{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4608829","name":"Beckley Mine","status":"Abandoned and Sealed","status_date":"2026-04-07","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Raleigh","nearest_town":"Slab Fork","operator_id":"0124070","operator_name":"Maben Coal LLC","controller_id":"0137341","controller_name":"Ramaco Resources Inc","district":"C04","office":"Beckley Field Office","employees":0,"latitude":37.666389,"longitude":-81.370833},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":10377},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4608829","name":"Beckley Mine"},"operator":{"type":"operator","id":"0124070","name":"Maben Coal LLC"},"controller":{"type":"controller","id":"0137341","name":"Ramaco Resources Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C14826","name":"Robert L  Worley"},"object":{"type":"mine","id":"4608829","name":"Beckley Mine"},"validFrom":"1993-01-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|C14826|1993-01-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24378","name":"Guyandotte-Pocahontas Energy Inc"},"object":{"type":"mine","id":"4608829","name":"Beckley Mine"},"validFrom":"2000-03-01","validTo":"2000-10-01","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|P24378|2000-03-01|2000-10-01"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15745","name":"R R D Inc"},"object":{"type":"mine","id":"4608829","name":"Beckley Mine"},"validFrom":"2000-03-01","validTo":"2000-10-01","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|C15745|2000-03-01|2000-10-01"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15745","name":"R R D Inc"},"object":{"type":"operator","id":"P24378","name":"Guyandotte-Pocahontas Energy Inc"},"validFrom":"2000-03-01","validTo":"2000-10-01","current":false,"derived":true,"evidenceMineId":"4608829","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|P24378|2000-03-01|C15745|2000-03-01|96671"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22311","name":"Baylor Mining Inc"},"object":{"type":"mine","id":"4608829","name":"Beckley Mine"},"validFrom":"2000-10-02","validTo":"2014-12-07","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|P22311|2000-10-02|2014-12-07"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14826","name":"Robert L  Worley"},"object":{"type":"operator","id":"P22311","name":"Baylor Mining Inc"},"validFrom":"2000-10-02","validTo":"2014-12-07","current":false,"derived":true,"evidenceMineId":"4608829","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|P22311|2000-10-02|C14826|1993-01-01|93980"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"4608829","name":"Beckley Mine"},"validFrom":"2007-06-30","validTo":"2016-07-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|0041211|2007-06-30|2016-07-25"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0105293","name":"Appleton Coal, LLC"},"object":{"type":"mine","id":"4608829","name":"Beckley Mine"},"validFrom":"2012-06-28","validTo":"2022-10-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|0105293|2012-06-28|2022-10-31"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0081364","name":"Brooks Run South Mining, LLC"},"object":{"type":"mine","id":"4608829","name":"Beckley Mine"},"validFrom":"2014-12-08","validTo":"2022-01-04","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|0081364|2014-12-08|2022-01-04"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"0081364","name":"Brooks Run South Mining, LLC"},"validFrom":"2014-12-08","validTo":"2016-07-25","current":false,"derived":true,"evidenceMineId":"4608829","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|0081364|2014-12-08|0041211|2007-06-30|1754"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"mine","id":"4608829","name":"Beckley Mine"},"validFrom":"2016-07-26","validTo":"2018-11-08","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|0127923|2016-07-26|2018-11-08"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"operator","id":"0081364","name":"Brooks Run South Mining, LLC"},"validFrom":"2016-07-26","validTo":"2018-11-08","current":false,"derived":true,"evidenceMineId":"4608829","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|0081364|2014-12-08|0127923|2016-07-26|25242"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"mine","id":"4608829","name":"Beckley Mine"},"validFrom":"2018-11-09","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|0127321|2018-11-09|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"operator","id":"0081364","name":"Brooks Run South Mining, LLC"},"validFrom":"2018-11-09","validTo":"2022-01-04","current":false,"derived":true,"evidenceMineId":"4608829","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|0081364|2014-12-08|0127321|2018-11-09|24877"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0180534","name":"Sundial Mining LLC"},"object":{"type":"mine","id":"4608829","name":"Beckley Mine"},"validFrom":"2022-01-05","validTo":"2025-10-16","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|0180534|2022-01-05|2025-10-16"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0159801","name":"Petri E Koivula et al"},"object":{"type":"mine","id":"4608829","name":"Beckley Mine"},"validFrom":"2022-01-05","validTo":"2022-06-05","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|0159801|2022-01-05|2022-06-05"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0159801","name":"Petri E Koivula et al"},"object":{"type":"operator","id":"0180534","name":"Sundial Mining LLC"},"validFrom":"2022-01-05","validTo":"2022-06-05","current":false,"derived":true,"evidenceMineId":"4608829","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|0180534|2022-01-05|0159801|2022-01-05|33361"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0159801","name":"John  McNab et al"},"object":{"type":"operator","id":"0180534","name":"Sundial Mining LLC"},"validFrom":"2022-01-05","validTo":"2022-06-05","current":false,"derived":true,"evidenceMineId":"4608829","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|0180534|2022-01-05|0159801|2022-01-05|33362"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0159801","name":"Mike  Jamison et al"},"object":{"type":"operator","id":"0180534","name":"Sundial Mining LLC"},"validFrom":"2022-01-05","validTo":"2022-06-05","current":false,"derived":true,"evidenceMineId":"4608829","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|0180534|2022-01-05|0159801|2022-01-05|33363"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0170221","name":"David Michael  Jamison et al"},"object":{"type":"mine","id":"4608829","name":"Beckley Mine"},"validFrom":"2022-06-06","validTo":"2026-08-11","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|0170221|2022-06-06|2026-08-11"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0170221","name":"David Michael  Jamison et al"},"object":{"type":"operator","id":"0180534","name":"Sundial Mining LLC"},"validFrom":"2022-06-06","validTo":"2025-10-16","current":false,"derived":true,"evidenceMineId":"4608829","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|0180534|2022-01-05|0170221|2022-06-06|35991"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0170221","name":"Petri E Koivula et al"},"object":{"type":"operator","id":"0180534","name":"Sundial Mining LLC"},"validFrom":"2022-06-06","validTo":"2025-10-16","current":false,"derived":true,"evidenceMineId":"4608829","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|0180534|2022-01-05|0170221|2022-06-06|35992"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0137341","name":"Ramaco Resources Inc"},"object":{"type":"mine","id":"4608829","name":"Beckley Mine"},"validFrom":"2022-11-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|0137341|2022-11-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0124070","name":"Maben Coal LLC"},"object":{"type":"mine","id":"4608829","name":"Beckley Mine"},"validFrom":"2025-10-17","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|0124070|2025-10-17|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0105293","name":"Appleton Coal, LLC"},"object":{"type":"operator","id":"0124070","name":"Maben Coal LLC"},"validFrom":"2025-10-17","validTo":"2022-10-31","current":false,"derived":true,"evidenceMineId":"4608829","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|0124070|2025-10-17|0105293|2012-06-28|18433"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0137341","name":"Ramaco Resources Inc"},"object":{"type":"operator","id":"0124070","name":"Maben Coal LLC"},"validFrom":"2025-10-17","validTo":null,"current":true,"derived":true,"evidenceMineId":"4608829","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|0124070|2025-10-17|0137341|2022-11-01|27767"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0196420","name":"Eagle Summit Resources LLC"},"object":{"type":"mine","id":"4608829","name":"Beckley Mine"},"validFrom":"2026-08-12","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|0196420|2026-08-12|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0196420","name":"Eagle Summit Resources LLC"},"object":{"type":"operator","id":"0180534","name":"Sundial Mining LLC"},"validFrom":"2026-08-12","validTo":"2025-10-16","current":false,"derived":true,"evidenceMineId":"4608829","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608829|0180534|2022-01-05|0196420|2026-08-12|41921"}}],"coverage":{"historyRecords":13,"edgeCount":28,"intervalAnomalies":2,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":220,"firstDate":"2001-06-27","lastDate":"2015-09-14","metrics":{"daysLost":5885,"injuries":174,"fatalities":0,"recentRows":0,"restrictedDays":21,"contractorRecords":4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"206052","DOCUMENT_NO":"220160560002","ACCIDENT_DT":"09/14/2015","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Belt foreman, Maintenance foreman, Maintenance supervisor","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employer was notified by compensation administrator that the employee had a diagnosis of pneumoconiosis on 9-14-15.","sourceDate":"2015-09-14"},{"SOURCE_ROW_NUMBER":"150202","DOCUMENT_NO":"220152310003","ACCIDENT_DT":"07/21/2015","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Section foreman, Bullgang foreman, Labor foreman, Leadman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was diagnosed with pneumoconiosis on 7-21-15.","sourceDate":"2015-07-21"},{"SOURCE_ROW_NUMBER":"98340","DOCUMENT_NO":"220151680002","ACCIDENT_DT":"06/11/2015","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was installing a rubrail on the left miner. He was using left hand to push the hoses over so the rubrail would close. As the rubrail closed against the miner it pushed a piece of rock against employees left ring finger and the hoses causing a laceration and a fracture to the tip of the finger","sourceDate":"2015-06-11"},{"SOURCE_ROW_NUMBER":"236235","DOCUMENT_NO":"220151600002","ACCIDENT_DT":"06/04/2015","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"IGNITION OR EXPLOSION OF GAS OR DUST","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"An unplanned ignition of gas occurred in the 7 right face on 6/4/2015. Ignition occurred during loading of the third shuttle car when the head of the continuous miner came into contact with the bottom. The operator shut down the miner and the flame above the ripper head was still present. He reactivated the sprays and the flame disappeared. No injuries were reported.","sourceDate":"2015-06-04"},{"SOURCE_ROW_NUMBER":"72592","DOCUMENT_NO":"220152590007","ACCIDENT_DT":"05/24/2015","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Belt foreman, Maintenance foreman, Maintenance supervisor","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employer was notified on 9/16/15 by the compensation administrator that the employee was diagnosed with pneumoconiosis on 5/24/15.","sourceDate":"2015-05-24"},{"SOURCE_ROW_NUMBER":"219000","DOCUMENT_NO":"220151110006","ACCIDENT_DT":"04/07/2015","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"6","NARRATIVE":"EE was cleaning top of power center. He picked up a bag of rock dust & twisted to his right to drop it on the ground & felt a sharp pain in right side of lower back. He went to the foreman & stated \"I may have hurt my back.\" Foreman asked if he needed to go outside. He said \"No, I'll be OK.\" He completed his shift. He went to the hospital the following day due to pain.","sourceDate":"2015-04-07"},{"SOURCE_ROW_NUMBER":"253408","DOCUMENT_NO":"220150570002","ACCIDENT_DT":"02/10/2015","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","NARRATIVE":"Employer received a pneumoconiosis claim on 2/19/15 noting an initial diagnosis on 2/10/15.","sourceDate":"2015-02-10"},{"SOURCE_ROW_NUMBER":"137113","DOCUMENT_NO":"220143160026","ACCIDENT_DT":"11/05/2014","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"23","NARRATIVE":"Employee was pulling a rib in the number 5 to 6 crosscut (near spad 6756). Tripped/slipped while pulling rib and pulled rib on him.","sourceDate":"2014-11-05"},{"SOURCE_ROW_NUMBER":"72591","DOCUMENT_NO":"220143020001","ACCIDENT_DT":"10/26/2014","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A roof fall occurred in the crosscut one break inby spad 6929, on the K-10 Panel. The roof fall will not be cleaned up. All approaches have been cribbed/timbered and dangered off.","sourceDate":"2014-10-26"},{"SOURCE_ROW_NUMBER":"175976","DOCUMENT_NO":"220142610007","ACCIDENT_DT":"09/08/2014","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"EE was at section feeder running rock through feeder when he attempted to hit steel bar to activate e-stop. The steel bar slid out by and did not hit e-stop. EE hit e-stop cable which caused a rock to flip over and pinned his hand and cut it.","sourceDate":"2014-09-08"},{"SOURCE_ROW_NUMBER":"137112","DOCUMENT_NO":"220142520007","ACCIDENT_DT":"09/02/2014","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A roof fall occurred in the #9 entry at spad 6879. The roof fall will not be cleaned up. All approaches have been cribbed and dangered off.","sourceDate":"2014-09-02"},{"SOURCE_ROW_NUMBER":"81327","DOCUMENT_NO":"220141810002","ACCIDENT_DT":"06/23/2014","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall occurred in the #4 entry at spad 6869. The roof fall will not be cleaned up. All approaches have been cribbed, timbered, and dangered off.","sourceDate":"2014-06-23"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2026-04-07","lastDate":"2026-04-07","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":1871,"firstDate":"2000-10-23","lastDate":"2017-04-03","metrics":{"ss":705,"delinquent":1803,"recentRows":0,"paidPenalty":748343,"proposedPenalty":971182,"currentAssessment":748642},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1878974","VIOLATION_NO":"9062344","ISSUE_DT":"04/03/2017","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"135.00","CURRENT_ASSESSMENT_AMT":"135.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2017-04-03"},{"SOURCE_ROW_NUMBER":"1878973","VIOLATION_NO":"9062343","ISSUE_DT":"04/03/2017","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"135.00","CURRENT_ASSESSMENT_AMT":"135.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2017-04-03"},{"SOURCE_ROW_NUMBER":"1873312","VIOLATION_NO":"9020129","ISSUE_DT":"11/03/2015","CFR_STANDARD_CD":"77.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"117.00","CURRENT_ASSESSMENT_AMT":"117.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-11-03"},{"SOURCE_ROW_NUMBER":"1873311","VIOLATION_NO":"9020128","ISSUE_DT":"11/02/2015","CFR_STANDARD_CD":"75.1403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-11-02"},{"SOURCE_ROW_NUMBER":"1873310","VIOLATION_NO":"9020127","ISSUE_DT":"11/02/2015","CFR_STANDARD_CD":"75.1100-2(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-11-02"},{"SOURCE_ROW_NUMBER":"1873309","VIOLATION_NO":"9020126","ISSUE_DT":"10/28/2015","CFR_STANDARD_CD":"75.333(b)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-10-28"},{"SOURCE_ROW_NUMBER":"1873308","VIOLATION_NO":"9020125","ISSUE_DT":"10/28/2015","CFR_STANDARD_CD":"75.1403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-10-28"},{"SOURCE_ROW_NUMBER":"1873307","VIOLATION_NO":"9020124","ISSUE_DT":"10/28/2015","CFR_STANDARD_CD":"75.1403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-10-28"},{"SOURCE_ROW_NUMBER":"1873306","VIOLATION_NO":"9020123","ISSUE_DT":"10/28/2015","CFR_STANDARD_CD":"75.1403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-10-28"},{"SOURCE_ROW_NUMBER":"1873305","VIOLATION_NO":"9020122","ISSUE_DT":"10/28/2015","CFR_STANDARD_CD":"75.1403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-10-28"},{"SOURCE_ROW_NUMBER":"1873304","VIOLATION_NO":"9020121","ISSUE_DT":"10/27/2015","CFR_STANDARD_CD":"75.1714(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"117.00","CURRENT_ASSESSMENT_AMT":"117.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-10-27"},{"SOURCE_ROW_NUMBER":"1873303","VIOLATION_NO":"9018489","ISSUE_DT":"10/27/2015","CFR_STANDARD_CD":"75.1405","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-10-27"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":283,"firstDate":"2003-09-05","lastDate":"2015-05-18","metrics":{"appeals":0,"decisions":283,"recentRows":0,"decisionPenalty":334728,"originalPenalty":558681},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"214297","VIOLATION_NO":"7272279","DOCKET_NO":"WEVA 2008-749","DECISION_DT":"05/18/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"873.00","DECISION_PENALTY_AMT":"550.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2015-05-18"},{"SOURCE_ROW_NUMBER":"370509","VIOLATION_NO":"9018297","DOCKET_NO":"WEVA 2015-0417","DECISION_DT":"05/06/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2015-05-06"},{"SOURCE_ROW_NUMBER":"370143","VIOLATION_NO":"9018295","DOCKET_NO":"WEVA 2015-0489","DECISION_DT":"05/06/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"392.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2015-05-06"},{"SOURCE_ROW_NUMBER":"369936","VIOLATION_NO":"9017334","DOCKET_NO":"WEVA 2015-0417","DECISION_DT":"05/06/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"873.00","DECISION_PENALTY_AMT":"600.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2015-05-06"},{"SOURCE_ROW_NUMBER":"369935","VIOLATION_NO":"9016834","DOCKET_NO":"WEVA 2015-0417","DECISION_DT":"05/06/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"334.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2015-05-06"},{"SOURCE_ROW_NUMBER":"369742","VIOLATION_NO":"9018296","DOCKET_NO":"WEVA 2015-0417","DECISION_DT":"05/06/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"585.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2015-05-06"},{"SOURCE_ROW_NUMBER":"369177","VIOLATION_NO":"9018043","DOCKET_NO":"WEVA 2015-0417","DECISION_DT":"05/06/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"334.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2015-05-06"},{"SOURCE_ROW_NUMBER":"369176","VIOLATION_NO":"9016831","DOCKET_NO":"WEVA 2015-0417","DECISION_DT":"05/06/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1530.00","DECISION_PENALTY_AMT":"1530.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2015-05-06"},{"SOURCE_ROW_NUMBER":"367341","VIOLATION_NO":"9018496","DOCKET_NO":"WEVA 2015-0134","DECISION_DT":"05/06/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1657.00","DECISION_PENALTY_AMT":"750.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2015-05-06"},{"SOURCE_ROW_NUMBER":"367340","VIOLATION_NO":"9017347","DOCKET_NO":"WEVA 2015-0134","DECISION_DT":"05/06/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"362.00","DECISION_PENALTY_AMT":"362.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2015-05-06"},{"SOURCE_ROW_NUMBER":"366798","VIOLATION_NO":"9017352","DOCKET_NO":"WEVA 2015-0134","DECISION_DT":"05/06/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"807.00","DECISION_PENALTY_AMT":"807.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2015-05-06"},{"SOURCE_ROW_NUMBER":"364757","VIOLATION_NO":"7223609","DOCKET_NO":"WEVA 2014-2185","DECISION_DT":"05/06/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"807.00","DECISION_PENALTY_AMT":"807.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2015-05-06"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":2001,"firstDate":"2001-04-16","lastDate":"2015-11-03","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":243,"validSamples":1758,"maxConcentration":86.195,"concentrationTotal":1591.424},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1491894","CASS_NUM":"58217650","SMP_TAKEN_DT":"11/3/2015","CONC":".188","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-03"},{"SOURCE_ROW_NUMBER":"345143","CASS_NUM":"58217572","SMP_TAKEN_DT":"11/2/2015","CONC":".505","SMP_TYPE_CD_DESC":"NONDESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SUPPLY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-02"},{"SOURCE_ROW_NUMBER":"237112","CASS_NUM":"58217468","SMP_TAKEN_DT":"11/2/2015","CONC":".216","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-02"},{"SOURCE_ROW_NUMBER":"96321","CASS_NUM":"58217458","SMP_TAKEN_DT":"11/2/2015","CONC":".367","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-02"},{"SOURCE_ROW_NUMBER":"49756","CASS_NUM":"58217462","SMP_TAKEN_DT":"11/2/2015","CONC":".232","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LABORER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-02"},{"SOURCE_ROW_NUMBER":"1022524","CASS_NUM":"51408593","SMP_TAKEN_DT":"10/28/2015","CONC":".293","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-10-28"},{"SOURCE_ROW_NUMBER":"405823","CASS_NUM":"51408610","SMP_TAKEN_DT":"10/28/2015","CONC":".837","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-10-28"},{"SOURCE_ROW_NUMBER":"1645044","CASS_NUM":"51408525","SMP_TAKEN_DT":"10/27/2015","CONC":".688","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-10-27"},{"SOURCE_ROW_NUMBER":"693091","CASS_NUM":"51408523","SMP_TAKEN_DT":"10/27/2015","CONC":".218","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-10-27"},{"SOURCE_ROW_NUMBER":"1591316","CASS_NUM":"51408591","SMP_TAKEN_DT":"10/22/2015","CONC":".727","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-10-22"},{"SOURCE_ROW_NUMBER":"427004","CASS_NUM":"51408598","SMP_TAKEN_DT":"10/22/2015","CONC":".766","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-10-22"},{"SOURCE_ROW_NUMBER":"575030","CASS_NUM":"51408590","SMP_TAKEN_DT":"10/21/2015","CONC":".918","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-10-21"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":26,"firstDate":"2001-06-21","lastDate":"2015-08-05","metrics":{"linkedIssuances":26},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":280,"firstDate":"2007-04-25","lastDate":"2014-11-04","metrics":{"decisions":280,"ssChanged":55,"recentRows":0,"decisionPenalty":332513,"proposedPenalty":554767},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"430263","CITATION_NO":"9018297","CITATION_ISSUE_DT":"11/04/2014","DOCKET_NO":"WEVA 2015-0417","DECISION_DT":"05/06/2015","CFR_STANDARD_CODE":"75.1100-3","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2014-11-04"},{"SOURCE_ROW_NUMBER":"262228","CITATION_NO":"9018298","CITATION_ISSUE_DT":"11/04/2014","DOCKET_NO":"WEVA 2015-0489","DECISION_DT":"05/06/2015","CFR_STANDARD_CODE":"75.333(h)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"263.00","DECISION_PENALTY_AMT":"263.00","sourceDate":"2014-11-04"},{"SOURCE_ROW_NUMBER":"430705","CITATION_NO":"9018295","CITATION_ISSUE_DT":"11/03/2014","DOCKET_NO":"WEVA 2015-0489","DECISION_DT":"05/06/2015","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"392.00","sourceDate":"2014-11-03"},{"SOURCE_ROW_NUMBER":"152101","CITATION_NO":"9018296","CITATION_ISSUE_DT":"11/03/2014","DOCKET_NO":"WEVA 2015-0417","DECISION_DT":"05/06/2015","CFR_STANDARD_CODE":"75.1722(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"585.00","sourceDate":"2014-11-03"},{"SOURCE_ROW_NUMBER":"96169","CITATION_NO":"9018294","CITATION_ISSUE_DT":"11/03/2014","DOCKET_NO":"WEVA 2015-0417","DECISION_DT":"05/06/2015","CFR_STANDARD_CODE":"75.360(g)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2014-11-03"},{"SOURCE_ROW_NUMBER":"948","CITATION_NO":"9017366","CITATION_ISSUE_DT":"10/23/2014","DOCKET_NO":"WEVA 2015-0417","DECISION_DT":"05/06/2015","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2014-10-23"},{"SOURCE_ROW_NUMBER":"91261","CITATION_NO":"9015809","CITATION_ISSUE_DT":"09/24/2014","DOCKET_NO":"WEVA 2015-0474","DECISION_DT":"05/06/2015","CFR_STANDARD_CODE":"75.511","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"16400.00","DECISION_PENALTY_AMT":"6500.00","sourceDate":"2014-09-24"},{"SOURCE_ROW_NUMBER":"147295","CITATION_NO":"9017352","CITATION_ISSUE_DT":"09/04/2014","DOCKET_NO":"WEVA 2015-0134","DECISION_DT":"05/06/2015","CFR_STANDARD_CODE":"75.380(d)(7)(iv)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"807.00","DECISION_PENALTY_AMT":"807.00","sourceDate":"2014-09-04"},{"SOURCE_ROW_NUMBER":"430895","CITATION_NO":"9017348","CITATION_ISSUE_DT":"09/03/2014","DOCKET_NO":"WEVA 2015-0134","DECISION_DT":"05/06/2015","CFR_STANDARD_CODE":"75.1102","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"362.00","DECISION_PENALTY_AMT":"362.00","sourceDate":"2014-09-03"},{"SOURCE_ROW_NUMBER":"91149","CITATION_NO":"9017347","CITATION_ISSUE_DT":"09/03/2014","DOCKET_NO":"WEVA 2015-0134","DECISION_DT":"05/06/2015","CFR_STANDARD_CODE":"75.1731(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"362.00","DECISION_PENALTY_AMT":"362.00","sourceDate":"2014-09-03"},{"SOURCE_ROW_NUMBER":"375379","CITATION_NO":"9018496","CITATION_ISSUE_DT":"08/27/2014","DOCKET_NO":"WEVA 2015-0134","DECISION_DT":"05/06/2015","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1657.00","DECISION_PENALTY_AMT":"750.00","sourceDate":"2014-08-27"},{"SOURCE_ROW_NUMBER":"147365","CITATION_NO":"9017345","CITATION_ISSUE_DT":"07/21/2014","DOCKET_NO":"WEVA 2015-0045","DECISION_DT":"05/06/2015","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"946.00","DECISION_PENALTY_AMT":"650.00","sourceDate":"2014-07-21"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":1947,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":19,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":359,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":19,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":13,"firstDate":"2000-03-01","lastDate":"2025-10-17","metrics":{"recentRows":8,"currentOperatorTenures":2,"completedOperatorTenures":11},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":1029,"firstDate":"2000-04-03","lastDate":"2026-04-01","metrics":{"inspectors":1328,"recentRows":4,"onSiteHours":12634.25,"inspectionHours":19553.5,"inspectionSamples":1785},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"197855","EVENT_NO":"F01FF33","INSPECTION_BEGIN_DT":"04/01/2026","INSPECTION_END_DT":"04/01/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2026-04-01"},{"SOURCE_ROW_NUMBER":"704497","EVENT_NO":"F008563","INSPECTION_BEGIN_DT":"09/22/2025","INSPECTION_END_DT":"09/22/2025","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2025-09-22"},{"SOURCE_ROW_NUMBER":"570026","EVENT_NO":"F008556","INSPECTION_BEGIN_DT":"03/26/2025","INSPECTION_END_DT":"03/26/2025","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2025-03-26"},{"SOURCE_ROW_NUMBER":"291214","EVENT_NO":"F01D4BE","INSPECTION_BEGIN_DT":"03/25/2025","INSPECTION_END_DT":"03/25/2025","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2025-03-25"},{"SOURCE_ROW_NUMBER":"339034","EVENT_NO":"7008075","INSPECTION_BEGIN_DT":"10/01/2018","INSPECTION_END_DT":"10/01/2018","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.25","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2018-10-01"},{"SOURCE_ROW_NUMBER":"1125259","EVENT_NO":"7004550","INSPECTION_BEGIN_DT":"04/05/2018","INSPECTION_END_DT":"04/05/2018","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2018-04-05"},{"SOURCE_ROW_NUMBER":"1146548","EVENT_NO":"7007654","INSPECTION_BEGIN_DT":"01/23/2018","INSPECTION_END_DT":"01/23/2018","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2018-01-23"},{"SOURCE_ROW_NUMBER":"971157","EVENT_NO":"7003117","INSPECTION_BEGIN_DT":"10/02/2017","INSPECTION_END_DT":"10/02/2017","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2017-10-02"},{"SOURCE_ROW_NUMBER":"230012","EVENT_NO":"6307847","INSPECTION_BEGIN_DT":"07/13/2017","INSPECTION_END_DT":"07/13/2017","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2017-07-13"},{"SOURCE_ROW_NUMBER":"524324","EVENT_NO":"6307864","INSPECTION_BEGIN_DT":"04/03/2017","INSPECTION_END_DT":"04/06/2017","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12.75","SUM_TOTAL_ON_SITE_HOURS":"5.25","sourceDate":"2017-04-03"},{"SOURCE_ROW_NUMBER":"977586","EVENT_NO":"7003800","INSPECTION_BEGIN_DT":"02/01/2017","INSPECTION_END_DT":"02/01/2017","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2017-02-01"},{"SOURCE_ROW_NUMBER":"220378","EVENT_NO":"6307823","INSPECTION_BEGIN_DT":"01/10/2017","INSPECTION_END_DT":"01/10/2017","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2017-01-10"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":194,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2021-Q4":{"hours":0,"employees":0,"production":0},"2021-Q3":{"hours":0,"employees":0,"production":0},"2021-Q2":{"hours":0,"employees":0,"production":0},"2021-Q1":{"hours":0,"employees":0,"production":0},"2020-Q4":{"hours":0,"employees":0,"production":0},"2020-Q3":{"hours":0,"employees":0,"production":0},"2020-Q2":{"hours":0,"employees":0,"production":0},"2020-Q1":{"hours":0,"employees":0,"production":0},"2019-Q4":{"hours":0,"employees":0,"production":0},"2019-Q3":{"hours":0,"employees":0,"production":0},"2019-Q2":{"hours":0,"employees":0,"production":0},"2019-Q1":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":32,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2007":{"hours":137778,"employees":59,"production":318033},"2008":{"hours":123451,"employees":54,"production":333055},"2009":{"hours":90066,"employees":49,"production":286600},"2010":{"hours":114260,"employees":50,"production":241137},"2011":{"hours":99882,"employees":45,"production":140470},"2012":{"hours":95409,"employees":44,"production":167345},"2013":{"hours":111430,"employees":47,"production":194242},"2014":{"hours":92919,"employees":52,"production":240787},"2015":{"hours":125534,"employees":67,"production":161183},"2016":{"hours":743,"employees":2,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":130,"firstDate":"2003-03-18","lastDate":"2015-11-03","metrics":{"recentRows":0,"doseOver100":11,"actDoseTotal":7191,"pelDoseTotal":5115},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"245787","EVENT_NO":"6306068","SURVEY_DATE":"11/03/2015","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"17","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2015-11-03"},{"SOURCE_ROW_NUMBER":"245786","EVENT_NO":"6306068","SURVEY_DATE":"11/02/2015","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"25","MANUFACTURER_CD":"119","ACT_DOSE_85":"25","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2015-11-02"},{"SOURCE_ROW_NUMBER":"245785","EVENT_NO":"6306068","SURVEY_DATE":"11/02/2015","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"25","MANUFACTURER_CD":"119","ACT_DOSE_85":"39","PEL_DOSE_90":"18","SURVEY_TYPE":"I","sourceDate":"2015-11-02"},{"SOURCE_ROW_NUMBER":"245793","EVENT_NO":"6306068","SURVEY_DATE":"10/14/2015","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"50","PEL_DOSE_90":"31","SURVEY_TYPE":"I","sourceDate":"2015-10-14"},{"SOURCE_ROW_NUMBER":"245792","EVENT_NO":"6306068","SURVEY_DATE":"10/14/2015","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"28","PEL_DOSE_90":"14","SURVEY_TYPE":"I","sourceDate":"2015-10-14"},{"SOURCE_ROW_NUMBER":"245791","EVENT_NO":"6306068","SURVEY_DATE":"10/14/2015","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"30","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2015-10-14"},{"SOURCE_ROW_NUMBER":"245790","EVENT_NO":"6306068","SURVEY_DATE":"10/14/2015","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"64","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2015-10-14"},{"SOURCE_ROW_NUMBER":"245789","EVENT_NO":"6306068","SURVEY_DATE":"10/14/2015","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"21","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2015-10-14"},{"SOURCE_ROW_NUMBER":"245788","EVENT_NO":"6306068","SURVEY_DATE":"10/14/2015","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"40","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2015-10-14"},{"SOURCE_ROW_NUMBER":"245784","EVENT_NO":"6306068","SURVEY_DATE":"10/14/2015","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"65","PEL_DOSE_90":"58","SURVEY_TYPE":"I","sourceDate":"2015-10-14"},{"SOURCE_ROW_NUMBER":"245783","EVENT_NO":"6306068","SURVEY_DATE":"10/14/2015","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"64","PEL_DOSE_90":"55","SURVEY_TYPE":"I","sourceDate":"2015-10-14"},{"SOURCE_ROW_NUMBER":"245782","EVENT_NO":"6306068","SURVEY_DATE":"10/14/2015","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"22","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2015-10-14"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":86,"firstDate":"2002-01-08","lastDate":"2015-11-02","metrics":{"recentRows":0,"voidSamples":7,"maxQuartzPct":17.9,"validSamples":79,"quartzPctTotal":316.3},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"122785","CASSETTE_NO":"58217468","SAMPLE_DT":"11/02/2015","QUARTZ_PCT":"03.4","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-11-02"},{"SOURCE_ROW_NUMBER":"111794","CASSETTE_NO":"58217458","SAMPLE_DT":"11/02/2015","QUARTZ_PCT":"01.6","QUARTZ_MICROGRAMS":"5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-11-02"},{"SOURCE_ROW_NUMBER":"40055","CASSETTE_NO":"58217659","SAMPLE_DT":"10/14/2015","QUARTZ_PCT":"02.0","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-10-14"},{"SOURCE_ROW_NUMBER":"17719","CASSETTE_NO":"58217666","SAMPLE_DT":"10/14/2015","QUARTZ_PCT":"02.1","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-10-14"},{"SOURCE_ROW_NUMBER":"35213","CASSETTE_NO":"58182603","SAMPLE_DT":"08/28/2015","QUARTZ_PCT":"03.0","QUARTZ_MICROGRAMS":"9","OCC_CODE_DESC":"LABORER","SAMPLE_TYPE_DESC":"PART 90 MINER","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-08-28"},{"SOURCE_ROW_NUMBER":"118087","CASSETTE_NO":"58182535","SAMPLE_DT":"07/20/2015","QUARTZ_PCT":"03.2","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-07-20"},{"SOURCE_ROW_NUMBER":"8890","CASSETTE_NO":"58182643","SAMPLE_DT":"07/20/2015","QUARTZ_PCT":"02.0","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-07-20"},{"SOURCE_ROW_NUMBER":"168245","CASSETTE_NO":"58182858","SAMPLE_DT":"05/28/2015","QUARTZ_PCT":"02.7","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-05-28"},{"SOURCE_ROW_NUMBER":"94371","CASSETTE_NO":"58182571","SAMPLE_DT":"05/28/2015","QUARTZ_PCT":"02.8","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-05-28"},{"SOURCE_ROW_NUMBER":"7785","CASSETTE_NO":"58182652","SAMPLE_DT":"05/28/2015","QUARTZ_PCT":"01.8","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-05-28"},{"SOURCE_ROW_NUMBER":"140761","CASSETTE_NO":"58182704","SAMPLE_DT":"03/23/2015","QUARTZ_PCT":"03.1","QUARTZ_MICROGRAMS":"12","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-03-23"},{"SOURCE_ROW_NUMBER":"18994","CASSETTE_NO":"58182915","SAMPLE_DT":"03/23/2015","QUARTZ_PCT":"03.1","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-03-23"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":1904,"firstDate":"2000-10-23","lastDate":"2017-04-03","metrics":{"ss":703,"amountDue":748642,"contested":98,"amountPaid":748343,"recentRows":0,"section104d":15,"unterminated":4,"proposedPenalty":971182},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2802111","VIOLATION_NO":"9062344","VIOLATION_ISSUE_DT":"04/03/2017","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"04/06/2017","PROPOSED_PENALTY":"135","AMOUNT_DUE":"135","AMOUNT_PAID":"135","CONTESTED_IND":"N","sourceDate":"2017-04-03"},{"SOURCE_ROW_NUMBER":"2802110","VIOLATION_NO":"9062343","VIOLATION_ISSUE_DT":"04/03/2017","SIG_SUB":"N","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"04/06/2017","PROPOSED_PENALTY":"135","AMOUNT_DUE":"135","AMOUNT_PAID":"135","CONTESTED_IND":"N","sourceDate":"2017-04-03"},{"SOURCE_ROW_NUMBER":"2803034","VIOLATION_NO":"9020129","VIOLATION_ISSUE_DT":"11/03/2015","SIG_SUB":"N","PART_SECTION":"77.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/04/2015","PROPOSED_PENALTY":"117","AMOUNT_DUE":"117","AMOUNT_PAID":"117","CONTESTED_IND":"N","sourceDate":"2015-11-03"},{"SOURCE_ROW_NUMBER":"2803033","VIOLATION_NO":"9020128","VIOLATION_ISSUE_DT":"11/02/2015","SIG_SUB":"N","PART_SECTION":"75.1403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/02/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-11-02"},{"SOURCE_ROW_NUMBER":"2803032","VIOLATION_NO":"9020127","VIOLATION_ISSUE_DT":"11/02/2015","SIG_SUB":"N","PART_SECTION":"75.1100-2(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/02/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-11-02"},{"SOURCE_ROW_NUMBER":"2803031","VIOLATION_NO":"9020126","VIOLATION_ISSUE_DT":"10/28/2015","SIG_SUB":"N","PART_SECTION":"75.333(b)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/02/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-10-28"},{"SOURCE_ROW_NUMBER":"2803030","VIOLATION_NO":"9020125","VIOLATION_ISSUE_DT":"10/28/2015","SIG_SUB":"N","PART_SECTION":"75.1403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/02/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-10-28"},{"SOURCE_ROW_NUMBER":"2803029","VIOLATION_NO":"9020124","VIOLATION_ISSUE_DT":"10/28/2015","SIG_SUB":"N","PART_SECTION":"75.1403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/02/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-10-28"},{"SOURCE_ROW_NUMBER":"2803028","VIOLATION_NO":"9020123","VIOLATION_ISSUE_DT":"10/28/2015","SIG_SUB":"N","PART_SECTION":"75.1403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/02/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-10-28"},{"SOURCE_ROW_NUMBER":"2803027","VIOLATION_NO":"9020122","VIOLATION_ISSUE_DT":"10/28/2015","SIG_SUB":"N","PART_SECTION":"75.1403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/02/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-10-28"},{"SOURCE_ROW_NUMBER":"2803026","VIOLATION_NO":"9020121","VIOLATION_ISSUE_DT":"10/27/2015","SIG_SUB":"N","PART_SECTION":"75.1714(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/27/2015","PROPOSED_PENALTY":"117","AMOUNT_DUE":"117","AMOUNT_PAID":"117","CONTESTED_IND":"N","sourceDate":"2015-10-27"},{"SOURCE_ROW_NUMBER":"2803025","VIOLATION_NO":"9018489","VIOLATION_ISSUE_DT":"10/27/2015","SIG_SUB":"N","PART_SECTION":"75.1405","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/03/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-10-27"}]}],"safety":{"href":"/api/v1/mines/4608829/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4608829/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.512","heading":"Inspection and cover plates.","id":"77.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.512","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Inspection and cover plates on electrical equipment shall be kept in place at all times except during testing or repairs.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403","heading":"Other safeguards.","id":"75.1403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"[Statutory Provisions]\n\nOther safeguards adequate, in the judgment of an authorized representative of the Secretary, to minimize hazards with respect to transportation of men and materials shall be provided.","occurrenceCount":5},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","heading":"Availability of approved self-rescue devices; instruction in use and location.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714","part":"75","subchapter":"O","subpart":"R","id":"75.1714","citation":"30 CFR 75.1714","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Automatic couplers.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1405","part":"75","subchapter":"O","subpart":"O","id":"75.1405","citation":"30 CFR 75.1405","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4608829","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}