{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4608603","name":"Cedar Grove Mine","status":"Abandoned","status_date":"2002-12-31","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Raleigh","nearest_town":"Montcoal","operator_id":"P21654","operator_name":"Independence Coal Company Inc","controller_id":"0127923","controller_name":"Alpha Natural Resources Holdings, Inc","district":"C04","office":"Beckley Field Office","employees":0,"latitude":37.928333,"longitude":-81.584722},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":1726},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4608603","name":"Cedar Grove Mine"},"operator":{"type":"operator","id":"P21654","name":"Independence Coal Company Inc"},"controller":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"mine","id":"4608603","name":"Cedar Grove Mine"},"validFrom":"1991-12-01","validTo":"2011-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608603|C02508|1991-12-01|2011-05-31"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P21654","name":"Independence Coal Company Inc"},"object":{"type":"mine","id":"4608603","name":"Cedar Grove Mine"},"validFrom":"1996-10-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608603|P21654|1996-10-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"P21654","name":"Independence Coal Company Inc"},"validFrom":"1996-10-01","validTo":"2011-05-31","current":false,"derived":true,"evidenceMineId":"4608603","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608603|P21654|1996-10-01|C02508|1991-12-01|59276"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"4608603","name":"Cedar Grove Mine"},"validFrom":"2011-06-01","validTo":"2016-07-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608603|0041211|2011-06-01|2016-07-25"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P21654","name":"Independence Coal Company Inc"},"validFrom":"2011-06-01","validTo":"2016-07-25","current":false,"derived":true,"evidenceMineId":"4608603","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608603|P21654|1996-10-01|0041211|2011-06-01|2124"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"mine","id":"4608603","name":"Cedar Grove Mine"},"validFrom":"2016-07-26","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608603|0127923|2016-07-26|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"operator","id":"P21654","name":"Independence Coal Company Inc"},"validFrom":"2016-07-26","validTo":null,"current":true,"derived":true,"evidenceMineId":"4608603","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608603|P21654|1996-10-01|0127923|2016-07-26|25587"}}],"coverage":{"historyRecords":3,"edgeCount":7,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":34,"firstDate":"2000-01-20","lastDate":"2002-07-23","metrics":{"daysLost":750,"injuries":25,"fatalities":1,"recentRows":0,"restrictedDays":24,"contractorRecords":14},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"261986","DOCUMENT_NO":"220022100108","ACCIDENT_DT":"07/23/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Mine manager, Mine foreman, Mine owner","NO_INJURIES":"1","DAYS_LOST":"47","NARRATIVE":"EE WAS LOADING WATER LINE WHEN HE SLIPPED ON A ROCK, TWISTED HIS ANKLE & THEN FELL.","sourceDate":"2002-07-23"},{"SOURCE_ROW_NUMBER":"102518","DOCUMENT_NO":"220013120045","ACCIDENT_DT":"10/25/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Miner, NEC","NO_INJURIES":"1","DAYS_LOST":"7","NARRATIVE":"EE WAS HELPING ALIGN THE MOVEMENT OF A SECTION OF BATHHOUSE, AS HE WAS MOVING A PIPE THE BATHHOUSE WAS LOWERED ON HIS RIGHT HAND.","sourceDate":"2001-10-25"},{"SOURCE_ROW_NUMBER":"184453","DOCUMENT_NO":"220012540001","ACCIDENT_DT":"08/27/2001","DEGREE_INJURY":"FATALITY","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","NARRATIVE":"EE OPERATING THE CONTINUOUS MINER IN THE #5 ENTRY WHEN A PIECE OF ROCK BROW FELL STRIKING HIM FROM BEHIND RESULTING IN FATAL INJURIES.","sourceDate":"2001-08-27"},{"SOURCE_ROW_NUMBER":"188639","DOCUMENT_NO":"220012180044","ACCIDENT_DT":"07/30/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"AN UNPLANNED ROOF FALL OCCURRED ON 7/30/01. DISTANCE FROM ACTIVE FACE IS 2400'. THERE WERE NO PERSONAL INJURIES AND NO EQUIPMENT INVOLVED. SIZE OF FALL IS APPROXIMATELY 20' X 20' X 8'. ALL ENT RANCES TO FALL HAVE BEEN TIMBERED OFF.","sourceDate":"2001-07-30"},{"SOURCE_ROW_NUMBER":"231779","DOCUMENT_NO":"220012060012","ACCIDENT_DT":"07/19/2001","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","NARRATIVE":"EE WAS GREASING THE FEEDER WHEN A SECTION OF RIB FELL AND STRUCK HIM ON THE HEAD AND UPPER BACK. INJURED HAD 2 STAPLES PUT IN HIS HEAD.","sourceDate":"2001-07-19"},{"SOURCE_ROW_NUMBER":"192970","DOCUMENT_NO":"220012060013","ACCIDENT_DT":"07/18/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"AN UNPLANNED ROOF FALL OCCURRED AROUND 7-18-01. DISTANCE FROM ACTIVE FACE WAS APPROX. 2000'. THERE WERE NO PERSONNEL INJURIES OR EQUIPMENT INVOLVED. SIZE OF FALL MEASURED 20' X 20' X 8'.","sourceDate":"2001-07-18"},{"SOURCE_ROW_NUMBER":"25407","DOCUMENT_NO":"220011940067","ACCIDENT_DT":"07/08/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"AN UNPLANNED ROOF FALL OCCURRED. DISTURBANCE FROM ACTIVE FACE WAS ~4000'. NO INJURIES & NO EQUIPMENT INVOLVED. SIZE 80' X 20' IN NEUTRAL ENTRY. ALL ENTRIES TO FALL HAVE BEEN BREAKERED OFF.","sourceDate":"2001-07-08"},{"SOURCE_ROW_NUMBER":"3854","DOCUMENT_NO":"220011490057","ACCIDENT_DT":"05/15/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"59","NARRATIVE":"AFTER COMPLETEING HIS SHIFT EE WAS WALKING IN THE PARKING LOT WHEN HIS ANKLE GAVE WAY FOR NO APPARENT REASON.","sourceDate":"2001-05-15"},{"SOURCE_ROW_NUMBER":"274695","DOCUMENT_NO":"220011300011","ACCIDENT_DT":"05/05/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"1 BREAK OUTBY SPAD # 347 #5 ENTRY IN MAINS. DISTANCE FROM ACTING FACE IS APPROX. 1100 FT. NO PERSONAL INJURIES AND NO EQUIPMENT WAS INVOLVED. SIZE OF FALL MEASURED 20' X 19' X 9'","sourceDate":"2001-05-05"},{"SOURCE_ROW_NUMBER":"210255","DOCUMENT_NO":"220010160090","ACCIDENT_DT":"01/03/2001","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","NARRATIVE":"INJURED WAS ATTEMPTING TO MEASURE THE LENGTH OF A BELT ROLLER WHILE THE BELT WAS RUNNING. HE TRIED TO MEASURE THE BOTTOM ROLLER BY STRETCHING THE TAPELINE UNDERNEATH THE BELT. WHILE DOING SO, HIS ARM WAS CAUGHT BETWEEN THE ROLLER AND THE BOTTOM.","sourceDate":"2001-01-03"},{"SOURCE_ROW_NUMBER":"33936","DOCUMENT_NO":"220002760141","ACCIDENT_DT":"09/28/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"60","NARRATIVE":"LOADING STRUCTURE ON SCOOP BUCKET - SLIPPED AND FELL WITH ROLLER FALLING ON HAND. CUT 2 FINGERS,POSSIBLE BROKE.","sourceDate":"2000-09-28"},{"SOURCE_ROW_NUMBER":"29570","DOCUMENT_NO":"220002570023","ACCIDENT_DT":"09/07/2000","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"AN UNPLANNED ROOF FALL OCCURRED AT THE LONGWALL FACE. THERE WERE NO PERSONAL INJURIES. LONGWALL SHIELDS 60-76 WERE INVOLVED. VENTILATION WAS NOT AFFECTED, NOR WAS PASSAGE OF PERSONS. SIZE OF FALL: 100' X 6' X 6'. 6' TORQUE TENSION AND 8' CABLE BOLTS WERE BEING USED. DISTANCE ABOVE MINING SEAM 2-6' W/THICKNESS OF 1\"-24\"; FALL AREA WILL BE REHABILITATED. MSHA NOTIFIED AT SITE","sourceDate":"2000-09-07"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2002-12-31","lastDate":"2002-12-31","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":173,"firstDate":"1999-01-10","lastDate":"2002-07-11","metrics":{"ss":92,"delinquent":173,"recentRows":0,"paidPenalty":64832,"proposedPenalty":314582,"currentAssessment":64832},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1587681","VIOLATION_NO":"4641934","ISSUE_DT":"07/11/2002","CFR_STANDARD_CD":"75.1712-3(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-07-11"},{"SOURCE_ROW_NUMBER":"1587680","VIOLATION_NO":"4641933","ISSUE_DT":"07/10/2002","CFR_STANDARD_CD":"75.523-3(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"207.00","CURRENT_ASSESSMENT_AMT":"207.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-07-10"},{"SOURCE_ROW_NUMBER":"1587679","VIOLATION_NO":"4641932","ISSUE_DT":"07/03/2002","CFR_STANDARD_CD":"75.364(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"294.00","CURRENT_ASSESSMENT_AMT":"294.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-07-03"},{"SOURCE_ROW_NUMBER":"1587678","VIOLATION_NO":"4641930","ISSUE_DT":"07/03/2002","CFR_STANDARD_CD":"75.360(a)(2)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"294.00","CURRENT_ASSESSMENT_AMT":"294.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-07-03"},{"SOURCE_ROW_NUMBER":"1587677","VIOLATION_NO":"4641929","ISSUE_DT":"07/03/2002","CFR_STANDARD_CD":"75.362(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"294.00","CURRENT_ASSESSMENT_AMT":"294.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-07-03"},{"SOURCE_ROW_NUMBER":"772416","VIOLATION_NO":"7213581","ISSUE_DT":"02/07/2002","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1815.00","CURRENT_ASSESSMENT_AMT":"1815.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-02-07"},{"SOURCE_ROW_NUMBER":"768621","VIOLATION_NO":"7205808","ISSUE_DT":"11/07/2001","CFR_STANDARD_CD":"75.362(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"55000.00","CURRENT_ASSESSMENT_AMT":"0.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-11-07"},{"SOURCE_ROW_NUMBER":"768620","VIOLATION_NO":"7205807","ISSUE_DT":"11/07/2001","CFR_STANDARD_CD":"75.360(b)(3)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"55000.00","CURRENT_ASSESSMENT_AMT":"0.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-11-07"},{"SOURCE_ROW_NUMBER":"768618","VIOLATION_NO":"7205805","ISSUE_DT":"11/07/2001","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"55000.00","CURRENT_ASSESSMENT_AMT":"10000.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-11-07"},{"SOURCE_ROW_NUMBER":"768617","VIOLATION_NO":"7205804","ISSUE_DT":"11/07/2001","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55000.00","CURRENT_ASSESSMENT_AMT":"10000.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-11-07"},{"SOURCE_ROW_NUMBER":"768625","VIOLATION_NO":"7205827","ISSUE_DT":"10/24/2001","CFR_STANDARD_CD":"75.1107-4(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-10-24"},{"SOURCE_ROW_NUMBER":"768624","VIOLATION_NO":"7205826","ISSUE_DT":"10/24/2001","CFR_STANDARD_CD":"75.523-3(b)(3)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"317.00","CURRENT_ASSESSMENT_AMT":"317.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-10-24"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":6,"firstDate":"2004-06-15","lastDate":"2004-06-15","metrics":{"appeals":0,"decisions":6,"recentRows":0,"decisionPenalty":34750,"originalPenalty":284500},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"482239","VIOLATION_NO":"7205803","DOCKET_NO":"WEVA20020144","DECISION_DT":"06/15/2004","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"9500.00","DECISION_PENALTY_AMT":"4750.00","JUDGE_FIRST_NAME":"T","JUDGE_LAST_NAME":"Hodgdon","sourceDate":"2004-06-15"},{"SOURCE_ROW_NUMBER":"482111","VIOLATION_NO":"7205804","DOCKET_NO":"WEVA20020138","DECISION_DT":"06/15/2004","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"55000.00","DECISION_PENALTY_AMT":"10000.00","JUDGE_FIRST_NAME":"T","JUDGE_LAST_NAME":"Hodgdon","sourceDate":"2004-06-15"},{"SOURCE_ROW_NUMBER":"481981","VIOLATION_NO":"7205807","DOCKET_NO":"WEVA20020138","DECISION_DT":"06/15/2004","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"55000.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"T","JUDGE_LAST_NAME":"Hodgdon","sourceDate":"2004-06-15"},{"SOURCE_ROW_NUMBER":"481980","VIOLATION_NO":"7205806","DOCKET_NO":"WEVA20020138","DECISION_DT":"06/15/2004","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"55000.00","DECISION_PENALTY_AMT":"10000.00","JUDGE_FIRST_NAME":"T","JUDGE_LAST_NAME":"Hodgdon","sourceDate":"2004-06-15"},{"SOURCE_ROW_NUMBER":"180374","VIOLATION_NO":"7205808","DOCKET_NO":"WEVA20020138","DECISION_DT":"06/15/2004","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"55000.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"T","JUDGE_LAST_NAME":"Hodgdon","sourceDate":"2004-06-15"},{"SOURCE_ROW_NUMBER":"179831","VIOLATION_NO":"7205805","DOCKET_NO":"WEVA20020138","DECISION_DT":"06/15/2004","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"55000.00","DECISION_PENALTY_AMT":"10000.00","JUDGE_FIRST_NAME":"T","JUDGE_LAST_NAME":"Hodgdon","sourceDate":"2004-06-15"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":219,"firstDate":"2000-01-04","lastDate":"2001-08-14","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":15,"validSamples":204,"maxConcentration":18.135,"concentrationTotal":174.606},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1433212","CASS_NUM":"57332941","SMP_TAKEN_DT":"8/14/2001","CONC":".3","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-14"},{"SOURCE_ROW_NUMBER":"1186889","CASS_NUM":"57332943","SMP_TAKEN_DT":"8/14/2001","CONC":".116","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-14"},{"SOURCE_ROW_NUMBER":"972686","CASS_NUM":"57332928","SMP_TAKEN_DT":"8/14/2001","CONC":".401","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-14"},{"SOURCE_ROW_NUMBER":"660947","CASS_NUM":"57332935","SMP_TAKEN_DT":"8/14/2001","CONC":".124","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-14"},{"SOURCE_ROW_NUMBER":"648079","CASS_NUM":"57332900","SMP_TAKEN_DT":"8/14/2001","CONC":".114","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-14"},{"SOURCE_ROW_NUMBER":"410516","CASS_NUM":"57332981","SMP_TAKEN_DT":"8/14/2001","CONC":".282","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-14"},{"SOURCE_ROW_NUMBER":"280294","CASS_NUM":"57332881","SMP_TAKEN_DT":"8/14/2001","CONC":".135","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-14"},{"SOURCE_ROW_NUMBER":"168574","CASS_NUM":"57332919","SMP_TAKEN_DT":"8/14/2001","CONC":".336","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-14"},{"SOURCE_ROW_NUMBER":"98824","CASS_NUM":"57332961","SMP_TAKEN_DT":"8/14/2001","CONC":".06","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-14"},{"SOURCE_ROW_NUMBER":"81985","CASS_NUM":"57332954","SMP_TAKEN_DT":"8/14/2001","CONC":".233","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-14"},{"SOURCE_ROW_NUMBER":"1497712","CASS_NUM":"50613390","SMP_TAKEN_DT":"8/4/2001","CONC":".858","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-04"},{"SOURCE_ROW_NUMBER":"1012849","CASS_NUM":"50613387","SMP_TAKEN_DT":"8/4/2001","CONC":".541","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-04"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":15,"firstDate":"2000-03-20","lastDate":"2001-12-04","metrics":{"linkedIssuances":15},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":800,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":5,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":169,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":5,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"1996-10-01","lastDate":"1996-10-01","metrics":{"recentRows":0,"currentOperatorTenures":3,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":66,"firstDate":"2000-01-03","lastDate":"2003-01-08","metrics":{"inspectors":86,"recentRows":0,"onSiteHours":1108.75,"inspectionHours":2096.75,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1057806","EVENT_NO":"4094146","INSPECTION_BEGIN_DT":"01/08/2003","INSPECTION_END_DT":"04/01/2003","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2003-01-08"},{"SOURCE_ROW_NUMBER":"727835","EVENT_NO":"4094138","INSPECTION_BEGIN_DT":"10/17/2002","INSPECTION_END_DT":"12/31/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2002-10-17"},{"SOURCE_ROW_NUMBER":"878316","EVENT_NO":"4101855","INSPECTION_BEGIN_DT":"10/07/2002","INSPECTION_END_DT":"10/08/2002","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2002-10-07"},{"SOURCE_ROW_NUMBER":"55996","EVENT_NO":"5808033","INSPECTION_BEGIN_DT":"07/03/2002","INSPECTION_END_DT":"08/29/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"62.5","SUM_TOTAL_ON_SITE_HOURS":"38.5","sourceDate":"2002-07-03"},{"SOURCE_ROW_NUMBER":"804404","EVENT_NO":"4100301","INSPECTION_BEGIN_DT":"06/17/2002","INSPECTION_END_DT":"06/17/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2002-06-17"},{"SOURCE_ROW_NUMBER":"290621","EVENT_NO":"4093133","INSPECTION_BEGIN_DT":"04/23/2002","INSPECTION_END_DT":"04/25/2002","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2002-04-23"},{"SOURCE_ROW_NUMBER":"402152","EVENT_NO":"4095085","INSPECTION_BEGIN_DT":"01/02/2002","INSPECTION_END_DT":"03/08/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"31.5","SUM_TOTAL_ON_SITE_HOURS":"9.5","sourceDate":"2002-01-02"},{"SOURCE_ROW_NUMBER":"590399","EVENT_NO":"4093528","INSPECTION_BEGIN_DT":"12/18/2001","INSPECTION_END_DT":"12/18/2001","ACTIVITY_CODE":"CDB","ACTIVITY":"ACCIDENT PREVENTION SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2001-12-18"},{"SOURCE_ROW_NUMBER":"481389","EVENT_NO":"4093523","INSPECTION_BEGIN_DT":"10/09/2001","INSPECTION_END_DT":"12/18/2001","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"100","SUM_TOTAL_ON_SITE_HOURS":"62.5","sourceDate":"2001-10-09"},{"SOURCE_ROW_NUMBER":"761788","EVENT_NO":"4095954","INSPECTION_BEGIN_DT":"09/05/2001","INSPECTION_END_DT":"09/05/2001","ACTIVITY_CODE":"BBF","ACTIVITY":"PART 50 AUDITS","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2001-09-05"},{"SOURCE_ROW_NUMBER":"336365","EVENT_NO":"4093522","INSPECTION_BEGIN_DT":"08/28/2001","INSPECTION_END_DT":"10/10/2001","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"61.5","SUM_TOTAL_ON_SITE_HOURS":"49.5","sourceDate":"2001-08-28"},{"SOURCE_ROW_NUMBER":"749676","EVENT_NO":"4093521","INSPECTION_BEGIN_DT":"08/27/2001","INSPECTION_END_DT":"01/18/2002","ACTIVITY_CODE":"AFA","ACTIVITY":"FATAL ACCIDENT INVESTIGATION","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"255","SUM_TOTAL_ON_SITE_HOURS":"75.5","sourceDate":"2001-08-27"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":23,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002-Q4":{"hours":0,"employees":0,"production":0},"2002-Q3":{"hours":616,"employees":2,"production":0},"2002-Q2":{"hours":280,"employees":2,"production":0},"2002-Q1":{"hours":1690,"employees":6,"production":0},"2001-Q4":{"hours":5012,"employees":23,"production":0},"2001-Q3":{"hours":18976,"employees":40,"production":33795},"2001-Q2":{"hours":24859,"employees":41,"production":118252},"2001-Q1":{"hours":24025,"employees":42,"production":103976},"2000-Q4":{"hours":20156,"employees":41,"production":63637},"2000-Q3":{"hours":37774,"employees":52,"production":163426},"2000-Q2":{"hours":39672,"employees":60,"production":251259},"2000-Q1":{"hours":43787,"employees":64,"production":96292}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":5,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":141389,"employees":54,"production":574614},"2001":{"hours":72872,"employees":37,"production":256023},"2002":{"hours":2586,"employees":3,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":15,"firstDate":"2000-02-24","lastDate":"2001-08-01","metrics":{"recentRows":0,"doseOver100":4,"actDoseTotal":1145,"pelDoseTotal":896},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"239126","EVENT_NO":"4094971","SURVEY_DATE":"08/01/2001","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"28","PEL_DOSE_90":"12","SURVEY_TYPE":"F","sourceDate":"2001-08-01"},{"SOURCE_ROW_NUMBER":"239125","EVENT_NO":"4094970","SURVEY_DATE":"07/25/2001","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"11","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2001-07-25"},{"SOURCE_ROW_NUMBER":"239124","EVENT_NO":"4094970","SURVEY_DATE":"07/25/2001","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"56","PEL_DOSE_90":"37","SURVEY_TYPE":"I","sourceDate":"2001-07-25"},{"SOURCE_ROW_NUMBER":"239123","EVENT_NO":"4094970","SURVEY_DATE":"07/25/2001","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"20","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2001-07-25"},{"SOURCE_ROW_NUMBER":"239122","EVENT_NO":"4094970","SURVEY_DATE":"07/25/2001","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"25","PEL_DOSE_90":"14","SURVEY_TYPE":"I","sourceDate":"2001-07-25"},{"SOURCE_ROW_NUMBER":"239121","EVENT_NO":"4094970","SURVEY_DATE":"07/25/2001","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"27","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2001-07-25"},{"SOURCE_ROW_NUMBER":"239120","EVENT_NO":"4093514","SURVEY_DATE":"04/17/2001","OCCUPATION_CD_DESC":"MINE FOREMAN/MINE MANAGER","ACT_DOSE_85":"48","PEL_DOSE_90":"34","SURVEY_TYPE":"I","sourceDate":"2001-04-17"},{"SOURCE_ROW_NUMBER":"239119","EVENT_NO":"4093514","SURVEY_DATE":"04/17/2001","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"45","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2001-04-17"},{"SOURCE_ROW_NUMBER":"239118","EVENT_NO":"4093514","SURVEY_DATE":"04/17/2001","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"69","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2001-04-17"},{"SOURCE_ROW_NUMBER":"239117","EVENT_NO":"4093514","SURVEY_DATE":"04/17/2001","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"104","PEL_DOSE_90":"84","SURVEY_TYPE":"I","sourceDate":"2001-04-17"},{"SOURCE_ROW_NUMBER":"239116","EVENT_NO":"4093514","SURVEY_DATE":"04/17/2001","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"229","PEL_DOSE_90":"219","SURVEY_TYPE":"I","sourceDate":"2001-04-17"},{"SOURCE_ROW_NUMBER":"239115","EVENT_NO":"4081650","SURVEY_DATE":"02/24/2000","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"120","ACT_DOSE_85":"219","PEL_DOSE_90":"203","SURVEY_TYPE":"I","sourceDate":"2000-02-24"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":18,"firstDate":"2000-01-06","lastDate":"2001-06-27","metrics":{"recentRows":0,"voidSamples":2,"maxQuartzPct":18.1,"validSamples":16,"quartzPctTotal":107.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"37741","CASSETTE_NO":"57332519","SAMPLE_DT":"06/27/2001","QUARTZ_PCT":"06.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-06-27"},{"SOURCE_ROW_NUMBER":"39713","CASSETTE_NO":"57332465","SAMPLE_DT":"04/17/2001","QUARTZ_PCT":"05.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-04-17"},{"SOURCE_ROW_NUMBER":"80507","CASSETTE_NO":"57332389","SAMPLE_DT":"04/11/2001","QUARTZ_PCT":"02.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-04-11"},{"SOURCE_ROW_NUMBER":"86456","CASSETTE_NO":"57305917","SAMPLE_DT":"02/12/2001","QUARTZ_PCT":"06.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-02-12"},{"SOURCE_ROW_NUMBER":"26233","CASSETTE_NO":"57305902","SAMPLE_DT":"02/12/2001","QUARTZ_PCT":"06.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-02-12"},{"SOURCE_ROW_NUMBER":"143463","CASSETTE_NO":"57306022","SAMPLE_DT":"01/08/2001","QUARTZ_PCT":"03.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-01-08"},{"SOURCE_ROW_NUMBER":"52593","CASSETTE_NO":"57305541","SAMPLE_DT":"10/23/2000","QUARTZ_PCT":"06.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-10-23"},{"SOURCE_ROW_NUMBER":"108735","CASSETTE_NO":"57267094","SAMPLE_DT":"08/02/2000","QUARTZ_PCT":"01.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-08-02"},{"SOURCE_ROW_NUMBER":"152553","CASSETTE_NO":"57267389","SAMPLE_DT":"08/01/2000","QUARTZ_PCT":"07.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-08-01"},{"SOURCE_ROW_NUMBER":"30807","CASSETTE_NO":"57267310","SAMPLE_DT":"07/26/2000","QUARTZ_PCT":"06.8","OCC_CODE_DESC":"LONGWALL(RETURN-SIDE FACE WORKER)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-07-26"},{"SOURCE_ROW_NUMBER":"30630","CASSETTE_NO":"50530769","SAMPLE_DT":"06/26/2000","OCC_CODE_DESC":"LONGWALL(RETURN-SIDE FACE WORKER)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"OVERSIZE PARTICLES","sourceDate":"2000-06-26"},{"SOURCE_ROW_NUMBER":"85907","CASSETTE_NO":"57258002","SAMPLE_DT":"05/17/2000","QUARTZ_PCT":"18.1","OCC_CODE_DESC":"LONGWALL(RETURN-SIDE FACE WORKER)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-05-17"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":178,"firstDate":"1999-01-10","lastDate":"2002-07-11","metrics":{"ss":93,"amountDue":64832,"contested":6,"amountPaid":64832,"recentRows":0,"section104d":8,"unterminated":2,"proposedPenalty":314582},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2739505","VIOLATION_NO":"4641934","VIOLATION_ISSUE_DT":"07/11/2002","SIG_SUB":"N","PART_SECTION":"75.1712-3(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"07/15/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-07-11"},{"SOURCE_ROW_NUMBER":"2739504","VIOLATION_NO":"4641933","VIOLATION_ISSUE_DT":"07/10/2002","SIG_SUB":"Y","PART_SECTION":"75.523-3(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/10/2002","PROPOSED_PENALTY":"207","AMOUNT_DUE":"207","AMOUNT_PAID":"207","CONTESTED_IND":"N","sourceDate":"2002-07-10"},{"SOURCE_ROW_NUMBER":"2739503","VIOLATION_NO":"4641932","VIOLATION_ISSUE_DT":"07/03/2002","SIG_SUB":"Y","PART_SECTION":"75.364(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"5","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/09/2002","PROPOSED_PENALTY":"294","AMOUNT_DUE":"294","AMOUNT_PAID":"294","CONTESTED_IND":"N","sourceDate":"2002-07-03"},{"SOURCE_ROW_NUMBER":"2739502","VIOLATION_NO":"4641930","VIOLATION_ISSUE_DT":"07/03/2002","SIG_SUB":"Y","PART_SECTION":"75.360(a)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"5","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/09/2002","PROPOSED_PENALTY":"294","AMOUNT_DUE":"294","AMOUNT_PAID":"294","CONTESTED_IND":"N","sourceDate":"2002-07-03"},{"SOURCE_ROW_NUMBER":"2739501","VIOLATION_NO":"4641929","VIOLATION_ISSUE_DT":"07/03/2002","SIG_SUB":"Y","PART_SECTION":"75.362(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"5","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/09/2002","PROPOSED_PENALTY":"294","AMOUNT_DUE":"294","AMOUNT_PAID":"294","CONTESTED_IND":"N","sourceDate":"2002-07-03"},{"SOURCE_ROW_NUMBER":"2739439","VIOLATION_NO":"7213586","VIOLATION_ISSUE_DT":"02/14/2002","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"04/15/2003","CONTESTED_IND":"N","sourceDate":"2002-02-14"},{"SOURCE_ROW_NUMBER":"2739438","VIOLATION_NO":"7213581","VIOLATION_ISSUE_DT":"02/07/2002","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"1815","AMOUNT_DUE":"1815","AMOUNT_PAID":"1815","CONTESTED_IND":"N","sourceDate":"2002-02-07"},{"SOURCE_ROW_NUMBER":"2739565","VIOLATION_NO":"7205808","VIOLATION_ISSUE_DT":"11/07/2001","SIG_SUB":"Y","PART_SECTION":"75.362(a)(1)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Occurred","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"Reckless","TERMINATION_DT":"11/07/2001","PROPOSED_PENALTY":"55000","AMOUNT_DUE":"0","AMOUNT_PAID":"0","CONTESTED_IND":"Y","DOCKET_NO":"WEVA20020138","sourceDate":"2001-11-07"},{"SOURCE_ROW_NUMBER":"2739564","VIOLATION_NO":"7205807","VIOLATION_ISSUE_DT":"11/07/2001","SIG_SUB":"Y","PART_SECTION":"75.360(b)(3)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Occurred","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"Reckless","TERMINATION_DT":"11/07/2001","PROPOSED_PENALTY":"55000","AMOUNT_DUE":"0","AMOUNT_PAID":"0","CONTESTED_IND":"Y","DOCKET_NO":"WEVA20020138","sourceDate":"2001-11-07"},{"SOURCE_ROW_NUMBER":"2739562","VIOLATION_NO":"7205805","VIOLATION_ISSUE_DT":"11/07/2001","SIG_SUB":"Y","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Occurred","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"Reckless","TERMINATION_DT":"11/07/2001","PROPOSED_PENALTY":"55000","AMOUNT_DUE":"10000","AMOUNT_PAID":"10000","CONTESTED_IND":"Y","DOCKET_NO":"WEVA20020138","sourceDate":"2001-11-07"},{"SOURCE_ROW_NUMBER":"2739561","VIOLATION_NO":"7205804","VIOLATION_ISSUE_DT":"11/07/2001","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"NoNegligence","TERMINATION_DT":"11/07/2001","PROPOSED_PENALTY":"55000","AMOUNT_DUE":"10000","AMOUNT_PAID":"10000","CONTESTED_IND":"Y","DOCKET_NO":"WEVA20020138","sourceDate":"2001-11-07"},{"SOURCE_ROW_NUMBER":"2739606","VIOLATION_NO":"7205827","VIOLATION_ISSUE_DT":"10/24/2001","SIG_SUB":"N","PART_SECTION":"75.1107-4(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/07/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-10-24"}]}],"safety":{"href":"/api/v1/mines/4608603/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4608603/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Minimum requirements of surface bathing facilities, change rooms, and sanitary toilet facilities.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1712-3","part":"75","subchapter":"O","subpart":"R","id":"75.1712-3","citation":"30 CFR 75.1712-3","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.523-3","heading":"Automatic emergency-parking brakes.","id":"75.523-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"(a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking brakes in accordance with the following schedule.\n\n(1) On and after May 23, 1989—\n\n(i) All new equipment ordered; and\n\n(ii) All equipment originally furnished with or retrofitted with automatic emergency-parking brakes which meet the requirements of this section.\n\n(2) On and after May 23, 1991, all other equipment.\n\n(b) Automatic emergency-parking brakes shall—\n\n(1) Be activated immediately by the emergency deenergization device required by 30 CFR 75.523-1 and 75.523-2;\n\n(2) Engage automatically within 5.0 seconds when the equipment is deenergized;\n\n(3) Safely bring the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(4) Hold the equipment stationary despite any contraction of brake parts, exhaustion of any non-mechanical source of energy, or leakage; and\n\n(5) Release only by a manual control that does not operate any other equipment function.\n\n(c) Automatic emergency-parking brakes shall include a means in the equipment operator's compartment to—\n\n(1) Apply the brakes manually without deenergizing the equipment; and\n\n(2) Release and reengage the brakes without energizing the equipment.\n\n(d) On and after November 24, 1989, rubber-tired, self-propelled electric face equipment not covered by paragraph (a) of this section shall be equipped with a means incorporated on the equipment and operable from each tramming station to hold the equipment stationary—\n\n(1) On the maximum grade on which it is operated; and\n\n(2) Despite any contraction of components, exhaustion of any non-mechanical source of energy, or leakage.\n\n(e) The brake systems required by paragraphs (a) or (d) of this section shall be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n[54 FR 12412, Mar. 24, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.364","heading":"Weekly examination.","id":"75.364","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.364","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Worked-out areas. (1) At least every 7 days, a certified person shall examine unsealed worked-out areas where no pillars have been recovered by traveling to the area of deepest penetration; measuring methane and oxygen concentrations and air quantities and making tests to determine if the air is moving in the proper direction in the area. The locations of measurement points where tests and measurements will be performed shall be included in the mine ventilation plan and shall be adequate in number and location to assure ventilation and air quality in the area. Air quantity measurements shall also be made where the air enters and leaves the worked-out area. An alternative method of evaluating the ventilation of the area may be approved in the ventilation plan.\n\n(2) At least every 7 days, a certified person shall evaluate the effectiveness of bleeder systems required by § 75.334 as follows:\n\n(i) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in its proper direction shall be made where air enters the worked-out area.\n\n(ii) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in the proper direction shall be made immediately before the air enters a return split of air.\n\n(iii) At least one entry of each set of bleeder entries used as part of a bleeder system under § 75.334 shall be traveled in its entirety. Measurements of methane and oxygen concentrations and air quantities and a test to determine if the air is moving in the proper direction shall be made at the measurement point locations specified in the mine ventilation plan to determine the effectiveness of the bleeder system.\n\n(iv) In lieu of the requirements of paragraphs (a)(2)(i) and (iii) of this section, an alternative method of evaluation may be specified in the ventilation plan provided the alternative method results in proper evaluation of the effectiveness of the bleeder system.\n\n(b) Hazardous conditions and violations of mandatory health or safety standards. At least every 7 days, an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(8) of this section shall be made by a certified person designated by the operator at the following locations:\n\n(1) In at least one entry of each intake air course, in its entirety, so that the entire air course is traveled.\n\n(2) In at least one entry of each return air course, in its entirety, so that the entire air course is traveled.\n\n(3) In each longwall or shortwall travelway in its entirety, so that the entire travelway is traveled.\n\n(4) At each seal along return and bleeder air courses and at each seal along intake air courses not examined under § 75.360(b)(5).\n\n(5) In each escapeway so that the entire escapeway is traveled.\n\n(6) On each working section not examined under § 75.360(b)(3) during the previous 7 days.\n\n(7) At each water pump not examined during a preshift examination conducted during the previous 7 days.\n\n(8) Weekly examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust; and\n\n(iv) § 75.1403—maintenance of off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) Measurements and tests. At least every 7 days, a certified person shall—\n\n(1) Determine the volume of air entering the main intakes and in each intake split;\n\n(2) Determine the volume of air and test for methane in the last open crosscut in any pair or set of developing entries or rooms, in the return of each split of air immediately before it enters the main returns, and where the air leaves the main returns; and\n\n(3) Test for methane in the return entry nearest each set of seals immediately after the air passes the seals.\n\n(d) Hazardous conditions shall be corrected immediately. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Any violation of the nine mandatory health or safety standards found during a weekly examination shall be corrected.\n\n(e) The weekly examination may be conducted at the same time as the preshift or on-shift examinations.\n\n(f) (1) The weekly examination is not required during any 7 day period in which no one enters any underground area of the mine.\n\n(2) Except for certified persons required to make examinations, no one shall enter any underground area of the mine if a weekly examination has not been completed within the previous 7 days.\n\n(g) Certification. The person making the weekly examinations shall certify by initials, date, and the time that the examination was made. Certifications and times shall appear at enough locations to show that the entire area has been examined.\n\n(h) Recordkeeping. At the completion of any shift during which a portion of a weekly examination is conducted, a record of the results of each weekly examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards found during each examination and their locations, the corrective action taken, and the results and location of air and methane measurements, shall be made. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the person making the examination or a person designated by the operator. If made by a person other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(i) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 77 FR 20715, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.360","heading":"Preshift examination at fixed intervals.","id":"75.360","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.360","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) Except as provided in paragraph (a)(2) of this section, a certified person designated by the operator must make a preshift examination within 3 hours preceding the beginning of any 8-hour interval during which any person is scheduled to work or travel underground. No person other than certified examiners may enter or remain in any underground area unless a preshift examination has been completed for the established 8-hour interval. The operator must establish 8-hour intervals of time subject to the required preshift examinations.\n\n(2) Preshift examinations of areas where pumpers are scheduled to work or travel shall not be required prior to the pumper entering the areas if the pumper is a certified person and the pumper conducts an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, tests for methane and oxygen deficiency, and determines if the air is moving in its proper direction in the area where the pumper works or travels. The examination of the area must be completed before the pumper performs any other work. A record of all hazardous conditions and violations of the mandatory health or safety standards found by the pumper shall be made and retained in accordance with § 75.363 of this part.\n\n(b) The person conducting the preshift examination shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction at the following locations:\n\n(1) Roadways, travelways and track haulageways where persons are scheduled, prior to the beginning of the preshift examination, to work or travel during the oncoming shift.\n\n(2) Belt conveyors that will be used to transport persons during the oncoming shift and the entries in which these belt conveyors are located.\n\n(3) Working sections and areas where mechanized mining equipment is being installed or removed, if anyone is scheduled to work on the section or in the area during the oncoming shift. The scope of the examination shall include the working places, approaches to worked-out areas and ventilation controls on these sections and in these areas, and the examination shall include tests of the roof, face and rib conditions on these sections and in these areas.\n\n(4) Approaches to worked-out areas along intake air courses and at the entries used to carry air into worked-out areas if the intake air passing the approaches is used to ventilate working sections where anyone is scheduled to work during the oncoming shift. The examination of the approaches to the worked-out areas shall be made in the intake air course immediately inby and outby each entry used to carry air into the worked-out area. An examination of the entries used to carry air into the worked-out areas shall be conducted at a point immediately inby the intersection of each entry with the intake air course.\n\n(5) Seals along intake air courses where intake air passes by a seal to ventilate working sections where anyone is scheduled to work during the oncoming shift.\n\n(6)(i) Entries and rooms developed after November 15, 1992, and developed more than 2 crosscuts off an intake air course without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift; and,\n\n(ii) Entries and rooms developed after November 15, 1992, and driven more than 20 feet off an intake air course without a crosscut and without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift.\n\n(7) Areas where trolley wires or trolley feeder wires are to be or will remain energized during the oncoming shift.\n\n(8) High spots along intake air courses where methane is likely to accumulate, if equipment will be operated in the area during the shift.\n\n(9) Underground electrical installations referred to in § 75.340(a), except those pumps listed in § 75.340 (b)(2) through (b)(6), and areas where compressors subject to § 75.344 are installed if the electrical installation or compressor is or will be energized during the shift.\n\n(10) Other areas where work or travel during the oncoming shift is scheduled prior to the beginning of the preshift examination.\n\n(11) Preshift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) The person conducting the preshift examination shall determine the volume of air entering each of the following areas if anyone is scheduled to work in the areas during the oncoming shift:\n\n(1) In the last open crosscut of each set of entries or rooms on each working section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) On each longwall or shortwall in the intake entry or entries at the intake end of the longwall or shortwall face immediately outby the face and the velocity of air at each end of the face at the locations specified in the approved ventilation plan.\n\n(3) At the intake end of any pillar line—\n\n(i) If a single split of air is used, in the intake entry furthest from the return air course, immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) If a split system is used, in the intake entries of each split immediately inby the split point.\n\n(d) The person conducting the preshift examination shall check the refuge alternative for damage, the integrity of the tamper-evident seal and the mechanisms required to deploy the refuge alternative, and the ready availability of compressed oxygen and air.\n\n(e) The district manager may require the operator to examine other areas of the mine or examine for other hazards and violations of other mandatory health or safety standards found during the preshift examination.\n\n(f) Certification. At each working place examined, the person doing the preshift examination shall certify by initials, date, and the time, that the examination was made. In areas required to be examined outby a working section, the certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(g) Recordkeeping. A record of the results of each preshift examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards and their locations found by the examiner during each examination, and of the results and locations of air and methane measurements, shall be made on the surface before any persons, other than certified persons conducting examinations required by this subpart, enter any underground area of the mine. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the certified person who made the examination or by a person designated by the operator. If the record is made by someone other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. A record shall also be made by a certified person of the action taken to correct hazardous conditions and violations of mandatory health or safety standards found during the preshift examination. All preshift and corrective action records shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(h) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 62 FR 35085, June 30, 1997; 64 FR 45170, Aug. 19, 1999; 73 FR 80697, Dec. 31, 2008; 77 FR 20714, Apr. 6, 2012]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.362","heading":"On-shift examination.","id":"75.362","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.362","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) At least once during each shift, or more often if necessary for safety, a certified person designated by the operator shall conduct an on-shift examination of each section where anyone is assigned to work during the shift and any area where mechanized mining equipment is being installed or removed during the shift. The certified person shall check for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (a)(3) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction.\n\n(2) A person designated by the operator shall conduct an examination and record the results and the corrective actions taken to assure compliance with the respirable dust control parameters specified in the approved mine ventilation plan. In those instances when a shift change is accomplished without an interruption in production on a section, the examination shall be made anytime within 1 hour after the shift change. In those instances when there is an interruption in production during the shift change, the examination shall be made before production begins on a section. Deficiencies in dust controls shall be corrected before production begins or resumes. The examination shall include: Air quantities and velocities; water pressures and flow rates; excessive leakage in the water delivery system; water spray numbers and orientations; section ventilation and control device placement; roof bolting machine dust collector vacuum levels; scrubber air flow rate; work practices required by the ventilation plan; and any other dust suppression measures. Measurements of the air velocity and quantity, water pressure and flow rates are not required if continuous monitoring of these controls is used and indicates that the dust controls are functioning properly.\n\n(3) On-shift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(b) During each shift that coal is produced, a certified person shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (a)(3) of this section along each belt conveyor haulageway where a belt conveyor is operated. This examination may be conducted at the same time as the preshift examination of belt conveyors and belt conveyor haulageways, if the examination is conducted within 3 hours before the oncoming shift.\n\n(c) Persons conducting the on-shift examination shall determine at the following locations:\n\n(1) The volume of air in the last open crosscut of each set of entries or rooms on each section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) The volume of air on a longwall or shortwall, including areas where longwall or shortwall equipment is being installed or removed, in the intake entry or entries at the intake end of the longwall or shortwall.\n\n(3) The velocity of air at each end of the longwall or shortwall face at the locations specified in the approved ventilation plan.\n\n(4) The volume of air at the intake end of any pillar line—\n\n(i) Where a single split of air is used in the intake entry furthest from the return air course immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) Where a split system is used in the intake entries of each split immediately inby the split point.\n\n(d) (1) A qualified person shall make tests for methane—\n\n(i) At the start of each shift at each working place before electrically operated equipment is energized; and\n\n(ii) Immediately before equipment is energized, taken into, or operated in a working place; and\n\n(iii) At 20-minute intervals, or more often if required in the approved ventilation plan at specific locations, during the operation of equipment in the working place.\n\n(2) Except as provided for in paragraph (d)(3) of this section, these methane tests shall be made at the face from under permanent roof support, using extendable probes or other acceptable means. When longwall or shortwall mining systems are used, these methane tests shall be made at the shearer, the plow, or the cutting head. When mining has been stopped for more than 20 minutes, methane tests shall be conducted prior to the start up of equipment.\n\n(3) As an alternative method of compliance with paragraph (d)(2) of this section during roof bolting, methane tests may be made by sweeping an area not less than 16 feet inby the last area of permanently supported roof, using a probe or other acceptable means. This method of testing is conditioned on meeting the following requirements:\n\n(i) The roof bolting machine must be equipped with an integral automated temporary roof support (ATRS) system that meets the requirements of 30 CFR 75.209.\n\n(ii) The roof bolting machine must have a permanently mounted, MSHA-approved methane monitor which meets the maintenance and calibration requirements of 30 CFR 75.342(a)(4), the warning signal requirements of 30 CFR 75.342(b), and the automatic de-energization requirements of 30 CFR 75.342(c).\n\n(iii) The methane monitor sensor must be mounted near the inby end and within 18 inches of the longitudinal center of the ATRS support, and positioned at least 12 inches from the roof when the ATRS is fully deployed.\n\n(iv) Manual methane tests must be made at intervals not exceeding 20 minutes. The test may be made either from under permanent roof support or from the roof bolter's work position protected by the deployed ATRS.\n\n(v) Once a methane test is made at the face, all subsequent methane tests in the same area of unsupported roof must also be made at the face, from under permanent roof support, using extendable probes or other acceptable means at intervals not exceeding 20 minutes.\n\n(vi) The district manager may require that the ventilation plan include the minimum air quantity and the position and placement of ventilation controls to be maintained during roof bolting.\n\n(e) If auxiliary fans and tubing are used, they shall be inspected frequently.\n\n(f) During each shift that coal is produced and at intervals not exceeding 4 hours, tests for methane shall be made by a certified person or by an atmospheric monitoring system (AMS) in each return split of air from each working section between the last working place, or longwall or shortwall face, ventilated by that split of air and the junction of the return air split with another air split, seal, or worked-out area. If auxiliary fans and tubing are used, the tests shall be made at a location outby the auxiliary fan discharge.\n\n(g) Certification. (1) The person conducting the on-shift examination in belt haulage entries shall certify by initials, date, and time that the examination was made. The certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(2) The certified person directing the on-shift examination to assure compliance with the respirable dust control parameters specified in the approved mine ventilation plan shall:\n\n(i) Certify by initials, date, and time on a board maintained at the section load-out or similar location showing that the examination was made prior to resuming production; and\n\n(ii) Verify, by initials and date, the record of the results of the examination required under (a)(2) of this section to assure compliance with the respirable dust control parameters specified in the mine ventilation plan. The verification shall be made no later than the end of the shift for which the examination was made.\n\n(3) The mine foreman or equivalent mine official shall countersign each examination record required under (a)(2) of this section after it is verified by the certified person under (g)(2)(ii) of this section, and no later than the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The record shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(4) Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 26442, May 28, 1996, as amended at 68 FR 40138, July 7, 2003; 77 FR 20715, Apr. 6, 2012; 79 FR 24987, May 1, 2014]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-4","heading":"Automatic fire sensors and manual actuators; installation; minimum requirements.","id":"75.1107-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a)(1) Where fire suppression devices are installed on unattended underground equipment, one or more point-type sensors or equivalent shall be installed for each 50 square feet of top surface area, or fraction thereof, of such equipment, and each sensor shall be designed to activate the first suppression system and disconnect the electrical power source to the equipment protected, and, except where sprinklers are used, there shall be in addition, a manual actuator installed to operate the system. Where sprinklers are used, provision shall be made for manual application of water to the protected equipment in lieu of a manual actuator.\n\n(2) Two or more manual actuators, where practicable, shall be installed, as provided in paragraphs (a)(2) (i) and (ii) of this section, to activate fire suppression devices on attended equipment purchased on or after the effective date of this § 75.1107-4. At least one manual actuator shall be used on equipment purchased prior to the effective date of this § 75.1107-4.\n\n(i) Manual actuators installed on attended equipment regularly operated by a miner, as provided in § 75.1107-1(c)(1) shall be located at different locations on the equipment, and at least one manual actuator shall be located within easy reach of the operator's normal operating position.\n\n(ii) Manual actuators to activate fire suppression devices on attended equipment not regularly operated by a miner, as provided in § 75.1107-1(c)(2), shall be installed at different location, and at least one manual actuator shall be installed so as to be easily reached by the miner at the jobsite or by persons approaching the equipment.\n\n(b) Sensors shall, where practicable, be installed in accordance with the recommendations set forth in National Fire Code No. 72A “Local Protective Signaling Systems” (NFPA No. 72A-1967).\n\n(c) On unattended equipment the fire suppression device shall operate independently of the power to the main motor (or equivalent) so it will remain operative if the circuit breakers (or other protective device) actuates. On attended equipment powered through a trailing cable the fire suppression device shall operate independently of the electrical power provided by the cable.\n\n(d) Point-type sensors (such as thermocouple, bimetallic strip, or rate of temperature rise) located in ventilated passageways shall be installed downwind from the equipment to be protected.\n\n(e) Sensor systems shall include a device or method for determining their operative condition.\n\n[37 FR 15301, July 29, 1972]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4608603","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}