{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4608744","name":"Berry Branch Mine","status":"Abandoned and Sealed","status_date":"2002-12-12","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Lincoln","nearest_town":"Spurlockville","operator_id":"P06873","operator_name":"Hobet Mining, Inc.","controller_id":"","controller_name":"","district":"C04","office":"Madison WV Field Office","employees":0,"latitude":38.093888,"longitude":-81.967777},"coverage":{"contributingSources":14,"registeredSources":20,"sourceRows":1178},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4608744","name":"Berry Branch Mine"},"operator":{"type":"operator","id":"P06873","name":"Hobet Mining, Inc."},"controller":{"type":"controller","id":"","name":""},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00012","name":"Ashland Inc et al"},"object":{"type":"mine","id":"4608744","name":"Berry Branch Mine"},"validFrom":"1977-05-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608744|C00012|1977-05-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15759","name":"Clarence R  Peters et al"},"object":{"type":"mine","id":"4608744","name":"Berry Branch Mine"},"validFrom":"1998-09-15","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608744|C15759|1998-09-15|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24032","name":"Laurel Coal Corp"},"object":{"type":"mine","id":"4608744","name":"Berry Branch Mine"},"validFrom":"1998-11-01","validTo":"2002-04-15","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608744|P24032|1998-11-01|2002-04-15"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15759","name":"Clarence R  Peters et al"},"object":{"type":"operator","id":"P24032","name":"Laurel Coal Corp"},"validFrom":"1998-11-01","validTo":"2002-04-15","current":false,"derived":true,"evidenceMineId":"4608744","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608744|P24032|1998-11-01|C15759|1998-09-15|96701"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15759","name":"Richard N  Nester et al"},"object":{"type":"operator","id":"P24032","name":"Laurel Coal Corp"},"validFrom":"1998-11-01","validTo":"2002-04-15","current":false,"derived":true,"evidenceMineId":"4608744","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608744|P24032|1998-11-01|C15759|1998-09-15|96702"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0050432","name":"CMP Mining, LLC"},"object":{"type":"mine","id":"4608744","name":"Berry Branch Mine"},"validFrom":"2002-04-16","validTo":"2002-10-15","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608744|0050432|2002-04-16|2002-10-15"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0040814","name":"Ronnie G  Cornett et al"},"object":{"type":"mine","id":"4608744","name":"Berry Branch Mine"},"validFrom":"2002-04-16","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608744|0040814|2002-04-16|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0040814","name":"Ronnie G  Cornett et al"},"object":{"type":"operator","id":"0050432","name":"CMP Mining, LLC"},"validFrom":"2002-04-16","validTo":"2002-10-15","current":false,"derived":true,"evidenceMineId":"4608744","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608744|0050432|2002-04-16|0040814|2002-04-16|712"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P06873","name":"Hobet Mining, Inc."},"object":{"type":"mine","id":"4608744","name":"Berry Branch Mine"},"validFrom":"2002-10-16","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608744|P06873|2002-10-16|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00012","name":"Ashland Inc et al"},"object":{"type":"operator","id":"P06873","name":"Hobet Mining, Inc."},"validFrom":"2002-10-16","validTo":null,"current":true,"derived":true,"evidenceMineId":"4608744","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608744|P06873|2002-10-16|C00012|1977-05-01|43277"}}],"coverage":{"historyRecords":4,"edgeCount":10,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":17,"firstDate":"2000-02-11","lastDate":"2002-07-03","metrics":{"daysLost":482,"injuries":9,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"132669","DOCUMENT_NO":"220022170115","ACCIDENT_DT":"07/03/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"54","NARRATIVE":"EE WAS OPERATING A S-CAR HAULING COAL. HE RAN IN A HOLE IN THE MINER FLOOR WHICH CAUSED THE SEAT BACK TO HIT HIM IN THE LOWER BACK. HE WORKED UNTIL 7-33-02. HE WENT TO THE DR. AND BEGAN MISSIN G WORK ON 7-23-02. THE REPORT WAS FILED LATE DUE TO THE REASONS I HAVE NOTED.","sourceDate":"2002-07-03"},{"SOURCE_ROW_NUMBER":"21049","DOCUMENT_NO":"220012970020","ACCIDENT_DT":"10/15/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Roof bolter helper, Rock bolter helper, Pinner helper","NO_INJURIES":"1","DAYS_LOST":"35","NARRATIVE":"TRYING TO TURN ALONGSIDE BOLTER & RIB TO PUT UP BOLT S","sourceDate":"2001-10-15"},{"SOURCE_ROW_NUMBER":"68266","DOCUMENT_NO":"220012320098","ACCIDENT_DT":"08/06/2001","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Mine manager, Mine foreman, Mine owner","NO_INJURIES":"1","NARRATIVE":"TWO EMPLOYEES WERE LOADING BELT STRUCTURE TAKEN OUT AFTER A BELT PULL BACK. CO-WORKER WAS OPERATING SCOOP. HE PULLED SCOOP UP TO PILE OF STRUCTURE. EE STARTED LOADING WHILE CO-WORKER WAS GETTI NG OUT OF SCOOP. IN THE ACT OF GETTING OUT OF SCOOP HE ACCIDENTLY HIT LEVER IN SCOOP WHICH LET BUCKET DOWN ON INJURED'S FOOT.","sourceDate":"2001-08-06"},{"SOURCE_ROW_NUMBER":"55394","DOCUMENT_NO":"220012040019","ACCIDENT_DT":"07/14/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"FALL OF ROOF APP 2000 FT FROM WORKING SECTION FALL AREA HAS BEEN CRIBED AND TIMBERED FALL IS IN #3 ENTRY ALONG #4 BELT LIE 70 FT INBY SPAD #447 FALL IS APP 35 FT LONG 14 FT WIDE 4 FT THICK MSH A INSPECTOR EE WAS NOTIFIED AT 1:40 PM 7-14-01.","sourceDate":"2001-07-14"},{"SOURCE_ROW_NUMBER":"98287","DOCUMENT_NO":"220011070009","ACCIDENT_DT":"04/08/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"WHILE FIREBOSSING ROADWAY, FOUND FLL ON #4 BELT,#3 ENTRY INTERSECTION. S;AD #509 ON BELT TO THE LEFT FALL HALFWAY IN BREAK TO #3 ENTRY INTERSECITON. RETURN STOPPING WAS NOT KNOCKED OUT. CRIBS WERE ALREADY LET IN THIS AREA.","sourceDate":"2001-04-08"},{"SOURCE_ROW_NUMBER":"81262","DOCUMENT_NO":"220011020031","ACCIDENT_DT":"03/30/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"314","NARRATIVE":"LIFTING OXYGEN TANKS OFF SUPPLY CAR.","sourceDate":"2001-03-30"},{"SOURCE_ROW_NUMBER":"210294","DOCUMENT_NO":"220003250083","ACCIDENT_DT":"10/28/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"10","NARRATIVE":"LIFTING ROB RAIL ON MINER. SAID HE HURT BACK.","sourceDate":"2000-10-28"},{"SOURCE_ROW_NUMBER":"227545","DOCUMENT_NO":"220002840246","ACCIDENT_DT":"09/29/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"42","NARRATIVE":"LIFTING MINER CABLE TO HANG, PULLED BACK MUSCLE.","sourceDate":"2000-09-29"},{"SOURCE_ROW_NUMBER":"132670","DOCUMENT_NO":"220002510017","ACCIDENT_DT":"08/29/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Mine manager, Mine foreman, Mine owner","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"EMPLOYEE WAS WORKING ON RMOVING A SET OF SCOOP BATTERIES WITH A LIFTING JACK. BATTERIES WERE STUCK IN TRAY. JACK FELL OFF OF SCOOP AND MASHED HIS FINGER AGAINST A CRIB BLOCK.","sourceDate":"2000-08-29"},{"SOURCE_ROW_NUMBER":"274734","DOCUMENT_NO":"220002270267","ACCIDENT_DT":"07/31/2000","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"DURING REGULAR WEEKLY EXAMINATION OF AIRWAYS A ROOF FALL WAS DISCOVERED ON 7-31-00 AT APPROX 8:00 AM THE FALL IS LOCATED IN #7 ENTRY OF #4 MAINS BEGINNING 1 BREAK INBY SPAD 502 & EXTENDEDING T O NEXT INTERSECTION INBY SPAD 502 & EXTENDING TO NEXT INTERSECTION INBY IN #7 ENTRY. APPROX 90'LX20'WX AND RANGING FROM 5' TO 8' T, 8 CRIBS & 8' INBERS WERE ALREADY PRESENT AREA WAS KNOWN TO","sourceDate":"2000-07-31"},{"SOURCE_ROW_NUMBER":"55393","DOCUMENT_NO":"220002200046","ACCIDENT_DT":"07/31/2000","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"DURING REGULAR WEEKLY EXAMINATION OF AIRWAYS A ROOF FALL WAS DISCOVERED ON 7/31/00 AT APPROX 8:00 AM. THE FALL IS LOCATED IN #7 ENTRY OF #4 MAINS BEGINNING 1 BREAK IN BY SPAD 502 AND EXTENDING TO NEXT INTERSECTION IN BY #7 ENTRY. APPROX 90'LONG, 20' WIDE AND RANGING FROM 5-8' THICK. 8 CRIBS AND 8 TIMBERS WERE ALREADY PRESENT. ALL ACCESS TO FALL HAS BEEN CRIBBED OFF.","sourceDate":"2000-07-31"},{"SOURCE_ROW_NUMBER":"218944","DOCUMENT_NO":"220002200047","ACCIDENT_DT":"07/26/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"PULLING BELT BACK TOGETHER WHEN BAR SLIPPED HITTING VICTIM IN LEFT ARM. CAUSING A CUT AND BRUISE OF THE ARM.","sourceDate":"2000-07-26"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2002-12-12","lastDate":"2002-12-12","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":153,"firstDate":"2000-01-18","lastDate":"2002-09-23","metrics":{"ss":90,"delinquent":153,"recentRows":0,"paidPenalty":16458,"proposedPenalty":19596,"currentAssessment":19596},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"780190","VIOLATION_NO":"7215497","ISSUE_DT":"09/23/2002","CFR_STANDARD_CD":"75.701","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"104.00","CURRENT_ASSESSMENT_AMT":"104.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-09-23"},{"SOURCE_ROW_NUMBER":"780189","VIOLATION_NO":"3567966","ISSUE_DT":"09/23/2002","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"83.00","CURRENT_ASSESSMENT_AMT":"83.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-09-23"},{"SOURCE_ROW_NUMBER":"780188","VIOLATION_NO":"3567965","ISSUE_DT":"09/23/2002","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"83.00","CURRENT_ASSESSMENT_AMT":"83.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-09-23"},{"SOURCE_ROW_NUMBER":"780429","VIOLATION_NO":"3568577","ISSUE_DT":"08/20/2002","CFR_STANDARD_CD":"75.333(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"140.00","CURRENT_ASSESSMENT_AMT":"140.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-08-20"},{"SOURCE_ROW_NUMBER":"780428","VIOLATION_NO":"3568576","ISSUE_DT":"08/20/2002","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"104.00","CURRENT_ASSESSMENT_AMT":"104.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-08-20"},{"SOURCE_ROW_NUMBER":"780427","VIOLATION_NO":"3568575","ISSUE_DT":"08/20/2002","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"97.00","CURRENT_ASSESSMENT_AMT":"97.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-08-20"},{"SOURCE_ROW_NUMBER":"780425","VIOLATION_NO":"3568573","ISSUE_DT":"06/24/2002","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"161.00","CURRENT_ASSESSMENT_AMT":"161.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-06-24"},{"SOURCE_ROW_NUMBER":"780166","VIOLATION_NO":"3567920","ISSUE_DT":"06/07/2002","CFR_STANDARD_CD":"75.340(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-06-07"},{"SOURCE_ROW_NUMBER":"780165","VIOLATION_NO":"3567919","ISSUE_DT":"06/07/2002","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-06-07"},{"SOURCE_ROW_NUMBER":"780164","VIOLATION_NO":"3567918","ISSUE_DT":"06/07/2002","CFR_STANDARD_CD":"75.1107-4(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-06-07"},{"SOURCE_ROW_NUMBER":"780163","VIOLATION_NO":"3567916","ISSUE_DT":"06/05/2002","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"122.00","CURRENT_ASSESSMENT_AMT":"122.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-06-05"},{"SOURCE_ROW_NUMBER":"780162","VIOLATION_NO":"3567915","ISSUE_DT":"06/05/2002","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-06-05"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":185,"firstDate":"2000-01-18","lastDate":"2002-08-28","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":20,"validSamples":165,"maxConcentration":6.424,"concentrationTotal":113.987},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"987155","CASS_NUM":"50638195","SMP_TAKEN_DT":"8/28/2002","CONC":".429","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-28"},{"SOURCE_ROW_NUMBER":"746048","CASS_NUM":"50638204","SMP_TAKEN_DT":"8/27/2002","CONC":".087","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-27"},{"SOURCE_ROW_NUMBER":"1188642","CASS_NUM":"50638160","SMP_TAKEN_DT":"8/26/2002","CONC":".284","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-26"},{"SOURCE_ROW_NUMBER":"1238287","CASS_NUM":"50638190","SMP_TAKEN_DT":"8/22/2002","CONC":".07","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-22"},{"SOURCE_ROW_NUMBER":"144419","CASS_NUM":"50638219","SMP_TAKEN_DT":"8/22/2002","CONC":".132","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-22"},{"SOURCE_ROW_NUMBER":"1520840","CASS_NUM":"50638196","SMP_TAKEN_DT":"8/21/2002","CONC":".552","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-21"},{"SOURCE_ROW_NUMBER":"1653724","CASS_NUM":"57406991","SMP_TAKEN_DT":"7/8/2002","CONC":".237","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-07-08"},{"SOURCE_ROW_NUMBER":"1631031","CASS_NUM":"57406987","SMP_TAKEN_DT":"7/8/2002","CONC":".162","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-07-08"},{"SOURCE_ROW_NUMBER":"1408426","CASS_NUM":"57406992","SMP_TAKEN_DT":"7/8/2002","CONC":".42","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-07-08"},{"SOURCE_ROW_NUMBER":"1299077","CASS_NUM":"57406995","SMP_TAKEN_DT":"7/8/2002","CONC":".538","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER HELPER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-07-08"},{"SOURCE_ROW_NUMBER":"853078","CASS_NUM":"57407002","SMP_TAKEN_DT":"7/8/2002","CONC":".25","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-07-08"},{"SOURCE_ROW_NUMBER":"532807","CASS_NUM":"57407004","SMP_TAKEN_DT":"7/8/2002","CONC":".204","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-07-08"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":456,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":89,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":4,"firstDate":"1998-11-01","lastDate":"2002-10-16","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":3},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":40,"firstDate":"2000-01-18","lastDate":"2002-12-13","metrics":{"inspectors":59,"recentRows":0,"onSiteHours":713.5,"inspectionHours":1067,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"966000","EVENT_NO":"4101316","INSPECTION_BEGIN_DT":"12/13/2002","INSPECTION_END_DT":"12/13/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2002-12-13"},{"SOURCE_ROW_NUMBER":"898546","EVENT_NO":"4101308","INSPECTION_BEGIN_DT":"09/30/2002","INSPECTION_END_DT":"10/07/2002","ACTIVITY_CODE":"CDB","ACTIVITY":"ACCIDENT PREVENTION SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2002-09-30"},{"SOURCE_ROW_NUMBER":"376937","EVENT_NO":"4098944","INSPECTION_BEGIN_DT":"08/20/2002","INSPECTION_END_DT":"08/21/2002","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2002-08-20"},{"SOURCE_ROW_NUMBER":"624565","EVENT_NO":"4097082","INSPECTION_BEGIN_DT":"07/09/2002","INSPECTION_END_DT":"07/09/2002","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2002-07-09"},{"SOURCE_ROW_NUMBER":"896324","EVENT_NO":"4098866","INSPECTION_BEGIN_DT":"07/02/2002","INSPECTION_END_DT":"09/26/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"6","SUM_TOTAL_INSP_HOURS":"61.5","SUM_TOTAL_ON_SITE_HOURS":"36.5","sourceDate":"2002-07-02"},{"SOURCE_ROW_NUMBER":"1117857","EVENT_NO":"4098934","INSPECTION_BEGIN_DT":"06/24/2002","INSPECTION_END_DT":"06/24/2002","ACTIVITY_CODE":"CDA","ACTIVITY":"ROOF CONTROL SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2002-06-24"},{"SOURCE_ROW_NUMBER":"1120672","EVENT_NO":"4097128","INSPECTION_BEGIN_DT":"06/04/2002","INSPECTION_END_DT":"06/04/2002","ACTIVITY_CODE":"CEF","ACTIVITY":"OTHER TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2002-06-04"},{"SOURCE_ROW_NUMBER":"730973","EVENT_NO":"4098860","INSPECTION_BEGIN_DT":"05/02/2002","INSPECTION_END_DT":"06/25/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"105.5","SUM_TOTAL_ON_SITE_HOURS":"64","sourceDate":"2002-05-02"},{"SOURCE_ROW_NUMBER":"373572","EVENT_NO":"4092542","INSPECTION_BEGIN_DT":"01/03/2002","INSPECTION_END_DT":"02/07/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2002-01-03"},{"SOURCE_ROW_NUMBER":"236859","EVENT_NO":"4092543","INSPECTION_BEGIN_DT":"01/03/2002","INSPECTION_END_DT":"02/07/2002","ACTIVITY_CODE":"CDB","ACTIVITY":"ACCIDENT PREVENTION SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2002-01-03"},{"SOURCE_ROW_NUMBER":"971913","EVENT_NO":"4094400","INSPECTION_BEGIN_DT":"12/04/2001","INSPECTION_END_DT":"12/04/2001","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2001-12-04"},{"SOURCE_ROW_NUMBER":"955841","EVENT_NO":"4092528","INSPECTION_BEGIN_DT":"10/09/2001","INSPECTION_END_DT":"12/13/2001","ACTIVITY_CODE":"CDB","ACTIVITY":"ACCIDENT PREVENTION SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2001-10-09"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":34,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002-Q4":{"hours":0,"employees":0,"production":0},"2002-Q3":{"hours":1245,"employees":3,"production":37179},"2002-Q2":{"hours":1578,"employees":4,"production":34179},"2002-Q1":{"hours":5179,"employees":35,"production":37109},"2001-Q4":{"hours":16726,"employees":35,"production":73805},"2001-Q3":{"hours":18576,"employees":35,"production":85233},"2001-Q2":{"hours":19643,"employees":35,"production":90113},"2001-Q1":{"hours":19360,"employees":37,"production":111107},"2000-Q4":{"hours":18617,"employees":36,"production":109804},"2000-Q3":{"hours":16821,"employees":34,"production":109636},"2000-Q2":{"hours":18056,"employees":32,"production":107684},"2000-Q1":{"hours":17805,"employees":36,"production":101867}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":9,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":71299,"employees":35,"production":428991},"2001":{"hours":74305,"employees":36,"production":360258},"2002":{"hours":8002,"employees":17,"production":108467}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":10,"firstDate":"2000-03-29","lastDate":"2001-04-12","metrics":{"recentRows":0,"doseOver100":9,"actDoseTotal":29710,"pelDoseTotal":19786},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"241839","EVENT_NO":"4092270","SURVEY_DATE":"04/12/2001","OCCUPATION_CD_DESC":"CONTINUOUS MINER HELPER","MACHINE_CD":"41","MANUFACTURER_CD":"058","ACT_DOSE_85":"7578","PEL_DOSE_90":"5688","SURVEY_TYPE":"I","sourceDate":"2001-04-12"},{"SOURCE_ROW_NUMBER":"241838","EVENT_NO":"4092270","SURVEY_DATE":"04/12/2001","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"41","MANUFACTURER_CD":"120","ACT_DOSE_85":"3296","PEL_DOSE_90":"1339","SURVEY_TYPE":"I","sourceDate":"2001-04-12"},{"SOURCE_ROW_NUMBER":"241837","EVENT_NO":"4092270","SURVEY_DATE":"04/12/2001","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"8196","PEL_DOSE_90":"5024","SURVEY_TYPE":"I","sourceDate":"2001-04-12"},{"SOURCE_ROW_NUMBER":"241836","EVENT_NO":"4092270","SURVEY_DATE":"04/12/2001","OCCUPATION_CD_DESC":"ROOF BOLTER (MOUNTED) (RETURN SIDE)","MACHINE_CD":"31","MANUFACTURER_CD":"058","ACT_DOSE_85":"2698","PEL_DOSE_90":"1492","SURVEY_TYPE":"I","sourceDate":"2001-04-12"},{"SOURCE_ROW_NUMBER":"241835","EVENT_NO":"4092270","SURVEY_DATE":"04/12/2001","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"41","MANUFACTURER_CD":"058","ACT_DOSE_85":"7388","PEL_DOSE_90":"5791","SURVEY_TYPE":"I","sourceDate":"2001-04-12"},{"SOURCE_ROW_NUMBER":"241834","EVENT_NO":"4088627","SURVEY_DATE":"03/29/2000","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"119","PEL_DOSE_90":"98","SURVEY_TYPE":"I","sourceDate":"2000-03-29"},{"SOURCE_ROW_NUMBER":"241833","EVENT_NO":"4088627","SURVEY_DATE":"03/29/2000","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"102","PEL_DOSE_90":"78","SURVEY_TYPE":"I","sourceDate":"2000-03-29"},{"SOURCE_ROW_NUMBER":"241832","EVENT_NO":"4088627","SURVEY_DATE":"03/29/2000","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"40","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2000-03-29"},{"SOURCE_ROW_NUMBER":"241831","EVENT_NO":"4088627","SURVEY_DATE":"03/29/2000","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"171","PEL_DOSE_90":"160","SURVEY_TYPE":"I","sourceDate":"2000-03-29"},{"SOURCE_ROW_NUMBER":"241830","EVENT_NO":"4088627","SURVEY_DATE":"03/29/2000","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"122","PEL_DOSE_90":"101","SURVEY_TYPE":"I","sourceDate":"2000-03-29"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":23,"firstDate":"2000-01-19","lastDate":"2001-09-17","metrics":{"recentRows":0,"voidSamples":4,"maxQuartzPct":20.3,"validSamples":19,"quartzPctTotal":144.2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"12608","CASSETTE_NO":"50605058","SAMPLE_DT":"09/17/2001","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2001-09-17"},{"SOURCE_ROW_NUMBER":"20588","CASSETTE_NO":"57333853","SAMPLE_DT":"08/27/2001","QUARTZ_PCT":"11.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-08-27"},{"SOURCE_ROW_NUMBER":"19972","CASSETTE_NO":"57333833","SAMPLE_DT":"08/27/2001","QUARTZ_PCT":"04.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-08-27"},{"SOURCE_ROW_NUMBER":"157817","CASSETTE_NO":"50594743","SAMPLE_DT":"07/30/2001","QUARTZ_PCT":"05.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-07-30"},{"SOURCE_ROW_NUMBER":"50969","CASSETTE_NO":"50594733","SAMPLE_DT":"07/09/2001","QUARTZ_PCT":"02.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-07-09"},{"SOURCE_ROW_NUMBER":"10450","CASSETTE_NO":"57333453","SAMPLE_DT":"06/20/2001","QUARTZ_PCT":"20.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-06-20"},{"SOURCE_ROW_NUMBER":"125595","CASSETTE_NO":"50552110","SAMPLE_DT":"06/06/2001","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"UNACCEPTABLE TIMEFRAME","sourceDate":"2001-06-06"},{"SOURCE_ROW_NUMBER":"100593","CASSETTE_NO":"57304407","SAMPLE_DT":"04/03/2001","QUARTZ_PCT":"06.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-04-03"},{"SOURCE_ROW_NUMBER":"43516","CASSETTE_NO":"57304383","SAMPLE_DT":"04/03/2001","QUARTZ_PCT":"04.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-04-03"},{"SOURCE_ROW_NUMBER":"159084","CASSETTE_NO":"57301823","SAMPLE_DT":"02/08/2001","QUARTZ_PCT":"07.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-02-08"},{"SOURCE_ROW_NUMBER":"161694","CASSETTE_NO":"57294281","SAMPLE_DT":"12/06/2000","QUARTZ_PCT":"08.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-12-06"},{"SOURCE_ROW_NUMBER":"54554","CASSETTE_NO":"57294270","SAMPLE_DT":"12/06/2000","QUARTZ_PCT":"07.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-12-06"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":156,"firstDate":"2000-01-18","lastDate":"2002-09-23","metrics":{"ss":90,"amountDue":19596,"contested":0,"amountPaid":16458,"recentRows":0,"section104d":1,"unterminated":1,"proposedPenalty":19596},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2766135","VIOLATION_NO":"7215497","VIOLATION_ISSUE_DT":"09/23/2002","SIG_SUB":"Y","PART_SECTION":"75.701","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"3","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/23/2002","PROPOSED_PENALTY":"104","AMOUNT_DUE":"104","AMOUNT_PAID":"104","CONTESTED_IND":"N","sourceDate":"2002-09-23"},{"SOURCE_ROW_NUMBER":"2766134","VIOLATION_NO":"3567966","VIOLATION_ISSUE_DT":"09/23/2002","SIG_SUB":"Y","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/23/2002","PROPOSED_PENALTY":"83","AMOUNT_DUE":"83","AMOUNT_PAID":"83","CONTESTED_IND":"N","sourceDate":"2002-09-23"},{"SOURCE_ROW_NUMBER":"2766133","VIOLATION_NO":"3567965","VIOLATION_ISSUE_DT":"09/23/2002","SIG_SUB":"Y","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/23/2002","PROPOSED_PENALTY":"83","AMOUNT_DUE":"83","AMOUNT_PAID":"83","CONTESTED_IND":"N","sourceDate":"2002-09-23"},{"SOURCE_ROW_NUMBER":"2766179","VIOLATION_NO":"3568577","VIOLATION_ISSUE_DT":"08/20/2002","SIG_SUB":"Y","PART_SECTION":"75.333(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/20/2002","PROPOSED_PENALTY":"140","AMOUNT_DUE":"140","AMOUNT_PAID":"140","CONTESTED_IND":"N","sourceDate":"2002-08-20"},{"SOURCE_ROW_NUMBER":"2766178","VIOLATION_NO":"3568576","VIOLATION_ISSUE_DT":"08/20/2002","SIG_SUB":"Y","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/20/2002","PROPOSED_PENALTY":"104","AMOUNT_DUE":"104","AMOUNT_PAID":"104","CONTESTED_IND":"N","sourceDate":"2002-08-20"},{"SOURCE_ROW_NUMBER":"2766177","VIOLATION_NO":"3568575","VIOLATION_ISSUE_DT":"08/20/2002","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/20/2002","PROPOSED_PENALTY":"97","AMOUNT_DUE":"97","AMOUNT_PAID":"97","CONTESTED_IND":"N","sourceDate":"2002-08-20"},{"SOURCE_ROW_NUMBER":"2766132","VIOLATION_NO":"3568573","VIOLATION_ISSUE_DT":"06/24/2002","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/24/2002","PROPOSED_PENALTY":"161","AMOUNT_DUE":"161","AMOUNT_PAID":"161","CONTESTED_IND":"N","sourceDate":"2002-06-24"},{"SOURCE_ROW_NUMBER":"2766130","VIOLATION_NO":"3567920","VIOLATION_ISSUE_DT":"06/07/2002","SIG_SUB":"N","PART_SECTION":"75.340(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/12/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-06-07"},{"SOURCE_ROW_NUMBER":"2766129","VIOLATION_NO":"3567919","VIOLATION_ISSUE_DT":"06/07/2002","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/21/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-06-07"},{"SOURCE_ROW_NUMBER":"2766128","VIOLATION_NO":"3567918","VIOLATION_ISSUE_DT":"06/07/2002","SIG_SUB":"N","PART_SECTION":"75.1107-4(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/07/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-06-07"},{"SOURCE_ROW_NUMBER":"2766127","VIOLATION_NO":"3567916","VIOLATION_ISSUE_DT":"06/05/2002","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/07/2002","PROPOSED_PENALTY":"122","AMOUNT_DUE":"122","AMOUNT_PAID":"122","CONTESTED_IND":"N","sourceDate":"2002-06-05"},{"SOURCE_ROW_NUMBER":"2766126","VIOLATION_NO":"3567915","VIOLATION_ISSUE_DT":"06/05/2002","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/07/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-06-05"}]}],"safety":{"href":"/api/v1/mines/4608744/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4608744/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.701","heading":"Grounding metallic frames, casings, and other enclosures of electric equipment.","id":"75.701","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-H/section-75.701","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"H","subpartHeading":"Subpart H—Grounding","text":"[Statutory Provisions]\n\nMetallic frames, casings, and other enclosures of electric equipment that can become “alive” through failure of insulation or by contact with energized parts shall be grounded by methods approved by an authorized representative of the Secretary.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":4},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1725","heading":"Machinery and equipment; operation and maintenance.","id":"75.1725","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1725","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","heading":"Underground electrical installations.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.340","part":"75","subchapter":"O","subpart":"D","id":"75.340","citation":"30 CFR 75.340","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-4","heading":"Automatic fire sensors and manual actuators; installation; minimum requirements.","id":"75.1107-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a)(1) Where fire suppression devices are installed on unattended underground equipment, one or more point-type sensors or equivalent shall be installed for each 50 square feet of top surface area, or fraction thereof, of such equipment, and each sensor shall be designed to activate the first suppression system and disconnect the electrical power source to the equipment protected, and, except where sprinklers are used, there shall be in addition, a manual actuator installed to operate the system. Where sprinklers are used, provision shall be made for manual application of water to the protected equipment in lieu of a manual actuator.\n\n(2) Two or more manual actuators, where practicable, shall be installed, as provided in paragraphs (a)(2) (i) and (ii) of this section, to activate fire suppression devices on attended equipment purchased on or after the effective date of this § 75.1107-4. At least one manual actuator shall be used on equipment purchased prior to the effective date of this § 75.1107-4.\n\n(i) Manual actuators installed on attended equipment regularly operated by a miner, as provided in § 75.1107-1(c)(1) shall be located at different locations on the equipment, and at least one manual actuator shall be located within easy reach of the operator's normal operating position.\n\n(ii) Manual actuators to activate fire suppression devices on attended equipment not regularly operated by a miner, as provided in § 75.1107-1(c)(2), shall be installed at different location, and at least one manual actuator shall be installed so as to be easily reached by the miner at the jobsite or by persons approaching the equipment.\n\n(b) Sensors shall, where practicable, be installed in accordance with the recommendations set forth in National Fire Code No. 72A “Local Protective Signaling Systems” (NFPA No. 72A-1967).\n\n(c) On unattended equipment the fire suppression device shall operate independently of the power to the main motor (or equivalent) so it will remain operative if the circuit breakers (or other protective device) actuates. On attended equipment powered through a trailing cable the fire suppression device shall operate independently of the electrical power provided by the cable.\n\n(d) Point-type sensors (such as thermocouple, bimetallic strip, or rate of temperature rise) located in ventilated passageways shall be installed downwind from the equipment to be protected.\n\n(e) Sensor systems shall include a device or method for determining their operative condition.\n\n[37 FR 15301, July 29, 1972]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4608744","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}