{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4608828","name":"No. 3","status":"Abandoned and Sealed","status_date":"2010-09-28","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Mingo","nearest_town":"Thacker","operator_id":"P21386","operator_name":"Continuous Mining Co., Inc.","controller_id":"C13045","controller_name":"Eddie  Hurley","district":"C04","office":"Beckley District","employees":0,"latitude":37.565555,"longitude":-82.080555},"coverage":{"contributingSources":12,"registeredSources":20,"sourceRows":289},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4608828","name":"No. 3"},"operator":{"type":"operator","id":"P21386","name":"Continuous Mining Co., Inc."},"controller":{"type":"controller","id":"C13045","name":"Eddie  Hurley"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13045","name":"Eddie  Hurley"},"object":{"type":"mine","id":"4608828","name":"No. 3"},"validFrom":"1991-02-25","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608828|C13045|1991-02-25|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P21386","name":"Continuous Mining Company Inc"},"object":{"type":"mine","id":"4608828","name":"No. 3"},"validFrom":"2000-03-01","validTo":"2003-04-27","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608828|P21386|2000-03-01|2003-04-27"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13045","name":"Eddie  Hurley"},"object":{"type":"operator","id":"P21386","name":"Continuous Mining Company Inc"},"validFrom":"2000-03-01","validTo":"2003-04-27","current":false,"derived":true,"evidenceMineId":"4608828","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608828|P21386|2000-03-01|C13045|1991-02-25|88497"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C14990","name":"Danny  Justus"},"object":{"type":"mine","id":"4608828","name":"No. 3"},"validFrom":"2001-11-07","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608828|C14990|2001-11-07|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0050060","name":"Top Gun Mining, Inc."},"object":{"type":"mine","id":"4608828","name":"No. 3"},"validFrom":"2003-04-28","validTo":"2003-08-20","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608828|0050060|2003-04-28|2003-08-20"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14990","name":"Danny  Justus"},"object":{"type":"operator","id":"0050060","name":"Top Gun Mining, Inc."},"validFrom":"2003-04-28","validTo":"2003-08-20","current":false,"derived":true,"evidenceMineId":"4608828","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608828|0050060|2003-04-28|C14990|2001-11-07|94408"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P21386","name":"Continuous Mining Co., Inc."},"object":{"type":"mine","id":"4608828","name":"No. 3"},"validFrom":"2003-08-21","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608828|P21386|2003-08-21|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13045","name":"Eddie  Hurley"},"object":{"type":"operator","id":"P21386","name":"Continuous Mining Co., Inc."},"validFrom":"2003-08-21","validTo":null,"current":true,"derived":true,"evidenceMineId":"4608828","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608828|P21386|2003-08-21|C13045|1991-02-25|88498"}}],"coverage":{"historyRecords":3,"edgeCount":8,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":3,"firstDate":"2002-01-10","lastDate":"2003-02-06","metrics":{"daysLost":721,"injuries":3,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":3},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"249107","DOCUMENT_NO":"220030550014","ACCIDENT_DT":"02/06/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"NO VALUE FOUND","ACCIDENT_TYPE":"No Value Found","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"353","NARRATIVE":"EE REPORTED THAT HE EXPERIENCED PAIN IN HIS LOWER RIGHT BACK WHILE LIFTING A CONVEYOR BOOM JACK, FROM THE MINE FLOOR TO THE MANCAR APPORX.18\" LIFT","sourceDate":"2003-02-06"},{"SOURCE_ROW_NUMBER":"240539","DOCUMENT_NO":"220022100152","ACCIDENT_DT":"07/10/2002","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","NARRATIVE":"WHILE CHANGING OIL FILTER THE FILTER FELL & CUT THROUGH FINGERNAIL ON RIGHT RING FINGER.","sourceDate":"2002-07-10"},{"SOURCE_ROW_NUMBER":"150199","DOCUMENT_NO":"220020420016","ACCIDENT_DT":"01/10/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"368","NARRATIVE":"CUT TREE AND FELL ON EMPLOYEE.","sourceDate":"2002-01-10"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2010-09-28","lastDate":"2010-09-28","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":16,"firstDate":"2002-06-25","lastDate":"2003-07-23","metrics":{"ss":4,"delinquent":16,"recentRows":0,"paidPenalty":968,"proposedPenalty":968,"currentAssessment":968},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"782489","VIOLATION_NO":"4892698","ISSUE_DT":"07/23/2003","CFR_STANDARD_CD":"75.333(d)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-07-23"},{"SOURCE_ROW_NUMBER":"782477","VIOLATION_NO":"4892696","ISSUE_DT":"06/05/2003","CFR_STANDARD_CD":"75.1103-5(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"75.00","CURRENT_ASSESSMENT_AMT":"75.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-06-05"},{"SOURCE_ROW_NUMBER":"782476","VIOLATION_NO":"4892695","ISSUE_DT":"06/05/2003","CFR_STANDARD_CD":"75.1202","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-06-05"},{"SOURCE_ROW_NUMBER":"782475","VIOLATION_NO":"4892693","ISSUE_DT":"05/23/2003","CFR_STANDARD_CD":"72.630(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-05-23"},{"SOURCE_ROW_NUMBER":"782474","VIOLATION_NO":"4892692","ISSUE_DT":"05/21/2003","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-05-21"},{"SOURCE_ROW_NUMBER":"782473","VIOLATION_NO":"4892691","ISSUE_DT":"05/21/2003","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-05-21"},{"SOURCE_ROW_NUMBER":"782457","VIOLATION_NO":"4189076","ISSUE_DT":"01/02/2003","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-01-02"},{"SOURCE_ROW_NUMBER":"781487","VIOLATION_NO":"4893323","ISSUE_DT":"11/12/2002","CFR_STANDARD_CD":"77.701","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-11-12"},{"SOURCE_ROW_NUMBER":"781486","VIOLATION_NO":"4893322","ISSUE_DT":"11/06/2002","CFR_STANDARD_CD":"75.523-1(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"66.00","CURRENT_ASSESSMENT_AMT":"66.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-11-06"},{"SOURCE_ROW_NUMBER":"781485","VIOLATION_NO":"4893321","ISSUE_DT":"10/01/2002","CFR_STANDARD_CD":"75.1715","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-10-01"},{"SOURCE_ROW_NUMBER":"781484","VIOLATION_NO":"7218382","ISSUE_DT":"09/19/2002","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"76.00","CURRENT_ASSESSMENT_AMT":"76.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-09-19"},{"SOURCE_ROW_NUMBER":"781483","VIOLATION_NO":"7218381","ISSUE_DT":"09/18/2002","CFR_STANDARD_CD":"77.208(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-09-18"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":61,"firstDate":"2002-09-19","lastDate":"2003-07-11","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":0,"validSamples":61,"maxConcentration":9.112,"concentrationTotal":46.537},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1267197","CASS_NUM":"50677469","SMP_TAKEN_DT":"7/11/2003","CONC":".523","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-07-11"},{"SOURCE_ROW_NUMBER":"1074373","CASS_NUM":"50677466","SMP_TAKEN_DT":"7/10/2003","CONC":".409","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-07-10"},{"SOURCE_ROW_NUMBER":"173710","CASS_NUM":"50677461","SMP_TAKEN_DT":"7/9/2003","CONC":".284","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-07-09"},{"SOURCE_ROW_NUMBER":"1272522","CASS_NUM":"50677458","SMP_TAKEN_DT":"7/8/2003","CONC":".412","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-07-08"},{"SOURCE_ROW_NUMBER":"131884","CASS_NUM":"50677487","SMP_TAKEN_DT":"7/7/2003","CONC":".549","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-07-07"},{"SOURCE_ROW_NUMBER":"514774","CASS_NUM":"50677065","SMP_TAKEN_DT":"6/6/2003","CONC":".362","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-06-06"},{"SOURCE_ROW_NUMBER":"664349","CASS_NUM":"50677025","SMP_TAKEN_DT":"6/5/2003","CONC":".549","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-06-05"},{"SOURCE_ROW_NUMBER":"1559853","CASS_NUM":"50677530","SMP_TAKEN_DT":"6/4/2003","CONC":"1.219","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-06-04"},{"SOURCE_ROW_NUMBER":"557508","CASS_NUM":"50677520","SMP_TAKEN_DT":"6/3/2003","CONC":".444","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-06-03"},{"SOURCE_ROW_NUMBER":"1577012","CASS_NUM":"50677575","SMP_TAKEN_DT":"6/2/2003","CONC":".58","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-06-02"},{"SOURCE_ROW_NUMBER":"774164","CASS_NUM":"50677552","SMP_TAKEN_DT":"6/2/2003","CONC":".376","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-06-02"},{"SOURCE_ROW_NUMBER":"1637746","CASS_NUM":"57395258","SMP_TAKEN_DT":"5/21/2003","CONC":".25","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-05-21"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":117,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":29,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"2000-03-01","lastDate":"2003-08-21","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":30,"firstDate":"2002-02-06","lastDate":"2004-04-06","metrics":{"inspectors":35,"recentRows":0,"onSiteHours":310.25,"inspectionHours":695,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"75603","EVENT_NO":"6181461","INSPECTION_BEGIN_DT":"04/06/2004","INSPECTION_END_DT":"04/06/2004","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2004-04-06"},{"SOURCE_ROW_NUMBER":"1118168","EVENT_NO":"4101033","INSPECTION_BEGIN_DT":"10/01/2003","INSPECTION_END_DT":"12/24/2003","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"15.5","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2003-10-01"},{"SOURCE_ROW_NUMBER":"452659","EVENT_NO":"4104329","INSPECTION_BEGIN_DT":"09/18/2003","INSPECTION_END_DT":"10/15/2003","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.25","SUM_TOTAL_ON_SITE_HOURS":"2.25","sourceDate":"2003-09-18"},{"SOURCE_ROW_NUMBER":"51483","EVENT_NO":"4103229","INSPECTION_BEGIN_DT":"08/27/2003","INSPECTION_END_DT":"08/27/2003","ACTIVITY_CODE":"CED","ACTIVITY":"RESP DUST TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2003-08-27"},{"SOURCE_ROW_NUMBER":"1097096","EVENT_NO":"4100162","INSPECTION_BEGIN_DT":"07/03/2003","INSPECTION_END_DT":"09/30/2003","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"52","SUM_TOTAL_ON_SITE_HOURS":"17.5","sourceDate":"2003-07-03"},{"SOURCE_ROW_NUMBER":"299539","EVENT_NO":"4103218","INSPECTION_BEGIN_DT":"06/27/2003","INSPECTION_END_DT":"06/27/2003","ACTIVITY_CODE":"CED","ACTIVITY":"RESP DUST TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2003-06-27"},{"SOURCE_ROW_NUMBER":"351940","EVENT_NO":"5982202","INSPECTION_BEGIN_DT":"06/24/2003","INSPECTION_END_DT":"06/24/2003","ACTIVITY_CODE":"CDB","ACTIVITY":"ACCIDENT PREVENTION SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2003-06-24"},{"SOURCE_ROW_NUMBER":"938430","EVENT_NO":"4103216","INSPECTION_BEGIN_DT":"05/22/2003","INSPECTION_END_DT":"03/31/2005","ACTIVITY_CODE":"CED","ACTIVITY":"RESP DUST TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2003-05-22"},{"SOURCE_ROW_NUMBER":"836685","EVENT_NO":"4100160","INSPECTION_BEGIN_DT":"05/20/2003","INSPECTION_END_DT":"06/17/2003","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"65.5","SUM_TOTAL_ON_SITE_HOURS":"30","sourceDate":"2003-05-20"},{"SOURCE_ROW_NUMBER":"461626","EVENT_NO":"5982205","INSPECTION_BEGIN_DT":"05/12/2003","INSPECTION_END_DT":"05/15/2003","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11.5","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2003-05-12"},{"SOURCE_ROW_NUMBER":"773597","EVENT_NO":"4103213","INSPECTION_BEGIN_DT":"04/24/2003","INSPECTION_END_DT":"04/25/2003","ACTIVITY_CODE":"CED","ACTIVITY":"RESP DUST TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2003-04-24"},{"SOURCE_ROW_NUMBER":"249578","EVENT_NO":"4100815","INSPECTION_BEGIN_DT":"01/02/2003","INSPECTION_END_DT":"01/02/2003","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2003-01-02"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":9,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2003-Q3":{"hours":0,"employees":0,"production":0},"2003-Q1":{"hours":10465,"employees":13,"production":37941},"2002-Q4":{"hours":10347,"employees":18,"production":33575},"2002-Q3":{"hours":4941,"employees":11,"production":8528},"2002-Q2":{"hours":455,"employees":5,"production":859},"2002-Q1":{"hours":0,"employees":0,"production":0},"2000-Q2":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":2,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002":{"hours":15743,"employees":11,"production":42962},"2003":{"hours":10465,"employees":13,"production":37941}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":17,"firstDate":"2002-06-25","lastDate":"2003-07-23","metrics":{"ss":5,"amountDue":968,"contested":0,"amountPaid":968,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":968},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2801526","VIOLATION_NO":"4892698","VIOLATION_ISSUE_DT":"07/23/2003","SIG_SUB":"N","PART_SECTION":"75.333(d)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/01/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2003-07-23"},{"SOURCE_ROW_NUMBER":"2801523","VIOLATION_NO":"4892696","VIOLATION_ISSUE_DT":"06/05/2003","SIG_SUB":"Y","PART_SECTION":"75.1103-5(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/05/2003","PROPOSED_PENALTY":"75","AMOUNT_DUE":"75","AMOUNT_PAID":"75","CONTESTED_IND":"N","sourceDate":"2003-06-05"},{"SOURCE_ROW_NUMBER":"2801522","VIOLATION_NO":"4892695","VIOLATION_ISSUE_DT":"06/05/2003","SIG_SUB":"N","PART_SECTION":"75.1202","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/05/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2003-06-05"},{"SOURCE_ROW_NUMBER":"2801521","VIOLATION_NO":"4892693","VIOLATION_ISSUE_DT":"05/23/2003","SIG_SUB":"N","PART_SECTION":"72.630(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/23/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2003-05-23"},{"SOURCE_ROW_NUMBER":"2801520","VIOLATION_NO":"4892692","VIOLATION_ISSUE_DT":"05/21/2003","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/21/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2003-05-21"},{"SOURCE_ROW_NUMBER":"2801519","VIOLATION_NO":"4892691","VIOLATION_ISSUE_DT":"05/21/2003","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/21/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2003-05-21"},{"SOURCE_ROW_NUMBER":"2801533","VIOLATION_NO":"4189076","VIOLATION_ISSUE_DT":"01/02/2003","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/02/2003","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2003-01-02"},{"SOURCE_ROW_NUMBER":"2801532","VIOLATION_NO":"4893323","VIOLATION_ISSUE_DT":"11/12/2002","SIG_SUB":"N","PART_SECTION":"77.701","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/12/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-11-12"},{"SOURCE_ROW_NUMBER":"2801531","VIOLATION_NO":"4893322","VIOLATION_ISSUE_DT":"11/06/2002","SIG_SUB":"Y","PART_SECTION":"75.523-1(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/06/2002","PROPOSED_PENALTY":"66","AMOUNT_DUE":"66","AMOUNT_PAID":"66","CONTESTED_IND":"N","sourceDate":"2002-11-06"},{"SOURCE_ROW_NUMBER":"2801530","VIOLATION_NO":"4893321","VIOLATION_ISSUE_DT":"10/01/2002","SIG_SUB":"N","PART_SECTION":"75.1715","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"4","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/01/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-10-01"},{"SOURCE_ROW_NUMBER":"2801529","VIOLATION_NO":"7218382","VIOLATION_ISSUE_DT":"09/19/2002","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/19/2002","PROPOSED_PENALTY":"76","AMOUNT_DUE":"76","AMOUNT_PAID":"76","CONTESTED_IND":"N","sourceDate":"2002-09-19"},{"SOURCE_ROW_NUMBER":"2801528","VIOLATION_NO":"7218381","VIOLATION_ISSUE_DT":"09/18/2002","SIG_SUB":"N","PART_SECTION":"77.208(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/18/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-09-18"}]}],"safety":{"href":"/api/v1/mines/4608828/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4608828/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1103-5","heading":"Automatic fire warning devices; actions and response.","id":"75.1103-5","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103-5","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) When the carbon monoxide level reaches 10 parts per million above the established ambient level at any sensor location, automatic fire sensor and warning device systems shall provide an effective warning signal at the following locations:\n\n(1) At working sections and other work locations where miners may be endangered from a fire in the belt entry.\n\n(2) At a manned surface location where personnel have an assigned post of duty. The manned surface location must have:\n\n(i) A telephone or equivalent communication with all miners who may be endangered and\n\n(ii) A map or schematic that shows the locations of sensors, and the intended air flow direction at these locations. This map or schematic must be updated within 24 hours of any change in this information.\n\n(3) The automatic fire sensor and warning device system shall be monitored for a period of 4 hours after the belt is stopped, unless an examination for hot rollers and fire is made as prescribed in § 75.1103-4(e).\n\n(b) The fire sensor and warning device system shall include a means for rapid evaluation of electrical short and open circuits, ground faults, pneumatic leaks, or other defect detrimental to its proper operational condition.\n\n(c) Automatic fire sensor and warning devices shall include a manual reset feature.\n\n(d) When a malfunction or warning signal is received at the manned surface location, the sensors that are activated must be identified and appropriate personnel immediately notified.\n\n(e) Upon notification of a malfunction or warning signal, appropriate personnel must immediately initiate an investigation to determine the cause of the malfunction or warning signal and take the required actions set forth in paragraph (f) of this section.\n\n(f) If any sensor indicates a warning, the following actions must be taken unless the mine operator determines that the signal does not present a hazard to miners:\n\n(1) Appropriate personnel must notify miners in affected working sections, in affected areas where mechanized mining equipment is being installed or removed, and at other locations specified in the approved mine emergency evacuation and firefighting program of instruction; and\n\n(2) All miners in the affected areas, unless assigned emergency response duties, must be immediately withdrawn to a safe location identified in the mine emergency evacuation and firefighting program of instruction.\n\n(g) If the warning signal will be activated during calibration of sensors, personnel manning the surface location must be notified prior to and upon completion of calibration. Affected working sections, areas where mechanized mining equipment is being installed or removed, or other areas designated in the approved emergency evacuation and firefighting program of instruction must be notified at the beginning and completion of calibration.\n\n(h) If any fire detection component becomes inoperative, immediate action must be taken to repair the component. While repairs are being made, operation of the belt may continue if the following requirements are met:\n\n(1) If one sensor becomes inoperative, a trained person must continuously monitor for carbon monoxide at the inoperative sensor;\n\n(2) If two or more adjacent sensors become inoperative, trained persons must patrol and continuously monitor the affected areas for carbon monoxide so that they will be traveled each hour in their entirety. Alternatively, a trained person must be stationed at each inoperative sensor to monitor for carbon monoxide;\n\n(3) If the complete fire detection system becomes inoperative, trained persons must patrol and continuously monitor the affected areas for carbon monoxide so that they will be traveled each hour in their entirety;\n\n(4) Trained persons who conduct monitoring under this section must have two-way voice communication capability, at intervals not to exceed 2,000 feet, and must report carbon monoxide concentrations to the surface at intervals not to exceed one hour;\n\n(5) Trained persons who conduct monitoring under this section must immediately report to the surface any concentration of carbon monoxide that reaches 10 parts per million above the established ambient level, unless the mine operator knows that the source of the carbon monoxide does not present a hazard to miners; and\n\n(6) Handheld detectors used to monitor the belt entry under this section must have a detection level equivalent to that of the system's carbon monoxide sensors.\n\n[37 FR 16545, Aug. 16, 1972, as amended at 73 FR 80615, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1202","heading":"Temporary notations, revisions, and supplements.","id":"75.1202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-M/section-75.1202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"M","subpartHeading":"Subpart M—Maps","text":"[Statutory Provisions]\n\nSuch map shall be kept up-to-date by temporary notations and such map shall be revised and supplemented at intervals prescribed by the Secretary on the basis of a survey made or certified by such engineer or surveyor.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 72.630","heading":"Drill dust control at underground areas of underground mines.","id":"72.630","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-72/subpart-E/section-72.630","part":"72","partHeading":"PART 72—HEALTH STANDARDS FOR COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Miscellaneous","text":"(a) Dust resulting from drilling in rock shall be controlled by use of permissible dust collectors, or by water, or water with a wetting agent, or by ventilation, or by any other method or device approved by the Secretary that is as effective in controlling the dust.\n\n(b) Dust collectors. Dust collectors shall be maintained in permissible and operating condition. Dust collectors approved under Part 33—Dust Collectors for Use in Connection with Rock Drilling in Coal Mines of this title or under Bureau of Mines Schedule 25B are permissible dust collectors for the purpose of this section.\n\n(c) Water control. Water used to control dust from drilling rock shall be applied through a hollow drill steel or stem or by the flooding of vertical drill holes in the floor.\n\n(d) Ventilation control. To adequately control dust from drilling rock, the air current shall be so directed that the dust is readily dispersed and carried away from the drill operator or any other miners in the area.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":4},{"chapter":"I","heading":"Grounding metallic frames, casings, and other enclosures of electric equipment.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-H/section-77.701","part":"77","subchapter":"O","subpart":"H","id":"77.701","citation":"30 CFR 77.701","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Deenergization of self-propelled electric face equipment installation requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-1","part":"75","subchapter":"O","subpart":"F","id":"75.523-1","citation":"30 CFR 75.523-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Identification check system.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1715","part":"75","subchapter":"O","subpart":"R","id":"75.1715","citation":"30 CFR 75.1715","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.208","heading":"Storage of materials.","id":"77.208","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.208","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Materials shall be stored and stacked in a manner which minimizes stumbling or fall-of-material hazards.\n\n(b) Materials that can create hazards if accidentally liberated from their containers shall be stored in a manner that minimizes the dangers.\n\n(c) Containers holding hazardous materials must be of a type approved for such use by recognized agencies.\n\n(d) Compressed and liquid gas cylinders shall be secured in a safe manner.\n\n(e) Valves on compressed gas cylinders shall be protected by covers when being transported or stored, and by a safe location when the cylinders are in use.\n\n[36 FR 9364, May 22, 1971, as amended at 67 FR 42389, June 21, 2002]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4608828","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}