{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4608753","name":"Whitetail Preparation Facility","status":"Abandoned","status_date":"2017-03-14","mine_type":"Facility","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Preston","nearest_town":"Newberg","operator_id":"0051089","operator_name":"Kingwood Mining Company LLC","controller_id":"0127923","controller_name":"Alpha Natural Resources Holdings, Inc","district":"C03","office":"Morgantown WV Field Office","employees":0,"latitude":39.345556,"longitude":-79.815278},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":2434},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4608753","name":"Whitetail Preparation Facility"},"operator":{"type":"operator","id":"0051089","name":"Kingwood Mining Company LLC"},"controller":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C01883","name":"El Paso Energy Corp"},"object":{"type":"mine","id":"4608753","name":"Whitetail Preparation Facility"},"validFrom":"1979-10-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608753|C01883|1979-10-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24023","name":"Coastal Coal-West Virginia Llc"},"object":{"type":"mine","id":"4608753","name":"Whitetail Preparation Facility"},"validFrom":"1999-01-01","validTo":"2003-01-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608753|P24023|1999-01-01|2003-01-31"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C01883","name":"El Paso Energy Corp"},"object":{"type":"operator","id":"P24023","name":"Coastal Coal-West Virginia Llc"},"validFrom":"1999-01-01","validTo":"2003-01-31","current":false,"derived":true,"evidenceMineId":"4608753","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608753|P24023|1999-01-01|C01883|1979-10-01|56598"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0051089","name":"Kingwood Mining Company LLC"},"object":{"type":"mine","id":"4608753","name":"Whitetail Preparation Facility"},"validFrom":"2003-02-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608753|0051089|2003-02-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"4608753","name":"Whitetail Preparation Facility"},"validFrom":"2003-02-01","validTo":"2016-07-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608753|0041211|2003-02-01|2016-07-25"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"0051089","name":"Kingwood Mining Company LLC"},"validFrom":"2003-02-01","validTo":"2016-07-25","current":false,"derived":true,"evidenceMineId":"4608753","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608753|0051089|2003-02-01|0041211|2003-02-01|1665"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"mine","id":"4608753","name":"Whitetail Preparation Facility"},"validFrom":"2016-07-26","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608753|0127923|2016-07-26|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"operator","id":"0051089","name":"Kingwood Mining Company LLC"},"validFrom":"2016-07-26","validTo":null,"current":true,"derived":true,"evidenceMineId":"4608753","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608753|0051089|2003-02-01|0127923|2016-07-26|25600"}}],"coverage":{"historyRecords":3,"edgeCount":8,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":8,"firstDate":"2000-02-24","lastDate":"2001-10-08","metrics":{"daysLost":289,"injuries":7,"fatalities":0,"recentRows":0,"restrictedDays":14,"contractorRecords":3},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"184511","DOCUMENT_NO":"220012880162","ACCIDENT_DT":"10/08/2001","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Backhoe operator, Trackhoe operator, Crane operator","NO_INJURIES":"1","NARRATIVE":"WHILE USING A UTILITY KNIFE TO CUT A PLASTIC LID FROM A BUCKET, THE KNIFE SLIPPED AND CUT THE EMPLOYEE'S LEFT THUMB.","sourceDate":"2001-10-08"},{"SOURCE_ROW_NUMBER":"42513","DOCUMENT_NO":"220013600165","ACCIDENT_DT":"09/24/2001","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","NARRATIVE":"THE EMPLOYEE WAS SLIDING A PIECE OF WALKWAY IN THE BED OF SHOP TRUCK. THE PIECE OF WALKWAY CAME TO A SUDDEN STOP CAUSING THE EMPLOYEE TO BUMP HIS CHIM ON THE WALKWAY AND CHIP HIS FRONT TOOTH. NOTE: WAS NOT NOTIFIED ABOUT INJURY UNTIL 12/18/01.","sourceDate":"2001-09-24"},{"SOURCE_ROW_NUMBER":"274747","DOCUMENT_NO":"220010510142","ACCIDENT_DT":"02/10/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Contact with hot objects or substances","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"45","NARRATIVE":"MEN WERE WELDING ON THE BIN WHEN AN EXPLOSION OCCURRED DAMAGING THE LOAD OUT SYSTEM.","sourceDate":"2001-02-10"},{"SOURCE_ROW_NUMBER":"128344","DOCUMENT_NO":"220010510001","ACCIDENT_DT":"02/10/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"IGNITION OR EXPLOSION OF GAS OR DUST","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"RUNNING LOADOUT SYSTEM WHILE WELDING. EXPLOSION OCCURRED. EXTENSIVE DAMAGE TO LOAD-OUT SYSTEM AND LOSS OF ONE PRODUCTION SHIFT.","sourceDate":"2001-02-10"},{"SOURCE_ROW_NUMBER":"123977","DOCUMENT_NO":"220010330027","ACCIDENT_DT":"01/22/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Truck driver","NO_INJURIES":"1","DAYS_LOST":"10","NARRATIVE":"THE ROAD WAS SNOW COVERED AND ICY. IT HAD BEEN ASHED RECENTLY. THE DRIVER STARTED DOWN THE HILL TO THE PLANT WHEN IT JUST TOOK OFF AND OVERTURNED. HE WAS CUT ON THE EAR AND HIS SHOULDER WAS BR UISED.","sourceDate":"2001-01-22"},{"SOURCE_ROW_NUMBER":"227554","DOCUMENT_NO":"220001990090","ACCIDENT_DT":"07/05/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Mine manager, Mine foreman, Mine owner","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"SINCE 4/15/00, EMPLOYEE HAD EXPERIENCE SOME PAIN ONCE IN A WHILE IN HIS BACK & RIGHT LEG, BUT ON 7/5/00--WHEN HE CLIMBED INTO HIS TRUCK TO GO HOME--HE FELT SEVERE PAIN IN BACK & RIGHT LEG, SO HE WENT TO THE EMERGENCY ROOM.","sourceDate":"2000-07-05"},{"SOURCE_ROW_NUMBER":"29626","DOCUMENT_NO":"220001470052","ACCIDENT_DT":"05/15/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Mine manager, Mine foreman, Mine owner","NO_INJURIES":"1","DAYS_LOST":"157","NARRATIVE":"EMPLOYEE HAD BEEN LIFTING 5 GAL CONTAINERS WITH ANTIFOAM OVER HIS HEAD INTO A SUMP WHEN HE STRAINED LEFT SIDE, NECK AND SHOULDER AREA.","sourceDate":"2000-05-15"},{"SOURCE_ROW_NUMBER":"154378","DOCUMENT_NO":"220000620010","ACCIDENT_DT":"02/24/2000","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall from scaffolds, walkways, platforms","OCCUPATION":"Mine manager, Mine foreman, Mine owner","NO_INJURIES":"1","DAYS_LOST":"75","NARRATIVE":"THE INJURED PERSON WAS CLIMBING DOWN FROM THE RIGID/STATIONARY SCAFFOLDING, MISTEPPED AND FELL 3-4' TO THE CONCRETE FLOOR, RESULTING INJURY TO HIS LEFT KNEECAP, HAND AND RIGHT ANKLE.","sourceDate":"2000-02-24"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2017-03-14","lastDate":"2017-03-14","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":61,"firstDate":"2000-04-26","lastDate":"2011-04-07","metrics":{"ss":20,"delinquent":59,"recentRows":0,"paidPenalty":6104.08,"proposedPenalty":6652,"currentAssessment":6154},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1704539","VIOLATION_NO":"8025635","ISSUE_DT":"04/07/2011","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-04-07"},{"SOURCE_ROW_NUMBER":"1681189","VIOLATION_NO":"8018910","ISSUE_DT":"10/26/2009","CFR_STANDARD_CD":"77.1710(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"585.00","CURRENT_ASSESSMENT_AMT":"409.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-10-26"},{"SOURCE_ROW_NUMBER":"1681627","VIOLATION_NO":"8017527","ISSUE_DT":"09/28/2009","CFR_STANDARD_CD":"77.215-4","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-09-28"},{"SOURCE_ROW_NUMBER":"1681626","VIOLATION_NO":"8017526","ISSUE_DT":"09/28/2009","CFR_STANDARD_CD":"77.215(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-09-28"},{"SOURCE_ROW_NUMBER":"1681625","VIOLATION_NO":"8017525","ISSUE_DT":"09/28/2009","CFR_STANDARD_CD":"77.215(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-09-28"},{"SOURCE_ROW_NUMBER":"1679663","VIOLATION_NO":"6602839","ISSUE_DT":"10/07/2008","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-10-07"},{"SOURCE_ROW_NUMBER":"1679662","VIOLATION_NO":"6602838","ISSUE_DT":"10/01/2008","CFR_STANDARD_CD":"77.400(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-10-01"},{"SOURCE_ROW_NUMBER":"1672958","VIOLATION_NO":"6602821","ISSUE_DT":"05/28/2008","CFR_STANDARD_CD":"77.410(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-05-28"},{"SOURCE_ROW_NUMBER":"1672961","VIOLATION_NO":"6607204","ISSUE_DT":"05/27/2008","CFR_STANDARD_CD":"77.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"117.00","CURRENT_ASSESSMENT_AMT":"117.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-05-27"},{"SOURCE_ROW_NUMBER":"1672960","VIOLATION_NO":"6607203","ISSUE_DT":"05/27/2008","CFR_STANDARD_CD":"77.1109(c)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-05-27"},{"SOURCE_ROW_NUMBER":"1672959","VIOLATION_NO":"6607202","ISSUE_DT":"05/22/2008","CFR_STANDARD_CD":"77.1109(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-05-22"},{"SOURCE_ROW_NUMBER":"1321942","VIOLATION_NO":"6606803","ISSUE_DT":"02/13/2008","CFR_STANDARD_CD":"77.505","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-02-13"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":5,"firstDate":"2008-02-20","lastDate":"2011-03-18","metrics":{"appeals":0,"decisions":5,"recentRows":0,"decisionPenalty":1048,"originalPenalty":1546},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"50494","VIOLATION_NO":"8018910","DOCKET_NO":"WEVA 2010-481","DECISION_DT":"03/18/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"409.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2011-03-18"},{"SOURCE_ROW_NUMBER":"214233","VIOLATION_NO":"6606802","DOCKET_NO":"WEVA 2008-832","DECISION_DT":"10/14/2009","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"263.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2009-10-14"},{"SOURCE_ROW_NUMBER":"214234","VIOLATION_NO":"6606801","DOCKET_NO":"WEVA 2008-833","DECISION_DT":"04/13/2009","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"176.00","DECISION_PENALTY_AMT":"176.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2009-04-13"},{"SOURCE_ROW_NUMBER":"201212","VIOLATION_NO":"6603094","DOCKET_NO":"WEVA 2007-657","DECISION_DT":"02/20/2008","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"T","JUDGE_LAST_NAME":"Hodgdon","sourceDate":"2008-02-20"},{"SOURCE_ROW_NUMBER":"12411","VIOLATION_NO":"6603093","DOCKET_NO":"WEVA 2007-657","DECISION_DT":"02/20/2008","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"T","JUDGE_LAST_NAME":"Hodgdon","sourceDate":"2008-02-20"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":132,"firstDate":"2000-06-13","lastDate":"2013-12-11","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":5,"validSamples":127,"maxConcentration":4.35,"concentrationTotal":46.631},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"561561","CASS_NUM":"58124787","SMP_TAKEN_DT":"12/11/2013","CONC":"0","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MINE FOREMAN/MINE MANAGER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-12-11"},{"SOURCE_ROW_NUMBER":"1463046","CASS_NUM":"57780275","SMP_TAKEN_DT":"10/23/2008","CONC":".27","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-10-23"},{"SOURCE_ROW_NUMBER":"908299","CASS_NUM":"57780286","SMP_TAKEN_DT":"10/23/2008","CONC":".05","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CLEANING PLANT OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-10-23"},{"SOURCE_ROW_NUMBER":"855012","CASS_NUM":"57780266","SMP_TAKEN_DT":"10/23/2008","CONC":".33","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-10-23"},{"SOURCE_ROW_NUMBER":"282320","CASS_NUM":"57780254","SMP_TAKEN_DT":"10/23/2008","CONC":".028","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-10-23"},{"SOURCE_ROW_NUMBER":"108792","CASS_NUM":"57780293","SMP_TAKEN_DT":"10/23/2008","CONC":".31","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-10-23"},{"SOURCE_ROW_NUMBER":"1597712","CASS_NUM":"57741525","SMP_TAKEN_DT":"5/28/2008","CONC":".163","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-05-28"},{"SOURCE_ROW_NUMBER":"1467957","CASS_NUM":"57741722","SMP_TAKEN_DT":"5/28/2008","CONC":".086","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-05-28"},{"SOURCE_ROW_NUMBER":"1369432","CASS_NUM":"57741739","SMP_TAKEN_DT":"5/28/2008","CONC":".225","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL SAMPLER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-05-28"},{"SOURCE_ROW_NUMBER":"1158764","CASS_NUM":"57741767","SMP_TAKEN_DT":"5/28/2008","CONC":".182","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-05-28"},{"SOURCE_ROW_NUMBER":"1131795","CASS_NUM":"57741813","SMP_TAKEN_DT":"5/28/2008","CONC":".145","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CLEANING PLANT OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-05-28"},{"SOURCE_ROW_NUMBER":"386287","CASS_NUM":"57741766","SMP_TAKEN_DT":"5/28/2008","CONC":".057","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-05-28"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":11,"firstDate":"2000-06-16","lastDate":"2010-03-11","metrics":{"linkedIssuances":11},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":5,"firstDate":"2007-06-04","lastDate":"2009-10-26","metrics":{"decisions":5,"ssChanged":4,"recentRows":0,"decisionPenalty":1048,"proposedPenalty":1546},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"242996","CITATION_NO":"8018910","CITATION_ISSUE_DT":"10/26/2009","DOCKET_NO":"WEVA 2010-481","DECISION_DT":"03/18/2011","CFR_STANDARD_CODE":"77.1710(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"409.00","sourceDate":"2009-10-26"},{"SOURCE_ROW_NUMBER":"174749","CITATION_NO":"6606802","CITATION_ISSUE_DT":"02/13/2008","DOCKET_NO":"WEVA 2008-832","DECISION_DT":"10/14/2009","CFR_STANDARD_CODE":"77.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"263.00","sourceDate":"2008-02-13"},{"SOURCE_ROW_NUMBER":"6874","CITATION_NO":"6606801","CITATION_ISSUE_DT":"02/13/2008","DOCKET_NO":"WEVA 2008-833","DECISION_DT":"04/13/2009","CFR_STANDARD_CODE":"77.502","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"176.00","DECISION_PENALTY_AMT":"176.00","sourceDate":"2008-02-13"},{"SOURCE_ROW_NUMBER":"175774","CITATION_NO":"6603094","CITATION_ISSUE_DT":"06/04/2007","DOCKET_NO":"WEVA 2007-657","DECISION_DT":"02/20/2008","CFR_STANDARD_CODE":"77.505","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2007-06-04"},{"SOURCE_ROW_NUMBER":"6326","CITATION_NO":"6603093","CITATION_ISSUE_DT":"06/04/2007","DOCKET_NO":"WEVA 2007-657","DECISION_DT":"02/20/2008","CFR_STANDARD_CODE":"77.400(a)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2007-06-04"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":1588,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":15,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":297,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":13,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"1999-01-01","lastDate":"2003-02-01","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":61,"firstDate":"2000-04-20","lastDate":"2017-02-14","metrics":{"inspectors":82,"recentRows":0,"onSiteHours":1046,"inspectionHours":1818.25,"inspectionSamples":55},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"679917","EVENT_NO":"6275396","INSPECTION_BEGIN_DT":"02/14/2017","INSPECTION_END_DT":"02/14/2017","ACTIVITY_CODE":"E24","ACTIVITY":"Other Technical Compliance Investigations","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2017-02-14"},{"SOURCE_ROW_NUMBER":"736997","EVENT_NO":"6273954","INSPECTION_BEGIN_DT":"10/03/2016","INSPECTION_END_DT":"10/05/2016","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.5","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2016-10-03"},{"SOURCE_ROW_NUMBER":"1057226","EVENT_NO":"6273941","INSPECTION_BEGIN_DT":"04/04/2016","INSPECTION_END_DT":"06/02/2016","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2016-04-04"},{"SOURCE_ROW_NUMBER":"450736","EVENT_NO":"6273808","INSPECTION_BEGIN_DT":"10/01/2015","INSPECTION_END_DT":"10/07/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.5","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2015-10-01"},{"SOURCE_ROW_NUMBER":"682531","EVENT_NO":"6264227","INSPECTION_BEGIN_DT":"04/01/2015","INSPECTION_END_DT":"07/01/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13.5","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2015-04-01"},{"SOURCE_ROW_NUMBER":"1052309","EVENT_NO":"6264074","INSPECTION_BEGIN_DT":"11/13/2014","INSPECTION_END_DT":"11/13/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2014-11-13"},{"SOURCE_ROW_NUMBER":"224928","EVENT_NO":"6263919","INSPECTION_BEGIN_DT":"04/01/2014","INSPECTION_END_DT":"04/02/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2014-04-01"},{"SOURCE_ROW_NUMBER":"447254","EVENT_NO":"6263910","INSPECTION_BEGIN_DT":"12/10/2013","INSPECTION_END_DT":"12/11/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"9.25","sourceDate":"2013-12-10"},{"SOURCE_ROW_NUMBER":"807362","EVENT_NO":"6263816","INSPECTION_BEGIN_DT":"09/25/2013","INSPECTION_END_DT":"09/25/2013","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.5","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2013-09-25"},{"SOURCE_ROW_NUMBER":"145337","EVENT_NO":"6263804","INSPECTION_BEGIN_DT":"05/02/2013","INSPECTION_END_DT":"05/06/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13.5","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2013-05-02"},{"SOURCE_ROW_NUMBER":"252434","EVENT_NO":"6263637","INSPECTION_BEGIN_DT":"02/04/2013","INSPECTION_END_DT":"02/06/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2013-02-04"},{"SOURCE_ROW_NUMBER":"269777","EVENT_NO":"6263393","INSPECTION_BEGIN_DT":"06/06/2012","INSPECTION_END_DT":"06/06/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"19","SUM_TOTAL_ON_SITE_HOURS":"14","sourceDate":"2012-06-06"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":122,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017-Q1":{"hours":520,"employees":1,"production":0},"2016-Q4":{"hours":448,"employees":1,"production":0},"2016-Q3":{"hours":488,"employees":1,"production":0},"2016-Q2":{"hours":512,"employees":1,"production":0},"2016-Q1":{"hours":488,"employees":1,"production":0},"2015-Q4":{"hours":960,"employees":2,"production":0},"2015-Q3":{"hours":984,"employees":2,"production":0},"2015-Q2":{"hours":968,"employees":2,"production":0},"2015-Q1":{"hours":1008,"employees":2,"production":0},"2014-Q4":{"hours":856,"employees":2,"production":0},"2014-Q3":{"hours":992,"employees":2,"production":0},"2014-Q2":{"hours":960,"employees":2,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":29,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2008":{"hours":91987,"employees":47,"production":0},"2009":{"hours":32529,"employees":16,"production":0},"2010":{"hours":5912,"employees":4,"production":0},"2011":{"hours":4640,"employees":3,"production":0},"2012":{"hours":2888,"employees":2,"production":0},"2013":{"hours":3896,"employees":2,"production":0},"2014":{"hours":3784,"employees":2,"production":0},"2015":{"hours":3920,"employees":2,"production":0},"2016":{"hours":1936,"employees":1,"production":0},"2017":{"hours":520,"employees":1,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":40,"firstDate":"2001-12-17","lastDate":"2008-10-21","metrics":{"recentRows":0,"doseOver100":2,"actDoseTotal":1935,"pelDoseTotal":1241},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"242217","EVENT_NO":"6255103","SURVEY_DATE":"10/21/2008","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"81","PEL_DOSE_90":"30","SURVEY_TYPE":"I","sourceDate":"2008-10-21"},{"SOURCE_ROW_NUMBER":"242216","EVENT_NO":"6255103","SURVEY_DATE":"10/21/2008","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"6","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2008-10-21"},{"SOURCE_ROW_NUMBER":"242215","EVENT_NO":"6255103","SURVEY_DATE":"10/21/2008","OCCUPATION_CD_DESC":"FROTH CELL OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"60","PEL_DOSE_90":"46","SURVEY_TYPE":"I","sourceDate":"2008-10-21"},{"SOURCE_ROW_NUMBER":"242214","EVENT_NO":"6255103","SURVEY_DATE":"10/21/2008","OCCUPATION_CD_DESC":"CLEANING PLANT OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"50","PEL_DOSE_90":"35","SURVEY_TYPE":"I","sourceDate":"2008-10-21"},{"SOURCE_ROW_NUMBER":"242213","EVENT_NO":"6255103","SURVEY_DATE":"10/21/2008","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"120","PEL_DOSE_90":"113","SURVEY_TYPE":"I","sourceDate":"2008-10-21"},{"SOURCE_ROW_NUMBER":"242208","EVENT_NO":"6254001","SURVEY_DATE":"06/06/2008","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"10","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2008-06-06"},{"SOURCE_ROW_NUMBER":"242212","EVENT_NO":"6254001","SURVEY_DATE":"06/04/2008","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"29","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2008-06-04"},{"SOURCE_ROW_NUMBER":"242211","EVENT_NO":"6254001","SURVEY_DATE":"06/04/2008","OCCUPATION_CD_DESC":"CLEANING PLANT OPERATOR","ACT_DOSE_85":"38","PEL_DOSE_90":"28","SURVEY_TYPE":"I","sourceDate":"2008-06-04"},{"SOURCE_ROW_NUMBER":"242210","EVENT_NO":"6254001","SURVEY_DATE":"06/04/2008","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","ACT_DOSE_85":"52","PEL_DOSE_90":"33","SURVEY_TYPE":"I","sourceDate":"2008-06-04"},{"SOURCE_ROW_NUMBER":"242209","EVENT_NO":"6254001","SURVEY_DATE":"06/04/2008","OCCUPATION_CD_DESC":"UTILITY MAN","ACT_DOSE_85":"56","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2008-06-04"},{"SOURCE_ROW_NUMBER":"242202","EVENT_NO":"4351801","SURVEY_DATE":"02/13/2008","OCCUPATION_CD_DESC":"CLEANING PLANT OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"76","PEL_DOSE_90":"58","SURVEY_TYPE":"I","sourceDate":"2008-02-13"},{"SOURCE_ROW_NUMBER":"242201","EVENT_NO":"4351801","SURVEY_DATE":"02/13/2008","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"63","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2008-02-13"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":1,"firstDate":"2002-03-26","lastDate":"2002-03-26","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":0,"validSamples":1,"quartzPctTotal":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"26280","CASSETTE_NO":"57406204","SAMPLE_DT":"03/26/2002","OCC_CODE_DESC":"MECHANIC","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-03-26"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":69,"firstDate":"2000-04-26","lastDate":"2011-04-07","metrics":{"ss":26,"amountDue":6154,"contested":5,"amountPaid":6104.08,"recentRows":0,"section104d":1,"unterminated":0,"proposedPenalty":6652},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2769795","VIOLATION_NO":"8025635","VIOLATION_ISSUE_DT":"04/07/2011","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/07/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-04-07"},{"SOURCE_ROW_NUMBER":"2769840","VIOLATION_NO":"8018910","VIOLATION_ISSUE_DT":"10/26/2009","SIG_SUB":"Y","PART_SECTION":"77.1710(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Highly","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/26/2009","PROPOSED_PENALTY":"585","AMOUNT_DUE":"409","AMOUNT_PAID":"409","CONTESTED_IND":"Y","DOCKET_NO":"WEVA 2010-481","sourceDate":"2009-10-26"},{"SOURCE_ROW_NUMBER":"2769837","VIOLATION_NO":"8017527","VIOLATION_ISSUE_DT":"09/28/2009","SIG_SUB":"N","PART_SECTION":"77.215-4","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/29/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-09-28"},{"SOURCE_ROW_NUMBER":"2769836","VIOLATION_NO":"8017526","VIOLATION_ISSUE_DT":"09/28/2009","SIG_SUB":"N","PART_SECTION":"77.215(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/14/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-09-28"},{"SOURCE_ROW_NUMBER":"2769835","VIOLATION_NO":"8017525","VIOLATION_ISSUE_DT":"09/28/2009","SIG_SUB":"N","PART_SECTION":"77.215(h)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/14/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-09-28"},{"SOURCE_ROW_NUMBER":"2769839","VIOLATION_NO":"6602839","VIOLATION_ISSUE_DT":"10/07/2008","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/08/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-10-07"},{"SOURCE_ROW_NUMBER":"2769838","VIOLATION_NO":"6602838","VIOLATION_ISSUE_DT":"10/01/2008","SIG_SUB":"N","PART_SECTION":"77.400(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/02/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-10-01"},{"SOURCE_ROW_NUMBER":"2769822","VIOLATION_NO":"6602821","VIOLATION_ISSUE_DT":"05/28/2008","SIG_SUB":"N","PART_SECTION":"77.410(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/28/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-05-28"},{"SOURCE_ROW_NUMBER":"2769825","VIOLATION_NO":"6607204","VIOLATION_ISSUE_DT":"05/27/2008","SIG_SUB":"N","PART_SECTION":"77.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/28/2008","PROPOSED_PENALTY":"117","AMOUNT_DUE":"117","AMOUNT_PAID":"117","CONTESTED_IND":"N","sourceDate":"2008-05-27"},{"SOURCE_ROW_NUMBER":"2769824","VIOLATION_NO":"6607203","VIOLATION_ISSUE_DT":"05/27/2008","SIG_SUB":"N","PART_SECTION":"77.1109(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/27/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-05-27"},{"SOURCE_ROW_NUMBER":"2769823","VIOLATION_NO":"6607202","VIOLATION_ISSUE_DT":"05/22/2008","SIG_SUB":"N","PART_SECTION":"77.1109(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/27/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-05-22"},{"SOURCE_ROW_NUMBER":"2769793","VIOLATION_NO":"6606803","VIOLATION_ISSUE_DT":"02/13/2008","SIG_SUB":"N","PART_SECTION":"77.505","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/13/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-02-13"}]}],"safety":{"href":"/api/v1/mines/4608753/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4608753/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":1},{"chapter":"I","heading":"Protective clothing; requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-R/section-77.1710","part":"77","subchapter":"O","subpart":"R","id":"77.1710","citation":"30 CFR 77.1710","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Refuse piles; abandonment.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.215-4","part":"77","subchapter":"O","subpart":"C","id":"77.215-4","citation":"30 CFR 77.215-4","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Refuse piles; construction requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.215","part":"77","subchapter":"O","subpart":"C","id":"77.215","citation":"30 CFR 77.215","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.400","heading":"Mechanical equipment guards.","id":"77.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.400","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings; shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Overhead belts shall be guarded if the whipping action from a broken line would be hazardous to persons below.\n\n(c) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(d) Except when testing the machinery, guards shall be securely in place while machinery is being operated.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.505","heading":"Cable fittings; suitability.","id":"77.505","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.505","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Cables shall enter metal frames of motors, splice boxes, and electric compartments only through proper fittings. When insulated wires, other than cables, pass through metal frames, the holes shall be substantially bushed with insulated bushings.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4608753","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}