{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4608577","name":"Jims Branch No 2","status":"Abandoned and Sealed","status_date":"2012-08-28","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Wyoming","nearest_town":"New Richmond","operator_id":"P23225","operator_name":"Chief Mining Inc","controller_id":"C13525","controller_name":"Kenneth R  Calloway","district":"C04","office":"Beckley District","employees":0,"latitude":37.581388,"longitude":-81.479166},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":2664},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4608577","name":"Jims Branch No 2"},"operator":{"type":"operator","id":"P23225","name":"Chief Mining Inc"},"controller":{"type":"controller","id":"C13525","name":"Kenneth R  Calloway"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15297","name":"Calloway Kevin B"},"object":{"type":"mine","id":"4608577","name":"Jims Branch No 2"},"validFrom":"1995-08-01","validTo":"2003-11-11","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608577|C15297|1995-08-01|2003-11-11"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23225","name":"Chief Mining Inc"},"object":{"type":"mine","id":"4608577","name":"Jims Branch No 2"},"validFrom":"1996-07-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608577|P23225|1996-07-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15297","name":"Calloway Kevin B"},"object":{"type":"operator","id":"P23225","name":"Chief Mining Inc"},"validFrom":"1996-07-01","validTo":"2003-11-11","current":false,"derived":true,"evidenceMineId":"4608577","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608577|P23225|1996-07-01|C15297|1995-08-01|95199"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13525","name":"Kenneth R  Calloway"},"object":{"type":"mine","id":"4608577","name":"Jims Branch No 2"},"validFrom":"2003-11-12","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608577|C13525|2003-11-12|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13525","name":"Kenneth R  Calloway"},"object":{"type":"operator","id":"P23225","name":"Chief Mining Inc"},"validFrom":"2003-11-12","validTo":null,"current":true,"derived":true,"evidenceMineId":"4608577","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608577|P23225|1996-07-01|C13525|2003-11-12|90231"}}],"coverage":{"historyRecords":2,"edgeCount":5,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":18,"firstDate":"2000-04-10","lastDate":"2010-06-11","metrics":{"daysLost":463,"injuries":14,"fatalities":0,"recentRows":0,"restrictedDays":36,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"85463","DOCUMENT_NO":"220101680015","ACCIDENT_DT":"06/11/2010","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"30","NARRATIVE":"While making a belt splice on the #1 Belt line, the com-a-longs slipped allowing the belt clamps to strike the lower right leg!","sourceDate":"2010-06-11"},{"SOURCE_ROW_NUMBER":"236119","DOCUMENT_NO":"220100400002","ACCIDENT_DT":"01/29/2010","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"20","NARRATIVE":"When switching seats on shuttle car to change direction, he had pain in his back!","sourceDate":"2010-01-29"},{"SOURCE_ROW_NUMBER":"150071","DOCUMENT_NO":"220082890039","ACCIDENT_DT":"10/02/2008","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"44","NARRATIVE":"While operating the S & S 482 scoop, the victim placed his arm outside the operator's compartment. While holding on to the stop block, the machine was turned fully to the right and the machine mashed the end of his finger.","sourceDate":"2008-10-02"},{"SOURCE_ROW_NUMBER":"76950","DOCUMENT_NO":"220071370052","ACCIDENT_DT":"05/04/2007","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"11","NARRATIVE":"While shoveling belt, the employee hit his hand aganst a belt splice causing a cut.","sourceDate":"2007-05-04"},{"SOURCE_ROW_NUMBER":"162942","DOCUMENT_NO":"220071370051","ACCIDENT_DT":"04/20/2007","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Belt cleaner, Picker","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The Employee was not following instructions on cleaning belt. After repeated warnings, he was teminated. The following week the company was notified that the employee strained his knee while getting on the personnel 3 wheeler to go outside.","sourceDate":"2007-04-20"},{"SOURCE_ROW_NUMBER":"76949","DOCUMENT_NO":"220062960063","ACCIDENT_DT":"10/04/2006","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Greaser, Grease man, Oiler, Lube man, Dragline oiler","NO_INJURIES":"1","DAYS_LOST":"86","NARRATIVE":"Employee was riding on a boss hoss mantrip. To avoid the possibility of getting wet, he raised up off the mantrip striking the roof and getting pushed into the battery compartment.","sourceDate":"2006-10-04"},{"SOURCE_ROW_NUMBER":"162941","DOCUMENT_NO":"220062000050","ACCIDENT_DT":"07/11/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"39","NARRATIVE":"Employee stated that while operating a scoop, a piece of draw rock measuring 2\" x 12\" x 14\" fell approximately 6\" and struck employee on the cap light. Roof bolts in this area were installed according to the approved roof control plan.","sourceDate":"2006-07-11"},{"SOURCE_ROW_NUMBER":"205936","DOCUMENT_NO":"220050100106","ACCIDENT_DT":"12/31/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"50","NARRATIVE":"Employee was positioned out by the continuous miner (x-cut out by block being mined) when a piece of draw rock fell between roof bolts and rib striking employee.","sourceDate":"2004-12-31"},{"SOURCE_ROW_NUMBER":"3851","DOCUMENT_NO":"220033110026","ACCIDENT_DT":"10/30/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"PICKED UP 5 GAL OIL CAN & THREW WITH LEFT HAND.","sourceDate":"2003-10-30"},{"SOURCE_ROW_NUMBER":"270447","DOCUMENT_NO":"220030970031","ACCIDENT_DT":"04/01/2003","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"ROOF FALL 70' LONG X 20' WIDE X 5' HIGH BOLTED WITH 36\" RESIN BOLTS AREA SPOT BOLTED WITH 48\" RESIN BOLTS.","sourceDate":"2003-04-01"},{"SOURCE_ROW_NUMBER":"3850","DOCUMENT_NO":"220030830152","ACCIDENT_DT":"03/12/2003","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"NO VALUE FOUND","ACCIDENT_TYPE":"No Value Found","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"WHILE ATTEMPTING TO REMOVE A CRIB BLOCK FROM UNDERNEATH A SHUTTLE CAR, HE GOT HIS FINGERS PINCHED BETWEEN THE SHUTTLE CAR AND CRIB BLOCK.","sourceDate":"2003-03-12"},{"SOURCE_ROW_NUMBER":"29560","DOCUMENT_NO":"220030210087","ACCIDENT_DT":"01/14/2003","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"ROOF FALL AT 1 BREAK INBY SPAD #1899. 25' WIDE, 6' HIGH. AREA WAS CRIBBED. AREA WAS CRIBBED AND TIMBERED OFF 25'+ LONG.","sourceDate":"2003-01-14"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2012-08-28","lastDate":"2012-08-28","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":626,"firstDate":"2000-02-06","lastDate":"2012-03-22","metrics":{"ss":208,"delinquent":626,"recentRows":0,"paidPenalty":216339.5,"proposedPenalty":287614,"currentAssessment":216339.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1809818","VIOLATION_NO":"8134923","ISSUE_DT":"03/22/2012","CFR_STANDARD_CD":"75.333(d)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-03-22"},{"SOURCE_ROW_NUMBER":"1809817","VIOLATION_NO":"8134922","ISSUE_DT":"03/22/2012","CFR_STANDARD_CD":"77.701","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-03-22"},{"SOURCE_ROW_NUMBER":"1809816","VIOLATION_NO":"8134921","ISSUE_DT":"03/19/2012","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-03-19"},{"SOURCE_ROW_NUMBER":"1809815","VIOLATION_NO":"8134920","ISSUE_DT":"03/19/2012","CFR_STANDARD_CD":"75.360(g)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-03-19"},{"SOURCE_ROW_NUMBER":"1815543","VIOLATION_NO":"8144836","ISSUE_DT":"12/20/2011","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"162.00","CURRENT_ASSESSMENT_AMT":"162.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-12-20"},{"SOURCE_ROW_NUMBER":"1815542","VIOLATION_NO":"8144835","ISSUE_DT":"12/20/2011","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-12-20"},{"SOURCE_ROW_NUMBER":"1815541","VIOLATION_NO":"8144834","ISSUE_DT":"12/20/2011","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"162.00","CURRENT_ASSESSMENT_AMT":"162.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-12-20"},{"SOURCE_ROW_NUMBER":"1815540","VIOLATION_NO":"8144833","ISSUE_DT":"12/20/2011","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"162.00","CURRENT_ASSESSMENT_AMT":"162.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-12-20"},{"SOURCE_ROW_NUMBER":"1815539","VIOLATION_NO":"8144832","ISSUE_DT":"12/20/2011","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"162.00","CURRENT_ASSESSMENT_AMT":"162.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-12-20"},{"SOURCE_ROW_NUMBER":"1815538","VIOLATION_NO":"8144831","ISSUE_DT":"12/19/2011","CFR_STANDARD_CD":"75.1731(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-12-19"},{"SOURCE_ROW_NUMBER":"1815537","VIOLATION_NO":"8144830","ISSUE_DT":"12/19/2011","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"285.00","CURRENT_ASSESSMENT_AMT":"285.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-12-19"},{"SOURCE_ROW_NUMBER":"1815536","VIOLATION_NO":"8144829","ISSUE_DT":"12/19/2011","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1412.00","CURRENT_ASSESSMENT_AMT":"500.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-12-19"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":54,"firstDate":"2011-11-28","lastDate":"2013-11-26","metrics":{"appeals":0,"decisions":54,"recentRows":0,"decisionPenalty":90650.5,"originalPenalty":162626},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"320350","VIOLATION_NO":"8144822","DOCKET_NO":"WEVA 2012-799","DECISION_DT":"11/26/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1203.00","DECISION_PENALTY_AMT":"962.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2013-11-26"},{"SOURCE_ROW_NUMBER":"320180","VIOLATION_NO":"8144829","DOCKET_NO":"WEVA 2012-799","DECISION_DT":"11/26/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1412.00","DECISION_PENALTY_AMT":"500.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2013-11-26"},{"SOURCE_ROW_NUMBER":"320179","VIOLATION_NO":"8144825","DOCKET_NO":"WEVA 2012-799","DECISION_DT":"11/26/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"112.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2013-11-26"},{"SOURCE_ROW_NUMBER":"319964","VIOLATION_NO":"8144830","DOCKET_NO":"WEVA 2012-799","DECISION_DT":"11/26/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"285.00","DECISION_PENALTY_AMT":"285.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2013-11-26"},{"SOURCE_ROW_NUMBER":"319963","VIOLATION_NO":"8144823","DOCKET_NO":"WEVA 2012-799","DECISION_DT":"11/26/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1203.00","DECISION_PENALTY_AMT":"270.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2013-11-26"},{"SOURCE_ROW_NUMBER":"319962","VIOLATION_NO":"8138657","DOCKET_NO":"WEVA 2012-799","DECISION_DT":"11/26/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"243.00","DECISION_PENALTY_AMT":"112.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2013-11-26"},{"SOURCE_ROW_NUMBER":"319922","VIOLATION_NO":"8144824","DOCKET_NO":"WEVA 2012-799","DECISION_DT":"11/26/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"285.00","DECISION_PENALTY_AMT":"285.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2013-11-26"},{"SOURCE_ROW_NUMBER":"83782","VIOLATION_NO":"8144819","DOCKET_NO":"WEVA 2012-799","DECISION_DT":"11/26/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"243.00","DECISION_PENALTY_AMT":"243.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2013-11-26"},{"SOURCE_ROW_NUMBER":"83781","VIOLATION_NO":"8144818","DOCKET_NO":"WEVA 2012-799","DECISION_DT":"11/26/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"468.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2013-11-26"},{"SOURCE_ROW_NUMBER":"88645","VIOLATION_NO":"8144827","DOCKET_NO":"WEVA 2012-1477","DECISION_DT":"05/30/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"25800.00","DECISION_PENALTY_AMT":"20000.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2013-05-30"},{"SOURCE_ROW_NUMBER":"283057","VIOLATION_NO":"8104400","DOCKET_NO":"WEVA 2010-1700","DECISION_DT":"03/29/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"285.00","DECISION_PENALTY_AMT":"175.00","JUDGE_FIRST_NAME":"Jeffrey","JUDGE_LAST_NAME":"Tureck","sourceDate":"2013-03-29"},{"SOURCE_ROW_NUMBER":"282972","VIOLATION_NO":"8104407","DOCKET_NO":"WEVA 2010-1700","DECISION_DT":"03/29/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3405.00","DECISION_PENALTY_AMT":"2140.00","JUDGE_FIRST_NAME":"Jeffrey","JUDGE_LAST_NAME":"Tureck","sourceDate":"2013-03-29"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":874,"firstDate":"2000-01-24","lastDate":"2012-01-27","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":105,"validSamples":769,"maxConcentration":6.115,"concentrationTotal":380.385},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1516400","CASS_NUM":"51139479","SMP_TAKEN_DT":"1/27/2012","CONC":".214","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-01-27"},{"SOURCE_ROW_NUMBER":"131133","CASS_NUM":"51139697","SMP_TAKEN_DT":"1/25/2012","CONC":".228","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-01-25"},{"SOURCE_ROW_NUMBER":"1245111","CASS_NUM":"51139475","SMP_TAKEN_DT":"1/20/2012","CONC":".36","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-01-20"},{"SOURCE_ROW_NUMBER":"871210","CASS_NUM":"51139703","SMP_TAKEN_DT":"1/19/2012","CONC":".472","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-01-19"},{"SOURCE_ROW_NUMBER":"975716","CASS_NUM":"51139466","SMP_TAKEN_DT":"1/18/2012","CONC":".281","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-01-18"},{"SOURCE_ROW_NUMBER":"1346174","CASS_NUM":"57910063","SMP_TAKEN_DT":"12/27/2011","CONC":".475","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-12-27"},{"SOURCE_ROW_NUMBER":"933480","CASS_NUM":"57910079","SMP_TAKEN_DT":"12/27/2011","CONC":".37","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ELECTRICIAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-12-27"},{"SOURCE_ROW_NUMBER":"834213","CASS_NUM":"57909869","SMP_TAKEN_DT":"12/27/2011","CONC":".91","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-12-27"},{"SOURCE_ROW_NUMBER":"771137","CASS_NUM":"57909886","SMP_TAKEN_DT":"12/27/2011","CONC":"2.572","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SECTION FOREMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-12-27"},{"SOURCE_ROW_NUMBER":"702869","CASS_NUM":"57910092","SMP_TAKEN_DT":"12/27/2011","CONC":".092","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-12-27"},{"SOURCE_ROW_NUMBER":"352664","CASS_NUM":"57909868","SMP_TAKEN_DT":"12/27/2011","CONC":".241","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-12-27"},{"SOURCE_ROW_NUMBER":"411016","CASS_NUM":"51140454","SMP_TAKEN_DT":"12/12/2011","CONC":".303","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-12-12"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":9,"firstDate":"2000-10-10","lastDate":"2008-03-28","metrics":{"linkedIssuances":9},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":54,"firstDate":"2010-06-17","lastDate":"2011-12-19","metrics":{"decisions":54,"ssChanged":3,"recentRows":0,"decisionPenalty":90650.5,"proposedPenalty":162626},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"423490","CITATION_NO":"8144830","CITATION_ISSUE_DT":"12/19/2011","DOCKET_NO":"WEVA 2012-799","DECISION_DT":"11/26/2013","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"285.00","DECISION_PENALTY_AMT":"285.00","sourceDate":"2011-12-19"},{"SOURCE_ROW_NUMBER":"366347","CITATION_NO":"8144829","CITATION_ISSUE_DT":"12/19/2011","DOCKET_NO":"WEVA 2012-799","DECISION_DT":"11/26/2013","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1412.00","DECISION_PENALTY_AMT":"500.00","sourceDate":"2011-12-19"},{"SOURCE_ROW_NUMBER":"309146","CITATION_NO":"8138657","CITATION_ISSUE_DT":"12/19/2011","DOCKET_NO":"WEVA 2012-799","DECISION_DT":"11/26/2013","CFR_STANDARD_CODE":"75.1714-3(d)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"243.00","DECISION_PENALTY_AMT":"112.00","sourceDate":"2011-12-19"},{"SOURCE_ROW_NUMBER":"258964","CITATION_NO":"8144822","CITATION_ISSUE_DT":"12/19/2011","DOCKET_NO":"WEVA 2012-799","DECISION_DT":"11/26/2013","CFR_STANDARD_CODE":"75.1714-4(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1203.00","DECISION_PENALTY_AMT":"962.00","sourceDate":"2011-12-19"},{"SOURCE_ROW_NUMBER":"253261","CITATION_NO":"8144827","CITATION_ISSUE_DT":"12/19/2011","DOCKET_NO":"WEVA 2012-1477","DECISION_DT":"05/30/2013","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"25800.00","DECISION_PENALTY_AMT":"20000.00","sourceDate":"2011-12-19"},{"SOURCE_ROW_NUMBER":"145431","CITATION_NO":"8144823","CITATION_ISSUE_DT":"12/19/2011","DOCKET_NO":"WEVA 2012-799","DECISION_DT":"11/26/2013","CFR_STANDARD_CODE":"75.1714-3(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1203.00","DECISION_PENALTY_AMT":"270.00","sourceDate":"2011-12-19"},{"SOURCE_ROW_NUMBER":"145430","CITATION_NO":"8144824","CITATION_ISSUE_DT":"12/19/2011","DOCKET_NO":"WEVA 2012-799","DECISION_DT":"11/26/2013","CFR_STANDARD_CODE":"75.1101-1(b)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"285.00","DECISION_PENALTY_AMT":"285.00","sourceDate":"2011-12-19"},{"SOURCE_ROW_NUMBER":"29813","CITATION_NO":"8144825","CITATION_ISSUE_DT":"12/19/2011","DOCKET_NO":"WEVA 2012-799","DECISION_DT":"11/26/2013","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"112.00","sourceDate":"2011-12-19"},{"SOURCE_ROW_NUMBER":"195777","CITATION_NO":"8144819","CITATION_ISSUE_DT":"12/14/2011","DOCKET_NO":"WEVA 2012-799","DECISION_DT":"11/26/2013","CFR_STANDARD_CODE":"75.1722(c)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"243.00","DECISION_PENALTY_AMT":"243.00","sourceDate":"2011-12-14"},{"SOURCE_ROW_NUMBER":"86270","CITATION_NO":"8144818","CITATION_ISSUE_DT":"12/14/2011","DOCKET_NO":"WEVA 2012-799","DECISION_DT":"11/26/2013","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"468.00","sourceDate":"2011-12-14"},{"SOURCE_ROW_NUMBER":"138204","CITATION_NO":"8136817","CITATION_ISSUE_DT":"06/22/2011","DOCKET_NO":"WEVA 2011-2386","DECISION_DT":"09/06/2012","CFR_STANDARD_CODE":"75.1100-3","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"362.00","DECISION_PENALTY_AMT":"362.00","sourceDate":"2011-06-22"},{"SOURCE_ROW_NUMBER":"87149","CITATION_NO":"8136816","CITATION_ISSUE_DT":"06/22/2011","DOCKET_NO":"WEVA 2011-2386","DECISION_DT":"09/06/2012","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"362.00","DECISION_PENALTY_AMT":"166.00","sourceDate":"2011-06-22"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":86,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":17,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"1996-07-01","lastDate":"1996-07-01","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":122,"firstDate":"2000-01-03","lastDate":"2012-03-19","metrics":{"inspectors":166,"recentRows":0,"onSiteHours":3756.5,"inspectionHours":5296.75,"inspectionSamples":328},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1138593","EVENT_NO":"6291549","INSPECTION_BEGIN_DT":"03/19/2012","INSPECTION_END_DT":"03/27/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"19.5","SUM_TOTAL_ON_SITE_HOURS":"12","sourceDate":"2012-03-19"},{"SOURCE_ROW_NUMBER":"742097","EVENT_NO":"6292841","INSPECTION_BEGIN_DT":"01/24/2012","INSPECTION_END_DT":"01/24/2012","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2012-01-24"},{"SOURCE_ROW_NUMBER":"555559","EVENT_NO":"6292835","INSPECTION_BEGIN_DT":"12/13/2011","INSPECTION_END_DT":"12/28/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"73.75","SUM_TOTAL_ON_SITE_HOURS":"57.25","sourceDate":"2011-12-13"},{"SOURCE_ROW_NUMBER":"595315","EVENT_NO":"6295652","INSPECTION_BEGIN_DT":"09/20/2011","INSPECTION_END_DT":"09/20/2011","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2011-09-20"},{"SOURCE_ROW_NUMBER":"76684","EVENT_NO":"6294957","INSPECTION_BEGIN_DT":"08/03/2011","INSPECTION_END_DT":"09/12/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"104.25","SUM_TOTAL_ON_SITE_HOURS":"82.25","sourceDate":"2011-08-03"},{"SOURCE_ROW_NUMBER":"1035597","EVENT_NO":"6292533","INSPECTION_BEGIN_DT":"07/19/2011","INSPECTION_END_DT":"08/23/2011","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"5.75","sourceDate":"2011-07-19"},{"SOURCE_ROW_NUMBER":"380318","EVENT_NO":"6294952","INSPECTION_BEGIN_DT":"06/15/2011","INSPECTION_END_DT":"06/29/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"77.75","SUM_TOTAL_ON_SITE_HOURS":"66.75","sourceDate":"2011-06-15"},{"SOURCE_ROW_NUMBER":"450790","EVENT_NO":"6292186","INSPECTION_BEGIN_DT":"05/25/2011","INSPECTION_END_DT":"05/25/2011","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2011-05-25"},{"SOURCE_ROW_NUMBER":"945209","EVENT_NO":"6292715","INSPECTION_BEGIN_DT":"04/12/2011","INSPECTION_END_DT":"04/29/2011","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.75","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2011-04-12"},{"SOURCE_ROW_NUMBER":"320221","EVENT_NO":"4119749","INSPECTION_BEGIN_DT":"03/11/2011","INSPECTION_END_DT":"03/31/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"111.5","SUM_TOTAL_ON_SITE_HOURS":"59","sourceDate":"2011-03-11"},{"SOURCE_ROW_NUMBER":"879469","EVENT_NO":"6292708","INSPECTION_BEGIN_DT":"02/22/2011","INSPECTION_END_DT":"04/06/2011","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.25","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2011-02-22"},{"SOURCE_ROW_NUMBER":"510920","EVENT_NO":"6289121","INSPECTION_BEGIN_DT":"01/04/2011","INSPECTION_END_DT":"01/07/2011","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"4.25","sourceDate":"2011-01-04"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":52,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2011-Q2":{"hours":11035,"employees":22,"production":20369},"2011-Q1":{"hours":9797,"employees":13,"production":17455},"2010-Q4":{"hours":7540,"employees":16,"production":13863},"2010-Q3":{"hours":10870,"employees":23,"production":11027},"2010-Q2":{"hours":16440,"employees":30,"production":20719},"2010-Q1":{"hours":14026,"employees":27,"production":26903},"2009-Q4":{"hours":7549,"employees":23,"production":25260},"2009-Q3":{"hours":10648,"employees":21,"production":22046},"2009-Q2":{"hours":7670,"employees":18,"production":16047},"2009-Q1":{"hours":14746,"employees":32,"production":23908},"2008-Q4":{"hours":16784,"employees":32,"production":24277},"2008-Q3":{"hours":13650,"employees":32,"production":26795}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":14,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002":{"hours":47793,"employees":26,"production":160292},"2003":{"hours":62941,"employees":23,"production":162626},"2004":{"hours":48059,"employees":31,"production":168806},"2005":{"hours":45625,"employees":32,"production":92487},"2006":{"hours":54696,"employees":35,"production":106128},"2007":{"hours":60047,"employees":33,"production":123737},"2008":{"hours":67338,"employees":32,"production":127762},"2009":{"hours":40613,"employees":24,"production":87261},"2010":{"hours":48876,"employees":24,"production":72512},"2011":{"hours":20832,"employees":18,"production":37824}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":43,"firstDate":"2000-02-29","lastDate":"2011-09-06","metrics":{"recentRows":0,"doseOver100":0,"actDoseTotal":1899,"pelDoseTotal":1242},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"238805","EVENT_NO":"6294957","SURVEY_DATE":"09/06/2011","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"34","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2011-09-06"},{"SOURCE_ROW_NUMBER":"238804","EVENT_NO":"6294957","SURVEY_DATE":"09/06/2011","OCCUPATION_CD_DESC":"ROOF BOLTER HELPER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"043","ACT_DOSE_85":"38","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2011-09-06"},{"SOURCE_ROW_NUMBER":"238803","EVENT_NO":"6294957","SURVEY_DATE":"09/06/2011","OCCUPATION_CD_DESC":"CONTINUOUS MINER HELPER","MACHINE_CD":"06","MANUFACTURER_CD":"033","ACT_DOSE_85":"17","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2011-09-06"},{"SOURCE_ROW_NUMBER":"238802","EVENT_NO":"6294957","SURVEY_DATE":"09/06/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"043","ACT_DOSE_85":"50","PEL_DOSE_90":"30","SURVEY_TYPE":"I","sourceDate":"2011-09-06"},{"SOURCE_ROW_NUMBER":"238801","EVENT_NO":"6294957","SURVEY_DATE":"09/06/2011","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"033","ACT_DOSE_85":"24","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2011-09-06"},{"SOURCE_ROW_NUMBER":"238800","EVENT_NO":"6287211","SURVEY_DATE":"01/27/2010","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"33","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2010-01-27"},{"SOURCE_ROW_NUMBER":"238799","EVENT_NO":"6287211","SURVEY_DATE":"01/27/2010","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"42","PEL_DOSE_90":"18","SURVEY_TYPE":"I","sourceDate":"2010-01-27"},{"SOURCE_ROW_NUMBER":"238798","EVENT_NO":"6287211","SURVEY_DATE":"01/27/2010","OCCUPATION_CD_DESC":"TRACTOR OPERATOR/MOTORMAN","MACHINE_CD":"38","MANUFACTURER_CD":"102","ACT_DOSE_85":"30","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2010-01-27"},{"SOURCE_ROW_NUMBER":"238797","EVENT_NO":"6287211","SURVEY_DATE":"01/27/2010","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"043","ACT_DOSE_85":"64","PEL_DOSE_90":"39","SURVEY_TYPE":"I","sourceDate":"2010-01-27"},{"SOURCE_ROW_NUMBER":"238796","EVENT_NO":"6287211","SURVEY_DATE":"01/27/2010","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"033","ACT_DOSE_85":"47","PEL_DOSE_90":"33","SURVEY_TYPE":"I","sourceDate":"2010-01-27"},{"SOURCE_ROW_NUMBER":"238795","EVENT_NO":"4121942","SURVEY_DATE":"09/23/2009","OCCUPATION_CD_DESC":"TRACTOR OPERATOR/MOTORMAN","MACHINE_CD":"38","MANUFACTURER_CD":"102","ACT_DOSE_85":"16","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2009-09-23"},{"SOURCE_ROW_NUMBER":"238794","EVENT_NO":"4121942","SURVEY_DATE":"09/23/2009","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"42","PEL_DOSE_90":"30","SURVEY_TYPE":"I","sourceDate":"2009-09-23"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":57,"firstDate":"2000-02-16","lastDate":"2011-12-27","metrics":{"recentRows":0,"voidSamples":1,"maxQuartzPct":36.4,"validSamples":56,"quartzPctTotal":625.1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"154977","CASSETTE_NO":"57909869","SAMPLE_DT":"12/27/2011","QUARTZ_PCT":"00.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-12-27"},{"SOURCE_ROW_NUMBER":"115151","CASSETTE_NO":"57887702","SAMPLE_DT":"08/11/2011","QUARTZ_PCT":"08.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-08-11"},{"SOURCE_ROW_NUMBER":"110679","CASSETTE_NO":"57864426","SAMPLE_DT":"03/24/2011","QUARTZ_PCT":"03.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-03-24"},{"SOURCE_ROW_NUMBER":"85537","CASSETTE_NO":"57864399","SAMPLE_DT":"03/24/2011","QUARTZ_PCT":"11.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-03-24"},{"SOURCE_ROW_NUMBER":"42452","CASSETTE_NO":"57853840","SAMPLE_DT":"12/28/2010","QUARTZ_PCT":"05.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-12-28"},{"SOURCE_ROW_NUMBER":"95649","CASSETTE_NO":"57829002","SAMPLE_DT":"02/04/2010","QUARTZ_PCT":"03.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-02-04"},{"SOURCE_ROW_NUMBER":"52661","CASSETTE_NO":"57817025","SAMPLE_DT":"11/19/2009","QUARTZ_PCT":"01.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-11-19"},{"SOURCE_ROW_NUMBER":"111496","CASSETTE_NO":"57817290","SAMPLE_DT":"09/22/2009","QUARTZ_PCT":"01.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-09-22"},{"SOURCE_ROW_NUMBER":"162783","CASSETTE_NO":"57691515","SAMPLE_DT":"05/18/2009","QUARTZ_PCT":"12.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-05-18"},{"SOURCE_ROW_NUMBER":"98948","CASSETTE_NO":"57691419","SAMPLE_DT":"03/18/2009","QUARTZ_PCT":"10.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-03-18"},{"SOURCE_ROW_NUMBER":"55642","CASSETTE_NO":"57691593","SAMPLE_DT":"03/18/2009","QUARTZ_PCT":"14.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-03-18"},{"SOURCE_ROW_NUMBER":"34613","CASSETTE_NO":"57737997","SAMPLE_DT":"12/12/2008","QUARTZ_PCT":"03.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-12-12"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":634,"firstDate":"2000-02-06","lastDate":"2012-03-22","metrics":{"ss":208,"amountDue":216339.5,"contested":11,"amountPaid":216339.5,"recentRows":0,"section104d":10,"unterminated":2,"proposedPenalty":287614},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2736625","VIOLATION_NO":"8134923","VIOLATION_ISSUE_DT":"03/22/2012","SIG_SUB":"N","PART_SECTION":"75.333(d)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/22/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-03-22"},{"SOURCE_ROW_NUMBER":"2736624","VIOLATION_NO":"8134922","VIOLATION_ISSUE_DT":"03/22/2012","SIG_SUB":"N","PART_SECTION":"77.701","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"NoNegligence","TERMINATION_DT":"03/22/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-03-22"},{"SOURCE_ROW_NUMBER":"2736623","VIOLATION_NO":"8134921","VIOLATION_ISSUE_DT":"03/19/2012","SIG_SUB":"N","PART_SECTION":"75.1100-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/19/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-03-19"},{"SOURCE_ROW_NUMBER":"2736622","VIOLATION_NO":"8134920","VIOLATION_ISSUE_DT":"03/19/2012","SIG_SUB":"N","PART_SECTION":"75.360(g)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/22/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-03-19"},{"SOURCE_ROW_NUMBER":"2737114","VIOLATION_NO":"8144836","VIOLATION_ISSUE_DT":"12/20/2011","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/27/2011","PROPOSED_PENALTY":"162","AMOUNT_DUE":"162","AMOUNT_PAID":"162","CONTESTED_IND":"N","sourceDate":"2011-12-20"},{"SOURCE_ROW_NUMBER":"2737113","VIOLATION_NO":"8144835","VIOLATION_ISSUE_DT":"12/20/2011","SIG_SUB":"N","PART_SECTION":"75.1100-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/20/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-12-20"},{"SOURCE_ROW_NUMBER":"2737112","VIOLATION_NO":"8144834","VIOLATION_ISSUE_DT":"12/20/2011","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/20/2011","PROPOSED_PENALTY":"162","AMOUNT_DUE":"162","AMOUNT_PAID":"162","CONTESTED_IND":"N","sourceDate":"2011-12-20"},{"SOURCE_ROW_NUMBER":"2737111","VIOLATION_NO":"8144833","VIOLATION_ISSUE_DT":"12/20/2011","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/20/2011","PROPOSED_PENALTY":"162","AMOUNT_DUE":"162","AMOUNT_PAID":"162","CONTESTED_IND":"N","sourceDate":"2011-12-20"},{"SOURCE_ROW_NUMBER":"2737110","VIOLATION_NO":"8144832","VIOLATION_ISSUE_DT":"12/20/2011","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/20/2011","PROPOSED_PENALTY":"162","AMOUNT_DUE":"162","AMOUNT_PAID":"162","CONTESTED_IND":"N","sourceDate":"2011-12-20"},{"SOURCE_ROW_NUMBER":"2737109","VIOLATION_NO":"8144831","VIOLATION_ISSUE_DT":"12/19/2011","SIG_SUB":"N","PART_SECTION":"75.1731(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/27/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-12-19"},{"SOURCE_ROW_NUMBER":"2737108","VIOLATION_NO":"8144830","VIOLATION_ISSUE_DT":"12/19/2011","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"10","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/27/2011","PROPOSED_PENALTY":"285","AMOUNT_DUE":"285","AMOUNT_PAID":"285","CONTESTED_IND":"N","sourceDate":"2011-12-19"},{"SOURCE_ROW_NUMBER":"2737107","VIOLATION_NO":"8144829","VIOLATION_ISSUE_DT":"12/19/2011","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"10","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/27/2011","PROPOSED_PENALTY":"1412","AMOUNT_DUE":"500","AMOUNT_PAID":"500","CONTESTED_IND":"N","sourceDate":"2011-12-19"}]}],"safety":{"href":"/api/v1/mines/4608577/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4608577/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","heading":"Grounding metallic frames, casings, and other enclosures of electric equipment.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-H/section-77.701","part":"77","subchapter":"O","subpart":"H","id":"77.701","citation":"30 CFR 77.701","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-3","heading":"Condition and examination of firefighting equipment.","id":"75.1100-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"All firefighting equipment shall be maintained in a usable and operative condition. Chemical extinguishers shall be examined every 6 months and the date of the examination shall be written on a permanent tag attached to the extinguisher.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.360","heading":"Preshift examination at fixed intervals.","id":"75.360","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.360","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) Except as provided in paragraph (a)(2) of this section, a certified person designated by the operator must make a preshift examination within 3 hours preceding the beginning of any 8-hour interval during which any person is scheduled to work or travel underground. No person other than certified examiners may enter or remain in any underground area unless a preshift examination has been completed for the established 8-hour interval. The operator must establish 8-hour intervals of time subject to the required preshift examinations.\n\n(2) Preshift examinations of areas where pumpers are scheduled to work or travel shall not be required prior to the pumper entering the areas if the pumper is a certified person and the pumper conducts an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, tests for methane and oxygen deficiency, and determines if the air is moving in its proper direction in the area where the pumper works or travels. The examination of the area must be completed before the pumper performs any other work. A record of all hazardous conditions and violations of the mandatory health or safety standards found by the pumper shall be made and retained in accordance with § 75.363 of this part.\n\n(b) The person conducting the preshift examination shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction at the following locations:\n\n(1) Roadways, travelways and track haulageways where persons are scheduled, prior to the beginning of the preshift examination, to work or travel during the oncoming shift.\n\n(2) Belt conveyors that will be used to transport persons during the oncoming shift and the entries in which these belt conveyors are located.\n\n(3) Working sections and areas where mechanized mining equipment is being installed or removed, if anyone is scheduled to work on the section or in the area during the oncoming shift. The scope of the examination shall include the working places, approaches to worked-out areas and ventilation controls on these sections and in these areas, and the examination shall include tests of the roof, face and rib conditions on these sections and in these areas.\n\n(4) Approaches to worked-out areas along intake air courses and at the entries used to carry air into worked-out areas if the intake air passing the approaches is used to ventilate working sections where anyone is scheduled to work during the oncoming shift. The examination of the approaches to the worked-out areas shall be made in the intake air course immediately inby and outby each entry used to carry air into the worked-out area. An examination of the entries used to carry air into the worked-out areas shall be conducted at a point immediately inby the intersection of each entry with the intake air course.\n\n(5) Seals along intake air courses where intake air passes by a seal to ventilate working sections where anyone is scheduled to work during the oncoming shift.\n\n(6)(i) Entries and rooms developed after November 15, 1992, and developed more than 2 crosscuts off an intake air course without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift; and,\n\n(ii) Entries and rooms developed after November 15, 1992, and driven more than 20 feet off an intake air course without a crosscut and without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift.\n\n(7) Areas where trolley wires or trolley feeder wires are to be or will remain energized during the oncoming shift.\n\n(8) High spots along intake air courses where methane is likely to accumulate, if equipment will be operated in the area during the shift.\n\n(9) Underground electrical installations referred to in § 75.340(a), except those pumps listed in § 75.340 (b)(2) through (b)(6), and areas where compressors subject to § 75.344 are installed if the electrical installation or compressor is or will be energized during the shift.\n\n(10) Other areas where work or travel during the oncoming shift is scheduled prior to the beginning of the preshift examination.\n\n(11) Preshift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) The person conducting the preshift examination shall determine the volume of air entering each of the following areas if anyone is scheduled to work in the areas during the oncoming shift:\n\n(1) In the last open crosscut of each set of entries or rooms on each working section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) On each longwall or shortwall in the intake entry or entries at the intake end of the longwall or shortwall face immediately outby the face and the velocity of air at each end of the face at the locations specified in the approved ventilation plan.\n\n(3) At the intake end of any pillar line—\n\n(i) If a single split of air is used, in the intake entry furthest from the return air course, immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) If a split system is used, in the intake entries of each split immediately inby the split point.\n\n(d) The person conducting the preshift examination shall check the refuge alternative for damage, the integrity of the tamper-evident seal and the mechanisms required to deploy the refuge alternative, and the ready availability of compressed oxygen and air.\n\n(e) The district manager may require the operator to examine other areas of the mine or examine for other hazards and violations of other mandatory health or safety standards found during the preshift examination.\n\n(f) Certification. At each working place examined, the person doing the preshift examination shall certify by initials, date, and the time, that the examination was made. In areas required to be examined outby a working section, the certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(g) Recordkeeping. A record of the results of each preshift examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards and their locations found by the examiner during each examination, and of the results and locations of air and methane measurements, shall be made on the surface before any persons, other than certified persons conducting examinations required by this subpart, enter any underground area of the mine. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the certified person who made the examination or by a person designated by the operator. If the record is made by someone other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. A record shall also be made by a certified person of the action taken to correct hazardous conditions and violations of mandatory health or safety standards found during the preshift examination. All preshift and corrective action records shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(h) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 62 FR 35085, June 30, 1997; 64 FR 45170, Aug. 19, 1999; 73 FR 80697, Dec. 31, 2008; 77 FR 20714, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":4},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1731","heading":"Maintenance of belt conveyors and belt conveyor entries.","id":"75.1731","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1731","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Damaged rollers, or other damaged belt conveyor components, which pose a fire hazard must be immediately repaired or replaced. All other damaged rollers, or other damaged belt conveyor components, must be repaired or replaced.\n\n(b) Conveyor belts must be properly aligned to prevent the moving belt from rubbing against the structure or components.\n\n(c) Materials shall not be allowed in the belt conveyor entry where the material may contribute to a frictional heating hazard.\n\n(d) Splicing of any approved conveyor belt must maintain flame-resistant properties of the belt.\n\n[73 FR 80616, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":2}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4608577","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}