{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"4608387","name":"Laurel Creek/Spirit Mine","status":"Abandoned and Sealed","status_date":"2012-05-16","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Boone","nearest_town":"Madison","operator_id":"P23835","operator_name":"Spartan Mining Company","controller_id":"0127321","controller_name":"Alpha Metallurgical Resources Inc","district":"C04","office":"Madison WV Field Office","employees":0,"latitude":38.051388,"longitude":-81.709722},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":2540},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4608387","name":"Laurel Creek/Spirit Mine"},"operator":{"type":"operator","id":"P23835","name":"Spartan Mining Company"},"controller":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"mine","id":"4608387","name":"Laurel Creek/Spirit Mine"},"validFrom":"1974-01-01","validTo":"2011-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608387|C02508|1974-01-01|2011-05-31"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P11051","name":"Elk Run Coal Company Inc"},"object":{"type":"mine","id":"4608387","name":"Laurel Creek/Spirit Mine"},"validFrom":"1994-01-01","validTo":"2004-02-17","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608387|P11051|1994-01-01|2004-02-17"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"P11051","name":"Elk Run Coal Company Inc"},"validFrom":"1994-01-01","validTo":"2004-02-17","current":false,"derived":true,"evidenceMineId":"4608387","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608387|P11051|1994-01-01|C02508|1974-01-01|58991"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"mine","id":"4608387","name":"Laurel Creek/Spirit Mine"},"validFrom":"1996-02-05","validTo":"2011-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608387|C02508|1996-02-05|2011-05-31"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C03666","name":"Ronald G  Goff"},"object":{"type":"mine","id":"4608387","name":"Laurel Creek/Spirit Mine"},"validFrom":"2000-05-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608387|C03666|2000-05-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23835","name":"Spartan Mining Company"},"object":{"type":"mine","id":"4608387","name":"Laurel Creek/Spirit Mine"},"validFrom":"2004-02-18","validTo":"2004-09-26","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608387|P23835|2004-02-18|2004-09-26"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"P23835","name":"Spartan Mining Company"},"validFrom":"2004-02-18","validTo":"2004-09-26","current":false,"derived":true,"evidenceMineId":"4608387","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608387|P23835|2004-02-18|C02508|1996-02-05|59439"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24399","name":"RAMA Development Co., Inc."},"object":{"type":"mine","id":"4608387","name":"Laurel Creek/Spirit Mine"},"validFrom":"2004-09-27","validTo":"2004-11-07","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608387|P24399|2004-09-27|2004-11-07"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C03666","name":"Ronald G  Goff"},"object":{"type":"operator","id":"P24399","name":"RAMA Development Co., Inc."},"validFrom":"2004-09-27","validTo":"2004-11-07","current":false,"derived":true,"evidenceMineId":"4608387","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608387|P24399|2004-09-27|C03666|2000-05-01|63527"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23835","name":"Spartan Mining Company"},"object":{"type":"mine","id":"4608387","name":"Laurel Creek/Spirit Mine"},"validFrom":"2004-11-08","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608387|P23835|2004-11-08|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"P23835","name":"Spartan Mining Company"},"validFrom":"2004-11-08","validTo":"2011-05-31","current":false,"derived":true,"evidenceMineId":"4608387","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608387|P23835|2004-11-08|C02508|1996-02-05|59440"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"4608387","name":"Laurel Creek/Spirit Mine"},"validFrom":"2011-06-01","validTo":"2016-07-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608387|0041211|2011-06-01|2016-07-25"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P11051","name":"Elk Run Coal Company Inc"},"validFrom":"2011-06-01","validTo":"2004-02-17","current":false,"derived":true,"evidenceMineId":"4608387","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608387|P11051|1994-01-01|0041211|2011-06-01|2089"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P23835","name":"Spartan Mining Company"},"validFrom":"2011-06-01","validTo":"2004-09-26","current":false,"derived":true,"evidenceMineId":"4608387","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608387|P23835|2004-02-18|0041211|2011-06-01|2090"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P23835","name":"Spartan Mining Company"},"validFrom":"2011-06-01","validTo":"2016-07-25","current":false,"derived":true,"evidenceMineId":"4608387","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608387|P23835|2004-11-08|0041211|2011-06-01|2091"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"mine","id":"4608387","name":"Laurel Creek/Spirit Mine"},"validFrom":"2016-07-26","validTo":"2018-11-08","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608387|0127923|2016-07-26|2018-11-08"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"operator","id":"P11051","name":"Elk Run Coal Company Inc"},"validFrom":"2016-07-26","validTo":"2004-02-17","current":false,"derived":true,"evidenceMineId":"4608387","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608387|P11051|1994-01-01|0127923|2016-07-26|25209"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"operator","id":"P23835","name":"Spartan Mining Company"},"validFrom":"2016-07-26","validTo":"2004-09-26","current":false,"derived":true,"evidenceMineId":"4608387","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608387|P23835|2004-02-18|0127923|2016-07-26|25210"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"operator","id":"P23835","name":"Spartan Mining Company"},"validFrom":"2016-07-26","validTo":"2018-11-08","current":false,"derived":true,"evidenceMineId":"4608387","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608387|P23835|2004-11-08|0127923|2016-07-26|25211"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"mine","id":"4608387","name":"Laurel Creek/Spirit Mine"},"validFrom":"2018-11-09","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608387|0127321|2018-11-09|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"operator","id":"P11051","name":"Elk Run Coal Company Inc"},"validFrom":"2018-11-09","validTo":"2004-02-17","current":false,"derived":true,"evidenceMineId":"4608387","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608387|P11051|1994-01-01|0127321|2018-11-09|24844"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"operator","id":"P23835","name":"Spartan Mining Company"},"validFrom":"2018-11-09","validTo":"2004-09-26","current":false,"derived":true,"evidenceMineId":"4608387","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608387|P23835|2004-02-18|0127321|2018-11-09|24845"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"operator","id":"P23835","name":"Spartan Mining Company"},"validFrom":"2018-11-09","validTo":null,"current":true,"derived":true,"evidenceMineId":"4608387","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4608387|P23835|2004-11-08|0127321|2018-11-09|24846"}}],"coverage":{"historyRecords":13,"edgeCount":23,"intervalAnomalies":6,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":30,"firstDate":"2005-01-10","lastDate":"2008-06-11","metrics":{"daysLost":971,"injuries":26,"fatalities":0,"recentRows":0,"restrictedDays":132,"contractorRecords":1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"132599","DOCUMENT_NO":"220081960026","ACCIDENT_DT":"06/11/2008","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Member was helping to change pick breaker in feeder, on end dropped mashing his left index finger resulting in a fracture. Member did not report this to mine management until 7-7-2008","sourceDate":"2008-06-11"},{"SOURCE_ROW_NUMBER":"218867","DOCUMENT_NO":"220081560035","ACCIDENT_DT":"05/17/2008","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Member was helping to install timbers to recover a MRS support, As he was lifting timbers he felt a pain in his back, MRI was preformed on 5-27-08 and he was placed on restricted duty on 6-2-08","sourceDate":"2008-05-17"},{"SOURCE_ROW_NUMBER":"98196","DOCUMENT_NO":"220081340024","ACCIDENT_DT":"05/09/2008","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Walking along belt line, his utility knife hanging on side of his belt with blade open, caught him in the palm causing a laceration requiring 3 stiches. He returned his next shift to work.","sourceDate":"2008-05-09"},{"SOURCE_ROW_NUMBER":"236103","DOCUMENT_NO":"220081140038","ACCIDENT_DT":"04/18/2008","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE had finished moving miner into # 5 face for next cut, after pulling into face and backing up 4' to 5' he shut off the miner and walked along side of miner, after that he restarted miner and was taking pull ropes off cable, as he bent over he must have hit the boom swing lever causing boom the mash him against rib resulting in fracture to 4 ribs on right side","sourceDate":"2008-04-18"},{"SOURCE_ROW_NUMBER":"180127","DOCUMENT_NO":"220073540025","ACCIDENT_DT":"12/18/2007","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"After putting oil into miner member was throwing empty oil cans into scoop, the handle on the can can loose caughting his right middle finger causing a laceration requiring stiches","sourceDate":"2007-12-18"},{"SOURCE_ROW_NUMBER":"51019","DOCUMENT_NO":"220080220055","ACCIDENT_DT":"12/12/2007","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"A accident reportt #544343 was sumitted on employement. Laceration on right middle finger, After putting oil into a miner, he throw the can into a scoop bucket. Handle can loose on can, cutting his right midle finger. On 1-14-2008 he was place on restricted duty due to staff infection to his finger.","sourceDate":"2007-12-12"},{"SOURCE_ROW_NUMBER":"184425","DOCUMENT_NO":"220072950075","ACCIDENT_DT":"10/15/2007","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Roof fall, 2A belt #5 entry spad #1851. Size of fall: Length 20 ft, width 20 ft, Height 5 ft.","sourceDate":"2007-10-15"},{"SOURCE_ROW_NUMBER":"227457","DOCUMENT_NO":"220072640037","ACCIDENT_DT":"09/15/2007","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by powered moving object","OCCUPATION":"Motorman, Motor person, Swamper, Switchman, Locomotive operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE was tramming scoop through a mud hole. A scraper was in the mud hole. EE did not see it, scraper came up and hit him in the right shoulder.","sourceDate":"2007-09-15"},{"SOURCE_ROW_NUMBER":"175848","DOCUMENT_NO":"220072470052","ACCIDENT_DT":"08/28/2007","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Member was pushing roof bolts off of the scoop onto the roof bolter when the bundle of roof bolts fell pinning members left pinky finger under the roof bolts.","sourceDate":"2007-08-28"},{"SOURCE_ROW_NUMBER":"158616","DOCUMENT_NO":"220071830092","ACCIDENT_DT":"06/21/2007","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Motorman, Motor person, Swamper, Switchman, Locomotive operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Member was reaching in his pocket and cut his left index finger on his belt knife.","sourceDate":"2007-06-21"},{"SOURCE_ROW_NUMBER":"240418","DOCUMENT_NO":"220070030028","ACCIDENT_DT":"12/19/2006","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was walking to the end of the track when he stepped in a hole causing his ankle to twist. X-rays revealed a fracture to his left ankle. He was unable to perform his normal job, so he was placed on restricted duty.","sourceDate":"2006-12-19"},{"SOURCE_ROW_NUMBER":"218866","DOCUMENT_NO":"220062790024","ACCIDENT_DT":"09/26/2006","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Member was drilling first hole in the #1 entry. A rock fell above canopy and broke, a piece of the rock slid down the drill steel, stricking his left forearm. He was transported to Boone Memorial Hospital, where he received 17 stitches.","sourceDate":"2006-09-26"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2012-05-16","lastDate":"2012-05-16","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":622,"firstDate":"2004-12-13","lastDate":"2008-09-08","metrics":{"ss":221,"delinquent":621,"recentRows":0,"paidPenalty":645901,"proposedPenalty":1198128,"currentAssessment":645901},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"851622","VIOLATION_NO":"6619889","ISSUE_DT":"09/08/2008","CFR_STANDARD_CD":"75.311(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-09-08"},{"SOURCE_ROW_NUMBER":"859049","VIOLATION_NO":"6622404","ISSUE_DT":"06/16/2008","CFR_STANDARD_CD":"75.508","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"117.00","CURRENT_ASSESSMENT_AMT":"117.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-06-16"},{"SOURCE_ROW_NUMBER":"859048","VIOLATION_NO":"6622403","ISSUE_DT":"06/16/2008","CFR_STANDARD_CD":"77.403-1(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-06-16"},{"SOURCE_ROW_NUMBER":"859055","VIOLATION_NO":"6623526","ISSUE_DT":"06/12/2008","CFR_STANDARD_CD":"75.1505(a)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"460.00","CURRENT_ASSESSMENT_AMT":"230.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-06-12"},{"SOURCE_ROW_NUMBER":"859054","VIOLATION_NO":"6623525","ISSUE_DT":"06/12/2008","CFR_STANDARD_CD":"75.360(f)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1530.00","CURRENT_ASSESSMENT_AMT":"300.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-06-12"},{"SOURCE_ROW_NUMBER":"859053","VIOLATION_NO":"6623524","ISSUE_DT":"06/11/2008","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"176.00","CURRENT_ASSESSMENT_AMT":"176.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-06-11"},{"SOURCE_ROW_NUMBER":"859052","VIOLATION_NO":"6623523","ISSUE_DT":"06/10/2008","CFR_STANDARD_CD":"75.1100-2(e)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"117.00","CURRENT_ASSESSMENT_AMT":"117.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-06-10"},{"SOURCE_ROW_NUMBER":"859051","VIOLATION_NO":"6623522","ISSUE_DT":"06/10/2008","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"460.00","CURRENT_ASSESSMENT_AMT":"230.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-06-10"},{"SOURCE_ROW_NUMBER":"859050","VIOLATION_NO":"6623521","ISSUE_DT":"06/10/2008","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"585.00","CURRENT_ASSESSMENT_AMT":"585.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-06-10"},{"SOURCE_ROW_NUMBER":"859047","VIOLATION_NO":"6622402","ISSUE_DT":"06/04/2008","CFR_STANDARD_CD":"75.333(g)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"117.00","CURRENT_ASSESSMENT_AMT":"117.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-06-04"},{"SOURCE_ROW_NUMBER":"859070","VIOLATION_NO":"7152731","ISSUE_DT":"06/03/2008","CFR_STANDARD_CD":"75.1100-2(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-06-03"},{"SOURCE_ROW_NUMBER":"859069","VIOLATION_NO":"7152730","ISSUE_DT":"06/03/2008","CFR_STANDARD_CD":"75.1722(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"585.00","CURRENT_ASSESSMENT_AMT":"585.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-06-03"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":185,"firstDate":"2008-04-17","lastDate":"2012-03-07","metrics":{"appeals":0,"decisions":185,"recentRows":0,"decisionPenalty":565270,"originalPenalty":1117652},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"274444","VIOLATION_NO":"7280618","DOCKET_NO":"WEVA 2008-1259","DECISION_DT":"03/07/2012","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"5600.00","DECISION_PENALTY_AMT":"5600.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2012-03-07"},{"SOURCE_ROW_NUMBER":"255638","VIOLATION_NO":"6601534","DOCKET_NO":"WEVA 2007-664","DECISION_DT":"03/23/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"60.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2011-03-23"},{"SOURCE_ROW_NUMBER":"253122","VIOLATION_NO":"7458075","DOCKET_NO":"WEVA 2007-663","DECISION_DT":"03/23/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"723.00","DECISION_PENALTY_AMT":"506.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2011-03-23"},{"SOURCE_ROW_NUMBER":"253121","VIOLATION_NO":"7458070","DOCKET_NO":"WEVA 2007-663","DECISION_DT":"03/23/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"191.00","DECISION_PENALTY_AMT":"133.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2011-03-23"},{"SOURCE_ROW_NUMBER":"253120","VIOLATION_NO":"7062302","DOCKET_NO":"WEVA 2007-663","DECISION_DT":"03/23/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"191.00","DECISION_PENALTY_AMT":"191.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2011-03-23"},{"SOURCE_ROW_NUMBER":"253119","VIOLATION_NO":"7062297","DOCKET_NO":"WEVA 2007-663","DECISION_DT":"03/23/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"228.00","DECISION_PENALTY_AMT":"228.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2011-03-23"},{"SOURCE_ROW_NUMBER":"252884","VIOLATION_NO":"7458067","DOCKET_NO":"WEVA 2007-663","DECISION_DT":"03/23/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"247.00","DECISION_PENALTY_AMT":"247.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2011-03-23"},{"SOURCE_ROW_NUMBER":"252883","VIOLATION_NO":"6601523","DOCKET_NO":"WEVA 2007-663","DECISION_DT":"03/23/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"191.00","DECISION_PENALTY_AMT":"133.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2011-03-23"},{"SOURCE_ROW_NUMBER":"252755","VIOLATION_NO":"7458069","DOCKET_NO":"WEVA 2007-663","DECISION_DT":"03/23/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"191.00","DECISION_PENALTY_AMT":"191.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2011-03-23"},{"SOURCE_ROW_NUMBER":"252735","VIOLATION_NO":"7458074","DOCKET_NO":"WEVA 2007-663","DECISION_DT":"03/23/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"350.00","DECISION_PENALTY_AMT":"175.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2011-03-23"},{"SOURCE_ROW_NUMBER":"252734","VIOLATION_NO":"6601515","DOCKET_NO":"WEVA 2007-663","DECISION_DT":"03/23/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"191.00","DECISION_PENALTY_AMT":"191.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2011-03-23"},{"SOURCE_ROW_NUMBER":"14512","VIOLATION_NO":"6601519","DOCKET_NO":"WEVA 2007-664","DECISION_DT":"03/23/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"60.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2011-03-23"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":380,"firstDate":"2000-05-06","lastDate":"2009-09-26","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":37,"validSamples":343,"maxConcentration":4.395,"concentrationTotal":180.242},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1606486","CASS_NUM":"50774757","SMP_TAKEN_DT":"9/26/2009","CONC":".093","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"PREDATED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-09-26"},{"SOURCE_ROW_NUMBER":"1421846","CASS_NUM":"57706605","SMP_TAKEN_DT":"6/17/2008","CONC":".06","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-06-17"},{"SOURCE_ROW_NUMBER":"1265726","CASS_NUM":"57706593","SMP_TAKEN_DT":"6/17/2008","CONC":".12","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-06-17"},{"SOURCE_ROW_NUMBER":"1016781","CASS_NUM":"57706583","SMP_TAKEN_DT":"6/17/2008","CONC":".692","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-06-17"},{"SOURCE_ROW_NUMBER":"799916","CASS_NUM":"57706599","SMP_TAKEN_DT":"6/17/2008","CONC":".33","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-06-17"},{"SOURCE_ROW_NUMBER":"730807","CASS_NUM":"57706614","SMP_TAKEN_DT":"6/17/2008","CONC":".231","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-06-17"},{"SOURCE_ROW_NUMBER":"477611","CASS_NUM":"57706596","SMP_TAKEN_DT":"6/17/2008","CONC":".263","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SECTION FOREMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-06-17"},{"SOURCE_ROW_NUMBER":"172314","CASS_NUM":"57706611","SMP_TAKEN_DT":"6/17/2008","CONC":".149","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-06-17"},{"SOURCE_ROW_NUMBER":"1178387","CASS_NUM":"50791932","SMP_TAKEN_DT":"5/21/2008","CONC":".181","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-05-21"},{"SOURCE_ROW_NUMBER":"947959","CASS_NUM":"50791938","SMP_TAKEN_DT":"5/7/2008","CONC":".152","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-05-07"},{"SOURCE_ROW_NUMBER":"263184","CASS_NUM":"50787803","SMP_TAKEN_DT":"5/7/2008","CONC":".081","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-05-07"},{"SOURCE_ROW_NUMBER":"203337","CASS_NUM":"50806428","SMP_TAKEN_DT":"5/6/2008","CONC":".115","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-05-06"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":18,"firstDate":"2005-03-31","lastDate":"2006-11-30","metrics":{"linkedIssuances":18},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":185,"firstDate":"2006-05-15","lastDate":"2008-06-12","metrics":{"decisions":185,"ssChanged":40,"recentRows":0,"decisionPenalty":565270,"proposedPenalty":1117652},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"405537","CITATION_NO":"6623526","CITATION_ISSUE_DT":"06/12/2008","DOCKET_NO":"WEVA 2008-1846","DECISION_DT":"09/29/2009","CFR_STANDARD_CODE":"75.1505(a)(3)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"460.00","DECISION_PENALTY_AMT":"230.00","sourceDate":"2008-06-12"},{"SOURCE_ROW_NUMBER":"122715","CITATION_NO":"6623525","CITATION_ISSUE_DT":"06/12/2008","DOCKET_NO":"WEVA 2008-1845","DECISION_DT":"09/10/2009","CFR_STANDARD_CODE":"75.360(f)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1530.00","DECISION_PENALTY_AMT":"300.00","sourceDate":"2008-06-12"},{"SOURCE_ROW_NUMBER":"10273","CITATION_NO":"6623524","CITATION_ISSUE_DT":"06/11/2008","DOCKET_NO":"WEVA 2008-1846","DECISION_DT":"09/29/2009","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"176.00","DECISION_PENALTY_AMT":"176.00","sourceDate":"2008-06-11"},{"SOURCE_ROW_NUMBER":"406198","CITATION_NO":"6623522","CITATION_ISSUE_DT":"06/10/2008","DOCKET_NO":"WEVA 2008-1846","DECISION_DT":"09/29/2009","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"460.00","DECISION_PENALTY_AMT":"230.00","sourceDate":"2008-06-10"},{"SOURCE_ROW_NUMBER":"348473","CITATION_NO":"7152721","CITATION_ISSUE_DT":"05/30/2008","DOCKET_NO":"WEVA 2008-1845","DECISION_DT":"09/10/2009","CFR_STANDARD_CODE":"77.208(e)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"200.00","sourceDate":"2008-05-30"},{"SOURCE_ROW_NUMBER":"292898","CITATION_NO":"7152723","CITATION_ISSUE_DT":"05/30/2008","DOCKET_NO":"WEVA 2008-1845","DECISION_DT":"09/10/2009","CFR_STANDARD_CODE":"75.203(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"200.00","sourceDate":"2008-05-30"},{"SOURCE_ROW_NUMBER":"235435","CITATION_NO":"7152724","CITATION_ISSUE_DT":"05/30/2008","DOCKET_NO":"WEVA 2008-1845","DECISION_DT":"09/10/2009","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"500.00","sourceDate":"2008-05-30"},{"SOURCE_ROW_NUMBER":"10509","CITATION_NO":"7152722","CITATION_ISSUE_DT":"05/30/2008","DOCKET_NO":"WEVA 2008-1845","DECISION_DT":"09/10/2009","CFR_STANDARD_CODE":"77.400(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"500.00","sourceDate":"2008-05-30"},{"SOURCE_ROW_NUMBER":"292182","CITATION_NO":"7152697","CITATION_ISSUE_DT":"04/22/2008","DOCKET_NO":"WEVA 2008-1845","DECISION_DT":"09/10/2009","CFR_STANDARD_CODE":"72.630(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"745.00","DECISION_PENALTY_AMT":"745.00","sourceDate":"2008-04-22"},{"SOURCE_ROW_NUMBER":"181012","CITATION_NO":"7152698","CITATION_ISSUE_DT":"04/22/2008","DOCKET_NO":"WEVA 2008-1845","DECISION_DT":"09/10/2009","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2282.00","DECISION_PENALTY_AMT":"1100.00","sourceDate":"2008-04-22"},{"SOURCE_ROW_NUMBER":"289215","CITATION_NO":"7280703","CITATION_ISSUE_DT":"02/09/2008","DOCKET_NO":"WEVA 2008-1640","DECISION_DT":"07/16/2009","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":"250.00","sourceDate":"2008-02-09"},{"SOURCE_ROW_NUMBER":"288604","CITATION_NO":"7280702","CITATION_ISSUE_DT":"02/08/2008","DOCKET_NO":"WEVA 2008-1640","DECISION_DT":"07/16/2009","CFR_STANDARD_CODE":"75.364(a)(2)(iii)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":"250.00","sourceDate":"2008-02-08"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":338,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":52,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":13,"firstDate":"1994-01-01","lastDate":"2004-11-08","metrics":{"recentRows":0,"currentOperatorTenures":4,"completedOperatorTenures":9},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":24,"firstDate":"2004-03-15","lastDate":"2008-09-08","metrics":{"inspectors":53,"recentRows":0,"onSiteHours":1973.5,"inspectionHours":2931.5,"inspectionSamples":196},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"443545","EVENT_NO":"4120185","INSPECTION_BEGIN_DT":"09/08/2008","INSPECTION_END_DT":"09/11/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"17.5","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2008-09-08"},{"SOURCE_ROW_NUMBER":"61329","EVENT_NO":"4118678","INSPECTION_BEGIN_DT":"08/07/2008","INSPECTION_END_DT":"08/07/2008","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"1.25","sourceDate":"2008-08-07"},{"SOURCE_ROW_NUMBER":"730342","EVENT_NO":"4121219","INSPECTION_BEGIN_DT":"04/01/2008","INSPECTION_END_DT":"06/25/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"185.25","SUM_TOTAL_ON_SITE_HOURS":"109.25","sourceDate":"2008-04-01"},{"SOURCE_ROW_NUMBER":"679941","EVENT_NO":"4120162","INSPECTION_BEGIN_DT":"01/04/2008","INSPECTION_END_DT":"02/25/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"208","SUM_TOTAL_ON_SITE_HOURS":"142","sourceDate":"2008-01-04"},{"SOURCE_ROW_NUMBER":"1026353","EVENT_NO":"4116950","INSPECTION_BEGIN_DT":"10/15/2007","INSPECTION_END_DT":"10/18/2007","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"8.5","sourceDate":"2007-10-15"},{"SOURCE_ROW_NUMBER":"541835","EVENT_NO":"4116948","INSPECTION_BEGIN_DT":"10/02/2007","INSPECTION_END_DT":"11/09/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"315.5","SUM_TOTAL_ON_SITE_HOURS":"211","sourceDate":"2007-10-02"},{"SOURCE_ROW_NUMBER":"752392","EVENT_NO":"4112995","INSPECTION_BEGIN_DT":"06/27/2007","INSPECTION_END_DT":"09/27/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"79.75","SUM_TOTAL_ON_SITE_HOURS":"62","sourceDate":"2007-06-27"},{"SOURCE_ROW_NUMBER":"283665","EVENT_NO":"4112985","INSPECTION_BEGIN_DT":"04/02/2007","INSPECTION_END_DT":"06/04/2007","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"130.25","SUM_TOTAL_ON_SITE_HOURS":"99.75","sourceDate":"2007-04-02"},{"SOURCE_ROW_NUMBER":"257708","EVENT_NO":"4115826","INSPECTION_BEGIN_DT":"01/30/2007","INSPECTION_END_DT":"02/05/2007","ACTIVITY_CODE":"E03","ACTIVITY":"103 (g) Written Notification Hazard Complaint Inspectio","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"17","SUM_TOTAL_ON_SITE_HOURS":"9.5","sourceDate":"2007-01-30"},{"SOURCE_ROW_NUMBER":"654848","EVENT_NO":"4115825","INSPECTION_BEGIN_DT":"01/22/2007","INSPECTION_END_DT":"03/26/2007","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"70.5","SUM_TOTAL_ON_SITE_HOURS":"38.25","sourceDate":"2007-01-22"},{"SOURCE_ROW_NUMBER":"618526","EVENT_NO":"4115808","INSPECTION_BEGIN_DT":"10/16/2006","INSPECTION_END_DT":"01/11/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"108.5","SUM_TOTAL_ON_SITE_HOURS":"68.75","sourceDate":"2006-10-16"},{"SOURCE_ROW_NUMBER":"879526","EVENT_NO":"4112947","INSPECTION_BEGIN_DT":"07/24/2006","INSPECTION_END_DT":"08/07/2006","ACTIVITY_CODE":"E33","ACTIVITY":"Non-Chargeable Accident Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2006-07-24"}]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":8,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2005":{"hours":165213,"employees":69,"production":906875},"2006":{"hours":185161,"employees":76,"production":1002239},"2007":{"hours":177573,"employees":73,"production":1039692},"2008":{"hours":72106,"employees":47,"production":300372}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":26,"firstDate":"2005-09-29","lastDate":"2007-11-09","metrics":{"recentRows":0,"doseOver100":3,"actDoseTotal":1471,"pelDoseTotal":1017},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"237388","EVENT_NO":"4116948","SURVEY_DATE":"11/09/2007","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"48","PEL_DOSE_90":"26","SURVEY_TYPE":"I","sourceDate":"2007-11-09"},{"SOURCE_ROW_NUMBER":"237387","EVENT_NO":"4116948","SURVEY_DATE":"11/09/2007","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"57","PEL_DOSE_90":"35","SURVEY_TYPE":"I","sourceDate":"2007-11-09"},{"SOURCE_ROW_NUMBER":"237386","EVENT_NO":"4116948","SURVEY_DATE":"11/09/2007","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"77","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2007-11-09"},{"SOURCE_ROW_NUMBER":"237385","EVENT_NO":"4116948","SURVEY_DATE":"11/09/2007","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"115","PEL_DOSE_90":"90","SURVEY_TYPE":"I","sourceDate":"2007-11-09"},{"SOURCE_ROW_NUMBER":"237384","EVENT_NO":"4116948","SURVEY_DATE":"11/09/2007","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"107","PEL_DOSE_90":"92","SURVEY_TYPE":"I","sourceDate":"2007-11-09"},{"SOURCE_ROW_NUMBER":"237378","EVENT_NO":"4112964","SURVEY_DATE":"09/11/2006","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"53","PEL_DOSE_90":"28","SURVEY_TYPE":"I","sourceDate":"2006-09-11"},{"SOURCE_ROW_NUMBER":"237377","EVENT_NO":"4112964","SURVEY_DATE":"09/11/2006","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"61","PEL_DOSE_90":"41","SURVEY_TYPE":"I","sourceDate":"2006-09-11"},{"SOURCE_ROW_NUMBER":"237376","EVENT_NO":"4112964","SURVEY_DATE":"09/11/2006","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"57","PEL_DOSE_90":"42","SURVEY_TYPE":"I","sourceDate":"2006-09-11"},{"SOURCE_ROW_NUMBER":"237375","EVENT_NO":"4112964","SURVEY_DATE":"09/11/2006","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"39","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2006-09-11"},{"SOURCE_ROW_NUMBER":"237374","EVENT_NO":"4112964","SURVEY_DATE":"09/11/2006","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"118","PEL_DOSE_90":"105","SURVEY_TYPE":"I","sourceDate":"2006-09-11"},{"SOURCE_ROW_NUMBER":"237383","EVENT_NO":"4112964","SURVEY_DATE":"09/06/2006","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"37","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2006-09-06"},{"SOURCE_ROW_NUMBER":"237382","EVENT_NO":"4112964","SURVEY_DATE":"09/06/2006","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"63","PEL_DOSE_90":"40","SURVEY_TYPE":"I","sourceDate":"2006-09-06"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":18,"firstDate":"2004-12-28","lastDate":"2008-01-28","metrics":{"recentRows":0,"voidSamples":3,"maxQuartzPct":27,"validSamples":15,"quartzPctTotal":182.8},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"8294","CASSETTE_NO":"57633149","SAMPLE_DT":"01/28/2008","QUARTZ_PCT":"13.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-01-28"},{"SOURCE_ROW_NUMBER":"123736","CASSETTE_NO":"57637826","SAMPLE_DT":"10/29/2007","QUARTZ_PCT":"04.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-10-29"},{"SOURCE_ROW_NUMBER":"142632","CASSETTE_NO":"50790180","SAMPLE_DT":"11/08/2006","QUARTZ_PCT":"20.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-11-08"},{"SOURCE_ROW_NUMBER":"73175","CASSETTE_NO":"57618987","SAMPLE_DT":"10/25/2006","QUARTZ_PCT":"13.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-10-25"},{"SOURCE_ROW_NUMBER":"54241","CASSETTE_NO":"57619068","SAMPLE_DT":"08/23/2006","QUARTZ_PCT":"11.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-08-23"},{"SOURCE_ROW_NUMBER":"125731","CASSETTE_NO":"57619184","SAMPLE_DT":"08/22/2006","QUARTZ_PCT":"08.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-08-22"},{"SOURCE_ROW_NUMBER":"122138","CASSETTE_NO":"57619181","SAMPLE_DT":"08/21/2006","QUARTZ_PCT":"09.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-08-21"},{"SOURCE_ROW_NUMBER":"957","CASSETTE_NO":"57637514","SAMPLE_DT":"05/09/2006","QUARTZ_PCT":"07.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-05-09"},{"SOURCE_ROW_NUMBER":"10262","CASSETTE_NO":"50756779","SAMPLE_DT":"11/01/2005","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2005-11-01"},{"SOURCE_ROW_NUMBER":"119563","CASSETTE_NO":"57568397","SAMPLE_DT":"10/17/2005","QUARTZ_PCT":"24.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-10-17"},{"SOURCE_ROW_NUMBER":"39999","CASSETTE_NO":"57504372","SAMPLE_DT":"09/06/2005","QUARTZ_PCT":"04.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-09-06"},{"SOURCE_ROW_NUMBER":"56305","CASSETTE_NO":"50774280","SAMPLE_DT":"08/09/2005","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2005-08-09"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":639,"firstDate":"2004-12-13","lastDate":"2008-09-08","metrics":{"ss":222,"amountDue":645901,"contested":184,"amountPaid":645901,"recentRows":0,"section104d":10,"unterminated":5,"proposedPenalty":1198128},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2719326","VIOLATION_NO":"6619889","VIOLATION_ISSUE_DT":"09/08/2008","SIG_SUB":"N","PART_SECTION":"75.311(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/11/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-09-08"},{"SOURCE_ROW_NUMBER":"2718981","VIOLATION_NO":"6622404","VIOLATION_ISSUE_DT":"06/16/2008","SIG_SUB":"N","PART_SECTION":"75.508","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/16/2008","PROPOSED_PENALTY":"117","AMOUNT_DUE":"117","AMOUNT_PAID":"117","CONTESTED_IND":"N","sourceDate":"2008-06-16"},{"SOURCE_ROW_NUMBER":"2718980","VIOLATION_NO":"6622403","VIOLATION_ISSUE_DT":"06/16/2008","SIG_SUB":"N","PART_SECTION":"77.403-1(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/07/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-06-16"},{"SOURCE_ROW_NUMBER":"2718987","VIOLATION_NO":"6623526","VIOLATION_ISSUE_DT":"06/12/2008","SIG_SUB":"N","PART_SECTION":"75.1505(a)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"10","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/16/2008","PROPOSED_PENALTY":"460","AMOUNT_DUE":"230","AMOUNT_PAID":"230","CONTESTED_IND":"Y","DOCKET_NO":"WEVA 2008-1846","sourceDate":"2008-06-12"},{"SOURCE_ROW_NUMBER":"2718986","VIOLATION_NO":"6623525","VIOLATION_ISSUE_DT":"06/12/2008","SIG_SUB":"N","PART_SECTION":"75.360(f)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"10","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/12/2008","PROPOSED_PENALTY":"1530","AMOUNT_DUE":"300","AMOUNT_PAID":"300","CONTESTED_IND":"Y","DOCKET_NO":"WEVA 2008-1845","sourceDate":"2008-06-12"},{"SOURCE_ROW_NUMBER":"2718985","VIOLATION_NO":"6623524","VIOLATION_ISSUE_DT":"06/11/2008","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/11/2008","PROPOSED_PENALTY":"176","AMOUNT_DUE":"176","AMOUNT_PAID":"176","CONTESTED_IND":"Y","DOCKET_NO":"WEVA 2008-1846","sourceDate":"2008-06-11"},{"SOURCE_ROW_NUMBER":"2718984","VIOLATION_NO":"6623523","VIOLATION_ISSUE_DT":"06/10/2008","SIG_SUB":"N","PART_SECTION":"75.1100-2(e)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/10/2008","PROPOSED_PENALTY":"117","AMOUNT_DUE":"117","AMOUNT_PAID":"117","CONTESTED_IND":"N","sourceDate":"2008-06-10"},{"SOURCE_ROW_NUMBER":"2718983","VIOLATION_NO":"6623522","VIOLATION_ISSUE_DT":"06/10/2008","SIG_SUB":"N","SECTION_OF_ACT":"316(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"10","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/10/2008","PROPOSED_PENALTY":"460","AMOUNT_DUE":"230","AMOUNT_PAID":"230","CONTESTED_IND":"Y","DOCKET_NO":"WEVA 2008-1846","sourceDate":"2008-06-10"},{"SOURCE_ROW_NUMBER":"2718982","VIOLATION_NO":"6623521","VIOLATION_ISSUE_DT":"06/10/2008","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/10/2008","PROPOSED_PENALTY":"585","AMOUNT_DUE":"585","AMOUNT_PAID":"585","CONTESTED_IND":"N","sourceDate":"2008-06-10"},{"SOURCE_ROW_NUMBER":"2718979","VIOLATION_NO":"6622402","VIOLATION_ISSUE_DT":"06/04/2008","SIG_SUB":"N","PART_SECTION":"75.333(g)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/04/2008","PROPOSED_PENALTY":"117","AMOUNT_DUE":"117","AMOUNT_PAID":"117","CONTESTED_IND":"N","sourceDate":"2008-06-04"},{"SOURCE_ROW_NUMBER":"2719002","VIOLATION_NO":"7152731","VIOLATION_ISSUE_DT":"06/03/2008","SIG_SUB":"N","PART_SECTION":"75.1100-2(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/03/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-06-03"},{"SOURCE_ROW_NUMBER":"2719001","VIOLATION_NO":"7152730","VIOLATION_ISSUE_DT":"06/03/2008","SIG_SUB":"Y","PART_SECTION":"75.1722(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/05/2008","PROPOSED_PENALTY":"585","AMOUNT_DUE":"585","AMOUNT_PAID":"585","CONTESTED_IND":"N","sourceDate":"2008-06-03"}]}],"safety":{"href":"/api/v1/mines/4608387/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4608387/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Main mine fan operation.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.311","part":"75","subchapter":"O","subpart":"D","id":"75.311","citation":"30 CFR 75.311","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.508","heading":"Map of electrical system.","id":"75.508","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.508","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe location and the electrical rating of all stationary electric apparatus in connection with the mine electric system, including permanent cables, switchgear, rectifying substations, transformers, permanent pumps, and trolley wires and trolley feeder wires, and settings of all direct-current circuit breakers protecting underground trolley circuits, shall be shown on a mine map. Any changes made in a location, electric rating, or setting shall be promptly shown on the map when the change is made. Such map shall be available to an authorized representative of the Secretary and to the miners in such mine.","occurrenceCount":1},{"chapter":"I","heading":"Mobile equipment; rollover protective structures (ROPS).","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.403-1","part":"77","subchapter":"O","subpart":"E","id":"77.403-1","citation":"30 CFR 77.403-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1505","heading":"Escapeway maps.","id":"75.1505","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-P/section-75.1505","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"P","subpartHeading":"Subpart P—Mine Emergencies","text":"(a) Content and accessibility. An escapeway map shall show the designated escapeways from the working sections or the miners' work stations to the surface or the exits at the bottom of the shaft or slope, refuge alternatives, and SCSR storage locations. The escapeway map shall be posted or readily accessible for all miners—\n\n(1) In each working section;\n\n(2) In each area where mechanized mining equipment is being installed or removed;\n\n(3) At the refuge alternative; and\n\n(4) At a surface location of the mine where miners congregate, such as at the mine bulletin board, bathhouse, or waiting room.\n\n(b) Keeping maps current. All maps shall be kept up-to-date and any change in route of travel, location of doors, location of refuge alternatives, or direction of airflow shall be shown on the maps by the end of the shift on which the change is made.\n\n(c) Informing affected miners. Miners underground on a shift when any such change is made shall be notified immediately of the change and other affected miners shall be informed of the change before entering the underground areas of the mine.\n\n[71 FR 71452, Dec. 8, 2006, as amended at 73 FR 80698, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.360","heading":"Preshift examination at fixed intervals.","id":"75.360","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.360","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) Except as provided in paragraph (a)(2) of this section, a certified person designated by the operator must make a preshift examination within 3 hours preceding the beginning of any 8-hour interval during which any person is scheduled to work or travel underground. No person other than certified examiners may enter or remain in any underground area unless a preshift examination has been completed for the established 8-hour interval. The operator must establish 8-hour intervals of time subject to the required preshift examinations.\n\n(2) Preshift examinations of areas where pumpers are scheduled to work or travel shall not be required prior to the pumper entering the areas if the pumper is a certified person and the pumper conducts an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, tests for methane and oxygen deficiency, and determines if the air is moving in its proper direction in the area where the pumper works or travels. The examination of the area must be completed before the pumper performs any other work. A record of all hazardous conditions and violations of the mandatory health or safety standards found by the pumper shall be made and retained in accordance with § 75.363 of this part.\n\n(b) The person conducting the preshift examination shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction at the following locations:\n\n(1) Roadways, travelways and track haulageways where persons are scheduled, prior to the beginning of the preshift examination, to work or travel during the oncoming shift.\n\n(2) Belt conveyors that will be used to transport persons during the oncoming shift and the entries in which these belt conveyors are located.\n\n(3) Working sections and areas where mechanized mining equipment is being installed or removed, if anyone is scheduled to work on the section or in the area during the oncoming shift. The scope of the examination shall include the working places, approaches to worked-out areas and ventilation controls on these sections and in these areas, and the examination shall include tests of the roof, face and rib conditions on these sections and in these areas.\n\n(4) Approaches to worked-out areas along intake air courses and at the entries used to carry air into worked-out areas if the intake air passing the approaches is used to ventilate working sections where anyone is scheduled to work during the oncoming shift. The examination of the approaches to the worked-out areas shall be made in the intake air course immediately inby and outby each entry used to carry air into the worked-out area. An examination of the entries used to carry air into the worked-out areas shall be conducted at a point immediately inby the intersection of each entry with the intake air course.\n\n(5) Seals along intake air courses where intake air passes by a seal to ventilate working sections where anyone is scheduled to work during the oncoming shift.\n\n(6)(i) Entries and rooms developed after November 15, 1992, and developed more than 2 crosscuts off an intake air course without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift; and,\n\n(ii) Entries and rooms developed after November 15, 1992, and driven more than 20 feet off an intake air course without a crosscut and without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift.\n\n(7) Areas where trolley wires or trolley feeder wires are to be or will remain energized during the oncoming shift.\n\n(8) High spots along intake air courses where methane is likely to accumulate, if equipment will be operated in the area during the shift.\n\n(9) Underground electrical installations referred to in § 75.340(a), except those pumps listed in § 75.340 (b)(2) through (b)(6), and areas where compressors subject to § 75.344 are installed if the electrical installation or compressor is or will be energized during the shift.\n\n(10) Other areas where work or travel during the oncoming shift is scheduled prior to the beginning of the preshift examination.\n\n(11) Preshift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) The person conducting the preshift examination shall determine the volume of air entering each of the following areas if anyone is scheduled to work in the areas during the oncoming shift:\n\n(1) In the last open crosscut of each set of entries or rooms on each working section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) On each longwall or shortwall in the intake entry or entries at the intake end of the longwall or shortwall face immediately outby the face and the velocity of air at each end of the face at the locations specified in the approved ventilation plan.\n\n(3) At the intake end of any pillar line—\n\n(i) If a single split of air is used, in the intake entry furthest from the return air course, immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) If a split system is used, in the intake entries of each split immediately inby the split point.\n\n(d) The person conducting the preshift examination shall check the refuge alternative for damage, the integrity of the tamper-evident seal and the mechanisms required to deploy the refuge alternative, and the ready availability of compressed oxygen and air.\n\n(e) The district manager may require the operator to examine other areas of the mine or examine for other hazards and violations of other mandatory health or safety standards found during the preshift examination.\n\n(f) Certification. At each working place examined, the person doing the preshift examination shall certify by initials, date, and the time, that the examination was made. In areas required to be examined outby a working section, the certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(g) Recordkeeping. A record of the results of each preshift examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards and their locations found by the examiner during each examination, and of the results and locations of air and methane measurements, shall be made on the surface before any persons, other than certified persons conducting examinations required by this subpart, enter any underground area of the mine. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the certified person who made the examination or by a person designated by the operator. If the record is made by someone other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. A record shall also be made by a certified person of the action taken to correct hazardous conditions and violations of mandatory health or safety standards found during the preshift examination. All preshift and corrective action records shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(h) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 62 FR 35085, June 30, 1997; 64 FR 45170, Aug. 19, 1999; 73 FR 80697, Dec. 31, 2008; 77 FR 20714, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1722","heading":"Mechanical equipment guards.","id":"75.1722","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1722","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4608387","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}