROW_NUMBER":"147474","CASSETTE_NO":"57647180","SAMPLE_DT":"06/28/2006","QUARTZ_PCT":"14.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-06-28"},{"SOURCE_ROW_NUMBER":"96088","CASSETTE_NO":"57647154","SAMPLE_DT":"06/28/2006","QUARTZ_PCT":"13.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-06-28"},{"SOURCE_ROW_NUMBER":"82191","CASSETTE_NO":"57611538","SAMPLE_DT":"02/22/2006","QUARTZ_PCT":"09.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-02-22"},{"SOURCE_ROW_NUMBER":"68720","CASSETTE_NO":"57611539","SAMPLE_DT":"02/22/2006","QUARTZ_PCT":"05.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-02-22"},{"SOURCE_ROW_NUMBER":"24930","CASSETTE_NO":"57551300","SAMPLE_DT":"10/31/2005","QUARTZ_PCT":"04.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-10-31"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":158,"firstDate":"2002-04-15","lastDate":"2008-03-07","metrics":{"ss":46,"amountDue":24083,"contested":5,"amountPaid":24083,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":24677},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2822168","VIOLATION_NO":"7267579","VIOLATION_ISSUE_DT":"03/07/2008","SIG_SUB":"N","PART_SECTION":"75.1505(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/07/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-03-07"},{"SOURCE_ROW_NUMBER":"2822167","VIOLATION_NO":"7267578","VIOLATION_ISSUE_DT":"03/01/2008","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/07/2008","PROPOSED_PENALTY":"1026","AMOUNT_DUE":"1026","AMOUNT_PAID":"1026","CONTESTED_IND":"N","sourceDate":"2008-03-01"},{"SOURCE_ROW_NUMBER":"2822263","VIOLATION_NO":"7267556","VIOLATION_ISSUE_DT":"12/12/2007","SIG_SUB":"N","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"12/13/2007","PROPOSED_PENALTY":"745","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"Y","DOCKET_NO":"WEVA 2008-504","sourceDate":"2007-12-12"},{"SOURCE_ROW_NUMBER":"2822262","VIOLATION_NO":"7267555","VIOLATION_ISSUE_DT":"12/12/2007","SIG_SUB":"N","PART_SECTION":"75.1100-2(f)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/12/2007","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2007-12-12"},{"SOURCE_ROW_NUMBER":"2822261","VIOLATION_NO":"7267543","VIOLATION_ISSUE_DT":"10/23/2007","SIG_SUB":"N","PART_SECTION":"75.1200","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/23/2007","PROPOSED_PENALTY":"138","AMOUNT_DUE":"138","AMOUNT_PAID":"138","CONTESTED_IND":"N","sourceDate":"2007-10-23"},{"SOURCE_ROW_NUMBER":"2822243","VIOLATION_NO":"7268434","VIOLATION_ISSUE_DT":"08/22/2007","SIG_SUB":"N","PART_SECTION":"75.904","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/22/2007","PROPOSED_PENALTY":"207","AMOUNT_DUE":"207","AMOUNT_PAID":"207","CONTESTED_IND":"N","sourceDate":"2007-08-22"},{"SOURCE_ROW_NUMBER":"2822242","VIOLATION_NO":"7268433","VIOLATION_ISSUE_DT":"08/21/2007","SIG_SUB":"N","PART_SECTION":"77.904","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/21/2007","PROPOSED_PENALTY":"207","AMOUNT_DUE":"207","AMOUNT_PAID":"207","CONTESTED_IND":"N","sourceDate":"2007-08-21"},{"SOURCE_ROW_NUMBER":"2822241","VIOLATION_NO":"7268432","VIOLATION_ISSUE_DT":"08/20/2007","SIG_SUB":"Y","PART_SECTION":"75.1403-8(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/20/2007","PROPOSED_PENALTY":"1026","AMOUNT_DUE":"1026","AMOUNT_PAID":"1026","CONTESTED_IND":"N","sourceDate":"2007-08-20"},{"SOURCE_ROW_NUMBER":"2822240","VIOLATION_NO":"7268431","VIOLATION_ISSUE_DT":"08/20/2007","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/20/2007","PROPOSED_PENALTY":"634","AMOUNT_DUE":"634","AMOUNT_PAID":"634","CONTESTED_IND":"N","sourceDate":"2007-08-20"},{"SOURCE_ROW_NUMBER":"2822239","VIOLATION_NO":"7268430","VIOLATION_ISSUE_DT":"08/20/2007","SIG_SUB":"Y","PART_SECTION":"75.1722(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/20/2007","PROPOSED_PENALTY":"1026","AMOUNT_DUE":"1026","AMOUNT_PAID":"1026","CONTESTED_IND":"N","sourceDate":"2007-08-20"},{"SOURCE_ROW_NUMBER":"2822238","VIOLATION_NO":"7268429","VIOLATION_ISSUE_DT":"08/20/2007","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/20/2007","PROPOSED_PENALTY":"207","AMOUNT_DUE":"207","AMOUNT_PAID":"207","CONTESTED_IND":"N","sourceDate":"2007-08-20"},{"SOURCE_ROW_NUMBER":"2822196","VIOLATION_NO":"7268333","VIOLATION_ISSUE_DT":"05/24/2007","SIG_SUB":"N","PART_SECTION":"75.1100-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/24/2007","PROPOSED_PENALTY":"117","AMOUNT_DUE":"117","AMOUNT_PAID":"117","CONTESTED_IND":"N","sourceDate":"2007-05-24"}]}],"safety":{"href":"/api/v1/mines/4608902/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4608902/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1505","heading":"Escapeway maps.","id":"75.1505","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-P/section-75.1505","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"P","subpartHeading":"Subpart P—Mine Emergencies","text":"(a) Content and accessibility. An escapeway map shall show the designated escapeways from the working sections or the miners' work stations to the surface or the exits at the bottom of the shaft or slope, refuge alternatives, and SCSR storage locations. The escapeway map shall be posted or readily accessible for all miners—\n\n(1) In each working section;\n\n(2) In each area where mechanized mining equipment is being installed or removed;\n\n(3) At the refuge alternative; and\n\n(4) At a surface location of the mine where miners congregate, such as at the mine bulletin board, bathhouse, or waiting room.\n\n(b) Keeping maps current. All maps shall be kept up-to-date and any change in route of travel, location of doors, location of refuge alternatives, or direction of airflow shall be shown on the maps by the end of the shift on which the change is made.\n\n(c) Informing affected miners. Miners underground on a shift when any such change is made shall be notified immediately of the change and other affected miners shall be informed of the change before entering the underground areas of the mine.\n\n[71 FR 71452, Dec. 8, 2006, as amended at 73 FR 80698, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":1},{"chapter":"I","heading":"Mine map.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-M/section-75.1200","part":"75","subchapter":"O","subpart":"M","id":"75.1200","citation":"30 CFR 75.1200","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.904","heading":"Identification of circuit breakers.","id":"75.904","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-J/section-75.904","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"J","subpartHeading":"Subpart J—Underground Low- and Medium-Voltage Alternating Current Circuits","text":"[Statutory Provisions]\n\nCircuit breakers shall be marked for identification.","occurrenceCount":1},{"chapter":"I","heading":"Identification of circuit breakers.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-J/section-77.904","part":"77","subchapter":"O","subpart":"J","id":"77.904","citation":"30 CFR 77.904","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403-8","heading":"Criteria—Track haulage roads.","id":"75.1403-8","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403-8","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"(a) The speed at which haulage equipment is operated should be determined by the condition of the roadbed, rails, rail joints, switches, frogs, and other elements of the track and the type and condition of the haulage equipment.\n\n(b) Track haulage roads should have a continuous clearance on one side of at least 24 inches from the farthest projection of normal traffic. Where it is necessary to change the side on which clearance is provided, 24 inches of clearance should be provided on both sides for a distance of not less than 100 feet and warning signs should be posted at such locations.\n\n(c) Track haulage roads developed after March 30, 1970, should have clearance on the “tight” side of at least 12 inches from the farthest projection of normal traffic. A minimum clearance of 6 inches should be maintained on the “tight” side of all track haulage roads developed prior to March 30, 1970.\n\n(d) The clearance space on all track haulage roads should be kept free of loose rock, supplies, and other loose materials.\n\n(e) Positive stopblocks or derails should be installed on all tracks near the top and at landings of shafts, slopes, and surface inclines.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1722","heading":"Mechanical equipment guards.","id":"75.1722","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1722","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-3","heading":"Condition and examination of firefighting equipment.","id":"75.1100-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"All firefighting equipment shall be maintained in a usable and operative condition. Chemical extinguishers shall be examined every 6 months and the date of the examination shall be written on a permanent tag attached to the extinguisher.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4608902","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}