{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"4608553","name":"Black King I  North Portal","status":"Abandoned and Sealed","status_date":"2014-12-22","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Boone","nearest_town":"Sylvester","operator_id":"P11051","operator_name":"Elk Run Coal Company Inc","controller_id":"0127321","controller_name":"Alpha Metallurgical Resources Inc","district":"C04","office":"Madison WV Field Office","employees":0,"latitude":37.96,"longitude":-81.571111},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":8775},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4608553","name":"Black King I  North Portal"},"operator":{"type":"operator","id":"P11051","name":"Elk Run Coal Company Inc"},"controller":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"mine","id":"4608553","name":"Black King I  North Portal"},"validFrom":"1974-01-01","validTo":"2011-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608553|C02508|1974-01-01|2011-05-31"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P11051","name":"Elk Run Coal Company Inc"},"object":{"type":"mine","id":"4608553","name":"Black King I  North Portal"},"validFrom":"1996-02-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608553|P11051|1996-02-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"P11051","name":"Elk Run Coal Company Inc"},"validFrom":"1996-02-01","validTo":"2011-05-31","current":false,"derived":true,"evidenceMineId":"4608553","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608553|P11051|1996-02-01|C02508|1974-01-01|58997"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"4608553","name":"Black King I  North Portal"},"validFrom":"2011-06-01","validTo":"2016-07-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608553|0041211|2011-06-01|2016-07-25"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P11051","name":"Elk Run Coal Company Inc"},"validFrom":"2011-06-01","validTo":"2016-07-25","current":false,"derived":true,"evidenceMineId":"4608553","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608553|P11051|1996-02-01|0041211|2011-06-01|2119"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"mine","id":"4608553","name":"Black King I  North Portal"},"validFrom":"2016-07-26","validTo":"2018-11-08","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608553|0127923|2016-07-26|2018-11-08"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"operator","id":"P11051","name":"Elk Run Coal Company Inc"},"validFrom":"2016-07-26","validTo":"2018-11-08","current":false,"derived":true,"evidenceMineId":"4608553","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608553|P11051|1996-02-01|0127923|2016-07-26|25229"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"mine","id":"4608553","name":"Black King I  North Portal"},"validFrom":"2018-11-09","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608553|0127321|2018-11-09|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"operator","id":"P11051","name":"Elk Run Coal Company Inc"},"validFrom":"2018-11-09","validTo":null,"current":true,"derived":true,"evidenceMineId":"4608553","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608553|P11051|1996-02-01|0127321|2018-11-09|24864"}}],"coverage":{"historyRecords":4,"edgeCount":9,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":122,"firstDate":"2000-02-28","lastDate":"2014-09-10","metrics":{"daysLost":2989,"injuries":93,"fatalities":0,"recentRows":0,"restrictedDays":38,"contractorRecords":12},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"261988","DOCUMENT_NO":"220151100007","ACCIDENT_DT":"09/10/2014","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee has been diagnosed with Occupational Pneumoconiosis. Employee retired July 1, 2010. The safety department was notified of his diagnosis on April 15, 2015.","sourceDate":"2014-09-10"},{"SOURCE_ROW_NUMBER":"72487","DOCUMENT_NO":"220142260042","ACCIDENT_DT":"08/05/2014","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While loading cable in the feeder outside, another worker flipped a loop of cable and hit the Employee in the mouth / teeth. (3 chipped teeth)","sourceDate":"2014-08-05"},{"SOURCE_ROW_NUMBER":"167259","DOCUMENT_NO":"220142180036","ACCIDENT_DT":"07/10/2014","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee has been diagnosed with Occupational Pneumoconiosis.","sourceDate":"2014-07-10"},{"SOURCE_ROW_NUMBER":"175866","DOCUMENT_NO":"220141070012","ACCIDENT_DT":"04/16/2014","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"As Employee was cutting belt the knife slipped and cut his leg.  Employee was treated at MedExpress in Beckley where he received five (5) sutures.","sourceDate":"2014-04-16"},{"SOURCE_ROW_NUMBER":"270453","DOCUMENT_NO":"220140990019","ACCIDENT_DT":"04/03/2014","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Greaser, Grease man, Oiler, Lube man, Dragline oiler","NO_INJURIES":"1","DAYS_LOST":"64","NARRATIVE":"Employee bent over to pick up can of gear oil and felt a sharp pain in his lower back. Employee was treated at a Chiropractor in Charleston.","sourceDate":"2014-04-03"},{"SOURCE_ROW_NUMBER":"270452","DOCUMENT_NO":"220133530026","ACCIDENT_DT":"12/16/2013","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by rolling or sliding object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was taking a set of center miner drums apart in the mine yard when drums rolled over on his left foot fracturing five toes.","sourceDate":"2013-12-16"},{"SOURCE_ROW_NUMBER":"81195","DOCUMENT_NO":"220131300028","ACCIDENT_DT":"05/09/2013","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"69","NARRATIVE":"Employee was Resetting feeder, while tramming the feeder toward himself, the offside cats slipped off a ledge that was in the in the bottom Approx. 6\" high, causing the feeder to drop suddenly. Employee's leg, from the knee down in up right position was under the tram controls, this compressed his leg causing a fracture to his left Ankle.","sourceDate":"2013-05-09"},{"SOURCE_ROW_NUMBER":"29555","DOCUMENT_NO":"220131610023","ACCIDENT_DT":"01/03/2013","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Safety representative","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee exercised his rights as part 90 miner due to occupational pneumoconiosis.","sourceDate":"2013-01-03"},{"SOURCE_ROW_NUMBER":"154311","DOCUMENT_NO":"220131750073","ACCIDENT_DT":"06/13/2012","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee excercised his rights as part 90 miner due to occupational pneumoconiosis.","sourceDate":"2012-06-13"},{"SOURCE_ROW_NUMBER":"115427","DOCUMENT_NO":"220120620004","ACCIDENT_DT":"02/25/2012","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE was bolting from the operator side in #5 face one the section. Seam height is 50\" so he was bending the 48\" bolt enough to install. Bent one bolt and was straightening it back after placing in the hole with his left hand. He bumped the drill rotation with his right hand and the bolt whipped around, striking his left wrist. Received a fracture and was placed on light duty.","sourceDate":"2012-02-25"},{"SOURCE_ROW_NUMBER":"68204","DOCUMENT_NO":"220112350026","ACCIDENT_DT":"08/15/2011","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was unloading timbers from a flat car when he felt pain in his lower back.","sourceDate":"2011-08-15"},{"SOURCE_ROW_NUMBER":"167258","DOCUMENT_NO":"220111430063","ACCIDENT_DT":"05/19/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Greaser, Grease man, Oiler, Lube man, Dragline oiler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"During a power move, Employee was cutting nylon hangers from highline. Using his left hand he cut hanger while his right hand was supporting the cable. The knife cut his right forearm. He drove to Raleigh General and received four stitches. He returned to work on his next shift.","sourceDate":"2011-05-19"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2014-12-22","lastDate":"2014-12-22","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":1623,"firstDate":"2000-01-27","lastDate":"2014-09-16","metrics":{"ss":588,"delinquent":1593,"recentRows":0,"paidPenalty":1596040.2,"proposedPenalty":2174009,"currentAssessment":1596040.2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1881249","VIOLATION_NO":"9006767","ISSUE_DT":"09/16/2014","CFR_STANDARD_CD":"75.1714-4(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"499.00","CURRENT_ASSESSMENT_AMT":"499.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-09-16"},{"SOURCE_ROW_NUMBER":"1881248","VIOLATION_NO":"9006766","ISSUE_DT":"09/16/2014","CFR_STANDARD_CD":"75.1714-4(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"499.00","CURRENT_ASSESSMENT_AMT":"499.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-09-16"},{"SOURCE_ROW_NUMBER":"1881247","VIOLATION_NO":"9006765","ISSUE_DT":"08/20/2014","CFR_STANDARD_CD":"75.360(g)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"10705.00","CURRENT_ASSESSMENT_AMT":"5353.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-08-20"},{"SOURCE_ROW_NUMBER":"1881246","VIOLATION_NO":"9006764","ISSUE_DT":"08/20/2014","CFR_STANDARD_CD":"75.1501(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"52500.00","CURRENT_ASSESSMENT_AMT":"26250.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-08-20"},{"SOURCE_ROW_NUMBER":"1881245","VIOLATION_NO":"9006763","ISSUE_DT":"08/20/2014","CFR_STANDARD_CD":"75.1506(c)(2)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"52500.00","CURRENT_ASSESSMENT_AMT":"26250.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-08-20"},{"SOURCE_ROW_NUMBER":"1850943","VIOLATION_NO":"9006755","ISSUE_DT":"06/13/2014","CFR_STANDARD_CD":"75.1714-4(f)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"460.00","CURRENT_ASSESSMENT_AMT":"460.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-06-13"},{"SOURCE_ROW_NUMBER":"1850942","VIOLATION_NO":"9006754","ISSUE_DT":"06/13/2014","CFR_STANDARD_CD":"75.1714-4(f)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"460.00","CURRENT_ASSESSMENT_AMT":"460.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-06-13"},{"SOURCE_ROW_NUMBER":"1850941","VIOLATION_NO":"9006753","ISSUE_DT":"05/15/2014","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2106.00","CURRENT_ASSESSMENT_AMT":"2106.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-05-15"},{"SOURCE_ROW_NUMBER":"1850940","VIOLATION_NO":"9006752","ISSUE_DT":"05/15/2014","CFR_STANDARD_CD":"75.604(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2106.00","CURRENT_ASSESSMENT_AMT":"2106.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-05-15"},{"SOURCE_ROW_NUMBER":"1850939","VIOLATION_NO":"9006751","ISSUE_DT":"05/15/2014","CFR_STANDARD_CD":"75.1107","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1657.00","CURRENT_ASSESSMENT_AMT":"1657.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-05-15"},{"SOURCE_ROW_NUMBER":"1850938","VIOLATION_NO":"9006750","ISSUE_DT":"05/14/2014","CFR_STANDARD_CD":"75.604(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2106.00","CURRENT_ASSESSMENT_AMT":"2106.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-05-14"},{"SOURCE_ROW_NUMBER":"1850937","VIOLATION_NO":"9006749","ISSUE_DT":"05/14/2014","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"425.00","CURRENT_ASSESSMENT_AMT":"425.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-05-14"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":459,"firstDate":"2003-02-26","lastDate":"2016-05-31","metrics":{"appeals":0,"decisions":459,"recentRows":0,"decisionPenalty":1232254.2,"originalPenalty":1814960},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"392012","VIOLATION_NO":"9006765","DOCKET_NO":"WEVA 2015-0349","DECISION_DT":"05/31/2016","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"10705.00","DECISION_PENALTY_AMT":"5353.00","JUDGE_FIRST_NAME":"Jerold","JUDGE_LAST_NAME":"Feldman","sourceDate":"2016-05-31"},{"SOURCE_ROW_NUMBER":"152524","VIOLATION_NO":"9006763","DOCKET_NO":"WEVA 2015-0570","DECISION_DT":"05/12/2016","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"52500.00","DECISION_PENALTY_AMT":"26250.00","JUDGE_FIRST_NAME":"Jerold","JUDGE_LAST_NAME":"Feldman","sourceDate":"2016-05-12"},{"SOURCE_ROW_NUMBER":"151792","VIOLATION_NO":"9006764","DOCKET_NO":"WEVA 2015-0570","DECISION_DT":"05/12/2016","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"52500.00","DECISION_PENALTY_AMT":"26250.00","JUDGE_FIRST_NAME":"Jerold","JUDGE_LAST_NAME":"Feldman","sourceDate":"2016-05-12"},{"SOURCE_ROW_NUMBER":"386812","VIOLATION_NO":"9006734","DOCKET_NO":"WEVA 2014-1106","DECISION_DT":"05/06/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1657.00","DECISION_PENALTY_AMT":"700.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2015-05-06"},{"SOURCE_ROW_NUMBER":"386087","VIOLATION_NO":"9006739","DOCKET_NO":"WEVA 2014-1106","DECISION_DT":"05/06/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"11306.00","DECISION_PENALTY_AMT":"5000.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2015-05-06"},{"SOURCE_ROW_NUMBER":"144571","VIOLATION_NO":"9006743","DOCKET_NO":"WEVA 2014-1106","DECISION_DT":"05/06/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"946.00","DECISION_PENALTY_AMT":"946.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2015-05-06"},{"SOURCE_ROW_NUMBER":"144570","VIOLATION_NO":"9006735","DOCKET_NO":"WEVA 2014-1106","DECISION_DT":"05/06/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1657.00","DECISION_PENALTY_AMT":"700.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2015-05-06"},{"SOURCE_ROW_NUMBER":"144540","VIOLATION_NO":"9006736","DOCKET_NO":"WEVA 2014-1106","DECISION_DT":"05/06/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"8209.00","DECISION_PENALTY_AMT":"6000.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2015-05-06"},{"SOURCE_ROW_NUMBER":"144373","VIOLATION_NO":"9006740","DOCKET_NO":"WEVA 2014-1106","DECISION_DT":"05/06/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"18271.00","DECISION_PENALTY_AMT":"9000.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2015-05-06"},{"SOURCE_ROW_NUMBER":"144372","VIOLATION_NO":"9006737","DOCKET_NO":"WEVA 2014-1106","DECISION_DT":"05/06/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"8209.00","DECISION_PENALTY_AMT":"6000.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2015-05-06"},{"SOURCE_ROW_NUMBER":"384492","VIOLATION_NO":"9005655","DOCKET_NO":"WEVA 2014-0846","DECISION_DT":"04/10/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"745.00","DECISION_PENALTY_AMT":"745.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2015-04-10"},{"SOURCE_ROW_NUMBER":"383833","VIOLATION_NO":"9005670","DOCKET_NO":"WEVA 2014-0846","DECISION_DT":"04/10/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4689.00","DECISION_PENALTY_AMT":"3789.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2015-04-10"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":2804,"firstDate":"2000-01-10","lastDate":"2015-06-18","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":390,"validSamples":2414,"maxConcentration":32.183,"concentrationTotal":1606.196},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"464489","CASS_NUM":"51236120","SMP_TAKEN_DT":"6/18/2015","CONC":".135","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"PREDATED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-06-18"},{"SOURCE_ROW_NUMBER":"1456626","CASS_NUM":"51280137","SMP_TAKEN_DT":"6/25/2014","CONC":".153","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-06-25"},{"SOURCE_ROW_NUMBER":"1418388","CASS_NUM":"51280073","SMP_TAKEN_DT":"6/25/2014","CONC":"1.073","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-06-25"},{"SOURCE_ROW_NUMBER":"1213435","CASS_NUM":"51280142","SMP_TAKEN_DT":"6/25/2014","CONC":".181","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-06-25"},{"SOURCE_ROW_NUMBER":"669827","CASS_NUM":"51280155","SMP_TAKEN_DT":"6/25/2014","CONC":"1.769","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-06-25"},{"SOURCE_ROW_NUMBER":"1361227","CASS_NUM":"51280147","SMP_TAKEN_DT":"6/24/2014","CONC":".852","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-06-24"},{"SOURCE_ROW_NUMBER":"1285146","CASS_NUM":"51279994","SMP_TAKEN_DT":"6/24/2014","CONC":".553","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-06-24"},{"SOURCE_ROW_NUMBER":"323141","CASS_NUM":"51280129","SMP_TAKEN_DT":"6/24/2014","CONC":".189","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-06-24"},{"SOURCE_ROW_NUMBER":"274659","CASS_NUM":"51280140","SMP_TAKEN_DT":"6/24/2014","CONC":"2.342","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-06-24"},{"SOURCE_ROW_NUMBER":"1110939","CASS_NUM":"51280050","SMP_TAKEN_DT":"6/23/2014","CONC":".527","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-06-23"},{"SOURCE_ROW_NUMBER":"761525","CASS_NUM":"51280135","SMP_TAKEN_DT":"6/23/2014","CONC":".122","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-06-23"},{"SOURCE_ROW_NUMBER":"596681","CASS_NUM":"51280037","SMP_TAKEN_DT":"6/23/2014","CONC":"1.348","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-06-23"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":68,"firstDate":"2001-10-03","lastDate":"2014-12-05","metrics":{"linkedIssuances":68},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":460,"firstDate":"2003-04-10","lastDate":"2014-08-20","metrics":{"decisions":460,"ssChanged":195,"recentRows":0,"decisionPenalty":1206598.7,"proposedPenalty":1779215},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"372376","CITATION_NO":"9006764","CITATION_ISSUE_DT":"08/20/2014","DOCKET_NO":"WEVA 2015-0570","DECISION_DT":"05/12/2016","CFR_STANDARD_CODE":"75.1501(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"52500.00","DECISION_PENALTY_AMT":"26250.00","sourceDate":"2014-08-20"},{"SOURCE_ROW_NUMBER":"320228","CITATION_NO":"9006763","CITATION_ISSUE_DT":"08/20/2014","DOCKET_NO":"WEVA 2015-0570","DECISION_DT":"05/12/2016","CFR_STANDARD_CODE":"75.1506(c)(2)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"52500.00","DECISION_PENALTY_AMT":"26250.00","sourceDate":"2014-08-20"},{"SOURCE_ROW_NUMBER":"315648","CITATION_NO":"9006765","CITATION_ISSUE_DT":"08/20/2014","DOCKET_NO":"WEVA 2015-0349","DECISION_DT":"05/31/2016","CFR_STANDARD_CODE":"75.360(g)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"10705.00","DECISION_PENALTY_AMT":"5353.00","sourceDate":"2014-08-20"},{"SOURCE_ROW_NUMBER":"263813","CITATION_NO":"9006743","CITATION_ISSUE_DT":"04/29/2014","DOCKET_NO":"WEVA 2014-1106","DECISION_DT":"05/06/2015","CFR_STANDARD_CODE":"75.1722(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"946.00","DECISION_PENALTY_AMT":"946.00","sourceDate":"2014-04-29"},{"SOURCE_ROW_NUMBER":"434191","CITATION_NO":"9006739","CITATION_ISSUE_DT":"04/28/2014","DOCKET_NO":"WEVA 2014-1106","DECISION_DT":"05/06/2015","CFR_STANDARD_CODE":"75.1731(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"11306.00","DECISION_PENALTY_AMT":"5000.00","sourceDate":"2014-04-28"},{"SOURCE_ROW_NUMBER":"377634","CITATION_NO":"9006740","CITATION_ISSUE_DT":"04/28/2014","DOCKET_NO":"WEVA 2014-1106","DECISION_DT":"05/06/2015","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"18271.00","DECISION_PENALTY_AMT":"9000.00","sourceDate":"2014-04-28"},{"SOURCE_ROW_NUMBER":"376939","CITATION_NO":"9006734","CITATION_ISSUE_DT":"04/28/2014","DOCKET_NO":"WEVA 2014-1106","DECISION_DT":"05/06/2015","CFR_STANDARD_CODE":"75.1103-4(a)(1)(iv)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1657.00","DECISION_PENALTY_AMT":"700.00","sourceDate":"2014-04-28"},{"SOURCE_ROW_NUMBER":"375893","CITATION_NO":"9006737","CITATION_ISSUE_DT":"04/28/2014","DOCKET_NO":"WEVA 2014-1106","DECISION_DT":"05/06/2015","CFR_STANDARD_CODE":"75.1505(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"8209.00","DECISION_PENALTY_AMT":"6000.00","sourceDate":"2014-04-28"},{"SOURCE_ROW_NUMBER":"262936","CITATION_NO":"9006736","CITATION_ISSUE_DT":"04/28/2014","DOCKET_NO":"WEVA 2014-1106","DECISION_DT":"05/06/2015","CFR_STANDARD_CODE":"75.1505(a)(4)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"8209.00","DECISION_PENALTY_AMT":"6000.00","sourceDate":"2014-04-28"},{"SOURCE_ROW_NUMBER":"206051","CITATION_NO":"9006735","CITATION_ISSUE_DT":"04/28/2014","DOCKET_NO":"WEVA 2014-1106","DECISION_DT":"05/06/2015","CFR_STANDARD_CODE":"75.1103-4(a)(1)(iv)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1657.00","DECISION_PENALTY_AMT":"700.00","sourceDate":"2014-04-28"},{"SOURCE_ROW_NUMBER":"203014","CITATION_NO":"9005672","CITATION_ISSUE_DT":"03/12/2014","DOCKET_NO":"WEVA 2014-0999","DECISION_DT":"03/13/2015","CFR_STANDARD_CODE":"75.1403","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"499.00","DECISION_PENALTY_AMT":"400.00","sourceDate":"2014-03-12"},{"SOURCE_ROW_NUMBER":"151771","CITATION_NO":"9005670","CITATION_ISSUE_DT":"03/10/2014","DOCKET_NO":"WEVA 2014-0846","DECISION_DT":"04/10/2015","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"4689.00","DECISION_PENALTY_AMT":"3789.00","sourceDate":"2014-03-10"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":849,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":6,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":174,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":6,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":4,"firstDate":"1996-02-01","lastDate":"1996-02-01","metrics":{"recentRows":0,"currentOperatorTenures":4,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":178,"firstDate":"2000-01-24","lastDate":"2015-04-09","metrics":{"inspectors":356,"recentRows":0,"onSiteHours":8844.25,"inspectionHours":15529.75,"inspectionSamples":1037},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"604849","EVENT_NO":"6302146","INSPECTION_BEGIN_DT":"04/09/2015","INSPECTION_END_DT":"04/09/2015","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":".75","sourceDate":"2015-04-09"},{"SOURCE_ROW_NUMBER":"1058696","EVENT_NO":"6308672","INSPECTION_BEGIN_DT":"03/30/2015","INSPECTION_END_DT":"03/30/2015","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.25","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2015-03-30"},{"SOURCE_ROW_NUMBER":"207712","EVENT_NO":"6308659","INSPECTION_BEGIN_DT":"10/03/2014","INSPECTION_END_DT":"12/10/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"28","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2014-10-03"},{"SOURCE_ROW_NUMBER":"230948","EVENT_NO":"6308753","INSPECTION_BEGIN_DT":"07/01/2014","INSPECTION_END_DT":"09/19/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"65","SUM_TOTAL_ON_SITE_HOURS":"38.5","sourceDate":"2014-07-01"},{"SOURCE_ROW_NUMBER":"414495","EVENT_NO":"6300500","INSPECTION_BEGIN_DT":"04/01/2014","INSPECTION_END_DT":"06/25/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"262","SUM_TOTAL_ON_SITE_HOURS":"175.75","sourceDate":"2014-04-01"},{"SOURCE_ROW_NUMBER":"1019053","EVENT_NO":"6298290","INSPECTION_BEGIN_DT":"01/08/2014","INSPECTION_END_DT":"03/31/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"291.5","SUM_TOTAL_ON_SITE_HOURS":"190.25","sourceDate":"2014-01-08"},{"SOURCE_ROW_NUMBER":"260877","EVENT_NO":"6298284","INSPECTION_BEGIN_DT":"10/22/2013","INSPECTION_END_DT":"12/31/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"133.75","SUM_TOTAL_ON_SITE_HOURS":"83","sourceDate":"2013-10-22"},{"SOURCE_ROW_NUMBER":"749345","EVENT_NO":"6298283","INSPECTION_BEGIN_DT":"10/02/2013","INSPECTION_END_DT":"10/17/2013","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"87","SUM_TOTAL_ON_SITE_HOURS":"54.5","sourceDate":"2013-10-02"},{"SOURCE_ROW_NUMBER":"398100","EVENT_NO":"6300107","INSPECTION_BEGIN_DT":"07/08/2013","INSPECTION_END_DT":"09/30/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"414.75","SUM_TOTAL_ON_SITE_HOURS":"263.75","sourceDate":"2013-07-08"},{"SOURCE_ROW_NUMBER":"300201","EVENT_NO":"6297209","INSPECTION_BEGIN_DT":"04/22/2013","INSPECTION_END_DT":"04/25/2013","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.75","SUM_TOTAL_ON_SITE_HOURS":"2.25","sourceDate":"2013-04-22"},{"SOURCE_ROW_NUMBER":"493603","EVENT_NO":"6300104","INSPECTION_BEGIN_DT":"04/01/2013","INSPECTION_END_DT":"06/27/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"385.25","SUM_TOTAL_ON_SITE_HOURS":"229.75","sourceDate":"2013-04-01"},{"SOURCE_ROW_NUMBER":"236169","EVENT_NO":"6298269","INSPECTION_BEGIN_DT":"01/02/2013","INSPECTION_END_DT":"03/27/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"327","SUM_TOTAL_ON_SITE_HOURS":"217","sourceDate":"2013-01-02"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":24,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002-Q4":{"hours":53224,"employees":97,"production":156702},"2002-Q3":{"hours":57615,"employees":98,"production":172385},"2002-Q2":{"hours":61854,"employees":97,"production":146972},"2002-Q1":{"hours":52865,"employees":87,"production":126749},"2001-Q4":{"hours":48564,"employees":87,"production":127420},"2001-Q3":{"hours":47726,"employees":85,"production":151733},"2001-Q2":{"hours":43936,"employees":71,"production":159066},"2001-Q1":{"hours":41009,"employees":68,"production":206415},"2000-Q4":{"hours":37762,"employees":65,"production":203296},"2000-Q3":{"hours":41115,"employees":64,"production":210688},"2000-Q2":{"hours":39031,"employees":63,"production":216678},"2000-Q1":{"hours":41767,"employees":65,"production":235890}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":33,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2005":{"hours":117101,"employees":45,"production":319251},"2006":{"hours":83883,"employees":33,"production":205252},"2007":{"hours":92008,"employees":36,"production":163869},"2008":{"hours":91576,"employees":38,"production":184680},"2009":{"hours":106143,"employees":45,"production":180240},"2010":{"hours":107698,"employees":45,"production":159778},"2011":{"hours":108140,"employees":48,"production":166011},"2012":{"hours":129783,"employees":53,"production":215789},"2013":{"hours":124108,"employees":49,"production":174470},"2014":{"hours":72454,"employees":35,"production":88356}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":89,"firstDate":"2000-03-15","lastDate":"2013-08-22","metrics":{"recentRows":0,"doseOver100":18,"actDoseTotal":7461,"pelDoseTotal":6014},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"238454","EVENT_NO":"6300107","SURVEY_DATE":"08/22/2013","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"82","PEL_DOSE_90":"64","SURVEY_TYPE":"F","sourceDate":"2013-08-22"},{"SOURCE_ROW_NUMBER":"238453","EVENT_NO":"6300107","SURVEY_DATE":"08/08/2013","OCCUPATION_CD_DESC":"MOTORMAN","MACHINE_CD":"25","MANUFACTURER_CD":"119","ACT_DOSE_85":"73","PEL_DOSE_90":"73","SURVEY_TYPE":"I","sourceDate":"2013-08-08"},{"SOURCE_ROW_NUMBER":"238452","EVENT_NO":"6300107","SURVEY_DATE":"08/08/2013","OCCUPATION_CD_DESC":"MOTORMAN","MACHINE_CD":"25","MANUFACTURER_CD":"119","ACT_DOSE_85":"82","PEL_DOSE_90":"82","SURVEY_TYPE":"I","sourceDate":"2013-08-08"},{"SOURCE_ROW_NUMBER":"238451","EVENT_NO":"6300107","SURVEY_DATE":"08/08/2013","OCCUPATION_CD_DESC":"DISPATCHER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"68","PEL_DOSE_90":"68","SURVEY_TYPE":"I","sourceDate":"2013-08-08"},{"SOURCE_ROW_NUMBER":"238450","EVENT_NO":"6300107","SURVEY_DATE":"08/08/2013","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"70","PEL_DOSE_90":"69","SURVEY_TYPE":"I","sourceDate":"2013-08-08"},{"SOURCE_ROW_NUMBER":"238449","EVENT_NO":"6300107","SURVEY_DATE":"08/08/2013","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","MANUFACTURER_CD":"038","ACT_DOSE_85":"74","PEL_DOSE_90":"73","SURVEY_TYPE":"I","sourceDate":"2013-08-08"},{"SOURCE_ROW_NUMBER":"238448","EVENT_NO":"6300107","SURVEY_DATE":"08/08/2013","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"78","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2013-08-08"},{"SOURCE_ROW_NUMBER":"238447","EVENT_NO":"6300107","SURVEY_DATE":"08/08/2013","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"73","PEL_DOSE_90":"52","SURVEY_TYPE":"I","sourceDate":"2013-08-08"},{"SOURCE_ROW_NUMBER":"238446","EVENT_NO":"6300107","SURVEY_DATE":"08/08/2013","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"079","ACT_DOSE_85":"97","PEL_DOSE_90":"74","SURVEY_TYPE":"I","sourceDate":"2013-08-08"},{"SOURCE_ROW_NUMBER":"238445","EVENT_NO":"6300107","SURVEY_DATE":"08/08/2013","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"079","ACT_DOSE_85":"91","PEL_DOSE_90":"63","SURVEY_TYPE":"I","sourceDate":"2013-08-08"},{"SOURCE_ROW_NUMBER":"238444","EVENT_NO":"6300107","SURVEY_DATE":"08/08/2013","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"163","PEL_DOSE_90":"145","SURVEY_TYPE":"I","sourceDate":"2013-08-08"},{"SOURCE_ROW_NUMBER":"238443","EVENT_NO":"6300107","SURVEY_DATE":"07/23/2013","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"39","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2013-07-23"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":226,"firstDate":"2000-01-06","lastDate":"2014-06-04","metrics":{"recentRows":0,"voidSamples":23,"maxQuartzPct":32.3,"validSamples":203,"quartzPctTotal":2440.2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"55661","CASSETTE_NO":"51258072","SAMPLE_DT":"06/04/2014","QUARTZ_PCT":"09.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"UNACCEPTABLE TIMEFRAME","sourceDate":"2014-06-04"},{"SOURCE_ROW_NUMBER":"4930","CASSETTE_NO":"51258058","SAMPLE_DT":"06/04/2014","QUARTZ_PCT":"09.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"UNACCEPTABLE TIMEFRAME","sourceDate":"2014-06-04"},{"SOURCE_ROW_NUMBER":"70107","CASSETTE_NO":"58155308","SAMPLE_DT":"05/21/2014","QUARTZ_PCT":"14.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-05-21"},{"SOURCE_ROW_NUMBER":"26025","CASSETTE_NO":"58155216","SAMPLE_DT":"05/21/2014","QUARTZ_PCT":"14.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-05-21"},{"SOURCE_ROW_NUMBER":"55962","CASSETTE_NO":"58155080","SAMPLE_DT":"03/25/2014","QUARTZ_PCT":"05.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-03-25"},{"SOURCE_ROW_NUMBER":"45325","CASSETTE_NO":"58124508","SAMPLE_DT":"02/12/2014","QUARTZ_PCT":"06.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-02-12"},{"SOURCE_ROW_NUMBER":"133278","CASSETTE_NO":"58124359","SAMPLE_DT":"11/06/2013","QUARTZ_PCT":"07.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-11-06"},{"SOURCE_ROW_NUMBER":"79026","CASSETTE_NO":"51225013","SAMPLE_DT":"11/05/2013","QUARTZ_PCT":"05.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-11-05"},{"SOURCE_ROW_NUMBER":"130816","CASSETTE_NO":"51207782","SAMPLE_DT":"10/31/2013","QUARTZ_PCT":"01.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-10-31"},{"SOURCE_ROW_NUMBER":"139255","CASSETTE_NO":"51224980","SAMPLE_DT":"09/23/2013","QUARTZ_PCT":"04.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-09-23"},{"SOURCE_ROW_NUMBER":"37232","CASSETTE_NO":"58011349","SAMPLE_DT":"08/05/2013","QUARTZ_PCT":"09.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-08-05"},{"SOURCE_ROW_NUMBER":"111980","CASSETTE_NO":"58011384","SAMPLE_DT":"07/23/2013","QUARTZ_PCT":"09.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-07-23"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":1660,"firstDate":"2000-01-27","lastDate":"2014-09-16","metrics":{"ss":587,"amountDue":1596040.2,"contested":315,"amountPaid":1596040.2,"recentRows":0,"section104d":53,"unterminated":14,"proposedPenalty":2174009},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2733304","VIOLATION_NO":"9006767","VIOLATION_ISSUE_DT":"09/16/2014","SIG_SUB":"N","PART_SECTION":"75.1714-4(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/16/2014","PROPOSED_PENALTY":"499","AMOUNT_DUE":"499","AMOUNT_PAID":"499","CONTESTED_IND":"N","sourceDate":"2014-09-16"},{"SOURCE_ROW_NUMBER":"2733303","VIOLATION_NO":"9006766","VIOLATION_ISSUE_DT":"09/16/2014","SIG_SUB":"N","PART_SECTION":"75.1714-4(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/16/2014","PROPOSED_PENALTY":"499","AMOUNT_DUE":"499","AMOUNT_PAID":"499","CONTESTED_IND":"N","sourceDate":"2014-09-16"},{"SOURCE_ROW_NUMBER":"2733302","VIOLATION_NO":"9006765","VIOLATION_ISSUE_DT":"08/20/2014","SIG_SUB":"N","PART_SECTION":"75.360(g)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"10","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"08/20/2014","PROPOSED_PENALTY":"10705","AMOUNT_DUE":"5353","AMOUNT_PAID":"5353","CONTESTED_IND":"N","sourceDate":"2014-08-20"},{"SOURCE_ROW_NUMBER":"2733301","VIOLATION_NO":"9006764","VIOLATION_ISSUE_DT":"08/20/2014","SIG_SUB":"Y","PART_SECTION":"75.1501(a)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"10","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"08/20/2014","PROPOSED_PENALTY":"52500","AMOUNT_DUE":"26250","AMOUNT_PAID":"26250","CONTESTED_IND":"N","sourceDate":"2014-08-20"},{"SOURCE_ROW_NUMBER":"2733300","VIOLATION_NO":"9006763","VIOLATION_ISSUE_DT":"08/20/2014","SIG_SUB":"Y","PART_SECTION":"75.1506(c)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"10","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"08/21/2014","PROPOSED_PENALTY":"52500","AMOUNT_DUE":"26250","AMOUNT_PAID":"26250","CONTESTED_IND":"N","sourceDate":"2014-08-20"},{"SOURCE_ROW_NUMBER":"2733017","VIOLATION_NO":"9006755","VIOLATION_ISSUE_DT":"06/13/2014","SIG_SUB":"N","PART_SECTION":"75.1714-4(f)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/13/2014","PROPOSED_PENALTY":"460","AMOUNT_DUE":"460","AMOUNT_PAID":"460","CONTESTED_IND":"N","sourceDate":"2014-06-13"},{"SOURCE_ROW_NUMBER":"2733016","VIOLATION_NO":"9006754","VIOLATION_ISSUE_DT":"06/13/2014","SIG_SUB":"N","PART_SECTION":"75.1714-4(f)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/13/2014","PROPOSED_PENALTY":"460","AMOUNT_DUE":"460","AMOUNT_PAID":"460","CONTESTED_IND":"N","sourceDate":"2014-06-13"},{"SOURCE_ROW_NUMBER":"2733015","VIOLATION_NO":"9006753","VIOLATION_ISSUE_DT":"05/15/2014","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/21/2014","PROPOSED_PENALTY":"2106","AMOUNT_DUE":"2106","AMOUNT_PAID":"2106","CONTESTED_IND":"N","sourceDate":"2014-05-15"},{"SOURCE_ROW_NUMBER":"2733014","VIOLATION_NO":"9006752","VIOLATION_ISSUE_DT":"05/15/2014","SIG_SUB":"Y","PART_SECTION":"75.604(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/15/2014","PROPOSED_PENALTY":"2106","AMOUNT_DUE":"2106","AMOUNT_PAID":"2106","CONTESTED_IND":"N","sourceDate":"2014-05-15"},{"SOURCE_ROW_NUMBER":"2733013","VIOLATION_NO":"9006751","VIOLATION_ISSUE_DT":"05/15/2014","SIG_SUB":"N","PART_SECTION":"75.1107","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"13","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/21/2014","PROPOSED_PENALTY":"1657","AMOUNT_DUE":"1657","AMOUNT_PAID":"1657","CONTESTED_IND":"N","sourceDate":"2014-05-15"},{"SOURCE_ROW_NUMBER":"2733012","VIOLATION_NO":"9006750","VIOLATION_ISSUE_DT":"05/14/2014","SIG_SUB":"Y","PART_SECTION":"75.604(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/14/2014","PROPOSED_PENALTY":"2106","AMOUNT_DUE":"2106","AMOUNT_PAID":"2106","CONTESTED_IND":"N","sourceDate":"2014-05-14"},{"SOURCE_ROW_NUMBER":"2733011","VIOLATION_NO":"9006749","VIOLATION_ISSUE_DT":"05/14/2014","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/15/2014","PROPOSED_PENALTY":"425","AMOUNT_DUE":"425","AMOUNT_PAID":"425","CONTESTED_IND":"N","sourceDate":"2014-05-14"}]}],"safety":{"href":"/api/v1/mines/4608553/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4608553/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1714-4","heading":"Additional self-contained self-rescuers (SCSRs).","id":"75.1714-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Additional SCSRs in work places. In addition to the requirements in §§ 75.1714, 75.1714-1, 75.1714-2, and 75.1714-3 of this part, the mine operator shall provide the following:\n\n(1) At least one additional SCSR, which provides protection for a period of one hour or longer, for each person at a fixed underground work location.\n\n(2) Additional SCSRs along the normal travel routes for pumpers, examiners, and other persons who do not have a fixed work location to be stored at a distance an average miner could walk in 30 minutes. The SCSR storage locations shall be determined by using one of the methods found under paragraph (c)(2) of this section.\n\n(b) Additional SCSRs on mantrips. If a mantrip or mobile equipment is used to enter or exit the mine, at least one additional SCSR, which provides protection for a period of one hour or longer, shall be available for each person who uses such transportation from portal to portal.\n\n(c) Additional SCSRs in escapeways. When each person underground cannot safely evacuate the mine within 30 minutes, the mine operator shall provide additional SCSRs stored in each required escapeway.\n\n(1) Each storage location shall contain at least one SCSR, which provides protection for a period of one hour or longer, for every person who will be inby that location.\n\n(2) Storage locations shall be spaced along each escapeway at 30-minute travel distances no greater than the distances determined by—\n\n(i) Calculating the distance an average miner walks in 30 minutes by using the time necessary for each miner in a sample of typical miners to walk a typical length of each escapeway; or\n\n(ii) Using the SCSR storage location spacing specified in the following table, except for escapeways with grades over 5 percent.\n\nAverage entry height Maximum distancebetween SCSR storage locations (in ft.) <40 in. (Crawl) 2,200 >40-<50 in. (Duck Walk) 3,300 >50-<65 in. (Walk Head Bent) 4,400 >65 in. (Walk Erect) 5,700\n\n(d) Additional SCSRs in hardened rooms. As an alternative to providing SCSR storage locations in each escapeway, the mine operator may store SCSRs in a hardened room located between adjacent escapeways.\n\n(1) The hardened room shall be designed and constructed to the same explosion force criteria as seals.\n\n(2) The hardened room shall include a means to provide independent, positive pressure ventilation from the surface during an emergency.\n\n(3) The District Manager shall approve the design and construction of hardened rooms in the ventilation plan.\n\n(4) These SCSR storage locations shall be spaced in accordance with paragraph (c) of this section.\n\n(e) Storage location accessibility. All SCSRs required under this section shall be stored according to the manufacturers' instructions, in conspicuous locations readily accessible by each person in the mine.\n\n(f) Storage location signs. A sign made of reflective material with the words “SCSRs” or “SELF-RESCUERS” shall be conspicuously posted at each storage location. Direction signs made of a reflective material shall be posted leading to each storage location.\n\n[71 FR 71454, Dec. 8, 2006]","occurrenceCount":4},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.360","heading":"Preshift examination at fixed intervals.","id":"75.360","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.360","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) Except as provided in paragraph (a)(2) of this section, a certified person designated by the operator must make a preshift examination within 3 hours preceding the beginning of any 8-hour interval during which any person is scheduled to work or travel underground. No person other than certified examiners may enter or remain in any underground area unless a preshift examination has been completed for the established 8-hour interval. The operator must establish 8-hour intervals of time subject to the required preshift examinations.\n\n(2) Preshift examinations of areas where pumpers are scheduled to work or travel shall not be required prior to the pumper entering the areas if the pumper is a certified person and the pumper conducts an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, tests for methane and oxygen deficiency, and determines if the air is moving in its proper direction in the area where the pumper works or travels. The examination of the area must be completed before the pumper performs any other work. A record of all hazardous conditions and violations of the mandatory health or safety standards found by the pumper shall be made and retained in accordance with § 75.363 of this part.\n\n(b) The person conducting the preshift examination shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction at the following locations:\n\n(1) Roadways, travelways and track haulageways where persons are scheduled, prior to the beginning of the preshift examination, to work or travel during the oncoming shift.\n\n(2) Belt conveyors that will be used to transport persons during the oncoming shift and the entries in which these belt conveyors are located.\n\n(3) Working sections and areas where mechanized mining equipment is being installed or removed, if anyone is scheduled to work on the section or in the area during the oncoming shift. The scope of the examination shall include the working places, approaches to worked-out areas and ventilation controls on these sections and in these areas, and the examination shall include tests of the roof, face and rib conditions on these sections and in these areas.\n\n(4) Approaches to worked-out areas along intake air courses and at the entries used to carry air into worked-out areas if the intake air passing the approaches is used to ventilate working sections where anyone is scheduled to work during the oncoming shift. The examination of the approaches to the worked-out areas shall be made in the intake air course immediately inby and outby each entry used to carry air into the worked-out area. An examination of the entries used to carry air into the worked-out areas shall be conducted at a point immediately inby the intersection of each entry with the intake air course.\n\n(5) Seals along intake air courses where intake air passes by a seal to ventilate working sections where anyone is scheduled to work during the oncoming shift.\n\n(6)(i) Entries and rooms developed after November 15, 1992, and developed more than 2 crosscuts off an intake air course without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift; and,\n\n(ii) Entries and rooms developed after November 15, 1992, and driven more than 20 feet off an intake air course without a crosscut and without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift.\n\n(7) Areas where trolley wires or trolley feeder wires are to be or will remain energized during the oncoming shift.\n\n(8) High spots along intake air courses where methane is likely to accumulate, if equipment will be operated in the area during the shift.\n\n(9) Underground electrical installations referred to in § 75.340(a), except those pumps listed in § 75.340 (b)(2) through (b)(6), and areas where compressors subject to § 75.344 are installed if the electrical installation or compressor is or will be energized during the shift.\n\n(10) Other areas where work or travel during the oncoming shift is scheduled prior to the beginning of the preshift examination.\n\n(11) Preshift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) The person conducting the preshift examination shall determine the volume of air entering each of the following areas if anyone is scheduled to work in the areas during the oncoming shift:\n\n(1) In the last open crosscut of each set of entries or rooms on each working section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) On each longwall or shortwall in the intake entry or entries at the intake end of the longwall or shortwall face immediately outby the face and the velocity of air at each end of the face at the locations specified in the approved ventilation plan.\n\n(3) At the intake end of any pillar line—\n\n(i) If a single split of air is used, in the intake entry furthest from the return air course, immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) If a split system is used, in the intake entries of each split immediately inby the split point.\n\n(d) The person conducting the preshift examination shall check the refuge alternative for damage, the integrity of the tamper-evident seal and the mechanisms required to deploy the refuge alternative, and the ready availability of compressed oxygen and air.\n\n(e) The district manager may require the operator to examine other areas of the mine or examine for other hazards and violations of other mandatory health or safety standards found during the preshift examination.\n\n(f) Certification. At each working place examined, the person doing the preshift examination shall certify by initials, date, and the time, that the examination was made. In areas required to be examined outby a working section, the certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(g) Recordkeeping. A record of the results of each preshift examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards and their locations found by the examiner during each examination, and of the results and locations of air and methane measurements, shall be made on the surface before any persons, other than certified persons conducting examinations required by this subpart, enter any underground area of the mine. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the certified person who made the examination or by a person designated by the operator. If the record is made by someone other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. A record shall also be made by a certified person of the action taken to correct hazardous conditions and violations of mandatory health or safety standards found during the preshift examination. All preshift and corrective action records shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(h) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 62 FR 35085, June 30, 1997; 64 FR 45170, Aug. 19, 1999; 73 FR 80697, Dec. 31, 2008; 77 FR 20714, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","heading":"Emergency evacuations.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-P/section-75.1501","part":"75","subchapter":"O","subpart":"P","id":"75.1501","citation":"30 CFR 75.1501","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1506","heading":"Refuge alternatives.","id":"75.1506","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-P/section-75.1506","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"P","subpartHeading":"Subpart P—Mine Emergencies","text":"(a) Each operator shall provide refuge alternatives and components as follows:\n\n(1) Prefabricated self-contained units, including the structural, breathable air, air monitoring, and harmful gas removal components of the unit, shall be approved under 30 CFR part 7; and\n\n(2) The structural components of units consisting of 15 psi stoppings constructed prior to an event shall be approved by the District Manager, and the breathable air, air monitoring, and harmful gas removal components of these units shall be approved under 30 CFR part 7.\n\n(3) Prefabricated refuge alternative structures that states have approved and those that MSHA has accepted in approved Emergency Response Plans (ERPs) that are in service prior to March 2, 2009 are permitted until December 31, 2018, or until replaced, whichever comes first. Breathable air, air-monitoring, and harmful gas removal components of either a prefabricated self-contained unit or a unit consisting of 15 psi stoppings constructed prior to an event in a secure space and an isolated atmosphere that states have approved and those that MSHA has accepted in approved ERPs that are in use prior to March 2, 2009 are permitted until December 31, 2013, or until replaced, whichever comes first. Refuge alternatives consisting of materials pre-positioned for miners to deploy in a secure space with an isolated atmosphere that MSHA has accepted in approved ERPs that are in use prior to March 2, 2009 are permitted until December 31, 2010, or until replaced, whichever comes first.\n\n(b) Except as permitted under paragraph (a)(3) of this section, each operator shall provide refuge alternatives with sufficient capacity to accommodate all persons working underground.\n\n(1) Refuge alternatives shall provide at least 15 square feet of floor space per person and 30 to 60 cubic feet of volume per person according to the following chart. The airlock can be included in the space and volume if waste is disposed outside the refuge alternative.\n\nMining height (inches) Unrestricted volume(cubic feet) per person* 36 or less 30 >36-≤42 37.5 >42-≤48 45 >48-≤54 52.5 >54 60 * Includes an adjustment of 12 inches for clearances.\n\n(2) Refuge alternatives for working sections shall accommodate the maximum number of persons that can be expected on or near the section at any time.\n\n(3) Each refuge alternative for outby areas shall accommodate persons reasonably expected to use it.\n\n(c) Refuge alternatives shall be provided at the following locations:\n\n(1) Within 1,000 feet from the nearest working face and from locations where mechanized mining equipment is being installed or removed except that for underground anthracite coal mines that have no electrical face equipment, refuge alternatives shall be provided if the nearest working face is greater than 2,000 feet from the surface.\n\n(2) Spaced within one-hour travel distances in outby areas where persons work such that persons in outby areas are never more than a 30-minute travel distance from a refuge alternative or safe exit. However, the operator may request and the District Manager may approve a different location in the ERP. The operator's request shall be based on an assessment of the risk to persons in outby areas, considering the following factors: proximity to seals; proximity to potential fire or ignition sources; conditions in the outby areas; location of stored SCSRs; and proximity to the most direct, safe, and practical route to an intake escapeway.\n\n(d) Roof and rib support for refuge alternative locations shall be specified in the mine's roof control plan.\n\n(e) The operator shall protect the refuge alternative and contents from damage during transportation, installation, and storage.\n\n(f) A refuge alternative shall be removed from service if examination reveals damage that interferes with the functioning of the refuge alternative or any component.\n\n(1) If a refuge alternative is removed from service, the operator shall withdraw all persons from the area serviced by the refuge alternative, except those persons referred to in § 104(c) of the Mine Act.\n\n(2) Refuge alternative components removed from service shall be replaced or be repaired for return to service in accordance with the manufacturer's specifications.\n\n(g) At all times, the site and area around the refuge alternative shall be kept clear of machinery, materials, and obstructions that could interfere with the deployment or use of the refuge alternative.\n\n(h) Each refuge alternative shall be conspicuously identified with a sign or marker as follows:\n\n(1) A sign or marker made of a reflective material with the word “REFUGE” shall be posted conspicuously at each refuge alternative.\n\n(2) Directional signs made of a reflective material shall be posted leading to each refuge alternative location.\n\n(i) During use of the refuge alternative, the atmosphere within the refuge alternative shall be monitored. Changes or adjustments shall be made to reduce the concentration of methane to less than 1 percent; to reduce the concentration of carbon dioxide to 1 percent or less and excursions not exceeding 2.5 percent; and to reduce the concentration of carbon monoxide to 25 ppm or less. Oxygen shall be maintained at 18.5 to 23 percent.\n\n(j) Refuge alternatives shall contain a fire extinguisher that—\n\n(1) Meets the requirements for portable fire extinguishers used in underground coal mines under this part;\n\n(2) Is appropriate for extinguishing fires involving the chemicals used for harmful gas removal; and\n\n(3) Uses a low-toxicity extinguishing agent that does not produce a hazardous by-product when activated.\n\n[73 FR 80698, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1725","heading":"Machinery and equipment; operation and maintenance.","id":"75.1725","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1725","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.604","heading":"Permanent splicing of trailing cables.","id":"75.604","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.604","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"[Statutory Provisions]\n\nWhen permanent splices in trailing cables are made, they shall be:\n\n(a) Mechanically strong with adequate electrical conductivity and flexibility;\n\n(b) Effectively insulated and sealed so as to exclude moisture; and\n\n(c) Vulcanized or otherwise treated with suitable materials to provide flame-resistant qualities and good bonding to the outer jacket.\n\n(d) Made using splice kits accepted or approved by MSHA as flame resistant.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 57 FR 61223, Dec. 23, 1992]","occurrenceCount":2},{"chapter":"I","heading":"Fire suppression devices.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107","part":"75","subchapter":"O","subpart":"L","id":"75.1107","citation":"30 CFR 75.1107","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4608553","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}