{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4608831","name":"Ceredo Synfuel Plant","status":"Abandoned","status_date":"2011-06-20","mine_type":"Facility","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Wayne","nearest_town":"Ceredo","operator_id":"P24365","operator_name":"Ceredo Synfuel LLC","controller_id":"C16016","controller_name":"Progress Energy Inc","district":"C04","office":"Beckley District","employees":0,"latitude":38.398333,"longitude":-82.549166},"coverage":{"contributingSources":13,"registeredSources":20,"sourceRows":384},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4608831","name":"Ceredo Synfuel Plant"},"operator":{"type":"operator","id":"P24365","name":"Ceredo Synfuel LLC"},"controller":{"type":"controller","id":"C16016","name":"Progress Energy Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24365","name":"Ceredo Synfuel LLC"},"object":{"type":"mine","id":"4608831","name":"Ceredo Synfuel Plant"},"validFrom":"2000-04-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608831|P24365|2000-04-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C14045","name":"Florida Progress Corporation"},"object":{"type":"mine","id":"4608831","name":"Ceredo Synfuel Plant"},"validFrom":"2000-04-01","validTo":"2003-06-15","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608831|C14045|2000-04-01|2003-06-15"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14045","name":"Florida Progress Corporation"},"object":{"type":"operator","id":"P24365","name":"Ceredo Synfuel LLC"},"validFrom":"2000-04-01","validTo":"2003-06-15","current":false,"derived":true,"evidenceMineId":"4608831","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608831|P24365|2000-04-01|C14045|2000-04-01|91860"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C16016","name":"Progress Energy Inc"},"object":{"type":"mine","id":"4608831","name":"Ceredo Synfuel Plant"},"validFrom":"2003-06-16","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608831|C16016|2003-06-16|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C16016","name":"Progress Energy Inc"},"object":{"type":"operator","id":"P24365","name":"Ceredo Synfuel LLC"},"validFrom":"2003-06-16","validTo":null,"current":true,"derived":true,"evidenceMineId":"4608831","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608831|P24365|2000-04-01|C16016|2003-06-16|98052"}}],"coverage":{"historyRecords":2,"edgeCount":5,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":11,"firstDate":"2000-07-18","lastDate":"2007-12-07","metrics":{"daysLost":96,"injuries":11,"fatalities":0,"recentRows":0,"restrictedDays":28,"contractorRecords":1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"154424","DOCUMENT_NO":"220073460014","ACCIDENT_DT":"12/07/2007","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Warehouseman, Bagger, Palletizer/Stacker, Store keeper, Packager, Fabricator, Cleaning plant operator","NO_INJURIES":"1","DAYS_LOST":"21","NARRATIVE":"While walking to the Briquetter Building, employee stepped off of the pugmill concrete pad, which is approximately 6-8 inches above ground level and rolled his right ankle. This resulted in a sprained ankle and time off work.","sourceDate":"2007-12-07"},{"SOURCE_ROW_NUMBER":"38358","DOCUMENT_NO":"220052370009","ACCIDENT_DT":"08/23/2005","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Warehouseman, Bagger, Palletizer/Stacker, Store keeper, Packager, Fabricator, Cleaning plant operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was helping with general cleanup duties while his co-workers were eating lunch. The employee was using a high pressure water hose to wash down the pugmill feed belt. The high pressure water hose he was using slipped out of his hand and the hose nozzle struck him in the chin resulting in a laceration which required 6 stitches.","sourceDate":"2005-08-23"},{"SOURCE_ROW_NUMBER":"21101","DOCUMENT_NO":"220051390014","ACCIDENT_DT":"05/06/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Warehouseman, Bagger, Palletizer/Stacker, Store keeper, Packager, Fabricator, Cleaning plant operator","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"Ldr oper. was helping change out training roller. Employee tried to pick up roller by himself from the dollie without employee assistance. This resulted in an abdominal strain. Employee felt that he was alright, but he went to the doctor on 5/10, 1 of his 4 days off per his schedule. The Foreman didn't find out that the doctor wanted the employee off for 1 week, until 5/14.","sourceDate":"2005-05-06"},{"SOURCE_ROW_NUMBER":"68311","DOCUMENT_NO":"220042300007","ACCIDENT_DT":"08/07/2004","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Warehouseman, Bagger, Palletizer/Stacker, Store keeper, Packager, Fabricator, Cleaning plant operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was splicing a water hose with a banding tool. When he was finished, he pulled out what was left of the band. During the removal the extra band that was left in the banding tool, cut the left forearm of the employee.","sourceDate":"2004-08-07"},{"SOURCE_ROW_NUMBER":"132729","DOCUMENT_NO":"220042150021","ACCIDENT_DT":"07/27/2004","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Adjusting pin on trolley needed to be removed to provide a more secure fit to the structure beam. During the adjustment the trolley arm came loose from one end striking the employee in the left side of the cheek. The employee received nine stiches as a result of this accident. No lost time.","sourceDate":"2004-07-27"},{"SOURCE_ROW_NUMBER":"98341","DOCUMENT_NO":"220031610052","ACCIDENT_DT":"06/05/2003","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","NARRATIVE":"THE EE WERE MAKING ADJUSTMENTS TO A EXTRUSION ROLLER IN A SYNFUEL PELLETIZER. A SPECIAL WRENCHWAS USED TO BREAK LOOSE A LOCK NUT ON ADJUSTMENTSCREW. ON EE IS HOLDING WRENCH ON NUT OTHER EE APPLIES FORCE TO WRENCH HANDLE AS THE NUT BREAKSTHE LITTLE FINGER END IS CAUGHT IN A PINCH POINTSMASHING END OF FINGER.","sourceDate":"2003-06-05"},{"SOURCE_ROW_NUMBER":"231878","DOCUMENT_NO":"220030830196","ACCIDENT_DT":"03/12/2003","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Welder (shop)","NO_INJURIES":"1","NARRATIVE":"EE WAS CLEANING PAINT OFF THE FEEDER & FELL THROUGH A HOLE IN THE FLOOR THATS USED FOR A LADDER.AS EE FELL HE REACHED OUT TO CATCH HIMSELF & HEARD HIS SHOULDER POP.","sourceDate":"2003-03-12"},{"SOURCE_ROW_NUMBER":"262093","DOCUMENT_NO":"220011500003","ACCIDENT_DT":"05/28/2001","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Front-end loader, Scraper-loader operator, Pan operator, Payloader, Scraper rig operator","NO_INJURIES":"1","NARRATIVE":"EMPLOYEE DETECTED NOISE FROM OVERHEAD AIR CONDITIONER, IN CAB, HIS MIDDLE FINGER(R.H.) COMES IN CONTACT WITH FAN BLADE, CAUSING LACERATION TO FINGER, NEEDED STICHES.","sourceDate":"2001-05-28"},{"SOURCE_ROW_NUMBER":"59690","DOCUMENT_NO":"220010720038","ACCIDENT_DT":"03/07/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"74","NARRATIVE":"EE TURNED A CORNER OF BUILDING WHILE WALKING ON UNEVEN, SLOPING ASPHALT AND ENCOUNTERED AN ISOLATED PATCH OF BLACK ICE. HE LOST HIS BALANCE AND FELL, FRACTURING 2 BONES IN LOWER LEFT LEG.","sourceDate":"2001-03-07"},{"SOURCE_ROW_NUMBER":"132728","DOCUMENT_NO":"220003290032","ACCIDENT_DT":"11/16/2000","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Backhoe operator, Trackhoe operator, Crane operator","NO_INJURIES":"1","NARRATIVE":"THREE EMPLOYEES WERE CHANGING THE RETURN ROLLER.ONE LIFTING THE WEIGHT OF THE BELT, THE SECOND ALIGNING THE BRACKET, INJURED LIFTING ROLLER. THE ROLLER BECAME LODGED ON A GREASE FITTING AND HE REMOVED HIS HANDS TO DISCUSS A FURTHER PLAN OF ACTION WITH HIS COWORKERS. WHEN HE PUT HIS HANDSBACK UNDER THE ROLLER IT BECAME DISLODGED FROM THE GREASE FITTING PINNING HIS FINGER.","sourceDate":"2000-11-16"},{"SOURCE_ROW_NUMBER":"137114","DOCUMENT_NO":"220002060026","ACCIDENT_DT":"07/18/2000","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","NARRATIVE":"EE WAS CLEANING PLANT WITH A WATER HOSE (200/250 PSI), WHEN THE EE NOTCIED A DECREASE IN WATER PRESSURE. EE WRAPPED END OF HOSE AROUND HIS HAND AND WALKED TO RELEASE A KINK IN THE HOSE. EE, HA VING HOSE IN HAND, RELEASED THE KINK IN THE HOSE RELEASING LOST PRESSURE AND BINDING EE'S HAND, RESULTING IN INJURY TO EE'S FINGER.","sourceDate":"2000-07-18"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2011-06-20","lastDate":"2011-06-20","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":14,"firstDate":"2000-06-13","lastDate":"2007-09-05","metrics":{"ss":6,"delinquent":11,"recentRows":0,"paidPenalty":992,"proposedPenalty":992,"currentAssessment":992},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"829402","VIOLATION_NO":"7275809","ISSUE_DT":"09/05/2007","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"162.00","CURRENT_ASSESSMENT_AMT":"162.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-09-05"},{"SOURCE_ROW_NUMBER":"805610","VIOLATION_NO":"7258586","ISSUE_DT":"01/16/2007","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-01-16"},{"SOURCE_ROW_NUMBER":"785537","VIOLATION_NO":"7219614","ISSUE_DT":"10/28/2003","CFR_STANDARD_CD":"77.204","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"91.00","CURRENT_ASSESSMENT_AMT":"91.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-10-28"},{"SOURCE_ROW_NUMBER":"785536","VIOLATION_NO":"7219613","ISSUE_DT":"10/28/2003","CFR_STANDARD_CD":"77.205(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-10-28"},{"SOURCE_ROW_NUMBER":"785535","VIOLATION_NO":"7219612","ISSUE_DT":"10/20/2003","CFR_STANDARD_CD":"77.400(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-10-20"},{"SOURCE_ROW_NUMBER":"771340","VIOLATION_NO":"7188095","ISSUE_DT":"06/21/2001","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-06-21"},{"SOURCE_ROW_NUMBER":"754615","VIOLATION_NO":"7188025","ISSUE_DT":"11/02/2000","CFR_STANDARD_CD":"77.400(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"76.00","CURRENT_ASSESSMENT_AMT":"76.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-11-02"},{"SOURCE_ROW_NUMBER":"754614","VIOLATION_NO":"7188024","ISSUE_DT":"11/02/2000","CFR_STANDARD_CD":"77.400(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"76.00","CURRENT_ASSESSMENT_AMT":"76.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-11-02"},{"SOURCE_ROW_NUMBER":"754618","VIOLATION_NO":"7188019","ISSUE_DT":"10/23/2000","CFR_STANDARD_CD":"62.120","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-10-23"},{"SOURCE_ROW_NUMBER":"754613","VIOLATION_NO":"7188018","ISSUE_DT":"10/18/2000","CFR_STANDARD_CD":"77.1605(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-10-18"},{"SOURCE_ROW_NUMBER":"752851","VIOLATION_NO":"7189523","ISSUE_DT":"06/13/2000","CFR_STANDARD_CD":"77.1710(e)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"66.00","CURRENT_ASSESSMENT_AMT":"66.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-06-13"},{"SOURCE_ROW_NUMBER":"752850","VIOLATION_NO":"7189522","ISSUE_DT":"06/13/2000","CFR_STANDARD_CD":"77.208(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-06-13"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":43,"firstDate":"2000-06-12","lastDate":"2007-01-25","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":0,"validSamples":43,"maxConcentration":0.279,"concentrationTotal":4.427},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1354864","CASS_NUM":"57650770","SMP_TAKEN_DT":"1/25/2007","CONC":".023","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"TRANSIT MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-01-25"},{"SOURCE_ROW_NUMBER":"1350876","CASS_NUM":"57650829","SMP_TAKEN_DT":"1/25/2007","CONC":".001","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-01-25"},{"SOURCE_ROW_NUMBER":"813617","CASS_NUM":"57650775","SMP_TAKEN_DT":"1/25/2007","CONC":".083","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-01-25"},{"SOURCE_ROW_NUMBER":"351306","CASS_NUM":"57650811","SMP_TAKEN_DT":"1/25/2007","CONC":".047","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-01-25"},{"SOURCE_ROW_NUMBER":"349048","CASS_NUM":"57650798","SMP_TAKEN_DT":"1/25/2007","CONC":".181","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"GROUNDMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-01-25"},{"SOURCE_ROW_NUMBER":"1362228","CASS_NUM":"57551307","SMP_TAKEN_DT":"11/2/2005","CONC":".047","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-11-02"},{"SOURCE_ROW_NUMBER":"1019959","CASS_NUM":"57551632","SMP_TAKEN_DT":"11/2/2005","CONC":".161","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-11-02"},{"SOURCE_ROW_NUMBER":"761348","CASS_NUM":"57551664","SMP_TAKEN_DT":"11/2/2005","CONC":".048","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-11-02"},{"SOURCE_ROW_NUMBER":"722267","CASS_NUM":"57551269","SMP_TAKEN_DT":"11/2/2005","CONC":".081","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-11-02"},{"SOURCE_ROW_NUMBER":"435144","CASS_NUM":"57551281","SMP_TAKEN_DT":"11/2/2005","CONC":".02","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-11-02"},{"SOURCE_ROW_NUMBER":"1631740","CASS_NUM":"57541283","SMP_TAKEN_DT":"6/9/2005","CONC":".056","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-06-09"},{"SOURCE_ROW_NUMBER":"1556678","CASS_NUM":"57541291","SMP_TAKEN_DT":"6/9/2005","CONC":".201","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-06-09"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":134,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":26,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2000-04-01","lastDate":"2000-04-01","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":33,"firstDate":"2000-04-24","lastDate":"2011-03-07","metrics":{"inspectors":39,"recentRows":0,"onSiteHours":336.25,"inspectionHours":705,"inspectionSamples":13},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"76892","EVENT_NO":"6288430","INSPECTION_BEGIN_DT":"03/07/2011","INSPECTION_END_DT":"03/22/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.25","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2011-03-07"},{"SOURCE_ROW_NUMBER":"906256","EVENT_NO":"6286924","INSPECTION_BEGIN_DT":"05/04/2010","INSPECTION_END_DT":"05/12/2010","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2010-05-04"},{"SOURCE_ROW_NUMBER":"251826","EVENT_NO":"6286915","INSPECTION_BEGIN_DT":"12/07/2009","INSPECTION_END_DT":"12/08/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2009-12-07"},{"SOURCE_ROW_NUMBER":"93559","EVENT_NO":"4118566","INSPECTION_BEGIN_DT":"07/06/2009","INSPECTION_END_DT":"07/14/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2009-07-06"},{"SOURCE_ROW_NUMBER":"351959","EVENT_NO":"4119017","INSPECTION_BEGIN_DT":"02/21/2009","INSPECTION_END_DT":"02/21/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2009-02-21"},{"SOURCE_ROW_NUMBER":"971350","EVENT_NO":"4119005","INSPECTION_BEGIN_DT":"06/12/2008","INSPECTION_END_DT":"06/13/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2008-06-12"},{"SOURCE_ROW_NUMBER":"470667","EVENT_NO":"4113445","INSPECTION_BEGIN_DT":"03/10/2008","INSPECTION_END_DT":"03/11/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.75","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2008-03-10"},{"SOURCE_ROW_NUMBER":"255023","EVENT_NO":"4115982","INSPECTION_BEGIN_DT":"09/04/2007","INSPECTION_END_DT":"09/11/2007","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"10.5","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2007-09-04"},{"SOURCE_ROW_NUMBER":"1101262","EVENT_NO":"4109937","INSPECTION_BEGIN_DT":"01/08/2007","INSPECTION_END_DT":"02/20/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"52","SUM_TOTAL_ON_SITE_HOURS":"21.5","sourceDate":"2007-01-08"},{"SOURCE_ROW_NUMBER":"56602","EVENT_NO":"4110572","INSPECTION_BEGIN_DT":"02/02/2006","INSPECTION_END_DT":"04/10/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"29.5","SUM_TOTAL_ON_SITE_HOURS":"17.5","sourceDate":"2006-02-02"},{"SOURCE_ROW_NUMBER":"768328","EVENT_NO":"4097694","INSPECTION_BEGIN_DT":"10/03/2005","INSPECTION_END_DT":"11/03/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"34","SUM_TOTAL_ON_SITE_HOURS":"20.5","sourceDate":"2005-10-03"},{"SOURCE_ROW_NUMBER":"276434","EVENT_NO":"4110562","INSPECTION_BEGIN_DT":"08/15/2005","INSPECTION_END_DT":"08/17/2005","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"17.5","SUM_TOTAL_ON_SITE_HOURS":"12.5","sourceDate":"2005-08-15"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":71,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2011-Q2":{"hours":0,"employees":0,"production":0},"2011-Q1":{"hours":0,"employees":0,"production":0},"2010-Q4":{"hours":0,"employees":0,"production":0},"2010-Q3":{"hours":0,"employees":0,"production":0},"2010-Q2":{"hours":0,"employees":0,"production":0},"2010-Q1":{"hours":0,"employees":0,"production":0},"2009-Q4":{"hours":0,"employees":0,"production":0},"2009-Q3":{"hours":0,"employees":0,"production":0},"2009-Q2":{"hours":0,"employees":0,"production":0},"2009-Q1":{"hours":0,"employees":0,"production":0},"2008-Q4":{"hours":0,"employees":0,"production":0},"2008-Q3":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":8,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":37180,"employees":24,"production":0},"2001":{"hours":43092,"employees":26,"production":0},"2002":{"hours":59649,"employees":25,"production":0},"2003":{"hours":77494,"employees":20,"production":0},"2004":{"hours":70026,"employees":33,"production":0},"2005":{"hours":72877,"employees":35,"production":0},"2006":{"hours":36816,"employees":30,"production":0},"2007":{"hours":37625,"employees":16,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":26,"firstDate":"2000-06-13","lastDate":"2007-02-05","metrics":{"recentRows":0,"doseOver100":4,"actDoseTotal":1681,"pelDoseTotal":915},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"245814","EVENT_NO":"4109937","SURVEY_DATE":"02/05/2007","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"79","PEL_DOSE_90":"40","SURVEY_TYPE":"I","sourceDate":"2007-02-05"},{"SOURCE_ROW_NUMBER":"245813","EVENT_NO":"4109937","SURVEY_DATE":"02/05/2007","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"73","PEL_DOSE_90":"64","SURVEY_TYPE":"I","sourceDate":"2007-02-05"},{"SOURCE_ROW_NUMBER":"245812","EVENT_NO":"4109937","SURVEY_DATE":"02/05/2007","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"40","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2007-02-05"},{"SOURCE_ROW_NUMBER":"245819","EVENT_NO":"4110562","SURVEY_DATE":"08/16/2005","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"63","PEL_DOSE_90":"43","SURVEY_TYPE":"I","sourceDate":"2005-08-16"},{"SOURCE_ROW_NUMBER":"245818","EVENT_NO":"4110562","SURVEY_DATE":"08/16/2005","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"29","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2005-08-16"},{"SOURCE_ROW_NUMBER":"245817","EVENT_NO":"4110562","SURVEY_DATE":"08/16/2005","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"44","PEL_DOSE_90":"24","SURVEY_TYPE":"I","sourceDate":"2005-08-16"},{"SOURCE_ROW_NUMBER":"245816","EVENT_NO":"4110562","SURVEY_DATE":"08/16/2005","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"48","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2005-08-16"},{"SOURCE_ROW_NUMBER":"245815","EVENT_NO":"4110562","SURVEY_DATE":"08/16/2005","OCCUPATION_CD_DESC":"TIPPLE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"61","PEL_DOSE_90":"43","SURVEY_TYPE":"I","sourceDate":"2005-08-16"},{"SOURCE_ROW_NUMBER":"245811","EVENT_NO":"4101375","SURVEY_DATE":"11/17/2003","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"84","PEL_DOSE_90":"38","SURVEY_TYPE":"I","sourceDate":"2003-11-17"},{"SOURCE_ROW_NUMBER":"245810","EVENT_NO":"4101375","SURVEY_DATE":"11/17/2003","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"81","PEL_DOSE_90":"56","SURVEY_TYPE":"I","sourceDate":"2003-11-17"},{"SOURCE_ROW_NUMBER":"245809","EVENT_NO":"4101375","SURVEY_DATE":"11/17/2003","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"47","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2003-11-17"},{"SOURCE_ROW_NUMBER":"245808","EVENT_NO":"4101375","SURVEY_DATE":"11/17/2003","OCCUPATION_CD_DESC":"WATCHMAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"72","PEL_DOSE_90":"39","SURVEY_TYPE":"I","sourceDate":"2003-11-17"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":14,"firstDate":"2000-06-13","lastDate":"2007-09-05","metrics":{"ss":6,"amountDue":992,"contested":0,"amountPaid":992,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":992},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2803444","VIOLATION_NO":"7275809","VIOLATION_ISSUE_DT":"09/05/2007","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/10/2007","PROPOSED_PENALTY":"162","AMOUNT_DUE":"162","AMOUNT_PAID":"162","CONTESTED_IND":"N","sourceDate":"2007-09-05"},{"SOURCE_ROW_NUMBER":"2803438","VIOLATION_NO":"7258586","VIOLATION_ISSUE_DT":"01/16/2007","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/22/2007","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2007-01-16"},{"SOURCE_ROW_NUMBER":"2803447","VIOLATION_NO":"7219614","VIOLATION_ISSUE_DT":"10/28/2003","SIG_SUB":"Y","PART_SECTION":"77.204","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/28/2003","PROPOSED_PENALTY":"91","AMOUNT_DUE":"91","AMOUNT_PAID":"91","CONTESTED_IND":"N","sourceDate":"2003-10-28"},{"SOURCE_ROW_NUMBER":"2803446","VIOLATION_NO":"7219613","VIOLATION_ISSUE_DT":"10/28/2003","SIG_SUB":"N","PART_SECTION":"77.205(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/28/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2003-10-28"},{"SOURCE_ROW_NUMBER":"2803445","VIOLATION_NO":"7219612","VIOLATION_ISSUE_DT":"10/20/2003","SIG_SUB":"N","PART_SECTION":"77.400(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/20/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2003-10-20"},{"SOURCE_ROW_NUMBER":"2803443","VIOLATION_NO":"7188095","VIOLATION_ISSUE_DT":"06/21/2001","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/25/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-06-21"},{"SOURCE_ROW_NUMBER":"2803450","VIOLATION_NO":"7188025","VIOLATION_ISSUE_DT":"11/02/2000","SIG_SUB":"Y","PART_SECTION":"77.400(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/08/2000","PROPOSED_PENALTY":"76","AMOUNT_DUE":"76","AMOUNT_PAID":"76","CONTESTED_IND":"N","sourceDate":"2000-11-02"},{"SOURCE_ROW_NUMBER":"2803449","VIOLATION_NO":"7188024","VIOLATION_ISSUE_DT":"11/02/2000","SIG_SUB":"Y","PART_SECTION":"77.400(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/08/2000","PROPOSED_PENALTY":"76","AMOUNT_DUE":"76","AMOUNT_PAID":"76","CONTESTED_IND":"N","sourceDate":"2000-11-02"},{"SOURCE_ROW_NUMBER":"2803451","VIOLATION_NO":"7188019","VIOLATION_ISSUE_DT":"10/23/2000","SIG_SUB":"N","PART_SECTION":"62.120","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/08/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-10-23"},{"SOURCE_ROW_NUMBER":"2803448","VIOLATION_NO":"7188018","VIOLATION_ISSUE_DT":"10/18/2000","SIG_SUB":"N","PART_SECTION":"77.1605(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/28/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-10-18"},{"SOURCE_ROW_NUMBER":"2803442","VIOLATION_NO":"7189523","VIOLATION_ISSUE_DT":"06/13/2000","SIG_SUB":"Y","PART_SECTION":"77.1710(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/13/2000","PROPOSED_PENALTY":"66","AMOUNT_DUE":"66","AMOUNT_PAID":"66","CONTESTED_IND":"N","sourceDate":"2000-06-13"},{"SOURCE_ROW_NUMBER":"2803441","VIOLATION_NO":"7189522","VIOLATION_ISSUE_DT":"06/13/2000","SIG_SUB":"N","PART_SECTION":"77.208(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/13/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-06-13"}]}],"safety":{"href":"/api/v1/mines/4608831/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4608831/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":1},{"chapter":"I","heading":"Openings in surface installations; safeguards.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.204","part":"77","subchapter":"O","subpart":"C","id":"77.204","citation":"30 CFR 77.204","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.205","heading":"Travelways at surface installations.","id":"77.205","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.205","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Safe means of access shall be provided and maintained to all working places.\n\n(b) Travelways and platforms or other means of access to areas where persons are required to travel or work, shall be kept clear of all extraneous material and other stumbling or slipping hazards.\n\n(c) Inclined travelways shall be constructed of nonskid material or equipped with cleats.\n\n(d) Regularly used travelways shall be sanded, salted, or cleared of snow and ice as soon as practicable.\n\n(e) Crossovers, elevated walkways, elevated ramps, and stairways shall be of substantial construction, provided with handrails, and maintained in good condition. Where necessary toeboards shall be provided.\n\n(f) Crossovers shall be provided where it is necessary to cross conveyors.\n\n(g) Moving conveyors shall be crossed only at designated crossover points.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.400","heading":"Mechanical equipment guards.","id":"77.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.400","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings; shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Overhead belts shall be guarded if the whipping action from a broken line would be hazardous to persons below.\n\n(c) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(d) Except when testing the machinery, guards shall be securely in place while machinery is being operated.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":1},{"chapter":"I","heading":"Action level.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-M/part-62/section-62.120","part":"62","subchapter":"M","subpart":"","id":"62.120","citation":"30 CFR 62.120","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER M—UNIFORM MINE HEALTH REGULATIONS","partHeading":"PART 62—OCCUPATIONAL NOISE EXPOSURE","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","heading":"Protective clothing; requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-R/section-77.1710","part":"77","subchapter":"O","subpart":"R","id":"77.1710","citation":"30 CFR 77.1710","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.208","heading":"Storage of materials.","id":"77.208","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.208","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Materials shall be stored and stacked in a manner which minimizes stumbling or fall-of-material hazards.\n\n(b) Materials that can create hazards if accidentally liberated from their containers shall be stored in a manner that minimizes the dangers.\n\n(c) Containers holding hazardous materials must be of a type approved for such use by recognized agencies.\n\n(d) Compressed and liquid gas cylinders shall be secured in a safe manner.\n\n(e) Valves on compressed gas cylinders shall be protected by covers when being transported or stored, and by a safe location when the cylinders are in use.\n\n[36 FR 9364, May 22, 1971, as amended at 67 FR 42389, June 21, 2002]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4608831","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}