{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4608864","name":"TUNNEL RIDGE MINE","status":"Active","status_date":"2010-07-26","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Ohio","nearest_town":"Valley Grove","operator_id":"P24507","operator_name":"Tunnel Ridge, LLC","controller_id":"C15455","controller_name":"Alliance Resource Partners LP","district":"C03","office":"St. Clairsville OH Field Office","employees":461,"latitude":40.096111,"longitude":-80.587222},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":32454},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4608864","name":"TUNNEL RIDGE MINE"},"operator":{"type":"operator","id":"P24507","name":"Tunnel Ridge, LLC"},"controller":{"type":"controller","id":"C15455","name":"Alliance Resource Partners LP"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24507","name":"Tunnel Ridge, LLC"},"object":{"type":"mine","id":"4608864","name":"TUNNEL RIDGE MINE"},"validFrom":"2000-11-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608864|P24507|2000-11-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15455","name":"Alliance Resource Partners LP"},"object":{"type":"mine","id":"4608864","name":"TUNNEL RIDGE MINE"},"validFrom":"2000-11-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608864|C15455|2000-11-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15455","name":"Alliance Resource Partners LP"},"object":{"type":"operator","id":"P24507","name":"Tunnel Ridge, LLC"},"validFrom":"2000-11-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4608864","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608864|P24507|2000-11-01|C15455|2000-11-01|95659"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":511,"firstDate":"2009-02-04","lastDate":"2026-09-04","metrics":{"daysLost":16327,"injuries":474,"fatalities":1,"recentRows":206,"restrictedDays":632,"contractorRecords":115},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"55458","DOCUMENT_NO":"220262530005","ACCIDENT_DT":"09/04/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The affected employee was assisting in the construction of a block wall when it collapsed as a coworker attempted to wedge the structure to the mine roof, striking the employee's lower leg with a falling block.","sourceDate":"2026-09-04"},{"SOURCE_ROW_NUMBER":"193093","DOCUMENT_NO":"220262530003","ACCIDENT_DT":"09/03/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"Wood beams stacked against belt structure fell, striking employee in the back and lower legs.","sourceDate":"2026-09-03"},{"SOURCE_ROW_NUMBER":"102631","DOCUMENT_NO":"220262320010","ACCIDENT_DT":"08/10/2026","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"An unintentional roof fall measuring 40' long by 16' wide by 7' above anchorage occurred in the East Mains #3 return entry at 23 1/2 crosscut.","sourceDate":"2026-08-10"},{"SOURCE_ROW_NUMBER":"85585","DOCUMENT_NO":"220262120002","ACCIDENT_DT":"07/27/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was jackhammering and went to push the coal forward after digging down. When EE leaned forward a fellow employee was lifting EE's shovel at the same time and hit the employee above EE's left eyebrow, cutting it open and knocking EE's hard hat off.","sourceDate":"2026-07-27"},{"SOURCE_ROW_NUMBER":"184574","DOCUMENT_NO":"220261940015","ACCIDENT_DT":"07/08/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Front-end loader operator","NO_INJURIES":"1","DAYS_LOST":"51","NARRATIVE":"Employee suffered injuries to the top of EE's left foot and toes when a piece of stone fell from the rib and penetrated EE's leather mining boot just behind the steel toe.","sourceDate":"2026-07-08"},{"SOURCE_ROW_NUMBER":"253428","DOCUMENT_NO":"220261900054","ACCIDENT_DT":"07/06/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The employee was prying on the tailgate spray arm jack cover with a pick hammer and the hammer slipped off of the cover and struck them on the top of the left hand.","sourceDate":"2026-07-06"},{"SOURCE_ROW_NUMBER":"29700","DOCUMENT_NO":"220261900052","ACCIDENT_DT":"07/05/2026","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"An unintentional roof fall measuring 16' long by 8' wide by 6.5' above anchorage occurred in the East Mains #1 track entry at 62 crosscut.","sourceDate":"2026-07-05"},{"SOURCE_ROW_NUMBER":"51163","DOCUMENT_NO":"220261900050","ACCIDENT_DT":"07/03/2026","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"An unintentional roof fall measuring 24' long by 16' wide by 6.5' above anchorage occurred in the East Mains #1 track entry at 20 crosscut.","sourceDate":"2026-07-03"},{"SOURCE_ROW_NUMBER":"274810","DOCUMENT_NO":"220261800016","ACCIDENT_DT":"06/19/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The employee was side bolting off the Joy full-face continuous miner. As they attempted to position a piece of welded-wire roof mesh over the machine, the mesh recoiled back and struck them above the left eye, just above their prescription safety glasses.","sourceDate":"2026-06-19"},{"SOURCE_ROW_NUMBER":"68321","DOCUMENT_NO":"220261490013","ACCIDENT_DT":"05/21/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"65","NARRATIVE":"On 5/20/26 a contract laborer experienced discomfort in EE's groin while helping pull 4\" HDPE pipe into a return entry.  On 5/21/26 EE was helping supply a section scoop and experienced more discomfort. EE was taken to a treatment center and diagnosed with a hernia.","sourceDate":"2026-05-21"},{"SOURCE_ROW_NUMBER":"124046","DOCUMENT_NO":"220261410015","ACCIDENT_DT":"05/14/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was using a 1 1/2 inch water line to fill a water buffalo. The pressure surged, propelling EE backwards against the rib causing a laceration to EE's finger.","sourceDate":"2026-05-14"},{"SOURCE_ROW_NUMBER":"137126","DOCUMENT_NO":"220261200008","ACCIDENT_DT":"04/15/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"37","NARRATIVE":"Employee was trying to install a replacement impact panel when it dropped, cut and smashed EE's right ring finger.","sourceDate":"2026-04-15"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2010-07-26","lastDate":"2010-07-26","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":3538,"firstDate":"2009-02-25","lastDate":"2026-08-13","metrics":{"ss":733,"delinquent":3259,"recentRows":663,"paidPenalty":1820005.99,"proposedPenalty":2077652,"currentAssessment":1830202},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"3030882","VIOLATION_NO":"9584965","ISSUE_DT":"08/13/2026","CFR_STANDARD_CD":"75.364(b)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-08-13"},{"SOURCE_ROW_NUMBER":"2984910","VIOLATION_NO":"9206871","ISSUE_DT":"08/13/2026","CFR_STANDARD_CD":"75.1002(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-08-13"},{"SOURCE_ROW_NUMBER":"2984916","VIOLATION_NO":"5122806","ISSUE_DT":"08/10/2026","CFR_STANDARD_CD":"72.630(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-08-10"},{"SOURCE_ROW_NUMBER":"2984908","VIOLATION_NO":"5122805","ISSUE_DT":"08/06/2026","CFR_STANDARD_CD":"75.1403-6(b)(3)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"366.00","CURRENT_ASSESSMENT_AMT":"366.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-08-06"},{"SOURCE_ROW_NUMBER":"2984907","VIOLATION_NO":"5122804","ISSUE_DT":"08/06/2026","CFR_STANDARD_CD":"75.1403-6(b)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-08-06"},{"SOURCE_ROW_NUMBER":"2984909","VIOLATION_NO":"5150264","ISSUE_DT":"08/05/2026","CFR_STANDARD_CD":"75.1403-8(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-08-05"},{"SOURCE_ROW_NUMBER":"2882969","VIOLATION_NO":"9253040","ISSUE_DT":"08/03/2026","CFR_STANDARD_CD":"75.1505(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"165.00","CURRENT_ASSESSMENT_AMT":"165.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-08-03"},{"SOURCE_ROW_NUMBER":"2984906","VIOLATION_NO":"5122803","ISSUE_DT":"07/29/2026","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-07-29"},{"SOURCE_ROW_NUMBER":"2882968","VIOLATION_NO":"9253037","ISSUE_DT":"07/29/2026","CFR_STANDARD_CD":"75.1101-7(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-07-29"},{"SOURCE_ROW_NUMBER":"2882967","VIOLATION_NO":"9253036","ISSUE_DT":"07/29/2026","CFR_STANDARD_CD":"75.380(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"165.00","CURRENT_ASSESSMENT_AMT":"165.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-07-29"},{"SOURCE_ROW_NUMBER":"2984915","VIOLATION_NO":"5122802","ISSUE_DT":"07/23/2026","CFR_STANDARD_CD":"75.337(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-07-23"},{"SOURCE_ROW_NUMBER":"2984905","VIOLATION_NO":"5122801","ISSUE_DT":"07/21/2026","CFR_STANDARD_CD":"75.1731(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-07-21"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":319,"firstDate":"2010-11-12","lastDate":"2026-08-07","metrics":{"appeals":0,"decisions":316,"recentRows":21,"decisionPenalty":587611,"originalPenalty":913801},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"461306","VIOLATION_NO":"9934020","DOCKET_NO":"PENN 2026-0031","DECISION_DT":"08/07/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"549.00","DECISION_PENALTY_AMT":"151.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-08-07"},{"SOURCE_ROW_NUMBER":"460213","VIOLATION_NO":"9938724","DOCKET_NO":"PENN 2026-0016","DECISION_DT":"06/15/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"366.00","DECISION_PENALTY_AMT":"151.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-06-15"},{"SOURCE_ROW_NUMBER":"460212","VIOLATION_NO":"9938716","DOCKET_NO":"PENN 2026-0016","DECISION_DT":"06/15/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"818.00","DECISION_PENALTY_AMT":"165.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-06-15"},{"SOURCE_ROW_NUMBER":"167729","VIOLATION_NO":"9936298","DOCKET_NO":"PENN 2026-0016","DECISION_DT":"06/15/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"10569.00","DECISION_PENALTY_AMT":"3441.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-06-15"},{"SOURCE_ROW_NUMBER":"453213","VIOLATION_NO":"9589854","DOCKET_NO":"WEVA 2025-0056","DECISION_DT":"07/24/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2644.00","DECISION_PENALTY_AMT":"861.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Young","sourceDate":"2025-07-24"},{"SOURCE_ROW_NUMBER":"452119","VIOLATION_NO":"9930270","DOCKET_NO":"WEVA 2025-0056","DECISION_DT":"07/24/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1287.00","DECISION_PENALTY_AMT":"773.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Young","sourceDate":"2025-07-24"},{"SOURCE_ROW_NUMBER":"164233","VIOLATION_NO":"9930742","DOCKET_NO":"WEVA 2025-0196","DECISION_DT":"07/08/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"935.00","DECISION_PENALTY_AMT":"147.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2025-07-08"},{"SOURCE_ROW_NUMBER":"164099","VIOLATION_NO":"9930738","DOCKET_NO":"WEVA 2025-0196","DECISION_DT":"07/08/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"935.00","DECISION_PENALTY_AMT":"280.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2025-07-08"},{"SOURCE_ROW_NUMBER":"443264","VIOLATION_NO":"9585702","DOCKET_NO":"WEVA 2024-0026","DECISION_DT":"05/16/2024","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"6688.00","DECISION_PENALTY_AMT":"6688.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2024-05-16"},{"SOURCE_ROW_NUMBER":"443002","VIOLATION_NO":"9585703","DOCKET_NO":"WEVA 2024-0026","DECISION_DT":"05/16/2024","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2014.00","DECISION_PENALTY_AMT":"2014.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2024-05-16"},{"SOURCE_ROW_NUMBER":"157569","VIOLATION_NO":"9585704","DOCKET_NO":"WEVA 2024-0026","DECISION_DT":"05/16/2024","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2014.00","DECISION_PENALTY_AMT":"2014.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2024-05-16"},{"SOURCE_ROW_NUMBER":"157417","VIOLATION_NO":"9585701","DOCKET_NO":"WEVA 2024-0026","DECISION_DT":"05/16/2024","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4139.00","DECISION_PENALTY_AMT":"905.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2024-05-16"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":11001,"firstDate":"2009-06-17","lastDate":"2026-10-08","metrics":{"recentRows":4973,"cpdmSamples":7399,"voidSamples":1955,"validSamples":9046,"maxConcentration":41.349,"concentrationTotal":5803.679},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2859233","SMP_TAKEN_DT":"10/8/2026","CONC":".214","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2603334","SMP_TAKEN_DT":"10/8/2026","CONC":".328","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2859005","SMP_TAKEN_DT":"10/7/2026","CONC":".275","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2517766","SMP_TAKEN_DT":"10/7/2026","CONC":".12","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2262193","SMP_TAKEN_DT":"10/7/2026","CONC":".242","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"1836681","SMP_TAKEN_DT":"10/7/2026","CONC":".222","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"1836203","SMP_TAKEN_DT":"10/7/2026","CONC":".274","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"1751285","SMP_TAKEN_DT":"10/7/2026","CONC":".188","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2943534","SMP_TAKEN_DT":"10/6/2026","CONC":".19","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2517101","SMP_TAKEN_DT":"10/6/2026","CONC":".208","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2432037","SMP_TAKEN_DT":"10/6/2026","CONC":".64","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"1921034","SMP_TAKEN_DT":"10/6/2026","CONC":".222","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":45,"firstDate":"2010-03-11","lastDate":"2026-04-30","metrics":{"linkedIssuances":45},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":319,"firstDate":"2009-06-17","lastDate":"2026-04-30","metrics":{"decisions":316,"ssChanged":102,"recentRows":24,"decisionPenalty":587611,"proposedPenalty":917682},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"280258","CITATION_NO":"9939111","CITATION_ISSUE_DT":"04/30/2026","DOCKET_NO":"PENN 2026-0079","CFR_STANDARD_CODE":"77.1713(a)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1818.00","sourceDate":"2026-04-30"},{"SOURCE_ROW_NUMBER":"167400","CITATION_NO":"9939110","CITATION_ISSUE_DT":"04/30/2026","DOCKET_NO":"PENN 2026-0079","CFR_STANDARD_CODE":"77.204","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1818.00","sourceDate":"2026-04-30"},{"SOURCE_ROW_NUMBER":"54533","CITATION_NO":"9934020","CITATION_ISSUE_DT":"12/09/2025","DOCKET_NO":"PENN 2026-0031","DECISION_DT":"08/07/2026","CFR_STANDARD_CODE":"75.1505(b)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"549.00","DECISION_PENALTY_AMT":"151.00","sourceDate":"2025-12-09"},{"SOURCE_ROW_NUMBER":"391251","CITATION_NO":"9527694","CITATION_ISSUE_DT":"11/04/2025","DOCKET_NO":"PENN 2026-0072","CFR_STANDARD_CODE":"48.31(a)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"245.00","sourceDate":"2025-11-04"},{"SOURCE_ROW_NUMBER":"394064","CITATION_NO":"9938724","CITATION_ISSUE_DT":"09/29/2025","DOCKET_NO":"PENN 2026-0016","DECISION_DT":"06/15/2026","CFR_STANDARD_CODE":"75.1403-6(b)(3)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"366.00","DECISION_PENALTY_AMT":"151.00","sourceDate":"2025-09-29"},{"SOURCE_ROW_NUMBER":"221927","CITATION_NO":"9936298","CITATION_ISSUE_DT":"09/10/2025","DOCKET_NO":"PENN 2026-0016","DECISION_DT":"06/15/2026","CFR_STANDARD_CODE":"75.380(d)(7)(iv)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"10569.00","DECISION_PENALTY_AMT":"3441.00","sourceDate":"2025-09-10"},{"SOURCE_ROW_NUMBER":"167796","CITATION_NO":"9938716","CITATION_ISSUE_DT":"09/03/2025","DOCKET_NO":"PENN 2026-0016","DECISION_DT":"06/15/2026","CFR_STANDARD_CODE":"75.363(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"818.00","DECISION_PENALTY_AMT":"165.00","sourceDate":"2025-09-03"},{"SOURCE_ROW_NUMBER":"393521","CITATION_NO":"9930742","CITATION_ISSUE_DT":"12/11/2024","DOCKET_NO":"WEVA 2025-0196","DECISION_DT":"07/08/2025","CFR_STANDARD_CODE":"75.1002(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"935.00","DECISION_PENALTY_AMT":"147.00","sourceDate":"2024-12-11"},{"SOURCE_ROW_NUMBER":"449840","CITATION_NO":"9930738","CITATION_ISSUE_DT":"11/26/2024","DOCKET_NO":"WEVA 2025-0196","DECISION_DT":"07/08/2025","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"935.00","DECISION_PENALTY_AMT":"280.00","sourceDate":"2024-11-26"},{"SOURCE_ROW_NUMBER":"51901","CITATION_NO":"9930270","CITATION_ISSUE_DT":"07/22/2024","DOCKET_NO":"WEVA 2025-0056","DECISION_DT":"07/24/2025","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1287.00","DECISION_PENALTY_AMT":"773.00","sourceDate":"2024-07-22"},{"SOURCE_ROW_NUMBER":"165708","CITATION_NO":"9589854","CITATION_ISSUE_DT":"03/20/2024","DOCKET_NO":"WEVA 2025-0056","DECISION_DT":"07/24/2025","CFR_STANDARD_CODE":"75.1725(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2644.00","DECISION_PENALTY_AMT":"861.00","sourceDate":"2024-03-20"},{"SOURCE_ROW_NUMBER":"391189","CITATION_NO":"9585703","CITATION_ISSUE_DT":"07/25/2023","DOCKET_NO":"WEVA 2024-0026","DECISION_DT":"05/16/2024","CFR_STANDARD_CODE":"75.313(c)(2)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"2014.00","DECISION_PENALTY_AMT":"2014.00","sourceDate":"2023-07-25"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":8286,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":44,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":1865,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":43,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"2000-11-01","lastDate":"2000-11-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":1588,"firstDate":"2006-06-28","lastDate":"2026-10-08","metrics":{"inspectors":2505,"recentRows":612,"onSiteHours":41894.75,"inspectionHours":65539.25,"inspectionSamples":2899},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"220205","EVENT_NO":"F038EFC","INSPECTION_BEGIN_DT":"10/08/2026","INSPECTION_END_DT":"10/08/2026","ACTIVITY_CODE":"E22","ACTIVITY":"Health Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.5","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"234844","EVENT_NO":"F015674","INSPECTION_BEGIN_DT":"10/07/2026","INSPECTION_END_DT":"10/07/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"825021","EVENT_NO":"F015673","INSPECTION_BEGIN_DT":"10/05/2026","INSPECTION_END_DT":"10/05/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"151540","EVENT_NO":"F015672","INSPECTION_BEGIN_DT":"10/01/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"39","SUM_TOTAL_ON_SITE_HOURS":"17","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"612193","EVENT_NO":"F026A92","INSPECTION_BEGIN_DT":"09/30/2026","INSPECTION_END_DT":"09/30/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"2.75","sourceDate":"2026-09-30"},{"SOURCE_ROW_NUMBER":"266176","EVENT_NO":"F01823D","INSPECTION_BEGIN_DT":"09/23/2026","INSPECTION_END_DT":"09/23/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2026-09-23"},{"SOURCE_ROW_NUMBER":"14600","EVENT_NO":"F01823C","INSPECTION_BEGIN_DT":"09/16/2026","INSPECTION_END_DT":"09/16/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-09-16"},{"SOURCE_ROW_NUMBER":"1030621","EVENT_NO":"F01823B","INSPECTION_BEGIN_DT":"09/14/2026","INSPECTION_END_DT":"09/14/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2026-09-14"},{"SOURCE_ROW_NUMBER":"1094730","EVENT_NO":"F026A90","INSPECTION_BEGIN_DT":"09/06/2026","INSPECTION_END_DT":"09/06/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"8.5","sourceDate":"2026-09-06"},{"SOURCE_ROW_NUMBER":"981849","EVENT_NO":"F038F00","INSPECTION_BEGIN_DT":"09/03/2026","INSPECTION_END_DT":"09/03/2026","ACTIVITY_CODE":"E22","ACTIVITY":"Health Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"10.25","sourceDate":"2026-09-03"},{"SOURCE_ROW_NUMBER":"1048017","EVENT_NO":"F01823A","INSPECTION_BEGIN_DT":"09/01/2026","INSPECTION_END_DT":"09/01/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"1053232","EVENT_NO":"F018239","INSPECTION_BEGIN_DT":"08/27/2026","INSPECTION_END_DT":"08/27/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-08-27"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":283,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2026-Q2":{"hours":277080,"employees":545,"production":1914333},"2026-Q1":{"hours":292227,"employees":569,"production":1593884},"2025-Q4":{"hours":278836,"employees":459,"production":1252815},"2025-Q3":{"hours":288485,"employees":475,"production":1509834},"2025-Q2":{"hours":277556,"employees":473,"production":1249332},"2025-Q1":{"hours":295945,"employees":495,"production":1236037},"2024-Q4":{"hours":279286,"employees":487,"production":1285825},"2024-Q3":{"hours":303224,"employees":504,"production":1410457},"2024-Q2":{"hours":304383,"employees":492,"production":1589383},"2024-Q1":{"hours":290927,"employees":479,"production":1744662},"2023-Q4":{"hours":284657,"employees":472,"production":1686939},"2023-Q3":{"hours":282963,"employees":483,"production":1980641}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":72,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017":{"hours":972430,"employees":438,"production":6988112},"2018":{"hours":987460,"employees":433,"production":6807214},"2019":{"hours":995190,"employees":446,"production":7330458},"2020":{"hours":896290,"employees":439,"production":6756696},"2021":{"hours":931395,"employees":436,"production":7212501},"2022":{"hours":1020754,"employees":462,"production":8312644},"2023":{"hours":1142261,"employees":478,"production":7664330},"2024":{"hours":1177820,"employees":491,"production":6030327},"2025":{"hours":1140822,"employees":476,"production":5248018},"2026":{"hours":569307,"employees":558,"production":3508217}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":722,"firstDate":"2010-04-06","lastDate":"2026-09-10","metrics":{"recentRows":229,"doseOver100":210,"actDoseTotal":55553,"pelDoseTotal":40153},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"246905","EVENT_NO":"F01822E","SURVEY_DATE":"09/10/2026","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","ACT_DOSE_85":"101","PEL_DOSE_90":"75","SURVEY_TYPE":"I","sourceDate":"2026-09-10"},{"SOURCE_ROW_NUMBER":"246904","EVENT_NO":"F01822E","SURVEY_DATE":"09/10/2026","OCCUPATION_CD_DESC":"LOADING MACHINE OPERATOR","MACHINE_CD":"24","ACT_DOSE_85":"66","PEL_DOSE_90":"47","SURVEY_TYPE":"I","sourceDate":"2026-09-10"},{"SOURCE_ROW_NUMBER":"246903","EVENT_NO":"F01822E","SURVEY_DATE":"09/10/2026","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"77","PEL_DOSE_90":"60","SURVEY_TYPE":"I","sourceDate":"2026-09-10"},{"SOURCE_ROW_NUMBER":"246902","EVENT_NO":"F01822E","SURVEY_DATE":"09/10/2026","OCCUPATION_CD_DESC":"ROOF BOLTER (MOUNTED) (INTAKE SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"110","PEL_DOSE_90":"86","SURVEY_TYPE":"I","sourceDate":"2026-09-10"},{"SOURCE_ROW_NUMBER":"246901","EVENT_NO":"F01822E","SURVEY_DATE":"09/10/2026","OCCUPATION_CD_DESC":"ROOF BOLTER (MOUNTED) (RETURN SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"86","PEL_DOSE_90":"69","SURVEY_TYPE":"I","sourceDate":"2026-09-10"},{"SOURCE_ROW_NUMBER":"246920","EVENT_NO":"F038EEB","SURVEY_DATE":"06/05/2026","OCCUPATION_CD_DESC":"LONGWALL OPERATOR (HEADGATE SIDE)","MACHINE_CD":"27","ACT_DOSE_85":"67","PEL_DOSE_90":"51","SURVEY_TYPE":"I","sourceDate":"2026-06-05"},{"SOURCE_ROW_NUMBER":"246919","EVENT_NO":"F038EEB","SURVEY_DATE":"06/05/2026","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","ACT_DOSE_85":"43","PEL_DOSE_90":"30","SURVEY_TYPE":"I","sourceDate":"2026-06-05"},{"SOURCE_ROW_NUMBER":"246918","EVENT_NO":"F038EEB","SURVEY_DATE":"06/05/2026","OCCUPATION_CD_DESC":"JACK SETTER (LONGWALL)","MACHINE_CD":"40","ACT_DOSE_85":"77","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2026-06-05"},{"SOURCE_ROW_NUMBER":"246917","EVENT_NO":"F038EEB","SURVEY_DATE":"06/05/2026","OCCUPATION_CD_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","MACHINE_CD":"27","ACT_DOSE_85":"81","PEL_DOSE_90":"63","SURVEY_TYPE":"I","sourceDate":"2026-06-05"},{"SOURCE_ROW_NUMBER":"246916","EVENT_NO":"F038EEB","SURVEY_DATE":"06/05/2026","OCCUPATION_CD_DESC":"HEADGATE OPERATOR","MACHINE_CD":"40","ACT_DOSE_85":"91","PEL_DOSE_90":"62","SURVEY_TYPE":"I","sourceDate":"2026-06-05"},{"SOURCE_ROW_NUMBER":"246915","EVENT_NO":"F038EE3","SURVEY_DATE":"04/24/2026","OCCUPATION_CD_DESC":"ROOF BOLTER (MOUNTED) (RETURN SIDE)","MACHINE_CD":"06","ACT_DOSE_85":"78","PEL_DOSE_90":"49","SURVEY_TYPE":"I","sourceDate":"2026-04-24"},{"SOURCE_ROW_NUMBER":"246914","EVENT_NO":"F038EE3","SURVEY_DATE":"04/24/2026","OCCUPATION_CD_DESC":"LOADING MACHINE OPERATOR","MACHINE_CD":"24","ACT_DOSE_85":"67","PEL_DOSE_90":"41","SURVEY_TYPE":"I","sourceDate":"2026-04-24"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":313,"firstDate":"2011-05-19","lastDate":"2026-09-03","metrics":{"recentRows":165,"voidSamples":6,"maxQuartzPct":9.9,"validSamples":307,"quartzPctTotal":953.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"129631","CASSETTE_NO":"58602791","SAMPLE_DT":"09/03/2026","QUARTZ_MICROGRAMS":"0","OCC_CODE_DESC":"UTILITY MAN","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-03"},{"SOURCE_ROW_NUMBER":"145882","CASSETTE_NO":"58602775","SAMPLE_DT":"08/20/2026","QUARTZ_PCT":"02.0","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"ROOF BOLTER (MOUNTED) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-20"},{"SOURCE_ROW_NUMBER":"101747","CASSETTE_NO":"58602911","SAMPLE_DT":"08/20/2026","QUARTZ_PCT":"02.4","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-20"},{"SOURCE_ROW_NUMBER":"131300","CASSETTE_NO":"58599697","SAMPLE_DT":"08/12/2026","QUARTZ_PCT":"02.1","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"JACK SETTER (LONGWALL)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-12"},{"SOURCE_ROW_NUMBER":"90621","CASSETTE_NO":"58599752","SAMPLE_DT":"08/12/2026","QUARTZ_PCT":"01.5","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-12"},{"SOURCE_ROW_NUMBER":"121523","CASSETTE_NO":"58603091","SAMPLE_DT":"07/22/2026","QUARTZ_PCT":"04.4","QUARTZ_MICROGRAMS":"16","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-22"},{"SOURCE_ROW_NUMBER":"23602","CASSETTE_NO":"58603074","SAMPLE_DT":"07/22/2026","QUARTZ_PCT":"05.5","QUARTZ_MICROGRAMS":"21","OCC_CODE_DESC":"ROOF BOLTER (MOUNTED) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-22"},{"SOURCE_ROW_NUMBER":"154849","CASSETTE_NO":"58600119","SAMPLE_DT":"07/21/2026","QUARTZ_PCT":"06.5","QUARTZ_MICROGRAMS":"77","OCC_CODE_DESC":"ROOF BOLTER (MOUNTED) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-21"},{"SOURCE_ROW_NUMBER":"85409","CASSETTE_NO":"58600112","SAMPLE_DT":"07/21/2026","QUARTZ_PCT":"09.9","QUARTZ_MICROGRAMS":"44","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-21"},{"SOURCE_ROW_NUMBER":"90343","CASSETTE_NO":"58599837","SAMPLE_DT":"05/27/2026","QUARTZ_PCT":"02.5","QUARTZ_MICROGRAMS":"25","OCC_CODE_DESC":"ROOF BOLTER (MOUNTED) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-05-27"},{"SOURCE_ROW_NUMBER":"138906","CASSETTE_NO":"58561961","SAMPLE_DT":"05/15/2026","QUARTZ_PCT":"02.0","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"MECHANIC","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-05-15"},{"SOURCE_ROW_NUMBER":"86761","CASSETTE_NO":"58561862","SAMPLE_DT":"05/15/2026","QUARTZ_PCT":"01.8","QUARTZ_MICROGRAMS":"9","OCC_CODE_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-05-15"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":3589,"firstDate":"2009-02-25","lastDate":"2026-10-06","metrics":{"ss":733,"amountDue":1830202,"contested":5,"amountPaid":1820005.99,"recentRows":682,"section104d":29,"unterminated":3,"proposedPenalty":2077652},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2810827","VIOLATION_NO":"8045644","VIOLATION_ISSUE_DT":"10/06/2026","SIG_SUB":"N","PART_SECTION":"75.1505(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"34","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2810519","VIOLATION_NO":"5122815","VIOLATION_ISSUE_DT":"09/14/2026","SIG_SUB":"N","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/14/2026","CONTESTED_IND":"N","sourceDate":"2026-09-14"},{"SOURCE_ROW_NUMBER":"2810307","VIOLATION_NO":"5122814","VIOLATION_ISSUE_DT":"09/08/2026","SIG_SUB":"N","PART_SECTION":"75.1403-6(b)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/08/2026","CONTESTED_IND":"N","sourceDate":"2026-09-08"},{"SOURCE_ROW_NUMBER":"2810495","VIOLATION_NO":"9938029","VIOLATION_ISSUE_DT":"09/03/2026","SIG_SUB":"N","PART_SECTION":"77.1605(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/21/2026","CONTESTED_IND":"N","sourceDate":"2026-09-03"},{"SOURCE_ROW_NUMBER":"2810306","VIOLATION_NO":"5122813","VIOLATION_ISSUE_DT":"08/31/2026","SIG_SUB":"N","PART_SECTION":"75.1714-3(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/31/2026","CONTESTED_IND":"N","sourceDate":"2026-08-31"},{"SOURCE_ROW_NUMBER":"2810305","VIOLATION_NO":"5122807","VIOLATION_ISSUE_DT":"08/17/2026","SIG_SUB":"N","PART_SECTION":"75.1403-6(b)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/17/2026","CONTESTED_IND":"N","sourceDate":"2026-08-17"},{"SOURCE_ROW_NUMBER":"2810441","VIOLATION_NO":"9584965","VIOLATION_ISSUE_DT":"08/13/2026","SIG_SUB":"N","PART_SECTION":"75.364(b)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/25/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-08-13"},{"SOURCE_ROW_NUMBER":"2810309","VIOLATION_NO":"9206871","VIOLATION_ISSUE_DT":"08/13/2026","SIG_SUB":"N","PART_SECTION":"75.1002(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/13/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-08-13"},{"SOURCE_ROW_NUMBER":"2810432","VIOLATION_NO":"5122806","VIOLATION_ISSUE_DT":"08/10/2026","SIG_SUB":"N","PART_SECTION":"72.630(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/10/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-08-10"},{"SOURCE_ROW_NUMBER":"2810304","VIOLATION_NO":"5122805","VIOLATION_ISSUE_DT":"08/06/2026","SIG_SUB":"Y","PART_SECTION":"75.1403-6(b)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/06/2026","PROPOSED_PENALTY":"366","AMOUNT_DUE":"366","AMOUNT_PAID":"366","CONTESTED_IND":"N","sourceDate":"2026-08-06"},{"SOURCE_ROW_NUMBER":"2810303","VIOLATION_NO":"5122804","VIOLATION_ISSUE_DT":"08/06/2026","SIG_SUB":"N","PART_SECTION":"75.1403-6(b)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/06/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-08-06"},{"SOURCE_ROW_NUMBER":"2810308","VIOLATION_NO":"5150264","VIOLATION_ISSUE_DT":"08/05/2026","SIG_SUB":"N","PART_SECTION":"75.1403-8(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/05/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-08-05"}]}],"safety":{"href":"/api/v1/mines/4608864/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4608864/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":{"averageEmployees":491,"companyType":"Operating Subsidiary","components":[{"averageEmployees":491,"laborHours":1177820,"mineType":"Underground","productionTons":6030327}],"county":"Ohio","laborHours":1177820,"mineName":"Tunnel Ridge Mine","mineType":"Underground","mshaId":"4608864","operatingAddress":"878 Old Brick Rd, West Alexande, PA 15376","operatingCompany":"Tunnel Ridge, Llc","operationType":"Mine and Preparation Plant","productionTons":6030327,"reportedRows":1,"sourceUrl":"https://www.eia.gov/coal/data/public/xls/coalpublic2024.xlsx","state":"West Virginia (Northern)","status":"Active","supplyRegion":"Appalachia Northern","union":"","year":2024},"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1505","heading":"Escapeway maps.","id":"75.1505","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-P/section-75.1505","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"P","subpartHeading":"Subpart P—Mine Emergencies","text":"(a) Content and accessibility. An escapeway map shall show the designated escapeways from the working sections or the miners' work stations to the surface or the exits at the bottom of the shaft or slope, refuge alternatives, and SCSR storage locations. The escapeway map shall be posted or readily accessible for all miners—\n\n(1) In each working section;\n\n(2) In each area where mechanized mining equipment is being installed or removed;\n\n(3) At the refuge alternative; and\n\n(4) At a surface location of the mine where miners congregate, such as at the mine bulletin board, bathhouse, or waiting room.\n\n(b) Keeping maps current. All maps shall be kept up-to-date and any change in route of travel, location of doors, location of refuge alternatives, or direction of airflow shall be shown on the maps by the end of the shift on which the change is made.\n\n(c) Informing affected miners. Miners underground on a shift when any such change is made shall be notified immediately of the change and other affected miners shall be informed of the change before entering the underground areas of the mine.\n\n[71 FR 71452, Dec. 8, 2006, as amended at 73 FR 80698, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1725","heading":"Machinery and equipment; operation and maintenance.","id":"75.1725","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1725","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403-6","heading":"Criteria—Self-propelled personnel carriers.","id":"75.1403-6","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403-6","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"(a) Each self-propelled personnel carrier should:\n\n(1) Be provided with an audible warning device;\n\n(2) Be provided with a sealed-beam headlight, or its equivalent, on each end;\n\n(3) Be provided with reflectors on both ends and sides.\n\n(b) In addition, each track-mounted self-propelled personnel carrier should:\n\n(1) Be provided with a suitable lifting jack and bar, which shall be secured or carried in a tool compartment;\n\n(2) Be equipped with 2 separate and independent braking systems properly installed and well maintained;\n\n(3) Be equipped with properly installed and well-maintained sanding devices, except that personnel carriers (jitneys), which transport not more than 5 men, need not be equipped with such sanding device;\n\n(4) If an open type, be equipped with guards of sufficient strength and height to prevent personnel from being thrown from such carriers.","occurrenceCount":4},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","heading":"Self-rescue devices; inspection, testing, maintenance, repair, and recordkeeping.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-3","part":"75","subchapter":"O","subpart":"R","id":"75.1714-3","citation":"30 CFR 75.1714-3","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.364","heading":"Weekly examination.","id":"75.364","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.364","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Worked-out areas. (1) At least every 7 days, a certified person shall examine unsealed worked-out areas where no pillars have been recovered by traveling to the area of deepest penetration; measuring methane and oxygen concentrations and air quantities and making tests to determine if the air is moving in the proper direction in the area. The locations of measurement points where tests and measurements will be performed shall be included in the mine ventilation plan and shall be adequate in number and location to assure ventilation and air quality in the area. Air quantity measurements shall also be made where the air enters and leaves the worked-out area. An alternative method of evaluating the ventilation of the area may be approved in the ventilation plan.\n\n(2) At least every 7 days, a certified person shall evaluate the effectiveness of bleeder systems required by § 75.334 as follows:\n\n(i) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in its proper direction shall be made where air enters the worked-out area.\n\n(ii) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in the proper direction shall be made immediately before the air enters a return split of air.\n\n(iii) At least one entry of each set of bleeder entries used as part of a bleeder system under § 75.334 shall be traveled in its entirety. Measurements of methane and oxygen concentrations and air quantities and a test to determine if the air is moving in the proper direction shall be made at the measurement point locations specified in the mine ventilation plan to determine the effectiveness of the bleeder system.\n\n(iv) In lieu of the requirements of paragraphs (a)(2)(i) and (iii) of this section, an alternative method of evaluation may be specified in the ventilation plan provided the alternative method results in proper evaluation of the effectiveness of the bleeder system.\n\n(b) Hazardous conditions and violations of mandatory health or safety standards. At least every 7 days, an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(8) of this section shall be made by a certified person designated by the operator at the following locations:\n\n(1) In at least one entry of each intake air course, in its entirety, so that the entire air course is traveled.\n\n(2) In at least one entry of each return air course, in its entirety, so that the entire air course is traveled.\n\n(3) In each longwall or shortwall travelway in its entirety, so that the entire travelway is traveled.\n\n(4) At each seal along return and bleeder air courses and at each seal along intake air courses not examined under § 75.360(b)(5).\n\n(5) In each escapeway so that the entire escapeway is traveled.\n\n(6) On each working section not examined under § 75.360(b)(3) during the previous 7 days.\n\n(7) At each water pump not examined during a preshift examination conducted during the previous 7 days.\n\n(8) Weekly examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust; and\n\n(iv) § 75.1403—maintenance of off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) Measurements and tests. At least every 7 days, a certified person shall—\n\n(1) Determine the volume of air entering the main intakes and in each intake split;\n\n(2) Determine the volume of air and test for methane in the last open crosscut in any pair or set of developing entries or rooms, in the return of each split of air immediately before it enters the main returns, and where the air leaves the main returns; and\n\n(3) Test for methane in the return entry nearest each set of seals immediately after the air passes the seals.\n\n(d) Hazardous conditions shall be corrected immediately. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Any violation of the nine mandatory health or safety standards found during a weekly examination shall be corrected.\n\n(e) The weekly examination may be conducted at the same time as the preshift or on-shift examinations.\n\n(f) (1) The weekly examination is not required during any 7 day period in which no one enters any underground area of the mine.\n\n(2) Except for certified persons required to make examinations, no one shall enter any underground area of the mine if a weekly examination has not been completed within the previous 7 days.\n\n(g) Certification. The person making the weekly examinations shall certify by initials, date, and the time that the examination was made. Certifications and times shall appear at enough locations to show that the entire area has been examined.\n\n(h) Recordkeeping. At the completion of any shift during which a portion of a weekly examination is conducted, a record of the results of each weekly examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards found during each examination and their locations, the corrective action taken, and the results and location of air and methane measurements, shall be made. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the person making the examination or a person designated by the operator. If made by a person other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(i) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 77 FR 20715, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1002","heading":"Installation of electric equipment and conductors; permissibility.","id":"75.1002","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-K/section-75.1002","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"K","subpartHeading":"Subpart K—Trolley Wires and Trolley Feeder Wires","text":"(a) Electric equipment must be permissible and maintained in a permissible condition when such equipment is located within 150 feet of pillar workings or longwall faces.\n\n(b) Electric conductors and cables installed in or in by the last open crosscut or within 150 feet of pillar workings or longwall faces must be—\n\n(1) Shielded high-voltage cables supplying power to permissible longwall equipment;\n\n(2) Interconnecting conductors and cables of permissible longwall equipment;\n\n(3) Conductors and cables of intrinsically safe circuits; and\n\n(4) Cables and conductors supplying power to low- and medium-voltage permissible equipment.\n\n(5) Shielded high-voltage cables supplying power to permissible continuous mining machines.\n\n[67 FR 11004, Mar. 11, 2002, as amended at 75 FR 17553, Apr. 6, 2010]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 72.630","heading":"Drill dust control at underground areas of underground mines.","id":"72.630","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-72/subpart-E/section-72.630","part":"72","partHeading":"PART 72—HEALTH STANDARDS FOR COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Miscellaneous","text":"(a) Dust resulting from drilling in rock shall be controlled by use of permissible dust collectors, or by water, or water with a wetting agent, or by ventilation, or by any other method or device approved by the Secretary that is as effective in controlling the dust.\n\n(b) Dust collectors. Dust collectors shall be maintained in permissible and operating condition. Dust collectors approved under Part 33—Dust Collectors for Use in Connection with Rock Drilling in Coal Mines of this title or under Bureau of Mines Schedule 25B are permissible dust collectors for the purpose of this section.\n\n(c) Water control. Water used to control dust from drilling rock shall be applied through a hollow drill steel or stem or by the flooding of vertical drill holes in the floor.\n\n(d) Ventilation control. To adequately control dust from drilling rock, the air current shall be so directed that the dust is readily dispersed and carried away from the drill operator or any other miners in the area.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403-8","heading":"Criteria—Track haulage roads.","id":"75.1403-8","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403-8","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"(a) The speed at which haulage equipment is operated should be determined by the condition of the roadbed, rails, rail joints, switches, frogs, and other elements of the track and the type and condition of the haulage equipment.\n\n(b) Track haulage roads should have a continuous clearance on one side of at least 24 inches from the farthest projection of normal traffic. Where it is necessary to change the side on which clearance is provided, 24 inches of clearance should be provided on both sides for a distance of not less than 100 feet and warning signs should be posted at such locations.\n\n(c) Track haulage roads developed after March 30, 1970, should have clearance on the “tight” side of at least 12 inches from the farthest projection of normal traffic. A minimum clearance of 6 inches should be maintained on the “tight” side of all track haulage roads developed prior to March 30, 1970.\n\n(d) The clearance space on all track haulage roads should be kept free of loose rock, supplies, and other loose materials.\n\n(e) Positive stopblocks or derails should be installed on all tracks near the top and at landings of shafts, slopes, and surface inclines.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4608864","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}