{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4608787","name":"Jerry Fork Eagle","status":"Active","status_date":"2020-04-27","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Nicholas","nearest_town":"Drennen","operator_id":"0146435","operator_name":"Nicholas Contura LLC","controller_id":"0127321","controller_name":"Alpha Metallurgical Resources Inc","district":"C04","office":"Summersville WV Field Office","employees":89,"latitude":38.298611,"longitude":-80.990556},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":30823},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4608787","name":"Jerry Fork Eagle"},"operator":{"type":"operator","id":"0146435","name":"Nicholas Contura LLC"},"controller":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"mine","id":"4608787","name":"Jerry Fork Eagle"},"validFrom":"1997-10-20","validTo":"2011-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608787|C02508|1997-10-20|2011-05-31"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24027","name":"Alex Energy Inc"},"object":{"type":"mine","id":"4608787","name":"Jerry Fork Eagle"},"validFrom":"1999-07-01","validTo":"2016-07-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608787|P24027|1999-07-01|2016-07-25"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"P24027","name":"Alex Energy Inc"},"validFrom":"1999-07-01","validTo":"2011-05-31","current":false,"derived":true,"evidenceMineId":"4608787","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608787|P24027|1999-07-01|C02508|1997-10-20|59491"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"4608787","name":"Jerry Fork Eagle"},"validFrom":"2011-06-01","validTo":"2016-07-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608787|0041211|2011-06-01|2016-07-25"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P24027","name":"Alex Energy Inc"},"validFrom":"2011-06-01","validTo":"2016-07-25","current":false,"derived":true,"evidenceMineId":"4608787","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608787|P24027|1999-07-01|0041211|2011-06-01|2139"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0146435","name":"Nicholas Contura LLC"},"object":{"type":"mine","id":"4608787","name":"Jerry Fork Eagle"},"validFrom":"2016-07-26","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608787|0146435|2016-07-26|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"mine","id":"4608787","name":"Jerry Fork Eagle"},"validFrom":"2016-07-26","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608787|0127321|2016-07-26|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"operator","id":"0146435","name":"Nicholas Contura LLC"},"validFrom":"2016-07-26","validTo":null,"current":true,"derived":true,"evidenceMineId":"4608787","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608787|0146435|2016-07-26|0127321|2016-07-26|24736"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"mine","id":"4608787","name":"Jerry Fork Eagle"},"validFrom":"2016-07-26","validTo":"2018-11-08","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608787|0127923|2016-07-26|2018-11-08"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"operator","id":"P24027","name":"Alex Energy Inc"},"validFrom":"2016-07-26","validTo":"2016-07-25","current":false,"derived":true,"evidenceMineId":"4608787","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608787|P24027|1999-07-01|0127923|2016-07-26|25235"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"mine","id":"4608787","name":"Jerry Fork Eagle"},"validFrom":"2018-11-09","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608787|0127321|2018-11-09|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"operator","id":"P24027","name":"Alex Energy Inc"},"validFrom":"2018-11-09","validTo":"2016-07-25","current":false,"derived":true,"evidenceMineId":"4608787","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608787|P24027|1999-07-01|0127321|2018-11-09|24870"}}],"coverage":{"historyRecords":5,"edgeCount":12,"intervalAnomalies":2,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":196,"firstDate":"2000-01-07","lastDate":"2026-01-15","metrics":{"daysLost":7052,"injuries":158,"fatalities":0,"recentRows":48,"restrictedDays":425,"contractorRecords":27},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"158721","DOCUMENT_NO":"220260920017","ACCIDENT_DT":"01/15/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"On 1/25/2026 EE stated that while EE was bending a 5' bolt EE felt a pain in EE's right shoulder. EE was granted a full release and returned to work.  On 3/30/2026 Mine Management was informed that EE started Physical Therapy for EE's shoulder.","sourceDate":"2026-01-15"},{"SOURCE_ROW_NUMBER":"193064","DOCUMENT_NO":"220260610015","ACCIDENT_DT":"01/12/2026","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Section foreman, Bullgang foreman, Labor foreman, Leadman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Miner has been diagnosed with Pneumoconiosis.","sourceDate":"2026-01-12"},{"SOURCE_ROW_NUMBER":"274779","DOCUMENT_NO":"220253280017","ACCIDENT_DT":"11/17/2025","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee stated that EE swung the drill station in to set the inside bolt when a bolt laying in the tray became fouled and sprung up and struck EE in the chin.","sourceDate":"2025-11-17"},{"SOURCE_ROW_NUMBER":"193060","DOCUMENT_NO":"220253170352","ACCIDENT_DT":"10/08/2025","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"EMPLOYEE WAS WORKING ON INSTALLING A BELT SCRAPER ON THE 11c HEAD, WHEN THE OUTBY BELT UNEXPECTEDLY STARTED.  THE BELT TRANSPORTED THE EMPLOYEE APPROXIMATELY 30 FEET BEFORE IT WAS STOPPED BY PULL SWITCH.  RESULTED IN A FRACTURED ANKLE.","sourceDate":"2025-10-08"},{"SOURCE_ROW_NUMBER":"132708","DOCUMENT_NO":"220252370049","ACCIDENT_DT":"08/22/2025","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee stated that while they were drilling the outside bolt hole with the starter steel, a piece of rock that measure 6\"x 8\"x 1/2\" fell out and struck them on the right forearm. This resulted in a laceration.","sourceDate":"2025-08-22"},{"SOURCE_ROW_NUMBER":"270530","DOCUMENT_NO":"220253170465","ACCIDENT_DT":"06/21/2025","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"employee was using grinder and grinder caught on gloves cutting right pinky finger on first knuckle, Finger was almost cut off. the cut did cut the tendons and was taken off work. Each employee will now be trained properly trained on using said machine, do not use any equipment without proper guard in place","sourceDate":"2025-06-21"},{"SOURCE_ROW_NUMBER":"223211","DOCUMENT_NO":"220253170306","ACCIDENT_DT":"06/21/2025","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"40","NARRATIVE":"using grinder and caught gloves with grinder cutting right pinky finger on first knuckle","sourceDate":"2025-06-21"},{"SOURCE_ROW_NUMBER":"16726","DOCUMENT_NO":"220251740026","ACCIDENT_DT":"06/21/2025","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Removed lagging from drive roller and was buffering and cleaning up drum to install new lagging grinder got caught and kicked back resulting in laceration to pinky finger on right hand and small cut on ring finger .","sourceDate":"2025-06-21"},{"SOURCE_ROW_NUMBER":"158720","DOCUMENT_NO":"220250900030","ACCIDENT_DT":"03/26/2025","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE was assisting in making a belt splice when a piece of metal splintered off a coworker's hammer and embedded in EE's forehead.","sourceDate":"2025-03-26"},{"SOURCE_ROW_NUMBER":"150172","DOCUMENT_NO":"220250520023","ACCIDENT_DT":"02/18/2025","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE stated that was striking on a chisel with a hammer when the chisel flew back and struck EE in the left eyebrow, causing a laceration.","sourceDate":"2025-02-18"},{"SOURCE_ROW_NUMBER":"59662","DOCUMENT_NO":"220242500027","ACCIDENT_DT":"08/28/2024","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"STRIKING OR BUMPING","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Scoop tram operator, Load/Haul/Dump operator","NO_INJURIES":"1","DAYS_LOST":"64","NARRATIVE":"EE stated that as EE was walking to the section EE hit their head on a fly board.","sourceDate":"2024-08-28"},{"SOURCE_ROW_NUMBER":"184539","DOCUMENT_NO":"220242360020","ACCIDENT_DT":"08/20/2024","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee stated that they reached down to move a 5-gallon oil can off the CM cable. While grabbing the can, they cut their right index finger. The laceration required 5 sutures.","sourceDate":"2024-08-20"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2020-04-27","lastDate":"2020-04-27","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":2522,"firstDate":"2000-02-08","lastDate":"2026-08-25","metrics":{"ss":407,"delinquent":2374,"recentRows":1180,"paidPenalty":1003845.8,"proposedPenalty":1129136,"currentAssessment":1028003.25},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2925675","VIOLATION_NO":"5027228","ISSUE_DT":"08/25/2026","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"226.00","CURRENT_ASSESSMENT_AMT":"226.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-25"},{"SOURCE_ROW_NUMBER":"2925688","VIOLATION_NO":"9847001","ISSUE_DT":"08/20/2026","CFR_STANDARD_CD":"75.380(d)(7)(vi)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-20"},{"SOURCE_ROW_NUMBER":"2925687","VIOLATION_NO":"5183556","ISSUE_DT":"08/20/2026","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"366.00","CURRENT_ASSESSMENT_AMT":"366.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-20"},{"SOURCE_ROW_NUMBER":"2925686","VIOLATION_NO":"5183555","ISSUE_DT":"08/20/2026","CFR_STANDARD_CD":"75.1107-4(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-20"},{"SOURCE_ROW_NUMBER":"2925685","VIOLATION_NO":"5183554","ISSUE_DT":"08/20/2026","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1037.00","CURRENT_ASSESSMENT_AMT":"1037.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-20"},{"SOURCE_ROW_NUMBER":"2925684","VIOLATION_NO":"5183553","ISSUE_DT":"08/20/2026","CFR_STANDARD_CD":"75.1731(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-20"},{"SOURCE_ROW_NUMBER":"2925683","VIOLATION_NO":"5183552","ISSUE_DT":"08/20/2026","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-20"},{"SOURCE_ROW_NUMBER":"2925682","VIOLATION_NO":"5183551","ISSUE_DT":"08/18/2026","CFR_STANDARD_CD":"75.1732(b)(2)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1126.00","CURRENT_ASSESSMENT_AMT":"1126.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-18"},{"SOURCE_ROW_NUMBER":"2925681","VIOLATION_NO":"5183550","ISSUE_DT":"08/18/2026","CFR_STANDARD_CD":"75.1731(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-18"},{"SOURCE_ROW_NUMBER":"2925680","VIOLATION_NO":"5183549","ISSUE_DT":"08/18/2026","CFR_STANDARD_CD":"75.1731(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-18"},{"SOURCE_ROW_NUMBER":"2925679","VIOLATION_NO":"5183548","ISSUE_DT":"08/17/2026","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1126.00","CURRENT_ASSESSMENT_AMT":"1126.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-17"},{"SOURCE_ROW_NUMBER":"2925678","VIOLATION_NO":"5183547","ISSUE_DT":"08/17/2026","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"366.00","CURRENT_ASSESSMENT_AMT":"366.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-17"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":275,"firstDate":"2003-07-11","lastDate":"2026-07-22","metrics":{"appeals":0,"decisions":275,"recentRows":75,"decisionPenalty":261197.25,"originalPenalty":366930},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"462772","VIOLATION_NO":"5023473","DOCKET_NO":"WEVA 2026-0164","DECISION_DT":"07/22/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3184.00","DECISION_PENALTY_AMT":"1431.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-07-22"},{"SOURCE_ROW_NUMBER":"168617","VIOLATION_NO":"5023442","DOCKET_NO":"WEVA 2026-0164","DECISION_DT":"07/22/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"15768.00","DECISION_PENALTY_AMT":"15768.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-07-22"},{"SOURCE_ROW_NUMBER":"461068","VIOLATION_NO":"5023447","DOCKET_NO":"WEVA 2026-0112","DECISION_DT":"02/23/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"151.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-02-23"},{"SOURCE_ROW_NUMBER":"168362","VIOLATION_NO":"5023445","DOCKET_NO":"WEVA 2026-0112","DECISION_DT":"02/23/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"883.00","DECISION_PENALTY_AMT":"883.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-02-23"},{"SOURCE_ROW_NUMBER":"460670","VIOLATION_NO":"9844188","DOCKET_NO":"WEVA 2026-0068","DECISION_DT":"02/13/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2133.00","DECISION_PENALTY_AMT":"959.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Young","sourceDate":"2026-02-13"},{"SOURCE_ROW_NUMBER":"166414","VIOLATION_NO":"5024390","DOCKET_NO":"WEVA 2025-0492","DECISION_DT":"08/26/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"642.00","DECISION_PENALTY_AMT":"642.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2025-08-26"},{"SOURCE_ROW_NUMBER":"166413","VIOLATION_NO":"5024386","DOCKET_NO":"WEVA 2025-0492","DECISION_DT":"08/26/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"7267.00","DECISION_PENALTY_AMT":"1320.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2025-08-26"},{"SOURCE_ROW_NUMBER":"166412","VIOLATION_NO":"5020491","DOCKET_NO":"WEVA 2025-0492","DECISION_DT":"08/26/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"151.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2025-08-26"},{"SOURCE_ROW_NUMBER":"166133","VIOLATION_NO":"5024384","DOCKET_NO":"WEVA 2025-0492","DECISION_DT":"08/26/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2782.00","DECISION_PENALTY_AMT":"2782.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2025-08-26"},{"SOURCE_ROW_NUMBER":"166132","VIOLATION_NO":"5024383","DOCKET_NO":"WEVA 2025-0492","DECISION_DT":"08/26/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1467.00","DECISION_PENALTY_AMT":"1467.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2025-08-26"},{"SOURCE_ROW_NUMBER":"458297","VIOLATION_NO":"9849975","DOCKET_NO":"WEVA 2025-0390","DECISION_DT":"07/28/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"592.00","DECISION_PENALTY_AMT":"592.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2025-07-28"},{"SOURCE_ROW_NUMBER":"458296","VIOLATION_NO":"9849970","DOCKET_NO":"WEVA 2025-0390","DECISION_DT":"07/28/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"151.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2025-07-28"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":17463,"firstDate":"2000-02-09","lastDate":"2026-10-08","metrics":{"recentRows":9725,"cpdmSamples":13813,"voidSamples":4120,"validSamples":13343,"maxConcentration":262.942,"concentrationTotal":9767.625},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2944707","SMP_TAKEN_DT":"10/8/2026","CONC":".755","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2859796","SMP_TAKEN_DT":"10/8/2026","CONC":".422","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2858814","SMP_TAKEN_DT":"10/8/2026","CONC":".048","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2261807","SMP_TAKEN_DT":"10/8/2026","CONC":".157","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2687957","SMP_TAKEN_DT":"10/6/2026","CONC":".043","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2431795","SMP_TAKEN_DT":"10/6/2026","CONC":".015","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2346719","SMP_TAKEN_DT":"10/5/2026","CONC":".575","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"MULTIPLE SAMPLES SAME SHIFT","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"2262962","SMP_TAKEN_DT":"10/5/2026","CONC":".049","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"2006822","SMP_TAKEN_DT":"10/5/2026","CONC":".7","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"1920717","SMP_TAKEN_DT":"10/5/2026","CONC":".898","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"1751961","SMP_TAKEN_DT":"10/5/2026","CONC":".022","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"2432914","SMP_TAKEN_DT":"10/2/2026","CONC":".998","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-02"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":83,"firstDate":"2000-11-09","lastDate":"2026-09-16","metrics":{"linkedIssuances":83},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":270,"firstDate":"2007-08-07","lastDate":"2025-12-08","metrics":{"decisions":270,"ssChanged":73,"recentRows":74,"decisionPenalty":249347.25,"proposedPenalty":351430},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"337647","CITATION_NO":"5023473","CITATION_ISSUE_DT":"12/08/2025","DOCKET_NO":"WEVA 2026-0164","DECISION_DT":"07/22/2026","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3184.00","DECISION_PENALTY_AMT":"1431.00","sourceDate":"2025-12-08"},{"SOURCE_ROW_NUMBER":"337506","CITATION_NO":"9844188","CITATION_ISSUE_DT":"10/29/2025","DOCKET_NO":"WEVA 2026-0068","DECISION_DT":"02/13/2026","CFR_STANDARD_CODE":"75.1403","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2133.00","DECISION_PENALTY_AMT":"959.00","sourceDate":"2025-10-29"},{"SOURCE_ROW_NUMBER":"337204","CITATION_NO":"5023447","CITATION_ISSUE_DT":"10/20/2025","DOCKET_NO":"WEVA 2026-0112","DECISION_DT":"02/23/2026","CFR_STANDARD_CODE":"50.20(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"151.00","sourceDate":"2025-10-20"},{"SOURCE_ROW_NUMBER":"224445","CITATION_NO":"5023445","CITATION_ISSUE_DT":"10/20/2025","DOCKET_NO":"WEVA 2026-0112","DECISION_DT":"02/23/2026","CFR_STANDARD_CODE":"75.1725(c)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"883.00","DECISION_PENALTY_AMT":"883.00","sourceDate":"2025-10-20"},{"SOURCE_ROW_NUMBER":"54240","CITATION_NO":"5023442","CITATION_ISSUE_DT":"10/20/2025","DOCKET_NO":"WEVA 2026-0164","DECISION_DT":"07/22/2026","CFR_STANDARD_CODE":"48.11(e)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"15768.00","DECISION_PENALTY_AMT":"15768.00","sourceDate":"2025-10-20"},{"SOURCE_ROW_NUMBER":"281192","CITATION_NO":"5024390","CITATION_ISSUE_DT":"06/02/2025","DOCKET_NO":"WEVA 2025-0492","DECISION_DT":"08/26/2025","CFR_STANDARD_CODE":"75.370(e)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"642.00","DECISION_PENALTY_AMT":"642.00","sourceDate":"2025-06-02"},{"SOURCE_ROW_NUMBER":"451210","CITATION_NO":"5024386","CITATION_ISSUE_DT":"05/22/2025","DOCKET_NO":"WEVA 2025-0492","DECISION_DT":"08/26/2025","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"7267.00","DECISION_PENALTY_AMT":"1320.00","sourceDate":"2025-05-22"},{"SOURCE_ROW_NUMBER":"448577","CITATION_NO":"5024383","CITATION_ISSUE_DT":"05/20/2025","DOCKET_NO":"WEVA 2025-0492","DECISION_DT":"08/26/2025","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1467.00","DECISION_PENALTY_AMT":"1467.00","sourceDate":"2025-05-20"},{"SOURCE_ROW_NUMBER":"393601","CITATION_NO":"5024384","CITATION_ISSUE_DT":"05/20/2025","DOCKET_NO":"WEVA 2025-0492","DECISION_DT":"08/26/2025","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"2782.00","DECISION_PENALTY_AMT":"2782.00","sourceDate":"2025-05-20"},{"SOURCE_ROW_NUMBER":"111925","CITATION_NO":"5020491","CITATION_ISSUE_DT":"05/08/2025","DOCKET_NO":"WEVA 2025-0492","DECISION_DT":"08/26/2025","CFR_STANDARD_CODE":"75.320(b)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"151.00","sourceDate":"2025-05-08"},{"SOURCE_ROW_NUMBER":"224377","CITATION_NO":"5024354","CITATION_ISSUE_DT":"03/21/2025","DOCKET_NO":"WEVA 2025-0390","DECISION_DT":"07/28/2025","CFR_STANDARD_CODE":"75.1714-7(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"2133.00","DECISION_PENALTY_AMT":"714.00","sourceDate":"2025-03-21"},{"SOURCE_ROW_NUMBER":"335319","CITATION_NO":"5024353","CITATION_ISSUE_DT":"03/18/2025","DOCKET_NO":"WEVA 2025-0390","DECISION_DT":"07/28/2025","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"151.00","DECISION_PENALTY_AMT":"151.00","sourceDate":"2025-03-18"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":4260,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":20,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":926,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":20,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":5,"firstDate":"1999-07-01","lastDate":"2016-07-26","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":4},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":590,"firstDate":"2000-01-05","lastDate":"2026-10-06","metrics":{"inspectors":1185,"recentRows":324,"onSiteHours":32138.75,"inspectionHours":45613.5,"inspectionSamples":2876},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"670736","EVENT_NO":"F00B82D","INSPECTION_BEGIN_DT":"10/06/2026","INSPECTION_END_DT":"10/06/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"0","SUM_TOTAL_INSP_HOURS":"0","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"460029","EVENT_NO":"F02D0DD","INSPECTION_BEGIN_DT":"10/01/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"35.25","SUM_TOTAL_ON_SITE_HOURS":"21","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"648318","EVENT_NO":"F0291FF","INSPECTION_BEGIN_DT":"09/28/2026","INSPECTION_END_DT":"09/28/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2026-09-28"},{"SOURCE_ROW_NUMBER":"438814","EVENT_NO":"F02D0DC","INSPECTION_BEGIN_DT":"09/25/2026","INSPECTION_END_DT":"09/25/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2026-09-25"},{"SOURCE_ROW_NUMBER":"195802","EVENT_NO":"F02D0DB","INSPECTION_BEGIN_DT":"09/21/2026","INSPECTION_END_DT":"09/21/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2026-09-21"},{"SOURCE_ROW_NUMBER":"566335","EVENT_NO":"F0291FD","INSPECTION_BEGIN_DT":"09/14/2026","INSPECTION_END_DT":"09/14/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2026-09-14"},{"SOURCE_ROW_NUMBER":"144985","EVENT_NO":"F0291FC","INSPECTION_BEGIN_DT":"09/08/2026","INSPECTION_END_DT":"09/08/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2026-09-08"},{"SOURCE_ROW_NUMBER":"540713","EVENT_NO":"F0291FB","INSPECTION_BEGIN_DT":"09/03/2026","INSPECTION_END_DT":"09/03/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-09-03"},{"SOURCE_ROW_NUMBER":"190017","EVENT_NO":"F0291FA","INSPECTION_BEGIN_DT":"08/31/2026","INSPECTION_END_DT":"08/31/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2026-08-31"},{"SOURCE_ROW_NUMBER":"197919","EVENT_NO":"F00B82C","INSPECTION_BEGIN_DT":"08/24/2026","INSPECTION_END_DT":"08/24/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"11","sourceDate":"2026-08-24"},{"SOURCE_ROW_NUMBER":"177691","EVENT_NO":"F00B82B","INSPECTION_BEGIN_DT":"08/19/2026","INSPECTION_END_DT":"08/19/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"12","sourceDate":"2026-08-19"},{"SOURCE_ROW_NUMBER":"637091","EVENT_NO":"F02D0D8","INSPECTION_BEGIN_DT":"08/18/2026","INSPECTION_END_DT":"08/18/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"15","SUM_TOTAL_ON_SITE_HOURS":"13.5","sourceDate":"2026-08-18"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":260,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2026-Q2":{"hours":88652,"employees":146,"production":120276},"2026-Q1":{"hours":91995,"employees":145,"production":130460},"2025-Q4":{"hours":80788,"employees":144,"production":106597},"2025-Q3":{"hours":86624,"employees":143,"production":128148},"2025-Q2":{"hours":91691,"employees":158,"production":140563},"2025-Q1":{"hours":118093,"employees":181,"production":145107},"2024-Q4":{"hours":110158,"employees":189,"production":133004},"2024-Q3":{"hours":116742,"employees":192,"production":173358},"2024-Q2":{"hours":120215,"employees":196,"production":160916},"2024-Q1":{"hours":130806,"employees":198,"production":195942},"2023-Q4":{"hours":110955,"employees":191,"production":149070},"2023-Q3":{"hours":114346,"employees":186,"production":166929}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":56,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017":{"hours":253600,"employees":112,"production":516508},"2018":{"hours":275213,"employees":117,"production":549688},"2019":{"hours":305838,"employees":126,"production":559834},"2020":{"hours":335098,"employees":146,"production":827027},"2021":{"hours":390926,"employees":159,"production":842072},"2022":{"hours":433414,"employees":174,"production":794984},"2023":{"hours":456580,"employees":186,"production":690515},"2024":{"hours":477921,"employees":194,"production":663220},"2025":{"hours":377196,"employees":157,"production":520415},"2026":{"hours":180647,"employees":146,"production":250736}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":492,"firstDate":"2000-03-15","lastDate":"2026-08-26","metrics":{"recentRows":174,"doseOver100":145,"actDoseTotal":39034,"pelDoseTotal":28019},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"244059","EVENT_NO":"F007E31","SURVEY_DATE":"08/26/2026","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"72","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"244058","EVENT_NO":"F007E31","SURVEY_DATE":"08/26/2026","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"63","PEL_DOSE_90":"33","SURVEY_TYPE":"I","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"244057","EVENT_NO":"F007E31","SURVEY_DATE":"08/26/2026","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"110","PEL_DOSE_90":"89","SURVEY_TYPE":"I","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"244064","EVENT_NO":"F007E31","SURVEY_DATE":"07/30/2026","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"129","PEL_DOSE_90":"143","SURVEY_TYPE":"I","sourceDate":"2026-07-30"},{"SOURCE_ROW_NUMBER":"244063","EVENT_NO":"F007E31","SURVEY_DATE":"07/30/2026","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"40","ACT_DOSE_85":"54","PEL_DOSE_90":"28","SURVEY_TYPE":"I","sourceDate":"2026-07-30"},{"SOURCE_ROW_NUMBER":"244062","EVENT_NO":"F007E31","SURVEY_DATE":"07/30/2026","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"59","PEL_DOSE_90":"34","SURVEY_TYPE":"I","sourceDate":"2026-07-30"},{"SOURCE_ROW_NUMBER":"244061","EVENT_NO":"F007E31","SURVEY_DATE":"07/30/2026","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"78","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2026-07-30"},{"SOURCE_ROW_NUMBER":"244060","EVENT_NO":"F007E31","SURVEY_DATE":"07/30/2026","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"126","PEL_DOSE_90":"99","SURVEY_TYPE":"I","sourceDate":"2026-07-30"},{"SOURCE_ROW_NUMBER":"244056","EVENT_NO":"F007E20","SURVEY_DATE":"02/12/2026","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","ACT_DOSE_85":"68","PEL_DOSE_90":"39","SURVEY_TYPE":"I","sourceDate":"2026-02-12"},{"SOURCE_ROW_NUMBER":"244055","EVENT_NO":"F007E20","SURVEY_DATE":"02/12/2026","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"74","PEL_DOSE_90":"41","SURVEY_TYPE":"I","sourceDate":"2026-02-12"},{"SOURCE_ROW_NUMBER":"244054","EVENT_NO":"F007E20","SURVEY_DATE":"02/12/2026","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"82","PEL_DOSE_90":"51","SURVEY_TYPE":"I","sourceDate":"2026-02-12"},{"SOURCE_ROW_NUMBER":"244053","EVENT_NO":"F007E20","SURVEY_DATE":"02/12/2026","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"13","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2026-02-12"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":865,"firstDate":"2000-01-24","lastDate":"2026-08-28","metrics":{"recentRows":430,"voidSamples":43,"maxQuartzPct":36,"validSamples":822,"quartzPctTotal":5557},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"129846","CASSETTE_NO":"58575305","SAMPLE_DT":"08/28/2026","QUARTZ_PCT":"16.3","QUARTZ_MICROGRAMS":"28","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-28"},{"SOURCE_ROW_NUMBER":"125913","CASSETTE_NO":"58575582","SAMPLE_DT":"08/05/2026","QUARTZ_PCT":"11.3","QUARTZ_MICROGRAMS":"27","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-05"},{"SOURCE_ROW_NUMBER":"124883","CASSETTE_NO":"58575309","SAMPLE_DT":"08/05/2026","QUARTZ_PCT":"05.7","QUARTZ_MICROGRAMS":"9","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-05"},{"SOURCE_ROW_NUMBER":"124822","CASSETTE_NO":"58575606","SAMPLE_DT":"08/05/2026","QUARTZ_PCT":"06.4","QUARTZ_MICROGRAMS":"12","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-05"},{"SOURCE_ROW_NUMBER":"165244","CASSETTE_NO":"58575563","SAMPLE_DT":"07/30/2026","QUARTZ_PCT":"05.6","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-30"},{"SOURCE_ROW_NUMBER":"109503","CASSETTE_NO":"58575574","SAMPLE_DT":"07/30/2026","QUARTZ_PCT":"08.6","QUARTZ_MICROGRAMS":"19","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-30"},{"SOURCE_ROW_NUMBER":"12905","CASSETTE_NO":"58575555","SAMPLE_DT":"07/30/2026","QUARTZ_PCT":"10.9","QUARTZ_MICROGRAMS":"16","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-30"},{"SOURCE_ROW_NUMBER":"11104","CASSETTE_NO":"58575280","SAMPLE_DT":"07/30/2026","QUARTZ_PCT":"09.0","QUARTZ_MICROGRAMS":"21","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-30"},{"SOURCE_ROW_NUMBER":"6731","CASSETTE_NO":"58575271","SAMPLE_DT":"07/30/2026","QUARTZ_PCT":"12.2","QUARTZ_MICROGRAMS":"47","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-30"},{"SOURCE_ROW_NUMBER":"154117","CASSETTE_NO":"58575277","SAMPLE_DT":"07/28/2026","QUARTZ_PCT":"10.3","QUARTZ_MICROGRAMS":"18","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"CONTROL FILTER INVALID","sourceDate":"2026-07-28"},{"SOURCE_ROW_NUMBER":"21176","CASSETTE_NO":"58575565","SAMPLE_DT":"07/28/2026","QUARTZ_PCT":"06.4","QUARTZ_MICROGRAMS":"22","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"CONTROL FILTER INVALID","sourceDate":"2026-07-28"},{"SOURCE_ROW_NUMBER":"77610","CASSETTE_NO":"58541445","SAMPLE_DT":"06/26/2026","QUARTZ_PCT":"11.0","QUARTZ_MICROGRAMS":"22","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-06-26"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":2558,"firstDate":"2000-02-08","lastDate":"2026-10-06","metrics":{"ss":407,"amountDue":1028003.25,"contested":100,"amountPaid":1003845.8,"recentRows":1194,"section104d":5,"unterminated":2,"proposedPenalty":1129136},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2785522","VIOLATION_NO":"9847002","VIOLATION_ISSUE_DT":"10/06/2026","SIG_SUB":"N","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","CONTESTED_IND":"N","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2785279","VIOLATION_NO":"5027234","VIOLATION_ISSUE_DT":"09/28/2026","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/28/2026","CONTESTED_IND":"N","sourceDate":"2026-09-28"},{"SOURCE_ROW_NUMBER":"2784831","VIOLATION_NO":"5027230","VIOLATION_ISSUE_DT":"09/14/2026","SIG_SUB":"N","PART_SECTION":"75.364(g)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/14/2026","CONTESTED_IND":"N","sourceDate":"2026-09-14"},{"SOURCE_ROW_NUMBER":"2784830","VIOLATION_NO":"5027228","VIOLATION_ISSUE_DT":"08/25/2026","SIG_SUB":"N","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/25/2026","PROPOSED_PENALTY":"226","AMOUNT_DUE":"226","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-08-25"},{"SOURCE_ROW_NUMBER":"2784844","VIOLATION_NO":"9847001","VIOLATION_ISSUE_DT":"08/20/2026","SIG_SUB":"N","PART_SECTION":"75.380(d)(7)(vi)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/20/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-08-20"},{"SOURCE_ROW_NUMBER":"2784843","VIOLATION_NO":"5183556","VIOLATION_ISSUE_DT":"08/20/2026","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/25/2026","PROPOSED_PENALTY":"366","AMOUNT_DUE":"366","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-08-20"},{"SOURCE_ROW_NUMBER":"2784842","VIOLATION_NO":"5183555","VIOLATION_ISSUE_DT":"08/20/2026","SIG_SUB":"N","PART_SECTION":"75.1107-4(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/25/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-08-20"},{"SOURCE_ROW_NUMBER":"2784841","VIOLATION_NO":"5183554","VIOLATION_ISSUE_DT":"08/20/2026","SIG_SUB":"Y","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/20/2026","PROPOSED_PENALTY":"1037","AMOUNT_DUE":"1037","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-08-20"},{"SOURCE_ROW_NUMBER":"2784840","VIOLATION_NO":"5183553","VIOLATION_ISSUE_DT":"08/20/2026","SIG_SUB":"N","PART_SECTION":"75.1731(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/20/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-08-20"},{"SOURCE_ROW_NUMBER":"2784839","VIOLATION_NO":"5183552","VIOLATION_ISSUE_DT":"08/20/2026","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/20/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-08-20"},{"SOURCE_ROW_NUMBER":"2784838","VIOLATION_NO":"5183551","VIOLATION_ISSUE_DT":"08/18/2026","SIG_SUB":"Y","PART_SECTION":"75.1732(b)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/18/2026","PROPOSED_PENALTY":"1126","AMOUNT_DUE":"1126","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-08-18"},{"SOURCE_ROW_NUMBER":"2784837","VIOLATION_NO":"5183550","VIOLATION_ISSUE_DT":"08/18/2026","SIG_SUB":"N","PART_SECTION":"75.1731(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/18/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-08-18"}]}],"safety":{"href":"/api/v1/mines/4608787/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4608787/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":{"averageEmployees":194,"companyType":"Operating Subsidiary","components":[{"averageEmployees":194,"laborHours":477921,"mineType":"Underground","productionTons":663220}],"county":"Nicholas","laborHours":477921,"mineName":"Jerry Fork Eagle","mineType":"Underground","mshaId":"4608787","operatingAddress":"P.O. Box 707, Summersville, WV 26651","operatingCompany":"Nicholas Contura Llc","operationType":"Mine only","productionTons":663220,"reportedRows":1,"sourceUrl":"https://www.eia.gov/coal/data/public/xls/coalpublic2024.xlsx","state":"West Virginia (Southern)","status":"Active","supplyRegion":"Appalachia Central","union":"","year":2024},"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1725","heading":"Machinery and equipment; operation and maintenance.","id":"75.1725","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1725","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.364","heading":"Weekly examination.","id":"75.364","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.364","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Worked-out areas. (1) At least every 7 days, a certified person shall examine unsealed worked-out areas where no pillars have been recovered by traveling to the area of deepest penetration; measuring methane and oxygen concentrations and air quantities and making tests to determine if the air is moving in the proper direction in the area. The locations of measurement points where tests and measurements will be performed shall be included in the mine ventilation plan and shall be adequate in number and location to assure ventilation and air quality in the area. Air quantity measurements shall also be made where the air enters and leaves the worked-out area. An alternative method of evaluating the ventilation of the area may be approved in the ventilation plan.\n\n(2) At least every 7 days, a certified person shall evaluate the effectiveness of bleeder systems required by § 75.334 as follows:\n\n(i) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in its proper direction shall be made where air enters the worked-out area.\n\n(ii) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in the proper direction shall be made immediately before the air enters a return split of air.\n\n(iii) At least one entry of each set of bleeder entries used as part of a bleeder system under § 75.334 shall be traveled in its entirety. Measurements of methane and oxygen concentrations and air quantities and a test to determine if the air is moving in the proper direction shall be made at the measurement point locations specified in the mine ventilation plan to determine the effectiveness of the bleeder system.\n\n(iv) In lieu of the requirements of paragraphs (a)(2)(i) and (iii) of this section, an alternative method of evaluation may be specified in the ventilation plan provided the alternative method results in proper evaluation of the effectiveness of the bleeder system.\n\n(b) Hazardous conditions and violations of mandatory health or safety standards. At least every 7 days, an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(8) of this section shall be made by a certified person designated by the operator at the following locations:\n\n(1) In at least one entry of each intake air course, in its entirety, so that the entire air course is traveled.\n\n(2) In at least one entry of each return air course, in its entirety, so that the entire air course is traveled.\n\n(3) In each longwall or shortwall travelway in its entirety, so that the entire travelway is traveled.\n\n(4) At each seal along return and bleeder air courses and at each seal along intake air courses not examined under § 75.360(b)(5).\n\n(5) In each escapeway so that the entire escapeway is traveled.\n\n(6) On each working section not examined under § 75.360(b)(3) during the previous 7 days.\n\n(7) At each water pump not examined during a preshift examination conducted during the previous 7 days.\n\n(8) Weekly examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust; and\n\n(iv) § 75.1403—maintenance of off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) Measurements and tests. At least every 7 days, a certified person shall—\n\n(1) Determine the volume of air entering the main intakes and in each intake split;\n\n(2) Determine the volume of air and test for methane in the last open crosscut in any pair or set of developing entries or rooms, in the return of each split of air immediately before it enters the main returns, and where the air leaves the main returns; and\n\n(3) Test for methane in the return entry nearest each set of seals immediately after the air passes the seals.\n\n(d) Hazardous conditions shall be corrected immediately. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Any violation of the nine mandatory health or safety standards found during a weekly examination shall be corrected.\n\n(e) The weekly examination may be conducted at the same time as the preshift or on-shift examinations.\n\n(f) (1) The weekly examination is not required during any 7 day period in which no one enters any underground area of the mine.\n\n(2) Except for certified persons required to make examinations, no one shall enter any underground area of the mine if a weekly examination has not been completed within the previous 7 days.\n\n(g) Certification. The person making the weekly examinations shall certify by initials, date, and the time that the examination was made. Certifications and times shall appear at enough locations to show that the entire area has been examined.\n\n(h) Recordkeeping. At the completion of any shift during which a portion of a weekly examination is conducted, a record of the results of each weekly examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards found during each examination and their locations, the corrective action taken, and the results and location of air and methane measurements, shall be made. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the person making the examination or a person designated by the operator. If made by a person other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(i) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 77 FR 20715, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.380","heading":"Escapeways; bituminous and lignite mines.","id":"75.380","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.380","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Except in situations addressed in § 75.381, § 75.385 and § 75.386, at least two separate and distinct travelable passageways shall be designated as escapeways and shall meet the requirements of this section.\n\n(b) (1) Escapeways shall be provided from each working section, and each area where mechanized mining equipment is being installed or removed, continuous to the surface escape drift opening or continuous to the escape shaft or slope facilities to the surface.\n\n(2) During equipment installation, these escapeways shall begin at the projected location for the section loading point. During equipment removal, they shall begin at the location of the last loading point.\n\n(c) The two separate and distinct escapeways required by this section shall not end at a common shaft, slope, or drift opening, except that multiple compartment shafts or slopes separated by walls constructed of noncombustible material may be used as separate and distinct passageways.\n\n(d) Each escapeway shall be—\n\n(1) Maintained in a safe condition to always assure passage of anyone, including disabled persons;\n\n(2) Clearly marked to show the route and direction of travel to the surface;\n\n(3) Maintained to at least a height of 5 feet from the mine floor to the mine roof, excluding the thickness of any roof support, except that the escapeways shall be maintained to at least the height of the coalbed, excluding the thickness of any roof support, where the coalbed is less than 5 feet. In areas of mines where escapeways pass through doors, the height may be less than 5 feet, provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. In areas of mines developed before November 16, 1992, where escapeways pass over or under overcasts or undercasts, the height may be less than 5 feet provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient height is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(4) Maintained at least 6 feet wide except—\n\n(i) Where necessary supplemental roof support is installed, the escapeway shall not be less than 4 feet wide; or\n\n(ii) Where the route of travel passes through doors or other permanent ventilation controls, the escapeway shall be at least 4 feet wide to enable miners to escape quickly in an emergency, or\n\n(iii) Where the alternate escapeway passes through doors or other permanent ventilation controls or where supplemental roof support is required and sufficient width is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher, or\n\n(iv) Where mobile equipment near working sections, and other equipment essential to the ongoing operation of longwall sections, is necessary during normal mining operations, such as material cars containing rock dust or roof control supplies, or is to be used for the evacuation of miners off the section in the event of an emergency. In any instance, escapeways shall be of sufficient width to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(5) Located to follow the most direct, safe and practical route to the nearest mine opening suitable for the safe evacuation of miners; and\n\n(6) Provided with ladders, stairways, ramps, or similar facilities where the escapeways cross over obstructions.\n\n(7) Provided with a continuous, durable directional lifeline or equivalent device that shall be—\n\n(i) Installed and maintained throughout the entire length of each escapeway as defined in paragraph (b)(1) of this section;\n\n(ii) Flame-resistant in accordance with the requirements of part 18 of this chapter upon replacement of existing lifelines; but in no case later than June 15, 2009;\n\n(iii) Marked with a reflective material every 25 feet;\n\n(iv) Located in such a manner for miners to use effectively to escape;\n\n(v) Equipped with one directional indicator cone securely attached to the lifeline, signifying the route of escape, placed at intervals not exceeding 100 feet. Cones shall be installed so that the tapered section points inby;\n\n(vi) Equipped with one sphere securely attached to the lifeline at each intersection where personnel doors are installed in adjacent crosscuts;\n\n(vii) Equipped with two securely attached cones, installed consecutively with the tapered section pointing inby, to signify an attached branch line is immediately ahead.\n\n(A) A branch line leading from the lifeline to an SCSR cache will be marked with four cones with the base sections in contact to form two diamond shapes. The cones must be placed within reach of the lifeline.\n\n(B) A branch line leading from the lifeline to a refuge alternative will be marked with a rigid spiraled coil at least eight inches in length. The spiraled coil must be placed within reach of the lifeline (see Illustration 1 below).\n\n(e) Surface openings shall be adequately protected to prevent surface fires, fumes, smoke, and flood water from entering the mine.\n\n(f) Primary escapeway. (1) One escapeway that is ventilated with intake air shall be designated as the primary escapeway. The primary escapeway shall have a higher ventilation pressure than the belt entry unless the mine operator submits an alternative in the mine ventilation plan to protect the integrity of the primary escapeway, based on mine specific conditions, which is approved by the district manager.\n\n(2) Paragraphs (f)(3) through (f)(7) of this section apply as follows:\n\n(i) To all areas of a primary escapeway developed on or after November 16, 1992;\n\n(ii) Effective as of June 10, 1997, to all areas of a primary escapeway developed between March 30, 1970 and November 16, 1992; and\n\n(iii) Effective as of June 10, 1997, to all areas of the primary escapeway developed prior to March 30, 1970 where separation of the belt and trolley haulage entries from the primary escapeway existed prior to November 16, 1992.\n\n(3) The following equipment is not permitted in the primary escapeway:\n\n(i) Mobile equipment hauling coal except for hauling coal incidental to cleanup or maintenance of the primary escapeway.\n\n(ii) Compressors, except—\n\n(A) Compressors necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Compressors that are components of equipment such as locomotives and rock dusting machines; and\n\n(C) Compressors of less than five horsepower.\n\n(iii) Underground transformer stations, battery charging stations, substations, and rectifiers except—\n\n(A) Where necessary to maintain the escapeway in safe, travelable condition; and\n\n(B) Battery charging stations and rectifiers and power centers with transformers that are either dry-type or contain nonflammable liquid, provided they are located on or near a working section and are moved as the section advances or retreats.\n\n(iv) Water pumps, except—\n\n(A) Water pumps necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Submersible pumps;\n\n(C) Permissible pumps and associated permissible switchgear;\n\n(D) Pumps located on or near a working section that are moved as the section advances or retreats;\n\n(E) Pumps installed in anthracite mines; and\n\n(F) Small portable pumps.\n\n(4) Mobile equipment operated in the primary escapeway, except for continuous miners and as provided in paragraphs (f)(5), (f)(6), and (f)(7) of this section, shall be equipped with a fire suppression system installed according to §§ 75.1107-3 through 75.1107-16 that is—\n\n(i) Manually operated and attended continuously by a person trained in the systems function and use, or\n\n(ii) A multipurpose dry chemical type capable of both automatic and manual activation.\n\n(5) Personnel carriers and small mobile equipment designed and used only for carrying people and small hand tools may be operated in primary escapeways if—\n\n(i) The equipment is provided with a multipurpose dry chemical type fire suppression system capable of both automatic and manual activation, and the suppression system is suitable for the intended application and is listed or approved by a nationally recognized independent testing laboratory, or,\n\n(ii) Battery powered and provided with two 10 pound multipurpose dry chemical portable fire extinguishers.\n\n(6) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment not provided with a fire suppression system may operate in the primary escapeway if no one is inby except those persons directly engaged in using or moving the equipment.\n\n(7) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment designated and used only as emergency vehicles or ambulances, may be operated in the primary escapeway without fire suppression systems.\n\n(g) Except where separation of belt and trolley haulage entries from designated escapeways did not exist before November 15, 1992, and except as provided in § 75.350(c), the primary escapeway must be separated from belt and trolley haulage entries for its entire length, to and including the first connecting crosscut outby each loading point except when a greater or lesser distance for this separation is specified and approved in the mine ventilation plan and does not pose a hazard to miners.\n\n(h) Alternate escapeway. One escapeway shall be designated as the alternate escapeway. The alternate escapeway shall be separated from the primary escapeway for its entire length, except that the alternate and primary escapeways may be ventilated from a common intake air shaft or slope opening.\n\n(i) Mechanical escape facilities shall be provided and maintained for—\n\n(1) Each shaft that is part of a designated escapeway and is greater than 50 feet in depth; and\n\n(2) Each slope from the coal seam to the surface that is part of a designated escapeway and is inclined more than 9 degrees from the horizontal.\n\n(j) Within 30 minutes after mine personnel on the surface have been notified of an emergency requiring evacuation, mechanical escape facilities provided under paragraph (i) of this section shall be operational at the bottom of shaft and slope openings that are part of escapeways.\n\n(k) Except where automatically activated hoisting equipment is used, the bottom of each shaft or slope opening that is part of a designated escapeway shall be equipped with a means of signaling a surface location where a person is always on duty when anyone is underground. When the signal is activated or the evacuation of persons underground is necessary, the person shall assure that mechanical escape facilities are operational as required by paragraph (j) of this section.\n\n(l)(1) Stairways or mechanical escape facilities shall be installed in shafts that are part of the designated escapeways and that are 50 feet or less in depth, except ladders may be used in shafts that are part of the designated escapeways and that are 5 feet or less in depth.\n\n(2) Stairways shall be constructed of concrete or metal, set on an angle not to exceed 45 degrees from the horizontal, and equipped on the open side with handrails. In addition, landing platforms that are at least 2 feet by 4 feet shall be installed at intervals not to exceed 20 vertical feet on the stairways and equipped on the open side with handrails.\n\n(3) Ladders shall be constructed of metal, anchored securely, and set on an angle not to exceed 60 degrees from the horizontal.\n\n(m) A travelway designed to prevent slippage shall be provided in slope and drift openings that are part of designated escapeways, unless mechanical escape facilities are installed.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 69 FR 17530, Apr. 2, 2004; 71 FR 12269, Mar. 9, 2006; 71 FR 71452, Dec. 8, 2006; 73 FR 80613, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-4","heading":"Automatic fire sensors and manual actuators; installation; minimum requirements.","id":"75.1107-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a)(1) Where fire suppression devices are installed on unattended underground equipment, one or more point-type sensors or equivalent shall be installed for each 50 square feet of top surface area, or fraction thereof, of such equipment, and each sensor shall be designed to activate the first suppression system and disconnect the electrical power source to the equipment protected, and, except where sprinklers are used, there shall be in addition, a manual actuator installed to operate the system. Where sprinklers are used, provision shall be made for manual application of water to the protected equipment in lieu of a manual actuator.\n\n(2) Two or more manual actuators, where practicable, shall be installed, as provided in paragraphs (a)(2) (i) and (ii) of this section, to activate fire suppression devices on attended equipment purchased on or after the effective date of this § 75.1107-4. At least one manual actuator shall be used on equipment purchased prior to the effective date of this § 75.1107-4.\n\n(i) Manual actuators installed on attended equipment regularly operated by a miner, as provided in § 75.1107-1(c)(1) shall be located at different locations on the equipment, and at least one manual actuator shall be located within easy reach of the operator's normal operating position.\n\n(ii) Manual actuators to activate fire suppression devices on attended equipment not regularly operated by a miner, as provided in § 75.1107-1(c)(2), shall be installed at different location, and at least one manual actuator shall be installed so as to be easily reached by the miner at the jobsite or by persons approaching the equipment.\n\n(b) Sensors shall, where practicable, be installed in accordance with the recommendations set forth in National Fire Code No. 72A “Local Protective Signaling Systems” (NFPA No. 72A-1967).\n\n(c) On unattended equipment the fire suppression device shall operate independently of the power to the main motor (or equivalent) so it will remain operative if the circuit breakers (or other protective device) actuates. On attended equipment powered through a trailing cable the fire suppression device shall operate independently of the electrical power provided by the cable.\n\n(d) Point-type sensors (such as thermocouple, bimetallic strip, or rate of temperature rise) located in ventilated passageways shall be installed downwind from the equipment to be protected.\n\n(e) Sensor systems shall include a device or method for determining their operative condition.\n\n[37 FR 15301, July 29, 1972]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1731","heading":"Maintenance of belt conveyors and belt conveyor entries.","id":"75.1731","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1731","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Damaged rollers, or other damaged belt conveyor components, which pose a fire hazard must be immediately repaired or replaced. All other damaged rollers, or other damaged belt conveyor components, must be repaired or replaced.\n\n(b) Conveyor belts must be properly aligned to prevent the moving belt from rubbing against the structure or components.\n\n(c) Materials shall not be allowed in the belt conveyor entry where the material may contribute to a frictional heating hazard.\n\n(d) Splicing of any approved conveyor belt must maintain flame-resistant properties of the belt.\n\n[73 FR 80616, Dec. 31, 2008]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1732","heading":"Proximity detection systems.","id":"75.1732","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1732","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"Operators must install proximity detection systems on certain mobile machines.\n\n(a) Machines covered. Operators must equip continuous mining machines, except full-face continuous mining machines, with proximity detection systems by the following dates. For proximity detection systems with miner-wearable components, the mine operator must provide a miner-wearable component to be worn by each miner on the working section by the following dates.\n\n(1) Continuous mining machines manufactured after March 16, 2015 must meet the requirements in this section no later than November 16, 2015. These machines must meet the requirements in this section when placed in service with a proximity detection system.\n\n(2) Continuous mining machines manufactured and equipped with a proximity detection system on or before March 16, 2015 must meet the requirements in this section no later than September 16, 2016.\n\n(3) Continuous mining machines manufactured and not equipped with a proximity detection system on or before March 16, 2015 must meet the requirements in this section no later than March 16, 2018. These machines must meet the requirements in this section when placed in service with a proximity detection system.\n\n(b) Requirements for a proximity detection system. A proximity detection system includes machine-mounted components and miner-wearable components. The system must:\n\n(1) Cause a machine, which is tramming from place-to-place or repositioning, to stop before contacting a miner except for a miner who is in the on-board operator's compartment;\n\n(2) Provide an audible and visual warning signal on the miner-wearable component and a visual warning signal on the machine that alert miners before the system causes a machine to stop. These warning signals must be distinguishable from other signals;\n\n(3) Provide a visual signal on the machine that indicates the machine-mounted components are functioning properly;\n\n(4) Prevent movement of the machine if any machine-mounted component of the system is not functioning properly. However, a system with any machine-mounted component that is not functioning properly may allow machine movement if it provides an audible or visual warning signal, distinguishable from other signals, during movement. Such movement is permitted only for purposes of relocating the machine from an unsafe location for repair;\n\n(5) Be installed to prevent interference that adversely affects performance of any electrical system; and\n\n(6) Be installed and maintained in proper operating condition by a person trained in the installation and maintenance of the system.\n\n(c) Proximity detection system checks. Operators must:\n\n(1) Designate a person who must perform a check of machine-mounted components of the proximity detection system to verify that components are intact, that the system is functioning properly, and take action to correct defects—\n\n(i) At the beginning of each shift when the machine is to be used; or\n\n(ii) Immediately prior to the time the machine is to be operated if not in use at the beginning of a shift; or\n\n(iii) Within 1 hour of a shift change if the shift change occurs without an interruption in production.\n\n(2) Check for proper operation of miner-wearable components at the beginning of each shift that the components are to be used and correct defects before the components are used.\n\n(d) Certifications and records. The operator must make and retain certifications and records as follows:\n\n(1) At the completion of the check of machine-mounted components required under paragraph (c)(1) of this section, a certified person under § 75.100 must certify by initials, date, and time that the check was conducted. Defects found as a result of the check, including corrective actions and dates of corrective actions, must be recorded before the end of the shift;\n\n(2) Make a record of the defects found as a result of the check of miner-wearable components required under paragraph (c)(2) of this section, including corrective actions and dates of corrective actions;\n\n(3) Make a record of the persons trained in the installation and maintenance of proximity detection systems required under paragraph (b)(6) of this section;\n\n(4) Maintain records in a secure book or electronically in a secure computer system not susceptible to alteration; and\n\n(5) Retain records for at least one year and make them available for inspection by authorized representatives of the Secretary and representatives of miners.\n\n[80 FR 2202, Jan. 15, 2015]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4608787","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}