{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4608625","name":"Kingston No 1","status":"Abandoned","status_date":"2020-06-15","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Fayette","nearest_town":"Kingston","operator_id":"P23860","operator_name":"Kingston Mining, Inc.","controller_id":"0127321","controller_name":"Alpha Metallurgical Resources Inc","district":"C04","office":"Beckley Field Office","employees":0,"latitude":37.931667,"longitude":-81.284722},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":19411},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4608625","name":"Kingston No 1"},"operator":{"type":"operator","id":"P23860","name":"Kingston Mining, Inc."},"controller":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C14727","name":"Brock Mining Inc"},"object":{"type":"mine","id":"4608625","name":"Kingston No 1"},"validFrom":"1992-09-21","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608625|C14727|1992-09-21|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22111","name":"Brock Mining Inc"},"object":{"type":"mine","id":"4608625","name":"Kingston No 1"},"validFrom":"1997-03-01","validTo":"1997-09-26","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608625|P22111|1997-03-01|1997-09-26"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14727","name":"Brock Mining Inc"},"object":{"type":"operator","id":"P22111","name":"Brock Mining Inc"},"validFrom":"1997-03-01","validTo":"1997-09-26","current":false,"derived":true,"evidenceMineId":"4608625","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608625|P22111|1997-03-01|C14727|1992-09-21|93702"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23860","name":"Kingston Mining, Inc."},"object":{"type":"mine","id":"4608625","name":"Kingston No 1"},"validFrom":"1997-09-27","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608625|P23860|1997-09-27|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15532","name":"Rag Aktiengesellschaft"},"object":{"type":"mine","id":"4608625","name":"Kingston No 1"},"validFrom":"1997-09-27","validTo":"2004-07-29","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608625|C15532|1997-09-27|2004-07-29"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15532","name":"Rag Aktiengesellschaft"},"object":{"type":"operator","id":"P23860","name":"Kingston Mining, Inc."},"validFrom":"1997-09-27","validTo":"2004-07-29","current":false,"derived":true,"evidenceMineId":"4608625","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608625|P23860|1997-09-27|C15532|1997-09-27|95874"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0044281","name":"Foundation Coal Corporation"},"object":{"type":"mine","id":"4608625","name":"Kingston No 1"},"validFrom":"2004-07-30","validTo":"2009-07-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608625|0044281|2004-07-30|2009-07-30"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0044281","name":"Foundation Coal Corporation"},"object":{"type":"operator","id":"P23860","name":"Kingston Mining, Inc."},"validFrom":"2004-07-30","validTo":"2009-07-30","current":false,"derived":true,"evidenceMineId":"4608625","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608625|P23860|1997-09-27|0044281|2004-07-30|4983"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"4608625","name":"Kingston No 1"},"validFrom":"2009-07-31","validTo":"2016-07-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608625|0041211|2009-07-31|2016-07-25"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P23860","name":"Kingston Mining, Inc."},"validFrom":"2009-07-31","validTo":"2016-07-25","current":false,"derived":true,"evidenceMineId":"4608625","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608625|P23860|1997-09-27|0041211|2009-07-31|1768"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"mine","id":"4608625","name":"Kingston No 1"},"validFrom":"2016-07-26","validTo":"2018-11-08","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608625|0127923|2016-07-26|2018-11-08"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"operator","id":"P23860","name":"Kingston Mining, Inc."},"validFrom":"2016-07-26","validTo":"2018-11-08","current":false,"derived":true,"evidenceMineId":"4608625","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608625|P23860|1997-09-27|0127923|2016-07-26|25227"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"mine","id":"4608625","name":"Kingston No 1"},"validFrom":"2018-11-09","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608625|0127321|2018-11-09|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"operator","id":"P23860","name":"Kingston Mining, Inc."},"validFrom":"2018-11-09","validTo":null,"current":true,"derived":true,"evidenceMineId":"4608625","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608625|P23860|1997-09-27|0127321|2018-11-09|24862"}}],"coverage":{"historyRecords":6,"edgeCount":14,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":173,"firstDate":"2000-01-28","lastDate":"2020-01-30","metrics":{"daysLost":7432,"injuries":164,"fatalities":1,"recentRows":0,"restrictedDays":48,"contractorRecords":13},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"257638","DOCUMENT_NO":"220200420023","ACCIDENT_DT":"01/30/2020","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Bodily reaction, NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"203","NARRATIVE":"Employee had exited the safety office, shut the door and stepped out onto dry level ground when EE's right ankle buckled resulting in a fracture. No event occurred to cause the injury. Classification is Degree 10.","sourceDate":"2020-01-30"},{"SOURCE_ROW_NUMBER":"162959","DOCUMENT_NO":"220192880046","ACCIDENT_DT":"09/27/2019","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee stated that on 9/27/2019, while operating a grinder, a small sliver of metal struck EE's left eye. This incident wasn't reported until 10/07/2019. The employee received medical treatment for the left eye, also on 10/7/2019. The incident became reportable at the time of the treatment. The employee did not miss any days work and had no restrictions from the doctor.","sourceDate":"2019-09-27"},{"SOURCE_ROW_NUMBER":"128290","DOCUMENT_NO":"220192490006","ACCIDENT_DT":"09/05/2019","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee has been diagnosed with simple occupational pneumoconiosis","sourceDate":"2019-09-05"},{"SOURCE_ROW_NUMBER":"184462","DOCUMENT_NO":"220192820011","ACCIDENT_DT":"07/17/2019","DEGREE_INJURY":"PERM TOT OR PERM PRTL DISABLTY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee stated that while lifting a toolbox off of the battery lid of a rubber tired ride on 07/17/2019, they strained abdominal region. The employee reported this incident on 07/18/2019. The employee was later diagnosed with a hernia and was treated for this issue on 10/1/2019. The employee did not miss any scheduled work and has no restrictions from thier doctor.","sourceDate":"2019-07-17"},{"SOURCE_ROW_NUMBER":"231786","DOCUMENT_NO":"220191690023","ACCIDENT_DT":"06/12/2019","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"An unplanned roof fall occurred in the left return. #1 entry at #1 break at the Town Creek portal.","sourceDate":"2019-06-12"},{"SOURCE_ROW_NUMBER":"68233","DOCUMENT_NO":"220190730017","ACCIDENT_DT":"03/03/2019","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While changing out a belt stand, employee pinched right hand between belt rail and stand resulting in stitches.","sourceDate":"2019-03-03"},{"SOURCE_ROW_NUMBER":"227506","DOCUMENT_NO":"220190370003","ACCIDENT_DT":"02/05/2019","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee has been diagnosed with simple workers pneumoconiosis","sourceDate":"2019-02-05"},{"SOURCE_ROW_NUMBER":"201542","DOCUMENT_NO":"220190370004","ACCIDENT_DT":"02/05/2019","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee has been diagnosed with workers pneumoconiosis.","sourceDate":"2019-02-05"},{"SOURCE_ROW_NUMBER":"180171","DOCUMENT_NO":"220190300032","ACCIDENT_DT":"01/24/2019","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee has been diagnosed with Occupational Pnemoconiosis.","sourceDate":"2019-01-24"},{"SOURCE_ROW_NUMBER":"257637","DOCUMENT_NO":"220190870026","ACCIDENT_DT":"12/04/2018","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"30","NARRATIVE":"While attempting to pull a rib, a piece broke off, causing the slate bar to jerk which resulted in a strained left shoulder to the employee. The employee continued to perform EE's normal job duties until rotator cuff surgery was done on 03/20/2019.","sourceDate":"2018-12-04"},{"SOURCE_ROW_NUMBER":"98239","DOCUMENT_NO":"220182880023","ACCIDENT_DT":"10/10/2018","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee states that while operating the continuous mining machine, a piece of debris was blown into right eye by the machine's scrubber fan. Employee finished shift and went to ER for treatment. Employee's right eye was flushed out and was treated with antibiotic eye drops.","sourceDate":"2018-10-10"},{"SOURCE_ROW_NUMBER":"214571","DOCUMENT_NO":"220181760001","ACCIDENT_DT":"06/08/2018","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"STRIKING OR BUMPING","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"253","NARRATIVE":"EE state that while fire bossing the #8 belt entry EE's head glanced off of the mine roof. EE notified the mine dispatcher approx. 10 minutes later. EE was met by EMT's at the #7 belt drive but refused initial treatment. EE was taken outside and transported to a hospital via ambulance. CT/MRI results show degenerative disease and arthritis affecting cervical vertebrae.","sourceDate":"2018-06-08"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2020-06-15","lastDate":"2020-06-15","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":3062,"firstDate":"2000-01-12","lastDate":"2020-05-27","metrics":{"ss":616,"delinquent":2987,"recentRows":0,"paidPenalty":2006339.26,"proposedPenalty":2734911,"currentAssessment":2264115.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1905038","VIOLATION_NO":"9245274","ISSUE_DT":"05/27/2020","CFR_STANDARD_CD":"77.1109(c)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"217.00","CURRENT_ASSESSMENT_AMT":"217.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-05-27"},{"SOURCE_ROW_NUMBER":"1902133","VIOLATION_NO":"9246197","ISSUE_DT":"03/10/2020","CFR_STANDARD_CD":"75.512-2","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"217.00","CURRENT_ASSESSMENT_AMT":"217.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"1902132","VIOLATION_NO":"9246196","ISSUE_DT":"03/10/2020","CFR_STANDARD_CD":"77.502-2","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"720.00","CURRENT_ASSESSMENT_AMT":"720.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"1902131","VIOLATION_NO":"9246195","ISSUE_DT":"03/10/2020","CFR_STANDARD_CD":"77.800-1(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2041.00","CURRENT_ASSESSMENT_AMT":"721.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"1902130","VIOLATION_NO":"9246194","ISSUE_DT":"03/10/2020","CFR_STANDARD_CD":"75.900-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"720.00","CURRENT_ASSESSMENT_AMT":"720.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"1902129","VIOLATION_NO":"9246193","ISSUE_DT":"03/09/2020","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"185.00","CURRENT_ASSESSMENT_AMT":"185.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-03-09"},{"SOURCE_ROW_NUMBER":"1902128","VIOLATION_NO":"9246192","ISSUE_DT":"03/05/2020","CFR_STANDARD_CD":"75.333(d)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"412.00","CURRENT_ASSESSMENT_AMT":"412.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-03-05"},{"SOURCE_ROW_NUMBER":"1902127","VIOLATION_NO":"9246191","ISSUE_DT":"03/03/2020","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"615.00","CURRENT_ASSESSMENT_AMT":"615.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-03-03"},{"SOURCE_ROW_NUMBER":"1902126","VIOLATION_NO":"9246190","ISSUE_DT":"03/02/2020","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"4922.00","CURRENT_ASSESSMENT_AMT":"2211.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-03-02"},{"SOURCE_ROW_NUMBER":"1902125","VIOLATION_NO":"9246189","ISSUE_DT":"03/02/2020","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1884.00","CURRENT_ASSESSMENT_AMT":"847.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-03-02"},{"SOURCE_ROW_NUMBER":"1902124","VIOLATION_NO":"9246188","ISSUE_DT":"02/20/2020","CFR_STANDARD_CD":"75.1403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"412.00","CURRENT_ASSESSMENT_AMT":"412.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-02-20"},{"SOURCE_ROW_NUMBER":"1902123","VIOLATION_NO":"9246187","ISSUE_DT":"02/20/2020","CFR_STANDARD_CD":"75.1731(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"782.00","CURRENT_ASSESSMENT_AMT":"782.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-02-20"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":558,"firstDate":"2008-09-16","lastDate":"2020-11-09","metrics":{"appeals":0,"decisions":558,"recentRows":0,"decisionPenalty":1054856.5,"originalPenalty":1585817},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"422817","VIOLATION_NO":"9246163","DOCKET_NO":"WEVA 2020-0414","DECISION_DT":"11/09/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"482.00","DECISION_PENALTY_AMT":"482.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2020-11-09"},{"SOURCE_ROW_NUMBER":"421897","VIOLATION_NO":"9246164","DOCKET_NO":"WEVA 2020-0414","DECISION_DT":"11/09/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1076.00","DECISION_PENALTY_AMT":"218.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2020-11-09"},{"SOURCE_ROW_NUMBER":"421896","VIOLATION_NO":"9246159","DOCKET_NO":"WEVA 2020-0414","DECISION_DT":"11/09/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"378.00","DECISION_PENALTY_AMT":"378.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2020-11-09"},{"SOURCE_ROW_NUMBER":"421376","VIOLATION_NO":"9246162","DOCKET_NO":"WEVA 2020-0414","DECISION_DT":"11/09/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"482.00","DECISION_PENALTY_AMT":"482.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2020-11-09"},{"SOURCE_ROW_NUMBER":"421375","VIOLATION_NO":"9246161","DOCKET_NO":"WEVA 2020-0414","DECISION_DT":"11/09/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1076.00","DECISION_PENALTY_AMT":"218.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2020-11-09"},{"SOURCE_ROW_NUMBER":"423232","VIOLATION_NO":"9246170","DOCKET_NO":"WEVA 2020-0511","DECISION_DT":"09/21/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2595.00","DECISION_PENALTY_AMT":"2595.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2020-09-21"},{"SOURCE_ROW_NUMBER":"421250","VIOLATION_NO":"9240811","DOCKET_NO":"WEVA 2020-0365","DECISION_DT":"08/24/2020","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"190.00","DECISION_PENALTY_AMT":"190.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2020-08-24"},{"SOURCE_ROW_NUMBER":"144228","VIOLATION_NO":"9240801","DOCKET_NO":"WEVA 2020-0365","DECISION_DT":"08/24/2020","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"801.00","DECISION_PENALTY_AMT":"801.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2020-08-24"},{"SOURCE_ROW_NUMBER":"144103","VIOLATION_NO":"9240813","DOCKET_NO":"WEVA 2020-0365","DECISION_DT":"08/24/2020","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"190.00","DECISION_PENALTY_AMT":"190.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2020-08-24"},{"SOURCE_ROW_NUMBER":"422180","VIOLATION_NO":"9246182","DOCKET_NO":"WEVA 2020-0366","DECISION_DT":"08/19/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"123.00","DECISION_PENALTY_AMT":"123.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2020-08-19"},{"SOURCE_ROW_NUMBER":"422179","VIOLATION_NO":"9163023","DOCKET_NO":"WEVA 2020-0366","DECISION_DT":"08/19/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"482.00","DECISION_PENALTY_AMT":"482.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2020-08-19"},{"SOURCE_ROW_NUMBER":"421347","VIOLATION_NO":"9240812","DOCKET_NO":"WEVA 2020-0366","DECISION_DT":"08/19/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"378.00","DECISION_PENALTY_AMT":"378.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2020-08-19"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":7831,"firstDate":"2000-01-10","lastDate":"2020-06-19","metrics":{"recentRows":0,"cpdmSamples":2217,"voidSamples":1123,"validSamples":6708,"maxConcentration":32.315,"concentrationTotal":4812.95},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2467894","SMP_TAKEN_DT":"6/19/2020","CONC":".009","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"DISPATCHER","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-06-19"},{"SOURCE_ROW_NUMBER":"2383782","SMP_TAKEN_DT":"6/18/2020","CONC":"0","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"DISPATCHER","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-06-18"},{"SOURCE_ROW_NUMBER":"2212823","SMP_TAKEN_DT":"6/15/2020","CONC":".016","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"DISPATCHER","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-06-15"},{"SOURCE_ROW_NUMBER":"179880","CASS_NUM":"58395760","SMP_TAKEN_DT":"6/12/2020","CONC":".057","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"DISPATCHER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2020-06-12"},{"SOURCE_ROW_NUMBER":"2980404","SMP_TAKEN_DT":"6/11/2020","CONC":".039","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"DISPATCHER","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-06-11"},{"SOURCE_ROW_NUMBER":"2809860","SMP_TAKEN_DT":"6/10/2020","CONC":".435","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"DISPATCHER","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-06-10"},{"SOURCE_ROW_NUMBER":"2042206","SMP_TAKEN_DT":"6/9/2020","CONC":".146","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"DISPATCHER","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-06-09"},{"SOURCE_ROW_NUMBER":"2810554","SMP_TAKEN_DT":"4/14/2020","CONC":".014","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-04-14"},{"SOURCE_ROW_NUMBER":"2725142","SMP_TAKEN_DT":"4/13/2020","CONC":".029","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-04-13"},{"SOURCE_ROW_NUMBER":"1787915","SMP_TAKEN_DT":"4/9/2020","CONC":".001","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"Miner is not active with QnC","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-04-09"},{"SOURCE_ROW_NUMBER":"2554800","SMP_TAKEN_DT":"4/8/2020","CONC":".039","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-04-08"},{"SOURCE_ROW_NUMBER":"2383293","SMP_TAKEN_DT":"4/6/2020","CONC":".059","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-04-06"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":214,"firstDate":"2001-01-10","lastDate":"2020-08-24","metrics":{"linkedIssuances":214},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":558,"firstDate":"2007-05-22","lastDate":"2020-03-10","metrics":{"decisions":558,"ssChanged":127,"recentRows":0,"decisionPenalty":1054856.5,"proposedPenalty":1585817},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"330320","CITATION_NO":"9246195","CITATION_ISSUE_DT":"03/10/2020","DOCKET_NO":"WEVA 2020-0430","DECISION_DT":"08/07/2020","CFR_STANDARD_CODE":"77.800-1(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"2041.00","DECISION_PENALTY_AMT":"721.00","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"215878","CITATION_NO":"9246197","CITATION_ISSUE_DT":"03/10/2020","DOCKET_NO":"WEVA 2020-0366","DECISION_DT":"08/19/2020","CFR_STANDARD_CODE":"75.512-2","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"217.00","DECISION_PENALTY_AMT":"217.00","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"104247","CITATION_NO":"9246194","CITATION_ISSUE_DT":"03/10/2020","DOCKET_NO":"WEVA 2020-0430","DECISION_DT":"08/07/2020","CFR_STANDARD_CODE":"75.900-3","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"720.00","DECISION_PENALTY_AMT":"720.00","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"46610","CITATION_NO":"9246196","CITATION_ISSUE_DT":"03/10/2020","DOCKET_NO":"WEVA 2020-0430","DECISION_DT":"08/07/2020","CFR_STANDARD_CODE":"77.502-2","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"720.00","DECISION_PENALTY_AMT":"720.00","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"217008","CITATION_NO":"9246193","CITATION_ISSUE_DT":"03/09/2020","DOCKET_NO":"WEVA 2020-0430","DECISION_DT":"08/07/2020","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"185.00","DECISION_PENALTY_AMT":"185.00","sourceDate":"2020-03-09"},{"SOURCE_ROW_NUMBER":"215969","CITATION_NO":"9246192","CITATION_ISSUE_DT":"03/05/2020","DOCKET_NO":"WEVA 2020-0430","DECISION_DT":"08/07/2020","CFR_STANDARD_CODE":"75.333(d)(3)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"412.00","DECISION_PENALTY_AMT":"412.00","sourceDate":"2020-03-05"},{"SOURCE_ROW_NUMBER":"272470","CITATION_NO":"9246191","CITATION_ISSUE_DT":"03/03/2020","DOCKET_NO":"WEVA 2020-0430","DECISION_DT":"08/07/2020","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"615.00","DECISION_PENALTY_AMT":"615.00","sourceDate":"2020-03-03"},{"SOURCE_ROW_NUMBER":"385733","CITATION_NO":"9246189","CITATION_ISSUE_DT":"03/02/2020","DOCKET_NO":"WEVA 2020-0430","DECISION_DT":"08/07/2020","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1884.00","DECISION_PENALTY_AMT":"847.00","sourceDate":"2020-03-02"},{"SOURCE_ROW_NUMBER":"274360","CITATION_NO":"9246190","CITATION_ISSUE_DT":"03/02/2020","DOCKET_NO":"WEVA 2020-0430","DECISION_DT":"08/07/2020","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"4922.00","DECISION_PENALTY_AMT":"2211.00","sourceDate":"2020-03-02"},{"SOURCE_ROW_NUMBER":"213084","CITATION_NO":"9246186","CITATION_ISSUE_DT":"02/20/2020","DOCKET_NO":"WEVA 2020-0430","DECISION_DT":"08/07/2020","CFR_STANDARD_CODE":"75.1731(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"234.00","DECISION_PENALTY_AMT":"234.00","sourceDate":"2020-02-20"},{"SOURCE_ROW_NUMBER":"160362","CITATION_NO":"9246188","CITATION_ISSUE_DT":"02/20/2020","DOCKET_NO":"WEVA 2020-0430","DECISION_DT":"08/07/2020","CFR_STANDARD_CODE":"75.1403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"412.00","DECISION_PENALTY_AMT":"412.00","sourceDate":"2020-02-20"},{"SOURCE_ROW_NUMBER":"385771","CITATION_NO":"9246184","CITATION_ISSUE_DT":"02/19/2020","DOCKET_NO":"WEVA 2020-0430","DECISION_DT":"08/07/2020","CFR_STANDARD_CODE":"75.1731(b)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"234.00","DECISION_PENALTY_AMT":"234.00","sourceDate":"2020-02-19"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":2226,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":14,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":370,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":14,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":6,"firstDate":"1997-03-01","lastDate":"1997-09-27","metrics":{"recentRows":0,"currentOperatorTenures":5,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":251,"firstDate":"2000-01-03","lastDate":"2020-06-12","metrics":{"inspectors":555,"recentRows":0,"onSiteHours":17572,"inspectionHours":27045.75,"inspectionSamples":3111},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"249978","EVENT_NO":"6313582","INSPECTION_BEGIN_DT":"06/12/2020","INSPECTION_END_DT":"06/12/2020","ACTIVITY_CODE":"E22","ACTIVITY":"Health Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2020-06-12"},{"SOURCE_ROW_NUMBER":"984484","EVENT_NO":"6314981","INSPECTION_BEGIN_DT":"04/01/2020","INSPECTION_END_DT":"06/26/2020","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"69.75","SUM_TOTAL_ON_SITE_HOURS":"50","sourceDate":"2020-04-01"},{"SOURCE_ROW_NUMBER":"261195","EVENT_NO":"6314240","INSPECTION_BEGIN_DT":"01/02/2020","INSPECTION_END_DT":"03/18/2020","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"209.25","SUM_TOTAL_ON_SITE_HOURS":"148","sourceDate":"2020-01-02"},{"SOURCE_ROW_NUMBER":"935391","EVENT_NO":"6313695","INSPECTION_BEGIN_DT":"10/08/2019","INSPECTION_END_DT":"10/08/2019","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2019-10-08"},{"SOURCE_ROW_NUMBER":"223792","EVENT_NO":"6316151","INSPECTION_BEGIN_DT":"10/01/2019","INSPECTION_END_DT":"12/19/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"320.25","SUM_TOTAL_ON_SITE_HOURS":"213.5","sourceDate":"2019-10-01"},{"SOURCE_ROW_NUMBER":"650830","EVENT_NO":"6312986","INSPECTION_BEGIN_DT":"07/15/2019","INSPECTION_END_DT":"09/30/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"348.5","SUM_TOTAL_ON_SITE_HOURS":"233","sourceDate":"2019-07-15"},{"SOURCE_ROW_NUMBER":"446122","EVENT_NO":"6311529","INSPECTION_BEGIN_DT":"06/13/2019","INSPECTION_END_DT":"06/24/2019","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"25","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2019-06-13"},{"SOURCE_ROW_NUMBER":"891323","EVENT_NO":"6314014","INSPECTION_BEGIN_DT":"04/01/2019","INSPECTION_END_DT":"06/27/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"326.5","SUM_TOTAL_ON_SITE_HOURS":"204","sourceDate":"2019-04-01"},{"SOURCE_ROW_NUMBER":"1064028","EVENT_NO":"6312730","INSPECTION_BEGIN_DT":"03/26/2019","INSPECTION_END_DT":"03/26/2019","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.75","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2019-03-26"},{"SOURCE_ROW_NUMBER":"810085","EVENT_NO":"6312727","INSPECTION_BEGIN_DT":"01/03/2019","INSPECTION_END_DT":"03/18/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"331.75","SUM_TOTAL_ON_SITE_HOURS":"238.75","sourceDate":"2019-01-03"},{"SOURCE_ROW_NUMBER":"911638","EVENT_NO":"6312725","INSPECTION_BEGIN_DT":"10/01/2018","INSPECTION_END_DT":"12/19/2018","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"8","SUM_TOTAL_INSP_HOURS":"447.25","SUM_TOTAL_ON_SITE_HOURS":"296","sourceDate":"2018-10-01"},{"SOURCE_ROW_NUMBER":"995395","EVENT_NO":"6308994","INSPECTION_BEGIN_DT":"07/02/2018","INSPECTION_END_DT":"09/18/2018","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"6","SUM_TOTAL_INSP_HOURS":"436.75","SUM_TOTAL_ON_SITE_HOURS":"285","sourceDate":"2018-07-02"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":185,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2020-Q2":{"hours":8452,"employees":16,"production":0},"2020-Q1":{"hours":30903,"employees":50,"production":22752},"2019-Q4":{"hours":37137,"employees":66,"production":44961},"2019-Q3":{"hours":40363,"employees":69,"production":42962},"2019-Q2":{"hours":43596,"employees":72,"production":48317},"2019-Q1":{"hours":43888,"employees":72,"production":50288},"2018-Q4":{"hours":39365,"employees":69,"production":44950},"2018-Q3":{"hours":38057,"employees":70,"production":45890},"2018-Q2":{"hours":38997,"employees":67,"production":45407},"2018-Q1":{"hours":42737,"employees":70,"production":47336},"2017-Q4":{"hours":40786,"employees":74,"production":43983},"2017-Q3":{"hours":43005,"employees":80,"production":45276}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":45,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2011":{"hours":243424,"employees":98,"production":585367},"2012":{"hours":275213,"employees":111,"production":516408},"2013":{"hours":291036,"employees":127,"production":342139},"2014":{"hours":289806,"employees":129,"production":444852},"2015":{"hours":290600,"employees":129,"production":378662},"2016":{"hours":172452,"employees":83,"production":258103},"2017":{"hours":173232,"employees":75,"production":185848},"2018":{"hours":159156,"employees":69,"production":183583},"2019":{"hours":164984,"employees":70,"production":186528},"2020":{"hours":39355,"employees":33,"production":22752}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":260,"firstDate":"2000-02-29","lastDate":"2019-12-02","metrics":{"recentRows":0,"doseOver100":102,"actDoseTotal":24936,"pelDoseTotal":19580},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"239529","EVENT_NO":"6316151","SURVEY_DATE":"12/02/2019","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"37","PEL_DOSE_90":"18","SURVEY_TYPE":"I","sourceDate":"2019-12-02"},{"SOURCE_ROW_NUMBER":"239528","EVENT_NO":"6316151","SURVEY_DATE":"12/02/2019","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"35","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2019-12-02"},{"SOURCE_ROW_NUMBER":"239527","EVENT_NO":"6316151","SURVEY_DATE":"12/02/2019","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"82","PEL_DOSE_90":"66","SURVEY_TYPE":"I","sourceDate":"2019-12-02"},{"SOURCE_ROW_NUMBER":"239526","EVENT_NO":"6316151","SURVEY_DATE":"12/02/2019","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"85","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2019-12-02"},{"SOURCE_ROW_NUMBER":"239520","EVENT_NO":"6316151","SURVEY_DATE":"11/20/2019","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"53","PEL_DOSE_90":"28","SURVEY_TYPE":"F","sourceDate":"2019-11-20"},{"SOURCE_ROW_NUMBER":"239519","EVENT_NO":"6316151","SURVEY_DATE":"11/20/2019","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"85","PEL_DOSE_90":"62","SURVEY_TYPE":"F","sourceDate":"2019-11-20"},{"SOURCE_ROW_NUMBER":"239518","EVENT_NO":"6316151","SURVEY_DATE":"11/20/2019","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"96","PEL_DOSE_90":"74","SURVEY_TYPE":"F","sourceDate":"2019-11-20"},{"SOURCE_ROW_NUMBER":"239517","EVENT_NO":"6316151","SURVEY_DATE":"11/20/2019","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"84","PEL_DOSE_90":"62","SURVEY_TYPE":"F","sourceDate":"2019-11-20"},{"SOURCE_ROW_NUMBER":"239516","EVENT_NO":"6316151","SURVEY_DATE":"11/20/2019","OCCUPATION_CD_DESC":"ROCK DUSTER","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"90","PEL_DOSE_90":"58","SURVEY_TYPE":"F","sourceDate":"2019-11-20"},{"SOURCE_ROW_NUMBER":"239525","EVENT_NO":"6316151","SURVEY_DATE":"11/18/2019","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"22","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2019-11-18"},{"SOURCE_ROW_NUMBER":"239524","EVENT_NO":"6316151","SURVEY_DATE":"11/18/2019","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"24","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2019-11-18"},{"SOURCE_ROW_NUMBER":"239523","EVENT_NO":"6316151","SURVEY_DATE":"11/18/2019","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"29","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2019-11-18"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":561,"firstDate":"2000-01-19","lastDate":"2019-12-03","metrics":{"recentRows":0,"voidSamples":47,"maxQuartzPct":27.3,"validSamples":514,"quartzPctTotal":2594.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"92553","CASSETTE_NO":"58404862","SAMPLE_DT":"12/03/2019","QUARTZ_PCT":"06.9","QUARTZ_MICROGRAMS":"10","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-12-03"},{"SOURCE_ROW_NUMBER":"62723","CASSETTE_NO":"58404442","SAMPLE_DT":"12/03/2019","QUARTZ_PCT":"02.6","QUARTZ_MICROGRAMS":"14","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-12-03"},{"SOURCE_ROW_NUMBER":"31464","CASSETTE_NO":"58404725","SAMPLE_DT":"12/03/2019","QUARTZ_PCT":"06.8","QUARTZ_MICROGRAMS":"17","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-12-03"},{"SOURCE_ROW_NUMBER":"155332","CASSETTE_NO":"58404886","SAMPLE_DT":"11/20/2019","QUARTZ_PCT":"05.3","QUARTZ_MICROGRAMS":"39","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-11-20"},{"SOURCE_ROW_NUMBER":"99680","CASSETTE_NO":"58404810","SAMPLE_DT":"11/20/2019","QUARTZ_PCT":"04.4","QUARTZ_MICROGRAMS":"26","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-11-20"},{"SOURCE_ROW_NUMBER":"18199","CASSETTE_NO":"58404877","SAMPLE_DT":"11/20/2019","QUARTZ_PCT":"02.5","QUARTZ_MICROGRAMS":"12","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-11-20"},{"SOURCE_ROW_NUMBER":"125498","CASSETTE_NO":"58362093","SAMPLE_DT":"07/30/2019","QUARTZ_PCT":"03.5","QUARTZ_MICROGRAMS":"22","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-07-30"},{"SOURCE_ROW_NUMBER":"19183","CASSETTE_NO":"58361783","SAMPLE_DT":"07/30/2019","QUARTZ_PCT":"04.1","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-07-30"},{"SOURCE_ROW_NUMBER":"7633","CASSETTE_NO":"58361755","SAMPLE_DT":"07/30/2019","QUARTZ_PCT":"04.2","QUARTZ_MICROGRAMS":"24","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-07-30"},{"SOURCE_ROW_NUMBER":"140727","CASSETTE_NO":"58361903","SAMPLE_DT":"07/23/2019","QUARTZ_PCT":"04.7","QUARTZ_MICROGRAMS":"12","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-07-23"},{"SOURCE_ROW_NUMBER":"119781","CASSETTE_NO":"58362066","SAMPLE_DT":"07/23/2019","QUARTZ_PCT":"05.0","QUARTZ_MICROGRAMS":"16","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-07-23"},{"SOURCE_ROW_NUMBER":"93719","CASSETTE_NO":"58361868","SAMPLE_DT":"07/23/2019","QUARTZ_PCT":"03.9","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-07-23"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":3109,"firstDate":"2000-01-12","lastDate":"2020-05-27","metrics":{"ss":619,"amountDue":2264115.5,"contested":59,"amountPaid":2006339.26,"recentRows":0,"section104d":4,"unterminated":7,"proposedPenalty":2734911},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2742341","VIOLATION_NO":"9245274","VIOLATION_ISSUE_DT":"05/27/2020","SIG_SUB":"N","PART_SECTION":"77.1109(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/27/2020","PROPOSED_PENALTY":"217","AMOUNT_DUE":"217","AMOUNT_PAID":"217","CONTESTED_IND":"N","sourceDate":"2020-05-27"},{"SOURCE_ROW_NUMBER":"2741631","VIOLATION_NO":"9246197","VIOLATION_ISSUE_DT":"03/10/2020","SIG_SUB":"N","PART_SECTION":"75.512-2","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/11/2020","PROPOSED_PENALTY":"217","AMOUNT_DUE":"217","AMOUNT_PAID":"217","CONTESTED_IND":"N","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"2741630","VIOLATION_NO":"9246196","VIOLATION_ISSUE_DT":"03/10/2020","SIG_SUB":"N","PART_SECTION":"77.502-2","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/11/2020","PROPOSED_PENALTY":"720","AMOUNT_DUE":"720","AMOUNT_PAID":"720","CONTESTED_IND":"N","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"2741629","VIOLATION_NO":"9246195","VIOLATION_ISSUE_DT":"03/10/2020","SIG_SUB":"N","PART_SECTION":"77.800-1(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/11/2020","PROPOSED_PENALTY":"2041","AMOUNT_DUE":"721","AMOUNT_PAID":"721","CONTESTED_IND":"N","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"2741628","VIOLATION_NO":"9246194","VIOLATION_ISSUE_DT":"03/10/2020","SIG_SUB":"N","PART_SECTION":"75.900-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/11/2020","PROPOSED_PENALTY":"720","AMOUNT_DUE":"720","AMOUNT_PAID":"720","CONTESTED_IND":"N","sourceDate":"2020-03-10"},{"SOURCE_ROW_NUMBER":"2741627","VIOLATION_NO":"9246193","VIOLATION_ISSUE_DT":"03/09/2020","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/09/2020","PROPOSED_PENALTY":"185","AMOUNT_DUE":"185","AMOUNT_PAID":"185","CONTESTED_IND":"N","sourceDate":"2020-03-09"},{"SOURCE_ROW_NUMBER":"2741626","VIOLATION_NO":"9246192","VIOLATION_ISSUE_DT":"03/05/2020","SIG_SUB":"N","PART_SECTION":"75.333(d)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"8","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/05/2020","PROPOSED_PENALTY":"412","AMOUNT_DUE":"412","AMOUNT_PAID":"412","CONTESTED_IND":"N","sourceDate":"2020-03-05"},{"SOURCE_ROW_NUMBER":"2741625","VIOLATION_NO":"9246191","VIOLATION_ISSUE_DT":"03/03/2020","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/05/2020","PROPOSED_PENALTY":"615","AMOUNT_DUE":"615","AMOUNT_PAID":"615","CONTESTED_IND":"N","sourceDate":"2020-03-03"},{"SOURCE_ROW_NUMBER":"2741624","VIOLATION_NO":"9246190","VIOLATION_ISSUE_DT":"03/02/2020","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"14","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/03/2020","PROPOSED_PENALTY":"4922","AMOUNT_DUE":"2211","AMOUNT_PAID":"2211","CONTESTED_IND":"N","sourceDate":"2020-03-02"},{"SOURCE_ROW_NUMBER":"2741623","VIOLATION_NO":"9246189","VIOLATION_ISSUE_DT":"03/02/2020","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"4","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/03/2020","PROPOSED_PENALTY":"1884","AMOUNT_DUE":"847","AMOUNT_PAID":"847","CONTESTED_IND":"N","sourceDate":"2020-03-02"},{"SOURCE_ROW_NUMBER":"2741622","VIOLATION_NO":"9246188","VIOLATION_ISSUE_DT":"02/20/2020","SIG_SUB":"N","PART_SECTION":"75.1403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/24/2020","PROPOSED_PENALTY":"412","AMOUNT_DUE":"412","AMOUNT_PAID":"412","CONTESTED_IND":"N","sourceDate":"2020-02-20"},{"SOURCE_ROW_NUMBER":"2741621","VIOLATION_NO":"9246187","VIOLATION_ISSUE_DT":"02/20/2020","SIG_SUB":"N","PART_SECTION":"75.1731(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"02/20/2020","PROPOSED_PENALTY":"782","AMOUNT_DUE":"782","AMOUNT_PAID":"782","CONTESTED_IND":"N","sourceDate":"2020-02-20"}]}],"safety":{"href":"/api/v1/mines/4608625/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4608625/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512-2","heading":"Frequency of examinations.","id":"75.512-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"The examinations and tests required by § 75.512 shall be made at least weekly. Permissible equipment shall be examined to see that it is in permissible condition.","occurrenceCount":1},{"chapter":"I","heading":"Electric equipment; frequency of examination and testing.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502-2","part":"77","subchapter":"O","subpart":"F","id":"77.502-2","citation":"30 CFR 77.502-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Testing, examination, and maintenance of circuit breakers; procedures.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-I/section-77.800-1","part":"77","subchapter":"O","subpart":"I","id":"77.800-1","citation":"30 CFR 77.800-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Testing, examination, and maintenance of circuit breakers; procedures.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-J/section-75.900-3","part":"75","subchapter":"O","subpart":"J","id":"75.900-3","citation":"30 CFR 75.900-3","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.403","heading":"Maintenance of incombustible content of rock dust.","id":"75.403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 80 percent. Where methane is present in any ventilating current, the percent of incombustible content of such combined dust shall be increased 0.4 percent for each 0.1 percent of methane.\n\n[75 FR 57857, Sept. 23, 2010; 76 FR 35978, June 21, 2011]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403","heading":"Other safeguards.","id":"75.1403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"[Statutory Provisions]\n\nOther safeguards adequate, in the judgment of an authorized representative of the Secretary, to minimize hazards with respect to transportation of men and materials shall be provided.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1731","heading":"Maintenance of belt conveyors and belt conveyor entries.","id":"75.1731","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1731","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Damaged rollers, or other damaged belt conveyor components, which pose a fire hazard must be immediately repaired or replaced. All other damaged rollers, or other damaged belt conveyor components, must be repaired or replaced.\n\n(b) Conveyor belts must be properly aligned to prevent the moving belt from rubbing against the structure or components.\n\n(c) Materials shall not be allowed in the belt conveyor entry where the material may contribute to a frictional heating hazard.\n\n(d) Splicing of any approved conveyor belt must maintain flame-resistant properties of the belt.\n\n[73 FR 80616, Dec. 31, 2008]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4608625","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}