{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4608855","name":"Mine No 24","status":"Abandoned and Sealed","status_date":"2005-07-12","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Boone","nearest_town":"Williams Mountain","operator_id":"P20124","operator_name":"Long Branch Energy","controller_id":"C13737","controller_name":"Long Branch Energy Corporation","district":"C04","office":"Madison WV Field Office","employees":0,"latitude":38.014444,"longitude":-81.655555},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":700},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4608855","name":"Mine No 24"},"operator":{"type":"operator","id":"P20124","name":"Long Branch Energy"},"controller":{"type":"controller","id":"C13737","name":"Long Branch Energy Corporation"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13737","name":"Long Branch Energy Corporation"},"object":{"type":"mine","id":"4608855","name":"Mine No 24"},"validFrom":"1989-03-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608855|C13737|1989-03-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P20124","name":"Long Branch Energy"},"object":{"type":"mine","id":"4608855","name":"Mine No 24"},"validFrom":"2000-10-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608855|P20124|2000-10-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13737","name":"Long Branch Energy Corporation"},"object":{"type":"operator","id":"P20124","name":"Long Branch Energy"},"validFrom":"2000-10-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4608855","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608855|P20124|2000-10-01|C13737|1989-03-01|90997"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":31,"firstDate":"2001-02-21","lastDate":"2005-03-31","metrics":{"daysLost":197,"injuries":20,"fatalities":0,"recentRows":0,"restrictedDays":293,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"270565","DOCUMENT_NO":"220050950022","ACCIDENT_DT":"03/31/2005","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE, evening shift scoop operator, received contusion and laceration of right hand when a rock fell from the roof and struck EE.","sourceDate":"2005-03-31"},{"SOURCE_ROW_NUMBER":"72597","DOCUMENT_NO":"220050630056","ACCIDENT_DT":"02/28/2005","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"FALL OCCURRED IN A FOUR WAY INTERSECTION WITH LOW COVER FORTY FEET FROM ACTIVE SECTION. THIS AREA IS NOT AN ESCAPE WING. ROCK IS 100' X 20' X 6-8' THICK. THIS AREA HAS BEEN BREAKERED OFF","sourceDate":"2005-02-28"},{"SOURCE_ROW_NUMBER":"188748","DOCUMENT_NO":"220050270001","ACCIDENT_DT":"01/26/2005","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Roof fall occurred in No. 4 entry 150 ft. inby spad No. 1511, 400ft. from active face.  The roof fall is 60 ft. long, 20 ft. wide and 6 to 8 ft. thick.  All entries are breakered off.  The roof is laminated and was bolted using No. 5 x by 48 in. resin grouted re-bar.","sourceDate":"2005-01-26"},{"SOURCE_ROW_NUMBER":"29687","DOCUMENT_NO":"220050180037","ACCIDENT_DT":"01/17/2005","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"The roof fall occured in No. 2 entry of South Mains near spad No. 87, 1900 feet from active face.  This area was developed in March 2001.  The fall measures 50 feet long by 20 feet wide and 6 foot thick.  All entrances to the fall are breakered off.","sourceDate":"2005-01-17"},{"SOURCE_ROW_NUMBER":"231891","DOCUMENT_NO":"220043570020","ACCIDENT_DT":"12/22/2004","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Roof fall occur in crosscut between No. 3 and No. 4 entries near spad No. 1802.  The rock is 35' long, 20' wide and 6' to 8' thick.  The area is near the outcrop with low cover, water is present in roof strata along with roof cracks.","sourceDate":"2004-12-22"},{"SOURCE_ROW_NUMBER":"270564","DOCUMENT_NO":"220042930014","ACCIDENT_DT":"10/15/2004","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Roof fall occured in a 3-way intersection 3000 feet from active face near spad 1033 in return air course.  The rock was 40 feet long by 20 feet wide and 5 feet thick.  The air course will be rerouted.","sourceDate":"2004-10-15"},{"SOURCE_ROW_NUMBER":"197342","DOCUMENT_NO":"220042750002","ACCIDENT_DT":"09/28/2004","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall occured on working section 001, Entry No. 4 near spad 1677.  The area is near outcrop, low cover, some water present in roof strata and some cracks present.  Miner was turning a right hand crosscut. The fall was 40 feet long by 20 feet wide and 5 to 6 feet thick.","sourceDate":"2004-09-28"},{"SOURCE_ROW_NUMBER":"98347","DOCUMENT_NO":"220041110013","ACCIDENT_DT":"04/19/2004","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall 20 feet wide, 40 feet long, 6 feet thick occured in No. 1 Entry, left off South Mains at Spad No. 1370, 1200 feet outby active working section.","sourceDate":"2004-04-19"},{"SOURCE_ROW_NUMBER":"236245","DOCUMENT_NO":"220040270017","ACCIDENT_DT":"01/19/2004","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"THE ROOF FALL MEASURED 20' X 55' X 8' AND WAS IN A 4 WAY INTERSECTION WITH WATER SEEPAGE THROUGH A SHALE IMMEDIATE ROOF. THE AREA HAD BEEN BOLTED WITH 48\" LONG 5/8\" DIA. FULLY GROUTED BOLTS W/ 8\" X 8\" X 1\" HOLE PLATES. THE AREA HAD ALSO BEEN SPOT BOLTED WITH 80\" LONG 3/4\" DIA. MECHANICALLY ANCHORED RESIN BOLTS. THE ENTRY IN AN INACTIVE PORTION OF THE MINE. NO DAMAGE TO EQUIP/PERSON","sourceDate":"2004-01-19"},{"SOURCE_ROW_NUMBER":"85583","DOCUMENT_NO":"220032930083","ACCIDENT_DT":"10/14/2003","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"12","NARRATIVE":"EE, THIRD SHIFT GENERAL LABORER, WAS IN PROCESS OF MOVING THE SECTION CONVEYOR BELT TRAINING ROLLER, LOCATED NEAR THE TAIL PIECE, WHEN HE INJURED HIS LOW BACK.","sourceDate":"2003-10-14"},{"SOURCE_ROW_NUMBER":"188747","DOCUMENT_NO":"220032670026","ACCIDENT_DT":"09/16/2003","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","NARRATIVE":"THE DAY SHIFT ROOF BOLTER OPERATOR WAS DRILLING A TEST HOLE IN THE INTERSECTION BETWEEN NO. 6 & NO. 7 ENTRIES NEAR SPAD # 1105 WHEN DRILL STEEL STRUCK HIS LEFT THUMB.","sourceDate":"2003-09-16"},{"SOURCE_ROW_NUMBER":"111209","DOCUMENT_NO":"220032650096","ACCIDENT_DT":"09/12/2003","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"THE ROOF FALL OCCURRED IN A FOUR WAY INTERSECTION. FALL IS 40'LONG X 20'WIDE X 6'THICK. FALL IS IN NO.2 ENTRY, 220'INBY SPAD NO.1042 ON #1 LEFT OFF SOUTH MAINS.","sourceDate":"2003-09-12"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2005-07-12","lastDate":"2005-07-12","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":78,"firstDate":"2001-02-06","lastDate":"2005-02-09","metrics":{"ss":32,"delinquent":71,"recentRows":0,"paidPenalty":8184,"proposedPenalty":8684,"currentAssessment":8184},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"801361","VIOLATION_NO":"7211908","ISSUE_DT":"02/09/2005","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"84.00","CURRENT_ASSESSMENT_AMT":"84.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-02-09"},{"SOURCE_ROW_NUMBER":"801360","VIOLATION_NO":"7211907","ISSUE_DT":"02/08/2005","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-02-08"},{"SOURCE_ROW_NUMBER":"801359","VIOLATION_NO":"7211894","ISSUE_DT":"01/20/2005","CFR_STANDARD_CD":"75.1403-6(b)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-01-20"},{"SOURCE_ROW_NUMBER":"801358","VIOLATION_NO":"7211886","ISSUE_DT":"01/06/2005","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"177.00","CURRENT_ASSESSMENT_AMT":"177.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-01-06"},{"SOURCE_ROW_NUMBER":"801357","VIOLATION_NO":"7211885","ISSUE_DT":"01/06/2005","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"177.00","CURRENT_ASSESSMENT_AMT":"177.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-01-06"},{"SOURCE_ROW_NUMBER":"801356","VIOLATION_NO":"7211884","ISSUE_DT":"01/06/2005","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-01-06"},{"SOURCE_ROW_NUMBER":"801355","VIOLATION_NO":"7211883","ISSUE_DT":"01/04/2005","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-01-04"},{"SOURCE_ROW_NUMBER":"801348","VIOLATION_NO":"7211880","ISSUE_DT":"12/16/2004","CFR_STANDARD_CD":"77.1605(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-12-16"},{"SOURCE_ROW_NUMBER":"801347","VIOLATION_NO":"7211879","ISSUE_DT":"12/16/2004","CFR_STANDARD_CD":"75.1200","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-12-16"},{"SOURCE_ROW_NUMBER":"801346","VIOLATION_NO":"7211878","ISSUE_DT":"12/09/2004","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-12-09"},{"SOURCE_ROW_NUMBER":"801345","VIOLATION_NO":"7211859","ISSUE_DT":"11/09/2004","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-11-09"},{"SOURCE_ROW_NUMBER":"801344","VIOLATION_NO":"7211858","ISSUE_DT":"11/09/2004","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"114.00","CURRENT_ASSESSMENT_AMT":"114.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-11-09"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":1,"firstDate":"2003-03-31","lastDate":"2003-03-31","metrics":{"appeals":0,"decisions":1,"recentRows":0,"decisionPenalty":2000,"originalPenalty":2500},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"482362","VIOLATION_NO":"7205583","DOCKET_NO":"WEVA20020170","DECISION_DT":"03/31/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2500.00","DECISION_PENALTY_AMT":"2000.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2003-03-31"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":239,"firstDate":"2001-01-29","lastDate":"2005-02-18","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":9,"validSamples":230,"maxConcentration":6.628,"concentrationTotal":216.584},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1146795","CASS_NUM":"50761137","SMP_TAKEN_DT":"2/18/2005","CONC":".937","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-18"},{"SOURCE_ROW_NUMBER":"1341145","CASS_NUM":"50746805","SMP_TAKEN_DT":"2/17/2005","CONC":"1.085","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-17"},{"SOURCE_ROW_NUMBER":"843491","CASS_NUM":"50761152","SMP_TAKEN_DT":"2/17/2005","CONC":".599","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-17"},{"SOURCE_ROW_NUMBER":"1499011","CASS_NUM":"50761151","SMP_TAKEN_DT":"2/16/2005","CONC":".667","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-16"},{"SOURCE_ROW_NUMBER":"981062","CASS_NUM":"50746895","SMP_TAKEN_DT":"2/16/2005","CONC":".784","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-16"},{"SOURCE_ROW_NUMBER":"585655","CASS_NUM":"50761136","SMP_TAKEN_DT":"2/16/2005","CONC":"1.584","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-16"},{"SOURCE_ROW_NUMBER":"1453631","CASS_NUM":"57502345","SMP_TAKEN_DT":"2/8/2005","CONC":".309","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-08"},{"SOURCE_ROW_NUMBER":"1380804","CASS_NUM":"57502276","SMP_TAKEN_DT":"2/8/2005","CONC":".334","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ELECTRICIAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-08"},{"SOURCE_ROW_NUMBER":"1089086","CASS_NUM":"57502369","SMP_TAKEN_DT":"2/8/2005","CONC":".689","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-08"},{"SOURCE_ROW_NUMBER":"796001","CASS_NUM":"57502337","SMP_TAKEN_DT":"2/8/2005","CONC":".612","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-08"},{"SOURCE_ROW_NUMBER":"511691","CASS_NUM":"57502349","SMP_TAKEN_DT":"2/8/2005","CONC":"1.994","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-08"},{"SOURCE_ROW_NUMBER":"475515","CASS_NUM":"57502333","SMP_TAKEN_DT":"2/8/2005","CONC":".472","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-08"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":4,"firstDate":"2002-01-10","lastDate":"2005-03-22","metrics":{"linkedIssuances":4},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":87,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":21,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"2000-10-01","lastDate":"2000-10-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":46,"firstDate":"2000-12-13","lastDate":"2005-07-13","metrics":{"inspectors":65,"recentRows":0,"onSiteHours":816.5,"inspectionHours":1303.75,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"25451","EVENT_NO":"4108446","INSPECTION_BEGIN_DT":"07/13/2005","INSPECTION_END_DT":"07/25/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2005-07-13"},{"SOURCE_ROW_NUMBER":"695318","EVENT_NO":"4108434","INSPECTION_BEGIN_DT":"06/01/2005","INSPECTION_END_DT":"06/01/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2005-06-01"},{"SOURCE_ROW_NUMBER":"670023","EVENT_NO":"4108411","INSPECTION_BEGIN_DT":"01/03/2005","INSPECTION_END_DT":"02/28/2005","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"73.5","SUM_TOTAL_ON_SITE_HOURS":"47.5","sourceDate":"2005-01-03"},{"SOURCE_ROW_NUMBER":"803368","EVENT_NO":"4109179","INSPECTION_BEGIN_DT":"12/22/2004","INSPECTION_END_DT":"12/27/2004","ACTIVITY_CODE":"AFC","ACTIVITY":"NON-INJURY ACCIDENT INVESTIGATION","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"7.5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2004-12-22"},{"SOURCE_ROW_NUMBER":"206769","EVENT_NO":"4108409","INSPECTION_BEGIN_DT":"10/07/2004","INSPECTION_END_DT":"12/27/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"72","SUM_TOTAL_ON_SITE_HOURS":"47","sourceDate":"2004-10-07"},{"SOURCE_ROW_NUMBER":"995394","EVENT_NO":"4106193","INSPECTION_BEGIN_DT":"09/28/2004","INSPECTION_END_DT":"09/29/2004","ACTIVITY_CODE":"AFC","ACTIVITY":"NON-INJURY ACCIDENT INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2004-09-28"},{"SOURCE_ROW_NUMBER":"920720","EVENT_NO":"4109051","INSPECTION_BEGIN_DT":"08/24/2004","INSPECTION_END_DT":"08/25/2004","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2004-08-24"},{"SOURCE_ROW_NUMBER":"204501","EVENT_NO":"4109151","INSPECTION_BEGIN_DT":"07/09/2004","INSPECTION_END_DT":"09/30/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"75","SUM_TOTAL_ON_SITE_HOURS":"55.5","sourceDate":"2004-07-09"},{"SOURCE_ROW_NUMBER":"504305","EVENT_NO":"4107483","INSPECTION_BEGIN_DT":"05/18/2004","INSPECTION_END_DT":"05/19/2004","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"0","SUM_TOTAL_INSP_HOURS":"0","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2004-05-18"},{"SOURCE_ROW_NUMBER":"774965","EVENT_NO":"4107475","INSPECTION_BEGIN_DT":"04/01/2004","INSPECTION_END_DT":"06/30/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"47","SUM_TOTAL_ON_SITE_HOURS":"31.5","sourceDate":"2004-04-01"},{"SOURCE_ROW_NUMBER":"688898","EVENT_NO":"4104925","INSPECTION_BEGIN_DT":"02/25/2004","INSPECTION_END_DT":"02/26/2004","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.5","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2004-02-25"},{"SOURCE_ROW_NUMBER":"658721","EVENT_NO":"4107453","INSPECTION_BEGIN_DT":"01/20/2004","INSPECTION_END_DT":"03/29/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"90","SUM_TOTAL_ON_SITE_HOURS":"65.75","sourceDate":"2004-01-20"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":58,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2005-Q3":{"hours":0,"employees":0,"production":0},"2005-Q2":{"hours":2147,"employees":5,"production":0},"2005-Q1":{"hours":22083,"employees":34,"production":88626},"2004-Q4":{"hours":23520,"employees":37,"production":74965},"2004-Q3":{"hours":22200,"employees":35,"production":94945},"2004-Q2":{"hours":20956,"employees":34,"production":79596},"2004-Q1":{"hours":23781,"employees":35,"production":199100},"2003-Q4":{"hours":21925,"employees":35,"production":96085},"2003-Q3":{"hours":21240,"employees":36,"production":90966},"2003-Q2":{"hours":20302,"employees":32,"production":96390},"2003-Q1":{"hours":2915,"employees":11,"production":5516},"2002-Q4":{"hours":1090,"employees":2,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":14,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":315,"employees":3,"production":0},"2001":{"hours":80565,"employees":33,"production":345521},"2002":{"hours":28908,"employees":15,"production":129779},"2003":{"hours":66382,"employees":29,"production":288957},"2004":{"hours":90457,"employees":36,"production":448606},"2005":{"hours":24230,"employees":22,"production":88626}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":10,"firstDate":"2001-08-15","lastDate":"2004-05-18","metrics":{"recentRows":0,"doseOver100":6,"actDoseTotal":37931,"pelDoseTotal":30256},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"246148","EVENT_NO":"4107483","SURVEY_DATE":"05/18/2004","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"3470","PEL_DOSE_90":"1877","SURVEY_TYPE":"I","sourceDate":"2004-05-18"},{"SOURCE_ROW_NUMBER":"246147","EVENT_NO":"4107483","SURVEY_DATE":"05/18/2004","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"12010","PEL_DOSE_90":"10060","SURVEY_TYPE":"I","sourceDate":"2004-05-18"},{"SOURCE_ROW_NUMBER":"246146","EVENT_NO":"4107483","SURVEY_DATE":"05/18/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"12290","PEL_DOSE_90":"10050","SURVEY_TYPE":"I","sourceDate":"2004-05-18"},{"SOURCE_ROW_NUMBER":"246145","EVENT_NO":"4107483","SURVEY_DATE":"05/18/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"9670","PEL_DOSE_90":"7897","SURVEY_TYPE":"I","sourceDate":"2004-05-18"},{"SOURCE_ROW_NUMBER":"246144","EVENT_NO":"4107483","SURVEY_DATE":"05/18/2004","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"0","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2004-05-18"},{"SOURCE_ROW_NUMBER":"246143","EVENT_NO":"4095414","SURVEY_DATE":"08/15/2001","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"122","PEL_DOSE_90":"97","SURVEY_TYPE":"I","sourceDate":"2001-08-15"},{"SOURCE_ROW_NUMBER":"246142","EVENT_NO":"4095414","SURVEY_DATE":"08/15/2001","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"172","PEL_DOSE_90":"155","SURVEY_TYPE":"I","sourceDate":"2001-08-15"},{"SOURCE_ROW_NUMBER":"246141","EVENT_NO":"4095414","SURVEY_DATE":"08/15/2001","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"62","PEL_DOSE_90":"34","SURVEY_TYPE":"I","sourceDate":"2001-08-15"},{"SOURCE_ROW_NUMBER":"246140","EVENT_NO":"4095414","SURVEY_DATE":"08/15/2001","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"59","PEL_DOSE_90":"32","SURVEY_TYPE":"I","sourceDate":"2001-08-15"},{"SOURCE_ROW_NUMBER":"246139","EVENT_NO":"4095414","SURVEY_DATE":"08/15/2001","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"76","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2001-08-15"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":28,"firstDate":"2001-01-29","lastDate":"2005-02-08","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":13.4,"validSamples":28,"quartzPctTotal":165.8},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"164880","CASSETTE_NO":"57502349","SAMPLE_DT":"02/08/2005","QUARTZ_PCT":"04.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-02-08"},{"SOURCE_ROW_NUMBER":"34241","CASSETTE_NO":"57502217","SAMPLE_DT":"01/04/2005","QUARTZ_PCT":"03.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-01-04"},{"SOURCE_ROW_NUMBER":"99822","CASSETTE_NO":"57501990","SAMPLE_DT":"11/09/2004","QUARTZ_PCT":"05.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-11-09"},{"SOURCE_ROW_NUMBER":"41493","CASSETTE_NO":"57501995","SAMPLE_DT":"11/09/2004","QUARTZ_PCT":"05.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-11-09"},{"SOURCE_ROW_NUMBER":"158006","CASSETTE_NO":"57491286","SAMPLE_DT":"09/08/2004","QUARTZ_PCT":"05.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-09-08"},{"SOURCE_ROW_NUMBER":"99676","CASSETTE_NO":"57465169","SAMPLE_DT":"05/25/2004","QUARTZ_PCT":"06.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-05-25"},{"SOURCE_ROW_NUMBER":"48289","CASSETTE_NO":"50702401","SAMPLE_DT":"03/19/2004","QUARTZ_PCT":"04.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-03-19"},{"SOURCE_ROW_NUMBER":"65980","CASSETTE_NO":"50702344","SAMPLE_DT":"02/25/2004","QUARTZ_PCT":"05.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-02-25"},{"SOURCE_ROW_NUMBER":"80872","CASSETTE_NO":"57454759","SAMPLE_DT":"02/10/2004","QUARTZ_PCT":"05.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-02-10"},{"SOURCE_ROW_NUMBER":"56513","CASSETTE_NO":"50702223","SAMPLE_DT":"01/26/2004","QUARTZ_PCT":"04.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-01-26"},{"SOURCE_ROW_NUMBER":"105499","CASSETTE_NO":"50706145","SAMPLE_DT":"01/09/2004","QUARTZ_PCT":"03.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-01-09"},{"SOURCE_ROW_NUMBER":"168342","CASSETTE_NO":"57454686","SAMPLE_DT":"12/22/2003","QUARTZ_PCT":"07.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-12-22"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":80,"firstDate":"2001-02-06","lastDate":"2005-02-09","metrics":{"ss":33,"amountDue":8184,"contested":1,"amountPaid":8184,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":8684},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2806868","VIOLATION_NO":"7211908","VIOLATION_ISSUE_DT":"02/09/2005","SIG_SUB":"Y","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/10/2005","PROPOSED_PENALTY":"84","AMOUNT_DUE":"84","AMOUNT_PAID":"84","CONTESTED_IND":"N","sourceDate":"2005-02-09"},{"SOURCE_ROW_NUMBER":"2806867","VIOLATION_NO":"7211907","VIOLATION_ISSUE_DT":"02/08/2005","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/08/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-02-08"},{"SOURCE_ROW_NUMBER":"2806866","VIOLATION_NO":"7211894","VIOLATION_ISSUE_DT":"01/20/2005","SIG_SUB":"N","PART_SECTION":"75.1403-6(b)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/20/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-01-20"},{"SOURCE_ROW_NUMBER":"2806865","VIOLATION_NO":"7211886","VIOLATION_ISSUE_DT":"01/06/2005","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/10/2005","PROPOSED_PENALTY":"177","AMOUNT_DUE":"177","AMOUNT_PAID":"177","CONTESTED_IND":"N","sourceDate":"2005-01-06"},{"SOURCE_ROW_NUMBER":"2806864","VIOLATION_NO":"7211885","VIOLATION_ISSUE_DT":"01/06/2005","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/10/2005","PROPOSED_PENALTY":"177","AMOUNT_DUE":"177","AMOUNT_PAID":"177","CONTESTED_IND":"N","sourceDate":"2005-01-06"},{"SOURCE_ROW_NUMBER":"2806863","VIOLATION_NO":"7211884","VIOLATION_ISSUE_DT":"01/06/2005","SIG_SUB":"N","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/06/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-01-06"},{"SOURCE_ROW_NUMBER":"2806862","VIOLATION_NO":"7211883","VIOLATION_ISSUE_DT":"01/04/2005","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/04/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-01-04"},{"SOURCE_ROW_NUMBER":"2806914","VIOLATION_NO":"7211880","VIOLATION_ISSUE_DT":"12/16/2004","SIG_SUB":"N","PART_SECTION":"77.1605(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/16/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-12-16"},{"SOURCE_ROW_NUMBER":"2806913","VIOLATION_NO":"7211879","VIOLATION_ISSUE_DT":"12/16/2004","SIG_SUB":"N","PART_SECTION":"75.1200","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/22/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-12-16"},{"SOURCE_ROW_NUMBER":"2806912","VIOLATION_NO":"7211878","VIOLATION_ISSUE_DT":"12/09/2004","SIG_SUB":"N","PART_SECTION":"75.1100-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/09/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-12-09"},{"SOURCE_ROW_NUMBER":"2806911","VIOLATION_NO":"7211859","VIOLATION_ISSUE_DT":"11/09/2004","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/09/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-11-09"},{"SOURCE_ROW_NUMBER":"2806910","VIOLATION_NO":"7211858","VIOLATION_ISSUE_DT":"11/09/2004","SIG_SUB":"Y","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/09/2004","PROPOSED_PENALTY":"114","AMOUNT_DUE":"114","AMOUNT_PAID":"114","CONTESTED_IND":"N","sourceDate":"2004-11-09"}]}],"safety":{"href":"/api/v1/mines/4608855/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4608855/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403-6","heading":"Criteria—Self-propelled personnel carriers.","id":"75.1403-6","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403-6","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"(a) Each self-propelled personnel carrier should:\n\n(1) Be provided with an audible warning device;\n\n(2) Be provided with a sealed-beam headlight, or its equivalent, on each end;\n\n(3) Be provided with reflectors on both ends and sides.\n\n(b) In addition, each track-mounted self-propelled personnel carrier should:\n\n(1) Be provided with a suitable lifting jack and bar, which shall be secured or carried in a tool compartment;\n\n(2) Be equipped with 2 separate and independent braking systems properly installed and well maintained;\n\n(3) Be equipped with properly installed and well-maintained sanding devices, except that personnel carriers (jitneys), which transport not more than 5 men, need not be equipped with such sanding device;\n\n(4) If an open type, be equipped with guards of sufficient strength and height to prevent personnel from being thrown from such carriers.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1725","heading":"Machinery and equipment; operation and maintenance.","id":"75.1725","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1725","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","heading":"Mine map.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-M/section-75.1200","part":"75","subchapter":"O","subpart":"M","id":"75.1200","citation":"30 CFR 75.1200","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-3","heading":"Condition and examination of firefighting equipment.","id":"75.1100-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"All firefighting equipment shall be maintained in a usable and operative condition. Chemical extinguishers shall be examined every 6 months and the date of the examination shall be written on a permanent tag attached to the extinguisher.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4608855","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}